Loading...
0301-397 (CSCS) Revision 1 Title 24TITLE 24 REPORT Title 24 Report. for: THE CENTER AT LA QUINTA 79-405 Hwy. 111 La Quinta„ CA 92260. w..,..:. Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION 2t5E>l l7 Ga E S VE 3 BY STAMCO DEVELOPEMENT CO. -7q-9j r5" 4w 1L 78=060 Calle Estado, Ste 5 �� La Quinta„ CA 92260 v� 760) opo I - ��7 Report Prepared By: R.Krown CEA N98-99-620 Desert Energy Services P.O. Box 621 Rancho Mirage, CA 92270-0621 (760) 770-0044 C®rtifl®d Ener gY 'N aIYGt Fiict�{ i�f^nF.(Krown 6.—..._.�.,...,.,.,—„—,�,.,.,. Job Number: _-----_.._ Ne c� cD . 323 ' Cz-lR �R-tea Date: 5/21/20037This cooThe EnergyPro computer program has been used to perform the calculations summarized in this compliance ra has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number. 323 User Number. 2366 P TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -3 Proposed Construction. Assembly Form ENV -MM Envelope Mandatory Measures Form LTG -MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary 1 2 3 16 17 18. 19 21 EnergyPro 3.1 By EnergySoft Job Number. 323 User Number. 2366 PERFORMANCE CERTIFICATE OF COMPLIANCE NAME THE CENTER AT LA QUINTA MUM 79-405 Hwy. 111 La Quinta, _ DESIGNER - ENVELOPE STAMCO DEVELOPEMENT CO. ITATION AUTHOR Desert Energy Services _ Part 1 of 3 PERF -1 DATE 5/21/2003 TELEPHONE 760) TELEPHONE. (760) 770-0044 Building Permit # Checked by/Date Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildin sing the erformance compliance approach. DOCUMENTATION AUTHOR SIGNATOR DATE R.Krown CEA N98-99-620 Zi �The DATE OF PLANS 5/20/03 BUILDING CONDITIONED FLOOR AREA 19,857 sq.Ft CLIMATE ZONE 1 15 BUILDING TYPE NONRESIDENTIAL sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, HIGH RISE RESIDENTIAL HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION [XJ NEW CONSTRUCTION In ADDITION E:] ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildin sing the erformance compliance approach. DOCUMENTATION AUTHOR SIGNATOR DATE R.Krown CEA N98-99-620 Zi �The Principal Designers hereby certify that the proposed building esented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. . ENV. LTG. MECH. F-1. I-1 n 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. �I --I n 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. Cl n n 3.1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because.it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae'printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Requirep Forms_ PRINCIPAL PRINCIPAL ENVELOPE DESIGNER - NAME T GN URE ^ LIC. NO. DATE STAMCO DEVELOPEMENT CO. Jul. LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandato Measures Required Forms LTG -1 PRINCIPAL LIGHTING DESIGNER - NAME SIGNAT RE LIC. NO. DATE STAMCO DEVELOPMENT CO. MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandato ea es MECH-1,_MECH-2, MECH-3 _ Requir Fyorms PRINCIPAL MECHANICAL DESIGNER - NAME I S A ILIC. NO. —_t _{LAR BARIR R ACONDITIONING _ P✓1�,5. j'��zzy I AT S U3 i jEnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Page:3 of 25 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF- TME ERF- TME �ENTET ATLA Q!11 R DATE 5/21 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance ENERGY COMPONENT Design Design _Margin p Standard M Pmposed .Space Heating 1.06 1.37 -0.31 Space Cooling 59.31 67.03 -7.72 Indoor Fans 34.52 33.54 0.98 Heat Rejection 0.00 0.00 0.00 , Pumps & Misc. 0.00 0.00 0.00,, Domestic Hot Water 21.47 20.86 0.60 Lighting 58.89 46.67 12.22 Mi6p •' Receptacle 16.94 16.94 3,5 0.00` Process 0.00 0.00 0.00 0 10 20 00 40 50 80 TOTALS: 192.19 186.41 5,78 kBtu/W-yr Percent better than Standard: 3.0% ( 3.0%° excluding process)( 3.3% excluding process & receptacle) BUILDING COMPLIES GENERAL INFORMATION Building Orientation North 0 deg Conditioned Floor Area 19,857 sqft. 1 Number of Stories Unconditioned Floor Area 0 sqft. 13 Number of Systems Conditioned Footprint Area 19,839 sqft. 5 Number of Zones Orientation Gross Area Glazing Area Glazin Ratio 2,796 1,988 71.1% Front Elevation (North) sqft. sqft. 960 0 0.0% Left Elevation (East) sqft. sqft. 2,796 0 0.0% Rear Elevation (South) sqft. sqft. 984 690 70.1% Right Elevation Total Roof (West) sgft. sqft. sqft. 1sqft. sqft. sqft. 7,536 2,678 19,839 0.0% Standard Proposed Lighting Power Density 2.000 W/sgft. 1.585 W/sgft. Prescriptive Env. Heat Loss .2,835 2,998 Prescriptive Env. Heat Gain 332,802 352,642 Remarks: Standard Building (Compliance) Run Initiation Time: 05/21/0310:00:34 Run Code: 1053536434 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number. 