Loading...
05-3226 (CONR) Roofing Systemn Belo• consr - 4-FMRfNXE URO - `AST ° Roofing, Inc. Single -ply Roofing. System SYSTEM SPECI FI CATI ONS FOR ARCHITECTS, ENGINEERS, CONTRACTORS AND OWNERS G�.Ssrfi,�o MIAMI•DADE Miami -Dade County, Florida Approved Is ICC -Legacy Report ER 5694 ICC -Legacy Report ER 5694 Copyright 1982, 1983, 1984, 1985, 1986, 1987, 1988, 1989, 1990, 1991, 1992, 1993, 1994, 1995, 1996, 1997; 1999, 2003 By Duro-Last® Roofing, Inc. All Rights Reserved Printed in.the United States of America FM APPROVED 002*6'" C� C COOL ROOF K417nG CUL NUL CMARTGR AtIMBIR 525 Morley Drive Saginaw, MI 48601 r • r tir�WOR��s ' URO. `.AST • sFStIzo Roofing, Inc. 525 Morley Drive Saginaw, MI 48601 Tel: 800-248-0280 Fax: 800-432-9331 Duro-Last® Roofing, Inc. GENERAL SPECIFICATIONS T TABLE OF CONTENTS TABLE OF CONTENTS 1 WELCOME LETTER 2 THE "WORLR'S BEST ROOF.' 3 ,FOREWORD' 4 OETTING STARTED 5 .1. Membrane Description 2. Applicability 3. Tool Requirements .4. Drainage/Slope 5. Weather Considerations 6. Delivery 7. Handling 8. Storage THINGS TO KNOW 6 9. Substrate Separation 10.Chemical Resistance. ' 11. Paint Application DURO-LAST@ 40 MIL SPEC DATA SHEET 7 DURO-LAST@ 50 MIL SPEC DATA SHEET 9 DURO-LASTO 60 MIL SPEC DATA SHEET 11 GENERAL SPECIFICATIONS _ _ February 2003 1 "Uum-L:ui. dtr "��'uiW's ❑si Rout n: dtt ntu r.-1:�5i Ulul±e :ur rccistrirJ maiAs i,t.ned be Durml.ast Kanlim: ha: UROM `AST, • .Roofing, Inc. March 1, 2001 Welcome: 525 Morley Drive Saginaw, Michigan 48601 (989) 753-6486 (800) 248-0280 FAX (989) 753-4472 FAX (800) 432-9331 www.duro-last.com Congratulations on your interest in the Duro-Last Roofing System. This system has been engineered for longevity and cost effectiveness. Custom prefabricated materials prod.uced in our quality -controlled environment can meet the unique requirements of each installation, offering the building owner a top-quality product. Simple and proven installation techniques provide a fast and economical roof assembly. Installation by an authorized contractor as well as a thorough inspection of each completed project assures you that your Duro-Last Roofing System will meet stringent commercial standards. All these factors make the Duro-Last Roofing System the "World's Best Roof'T"'. Duro-Last is one of the largest manufacturers of thermoplastic roofing systems in the United States. Our tremendous growth attests to thesuccess of Duro-Last's prefabricated roofing system. Quality products,, competitive pricing and service make Duro-Last unequaled in the marketplace. If you have, any questions about the Duro-Last Roofing System, please call our staff at one of. the Duro-Last locations. Sincerely, Jack C. Burt Chairman of the Board Duro-Last Roofing, Inc. Other Locations: Grants Pass, Oregon Jackson., Mississippi Sigourney, Iowa 2 Duro -Last® The "WORLD'S BEST ROOD"T" Duro-Last Roofing, Inc., is the pioneer and one of the nation's largest manufacturers of custom prefabricated roofing systems. Every Duro-Last roofing system is prefabricated in one of four Duro-Last manufacturing plants to meet your specific roofing needs. Approximately 80% of the field seams and roughly 95% of the remaining critical areas (projections and perimeters) are welded under ideal factory conditions. The result is a consistent, high quality roofing system designed and manufactured for each building on which it's installed; a concept that renders other roofing systems obsolete. Our standard 40 mil membrane outperforms other roofing products in all critical areas. Duro-Last Roofing,.lnc., warranties are available at no additional cost and we believe are the best in the industry. Commercial projects may be eligible for (at the choice of the building owner) either a 15 -year or 20 - year labor and material warranty. Residential projects receive a separate 15 -year material warranty. The warranty section in this manual covers each warranty in detail. When a commercial roof is completed, a Duro-Last quality assurance specialist will inspect the roof for compliance with the Duro-Last specification. Upon final inspection, acceptance, and payment of all related