Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
05-0702 (RC) Title 24
LE 24, REPORT Title 24 Report for: Maxcey'siGrill-=-Home-ofThe Char-br-oiler_(RUN#5) L7 -9_3.05 -Highway 11-1; Building:7,,-Su.ite 0j La Quinta; 'Ca. 92263 V. Project Designer: Francisco Aguilar 3425 North Indian Avenue, Suite#2 Palm Springs, Ca. 92262 760-778-5437 Report Prepared By: Jack LaFontaine Energy Management Service 41- 485 Adams Street, Unit C ' Bermuda Dunes, CA 92201 760-360-4631 Job Number: CITY OF IA -A" 02122005 BUILDING & SAFETY � ETYiDEPT. APPROVES Date: FOONST� N DA 2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft,'LLCr(415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: 02122005 User Number: 5021 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form ENV -1 Certificate of Compliance 3 Form ENV -2 Overall Envelope Method 5 Form LTG -1 Certificate of Compliance) 11 Form LTG -2 Lighting Compliance Summary 14. Form LTG -3 Lighting Controls Credit Worksheet 15 Form LTG -4 Tailored LPD Summary and Worksheet 16 Form LTG -MM Lighting Mandatory Measures 17 Form MECH-1 Certificate of Compliance 18 Form MECH-2 Mechanical Equipment Summary 20 Form MECH-3 Mechanical Ventilation 22 Form MECH-4 Mechanical Sizing and Fan Power 23 1 Form MECH-MM Mechanical Mandatory` Measures 24 HVAC System Heating and Cooling Loads Summary, 26 Room Load Summary 27 Room Heating Peak Loads ; 28 Room Cooling Peak Loads 29 Room Cooling Coil Loads 30 Lighting Inspection Checklist 31 r EnergyPro 3.1 By EnergySoft " Job Number: 02122005 User Number: 5021 CERTIFICATE OF COMPLIANCE Part 1 of 2 ENV -1 PROJECT NAME DATE Maxce 's Grill - Home of The Charbroiler RUN#5 2/14/2005 PROJECT ADDRESS 79-305 Highway 111, Building 7 - Suite 01 La Quinta PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit # Francisco Aguilar 760-778-5437 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Energy Management Service 760-360-4631 1 Enforcement A enc Use GENERAL INFORMATION DATE OF PLANS CONDITIONED FLOOR AREA CLIMATE ZONE 1 /16/2005 JBUILDING 2,700 sy.Fc. 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ❑ ADDITION ❑X ALTERATION EXISTING + ADDITION METHOD OF ENVELOPE ❑ COMPONENT ® OVERALL ENVELOPE PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and, performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the document is accur a an complete. DOCUMENTATION AUTHOR SIG E DATE/ Jack LaFontaine „ �— w The Principal Envelope Designer hereby certifies that thpro osed bui ding design represented in this set of construction documents is consistent with the other compliance forms worksheets, with the specifications, and with. any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in Sections 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6. Please check one: ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to'sign this document as the person responsible for its preparation; and that I am licensed in the state of California as a civil engineer or mechanical engineer, or I am a licensed architect. ) ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type, of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. 0 PRINCIPAL ENVELOPE DESIGNER - NAME SIGNAT DATE Francisco Aguilar e ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ENV -1: Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. . ENV -2: Used for all submittals; choose appropriate version depending on method of envelope compliance. ENV -3: Optional. Use if default U -values are not used. Choose appropriate version for assembly U -value to be calculated. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:3 of 31 1 11 ENVELOPE COMPLIANCE SUMMARY Part 2 of 2 ENVr1 PROJECT NAME Maxce 's Grill - Home of The Charbroiler RUN#5 DATE 2/14/2005 OPAQUE SURFACES SHGC Glazing Type - 1 Surface Framing Act. # Type Type Area U -Fac. Azm. Tilt Solar Gains .y/N Form 3 Reference Location / Comments 1 Roof Wood 2,700 0.035 180 0 X11 I R-30 Roof R.30.2x12.16 Restaurant 2 Wall Metal 473 0.145 0 90 X I I R-19 Metal Stud Wall Restaurant 3 Wall Metal 754 0.145 90 90 X I I R-19 Metal Stud Wall Restaurant 4 Wall Metal 744 0.145 180 90 X I I R-19 Metal Stud Wall Restaurant 5 Door None 21 0.146 180 90 Door, Insulated Metal Restaurant FENESTRATION SURFACES ' Site Assembled Glazing Check box if Building is >= 100,000 sgft of CFA and >=10,000 sgft vertical glazing then NFRC Certification is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form # Type Area JU-Fac. Act. Azm. SHGC Glazing Type Location / Comments 1 Window 250 1.190 0 0.83 Sin le Metal Clear Default. Restaurant 2 Window 42 1.250 0 0.80 Single Metal Clear Default Restaurant 3 Window 245 1.190 90 0.83 Single Metal Clear Default Restaurant 4 Window 21 1.250 90 0.80 Sin le Metal Clear Default Restaurant EXTERIOR SHADING ## Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. Hat. Right Fin Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:4 of 31 i COVERALL ENVELOPE METHOD Part 1 of 6 ENV -2 NAME DATE (PROJECT Maxcey's Grill - Home of The Charbro'Her(RUN#5) 2/14/2005 WINDOW AREA TEST A. DISPLAY PERIMETER 45 ft X 6 = 27 sf DISPLAY AREA B. GROSS EXTERIOR WALL AREA 2,550 sf X 0.40 = 1,02 sf 40% AREA1 C. GROSS EXTERIOR WALL AREA 2,5501 sf X 0.10 = 25 sf. MINIMUM STND. AREA D. ENTER LARGER OF A or B 1 02 sf MAXIMUM STND. AREA E. ENTER PROPOSED WINDOW AREA jrj sf PROPOSED AREA F. WINDOW WALL RATIO = Proposed Window Area Divided by Gross Exterior Wall Area = 21. IF E IS GREATER THAN D OR LESS THAN C, PROCEED TO THE NEXT CALCULATION FOR THE WINDOW AREA ADJUSTMENT. IF NOT, GO TO PART 2 OF 6. 1. IF E GREATER THAN D: MAXIMUM PROPOSED WINDOW STANDARD AREA WINDOW AREA ADJUSTMENT FACTOR GO TO PART 6 TO CALCULATE ADJUSTED AREAS. 2. IF LESS THAN C: MINIMUM PROPOSED WINDOW STANDARD AREA AREA ADJUSTMENT FACTOR GO TO PART 6 TO CALCULATE ADJUSTED AREAS. SKYLIGHT AREA TEST ATRIUM HEIGHT 10 FT IF <= 55 FT IF > 55 FT 0.101 X = 0.05 X 2.7 = 135 , STANDARD % GROSS STANDARD ROOF AREA SKYLIGHT AREA 0 PROPOSED SKYLIGHT AREA IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PART 2 OF 6. 1. IF PROPOSED SKYLIGHT AREA >= STANDARD SKYLIGHT AREA: SKYLIGHT STANDARD SKYLIGHT AREA PROPOSED SKYLIGHT AREA ADJUSTMENT FACTOR GO TO PART 6 TO CALCULATE ADJUSTED AREAS. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page•5 0 31 6 I OVERALL ENVELOPE METHOD I IPart2 of 6 - ENV -2 PROJECT NAME Maxce 's Grill - Home of The Charbroiler F OVERALL HEAT LOSS ,o a a E ASSEMBLY NAME (e.g. Wall -1, Floor -1) Roof W all-Front-N,45'x17' Windows -25'x10' Alu SP Glass Door#D1,Met SP Clear W a I I -Left -Ea st,60'x 17'. Windows -24'6"x10' Alu SP 'Glass Door#D1,Met SP Clear Wall -Rear -S, 45'x17' L ' If Window and/or Skylight Area Adjustment is Required Column E shall be 1,047 This Page Total 786 use Adjusted Areas from Part 6 of 6. no greater than Column H 1,047 Building Total 786 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:6 of 31 DATE 2/14/2005 a a a STANDARD AREA' (Adjusted) U -FACTOR UA (F X G) 2,700 0.057 153.9 473 0.1 82 86.1 250 0.49C 122.5 42 0.49C 20.6 754 0.1814 137.2 245 0.49C 120.1 21 0.49C 10.3 7441 01 135.4 �®soon ' If Window and/or Skylight Area Adjustment is Required Column E shall be 1,047 This Page Total 786 use Adjusted Areas from Part 6 of 6. no greater than Column H 1,047 Building Total 786 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:6 of 31 DATE 2/14/2005 a a a STANDARD AREA' (Adjusted) U -FACTOR UA (F X G) 2,700 0.057 153.9 473 0.1 82 86.1 250 0.49C 122.5 42 0.49C 20.6 754 0.1814 137.2 245 0.49C 120.1 21 0.49C 10.3 7441 0.182 135.4 ' If Window and/or Skylight Area Adjustment is Required Column E shall be 1,047 This Page Total 786 use Adjusted Areas from Part 6 of 6. no greater than Column H 1,047 Building Total 786 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:6 of 31 [OVEkALL ENVELOPE METHOD Part.3 Of 6 ENV -2 PROJECT NAME Maxce 's Grill - Home of The Charbroiler RUN#5 DATE 2/14/2005 OVERALL HEAT GAIN FROM CONDUCTION . 0 00o a a a, o o a PROPOSED STANDARD TABLE HEAT, HEAT ASSEMBLY NAME f HEAT U- VALUES GAIN AREA" U- GAIN (e.g. Wall -1, Floor -1) AREA TF CAPACITY FACTOR Q Y N BxCxE (Adjusted) FACTOR TF (GxHxl Roof 2,700 55 2.73 0.035 [XI ❑ 5,157 2,700 ' 0.057 55 8,464 all-Front-N,45'x17' 473 55 2.80 0.145 ❑ 3,7711 473 0.182 55 1 4,735 Windows -25'x10' Alu SP 250 55 1.190 ❑ © 16,363 250 0.490 55 6,738 Glass Door#D1,Met SP Clear 42 55 1.250 ❑ ® 2,888 42 0.490 55 1,132 all-Left-East,60'x17' 754 55 2.80 0.145 ❑ ® 6,011 754 0.182 55 7,548 Windows -24'6"x10,' Alu SP . 245 55 1.190 ❑ ® 16,035 245 0.490 55 6,603 Glass Door#D1,Met SP Clear 21 55 1.250 ❑ ® 1,444 21 0.490 55 566 Wall -Rear -S, 45'x17' 744 55 2.80 0.145 ❑ ® 5,932 744 0.182 55 7,447 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ I ❑ ❑ ❑ ❑ El El El El El El 1-1 El El El El El El El El El ❑❑ El El El 1:1 El El El El El F-1 F-1 57,600 43,232 Subtotal Subtotal "If Window and/or Skylight Area Adjustment is Required use Adjusted Areas from Part 6 of 6. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:7 of 31 [OVERALL ENVELOPE METHOD Part 4 of 6 . ENV -21 I' PROJECT NAME DATE Maxce 's Grill - Home of The Charbroiler RUN#5 _ 2/14/2005 OVERALL HEAT GAIN FROM RADIATION' OPAQUE SURFACES a a a o o a a o a a a 7,427 12,191 ' SUBTOTAL SUBTOTAL EnergyPro 3.1 By EnergyPro User Number: 5021 Job Number: 02122005 Page:8 of 31 PROPOSED STANDARD ASSEMBLY NAME e.g. Roof -1) AREA SF WEIGHTING FACTOR U- FACTOR Absorp HEAT GAIN (BxCxDxExF) AREA' (ADJUSTED) U -Factor Absorp HEAT GAIN (CxDxHxlxJ) Roof 2.700 123 0.92 0.035 0.70 7,427 2,700 0.057 0.70 12,191 - r - 7,427 12,191 ' SUBTOTAL SUBTOTAL EnergyPro 3.1 By EnergyPro User Number: 5021 Job Number: 02122005 Page:8 of 31 JOVEkALL.ENVELOPE METHOD Part 5 of 6 ENV -2 PROJECT NAME DATE Maxcey's Grill - Home of The Charbroiler(RUN#5) 2/14/2005 ' OVERALL HEAT GAIN FROM RADIATION FENESTRATION SURFACES 0 0 ©oaaaa a o00 r PROPOSED STANDARD INDOW/SKYLIGHT NAME e.g. Wind -1, Sky -1) ORIENT. WEIGHTING FACTOR AREA SF SHG OVERHANG HEATOGAINAREA• (BxCxDxExH) (ADJUSTED) RSHG (or SHGC") SF HEATOGAIN (BxJxKxL) H 'V I HN I OHF Windows -25'x10' Alu SP N 0.61 25C 123 0.83 ' "If Window and/or Skylight Area Adjustment is Required, use 15,569 250 0.47 123 8,816 Glass Door#D1 Met SP Clear N 0.61 42 123 0.80 2,521 42 0.47 123 1,481 Windows -24'6"x10' Alu SP E 1.07 24 123 0.83 Job Number: 02122005 Page:9 of 31 26,763 245. 0.36 123 11,608 Glass Door#D1 Met SP Clear E 1.07 2 123 0.801 2.21 '211 0.36 123 995 r Only SHGC is Part 3 Subtotal, 57,600 Part 43,232 used for Skylights 3 Subtotal ' Part 4 Subtotal 7,427 Part 4 Subtotal 12.19 ' "If Window and/or Skylight Area Adjustment is Required, use Column I must be less than column M Part 5 Subtotal 47,064 Part 5 Subtotal 22,900 Adjusted Areas from Part 6 of 6. ' 112,091 Total Heat Gain 78,323 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:9 of 31 r [OVERALL ENVELOPE METHOD Part 6 of 6 ENV -2 I i' PROJECT NAME DATE Maxce 's Grill - Home of The Charbroiler RUN#5 2/14/2005 I INDOW AREA ADJUSTMENT CALCULATIONS ❑X CHECK IF NOT APPLICABLE (See Part 1 of 6.) RIENTATION ADJUSTED ROOF AREA (8 - E) © D❑ CHECK IF NOT APPLICABLE (See Part 1 of 5.)E❑ WINDOW ADJUST. FACTOR (From Part 1) ADJUSTED WINDOW AREA (D X E) ADWUAS LED AREA B - (F + C) WALL NAME (e.g. Wall -1, Wall -2) GROSS AREA DOOR AREA WINDOW AREA I E I S JW I FN ❑ ❑ ❑ ❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑ El -El ❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑ ❑❑❑ ❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ ❑❑❑❑ N/A ' TOTALS N/A TOTALS EnergyPro 3.1 By EnergySoft User Number 5021 Job Number: 02122005 Page: 10 of 31 © SKYLIGHT AREA ADJUSTMENT CALCULATIONS ADJUSTED SKYLIGHT AREA (C X D) ADJUSTED ROOF AREA (8 - E) GROSS AREA SKYLIGHT AREA CHECK IF NOT APPLICABLE (See Part 1 of 5.)E❑ �F ' ❑A TOTALS EnergyPro 3.1 By EnergySoft User Number 5021 Job Number: 02122005 Page: 10 of 31 © SKYLIGHT ADJUST. FACTOR (From Part 1) ADJUSTED SKYLIGHT AREA (C X D) ADJUSTED ROOF AREA (8 - E) GROSS AREA SKYLIGHT AREA N/A ' CERTIFICATE OF COMPLIANCE Part 1 of 3 LTG -1 PROJECT NAME DATE Mane 's Grill - Home of The Charbroiler RUN#5 2/14/2005 PROJECT ADDRESS 79-305 Highway 111, Building 7_- Suite 01 La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Energy Management Service 760-360-4631 Enforcement A enc Use GENERAL INFORMATION DATE OF PLANSBUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 1/16/2005 2,700 Sq.Ft. 15 BUILDING TYPE _ ® NONRESIDENTIAL HIGH RISE RESIDENTIAL E] HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ® ALTERATION ❑ EXISTING + ADDITION METHOD OF LIGHTING COMPLETE BUILDING ® AREA CATEGORY ❑ TAILORED PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is cc ate and complete. DOCUMENTATION AUTHOR SI RDATE Jack LaFontaine , -/y�0 posed building design represented in this set of construction The Principal Lighting Designer hereby certifies that thedr documents is consistent with the other compliance formsd worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146 or 149 of Title 24, Part 6. Please check one: I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE LIC. # LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance orms, please re er to the Nonresidential Manual published by the California Energy Commission. LTG -1: Required on plans for all