Loading...
05-5540 (CSCS)P.O. BOX 1504 78-495 CALLE TAMPICO ., LA QUINTA, CALIFORNIA 92253 Application Number: / Property Address: APN: Application description: Property Zoning: ' Application valuation: Applicant: 05-00005540 79795 HIGHWAY 111 649-030-087- - NEW COMML - STORES COMMERCIAL PARK 6600620 •t 4 4 " l BUILDING & SAFETY DEPARTMENT BUILDING PERMIT & CUSTOMER SERVICE Architect or Engineer: Lic. No.: --------------- ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B Li^censeN-o.:l 355353 Date) i%d ; Contractor: /(J� `Ow ?jraii. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I _ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPER 11T VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/23/06 Owner: COSTCO WHOLESALE CORP 999 LAKE DR P ISSAQUAH, WA 98027 Contractor: W L BUTLER CONSTRUCTION,7 GOODYEAR IRVINE, CA 92618 (949)587-2206 Lic. No..: 355353 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier AEID INS Policy Number 71WC12012701 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall fo ith comply with those p ovisions. Date: Applicant1911102Ct ,�, � *AS f^4 ;. .7 .7 b WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request.and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is torr . I agree to comply with all city and county ordinances and state laws relating to building construc 'on, and h e authorize representatives of this county to enter upon the above-mentioned property for in i purpos Date: 5 �+`�� Signature (Applicant or Agent): Irw Application Number . . . . 05-00005540 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 14741.50 Plan Check Fee '. 9581.98 '• Issue Date . . . . Valuation . . . . 6600620 Expiration Date 11/19/06 Qty Unit Charge Per Extension BASE FEE 3539.50 5601.00 ---------------------------------------------------------------------------- 2.0000 THOU BLDG 1,000,001 - UP 11202.00 Permit . . . ELEC-NEW COMMERCIAL Additional desc . Permit Fee . . . . 3007.92 Plan Check Fee 751.98 Issue Date . . . . Valuation 0 Expiration Date 11/19/06 Qty Unit Charge Per Extension BASE FEE 15.00 149646.00 ---------- ----------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 2992.92 Permit . . . GRADING PERMIT Additional desc . . Permit Fee 15.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 11/19/06 Qty Unit Charge Per Extension ----------------------------------------------------------7----------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 813.00 Plan Check Fee 203..25 Issue Date Valuation . . . . 0 Expiration Date 11/19/06 Qty Unit Charge Per Extension BASE FEE 15.00 8.00 9.0000 EA MECH FURNACE <=100K 72.00 13.00 11.0000 EA MECH FURNACE >100K 143.00 4.00 9.0000 EA MECH•SUSP/WALL HEATER 36.00 9.00 9.0000 EA MECH B/C <=3HP/100K BTU 81.00 13.00 16.5000 EA MECH B/C.>3-15HP/>100K-500KBTU 214.50 1.00 11.0000 EA MECH AH >10K CFM 11.00 22.00 6.5000 EA MECH VENT FAN 143.00 LQPERM[T Application Number . . . . . 05-00005540 Permit . . . . . . MECHANICAL Qty Unit Charge Per Extension 2.00 6.5000 EA MECH EXHAUST HOOD 13.00 13.00 6.5000 EA MECH OTHER MECH EQUIPMENT ---------------------------------------------------------------------7------ 84.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 921.75 Plan Check Fee 230.44 Issue Date . . . . Valuation 0 Expiration Date 11/19/06 Qty Unit Charge Per Extension BASE FEE 15.00 87.00 6.0000 EA PLB FIXTURE 522.00 7.00 15.0000 EA PLB BUILDING SEWER 105.00 20.00 6.0000 EA PLB ROOF DRAIN 120.00 ` 7.00 7.5000 EA PLB WATER HEATER/VENT 52.50 4.00 12.0000 EA PLB INTERCEPTOR 48.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 1.00 7.5000 EA PLB OTHER BACKFLOW <=2 INCH 7.50 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 29.00 .7500 EA PLB GAS PIPE >=5 21.75 1.00 15.0000 EA PLB GAS METER a 15.00 ------------------------------------------------------- Notes and Comments COMMERCIAL RETAIL BUILDING (COSTCO), 149,646 SF(RETAIL = 144,572SF, TIRE CENTER = 5074SF) M/S-3 OCCUPANCY, TYPE VN CONSTRUCTION. UNLIMITED ALLOWABLE AREA W/ 60 FT..YARDS AND FIRE SPRINKLER SYSTEM PER CBC 505.2. 2001 CBC,CMC,CPC, 2004 CEC, 2005 ENERGY CODES. **THIS PERMIT DOES NOT INCLUDE TEMPORARY POWER, BLOCK WALLS, TRASH ENCLOSURES, STORE FIXTURE/COUNTERS STORAGE RACKS, GAS STATION AND SITE LIGHTING.** NOTE: 2005 DIF FEES ASSESSED.BLDG AREAS (149,646 SF) ADJUSTED INDIVIDUALLY IN HTE TO REFLECT FEE INCREASE. TRANS=52.668°%, CIV. CTR=64.211°%, fIRE PROT.