invoices, Duro-Last will immediately issue the warranty to the Duro-Last contractor. The Duro-Last roofing system meets or exceeds major national fire and wind code requirements as well as most of the regional approvals throughout the country. Duro-Last is approved by Factory Mutual Research Corporation (FMRC), Underwriters Laboratories, Inc. (UL), and the major code agencies; Building Officials & Code Administrators (BOCA), International Conference of Building Officials (ICBO), Southern Building Code Conference International, Inc. (SBCCI), and International Building Code (IBC). Duro-Last participates in the major technical committees in the roofing industry including the American Society of Testing Materials (ASTM), and the Single Ply Roofing Institute (SPRI), Cool Roof Rating Council (CRRC), and the United States Green Building Council (USGBC). In addition, Duro-Last maintains and continually updates a highly sophisticated in-house laboratory for quality control testing for all phases of manufacturing. . Duro-Last and its subsidiary companies employ over 725 people, including 50 who are factory trained quality assurance specialists strategically located throughout the country. In addition, Duro-Last has a network of over 60 sales professionals based throughout North America. As Duro-Last has grown into its position of distinction, several major industrial leaders, corporations and sources of specifications throughout the country have recognized Duro-Last for its technological contributions to the roofing industry. Duro-Last won the "State of Michigan New Product of the Year" award in 1986. Governor Blanchard presented Duro-Last's Founder John R. Burt, with the "Small Businessman -Of -The -Year" award in 1987. In 1991, Burt was honored with the "Entrepreneur of the Year" award for the State of Michigan, and in 1997;1998, he was a finalist for this same award. Also in 1998, Burt received the "Vision of Free Enterprise" award followed by a special award in 1999, recognizing his outstanding contributions to the economy of Saginaw County. Nationally recognized roofing experts have visited the Duro-Last facility, and have stated that its quality control procedures are the best in the roofing industry. Duro-Last's increasing penetration into commercial and institutional sectors has generated "controlled" growth at more than twice the rate of the roofing industry. As a result, Duro-Last has made major capital improvements. and investments towards increased manufacturing capacity, allowing for growth and vertical integration of manufacturing as well as improved quality control of the entire Duro-Last Roofing System. All of this translates into a roofing system that provides the consistent watertight integrity building owners look for. By manufacturing virtually all of the components of the roofing system in its facilities, using rigorous quality -controlled procedures, and by providing the majority of the labor for "building" the roof system in it's factory, Duro-Last minimizes•the liabilities commonly associated with a roofing investment. Furthermore, Duro-Last backs it's claims by offering the most comprehensive warranty coverage in the industry. In short, Duro-Last Roofing, Inc. is committed to the roofing industry. Duro-Last has earned the respect of the roofing and business communities -throughout North America and has assumed a leading role in roofing manufacturing technology. Duro-Last looks forward to providing the best solution to your roofing needs. 3 GENERAL SPECIFICATIONS _ _ Febm 2003 0 FOREWORD The main •purpose of this manual is to create a better understanding of specifications and conditions for the installation of the Duro-LastO Roofing System. There are literally hundreds, if not thousands; of different •, installation details, and not all can be covered*. However, with a basic understanding, you will be able to. accommodate almost any situation. Should you have any questions, do not hesitate to call Duro-Last at 800- 248-0280. This manual does not attempt to make judgments on whether or not an existing roof system should be removed. Nor does this manual make structural judgments for weight considerations. Use this manual as a guide for installing the Duro-Last Roofing System. It will prove itself invaluable in achieving an installation that will provide top-notch performance, security, and longevity for the building owner. NOTES 1.. The Duro-Last contractor is responsible for following all applicable building, plumbing and electrical codes. 