submittals..Part 2 and 3 may be incorporated in schedules on plans. LTG -2: Required on all submittals. LTG -3: Optional. Use'only if lighting control credits are taken. LTG -4: Optional. Use only if Tailored method is used. LTG -5:, Optional. Use only if Tailored method is used. EnergyPro 3.1 By EnergySoft User Number 5021 Job Number: 02122005 Page:11 of 31 , .. f LIGHTING COMPLIANCE SUMMARY Part 2 of 3 LTG -1 PROJECT NAME DATE Maxcey's Grill - Home of The Charbroiler(RUN#5) 2/14/2005 INSTALLED LIGHTING SCHEDULE I AReoc I 0Ar r Acre II Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTIONer # Watts Lamp DESCRIPTION # Lam + Ballast' Total Watts # Watts 8 2 2 ft Fluorescent T8 Elec F17T8 2 17 Electronic 1. 4 33.0 132 9 (3) 4 ft Fluorescent T8 Elec F32T8 3 321 Electronic 1. 32 93.0 2,976 9a 2 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1. 41 62.0 248 Automatic Time Switch 9 32 NOTES TO FIELD - For Building Department Use Only Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 3,356 Meets Total 3,356 ❑ Efficacy and Control Requirement of §130(c) Portable Lighting (From LTG -1) Less Control Credit Watts (From LTG -3) 155 ❑ Control Requirements of §131(f) Adjusted Actual Watts 3,201 MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION t CONTROL TYPE (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED NOTE TO FIELD CONTROLS FOR CREDIT CONTROL LOCATION (Room # or Dwg. #) CONTROL IDENTIFICATION CONTROL TYPE (Occupant, Daylight, Dimming, etc.) UMIN CONTROLLED NOTE TO FIELD TYPE 1# OF LUMINAIRES Restaurant Automatic Time Switch 8 4 Restaurant Automatic Time Switch 9 32 NOTES TO FIELD - For Building Department Use Only L -nciyyriu o. 1 Dy anergyouR user Numoer. ouzi Job Number 02122005 Page: 12 of 31 1 LIGHTING COMPLIANCE SUMMARY Part 3 of 3 LTG -1 ' PROJECT NAME DATE Maxce 's Grill - Home of The Charbroiler RUN#5 " 2/14/2005 TABLE 1A - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET ❑ h ROOM # DEFAULT AREA TOTAL WATTS OR ZONE ID W/s ft SF B X C 1 J ' TOTAL 0 0 TABLE 1e - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET TOTAL AREA (SF) FA] o 0 o a a o ' LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID n.—im;.. FIXT FIXTI IRF IRF% AREAS in . F% Ir ., r=% Restaurant 2,700 1 2,700 TOTAL 2 700 0 TABLE 1C - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # OR ZONE ID TOTAL AREA (SF) Designer needs to provide detailed documentation that the lighting i level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 2,700 0 - r EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page 13 of 31 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LIGHTING COMPLIANCE SUMMARY LTG -2 PROJECT NAME DATE Maxce 's Grill - Home of The Charbroiler(RUN#5) 2/14/2005 LUMINAIRE NAME 8 9 9a (2) 2 ft Fluorescent T8 Elec (3) 4 ft Fluorescent T8 Elec 2) 4 ft Fluorescent T8 Elec NUMBER OF LUMINAIRES 4 32 4 WATTS PER LUMINAIRE (Including Ballast CEC DEFAULT Y N' 33.0 ❑ ® ❑ ❑ ❑❑ El El ❑❑. ❑❑ OF ❑❑ ❑❑ 93.0 62.0X❑ BUILDING CATEGORY (From Table 1-M) WATTS COMPLETE ALLOWED Total Watts 132 2,976 248 Subtotal from this Page 3,356 Building Total 3,356 Portable Lighting (From LTG -1) Less Control Credit Wafts (From LTG -3) 155 Adjusted Actual wafts 3 201 COMPLETE BUILDING METHOD BUILDING CATEGORY (From Table 1-M) WATTS COMPLETE ALLOWED PER SF BLDG. AREA WATTS AREA CATEGORY METHOD AREA CATEGORY (From Table 1-N) WATTS AREA ALLOWED PER SF (SF) WATTS Comp Bldg Restaurant 1.20 2,700 3,240 PAGE TOTAL 2 7OO 3,2401 BUILDING TOTAL 2 700 3,2401 AREA WATTS TOTAL ALLOWED WATTS (From LTG -4 or from computer run.l L EnergyPro 3.1 By EnergySoft User Number 5021 Job Number: 02122005 c Page:14 of 31 1 l t ILIGHTING CONTROL CREDIT WORKSHEET LTG -3 PROJECT NAME Mane 's Grill - Home of The Charbroiler RUN#5 DATE 2/14/2005 , WORKSHEET F -Al a © o o a © o PLANS REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR CONTROL CREDIT WATTS GXH ROOM # ZONE ID LIGHTING CONTROL DESCRIPTION ROOM RATIO* GLAZING VLT Restaurant Automatic Time Switc g 2-170-0 132 ' 0.05 7 Restaurant Automatic Time Switch g 2,700 2,976 0.05 149 Enter on LTG -1 PAGE BUILDING and 2: Actual Lighting TOTAL TOTAL Power 155 • For windows, use For skylights, use the Window Wall Ratio for the Skylight -to -Roof ratio the room. for the room. 155 calculation. EnergyPro 3.1 By EnergySoft User Number 5021 Job Number: 02122005 Page: 15 of 31 1 k �AICORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 PROJECT