Loading...
06-3801 (CSCS) Revision 1 Title 24EM TITLE 24 REPORT Title 24 Report for: The Dunes Retail Center - Retail 1 79-630 Highway 111 La Quinta, CA 92253 11 Project Designer: KKE Architects 525 East Colorado Boulevard • Pasadena, CA 91101 (626) 796-8230 Report Prepared By: y C+J Technical Solutions C+J Technical Solutions and Services, Inc. 1320 Valley Vista Dr. Suite 206 Diamond Bar, CA 91765 (909) 896-3631 AUG 3 1 2007 Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT. C07079 APPROVED F"OCONSFO CONSTRUCTION Date: oar BY 8/14/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.2 by EnergySoft Job Number: C07079 User Number: 5950 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 13 Form MECH-MM Mechanical Mandatory Measures 14 HVAC System Heating and Cooling Loads Summary 16 EnergyPro 4.2 by EnergySoft Job Number: C07079 User Number: 5950 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE The Dunes Retail Center - Retail 1 DOCUMENTATION AUTHOR 8/14/2007 PROJECT ADDRESS CLIMATE ZONE 15 , 79-630 Highway 111 La Quinta HOTELIMOTEL GUEST ROOM I PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # KKE Architects (626) 796-8230 California as a civil engineer, mechanical engineer, or I am a licensed architect. DOCUMENTATION AUTHOR C+J Technical Solutions and Services, Inc. TELEPHONE 909 896-3631 Checked by/Date R F-] 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Enforcement Agency USe GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. DATE OF PLANS DOCUMENTATION AUTHOR BUILDING CONDITIONED FLOOR AREA 8,109 sq.Ft. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation Is accur to and comp) e. DOCUMENTATION AUTHOR SIGNATURE J/A C+J Technical Solutions The Principal Designer hereby certifys that the proposed building d ign repent this set of construction do m is i;.M/-, consistent with the other compliance forms and worksheets, with spedtions&d d with any other calculations s mitteih this permit application. The proposed building as designed meets th energyncy requirements contained in sections 110, 1, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. ❑ F-] R 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. R F-] 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE KKE Architects LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Require orms ECH-1 MECH-2 MECH-3 MECH-5 E PRINCIPAL MECHANICAL DESIGNER - NAME S AT LIC. NO. IM'3666j-� Polar Barr Air Conditioning,InC. �� I EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Pape:3 of 20 PERFORMANCE CERTIFICATE OF -COMPLIANCE Part 2 of 3 PERF -1 PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft - Conditioned Floor Area Unconditioned Floor_Area Conditioned Footprint Area fuel TypeI Standard sqft. sqft. sqft. Proposed , Compliance ;ENERGY COMPONENT Design 8,104 Design Margin Space Heating 1.81 Left Elevation " , 1.54 0.27 Space Cooling 289.56 666 260.89 28.67 _Indoor Fans 74.33. 19.1% 94.11 -19.78 Heat Rejection 0.00 S 0.00 0.00 Pumps,& Misc. 0.00 253 0.00 0.00 Domestic Hot Water o.00 Right Elevation Total Roof 0.00 0.00 Lighting 127:55 254 1,489 127.55 0.00 Receptacle '; 65.67 65.67 ,. 0.00 Process, o.o0 0.00 TOTALS: 558.92 549.76 9.16 Percent better than Standard: 1.6% 1.6% exdi BUILDING COMPL GENERAL INFORMATION Building Orientation Number of, Stories '. Number of Systems. Number of Zones N 0 deg Conditioned Floor Area Unconditioned Floor_Area Conditioned Footprint Area fuel TypeI 8,109 sqft. sqft. sqft. 1 0 8 8,104 51 Natural Gas Left Elevation " , Orientation Gross Area Glazing Area Glazing Ratio Front Elevation N 1 1,594 sqft. 855 sqft. 53.6% Left Elevation " , E 666 sqft. 127 sqft. 19.1% Rear Elevation S 967 sqft. 253 sqft. 26.2% Right Elevation Total Roof (w) 1. 6661 3,894 8,104 sqft. sqft. sqft. 254 1,489 sqft. sqft. sqft. 38.10/, Standard Proposed Lighting Power Density 1.423 W/sqft. 1.423 w/sqft. Prescriptive Env. Heat Loss 1,358 Btu/h 1,304 Btu/h Prescriptive Env. Heat Gain 149,020 Bcuth-F 155,339 Btu/h-F Remarks: Run Initiation Time: 08/14/07 09:30:09 Run Code: 1187109009 EnergyPro 4.2 by Energysoft User Number: 5950 Job Number: C07079 Page:4 of 20 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME The Dunes. Retail Center - Retail 1 DATE 8/14/2007 ZONE INFORMATION ` System Name Zone Name Occupancy T Type Floor Inst Area LPD ft (s . (W/sQ1 RCt-`�I�AllowedLPD*s�P, Cr ies 'Area 'Tailoreds /sR oc Load`s Tenant A Zone 1 Comp Bldg Restaurant 2,256 '1.20 m %V Tenant B Zone 1 Retail Sales, Wholesale 1,960 '1.70 �b i� . " Tenant C Zone 1 Retail Sales, Wholesale 1,650 '1.70 Tenant D -North Half 'Zone 1 Com• Bldg Restaurant 1,119 `1.20 Tenant D -South Half Zone I Comp Bldg Restaurant 1,124 -1.204, '; p, w ` ,4 Y .�� Yip fi3:.tS?.