323 Page:4 of 25 nCncnnw■ w lklo% - _ kor-K I WICATE OF COMPLIANCE Part 3 of 3 PERF 7-1] f PROJECT NAME THE CENTER AT LA OUINTA DATE - _ 5/21/2003 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft.) Inst. LPD (W/sf)1 Port. LPD (W/sf)1 Ctrl. Credits (Wls 2 Tailored Proc. Loads (W/sf) LPD (Wlsf) 3 PACKAGE # 12 A. B RETAIL Retail/Wholesale Sales 3,840 1.620 0.200 PACKAGE 5;6,7,8,9 RETAIL Retail/Wholesale Sales 9,600 1.344 0.200 PACKAGE # 1, 2, 3 RETAIL Retail/Wholesale Soles 2,416 1.291 0.200 PACKAGE 4 RETAIL Retail/Wholesale Sales 801 1.473 0.000 PACKAGE 10 & 11 RETAIL Retail/Wholesale Sales 3,200 1.525 0.000 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special 'use tification and documentation submitted. I o�,.. I r.e�a The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Page:5 of 25 1 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME THF_ CENTER AT LA OUINTA DATE 5/21/2003 OPAQUE SURFACES Area U -Fac. Act. Azm. SHGC Glazing Type Location I Comments 1 Window 42 0.870 0 Surface Framing # Type Type Act. Area U -Fac- Azm. Tilt Solar Gains y/N Form 3 Reference Location / Comments 1 Roof Wood 3,840 0.034 0 0 X I 113/U Roof R.30 Truss T -Bar RETAIL 2 Wall Wood 188 0.065 0 90 0.60 R-19 Wall W.19.2x6.16 RETAIL 3 Wall Wood 939 0.065 90 90 X R-19 Wall (W.19.2x6.16) RETAIL 4 Door None 21 0.581 90 90 7 Window Hollow Metal Door RETAIL 5 Wall Wood 555 0.065 180 90 0 R-19 Wall W.19.2x6.16) RETAIL 6 Door None 21 0.581 180 90 X Hollow Metal Door RETAIL 7 Roof Wood 1,920 0.034 0 0 X1 B/U Roof R.30 Truss T -Bar RETAIL 8 Wall Wood 90 0.065 0 90 X R-19 Wall W.19.2x6.16 RETAIL 9 lWall Wood 231 0.065 180 90 X JR-19Wall W.19.2x6.16 RETAIL 10 Door None 21 0.581 180 90 X Hollow Metal Door RETAIL 11 Roof Wood 1,920 0.034 0 0 X B/URoof (R.30 Truss) T -Bar RETAIL 12 Wall Wood 87 0.065 0 90 X R-19 Wall (W.19.2x6.16) RETAIL 13 Wall Wood 231 0.065 180 90 X JR-19Wall W.19.2x6.16 RETAIL 14 Door None 21 1 0.581 180 90 X1 I Hollow Metal Door RETAIL 15 Roof Wood 1,920 0.034 0 0 X11 I B/U Roof R.30 Truss T -Bar RETAIL 16 lWall lWood 87 0.065 1 0 90 X1 JR-19Wall (W.19.2x6.16) RETAIL 17 Wall Wood 231 0.065 180 6 None 9 Wall (W.19.2x6.16) RETAIL 18 Door None 21 0.581 180 0.76 7.0 6.0 ow Metal Door RETAIL 19 Roof Wood 1,920 0.034 0 AOX 0.1 99.0 99.0 LB/URoof R.30 Truss T -Bar RETAIL 20 Wall Wood 27 0.065 0 9 Wall (W.19.2x6.16) IRETAIL FENESTRATION SURFACES 11 None Site Assembled Glazing Check box It Building is - 100,000 sgft of CFA and - 10,000 sqft vertical glazing then NFRC Certification is required. Fnllnw NFRr inn -RR Prnrprliirac nnrl ciihmi4 KIFRr I nhcl r'crfi£rnfn Cnrm # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location I Comments 1 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 2 Window 346 0.720 0 0.60 Double Mtl Tinted Default RETAIL 3 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 4 Window 120 0.720 0 0.60 Double Mtl Tinted Default RETAIL 5 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 6 Window 123 0.720 0 0.60 Double Mtl Tinted Default RETAIL 7 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 8 Window 123 0.720 0 0.60 Double Mtl Tinted Default RETAIL 9 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 10 Window 183 0.720 0 0.60 Double Mtl Tinted Default RETAIL 11 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 12 Window 183 0.720 0 0.60 Double Mtl Tinted Default RETAIL 13 Window 42 0.870 270 0.59 Double Mtl Tinted Default RETAIL 14 Window 133 0.720 270 0.60 Double Mtl Tinted Default RETAIL 15 Window 42 0.870 270 0.59 Double Mtl Tinted Default RETAIL EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. H t. Right Fin Dist. Len. Hat. 1 None 0.76 2 None 0.76 3 None 0.76 7.0 6.0 6.0 3.0 5.0 5.0 4 None 0.76 10.0 16.2 6.0 0.1 0.0 0.0 5 None 0.76 7.0 6.0 6.0 3.0 4.0 4.0 6 None 0.76 10.0 16.5 6.0 0.1 0.0 0.0 7 None 0.76 7.0 6.0 3.5 3.0 99.0 99.0 8 None 0.76 10.0 16.5 3.5 0.1 99.0 99.0 9 None 0.76 10 None 0.76 11 None 0.76 12 None 0.76 13 None 0.76 7.0 6.0 5.0 3.0 5.0 56.0 14 None 0.76 10.0 17.5 4.0 0.1 0.0 50.0 15 None 0.76 7.0 6.0 5.0 3.0 24.0 38.0 Run Initiation Tome: 05/21/03 10:00:34 Run Code: 1053536434 EnergyPro 3.1 By Energysoft User Number. 