2. The Duro--Last contractor is responsible for taking core cuts and conducting pullout tests. These tests will be used to determine fastener type and length as.well as to determine the condition of the existing roof deck and presence of water in the existing roof system. 3. Duro-Last does not approve the practice of roofing over existing roof systems that contain excess moisture. This includes water that flows into openings created by core cuts or water that is obtained by squeezing the core sample taken from the existing roof system. Any decision to recover a roof with excessive moisture is the sole responsibility of both the installer and the building owner, and may affect or limit warranty coverage. 4. The Duro-Last contractor is responsible for standard roofing practices, proper safety procedures, and compliance with OSHA, as well as all state, local and other safety rules, regulations, and codes. It is the responsibility of the roofing contractor to obtain any project building permits and insurance necessary that are above and beyond those Duro-Last-may require. 5. The Duro-Last contractor assumes the responsibility to assure that the installed system meets or exceeds all project specifications. The Duro-Last Roofing System is Underwriters Laboratory classified and Factory Mutual Research approved. For these and other special conditions, consult the DURO-LAST ENGINEERING SERVICES DEPARTMENT at 800-248-0280. 6. Duro-Last Roofing, Inc. is not responsible for any alterations to a roofing system (new or existing) which may change the thermal characteristics or dew point of the roofing assembly. 7. The sole purpose of the Duro-Last warranty inspection process is to determine the proper application of the Duro-Last,Roofing System. This inspection in no way extends to adjacent building components or other areas the Duro-Last inspector may come in contact with, including but not limited to, structural defects, architectural design or modifications made to the building by the installing contractor. The Duro-Last inspector does not promote himself as knowledgeable about roofing or construction practices other than the proper application of the Duro-Last Roofing System. The ultimate goal of {he'inspection process is to determine general compliance with these specifications and the overall watertight integrity of the roof.system. s GENERAL SPECIFICATIONS , ._ February 2003 4 GETTING STARTED 1. MEMBRANE DESCRIPTION A. The membrane is comprised of a polyvinyl chloride polymer blend, which is reinforced with a high strength, 18 x 14 threads per inch pattern, weft inserted polyester scrim. The membrane contains a combination of UV stabilizers, UV absorbers, plasticizers, heat stabilizers, flame retardant, lubricants and biocides, and shall exhibit the minimum physical properties as listed on the Physical Properties Data in the General Section. B. The .040 -inch (1 -mm) thick Duro-Last single -ply roof membrane has a roll goods weight of approximately 0.25 Ib/ft2 (1.3 Kg/m2). The prefabricated roof cover is supplied folded or rolled; in sections up to 2,500 square feet (232 square meters) in area, and having no single linear dimension exceeding 100 feet (30.5-m). 0 C. The .050 -inch (1.25 -mm) thick Duro-Last single -ply roof membrane has a roll goods weight of approximately 0.35 Ib/ft2 (1.4 Kg/m2). The prefabricated roof cover is supplied folded or rolled, in sections up to 2,000 square feet (185 square meters) in area, and having no single linear dimension exceeding 80 feet (25.4 m). 