}C "5Y'z' a .? ~ i W ' I . C y es 3 iei �� KM i i {, k9ke'' YIN 10-1 U11. U� H r T" NVEW11 Notes: 1: See LTG -2 2. See LTG -4-C 3. See LTG -5-C . (items marked with asterisk, see LTG -2 -C by others) (by others)1r�ti�axL3:�# EXCEPTIONAL. CONDITIONS COMPLIANCE CHECKLIST TI... 1.. ..1 .._t_ 4. See LTG -6-C aaaxra� atm € eta�ca Items above Mr Ug special documentation m , ... ,- V-' �r—,aKV 1110 nuillb sprclneu In Ims cnecKnsti. t nese nems require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "York BHP048" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "York BHP036" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "York BP090" is designated as 3 Phase or is Exempted from the NAECA 13 SEER requirement. The HVAC System "York BP120" is designated as 3 Phase; or is Exempted from the NAECA 13 SEER requirement. - - -- - - -- - - - - -- ••••, rte• •�• •••a••�o app•Vacn appncallon nave specmcany peen reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stam Run Initiation i08/14107 00:30:09 Run Code: 1187109009 EnergyPro 4.2 by EnergySoft User Number: 5950 • Job Number: C07079, Page:5 of 20 CERTIFICATE OF COMPLIANCE ENV -1-C, PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Azm. Tilt Cond: Status Joint Appendix I IV Reference Location / Comments 1 Wall . 52 0.074 R-19 -0.0 0 90 New 09-A5 Zone 2 Wall 246 0.074 R-19 R-0.0 180 90 New 09-A5 Zone 1 3 Wall 412 0.074 R-19 -0.0 270 90 New 09-A5 Zone 1 4 Roof 2.256, 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 5 Wall 109 0.074 R-19 R-0.0 0 90 New 09-A5 Zone 1 6 lWall 139 0.074 R-19 R-0.0 180 90 New 09-A5 Zone 1 7 Roof 1,960 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 8 Wall 83 0.074 R-19 R-0.0 0 90 New 09-A5 Zone 1 9 Wall 165 0.074 R-19 R-0.0 180 90 New 09-A5 Zone 1 10 Roof 1,650 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 11 Wall 4961 0.074 R-19 R-0.0 0 90 New 09-A5 Zone 1 12 Wall 2431 0.074 R-19 R-0.0 90 90 New 09-A5 Zone 1 13 Roof 1,1191 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 14 lWall 1641 0.074 R-19 R-0.0 180 90 New 09-A5 Zone 1 15 Wall 296 0.074 R-19 R-0.0 90 90 New 09-A5 Zone 1 16 Roof 1 119 0.036 R-30 R-0.0 0 0 New 02-A9 Zone 1 FI- A, R (Now, Existing, Altered, lien ❑More than or equal to 10,000 sq.tL of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default label Certificate using the default U -tactors from Standards Table 116-A and B. Certificate shall be filed in the mntr tnes nrnian nffim A,rh,,, rnecm,.af..n -A In .hn m.,-.,..,,... # T e - - Area U -Fac' - -- - -- -- SHGC2 Act. Azm. Cond.- I Stat. w a Glazing Type Location/ Comments 1 lWindow Front N 48 0.560 NFRC 0.41 NFRC 01 New SOLARBAN 60 LOW -E Zone 1 2 Window Front N 124 0.560 NFRC 0.41 NFRC 01 New SOLARBAN 60 LOW -E Zone 1 3 Window Front N 137 0.560 NFRC 0.41 NFRC 01 New SOLARBAN 60 LOW -E Zone 1 4 Window Rear S 24 0.560 NFRC 0.41 NFRC 1801 New SOLARBAN 60 LOW -E Zone 1 5 Window Ri ht W 64 0.560 NFRC 0.41 NFRC 2701 New SOLARBAN 60 LOW -E Zone 1 6 Window Right W 96 0.560 NFRC 0.41 NFRC 2701 New SOLARBAN 60 LOW -E Zone 1 7 Window Right W 94 0.560 NFRC 0.41 INFRC 2701 New SOLARBAN 60 LOW -E Zone 1 8 Window Front N 48 0.560 NFRC 0.41 INFRC 01 New SOLARBAN 60 LOW -E Zone 1 9 Window Front N 124 0.560 NFRC 0.41 INFRIC 0 New SOLARBAN 60 LOW -E Zone 1 10 Window Rear S 24 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 11 Window Rear S 76 0.560 NFRC 0.41 NFRC 180 New I SOLARBAN 60 LOW -E lZone 1 12 Window Rear S 4 0.560 NFRC 0.41 NFRC 180 New ISOLARBAN 60 LOW -E lZone 1 13 Window Front N 48 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E lZone 1 rrNa. , ro-.. utnaml rause from Standards, ladle Ni Default Iable from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 11&B Default Table from Standards, CDG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # 1 Exterior Shade Type None SHGC 0.76 Window Hgt. Wd. 8.0 3.0 Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t- 4.0 0.1 4.0 4.0 2 None 0.76 8.0 15.0 4.0 0.1 4.0 4.0 3 None 0.76 8.0 10.8 4.0 0.1 4.0 4.0 4 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 5 None 0.76 6 None 0.76 7 None 0.76 8 None 0.76 3.0 16.0 4.0 0.1 4.0 4.0 9 None 0.76 8.0 9.0 4.0 0.1 4.0 4.0 10 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 11 None 0.76 12 None 0.76 8.0 2.0 4.0 0.1 4.0 4.0 13 None 10.76 1 8.0 6.0 4.0 0.1 4.0 4.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES 1:1The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least o.5 Wlsq.ft. If this box Is checked. ENV.d-C ..Int tw ntlon nut -he.. �.,w..,nn......... ..- ------ 1-1- ..