2366 Job Number. 323 Page:6 of 25 ENVELOPE COMPLIANCE SUMMARY Performance ENV-] PROJECT NAME DATE THE CENTER AT LA QUINTA 5/21/2003 OPAQUE SURFACES Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments 16 Window 126 0.720 270 Surface Framing # Type Type Act. Area U -Fac. Azm. Tilt Solar Gains y/N Form 3 Reference Location/ Comments 21 Wall Wood 231 0.065 180 90 X1 I R-19 Wall W.19.2x6.16 RETAIL 22 Door None 21 0.581 180 90 X1 I Hollow Metal Door RETAIL 23 Roof Wood 1,920 0.034 0 0 X B/U Roof (R.30 Truss) T -Bar RETAIL 24 Wall Wood 27 0.065 0 90 R-19 Wall (W.19.2x6.16) RETAIL 25 Wall Wood 231 0.065 180 90 42 0.870 R-19 Wall W.19.2x6.16 RETAIL 26 Door None 21 0.581 180 90 X Hollow Metal Door RETAIL 27 Roof Wood 799 0.034 0 0 RETAIL B/L) Roof R.30 Truss T -Bar RETAIL 28 Wall Wood 65 0.065 270 1 90 X R-19 Wall (W.19.2x6.16) RETAIL 29 Roof Wood 720 0.034 0 0 X11 I B/U Roof R.30 Truss T -Bar RETAIL 30 Wall Wood 72 0.065 270 90 X11 1,R-19Wall (W.19.2x6.16) RETAIL 31 Roof Wood 879 0.034 0 0 X11 I B/U Roof R.30 Truss).T-Bar RETAIL 32 Wall Wood 480 0.065 180 90 X11 JR-19Wall W.19.2x6.16 RETAIL 33 Wall Wood 66 0.065 270 90 X11 JR-19Wall .19.2x6.16 RETAIL 34 Roof Wood 801 0.034 0 0 X11 I B/U Roof R.30 Truss T -Bar RETAIL 35 Walt Wood 155 0.065 0 90 X11 I R-19 WallW.19.2x6.16 RETAIL 36 Wall Wood 90 0.065 270 90 X R-19 WaII .19.2x6.16 RETAIL 37 Roof Wood 1,600 0.034 0 0 X B/U Roof R.30 Truss T -Bar RETAIL 38 Wall Wood 92 0.065 0 90 0.76 R-19 Wall W.19.2x6.16 RETAIL 39 Wall Wood 219 0.065 180 90 R-19 Wall W.19.2x6.16 RETAIL 40 Door None 21 0.581 180 90 X Lj Hollow Metal Door RETAIL FENESTRATION SURFACES Site Assembled Glazing Check box if Building is - 100,000 sqft of CFA and - 10,000 sqft vertical glazing then NFRC Certification is required. Follow NFRC 100-S6 PrnrxdllrPS and suhmit NFRC I ahal CertifirntP Fnrm # Type Area U -Fac. Act. Azm. SHGC Glazing Type Location / Comments 16 Window 126 0.720 270 0.60 Double Mtl Tinted Default RETAIL 17 Window 42 0.870 270 0.59 Double Mtl Tinted Default RETAIL 18 Window 156 0.720 270 0.60 Double Mtl Tinted Default RETAIL 19 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 20 Window 283 1 0.720 0 1 0.60 Double Mtl Tinted Default RETAIL 21 Window. 42 0.870 270 0.59 Double Mtl Tinted Default RETAIL 22 Window 108 0.720 270 0.60 Double Mtl Tinted Default RETAIL 23 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 24 Window 106 0.720 0 0.60 Double Mtl Tinted Default RETAIL 25 Window 42 0.870 0 0.59 Double Mtl Tinted Default RETAIL 26 Window 143 0.720 0 0.60 Double Mtl Tinted Default RETAIL EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. H t. LExt.RExt. Dist. Len. H t. Right Fin- Dist. Len. H t. 16 None 0.76 10.b 16.8 5.0 0.1 9.0 32.0 17 None 0.76 7.0 6.0 5.0 3.0 43.0 18.0 18 None 0.76 10.0 19.8 5.0 01 36.0 10.0 19 None 0.76 7.0 6.0 6.0 3.0 5.0 5.0 20 None 0.76 10.0 16.2 6.0 0.1 0.0 0.0 21 None 0.76 7.0 6.0 6.0 3.0 4.0 4.0 22 None 0.76 10.0 15.0 6.0 0.1 0.0 0.0 23 None 0.76 24 None 0.76 25 None 0.76 26 None 0.76 Run Initiation 1 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 323 Page:7 of 25 ENVELOPE COMPLIANCE SUMMARY Performance ENVA PROJECT NAME _ THE CENTER AT LA QUINTA DATE 5/21/2003 OPAQUE SURFACES Surface Framing Act. # Type Type Area U=Fac. Azm. Solar Gains Tilt Y/N Form 3 Reference Location / Comments 41 Roof Wood —1,600 0.034 0 0 jX11 I B/Ll Roof R.30 Truss T -Bar RETAIL 42 Wall Wood 55 —0.065 0 90 X11 IR-19Wall W.19.2x6.16 RETAIL 43 Wall Wood 219 0.065 180 90 X R-19 Wall (W.19.2x6.16) RETAIL 44 Door None 21 0.581 180 90 X1 I Hollow Metal Door