=40.625%, STREET MAINT=460.87% ---------------------------------------------------------------------------- Other Fees . . . . . . . ACCESSIBILITY PLAN REVIEW 958.20 ART IN PUBLIC PLACES -COM 32983.10• DIF CIVIC CENTER - COMM 23344.77 LQPERMIT Application Number . . . . . 05-00005540 Other.Fees . . . . . . . . . ENERGY REVIEW FEE 958.20 DIF FIRE PROTECTION -COMM 6734.07 STRONG MOTION (SMI) - COM 1386.13 1y DIF STREET MAINT FAC -COMM 15862.47 DIF TRANSPORTATION - COMM 393868.26 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 19499.17 .00 .00 19499.17 Plan Check Total 10767.65 9000.00 .00 1767.65 Other Fee Total 476095.2b .00 .00 476095.20 Grand Total 506362.02 9000.00 .00 497362.02 LQPERAIIT Date 5/4/06 No. 28440 Owner KOMAR Investmenets Address 23 Corporate Plaza Drive City Newport Bch Zip 92660 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # �N�FIF_ps�' BERMUDA DUNES r Cn RANCHO MIRAGE Co INDIAN WELLS �. PALM DESERT y dt}� LA QUINTA �% NDIO yr�� L 649-030-086,87 Jurisdiction La Quinta Permit # Tract # Study Area Type Commercial No. of Units 1 Lot # No. Street Unit 1 79795 Highway 111 Unit 2 Unit 3 Unit 4 Unit 5 Comments S.F. 149646 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot # No. 'Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garagestcarports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.42 X 149,646 S.F. or $62,851.32 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Heritage Bank - Tom Stanley Check No. 438283247 Name on the check Telephone 949.587.2234 Funding Commercial By Dr. Doris Wilson Superintendent Fee collected /exempted Payment Recd }. p Shard McG ey � y �_$ $62,851.32 .f3ver/under` -` Signature c `` NOTICE: Pursuant to Gove ent Code Section 66020(d)(1), this 'Il sery to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above n to run from the date on 'ch building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever Is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy - Applicant/Receipt Copy -Accounting =r, kn KLEINFELDER An employee owned company January 27, 2006 Project No.: 55403 Mr. Jeff Wilson Mulvann,rG2 Architecture 1110 112 h Avenue NE, Suite 500 Bellevue, Washington 98004 Subject: Review of Project Plans and Specifications Proposed Costco Wholesale Warehouse 79-795 Highway 111 La Quinta, California References: Project Plans (Permit/Bid Set) Costco Wholesale, Hwy 111 & Jefferson St., La Quinta, California Prepared by MulvannyG2 Architecture, dated December 22, 2005 Project Manual, Costco Wholesale Site Work Prepared by MulvannyG2 Architecture, dated December 15, 2005 Geotechnical Investigation, Proposed Costco Wholesale Warehouse SWC of Jefferson Street and Highway 111, La Quinta, California, Prepared by Kleinfelder, Inc., Dated May 23, 2005 Dear Mr. Wilson: In accordance with your request, we have reviewed the referenced plans and specifications for conformance to the recommendations presented in our geotechnical investigation report the subject project (referenced above). Based on our review, it is our professional opinion that the referenced plans and specifications are in general conformance with the geotechnical recommendations presented in the referenced report. We trust this letter satisfies your current needs questions or need additional information. Respectfully submitted, KLEINFELDER, INC. `���yac w.>�o<<�� W ( No..2E —5 I rn Eric W. Noel, P.E., GI Senior Geotechnical E cc: Mr. Ben Jones / Mulvanny.G2 Architecture Mr: Andrew Franks / Kleinfelder, Inc. Please contact me if you have any CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA 4 le B H WENOEL\00-Projects\Costco Wholesale\La Quinta\Plan Rvw Ltr.Doc 1 Copyright 2006KIeinfelder, Inc. KLEINFELDER 1370 Valley Vista Drive, Suite 150, Diamond Bar, CA 91765-3910 (909) 396-0335 (909) 396-1324 fax Site Evaluation Report 7 December 6, 2005 Costco — La Quinta, California SEC Project No. 1905038-000 PART 2 - DEVELOPMENT REQUIREMENTS Public Water Mains A. The site will be served by a 24 -inch public water main from the existing Home Depot parcel. A private fire protection loop will be extended to serve the Costco parcel. II. Fire Protection Water Supply Analysis A. Based on the fire flow analysis conducted by the Coachella Valley Water District and recorded April 4, 2005, the City distribution system will be capable of supplying the following (refer to Attachment A to this report): Static Residual Flow at Residual. Pressure: Pressure Pressure _.... (:psi) ... .. ip'si).:...... .... .. (Jpm)'_...... 