___.,_ a ..f+V...a­r. EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Page:6 of 20 CERTIFICATE OF COMPLIANCE ENV -1-C (PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 OPAQUE SURFACES MOM Ins-Ala-rion Cay. Cont. ME EMM Area U -Fac' IV Reference Act.Cond. Azrn Stat. Glazing Type Location/ Comments 14 Window Front N 100 0.560 NFRC 0.41 JNFRC 01 New SOLARBAN 60 LOW -E Zone 1 15 Window Rear S 24 0.560 NFRC 0.41 INFRIC 1801 New SOLARBAN 60 LOW -E Zone 1 16 Window Rear S 42 0.560 NFRC 0.41 NFRC 1801 New SOLARBAN 60 LOW -E Zone 1 17 Window Front N 48 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 18 Window Front N 90 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 19 Window Front N 88 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 20 lWindow Left E 90 0.560 NFRCI 0.41 NFRC 90 New SOLARBAN 60 LOW -E Zone 1 21 Window Rear S 21 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 22 Window Left E .37 0.560 NFRC 0.41 NFRC 90 New SOLARBAN 60 LOW -E Zone 1 More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default label Certificate using the default 1.1 -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's nmiect office durinn mnsmtrtinn and In the huildinn man On nxi-exp, enn<vurti..n # T e Area U -Fac' SHGC2 Act.Cond. Azrn Stat. Glazing Type Location/ Comments 14 Window Front N 100 0.560 NFRC 0.41 JNFRC 01 New SOLARBAN 60 LOW -E Zone 1 15 Window Rear S 24 0.560 NFRC 0.41 INFRIC 1801 New SOLARBAN 60 LOW -E Zone 1 16 Window Rear S 42 0.560 NFRC 0.41 NFRC 1801 New SOLARBAN 60 LOW -E Zone 1 17 Window Front N 48 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 18 Window Front N 90 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 19 Window Front N 88 0.560 NFRC 0.41 NFRC 0 New SOLARBAN 60 LOW -E Zone 1 20 lWindow Left E 90 0.560 NFRCI 0.41 NFRC 90 New SOLARBAN 60 LOW -E Zone 1 21 Window Rear S 21 0.560 NFRC 0.41 NFRC 180 New SOLARBAN 60 LOW -E Zone 1 22 Window Left E .37 0.560 NFRC 0.41 NFRC 90 New SOLARBAN 60 LOW -E Zone 1 1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, CCG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Overhang Left Fin Right Fin Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. Hot. Dist. Len. H t. 14 None 0.76 8.0 6.5 4.0 0.1 4.0 4.0 15 None 0.76 8.0 3.0 4.0 0.1 4.0 4.0 16 None 0.76 8.0 2.0 4.0 0.1 4.0 4.0 17 None 0.76 18 None 0.76 19 None 0.76 8.0 11.0 4.0 0.1 4.0 4.0 20 None 0.76 21 None 0.76 22 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD /or general lighting of at least 0.5 W/sq.ft. If this box Is checked. ENV -4-C must be flned nut whpn cuhmunn� nndp. tt.p n.p�...i..u..e r•.......n......., w- EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Paoe:7 of 20 CERTIFICATE OF COMPLIANCE MECH-I-C PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operatinq and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the lactoty and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 V of space or less and 25% or more of the ducts are in nonconditioned or semicondidoned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Stufhr. -Water-loop Heat Pump Controls Applies to all new waterfoop heat pump systems where the combined loop pumps are greater clan 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment re uirin acceptance testing EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Page:8 of 20 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM FEATURES I I tM UH 5Y51 tM IAG(5) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES ' Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor. Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance T-24 Section AIR SYSTEMS Central or Single Zone Tenant A Tenant B Tenant C 2 2 2 Reference on Pians or Specification 1 112(a) 2.20 COP 7.70 HSPF 7.70 HSPF 112(a) 10.6 EER 13.0 SEER / 11.3 EER 13.0 SEER / 11.3 EER 112(b) Yes Yes Yes 112(c), 115(a), n/a n/a n/a 121(b) No No No 121 b 1128 cfm 490 cfm 412 cfm 121 c No No No 121 c No No No 121 c 122(e) Programmable Switch Programmable Switch Pro rammable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122(f) Gravity Gravity Gravity 122 n/a n/a n/a 123 124 R-4.2 R-4.2 R-4.2 144 a & b n/a n/a n/a 144 a & b 106,177 btuh 56,212 btuh 56,212 btuh 144 a & b n/a n/a n/a 144 a & b 140,200 btuh 72,172 btuh 53,564 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c No No No 144 d No No No 144 a No Economizer No Economizer No Economizer 144 f Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 251% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Page:9 of 20 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C ]PROJECTNAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM FEATURES . AIR SYSTEMS Central or Single Zone ITEM OR SYSTEM TAG(S) .. Tenant D -North Half Tenant D -South Half Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification t Heating Equipment Efficiency y Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation . VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones, t Pipe Insulation Duct Insulation .PRESCRIPTIVE MEASURES Calculated Heating Capacity z 1.43'2- Proposed .432Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212' ` Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer, Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 112(a) 2.20 COP 2.20 COP 112(a) 10.3 EER 10.6 EER 112(b) Yes Yes 112(c), 115(a) n/a n/a 121(b) No No 121 b 763 cfm 766 cfm 121 c No No 121 c No No 121 c 122(e) Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Require 122(f) Gravity Gravity 122 n/a n/a 123 124 R-4.2 R-4.2 144 a & b n/a n/a 144 a & b 53,'089 