05-5540 (CSCS)P.O. BOX 1504
78-495 CALLE TAMPICO
., LA QUINTA, CALIFORNIA 92253
Application Number: /
Property Address:
APN:
Application description:
Property Zoning: '
Application valuation:
Applicant:
05-00005540
79795 HIGHWAY 111
649-030-087- -
NEW COMML - STORES
COMMERCIAL PARK
6600620
•t 4 4 "
l
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
& CUSTOMER SERVICE
Architect or Engineer:
Lic. No.: ---------------
-----------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B Li^censeN-o.:l 355353
Date) i%d ; Contractor: /(J� `Ow ?jraii.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I _ ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPER 11T
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/23/06
Owner:
COSTCO WHOLESALE CORP
999 LAKE DR P
ISSAQUAH, WA 98027
Contractor:
W L BUTLER CONSTRUCTION,7 GOODYEAR
IRVINE, CA 92618
(949)587-2206
Lic. No..: 355353
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier AEID INS Policy Number 71WC12012701
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall fo ith comply with those p ovisions.
Date: Applicant1911102Ct ,�, � *AS f^4 ;. .7 .7 b
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request.and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La ouinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is torr . I agree to comply with all
city and county ordinances and state laws relating to building construc 'on, and h e authorize representatives
of this county
to enter upon the above-mentioned property for in i purpos
Date: 5 �+`�� Signature (Applicant or Agent): Irw
Application Number . . . . 05-00005540
Permit
. . .
BUILDING PERMIT
Additional
desc .
Permit Fee
. . . .
14741.50
Plan Check
Fee '.
9581.98
'• Issue Date
. . . .
Valuation
. . . .
6600620
Expiration
Date
11/19/06
Qty Unit Charge
Per
Extension
BASE
FEE
3539.50
5601.00
----------------------------------------------------------------------------
2.0000
THOU BLDG
1,000,001 - UP
11202.00
Permit
. . .
ELEC-NEW COMMERCIAL
Additional
desc .
Permit Fee
. . . .
3007.92
Plan Check
Fee
751.98
Issue Date
. . . .
Valuation
0
Expiration
Date
11/19/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
149646.00
---------- -----------------------------------------------------------------
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
2992.92
Permit
. . .
GRADING PERMIT
Additional
desc . .
Permit Fee
15.00
Plan Check
Fee
.00
Issue Date
Valuation
0
Expiration
Date
11/19/06
Qty Unit Charge
Per
Extension
----------------------------------------------------------7-----------------
BASE
FEE
15.00
Permit
. . .
MECHANICAL
Additional
desc .
Permit Fee
. . . .
813.00
Plan Check
Fee
203..25
Issue Date
Valuation
. . . .
0
Expiration
Date
11/19/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
8.00
9.0000
EA MECH
FURNACE <=100K
72.00
13.00
11.0000
EA MECH
FURNACE >100K
143.00
4.00
9.0000
EA MECH•SUSP/WALL
HEATER
36.00
9.00
9.0000
EA MECH
B/C <=3HP/100K BTU
81.00
13.00
16.5000
EA MECH
B/C.>3-15HP/>100K-500KBTU
214.50
1.00
11.0000
EA MECH
AH >10K CFM
11.00
22.00
6.5000
EA MECH
VENT FAN
143.00
LQPERM[T
Application Number . . . . . 05-00005540
Permit . . . . . . MECHANICAL
Qty Unit Charge Per
Extension
2.00 6.5000 EA MECH EXHAUST HOOD
13.00
13.00 6.5000 EA MECH OTHER MECH EQUIPMENT
---------------------------------------------------------------------7------
84.50
Permit . . . PLUMBING
Additional desc .