NAMEDATE Mane 's Grill - Home of The Charbroiler RUN#5 2/14/2005 1. Watts for Illuminance Categories A -D (from column G) Q wars 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) Q watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) , 01+ 1 0 + 0 = 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) > 0 watts TAILORED LPD - Illuminance Categories A B C and D and Gross Sales Area o a a a o a ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA - ALLOWED LPD ALLOWED WATTS (E x F) Restaurant A 1.07 0 0.20 0 r BUILDING PAGE TOTAL TOTAL jo 01 2,7 C_01 SF WATTS EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page: 16 of 31 [LIGHTING MANDATORY MEASURES' LTG - 11 PROJECT NAME Grill - Home of The Charbroiler(RUN#5 DATE 2/1 DESCRIPTION Designer Enforcement ❑X § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. ` X❑ § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch In sight of the lights. The area of override is not to exceed. 5,000 square feet. 1 X❑ § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. X❑ § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the -Directory. All installed fixtures shall be certified. ❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: 'All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. ❑ § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight In the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously `Diagram shaded by a building on the adjacent lot. of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay In the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. 1 EnergyPro 3.1 By EnergySoft User Number: 5021 ' Job Number: 02122005 Page:17 of 31 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CERTIFICATE OF COMPLIANCE Part Vof 2 MECH-1 PROJECT NAME Maxce 's Grill - Home of The Charbroiler RUN#5 DATE 2/14/2005 PROJECT ADDRESS 79-305 Highway' 111, Building 7 - Suite 01 La Quinta CLIMATE ZONE 1/16/20051 PRINCIPAL DESIGNER - MECHANICAL J TELEPHONE ' Building Permit #' DOCUMENTATION AUTHOR Energy Management Service TELEPHONE 760-360-4631 Checked by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 1/16/20051 2,700 Sq.Ft. 15 BUILDING TYPE ® NONRESIDENTIAL ❑ . HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM, PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION[X] ALTERATION ❑ EXISTING +ADDITION METHOD OF MECHANICAL ® PRESCRIPTIVE ❑ PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the. building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the doc n tion isc ate and complete. DOCUMENTATION AUTHOR SI EDATE Jack LaFontaine The Principal Mechanical Designer hereby certifies that the ropo d buil ing design represented in this set of construction documents is consistent with the other compliance formskWd worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in Sections 110 through115, 120 through 124, 140 through 142, 144 and 145. Please check one: - ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, or mechanical engineer or I am a licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2'or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. , ' ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE DATE LIC. # MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. MECH-1: Required on plans for all submittals. Parts 2 may be incorporated in schedules on plans. MECH-2: Required for all submittals, but may be incorporated in schedules on plans. ' MECH-3: Required for all submittals unless required outdoor ventilation rates and airflows are shown on plans per Section 4.3.4. MECH-4: Required for Prescriptive submittals. MECH-5: Optional. Performance use only for mechanical distribution summary. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:18 of 31 '' P [CERTIFICATE OF COMPLIANCE Part 2 of 2 MECH-1 ' PROJECT NAME Mane 's Grill - Home of The Charbroiler RUN#5 DATE 2/14/2005 SYSTEM FEATURES MECHANICAL SYSTEMS SYSTEM NAME DH W Heater HVAC Rooftop Pkg Units (3) 1 NOTE TO FIELD TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC'HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Gas Fired 76% n/a n/a RHEEM RHGPRO 100-75 Yes Yes n/a n/a n/a n/a n/a Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem Constant Temp n/a Air Balance Auto Diff. Enth (integrated) 735 cfm Gas Furnace 79% AFUE Packaged DX 11.5 EER YORK DH078N/N102AAA3A Yes Yes Ducts in Conditioned n/a Ducts in Conditioned' n/a No ' CODE TABLES: Enter code from table below