2. APPLICABILITY The Duro-Last Roofing System consists of the Duro-Last membrane, fasteners, prefabricated corners, parapets, stacks, curb flashings, vents, and other related Duro-Last-,approved products necessary for the proper and warrantable installation of the Duro-Last Roofing System. All materials used in the installation of the Duro-Last Roofing System must be products of Duro-Last Roofing, Inc., or accepted products as defined .and described in the specifications. Alternate materials must be accepted in writing by the Duro-Last Engineering Services Department prior to their use with the Duro-Last Roofing System. 3. TOOL REQUIREMENTS The authorized Duro-Last contractor should have the following tools which are necessary for the efficient and proper installation of the Duro-Last Roofing System. A. Hand welders (hot air) with.a spare heating element (Optional: Automatic welder) B. Silicone hand roller C. Variable speed power screw driver with reverse' D. Electric Hamme,r,Drill E. P-3 screwdriver tips for screws F.' R-3 square drive tips for concrete screws G. Hammer drill with.depth gauge H. Measuring tapes (100' and 25') (30 m and 7.5 m), chalk line, markers, lumber crayon I. Metal snips, hacksaw, keyhole saw, hammers, scissors, utility knives with retractable blades J. Vise clamps, nail aprons, caulk gun, screw drivers K. Detergent based cleaning fluid and rags L. 2" (50 -mm) flat chisels, pry bar M. Ladders N. Tack claw O. GriPull P. Tarps " Q. Pull tester R. Panduit Bander S. Extension cords - cord length of 100' (30 m), #12/3 wire w/ground T. Core cutter U. Ground fault interrupter V. Equipment necessary to raise materials to the rooftop 4. DRAINAGE/SLOPE Duro-Last Roofing, Inc. will warrant its membrane in ponding water situations. Duro-Last has found no adverse effects on its membrane because of a lack of positive drainage in a structure'. Although Duro-Last does not require positive drainage, good roofing. practices incorporate the use of positive drainage for the safety of the structure. GENERAL SPECIFICATIONSFebruary 2003. 5 5. WEATHER CONSIDERATIONS The Duro-Last, membrane is designed to perform in all types of weather. The Duro-Last membrane is regularly subjected to DSET EMMAQUA Exposure (ASTM E-838) and low temperature cracking (ASTM D- 2136). (See Physical Propertic3 Data in the General S ) _` !! limited only to the exposure limitations of the installers. It is Duro-Last's recorn rendation „ --.t insi-:i.a.;c; ;- performed within the temperature range of —15°F (-26°C) to 11 YF (46°C). 6. DELIVERY A complete Duro-Last Roofing System and related materials can be delivered in the original packaging and with shipping labels intact. Containers will be labeled with manufacturer's/supplier's name, product name and identification. Each shipment should b.e checked for damages and/or shortages. The freight agent must note damaged materials and/or shortages on the freight bill. Concealed damage must be reported to the freight agent immediately. Materials damaged in shipping, handling or storage cannot be used. 7. HANDLING Once the Duro-Last Roofing System is delivered to the job site: the contractor and cc: tractors crev'I =re responsible for all handling and installation of the roofing system. Adei;uate personnel aril equipment should ;be available to safely iift and place the Duro-Last Roo' ing System onto the rooftop. Folded or rolled prefabricated sections of membrane must be placed on the roof near load-bearing members and in a manner convenient to final placement. • t £3. STORAGE - Duro-Last materials should never be stored in ponding water or where the water runs off higher elevations and onto the materials. THINGS TO KNOW 9. SUBSTRATE SEPARATION The Duro-Last membrane is defect -free when it leaves the factory. Certain substrates are not compatible ,with the Duro-Last membrane and may cause premature failure of the membrane. Over the substrates listed below, install a minimum 3 -mil polyethylene or polypropylene slipsheet prior to the installation of the Duro- Last membrane. Acrylic Coatings Extruded Polystyrene Modified Bitumen Shingles Aluminum Coated Asphalt Granulated Cap Sheet Old Duro-Last Roofs Smooth Asphalt Coated Smooth Asphalt Hypalon (CSPE)• Polyurethane Sprayed Urethane Foam Expanded Polystyrene Mineral Surfaced Cap Coal Tar Pitch PVC/CPA