Permit Fee . . . . 921.75 Plan Check Fee
230.44
Issue Date . . . . Valuation
0
Expiration Date 11/19/06
Qty Unit Charge Per
Extension
BASE FEE
15.00
87.00 6.0000 EA PLB FIXTURE
522.00
7.00 15.0000 EA PLB BUILDING SEWER
105.00
20.00 6.0000 EA PLB ROOF DRAIN
120.00
` 7.00 7.5000 EA PLB WATER HEATER/VENT
52.50
4.00 12.0000 EA PLB INTERCEPTOR
48.00
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
1.00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH
7.50
1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS
3.00
29.00 .7500 EA PLB GAS PIPE >=5
21.75
1.00 15.0000 EA PLB GAS METER
a
15.00
-------------------------------------------------------
Notes and Comments
COMMERCIAL RETAIL BUILDING (COSTCO),
149,646 SF(RETAIL = 144,572SF, TIRE
CENTER = 5074SF) M/S-3 OCCUPANCY, TYPE
VN CONSTRUCTION. UNLIMITED ALLOWABLE
AREA W/ 60 FT..YARDS AND FIRE SPRINKLER
SYSTEM PER CBC 505.2. 2001 CBC,CMC,CPC,
2004 CEC, 2005 ENERGY CODES. **THIS
PERMIT DOES NOT INCLUDE TEMPORARY
POWER, BLOCK WALLS, TRASH ENCLOSURES,
STORE FIXTURE/COUNTERS STORAGE RACKS,
GAS STATION AND SITE LIGHTING.**
NOTE: 2005 DIF FEES ASSESSED.BLDG AREAS
(149,646 SF) ADJUSTED INDIVIDUALLY IN
HTE TO REFLECT FEE INCREASE.
TRANS=52.668°%, CIV. CTR=64.211°%, fIRE
PROT.=40.625%, STREET MAINT=460.87%
----------------------------------------------------------------------------
Other Fees . . . . . . . ACCESSIBILITY PLAN REVIEW
958.20
ART IN PUBLIC PLACES -COM
32983.10•
DIF CIVIC CENTER - COMM
23344.77
LQPERMIT
Application Number . . . . . 05-00005540
Other.Fees . . . . . . . . . ENERGY REVIEW FEE 958.20
DIF FIRE PROTECTION -COMM 6734.07
STRONG MOTION (SMI) - COM 1386.13
1y DIF STREET MAINT FAC -COMM 15862.47
DIF TRANSPORTATION - COMM 393868.26
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 19499.17 .00 .00 19499.17
Plan Check Total 10767.65 9000.00 .00 1767.65
Other Fee Total 476095.2b .00 .00 476095.20
Grand Total 506362.02 9000.00 .00 497362.02
LQPERAIIT
Date 5/4/06
No. 28440
Owner KOMAR Investmenets
Address 23 Corporate Plaza Drive
City Newport Bch Zip 92660
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
�N�FIF_ps�'
BERMUDA DUNES r
Cn RANCHO MIRAGE Co
INDIAN WELLS �.
PALM DESERT y
dt}� LA QUINTA
�% NDIO yr��
L
649-030-086,87
Jurisdiction La Quinta
Permit #
Tract # Study Area
Type Commercial No. of Units 1
Lot # No. Street
Unit 1 79795 Highway 111
Unit 2
Unit 3
Unit 4
Unit 5
Comments
S.F.
149646 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
Lot # No. 'Street S.F.
At the present time, the Desert Sands Unified School District does not collect fees on garagestcarports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.42 X 149,646 S.F. or $62,851.32 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By OC/Heritage Bank - Tom Stanley Check No. 438283247
Name on the check Telephone 949.587.2234
Funding Commercial
By Dr. Doris Wilson
Superintendent
Fee collected /exempted Payment Recd }.
p Shard McG ey � y �_$
$62,851.32 .f3ver/under` -`
Signature c ``
NOTICE: Pursuant to Gove ent Code Section 66020(d)(1), this 'Il sery to notify you that the 90 -day approval period in which you may protest the fees o
r other payment identified above n to run from the date on 'ch building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever Is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original -Building Department/Applicant Copy - Applicant/Receipt Copy -Accounting
=r,
kn KLEINFELDER
An employee owned company
January 27, 2006
Project No.: 55403
Mr. Jeff Wilson
Mulvann,rG2 Architecture
1110 112 h Avenue NE, Suite 500
Bellevue, Washington 98004
Subject: Review of Project Plans and Specifications
Proposed Costco Wholesale Warehouse
79-795 Highway 111
La Quinta, California
References: Project Plans (Permit/Bid Set)
Costco Wholesale, Hwy 111 & Jefferson St., La Quinta, California
Prepared by MulvannyG2 Architecture, dated December 22, 2005
Project Manual, Costco Wholesale Site Work
Prepared by MulvannyG2 Architecture, dated December 15, 2005
Geotechnical Investigation, Proposed Costco Wholesale Warehouse
SWC of Jefferson Street and Highway 111, La Quinta, California,
Prepared by Kleinfelder, Inc., Dated May 23, 2005
Dear Mr. Wilson:
In accordance with your request, we have reviewed the referenced plans and
specifications for conformance to the recommendations presented in our geotechnical
investigation report the subject project (referenced above).