into columns above. ' ' ' ' ' NOTES HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144e3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? S SEALED DUCTS IN CEILING/ROOF SPACE TO FIELD - For Build*ng Department Use Only r ' CODE TABLES: Enter code from table below into columns above. ' ' ' ' ' NOTES HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144e3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? S SEALED DUCTS IN CEILING/ROOF SPACE TO FIELD - For Build*ng Department Use Only EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page: 19 of 31 ,t MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH7-2 PROJECT NAME Maxce 's Grill - Home of The Charbroiler RUN#5 DATE 2/14/2005 CHILLER AND TOWER SUMMARY CFM Efficiency Tons PUMPS RETURN FAN Equipment Name Equipment Type I Qty. Tot. Qty JGPM Draw -Through BHP Motor . Eff. Drive Eff. Pump Control Motor Drive YORK 1 - • 1DHW /BOILER SUMMARY" Energy Factor or Recovery Efficiency Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input I (Gals.) Vol. Ext. R -Val. RHEEM RHGPRO 100-75 Small Gas Standard 1 75,000 100 0.48 n/a 12 CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty. Output Aux. kW Eff. Output Sensible Efficiency Economizer Type YORK DH078N/N102AAA3A Packa ed DX 9 3 96,000 0.0 79%AFUE 75,000 52,50011.5 EER Diff. Enth (Integrated) CENTRAL SYSTEM FAN SUMMARY Motor Location CFM BHP UPPLY FAN RETURN FAN System Name Fan Type DH078N/N102AAA3A Constant Volume Draw -Through Motor Drive 84.0% 97.0% Motor Drive YORK 1 - • � EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:20 of 31 Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff. DH078N/N102AAA3A Constant Volume Draw -Through 2,600 1.50 84.0% 97.0% none 1 - • � EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:20 of 31 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME Maxce 's Grill - Home of The Charbroiler RUN#5- DATE 2/14/2005 ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL FAN BASEBOARD Min. CFM Reheat Coil Motor Drive Zone Name System Type Qty. Ratio Type DeltaT CFM BHP Eff. Eff. Type Output i EXHAU I I I I II I � II 3.1 By EnergySoft User Number: Job Number: 02122005 Room Name Qty. ` CFM BHP Motor Eff. Drive I Eff. Room Name city. CFM BHP Motor Eff. Drive Eff. J _ 3.1 By EnergySoft User Number: Job Number: 02122005 MECHANICAL VENTILATION MECH-31 ' PROJECT NAME DATE Mane 's Grill - Home of The Charbroiler RUN#5 2/14/2005 ' MECHANICAL VENTILATION FX] ©© o a o© o a, a s ' ZONE/SYSTEM ' Restaurant HVAC Rooftop Pkg Units (3) REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS FER AIR 1,026 735 291 1,026 735 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:22 of 31 MECHANICAL SIZING AND FAN POWER MECH-4 PROJECT NAME DATE . Maxce 's Grill --Horne of The Charbroiler RUN#5 2/14/2005 SYSTEM NAME HVAC Rooftop Pkg Units (3)` FLOOR AREA 2,700 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: COOLING HEATING - OUTDOOR DRY BULB TEMPERATURE (APPENDIX C) 1 1 °F 32 OF - OUTDOOR WET BULB TEMPERATURE (APPENDIX C) 78 OF - INDOOR, DRY BULB TEMPERATURE SEE ASHRAE CHAPTER 8, 1993 78 °F 70 °F OR APPENDIX B 1 2. SIZING: ' - DESIGN OUTDOOR AIR - ROOM LOADS - RETURN VENTED LIGHTING ' - RETURN AIR DUCTS RETURN FAN ' - SUPPLY FAN - SUPPLY DUCTS 735 CFM (MECH 3; COLUMN 1) 26,119 98,812 _ 0 4,94 0 0 4,94 TOTALS 134,867 SAFETY/ WARM-UP FACTOR 1.21 MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY / WARM-UP FACTOR) 163,189 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) 142,642 Btu / Hr IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN 0 FAN DESCRIPTION Supply Fan DESIGN BRAKE HP 1.500 a; a EFFICIENCY MOTOR DRIVE 84.0% 97.0% FE] a NUMBER OF FANS 3.0 29,497 46.138 n/ 2,30 0 0 2,30 80,249 1.43 114,756 288,000 Btu / Hr CFM (Supply Fans) 7,800 120 7 800 NOTE: Include only fan systems exceeding 25 HP (see Section 144). TOTALS 4 Total Fan System Power Demand may not exceed 0.8 Watts/cfm for TOTAL FAN SYSTEM constant volume systems or 1.25 Watts/cfm for VAV systems. POWER DEMAND 0.528 WATTS / CFM Col. F / Col. G EnergyPro 3.1 By EnergySoft User Number 5021 Job Number: 02122005 Page:23 of 31 N IMEC'HANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Maxce 's Grill - Home of The Charbroiler RUN#5 2/14/2005 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established In the Appliance Efficiency Regulations will comply with the applicable standard. X❑ § 115(a) Fan type central furnaces