05-0409 (RC) Title 24TITLE 24 REPORT Title 24 Report for: Nail Salon T.I., La Quinta Valley Plaza 79-410 Highway 111,rSui#e 1�09�(Building-6)� La Quinta, Ca 92253 Project Designer: Robert Pitchford, Architect 74-835 Fox Hills Palm Desert, Ca 92260 (760) 346-8775 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION ETS DAT ACBY TX7P - Date: 2/8/05 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form LTG -4 Tailored LPD Summary and Worksheet Form LTG -5 Room Cavity Ratio Worksheet Form LTG -MM Lighting Mandatory Measures MECH 3 Mechanical Ventilation 1 2 3 8 9 10 11 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME Nail Salon T.I., La Quinta Valley Plaza This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE 2/8/05 PROJECT ADDRESS 79-410 Highway 111, Suite 109 (Building 6) La Quinta STGNATf Building Permit PRINCIPAL 6ESIGNER - ENVECUPE Robert Pitchford, Architect TELEPHONE (760) 346-8775 # DOCUMENTATION AUTHOR H & H Air Conditioning TELEPHONE (760) 340-3088 Checked by/Date Enforcement Agency Use STATEMENT OF COMPLIAWE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildi using th performance compliance approach. DOCONIENTATfOTI-AUTROK STGNATf DAT 1,353 Sq.Ft. 15 BUILDING TYPE U NONRESIDENTIAL The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION U NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ EXISTING + ADDITION STATEMENT OF COMPLIAWE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildi using th performance compliance approach. DOCONIENTATfOTI-AUTROK STGNATf DAT Tim Scott 124,010� The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. R ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. REi o 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section I-1 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. R F-1 ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) Indicate location on plans of Note Block for Mandatory Measures Envelope Compliance Not In The Scope 0 - Required Forms ThfS $Ubmittal PRINCIPAL ENVEEOPE-DESIGNER - NAM SIGNATURE -IC-ATO. DAT ILIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Re I F s TG -1 P IPA L LIGHTING DgkIGNER -NAMESI E LIC. NO. DATE SEPT TCI-f� 7 o(ME ;S -7 -OT Indicate location on plans of Note Block for Mandatory Measures Mechanical Compliance Not In the Scope Required Forms THIS SU mitts - PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE IEnergyPro 3A By EnergySoft User Number: 5533 Job Number: Page:3 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part2 of 3 PERF -1 Nail Salon T.I., La Quinta Valley Plaza --7 TE 2/8/05 ANNUAL SO= ENERGY U -5E SUMMARY u sq -yr ENERGY COMPONENT Standard Design Proposed Design Compliance Margin aiand5�d _ _ M.. Proposed Space Heating Space Cooling Indoor Fans 'Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: 0.89 1.33 -0.44 2=11 "d00fF 86.03 75.17 10.86`° 32.82 29.49 3.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 �0 50.11 19.96 30.16 15.96 15.96 0.00 0.00 0.00 0.00 185.81 141.91 43.90 0 10- . 20 . 30 40 =-= 50 60 .. 70 W kandsgft-yr GENERAL IWORMATION Building Orientation Number of Stories Number of Systems Number of Zones (East) 90 deg Conditioned Floor Area 1,353 sqft. 1 Unconditioned Floor Area 0 sqft. 2 Conditioned Footprint Area 1,353 sqft. 1 Orientation Front Elevation (East) Left Elevation (south) Rear Elevation (West) Right Elevation (North) Total Roof Gross Area sqft. sqft. sqft. sqft. sqft. sgft.sgft. Glazing Area Glazing sqft. sqft. sqft. sqft. sqft. Ratio 240 135 56.2% 360 141 39.2% 240 0 0.0% 360 01 0.0% 1,200 276 23.0% 1,353 0.0% Standard Proposed Lighting Power Density 1.700 W/sqft. 0.678 W/sgft. Prescriptive Env. Heat Loss 288 305 Prescriptive Env. Heat Gain 36,272 37,694 Remarks: Run InitiationTime: un Code: 1107881297 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: PageA of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Nail Salon T.I., La Quinta Valley Plaza DATE 2/8/05 System Name Zone Name Occupancy Type Floor Area (sgft.) Inst.Port. LPD (W/sf)1 LPD (W/sf)1 Ctrl. Credits (W/sf)2 lailorecil Proc. Loads (Wlsf) LFU (W/sf)3 HVAC 1 Building 6 Comp Bldg Retail/Wholesale 1,353 0.037 0.642 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG4 items above require special documentation P flea Gn —ramnn ---- .