Based on our review, it is our professional opinion that the referenced plans and
specifications are in general conformance with the geotechnical recommendations
presented in the referenced report.
We trust this letter satisfies your current needs
questions or need additional information.
Respectfully submitted,
KLEINFELDER, INC.
`���yac w.>�o<<��
W ( No..2E —5 I rn
Eric W. Noel, P.E., GI
Senior Geotechnical E
cc: Mr. Ben Jones / Mulvanny.G2 Architecture
Mr: Andrew Franks / Kleinfelder, Inc.
Please contact me if you have any
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA 4 le B H
WENOEL\00-Projects\Costco Wholesale\La Quinta\Plan Rvw Ltr.Doc 1
Copyright 2006KIeinfelder, Inc.
KLEINFELDER 1370 Valley Vista Drive, Suite 150, Diamond Bar, CA 91765-3910 (909) 396-0335 (909) 396-1324 fax
Site Evaluation Report 7 December 6, 2005
Costco — La Quinta, California SEC Project No. 1905038-000
PART 2 - DEVELOPMENT REQUIREMENTS
Public Water Mains
A. The site will be served by a 24 -inch public water main from the existing Home
Depot parcel. A private fire protection loop will be extended to serve the Costco
parcel.
II. Fire Protection Water Supply Analysis
A. Based on the fire flow analysis conducted by the Coachella Valley Water District
and recorded April 4, 2005, the City distribution system will be capable of
supplying the following (refer to Attachment A to this report):
Static
Residual
Flow at Residual.
Pressure:
Pressure
Pressure
_.... (:psi) ...
.. ip'si).:......
.... .. (Jpm)'_......
92
88
1,216
B. Including a ten percent safety factor, the results of the fire flow analysis have
been reduced as follows:
Static
Residual
Flow'at`Residual
Pressure.
Pressure
Pressure
fps!
ipso).
.. i9pm)
83
79
1,216
C. In addition to the approximate 1,800 gpm sprinkler system design demand at an
approximate residual pressure of 55 psi, a fire flow requirement of 4,000 gpm at
20 psi will also required. This demand is based on a 50 percent reduction of the
fire flow requirements contained in the 2001 California Fire Code. The available
fire flow at 55 psi and 20 psi will be as follows:
Proiected Flow.
Projeeted' Flow at
55'psi:....
20 psi
1,750
5,388
D. Based on the hydraulic analysis, a fire pump and water storage tank will not be
necessary.
III. Water Department Requirements for Fire Protection Water
A. The private fire protection line will require a double detector check valve backflow
preventer assembly at the point of connection to the City distribution system.
Site Evaluation Report 7 December 6, 2005
Costco — La Quinta, California SEC Project No. 1905038-000
PART 2 -DEVELOPMENT REQUIREMENTS
I. Public Water Mains
A. The site will be served by a 24 -inch .public water main from the existing Home
Depot parcel. A private fire protection loop will be extended to serve the Costco
parcel.
II. Fire Protection Water Supply Analysis
A. Based on the fire flow analysis conducted by the Coachella Valley Water District
and recorded April 4, 2005, the City distfibution system will be capable of
supplying the following (refer to Attachment A to this report):
Static
Residual.
Flow at= Residual
Pressure
Pressure
Pressure
(psi) ..... ..
.. (PSS) .. ,
.. (Jp�?)
92
88
1,216
B. Including a ten percent safety factor, the results of the fire flow analysis have
been reduced as follows:
Static
Residual
Flow .at Residual
Pressure.