btuh 53,089 btuh 144 a & b n/a n/a 144 a & b 87,918 btuh 68,784 btuh 144 c Constant Volume Constant Volume 144 c 144 c No No 144 d No No 144 a No Economizer No Economizer 144 If Constant Temp Constant Tem 144 (f) Constant Temp C--ronstant Temp 144 k No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "NW in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgff; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. �. EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Page: 10 of 20 MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE The Dunes Retail Center - Retail 1 1 8/14/2007 PRESCRIPTIVE REHEAT LIMITATION Section 144(d)) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM ti Nn� pa .T.. Of .: a fat) �n,T � " E °o cM �'�� xD 0 `� °' Z c m3 pQ � � m °. M•,0 tnm O � � p Cr `G mfg xp �� � ...pp. o00 �xv � O � " D n»M T• 'S Dtp p N o p\ 0M0 TN � C � v H A '�Xo It a 2Z n O 0 3 an -w r= Mf-. coo to m ap .p+ P D rn D Zone 1 2,25q 0.38 857 857 1,128 Tenant A I Total 857 1,128 Zone 1 1196 0.25 490 490 490 Tenant B Total 490 490 Zone1 1,650 0.25 412 412 412 Tenant C Total 412 412 one 1 1,119 0.38 425 425 763 Tenant D -North Half Total 425 763 one 1 1,124 0.38 427 427 766 Tenant D -South Half Total 427 766 E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REO'D V.A.1 Is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). i Must be greater than or equal to H or use Transfer Air column N to make up the difference. J Design fan supply cfm Fan CFM x 30%; or K Condition area ft. s x 04 cfm/ft. s .• or L Maximum of Columns H J, K or 300 cfm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M. Ener Pro 4.2 by Ener Soft User Number: 5950 Job Number: C07079 Page: 11 of 20 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME The Dunes Retail Center - Retail 1 Control DATE 8/14/2007 CHILLER AND TOWER MARY Type In Plenum EfficiencyTons Buried PUMPS Equipment Name Equipment T e Q�-[ Tot. GPM BHP Motor Eff. Drive Eff. Pump Control CENTRAL SYSTEM RATINGS HEATING • COOLING System Name System Type Output Aux. kW Eff. Output Efficiency Condition Status Economizer Type York BPO90 Packaged DX 3 85,000 0.0 2.20 COP 89,000 10.6 EER New BOILER York BHP048 Energy I Standby ANK INSUL. Rated Condition Factor Loss or Ext. Svstem Name Svstem TVDe Distribution Tvpe QtV Inout ,Vol.Gals.) Status or RE Pilot I R -Val. Hot Water P mp Hot Water Pipinq Len th ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING • COOLING System Name System Type Output Aux. kW Eff. Output Efficiency Condition Status Economizer Type York BPO90 Packaged DX 3 85,000 0.0 2.20 COP 89,000 10.6 EER New No Economizer York BHP048 Packaged DX 2 45,000 0.0 7.70 HSP 47,000 13.0 SEER/ 11.3 EER New No Economizer York BHP036 Packaged DX 2 45,000 0.0 7.70 HSPF 35,000 13.0 SEER/ 11.3 EER New No Economizer York BP120 Packaged DX 1 85,00 0.0 2.20 COP 120,000 10.3 EER New No Economizer ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE The Dunes Retail Center - Retail 1 1 8/14/2007 DESCRIPTION Designer Enforcement 0 1118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. 0 § 118(c) All Insulating Materials shall be Installed In compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. 0 § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. 0 § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows installed shall have air Infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. 0 §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls In nonresidential buildings shall have Insulation with an Installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number: User Job Number: C07079 Page: 13 of 20 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE The Dunes Retail Center - Retail 1 1 8/14/2007 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies RX §111 Any appliance for which there is a California standard established In the Appliance Efficiency Regulations will comply with the applicable standard. R§ 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. FV -1 § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be Installed with one of the following: § 122(e)1 A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is Interrupted; or F] § 122(e)1 B An occupancy sensor to control the operating period of the system; or ❑ § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. 