---. _... _. __..._... .. W t, Y r—a, naacn uvn w u"CRCnIA SPCGIIICO Irl inl5 CneCKIISt. justification and documentation, and special verification to be used with the performance approach }ha nrla--, of fhn inc--A ....... _ —:1-- __ — .. . I nese Items require special wrl en The local enforcement agency determines on t ne exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Run Initiation Time: un Code: EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 11 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 PROJECT NAME DATE Nail Salon T.I., La Quinta Valley Plaza 2/8/05 LAMPS BALLASTS Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Lamp DESCRIPTION # t�drnp # T oauas Watts Total Watts (1) 18w Compact Fluorescent Quad 2 Pin CFQ18W/G24d-2 1 18 Magnetic Standard 1.0 2 25.0 50 50 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 50 868 Efficacy and Control Requirement of §130(c) Portable Lighting (From LTG -1) Less Control Credit Watts (From LTG -3) Control Requirements of§131(f) Adjusted Actual Watts 918 CONTROL LOCATION I CONTROL CONTROL TYPE (Room # or Dwg. #) IDENTIFICATION (Occupant, Daylight, Dimming, etc.) I LUMINAIRES CONTROLLED I NOTE TO FIELD NOTE TO FIELD rvv I ca I v rrtt-u - ror munaing ueparimeni use umy Run InitiationTime: un Code: 1107881297 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 11 _IGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 Nail Salon T.I., La Quinta Valley Plaza 1 2/8/05 1 OR ZONE ID (W/sqft) (SF) (B X C) TOTAL 0 0 F ROOM # OR ZONE ID a PORTABLE LIGHTING Description # OF FIXT. a LUMIN. WATTS PER FIXTURE o TASK AREA (SF) a a a # OF TOTAL TOTAL TASK AREA (SF) WATTS AREAS (D x E) (C x E) Building 6 (4) 4 ft Fluorescent T8 Elec 7 124.0 1,353 1 1,353 868 ROOM # TOTAL AREA OR ZONE ID (SF) TOTALI 0 TOTALS 1,353 1 868 Designer needs to provide detailed documentation that the ligl level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. BUILDING SUMMARY (FROM TABLES 1A+1R+1C) (FROM TABLES 1A+1 B) BUILDING TOTAL 1,353 868 Run Initiation Time: un Code: 1107881297 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Pagel of 11 TAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 Nail Salon T.I., La Quinta Valley Plaza 2/8/05 uminance Categories , an anCl Gross Sales Area FA] 1. Watts for Illuminance Categories A -D (from column G) 01 watts 2. Watts for Illuminance Categories E -I (from LTG4 Part 2) 30 0 watts 3. Watts for Display Lighting (from LTG4 Parts 2 & 3) a 0+ 0+ 1 0= 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display ILLUMINANC CATEGORY 4. Total Allowed Watts (lines 1+2+3) > watts ALLOWED LPD ALLOWED WATTS (E x F) uminance Categories , an anCl Gross Sales Area FA] © © o a o a ROOM NAME TASK/ACTIVITY ILLUMINANC CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) tsuilding b A 1.71 0 0.20 0 PAGE TOTAL > 1 D BUILDING TOTAL 1, 3 53 SF WATTS EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 11 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -5 Nail Salon T.I., La Quinta Valley Plaza 1 2/8/05 Room Name Task/Activity Description Room Length (L) Room Width (W) Room Cavity Height (H) Room Cay. Ratio 5xHx(L+W) /(LxW) Room Name Task/Activity Description Room Area (A) Room Perimeter (P) Room Cavity Height (H) Room Cay. Ratio 2.5 x H x P /A LIGHTING MANDATORY MEASURES LTG - Nail Salon T.I., La Quinta Valley Plaza 2/8/05 DESCRIPTION Designer Enforcement �( § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. u § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. [X § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. 1XIu § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. 1XIu § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. [XI § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. u § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. U§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. [X.J § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:10 of 11 MECHANICAL VENTILATION MECH-3 Nail Salon T.I., La Quinta Valley Plaza 2/8/05 o © a o 0 o a o o a a ZONE/SYSTEM Building 6 HVAC 1 AREA BASIS AREA CFM CFM (SF) PER SF (B x C) 1,353 0.23 311 OCCUPANCY BASIS OF PER CFM PEOPLE PERSON (ExF) Trial REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS. FER AIR 311 338 311 338 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 15 1