shall not have a pilot light. XJ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X❑ § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: X❑ § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different -schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours If power Is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. - X] § 122(e)2 Each space conditioning system shall be Installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(8) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be - provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other Isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X § 122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. r r] § 112(b) Heat pumps shall be Installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:24 of 31 r IMECiHANICAL MANDATORY MEASURES RES Part 2 of 2 MECH-MM i PROJECT,NAME Max( Grill - Home of The Charbroiler(RUN#5 • DATE 2/14/2005 Description Designer Enforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. X] § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or 1 § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall\be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or X- § 121(f)4 Another method approved by the Commission. i Service Water Heating Systems § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. X] § 113(b)3B Lavatories in restrooms'of public facilities shall be equipped with controls to limit the ` outlet temperature to 110 degrees F. X❑ § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating.system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). . Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). ' EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page: 25 of 31 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAMEDATE Mane 's Grill - Home of The Charbroiler RUN#5 2/14/2005 SYSTEM.NAME FLOOR AREA HVAC Rooftop Pkq Units 3 2,700 ' ENGINEERING CHECKS SYSTEM LOAD Number of Systems 3 Heating System Output per System 96,000 Total Output (Btuh) 288,000 Output (Btuh/sqft) 106.7 Cooling System . Output per System 75,000 Total Output (Btuh) 225,000 Total Output (Tons) 18.8 Total Output (Btuh/sqft) 83.3 Total Output (sgft%Ton) 144.0 Air System. CFM per System 2,600 Airflow (cfm) 7,800 Airflow (cfm/sgft) 2'.89 Airflow (cfm/Ton) 416.0 Outside Air (%) 9.4 Outside Air (cfm/sgft) 0.27 r Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible'l Latent I I CFM I Sensible 7,23 98,812 29,062 1,417 46,138 ' 0 4,941 2,307 0 0 735 26,119 -960 735 29,497 735 cfm 100.6 °F Heating Coil Supply Fan 0 0 4,9411 2,307 TOTAL SYSTEM LOAD 1 134,8671 28,1b2l 80 249 HVAC EQUIPMENT SELECTION YORK DH078N/N102AAA3A 142,642 74;607 288,000 Total Adjusted System Output 142,642 74,607 288,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Note: values above given at ARI conditions ' EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 32.0 OF 66.2 OF 100.90F 100.9 OF ' 711 Supply Air Ducts Outside Air 735 cfm 100.6 °F Heating Coil Supply Fan 7800 cfm ROOMS 69.7 OF 70.0 OF ' Return Air Ducts I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.90F 81.7 / 70.0 OF 64.6 / 63.6 OF 64.6 / 63.6 OF ' Supply Air Duct Outside Air 735 cfm Cooling Coil Supply Fan 65.2 / 63.8 OF 7800 cfm ROOMS 63.7% R.H. ' 78.6 / 69.1 OF 78.0 / 68.9 OF Return Air Ducts EnergyPro 3.1 By Ener gySoft User Number: 5021 Job Number: 02122005 Page: 26 of 31 L ' i ROOM LOAD SUMMARY , PROJECT NAME Maxce 's Grill - Home of The Charbroiler RUN#5 DATE ' 2/14/2005 SYSTEM NAME HVAC Rooftop Pkg Units'(3) FLOOR AREA 2,700 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Restaurant Restaurant 1 7,271 99,363 29,062 7,231 98,812 29,062 1,417 46,138 i " I i PAGE TOTAL 7,231 98,812 29,062 1,417 46,138 TOTAL 1 7,231 98,812 29,062 1,417 46,138 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:27 of 31 EROOM HEATING PEAK LOADS f' Project Title Date Maxce 's Grill - Home of The Charbroiler RUN#5 2/14/2005 Room Information Desi n Conditions ` Room Name Restaurant Time of Peak Jan 12 am Floor Area 2,700 Outdoor Dry Bulb Temperature 32°F ' Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 46 138 Infiltration: r 1.00 X 1.064 ' X 2 700 X 10.00 X 0.00 /601 X 38 = C� schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 46,138 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:28 of 31 2.70b.0 X X X X X X x x X X X X X x x x X X X x X X X X x X x X X x x X X X X x X X X 0.0347 X X