Loading...
05-0409 (RC)RIVERSIDE COUNTY FIRE DEPARTMENT YIndio, Fax V60) 863-7072 Craig E. Anthony May 23, 2005 Fire Chief Proudly ming the Robert Pitchford Architect unincorporated 74-835 Fox Hils CL areas of Riverside Palm Desert, CA 92260 County and the Cities of Re: Non -Structural Building 'TA Plan Review LAQ-05-TI-045 /j79=410f1 WYA 111 Banning Ste1031'06107,108 11_O,111 Beaumont Fire Department personnel have reviewed and approved the plans you submitted for the above %% referenced project. Please be advised the following conditions a Calimesa P 1 g apply as a part of the conditions for the %o. issuance of a building permit Canyon Lake ,. 1) . As may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire Coachella sprinkler system plans for the tenant improvement area may be required to be submitted to the Fire N Department for review, along with a planliinspection fee. The approved plans, with Fire Department Desert Hot Springs . Job card must beat the job site for all inspections. c• Indian Wells 2) Provide keys to the tenant space for inclusion in the main building Y( Knox Box. Ke s .C.) shall have a Indio durable and legible tag affixed for identification of the correlating tenant space. Lake Elsinore 3) Install portable fire extinguishers per Title 19, but not less than 2A10BC in rating. Contact certified c• extinguisher company for proper placement of equipment La Quinta c 4) . Approved building address shall be placed in such a position as to be plainly visible and legible from Moreno Valley the street and rear access if applicable. In multi -tenant buildings, businesses shall post the `% business name and suite number on back doors.as well as the front. Suite numbers or letters must Palm Desert be a minimum of 6° in height All addressing must be legible and of a contrasting color with the �• Perris background. Rancho Mirage Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. San Jacinto Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling %% (760) 863-8886. Temecula All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Board of Supervisors Bob Buster, Sincerely, District 1 FRANK KAWASAKI JohnTavagri�osect2 Chief Fire Department Planner Jeff Stone, District 3 Roy Wilson, By District4 Walter Brandes Marion Ashley, Cc: City of La Quinta —Building Dept Fire Safety Specialist Distri 5 omua ar r weaecrsttu�oos nas.ax i EZWP EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2^a FL, Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 \: � tt- TITLE 24 REPORT Title 24 Report for: Suite 111 T.I., La Quinta Valley Plaza '79-410 Highway 111 (Building 6) La Quinta, Ca 92253 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTI9N 5 BY Project Designer: Robert Pitchford, Architect 74-835 Fox Hills Palm Desert, Ca 92260 (760) 346-8775 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 Job Number: Date: 4/15/05 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form LTG -4 Tailored LPD Summary and Worksheet 8 Form LTG -5 Room Cavity Ratio Worksheet 9 Form LTG -MM Lighting Mandatory Measures 10 MECH 3 Mechanical Ventilation 11 EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME Suite 111 T.I., La Quinta Valley Plaza This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE 4/15/05 PROJECT ADDRESS 79-410 Highway 111 (Building 6) La Quinta The Principal Designers hereby certify that the proposed building design represented in the construction documents and odelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this Building Permit # _ -- PRINCIPAL DESIGNER =ENVELOPE TELEPHONE Robert Pitchford, Architect (760) 346-8775 DOCUMENTATION AUTHOR H & H Air Conditioning TELEPHONE (760) 340-3088 Checked by/Date Enforcement Agency Use I Kun Initiation Time: 04/15105 10:38:41 Run Code: 1113586721 `EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 11 )f This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildinusing thl performance compliance approach. DOCUMENTATION AUTHOR 5 . NATURe- D T / Tim Scott I`�/ The Principal Designers hereby certify that the proposed building design represented in the construction documents and odelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this 2,684 Sq.Ft. 24, Part 6. 15 BUILDING TYPE NONRESIDENTIAL sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, HIGH RISE RESIDENTIAL [:] HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION F-] ADDITION 0 ALTERATION ❑ EXISTING + ADDITION I Kun Initiation Time: 04/15105 10:38:41 Run Code: 1113586721 `EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 11 )f This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildinusing thl performance compliance approach. DOCUMENTATION AUTHOR 5 . NATURe- D T / Tim Scott I`�/ The Principal Designers hereby certify that the proposed building design represented in the construction documents and odelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. F' ti u 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. r ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. U 3.1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) Indicate location on plans of Note Block for Mandatory Measures Envelope Compliance Not In The Scope Of Required Forms Th -i— Submittal PRINCIPAL ENVEL"OPE"DESIGNER=NAME SIGNATURE LICTNO7---7DATE ILIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Re Forms TG -1 jNJINCIPAL LIG 7y=N ;qFZIGNERI��E � it SI LIC. NO. DATE - � Cr12`SI$ b t 1 CJ5" Indicate location on plans of Note Block for Mandatory Measures Mechanical Compliance Not In the Scope Required Forms This Submittal PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE I Kun Initiation Time: 04/15105 10:38:41 Run Code: 1113586721 `EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 11 )f PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 Suite 111 T.I., La Quinta Valley Plaza ATE 4/15/05 ANNUAL SOURCE ENER6Y USE SUMMARY u sq -yr ENERGY COMPONENT Standard Design Proposed Design Compliance Margin [-staod5-rd_ 'or-'- Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: 0.34 0.78 -0.45^!