0 § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(8) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with Isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X❑ § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. ❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: C07079 Page: 14 of 20 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE 'The Dunes Retail Center - Retail 1 8/14/2007 Description Designer Enforcement Ventilation [X§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. X] § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121 (f)4 Another method approved by the Commission. Service Water Heating Systems §113(b)2 if a circulating hot water system is Installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water Is not required. § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number: User Job Number: C07079 Page: 15 of 20 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM NAME FLOOR AREA Tenant A 2,256 [ENGINEERING CHECKS ISYSTEM LOAD Number of Systems 2 Heating System Output per System 85,000 Total Output (Btuh) 170,000 Output (Btuh/sqft) 75.4 Cooling System Output per System 89,000 Total Output (Btuh) 178,000 Total Output (Tons) 14.8 Total Output (Btuh/sqft) 78.9 Total Output (sgft/Ton) 152,1 Air System CFM per System 3,000 Airflow (cfm) 6,000 Airflow (cfm/sqft) 2.66 Airflow (cfm/Ton) 404.5 Outside Air (%) 18.8 Outside Air (cfm/sqft) 0.50 Note: values above given at ARI conditions :ATING SYSTEM 26.0 OF Outside Air 1128 cfm 69.8 of 111.0 / 77.6 of Out—�;1 — siae Air 1128 cfm 75.6/62.4 of 4.2 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Heating Coil COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 3,313 70,522 18,800 546 20,349 0 3,526 1,017 0 0 1,128 42,529 20,484 1,128 52,628 0 0 3,526 1,017 120,1031 39 284 75 012 BPO90 140,200 20,513 106,177 Total Adjusted System Outputiao,2oo 20,513 106,177 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Jul 4 m Jan 12 am 105.0 of Supply Air Ducts Supply Fan 104.8 of 6000 cfm ROOMS 70.0 of Return Air Ducts 82.2/65.7OF 55.0/53.7OF 55.0/53.7OF .' T_� Supply Air Ducts Cooling Coil Supply Fan 55.6 / 53.9 of 6000 cfm 49.1% R.H. ROOMS 75.0/62.2 of Return Air Ducts ' User Number: 5950 Job Number: C07079 Pane:16 of 20 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM NAME FLOOR AREA Tenant B 1,960 Number of Systems 1 2 Heating System Output per System 45,000 Total Output (Btuh) 90,000 Output (Btuh/sgft) 45.9 Cooling System Output per System 47,000 Total Output (Btuh) 94,000 Total Output (Tons) 7.8 Total Output (Btuh/sgft) 48.0 Total Output (sgftlron) 250.2 Air System CFM per System 1,600 Airtlow (cfm) 3,200 Airflow (cfm/sqft) 1.63 Airflow (cfm/ron) 408.5 Outside Air (%) 15.3 Outside Air (cfm/sqft) 0.25 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent CFM I Sensible 2,368 42,835 8,167 313 11,649 0 2,142 582 0 0 490 20,528 8,911 490 22,855 0 0 2,142 582 67,6771 17,0781 F 35,6691 York BHP048 72,172 10,442 56,212 Total Adjusted System Output 72172 1o,aa2 56,212 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug3 m Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 63.1°F 105.0°F 105.0 OF 77 Supply Air Ducts Outside Air YJ 490 cfm �104.8 OF Heating Coil Supply Fan 3200 cfm ROOMS 69.8 OF 70.0 °F 12.0 / 77.9 OF ) ---V Outside Air 490 cfm 72.6/61.4 °F ' k Return Air Ducts 4 78.7 / 64.3 OF M 55.0 / 53.9 OF Cooling Coil Supply Fan 3200 cfm 55.0 / 53.9 of Supply Air Ducts 55.6/54.1OF 54.2% R.H. ROOMS 72.0 / 61.2 OF h Return Air Ducts 11 EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Page:17 of 20 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM NAME FLOOR AREA Tenant C 1,650 Number of Systems 2 Heating System Output per System 45,000 Total Output (Btuh) 90,000 Output (Btuh/sqft) 54.5 Cooling System Output per System 35,000 Total Output (Btuh) 70,000 Total Output (Tons) 5.8 Total Output (Btuh/sgft) 42.4 Total Output (sgftlron) 282.9 Air System CFM per System 1,200 Airflow (cfm) 2,400 Airflow (cfm/sqft) 1.45 Airflow (cfmrron) 411.4 Outside Air (%) 17.2 Outside Air (cfm/sqft) 0.25 Note: values above given at ARI conditions 26.0 of 0 Outs 412 cfm 73.8 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK ICOILHTG.PEAK CFM Sensible Latent 1CFM1 Sensible 1,665 33,671 6,875 287 9,484 0 1,684 474 0 0 412 16,391 7,527 412 20,990 0 0 1,684 474 53,4401 14 402 31 423 BHP036 53,564 8,823 56,212 Total Adjusted System Output 53,564 8,823 56,212 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Jul 3pml 1 Jan 12 am 65.60F N 105.00F Heating Coil 105.0 OF Supply Air Ducts Supply Fan 104.8 of 2400 cfm ROOMS 74.0 OF Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 112.0/77.9 OF 81.1 /65.2 OF 55.0/53.8 OF 55.0/53.8 OF Supply Air Ducts Outside Air 412 cfm Cooling Coil Supply Fan 55.7 / 54.0 of 2400 cfm 50.6% R.H. ROOMS 74.7/62.10F 74.0/61.8 OF Return Air Ducts ' EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Paae:18 of 20 r 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM NAME FLOOR AREA Tenant D -North Half 1,119 26.0 OF 1� Outside Air 763 cfm 69.9 OF 12.0 / 77.9 OF Outer v side Air 763 cfm 72.4/61.5 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan .Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEA I COIL HTG. PEAK CFM I Sensiblel Latent I CFM I Sensible 2,114 38,239 12,716 321 11,963 0 1,912 598 0 0 763 32,113 13,460 763 35,612 0 0 1,912 598 74 18 26 176 F7748 771 York BP 120 87,918 18,864 53,089 Total Adjusted System Output87,918 18,864 53,089 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 prn Jan 12 am RIGS (Airstream Tei 61.50F fi5.7 105.00F Heating Coil Supply Fan 4000 cfm 105.0 OF -� Supply Air Ducts 104.9 OF ROOMS 70.0 OF h Return Air Ducts `i r%,nrsvMr-i r 11Ub (Airstream f emperatures at • 80.0/65.1OF. 55.0/53.9 OF Cooling Coil Supply Fan 4000 cfm 55.0 / 53.9 OF -4 Supply Air Ducts 55.4 / 54.0 of 54.9% R.H. ROOMS 72.0 / 61.3 OF h Return Air Ducts 'I I ' EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Paae:19 of 20 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Dunes Retail Center - Retail 1 8/14/2007 SYSTEM NAME FLOOR AREA Tenant D -South. Half 1,124 Number of Systems 1 Heating System Output per System 85,000 Total Output (Btuh) 85,000 Output (Btuh/sqft) 75.6 Cooling System Output per System 89,000 Total Output (Btuh) 89,000 Total Output (Tons) 7.4 Total Output (Btuh/sqft) 79.2 Total Output (sgft/Ton) 151.6 Air System CFM per System 3,000 Airflow (cfm) 3,000 Airflow (cfm/sqft) 2.67 Airflow (cfm/Ton) 404.5 Outside Air (%) 25.5 Outside Air (cfm/sqft) 0.68 Note: values above given at ARI conditions 26.0 OF ?� Outside Air 766 cfm 69.9 of 58.7 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK IICOILHTG. PEAK CFM Sensiblel Latent 11CFM1 Sensible 1,567 28,342 12,773 126 4,699 0 1,417 235 0 0 766 32,257 12,842 766 35,825 0 0 1,417 1 235 63,465 25 615 F77470:9915 York BP090 68,784 12,153 53,089 Total Adjusted System Output x8,784 12,153 53,os9 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug3 m Jan 12 am ,earn Temperatures at Time of Heating Peak) 105.0 of 105.0 of Heating Coil Supply Fan 3000 cfm in Return Air Ducts `S Supply Air Ducts 104.9 of ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Coolin Peak 112.0/77.9OF 82.6/66.4OF 55.0/53.8OF 55.0/53.8OF Q _ Supply Air Ducts Outside Air 766 cfm } Cooling Coil Supply Fan 55.4 / 54.0 of 3000 cfm 55.9% R.H. ROOMS 72.4/61.8 of 72.0/61.6OF Return Air Ducts I EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C07079 Page:20 of 20 1 r ' LEGACY REPORT NER-574 Reissued November 1, 2005 ICC Evaluation Service, Inc. lUmble-Regional Office ■ 5360 Worimm W Road, Whiter. Caf forma 90601 ■ (562) 6990543 www.ICC�S.Org Regional Office ■ 900 Montclair Road, Suite A, Birmingham, Alabama'35213 ■ (205) 599.9800 Regional Office ■ 4051 West Flossmoor Road, Country Club Hills, Illinois 60478 ■ (708) 799-2305 t s . Legacy report on the 2000 International Building Code®, the BOLA® National Building Code/1999, the 1999 Standard Building Code®, the 1997 Uniform Building Code'*', and the 2000 International Residential Code® DIVISION 09—FINISHES Dens -Glass Gold sheathing is manufactured to conform tothe < Section 09250—Gypsum Board applicable physical requirements of ASTM C 79 for gypsum sheathing board and has the following characteristics: ' G -P GYPSUM CORPORATION r 2861 MILLER ROAD 5/8 inch (15.9 mm) F DECATUR, GEORGIA 300364036/2 inch (12.7 mm) thick Dens -Glass WEBSITE: www.cip.com/gypsum thick Dens -Glass Gold Fireguard Gold Gypsum Type X Gypsum 1.0 SUBJECT Sheathing Sheathing Dens=Glass®Gold Sheathing: '/2 inch (12.7 mm) thick Dens- . Thickness '/2" t %2" 5/e^ t '/32" Glass® Gold Sheathing and 51, inch (15.9 mm) thick Dens - Glass® Gold Fireguard® Type X Sheathing Weight, lbs/m sq. ft., a 2.0 PROPERTY FOR WHICH EVALUATION IS SOUGHT nom. 1900 2500 2.1 Equivalent performance to ASTM C 79 (gypsum Width, nom, 4 ft. t'/8" 4 ft. t'/8" sheathing) Length, std. 8 ft.;10 ft. t'/4" 8 ft.;10 ft. t'/," 2.2 Noncombustibility Color Yellow Yellow 2.3 Fire resistance Edges Square Square 5' 2.4 Structural (racking strength) Core Water Resistant Water Resistant 3.0 DESCRIPTION Surfacing, Dens -Glass Gold sheathing is a noncombustible, resinous Face Resinous Coated Resinous Coated coated, glass fiber mat faced, water-resistantgypsum Glass Fiber Mat Glass Fiber Mat sheathing. Dens -Glass Gold is mechanically attached to Surfacing, structural. framing as a single ply backing for exterior surfacing or wall covering materials on buildings of all Back Glass Fiber Mat Glass Fiber Mat construction types. "R" Value Dens -Glass Gold sheathing is available in two varieties; ". (hr ft2.°F/Btu)' 2 inch (12.7 mm) thick Dens -Glass Gold Gypsum Sheathing (ASTM C 518) 0.56 not provided and 518 inch (15.9 mm) thick bens -Glass Gold Fireguard Type Permeance X Gypsum She CIT74� .