RETAIL EXTERIOR SHADING ## Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len._Hgt. Dist. Len H t. FENESTRATION SURFACES Site Assembled Glazing U cnecK oox a buming is — 10u,0uu sgtt of UFA and — 10,000 sgtt vertical glazing then NFRC Certification is required. Follow NFRC 100 -SB Procedures and submit NFRC Label Certificate Form- # Type Area U. -Fac.. Act. Azm. SHGC Glazing Type Location I Comments EXTERIOR SHADING ## Exterior Shade Type Window SHGC Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len._Hgt. Dist. Len H t. Run Initiation 1053536434 EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 323 Page:8 of 25 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 PROJECT NAME DATE THE CENTER AT LA QUINTA 5/21/2003 INSTALLED LIGHTING SCHEDULE I AMac I 92AI I ACTC II Luminaire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # watts Per LamP DESCRIPTION # Lamp + Ballast Total Watts # Watts 4 4 It Fluorescent T8 Ma EE F 2T8 4 32 Ma netic Energy Efficient 2. 197 140.0 27,580 60w Wall Mount Incandescent 60W 60 No Ballast 12 60.0 720 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 28,300 Meets Total 28,300 ❑ Efficacy and Control Requirement of §130(c) Portable Lighting (From LTG -1) 3,171 Less Control Credit Watts (From LTG -3) ❑ Control Requirements of §131(f) Adjusted Actual Watts 31,471 MANDATORY AUTOMATIC CONTROLS NOTE TO FIELD CONTROL LOCATION CONTROL I I CONTROL TYPE I LUMINAIRES CONTROLLED NOTE TO (Room # or Dwg. #) IDENTIFICATION (Occupant, Daylight, Dimming, etc.) I— TYPE I# OF LU FIFI t1 NOTES TO FIELD - For Building Department Use Only Run Initiation Time: 05/21/03 10:00:34 Run Code: 1053536434 EnergyPro 3.1 By Energysoft User Number. 2366 Job Number. 323 Page:9 of 25 rA LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 PROJECT NAME THE CENTER AT LA QUINTA DATE 5/21/2003 TABLE 1A - PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE ROOM # OR ZONE ID DEFAULT W/s ft AREA SF TOTAL WATTS. B X C RETAIL 0.2 3,840 768 RETAIL RETAIL 0.2 0,2 9,600' 2,416 1,920 _ 483 LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Descriotion FIXT. FIXTURE (SF) AREAS (D x E) (C x E) TOTAL 15,856 3,171 TABLE 1 B - PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET Tenant # 11 1,600 1 1,600 A] a o a a o 0 LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Descriotion FIXT. FIXTURE (SF) AREAS (D x E) (C x E) Tenant # 4 801 1 801 Tenant # 11 1,600 1 1,600 Tenant # 10 1,600 1 1,600 TOTAL4001 0 ROOM # TOTAL AREA OR ZONE ID (SF) TOTAL 0 BUILDING SUMMARY - PORTABLE LIGHTING Designer needs to provide detailed documentation that the lig] level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+14-) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 19,857 3,171 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Paoe:10 of 25 1 CIERTIFICATE OF COMPLIANCE Performance MECH-1 PROJECT NAMEDATE THE CENTER AT LA QUINTA 5/21/2003 SYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECONOMIZER TYPE DESIGN O.A. CFM MECH-3, COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT.INSULATION PROTECTED? HEATING DUCT LOCATION R -VALUE COOLING DUCT LOCATION R -VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS DHW Heater PACKAGE # 12 A. B PACKAGE 5,6,7,8 9 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Electric Res 99% n/a n/a AO SMITH ELJF-06' Yes Yes n/a n/a n/a n/a n/a Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem Constant Tem n/a Outside Air Measure Auto No Economizer 960 cfm Gas Furnace 82% AFUE Packaged DX 8.9 EER BRYANT 558FPX/FEX090- AA Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating & Cooling Require n/a n/a n/a Constant Volume No No Constant Tem Constant Temp n/a Air Balance . Gravity No Economizer 2400 cfm Gas Furnace 82% AFUE Pack aged DX 8.9 EER BRYANT 558FPX/FEX090- AA Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No CODE TABLES: Enter code from table below into columns above. NOTE TO FIELD HEAT PUMP THERMOSTAT? Y: Yes N: No TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch 0: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance C: Outside Air Cert. M: Out. Air Measure D: Demand Control N: Natural A: Auto G: Gravity A: Air W: Water N: Not Required EC: Economizer Control See Section 144 e 3 Enter Outdoor Air CFM. Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPEIDUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE Run Initiation Time: 05/21103 10:00:34 Run Code: 1053536434 EnergyPro,3.1 By EnergySoft User Number. 2366 Job Number. 323 Page: 11 of 25 CERTIFICATE OF COMPLIANCE Performance MECH-1 'ROJECT NAMEDATE THE CENTER AT LA QUINTA 5/21/2003 (SYSTEM FEATURES . SYSTEM NAME TIME CONTROL Programmable Switch SETBACK CONTROL Heating & Cooling Required n/a ISOLATION ZONES HEAT PUMP THERMOSTAT? n/a ELECTRIC HEAT? n/a FAN CONTROL Constant Volume VAV MINIMUM POSITION CONTROL? No SIMULTANEOUS HEAT/COOL? :No HEATING SUPPLY RESET Constant Tem COOLING SUPPLY RESET Constant Temp HEAT REJECTION CONTROL n/a VENTILATION Air Balance OUTDOOR DAMPER CONTROL Auto ECONOMIZER TYPE No Economizer DESIGN O.A. CFM MECH-3, COLUMN I 604 cfm HEATING. EQUIPMENT TYPE Gas Furnace HEATING EQUIPMENT EFFICIENCY 80% AFUE COOLING EQUIPMENT TYPE Packaged DX COOLING EQUIPMENT EFFICIENCY 9.7 SEER / 8.5 EER MAKE AND MODEL NUMBER BRYANT 580FJV060 PIPE INSULATION REQUIRED? Yes PIPE/DUCT INSULATION PROTECTED? Yes HEATING DUCT LOCATION R -VALUE Ducts in Attic 4.2 COOLING DUCT LOCATION R -VALUE Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Tem .Constant Temp n/a Air Balance Auto No Economizer 200 cfm Gas Furnace 80% AFUE Packaged DX 9.0 EER BRYANT 5800FFPV/FEV072- Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No Programmable Switch Heating_Ai Cooling Require n/a n/a n/a Constant Volume No No Constant Tem Constant Temp n/a Air Balance Auto No Economizer 800 cfm Gas Furnace 80% AFUE Packaged DX 9.0 EER BRYANT 5800FFPV/FEV072- Yes Yes Ducts in Attic 4.2 Ducts in Attic 4.2 No NOTE TO FIELD CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? I I TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL Y: Ye! N: N< PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPA S: Prog. Switch H: Heating Enter Number of 1: Inlet Vanes 0: Occupancy C: Cooling Isolation Zones. P: Variable Pitch Sensor. B: Both V: VFD M: Manual Timer 0: Other C: Curve VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A: Auto A: Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. M: Out. Air Measure N: Not Required Note: This shall be no D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Page:12 of 25 1 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 PROJECT NAME THE CENTER AT LA QUINTA DATE 5i2�i2oo3 CHILLER AND TOWER SUMMARY BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Efficiency Tons PUMPS Blow -Through Equipment Name Equipment Type Qty. Tot Qty , GPM BHP Motor Eff. Drive Eff. Pump Control Constant Volume Blow -Through 1,995 1.00 82.5% 100.0% none BRYANT 580FPV/FEV072 AA Constant Volume Blow -Through 2,400 1.001. 82.5% 97.0% none DHW BOILER MMARY Energy Factor or Recovery Efficiency Standby Loss or Pilot TANK INSUL. Ext R -Val: System Name System Type Distribution Type Qty Rated Input (Gals.) Vol. O SMITH ELJF-06' Storage Elec. Point of Use 12 5,120 6 0.95 n/a n/a CENTRAL SYSTEM RATINGS HEATING COOLING System Name BRYANT 558FPX/FEX090 _System Type Packaged DX _Qty_ 7 _Output_ 147,600 Aux. kW_ 0.0 _Eff. 82% AFUE _Output 85,000 Sensible 59,50 _Efficiency EER _ Economizer Type _ No Economizer BRYANT 580FJV060 Packaged DX g . 3 49,000 0.0 80% AFUE 57,000 I8.9 39,900 9.7 SEER / 8.5 EER No Economizer BRYANT 580FPV/FEV072 AA Packaged DX 3 49,000 0.0 80% AFUE 72,000 50,40 .0 EER No Economizer CI IPPI V FAN PWTIIPN WAW System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. BRYANT 558FPX/FEX090 AA Constant Volume Blow -Through 3,000 1.50 84.0% 97.0% none BRYANT 580FJV060 Constant Volume Blow -Through 1,995 1.00 82.5% 100.0% none BRYANT 580FPV/FEV072 AA Constant Volume Blow -Through 2,400 1.001. 