Membranes The Duro-Last membrane is compatible with the following substrates and no separation is required. CPE Roofing Glass Fiber Board Gypsum and DensDeck Cellular Glass Boards Pre -stressed Concrete Decks Polyisoc'yanurate Boards EPDM Lightweight\Structural Concrete Decks (Smooth) Wood Decks 10. CHEMICAL RESISTANCE Duro-Last is resistant to the chemicals listed below. If any other chemicals are present on a particular roof, please contact the Engineering Services Department at Duro-Last Roofing, Inc. at 800-248-0280. Acrylic Paint " Linseed Oil Copper Sulfate Lard (Animal Fats) Detergent Solution Masonry Cleaner Ferric Chloride Phosphoric Acid Fertilizer Solution Muriatic Acid, Fiberglass Mat Polypropylene Fruit Juice . Oleic Acid Furnace Residue Zinc Chloride Hydrogen Peroxide Sodium Hydroxide Latex Paint 11. PAINT APPLICATION The Duro-Last membrane may be painted, but not the vinyl edging. See Chemical Resistance for approved paint types for the membrane. If prohibited painting does cause damage to the edgings, Duro-Last ' Roofing, Inc. is not responsible under the warranty. Should you have any questions, please contact the Duro- Last Quality Assurance Department at 800-248-0280. GENERAL SPECIFICATIONS February 2003 6 (D Z FL O O CC W Z Q of m 2i W 2 E N T 0) r 0 0 T n_ a, m C co U � � foo O O N N aim oLLro o 0 m � ai o -a E a, C1 U) �� 0 — 0 1. PRODUCT NAME Duro-Last Specially Formulated Roofing Membrane 2. MANUFACTURER Saginaw, MI 48601 Phone: (989) 753-6486 (800)248-0280 Fax: (800)432-9331 Branch Offices Grants Pass, OR Phone: (800) 356 6646 Fax: (800)566-2698 Jackson, MS Phone: (800) 434-3876 Fax: (800)566-4478 Sigourney, IA Phone: (888) 500-257= Fax; (888)501-3574 3. PRODUCT DESCRIPTION Basic Use: The Duro-Last Single - Ply Roofing System is a prefabricated waterproofing system used in the following applications: • Re-cover over existing systems • New construction • Both combustible and noncombustible decks Limitations: Duro-Last membrane must not be installed over assemblies with saturated under- lying insulation or directly over existing incompatible roofs without proper separation. Composition and Materials: Duro-Last membrane is a proprietary thermoplastic formulation consisting of resins, plasticizers, stabilizers, fungicides, flame -retardants, and U.V. absorbers, which is laminated to a weft -inserted polyester fabric. It.is available in white, tan, and gray. Sizes: For ease of handling and reduced field seams and installation time, Duro-Last Roofing, Inc. factory welds material in large sheets up to 2,500 square feet (230 square meters) as specified by architects, contractors, or installers. The system weighs .25 lbs. per square foot. Accessory Components: Duro- Last Roofing, Inc. produces a complete line of standard and custom fabricated accessories. These accessories are made from the same material as the deck membrane and are made in a Duro- Last factory, not on the roof. Standard Accessories: Round pipe flashings from 1" (2.5 cm) to 15" (38 cm) in diameter, inside and outside corners, two-way roof vents, roof drain liners, gravel/water stop with factory welded Duro-Last skirts, termination bar, and fascia with cover and joint clips. Custom Made Accessories: scuppers and curbs for all types c i roof penetrations. (For example: HVAC units. skylights, chimneys, etc.) If there is a need for a custom flashing that has not been mentioned, send in a drawing and, if it can be made, Duro-Last will make Applicable Standards: Underwriters Laboratories, Inc., Class A, B, and C (R-101128); Factory Mutual Research Class 1- 60, 1-90, 1-105. 1-150, 1-210: i'aiarr.-D: _ a Ft ; Cit -of Las Angeles, CA: Cita or Deriver, CO; HUD Material Release 1223; City of New York, NY 421-90-M and 422- 90-M; IBC: ICC Legacy Reports (NER-227) -ICBO (ER -5694). 4. TECHNICAL DATA Please refer to page 2 for physical properties and test results. 