(ASTM E 96) 23.1 Perms 12.4 Perms units: BUILsl 1 inch = 25.4 mm. 1 foot = 304.8 mm 1 hr-ftz-°F/Btu = 0.176 m2.M 1 Perm = 57 ng/(Pa-s•m2) DATE ICC -ES legacy repos are not to be construed as representing aesthetics or any'other•attributes not specifically addressed, nor are they to be construed 41 an endorsement ofthe subject of the report ora recommendation for its use. There is no warranty by ICC Evaluation Service, Inc., express or implied, as to any finding or other matter in this report, or as to any product.covered by the report. V, Copyright ° 2005 Page 1 of 3 7q -w 1070 -/zo /ll Page 2 of 3 NER-574 When tested in accordance with ASTM E 84,.the'Dens-Glass 4.3 Application to Metal Stud Curtain Walls (for Gold sheathing demonstrated a flamespread index of 25 or Transverse Wind Load Resistance) less and a smoke=developed index of 450 or less. For an allowable transverse wind load pressure of 21.7 psf When tested in accordance with ASTM E 136, the Dens- (1.04 kN/mZ), Dens -Glass Gold shall be installed with the long Glass Gold sheathing was determined to be noncombustible. dimension in the vertical or horizontal direction, mechanically ` When tested in accordance with an ASTM E 119, '/Z inch fastened to minimum 20 gauge steel framing. The stud spacing shall not exceed 16 inches (406 mm) o.c. for'/2 inch (1.2.7 mm) thick Dens -Glass Gold sheathing demonstrated thick Dens -Glass and 24. inches (609 mm) o.c. for 5/e inch that It met the code requirements for use as a 15 -minute thick Dens -Glass. Fasteners shall be 1 inch to 11/4 inch (25.4 thermal barrier for protecting foam plastics which might be to 31.8 mm) long No. 6 Type S-12 bugle -head, self -tapping, installed as a part of an exterior wall covering assembly. rust resistant screws spaced 8 inches (203 mm) o.c. along When tested in accordance with ASTM E 119, 5/6 inch (15.9 the edges and 8 inches (203 mm) o.c..at the intermediate mm) thick Dens -Glass Fireguard Type X sheathing applied to supports. Screws shall be a minimum edge distance of 3/e a partition in a single -layer nail application on each face of inches (9.5 mm). load-bearing wood framing members provided a one hour fire s resistance, thus qualifying it for the "Type X' designation of 5.0 IDENTIFICATION ASTM C 79. j 4.0 INSTALLATION Each bundle or package of Dens -Glass Gold sheathing shall bear the manufacturer's name and/or trademark, the NES 4.1 General - Application to Wood Stud Walls and logo. and evaluation report number, NER-574 for field identification. is Metal Stud Curtain Walls 6.0 EVIDENCE SUBMITTED Installation of Dens -Glass Gold sheathing shall be in accordance with ASTM C 1280, Application of Gypsum 6.1 Manufacturer's descriptive literature and installation Sheathing, the manufacturer's installation instructions, and instructions. this report. Exterior surfacings or wall coverings shall be provided over the Dens -Glass Gold sheathing as weather 6.2 Report of physical and racking load tests conducted protection. Weather -resistant membranes .(No.15 asphalt- on '/y inch (12.7 mm) thick Dens -Glass Gold saturated felt or other approved material) shall be provided sheathing, prepared byTimberProducts Inspection, over the Dens -Glass Gold sheathing before attaching such Project No. 85-03, Report No. 1, dated February 4, surfacings or wall coverings, when required bythe.applicable 1985, signed by Walter W. Boyles. building code. Such coverings or surfacings are beyond the scope of this report. 6.3 Report on various physical tests conducted on'/2 .The installation instructions within this report will govern, if inch (12.7 mm) thick Dens -Glass Gold sheathing, prepared by Timber Products Inspection, Project there are any conflicts with the manufacturer's instructions. No. 89-018, Report No. 1, dated June 21, 1989, The manufacturer's published installation instructions and this signed by Walter W. Boyles and Franklin Holmes. report shall be strictly adhered to and a copy of these instructions shall be available at all times on the jobsite during 6.4 Test report in accordance with ASTM C . 79, installation: prepared by Timber Products Inspection, Project 4.2 Application to Wood Stud Walls (for Racking No. 86-08, Report No. 1, dated August 22, 1986, signed by Walter W. Boyles. Resistance) For resisting wind and seismic loads, the V, inch (12.7 mm) 6.5 Test report in accordance with ASTM C 79, prepared by Timber Products Inspection, Project thick Dens -Glass Gold sheathing is assigned an allowable No. 89-018, Report No. 2, dated June 21, 1989, racking value of 99 plf (1.44 kN/m) when applied to wood stud signed by Walter W. Boyles. walls as noted in the following paragraph. The. maximum height -length ratio shall not exceed 1.5:1 to be considered as 6.6 Test report in accordance with ASTM E 84, a shear wall segment. Marginal. studs and plates shall be anchored to resist design forces. Shear walls using Dens- prepared by Commercial Testing Company, Report Glass Gold sheathing shall not be used to resist forces No. 32983, dated February 6, 1985, signed by Jonathan Jackson. imposed by masonry and concrete walls. See Section 7.5 of this report for allowable load adjustments or restrictions 6.7 Test report in accordance with ASTM E 84, applicable to certain seismic regions. prepared by Commercial Testing Company, Report The Dens -Glass Gold sheathing shall be applied solidly to the No. 67324, Test No. 2024-7678, dated May 5,1989, wall with the long dimension in the vertical direction with all signed by Jonathan Jackson. edges backed by framing members. Application shall be by