X X x x x x X X X X X. X x X X x x' x x X x x x X x X X x x X X x X x X x X 38.0 = = = = = - = = = = = = c = = = c = = = = = = = 3,563 erimeter = 150.0 41.5 6,225 1,v1.0 0.1450 38.0 10,857 495.0 1.1900 38.0 22,384 63.0 1.2500 38.0 2.992 21.0 0.1460 38.0 116 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 46 138 Infiltration: r 1.00 X 1.064 ' X 2 700 X 10.00 X 0.00 /601 X 38 = C� schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 46,138 EnergyPro 3.1 By EnergySoft User Number: 5021 Job Number: 02122005 Page:28 of 31 } k00M COOLING PEAK LOADS Project Title Maxce 's Grill - Home of The Charbroiler RUN#5 Date 2/14/2005 ROOM INFORMATIONI DESIGN CONDITIONS 32.3 Room Name Restaurant Time of Peak Jul 2 pm Floor Area 2,700 Outdoor Dry Bulb Temperature 111 C� Indoor Dry Bulb Temperature 78OF Outdoor Wet Bulb Temperature 78 OF Conduction h-30 Roof(R.30.2x12.16) -19 Metal Stud Wall Area 4 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain indovvs-24'6"x10' Alu SP Glass Door#D1.Met SP Clear U -Value 1 0.03471 x •x x x x x X ,x x DETD 1 = = = = = = = = _ 64.7 32.3 20.3 20.2 34.8 20.3 37.8 44.7 47 Page Total Orientation Area X X x X x X X x X X SGF X X X x X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = (North) 250.0 47 0.864 0.703 _(North) 42.0 47 0.856 0.703 (East) 245.0 47 0.864 1.726 (East) 21.0 47 0.856 1.726 Page Total Btu/hr 6,064 2,212 6,048 1,593 3,802 5,927 4,082 137 29 867 Btu/hr 7.13 1,188 17,167 1,459 26 945 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 2,700 x 1.243 Watts/sgft x 3.41 Btuh/Watt x 0.998 = 11,430 ccu ants 1.0c X 2,700 X 274 Btuh/occ. / 3 sgft/OCC. X 1.00 = 23,841 Receptacle 1.0 x 2,700 x 0.790 Watts/sgft x 3.41 Btuh[Watt x 1.00 = 7,280 rocess 1.0 x 2,700 x 0.000 Watts/sgft x 3.41 BtuhfWatt x 1.00 = 0 Infiltration: chedulle x Air Sensible x Area x Ceiling Height x ACH.00 / s], X QT 34 = 0p Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 99,363 Sched. Latent Gain Frac. ccu ants 1.00 Receptacle 1.00 ' Process 1.00 Infiltration: ch I Area Heat Gain - Btu/hr x 2 700 x 334 Btuh/OCC. / 31 sgft/occ. = 29 062 x x 0000 Watts/sqft x Btuh/Watt = x 2,700 x 0.000 Watts/sgft x 3.413 Btuh/Watt = o x x ZQo x x / 6] z n.nnnnn = Air Latent Area Ceiling Height ACH nw DOOM COOLING COIL LOADS Project Title Maxce 's Grill - Home of The Charbroiler RUN#5 Date 2/14/2005 ROOM INFORMATION DESIGN CONDITIONS 32.9 Room Name Restaurant Time of Peak Jul 3 pm Floor Area 2,700 Outdoor Dry Bulb Temperature 112 cl� Indoor Dry Bulb Temperature 78`F Outdoor Wet Bulb Temperature 78 91� Conduction 12.1 R-19 Metal Stud Wall I Area i 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain Met SP U -Value 1 0.14501 x X X x X x x X x DETD 1 = = = = = = = = = 61.2 32.9 21.4 20.7 35.2 21.4 36.6 41.5 42 Page Total Orientation Area X x x X X X X X X X SGF X X X X X X X X X x SC Weighting X X x x X X X X X X Factor = = = = = = = = = = _(North) 250.0 42 0.864 0.795 (North) 42.0 42 0.856 0.795 (East) 245.0 42 0.864 1.833 (East) 21.0 42 0.856 1.833 Page Total Btu/hr 5,734 2,255 6,381 1,628 3,845 6,253 3,944 127 30 168 Btu/hr 7,211 1,201 16,294 1,384 26 090 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0 x 2,700 x 1.243 Watts/sgft x 3.41 Btuh/Watt x 0.998 = 11,433 ccu ants 1.0 x 2,700 X 274 Btuh/occ. / 3 sgft/occ. X 1.00 = 23,841 Receptacle 1.0 x 2,700 x 0.790 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 7,280 rocess �Iclhedule 1.0 x 2,700 x 0.000 Wattslsgft x 3.41 Btuh/Watt x 1.00 = 0 Infiltration: x x x x /6]x Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 98,812 ' Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 x 2 700 X 334 Btuh/OCC. / 31 sqft/occ. = 29 062 Receptacle 1.00 x x n non Watts/sqft x BtuhlWatt = ' Process ,1.00 x 2,700 x 0.000 Watts/sgft x 3.413 BtuhlWatt = 0 Infiltration: x x Area x x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH pyy r AGHTING INSPECTION CHECKLIST LTG -I ROJECT NAME INSPECTION DATE Maxcey's,Grill - Home of The Charbroiler(RUN#5) 2/14/2005 FIXTURE CODE TYPE DESCRIPTION LAMP TYPE LAMP QUANT. NUMBER OF FIXTURES WATTS PER FIXTURE FIELD NOTES 8 2 2 ft Fluorescent T8 Elec F17T8 2 4 33.0 9 3 4 ft Fluorescent T8 Elec F32T8 3 32 93.0 9a 2 4 ft Fluorescent T8 Elec F32T8 2 4 62.0 J Type DESCRIPTION MH METAL HALIDE INC INCANDESCENT INC/LV INCANDESCENT LOW VOLTAGE CFL COMPACT FLUORESCENT FL FLUORESCENT O OTHER EnergyPro 3.1 By EnergySoft User Number: 5021 ' Job Number: 02122005 Page: 31 of 31