^x- 0 - 10 - - 20 30 40 50 kBfiAgft-yr 37.22 28.06 9.17"CeOev° a;�E3fWE 14.42 10.84 3.58F;;. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 °^ ` 50.07 15.65 34.43 15.87 15.87 0.00 `yep 0.00 0.00 0.00 117.92 71.20 46.72 GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (East) 90 deg Conditioned Floor Area 2,684 sgft. 1 Unconditioned Floor Area 0 sgft. 2 Conditioned Footprint Area 0 sqn. 1 Orientation Front Elevation (East) Left Elevation (South) Rear Elevation (west) Right Elevation (North) Total Roof Gross Area sqn. sgft. sgft. sqft. sgft. sgft. Glazing Area Glazing sgft. sqn. sqn. sgft. sgft. sgft. Ratio 0 0 0.0% 0 o 0.0% 0 0 0.0% 0I 0 0.0% 01 o 01 E:::::� 0.0% Standard Proposed Lighting Power Density 1.700 w/sgft. 0.531 w/sgft. Prescriptive Env. Heat Loss 0 0 Prescriptive Env. Heat Gain o 0 emar s: Run InitiationTime: un Code: 1113586721 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Suite 111 T.I., La Quinta Valley Plaza DATE 4/15/05 System Name Zone Name Floor Inst. Port. Area LPD LPD Occupancy Type (sgft.) (W/sf)1 (W/sf)1 Ctrl. Credits (W/sf)2 lailoreci Proc. Loads (W/sf) (W/sf)3 HVAC 1 Suite 111 Comp Bldg Retail/Wholesale 2,684 0.023 0.508 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG4 Items above require special documentation The local entorcement agency should pay special attention o the items specified in this checklist. ese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Kun Initiation Time: 04/15/05 10:38:41 Run Code: 111358672 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 11 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 Suite 111 T.I., La'Quinta Valley Plaza (V^ 4/15/05 LAMPS I RAI I ACTC Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp DESCRIPTION # (Lamp + Ballas Total Watts # Watts (2) 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 1 62.0 62 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 62 Meets Total 62 1,364 Efficacy and Control Requirement ofg130(c) Portable Lighting (From LTG -1) Control Requirements of §131(f) Less Control Credit Watts (From LTG -3) Adjusted Actual Watts 1,426 NOTE TO FIELD LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 Suite 111 T.I., La Quinta Valley Plaza 4/15/05 1 I AtSLF- 1 b - PUK I At3l-h LIUH I IN(i SHUVVN UN PLANS t -UH UFFI(;t AREAS >25U 5QUAKE t-th 1 ---1 FA] a LUCM❑IN. TA❑SSK #❑E OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID n .... imi— FIYT FIYTI IAC /CCI ADCAC — — Suite 111 (4) 4 ft Fluorescent T8 Elec 11 124.0 2,684 1 2,684 1,364 TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 2,684 1,364 TOTAL 2,684 1,364 ROOM # OR ZONE ID TOTAL AREA (SF) Designer needs to provide detailed documentation that the lighting level provided by the overhead lighting meets the needs'of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 0 BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 2,684 1,364 KUn Initiation lime: U4/15/U5 1U:38:41 Run Code: 11135$21 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Paae:7 of 11 �AILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 PROJECT NAME DATE Suite 111 T.I., La Quinta Valley Plaza 4/15/05 - Illuminance Categories , ancl u ana Gross Sales Area o © a 1. Watts for Illuminance Categories A -D (from column G) 0 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) 0 1 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) 0 + 1 01+ = 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) 0 watts ALLOWED WATTS (E x F) Suite 111 - Illuminance Categories , ancl u ana Gross Sales Area o © a a o n ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) Suite 111 A 1.08 0 0.20 0 PAGE TOTAL 01 BUILDING TOTAL > 2,684 0 SF WATTS EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 11 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -5 Suite 111 T.I., La Quinta Valley Plaza 4/15/05 0 ® © M © M Room Name Task/Activity Description Room Length (L) Room Width (W) Room Cavity Height (H) Room Uay. Ratio 5xHx(L+W) /(LxW) a © © o o a Room Name Task/Activity Description Room Area (A) Room Perimeter (P) Room Cavity Height (H) Room Cay. Ratio 2.5 x H x P /A ji EnergyPro 3.1 By Energysoft User Number: 5533 Job Number: Pagel of 11 LIGHTING MANDATORY MEASURES LTG -MM I Suite 111 T.I., La Quinta Valley Plaza 7- 4/15/05 1 DESCRIPTION Designer Enforcement j� § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. �J § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. LJ § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. u § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. L"J § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. u § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. U§ 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 11 MECHANICAL VENTILATION MECH-3 Suite 111 T.I., La Quinta Valley Plaza 4/15/05 a a a o a o© a o a o AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS FER AIR ZONE/SYSTEM UND AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON M11. CFM (ExF) Suite 111 2,684 0.23 617 617 268 349 HVAC 1 Total 617 268 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 15