the use of nails: 11 gauge, /18 inch (11.1 mm) head, "/Z inch 6.8 Test report in _ accordance with ASTM E 136, long (38.1 mm) for /inch. (12.7 mm) thickness; and 1% inch prepared by Commercial Testing Company, Report (44.5 mm) long for /B inch (15.9 mm) thickness, spaced 4 No. 67576, Test No. 2075-9961, dated October 18, inches (101 mm) o.c. on the edges and 8 inches (203 mm) 1989, signed by Jonathan Jackson. o.c. at the intermediate supports. Nails shall have a minimum edge distance of /e inch (9.5 mm). The stud spacing shall not 6.9 Test report in accordance with ASTM E 119, . exceed 16 inches (406 mm) o.c. for V, inch (12.7 mm) thick prepared by Commercial Testing Company, Report Dens -Glass Gold sheathing and 24 inches (609 mm) o.c. for No. 32984, dated February 6, 1985, signed by % inch (15.9 mm) thick Dens -Glass Gold Fireguard Type X Grady Gilbert, P.E. sheathing. Page 3'of 3 6.10 Test report in accordance with ASTM E 119, prepared by Wamock Hersey Intemational Inc:, File No. WHI-495-0702 and WHI-495-0703, Job No. 495-0589, dated August 711985, signed by George E. Meyer, P.E. 6.11 Test report in accordance with ASTM C 518, prepared by Commercial Testing Company, Report No. 32982, dated February 7, 1985; signed by Jonathan Jackson. 6.12 Report of wet racking tests conducted on '/2 inch (12.7 mm) thick Dens -Glass Gold sheathing in accordance with ASTM E. 72, prepared by Timber Products Inspection, Project No. 85-03, Report No. 3; dated June 24, 1985, signed by Walter W.. Boyles. 6.13 Report of racking tests conducted on conditioned samples (95 •F and 50% RH) of/2 inch (12.7 mm) thick Dens -Glass Gold sheathing. in accordance in accordance with ASTM E 72, prepared by Timber Products Inspection, Project No. -89-034, ReportNo. 1, dated September 22, 1989, signed by Walter W. Boyles. NER-574 submitted to the building official documenting that the Dens -Glass® Gold sheathing and its fastening methods are adequate under wind loads of the applicable building code. Exception: When installed to steel framing as noted in Section 4.3 of this report, Dens - Glass Gold is permitted in applications where design wind pressures do not exceed 21.7 psf (1.04 kN/m2). 7.5 Exterior stud walls shall be braced as required by the applicable code. 6.14 Report of tests conducted in accordance with ASTM E 96, prepared by Timber Products Inspection: 7.6 • Report No. 93-017, dated October 25,1993, signed by Steve Standell and Diane Michael. Report_ No. 94-017, dated July 14, 1994, signed by. Steve Standell. 6.15 Report on testing conducted in accordance with ASTM E 330, prepared by Timber Products 7.7 Inspection, Project No. 89-047, dated January 12, 1990, signed by Walter W. Boyles. 1.0 CONDITIONS OF USE The ICC -ES Subcommittee for the National Evaluation Service, Inc. finds that Dens -Glass Gold sheathing is an acceptable alternative material, product or method of construction to those specified in the 2000 International Building Code®, the BOCA® National Building Code/1999, the 1999 Standard Building Code®, the.1997 Uniform Building Coder"', and the 2000 International Residential Code®subject . 'to the following conditions: 7.1 The installation instructions given in this report and those published by G -P Gypsum shall be strictly adhered to. 7.2 The Dens -Glass Gold sheathing shall be protected from weather by an exterior surfacing or covering material approved by the local.building official. No exterior surfacing or covering listing is granted or implied by this report. 7.3' Dens -Glass Gold sheathing shall not be used as a nailing base and any mechanical attachments of. exterior coverings shall be made directly to the studs. 7.4 Exterior surfacings may be adhered to Dens -Glass Gold sheathing when approved by the local building . official. When the Dens -Glass Gold is not covered by wall covering mechanically attached directly to the studs, structural calculations, signed and sealed by a registered design professional, shall be Exception: In seismic regions where the applicable building code permits the use of shear. walls constructed using gypsum sheathing, wood stud walls employing '/2 inch (12.7 mm) thick Dens -Glass Gold sheathing are permitted to be designed as engineered shear walls in accordance with the provisions of this report. Any reductions in the allowable loads for gypsum sheathing employed in certain seismic regions which are noted in the applicable building code shall be applied to the allowable load noted in this report. Dens -Glass Gold sheathing shall be kept dry prior to installation; stored off the ground and under protective covering. Should the boards become wet, they shall be allowed. to dry prior to installation. Once installed, the Dens -Glass Gold sheathing shall be covered with an exterior surfacing or covering. This report is subject to periodic re=examination. For information on the current status of this report, contact the ICC -ES.