Pressure
Pressure
(PS! .. _.. .
.(Psi) .
(9pm:)
83
79
1,216
C. In addition to the approximate 1,800 gpm sprinkler system design demand at an
approximate residual pressure of 55 psi, a fire flow requirement of 4,000 gpm at
20 psi will also required. This demand is based on a 50 percent reduction of the
fire flow requirements contained in the 2001 California Fire Code. The available
fire flow at 55 psi and 20 psi will be as follows:
Projected Flow at
Projected Flow at
554psi
20 ;psi;
m::
ni
1,750
5,388
D. Based on the hydraulic analysis, a fire pump and water storage tank will not be
necessary.
III. Water Department Requirements for Fire Protection Water
A. The private fire protection line will require a double detector check valve backflow
preventer assembly at the point of connection to the City distribution system.
' Site Evaluation Report 7 December 6, 2005
Costco — La Quinta, California SEC Project No. 1905038-000
PART 2 - DEVELOPMENT REQUIREMENTS
I. Public Water Mains
A. The site will be served by a 24 -inch public water main from the existing Home
Depot parcel. A private fire protection loop will be extended to serve the Costco
parcel.
II. Fire Protection Water Supply Analysis
A. Based on the fire flow analysis conducted by the Coachella Valley Water District
and recorded April 4, 2005, the City distribution system will be capable of
supplying the following (refer to Attachment A to this report):
Static
Residual
Flow at: Residual
Pidssur.'e:
Pressure
Pressure
ps�� ......
(psi)
(9p .
m)... _ ...
92
88
1,216
B. Including a ten percent safety factor, the results of the fire flow analysis have
been reduced as follows:
Static
Residual
Flow:at`Adsidual
Pressure
Pressure.
Pressure
(PS!).
ipSi)
(9Pm)
83
79
1,216
C. In addition to the approximate 1,800 gpm sprinkler system design demand at an
approximate residual pressure of 55 psi, a fire flow requirement of 4,000 gpm at
20 psi will also required. This demand is based on a 50 percent reduction of the
fire flow requirements contained in the 2001 California Fire Code. The available
fire flow at 55 psi and 20 psi will be as follows:
Projected Flow at'
Projected' Flow'at
55�'psi� �
20i�psi
m;
m ........
1,750
5,388
D. Based on the hydraulic analysis, a fire pump and water storage tank will not be
necessary.
III. Water Department Requirements for Fire Protection Water
A. The private fire protection line will require a double detector check valve backflow
preventer assembly at the point of connection to the City distribution system.
Proudly serving the
unincorporated
areas of Riverside
County and the
Cities of:
Banning
Beaumont
Cahmesa
Canyon Lake
Coachella
Desert Hot Springs
:•
Indian Wells
Indio
Lake Elsinore
La Quinta
Moreno Valley
Palm Desert
Perris
Rancho Mirage
San Jacinto
Temecula
Board of Supervisors
Bob Buster,
District 1
John Tavaglione,
District 2
Jeff Stone,
District 3
Roy Wilson,
District 4
Marion Ashley,
District 5
RIVERSIDE COUNTY
FIRE DEPARTMENT
210 West San Jacinto Avenue • Perris, California 92570 • (951) 940-6900 • Fax (951) 940-6910
Date
City of La Quinta
Building Department
71 � WWO
The Riverside (,ount F. -De art is anting the Fire clearance for the following
location G�
Please caft if y ould have questions 760-863-8886
Respectfully
By
Terry DeSoucy
Fire Systems In ector
Certificate of Occupancy,
Lcoroa7IDG4�
G� OF 9► Y p Building & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 79-795 HIGHWAY 111
Use classification: COMMERCIAL RETAIL - COSTCO Building Permit No.: 05-5540
Occupancy Group: M/S-3 Type of Construction: V -N Land Use Zone: CR
Owner of Building: COSTCO WHOLESALE CORP. Address: 99 LAKE DRIVE
City, ST, ZIP: ISSAQUAH, WA 98027
�.� By: STEVE TRAXEL
Date: DECEMBER 21, 2006
Building Official
POST IN A CONSPICUOUS PLACE