82.5% 97.0% none o6uo EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Pane: 13 of 25 1 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 PROJECT NAME THE CENTER AT LA QUINTA ZONE TERMINAL SUMMARY DATE 5/21 /20 VAV TERMINAL BOX TERMINAL FAN BASEBOARD Min. CFM Reheat CoilMoto Drive System T _pe Ratio Type DeltaT CFM BHP Eff. Eff. Type Output EXHAUS AN EXHAUSTFAN Room Name Qtv. CFM . BHP Motor Eff. Drive Eff. Room Name CFM BHP Motor Eff. Drive Eff. _qty. EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 323 Page:14 of 25 1 ]MECHANICAL VENTILATION MECH-3 I'I'(UJtCT NAME THE CENTE , AT LA QUINTA DATES/21/2003 MECHANICAL VENTILATION a a© o o a© o a o 0 EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 323 Page:15 of 25 1 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR. CFM VAV MIN. RATIO TRANS. FER AIR ZONE/SYSTEM COND. AREA (SF) CFM PER SF MIN. CFM (B x C) NO. OF PEOPLE CFM PER PERSON MIN. CFM (ExF) RETAIL 3,840 0.25 960 960 960 PACKAGE # 12 A. B Totall 960 960 RETAIL 9,600 0.25 2,400 2,400 2,400 PACKAGE 5,6,7,8,9 Total 2,400 2,400 RETAIL 2,416 0.25 604 6041 604 PACKAGE # 1, 2, 3 Totall 604 604 RETAIL 801 0.25 2001 200 200 PACKAGE 4 Total 200 200 RETAIL 3,200 0.25 800 800 800 PACKAGE 10 & 11 Totall 800 E800 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 323 Page:15 of 25 1 1PROPOSED CONSTRUCTION ASSEMBLY THE CENTER AT LA QUINTA W DESCRIPTION 0. w 1 Roofing, Built -Up 2 Plywood H co 4 L53 Z O — SKETCH OF ASSEMBLY CL1\/ f _ -,, i DATE 5/21/2003 ASSEMBLY NAME B/U Roof R.30 Truss T -Bar ASSEMBLY Floor TYPE Wall (check one) X Coiling 1 Roof FRAMING MATERIAL Wood FRAMING % 10 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) 7% (24" o.c. Floor/Cell.) SUBTOTA. Rc Rf R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Roofing, Built -Up 2 Plywood 0.620 Air Space 4 L53 Insulation, Mineral Fiber, R-30 9.158 Fiber Board, Tile and Lay -in Panels 6 0.06 7 0.36 s 0.75 9 0.10 INSIDE SURFACE AIR FILM CL1\/ f _ -,, i DATE 5/21/2003 ASSEMBLY NAME B/U Roof R.30 Truss T -Bar ASSEMBLY Floor TYPE Wall (check one) X Coiling 1 Roof FRAMING MATERIAL Wood FRAMING % 10 % Framing 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) 7% (24" o.c. Floor/Cell.) SUBTOTA. Rc Rf R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 03301 0.330 . 0.620 0.620 0.800 0.800 30.000 9.158 1.250 1.250 0.06 3.11 0.36 1.12 0.75 0.14 0.10 0.610 0.610 33.78 12.94 Off:? 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf) SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) 2.19 0.35 0.77 1.42 0.29 0.41 0.60 0.10 0.06 3.11 0.36 1.12 0.75 0.14 0.10 1 TOTAL HC 2 5 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0296 X 0.90 ] + [ 0.0773 x 0.10 1 / Rc 1 - (Fr -/.1100) 1 / Rf Fr% / 100 ASSEMBLY LI -VALUE I EnergvPro 3.1 By EnemvSoft User Number. 2366 Job Number. 323 Paae:16 of 25 1 �LIGHTING MANDATORY MEASURES LTG - NAME THE CENTER AT LA QUINTA DATE 5/21/2003 DESCRIPTIONDesigner Enforcement JX] § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and maybe an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. a § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override Is not to exceed 5,000 square feet FV § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified,'all alternate equipment shall be certified and installed as directed by the manufacturer. §-111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. CJ§ 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X❑ § 131(a)' Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. X❑ § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each dayiit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot Diagram of shading during different times of the year is included on plans. • § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. RX § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. U § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft . User Number. 2366 Job Number. 323 Page: 18 of 25 (MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH MM P OJ€CT NAS€ DATE THE CENTER AT LA QUINTA 5/21/2003 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies IX -1 §111, Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. �I § 115(a) Fan type central furnaces shall not have a pilot light § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be Installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as.offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint I_) § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. 