5. INSTALLATION Duro-Last Roofing, Inc. provides detailed application instructions and training for roofing contractors and consulting services to architects, engineers, and specifiers. The following are general instructions for installing the Duro-Last Roofing System. Deck Surface Preparation: The substrate on which Duro-Last membrane is to be applied must be clean, smooth, free of sharp edges, loose debris, and standing water. Gravel should be leveled. All surface preparations must be done in strict accordance with the Dilro- Last application specifications. Insulation: Insulation must be laid on the deck and cut neatly around all penetrations. It must then be mechanically -attached with approved fasteners according to the Duro-Last specifications. Do not lay. more insulation than can be covered in the same day. Stagger the insulation boards 50% from row to row. Placement: Using the roof layout diagram, select the proper marked and rolled premanufactured sheet of Duro-Last membrane. Orient the membrane so the fastening tabs are perpendicular to the ribs or corrugations of steel deck, or to the width of prestressed concrete "T slabs. Secure the membrane to the roof deck through the fastening tab SPEC4 This Spec -Data sheet conforms to editorial style prescribed by The Construction specifications Institute. The manufacturer is responsible for with approved fasteners and plates, in accordance with Duro-Last specifications. Unfold the sheet, thus covering the fastening tab. Continue unfolding until the next fastening tab appears. Fasten this tab to the deck and repeat the above process until the complete sheet is installed. Penetrations: During the aforementioned procedure, make c!.Itouts in the membrane for I;Ir;iri,. Ui,s. t aal-En L;rJi;IIU CUIUUta vriih DUrv•Last approved fasteners. The skirt of the factory -fabricated accessories when welded to the deck membrane will cover these cutouts. Breather Vents: One Duro-Last two-way breather vent must be installed for each 1,000 square feet (90 square meters). Duro-Last vents must be installed according to the Duro-Last specifications. Parapet Walls: Duro-Last custom fabricated parapet wall flashings are designed for each individual application. Secure through the fastening tab at the bottom of the -wall using approved fasteners and plates. The factory welded skirt will cover the fasteners when it is heat welded to the deck sheet. 6. AVAILABILITY AND COST The Duro-Last Roofing System is available throughout the United States and Canada through the Duro-Last dealer/contractor network and area representatives. For pricing information, contact Duro- Last Roofing, Inc. for the nearest 'Duro-Last sales representative. 7. COMMERCIAL WARRANTIES Upon the successful completion of a final inspection by a Duro-Last quality assurance specialist, Duro- Last Roofing, Inc. will furnish to the Duro-Last contractor either a 15 - year or 20 -year warranty. The 15 -year warranty covers material and labor for repair or replacement for the full 15 years. The 20 -year warranty covers both material and labor for repair or replacement for the first 10 years. The second 10 years is prorated and covers material only. 07500 DURO-LAST PHYSICAL PROPERTIES AS OUTLINED BY AS T iM D-4434 TEST DESCRIPTION TEST METHOD 111�T^. ^ 77 - .'.TS ENC' Thickness, Nominal ASTM D-751 1 mm 40 mils – Type IV Weight ASTM D-751 1.1 kg per m2. ( 0.25 lbs. per sq. ft. Trapezoidal Tear Strength, Min. ASTM D-5587 578 x 498 N 130 x 172 Ibf. Breaking Strength, Min. ASTM D-751 - 1935 x 1557 N 435 x 350 Ibf. Tensile Strength ASTM D-751, ASTM -D882 506 K/cm2 7200 PSI EMMAQUA Exposure ASTM G90, Desert Sun 339,790,M/J/m' -8.1 million langleys Heat Aging ASTM D-3045 (7 days @ 194°F) Retains 90% of Breaking Strength, >95% of elongation I Elongation Dimensional Stability (;'+S'firl D-751 I 25% ASTM D-1204, 80° C, 6 hrs. < 0.05% Low Temperature Flexibility ASTM D-2136, 3 mm Mandrel No Cracks -40° C No Cracks -40° F Dynamic Puncture Resistance 'ASTM D-5635 20 J 474 PDL -FT Static Puncture Resistance ASTM D-5602 >533 N >120 PSF Moisture Vapor Transmission ASTM E-96, Proc. B, Method A < 0.086 g/hr/mZ < 0.25 U.S. Perms Fungi Resistance ASTM G-21 No sustained growth or discoloration Factory Mutual Research ASTM E-108; FM 4450 & FM 4470 Class 1-60, 1-90, 1-105, 1-150 & 1-210 Underwriters Laboratories UL -790 Class A, B & C Solar Reflectance ASTM C1549 88% Thermal Emitlance, ASTM C1371-98 87% 0 07500 8. MAINTENANCE contractors for specifying and detailed Technical field service is also available Keep the finished roof free of debris. installation of the Duro-Last Roofing through Duro-Last field quality Do not use roof area for storage. No System for various field applications, assurance specialists. other maintenance is required. Technical brochures, manuals, and specifications are available upon 10. FILING SYSTEM 9. TECHNICAL SERVICES request. '• Sweets General Building File Duro-Last Roofing, Inc. provides a' 07500/DUR — Buyline 2998 consulting and design service to architects, engineers, and licensed 07500 0 Z O O Of W Z Q _m G' W U) E U) 0 0 T a a) V. c �n U:;:� Coo 00 N N c ( ` 0 LL m 0 � c in c� J N o a aU E ❑ n c 1. PRODUCT NAME Duro-Last" Specially Formulal.;d Roofing Membrane 2. MANUFACTURER C.:ro-Last R. - 525 c525 Morley Drive Saginaw, MI 48601, Phone: (989) 753-6486 (800)248-0280 Fax: , (800) 432-9331 Branch Offices Grants Pass, OR Phone: (800) 356-6646 Fax: (800)566-2698 Jackson, MS Phone: (800) 434-3876 Fax: . (800) 566-4478 Sigourney, IA• Phone: (888) 500-3574 Fax: • (888) 501-3574 3: PRODUCT DESCRIPTION Basic Use: The Duro-Last Single - Ply Roofing System is a prefabricated' waterproofing system used in the following applications: • Re-cover over existing systems • New construction • Both combustible and noncombustible decks Limitations: Duro-Last membrane must not be installed over assemblies with saturated under- lying insulation or directly over existing incompatible roofs without proper separation. ' . Composition and Materials: Duro-Last membrane is a proprietary thermoplastic formulation consisting of resins, plasticizers, stabilizers, fungicides, flame retardant, and U.V. absorbers, which is laminated to a weft -inserted polyester fabric. It is available in white, tan, and gray. Sizes: For ease of handling and reduced field seams and installation time, Duro-Last Roofing, Inc. factory welds material in large sheets up to 2,000 square feet (185 square meters) as specified by architects, contractors, or installers. The system weighs .35 lbs. per square foot. Accessory Components: Duro- Last Roofing, Inc. produces a complete line of standard and custom fabricated accessories. These accessories are made from the same material as the deck membrane and are made in a Duro- Last factory, not on the roof. Standard Accessories: Round pipe flashings from 1" (2.5 cm) to 15" (38 cm) in diameter, inside and outside corners, two-way roof vents,'roof drain liners, gravel/water stop with'fartory welded Duro-Last '. cover and joint clips. Custom Made Accessories: I-,, • i , , : • - :shings greater til: li t, iii), parapet wait scuppers and curbs for all types of roof penetrations. (For example: HVAC units.. skylights, chimneys, etc.) If there is a need for a custom flashing that has not been mentioned, send in a drawing and, if it can be made. Duro-Last will make it. Applicable Standards: Underwriters Laboratories, Inc., Class A, B, and C (R-101128); Factory Mutual Research Class 1- 60. 1-90, 1-105. 1-150, 1-2.10; Miami -Dade County, FL; City of Los Angeles, CA; City of Denver, CO; HUD Material Release 1223; City of New York, NY 421-90-M and 422- 90-M; IBC: ICC Legacy Reports (i lER-227) -ICBO (ER -5694). 4. TECHNICAL DATA Please refer to page 2 for physical properties and test results. 5. INSTALLATION Duro-Last Roofing, Inc. provides detailed application instructions and training for roofing contractors and consulting services to architects, engineers, and specifiers. The following are general instructions for installing the Duro-Last Roofing System. Deck Surface Preparation: The substrate on which Duro-Last membrane is to be applied must be clean, smooth, free of sharp edges, loose debris, and standing water. Gravel should be leveled. All surface preparations must be done in strict accordance with the Duro- Last application specifications. Insulation:' Insulation must be laid on the deck and cut neatly around all penetrations. It must then be mechanically attached with approved