122(a&b) Each space conditioning system shall be controlled by an individual thermostat 'that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable _ setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 2366 Job Number: 323 Page: 19 of 25 r [MECHANICAL MANDATORY MEASURES _ THF 9FNTFR AT LA QUINTA Part 2 of 2 MECH-MM DATE 5/21/2003 Description Designer Enforcement Ventilation �J §121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. U§ 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. FX]§ 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or 0 § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or § 121 (f)4 Another method approved by the Commission. Service Water Heating Systems I §113(b)2 If a circulating hot water system is installed, it shall have a control capable of . automatically turning off the circulating pump(s) when hot water is not required. u § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 11.0 degrees F. LJ § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water toa maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2:5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Page:20 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME _ _ THE CENTER AT LA QUINTA5/21/2003 SYSTEM NAME PACKAGE # 12 A. B _ DATE FLOOR AREA 3,840 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 2 COIL COOLING PEAK �OIML HTG. PEAK CFM Sensible Latent FSensible Total Room Loads 3,809 93,918 25,344 856 _ 32,127 Return Vented Lighting 0 Return Air Ducts 4,696 1,606 Return Fan 0 0 Ventilation 960 34,239 16,10 960 45,028 Supply Fan 0 0 Supply Air Ducts 4,696 1,606 TOTAL SYSTEM LOAD 137,5791 41,445 1=80,36J7 Heating System Output per System Total Output (Btuh) 147,600 295,200 Output (Btuh/sgft) 76.9 Cooling System Output per System 85,000 Total Output (Btuh) 170,000 Total Output (Tons) 14.2 Total Output (Btuh/sgft) 44'3 Total Output(sgftrron) 271,1 Air System HVAC EQUIPMENT SELECTION CFM per System 3,000 BRYANT 558FPXIFEX090-AA 142,502 11,326 295,200 Total Adjusted System Output 142,502 11,326 295,200 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pmt _ Jan 12 am_ Airflow (cfm) 6,000 Airflow (cfm/sgft) 1.56 Airflow (cfm/Ton) 423.5 Outside Air (%) 16.0 Outside Air (cfm/sgft) 0.25 _ Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 62.8 OF 62.8 OF 105.0 °F Outside Air Supply Air Ducts O 960 cfm Supply Fan Heating Coil 104.8 °F 6000 cfm ROOMS 69.8 OF 70.0 OF Return Air Ducts F DOLING SYSTEM PSYCHROMETRICS fAirstrearn Temperatures at Time of Cooling Peak 112.0 / 77.7 OF 84.1 / 66.1 OF 84.1/66.10F un 55.0/53.50F Outside Air 0 Supply Air Ducts 960 cfm Supply Fan Cooling Coil 55.7 / 53.8 OF 6000 cfm 44.7% R.H. ROOMS 78.7/63.6 °F 78.0 / 63.4 OF Return Air Ducts EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Page:21 of 25 f MVAC SYSTEM HEATING AND COOLING LOADS SUM --------------- MARY (PROJECT NAME - -----.__._...-___..---•—_:__-- THE DATE 5/21/2003 LOOSYsfW AktFR AREA I_ PACKAGE 5,6,7,8,9 _ 9,600 ERING CH (Number of Systems I� 5 Heating System Output per System Total Output (Btuh) 147,600 738,000 Output (Btuh/sgft) 76.9 Cooling System Output per System 85,000 Total Output (Btuh) 425,000 Total Output (Tons) 35.4 Total Output (Btuh/sgft) 44.3 Total Output (sgftlron) 271.1 Air System CFM per System 3,000 Airflow (cfm) 15,000 Airflow (cfm/sgft) 1.56 Airflow (cfmlron) 423.5 Outside Air (%) 16.0 Outside Air (cfm/sgft) 0.25 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM FSensible 8,864 218,567 61360 1,689 63,369 0 10,928 3,168 0 0 2,400 85,726 40,235 2,400 112,705 0 0 10.9281 3,168 A262391_103,_ 5951 182,410] BRYANT 558FPX/FEX090-AA 355,801 28,696 738,000 Total Adjusted System Output355,801 28,696 738,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 1 _ Jul 3 pmJ I Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 62.8 OF 62.8 OF 105.0 OF 0 Supply Air Ducts Outside Air 2400 cfm 104.8 OF Supply Fan Heating Coil 15000 cfm ROOMS 69.8 OF 70.0 °F K Return Air Ducts 4 DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.7 OF 84.0/66.1 OF 84.0/66.1 OF 55.0/53.5 OF O Supply Air Ducts- tOutside Air 2400 cfm Supply Fan Cooling Coil 55.7 / 53.8 OF 15000 cfm 44.7% R.H. ROOMS 78.7/63.6 OF 78.0 / 63.4 OF >% Return Air Ducts 4 I EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number: 323 Pace: 22 of 25 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME THE CENTER AT LA QUINTA DATE 5/21/2003 sYSTLlul NAME--- PACKAGE # 1, 2, 3 FLOORAREA 2,416 NGINEERING CHECKS SYSTEM LOAD Number of Systems 31 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent Total Room Loads 3,534 87,147 15,946 CFM I Sensible 746 27,985 Output per System -49.000 Total Output (Btuh) 147,000 Return Vented Lighting 0 Return Air Ducts 4,357 Return Fan 0 Ventilation 604 19,375 11,079 Supply Fan 0 Supply Air Ducts 4,357 TOTAL SYSTEM LOAD I 115,236 27,025 1,399 0 604 28,350 0 1,399 I 59,134 Output (Btuh/sgft) 60.8 Cooling System Output per System 57,000 Total Output (Btuh) 171,000 Total Output (Tons) 14.2 Total Output (Btuh/sgft) 70.8 Total Output (sgftlTon) 169.5 Air System HVAC EQUIPMENT SELECTION CFM per System 1,995 BRYANT 580FJV060 138,231 15,611 Total Adjuste138,231d System Output 15,611 (Adjusted for Peak Design Conditions) 147,000 147,000 Airflow (cfm) 5,985 Airflow (cfm/sgft) 2.48 Airflow (cfmrron) 420.0 Outside Air (%) 10.1 Outside Air (cfmisgft) F — _ 0.25 TIME OF SYSTEM PEAK I Jul 5 pm Jan 12 aml Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 65.4 OF 65.4 OF 105.0 of OSupply Air Ducts Outside Air 604 cfm Supply Fan Heating Coil 5985 cfm 104.8 of ROOMS 69.8 of 70.0 °F Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 108.6/76.9°F 81.7/64.7°F 81.7/64.7°F 55.0/53.5OF O Supply Air Ducts Outside Air 604 Cfm Supply Fan Cooling Coil 55.7 / 53.8 of 5985 cfm 43.3% R.H. ROOMS 78.7/ 63.2 of 78.0 / 62.9 of Return Air Ducts EnergyPro 11 By EnergySoft User Number: 2366 Job Number. 323 Page:23 of 25 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE THE CENTER AT LA QUINTA 5/21/2003 Slfs l E IVI NAM't FLOOR AREA PACKAGE 4 Rni Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM Sensible f 1,595 39,338 0 y_ 5,287 538 _ 20,189 1,967 1,009 0 0 200 6,405 3,767 200 9,362 0 0 1,967 1,009 49,677 9,054 31,570 BRYANT 580FPV/FEV072-AA 57,829 6,561 49,000 Total Adjusted System Output 57,829 6,561 x9,000 (Adjusted for Peak Design Conditions) _ TIME OF SYSTEM PEAK Jul 5 pml I Jan 12 ami HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) I 26.0 OF 66.0 OF 66.0 OF tj 105.0 °F e Supply Air Ducts Outside Air 200 cfm 104.6 °F Supply Fan Heating Coil 2400 cfm ROOMS 69.6 of 70.0 °F �% Return Air Ducts 4 (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 108.6/76.9°F 81.3/64.3°F 81.3/64.3°F55.0/53.5°F I Outside Air 0 200 Cfm Supply Fan 2400 cfm 78.8/63.0 °F Cooling Coil K Return Air Ducts `i Supply Air Ducts 55.8 / 53.9 of 42.8% R.H. ROOMS 78.0 / 62.8 of EnergyPro 3.1 By EnergySoft User Number. 2366 Job Number. 323 Page: 24 of 25 1 ,!-],HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Wkef NAME THE CENTER AT LA QUINTA DATE 5/21/2003 SYSTEM NAME FLOOR AREA PACKAGE 10 & 11 3,200 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 3,083 76,031 21,1201 593 22,248 0 3,802 11112 0 0 800 28,524 13,283 800 37,552 0 0 3,802 1,112 112,189 34,403 62,024 BRYANT 580FPV/FEV072-AA 120,004 10,606 98,000 Total Adjusted System Output 120,004 10,606 98,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK f Jul 3 pm I Jan 12 am 11EATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 1 26.0 OF 62.5 OF 62.5 OF 105.0 OF O Supply Air Ducts Outside Air 800 cfm 104.8 OF Supply Fan Heating Coil 4800 cfm ROOMS 69.8 OF 70.0 OF Return Air Ducts (COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak1 I 12.0/77.7°F 84.3/66.3°F 84.3/66.3°F 55.0/53.5°F _' r--1 S I A' D Outside Air 800 cfm 78.7/63.7 °F -y EnergyPn Supply Fan Cooling Coil 4800 cfm Return Air Ducts upp y it ucts. 55.7 / 53.8 of 44.9% R.H. ROOMS 78.0 / 63.4 OF 3.1 By EnergySoft User Number: 2366 Job Number. 323 Page:25 of 25