fasteners according to the Duro-Last specifications. Do not lay more insulation than can be covered in the same day. Stagger the insulation boards 50% from row to row. Placement: Using the roof layout diagram, select the proper marked and rolled premanufactured sheet of Duro-Last membrane. Orient the membrane so the fastening tabs are perpendicular to the ribs or corrugations of steel deck, or to the width of prestressed concrete "T` slabs. Secure the membrane to the roof deck through the fastening tab SPECS � with approved fasteners and plates, in accordance with Duro-Last specifications. Unfold the sheet, thus covering the fastening tab. Continue unfolding until the next fastening tab appears. Fasten this tab to the deck and repeat the above process until the complete sheet is installed. Penetrations: During the aforementioned procedure, make CLrtoufs in the membrane for protrusions. Fasten around cutouts v✓ith Duro-Last approved fasteners. The skirt of the factory -fabricated accessories when welded to the clerk /Ill Cover th•?Se CLItOLItS. Breather Vents: One Duro-Last two-way breather vent must be installed for each 90 square meters (1,000 square feet). Duro-Last vents must be installed according to the Duro-Last specifications. Parapet Walls: Duro-Last custom fabricated parapet wall flashings are designed for each individual application. Secure through the fastening tab at the bottom of the wall using approved fasteners and plates. The factory -welded skirt will cover the fasteners when it is heat welded to the deck sheet. 6. AVAILABILITY AND COST The Duro-Last Roofing System is available throughout the United States and Canada through the Duro-Last dealer/contractor network and area representatives. For pricing information, contact Duro- Last Roofing, Inc. for the nearest Duro-Last sales representative. 7. COMMERCIAL WARRANTIES Upon the successful completion of a final inspection by a Duro-Last quality assurance specialist, Duro- Last Roofing, Inc. will furnish to the Duro-Last contractor either a 15 - year or 20 -year warranty. The 15 -year warranty covers material and labor for repair or replacement for the full 15 years. The 20 -year warranty covers both material and labor for repair or replacement for the first 10 years. The second 10 years is prorated and covers material only. 07500 0 DURO-LAST PHYSICAL PROPERTIES ' AS OUTLINED BY ASTM D-4434 TEST D13CRIPTIO(d Thickness, Nominal ASTM D-751 1.25 mm 50 mils — Type III Weight ASTM D-751 1.4 kg per mz. 0.35 lbs. per sq. ft. Trapezoidal Tear Strength, Min. ASTM D-5587 840 x 471 N 106 x 189 Ibf. Breaking Strength, Min. ASTM D-751 2104 x 1748 N 473 x 393 Ibf. Tensile Strength ASTM D-751, ASTM -D882 617 K/anz 8780 PSI EMMAQUA Exposure ASTM G90, Desert Sun 339,790 M/J/m? >8.1 million langleys Heat Aging ASTM D-3045 (7 days @ 194`F) Retains 85% of Breaking Strength, >90% of elongation Elongation ASTM D-751 25% Dimensional Stability ASTM D-1204, 80° C, 6 hrs. < 0.1% Low Temperature Flexibility ASTH D-2136. n mn) NJIindrel No CracHs -4n^ r Static Puncture Resistance ASTM D-5602 >533 N No (Cracks, -em F >120 PSF Moisture Vapor Transmission . ASTM E-96, Proc. B, Method A < 0.07 g/hr/mz < 0.22 U.S. Perms Fungi Resistance ASTM G-21 \ No sustained growth or discoloration Factory Mutual Research ASTM E-108; FM 4450 & FM 4470 Class 1-60, 1-90, 1-105, 1-150 & 1-210 Underwriters Laboratories UL -790 Class A, B & C Solar Reflectance ASTM C1549 88% Thermal Emittance ASTM C1371-98 87% - — -------------- 8. .--.._ _.- -8. MAINTENANCE contractors for specifying and detailed Technical field service is also available Keep the finished roof free of debris. installation of the Duro-Last Roofing through Duro-Last field quality Do not use roof area for storage. No System for various field applications. assurance specialists. other maintenance is required. Technical brochures, manuals, and specifications are available upon 10. FILING SYSTEM 9. TECHNICAL SERVICES request. Sweets General Building File Duro-Last Roofing, Inc. provides a 07500/DUR — Buyline 2998 consulting and design service to architects, engineers, and licensed . 07>00