92 88 1,216 B. Including a ten percent safety factor, the results of the fire flow analysis have been reduced as follows: Static Residual Flow'at`Residual Pressure. Pressure Pressure fps! ipso). .. i9pm) 83 79 1,216 C. In addition to the approximate 1,800 gpm sprinkler system design demand at an approximate residual pressure of 55 psi, a fire flow requirement of 4,000 gpm at 20 psi will also required. This demand is based on a 50 percent reduction of the fire flow requirements contained in the 2001 California Fire Code. The available fire flow at 55 psi and 20 psi will be as follows: Proiected Flow. Projeeted' Flow at 55'psi:.... 20 psi 1,750 5,388 D. Based on the hydraulic analysis, a fire pump and water storage tank will not be necessary. III. Water Department Requirements for Fire Protection Water A. The private fire protection line will require a double detector check valve backflow preventer assembly at the point of connection to the City distribution system. Site Evaluation Report 7 December 6, 2005 Costco — La Quinta, California SEC Project No. 1905038-000 PART 2 -DEVELOPMENT REQUIREMENTS I. Public Water Mains A. The site will be served by a 24 -inch .public water main from the existing Home Depot parcel. A private fire protection loop will be extended to serve the Costco parcel. II. Fire Protection Water Supply Analysis A. Based on the fire flow analysis conducted by the Coachella Valley Water District and recorded April 4, 2005, the City distfibution system will be capable of supplying the following (refer to Attachment A to this report): Static Residual. Flow at= Residual Pressure Pressure Pressure (psi) ..... .. .. (PSS) .. , .. (Jp�?) 92 88 1,216 B. Including a ten percent safety factor, the results of the fire flow analysis have been reduced as follows: Static Residual Flow .at Residual Pressure. Pressure Pressure (PS! .. _.. . .(Psi) . (9pm:) 83 79 1,216 C. In addition to the approximate 1,800 gpm sprinkler system design demand at an approximate residual pressure of 55 psi, a fire flow requirement of 4,000 gpm at 20 psi will also required. This demand is based on a 50 percent reduction of the fire flow requirements contained in the 2001 California Fire Code. The available fire flow at 55 psi and 20 psi will be as follows: Projected Flow at Projected Flow at 554psi 20 ;psi; m:: ni 1,750 5,388 D. Based on the hydraulic analysis, a fire pump and water storage tank will not be necessary. III. Water Department Requirements for Fire Protection Water A. The private fire protection line will require a double detector check valve backflow preventer assembly at the point of connection to the City distribution system. ' Site Evaluation Report 7 December 6, 2005 Costco — La Quinta, California SEC Project No. 1905038-000 PART 2 - DEVELOPMENT REQUIREMENTS I. Public Water Mains A. The site will be served by a 24 -inch public water main from the existing Home Depot parcel. A private fire protection loop will be extended to serve the Costco parcel. II. Fire Protection Water Supply Analysis A. Based on the fire flow analysis conducted by the Coachella Valley Water District and recorded April 4, 2005, the City distribution system will be capable of supplying the following (refer to Attachment A to this report): Static Residual Flow at: Residual Pidssur.'e: Pressure Pressure ps�� ...... (psi) (9p . m)... _ ... 92 88 1,216 B. Including a ten percent safety factor, the results of the fire flow analysis have been reduced as follows: Static Residual Flow:at`Adsidual Pressure Pressure. Pressure (PS!). ipSi) (9Pm) 83 79 1,216 C. In addition to the approximate 1,800 gpm sprinkler system design demand at an approximate residual pressure of 55 psi, a fire flow requirement of 4,000 gpm at 20 psi will also required. This demand is based on a 50 percent reduction of the fire flow requirements contained in the 2001 California Fire Code. The available fire flow at 55 psi and 20 psi will be as follows: Projected Flow at' Projected' Flow'at 55�'psi� � 20i�psi m; m ........ 1,750 5,388 D. Based on the hydraulic analysis, a fire pump and water storage tank will not be necessary. III. Water Department Requirements for Fire Protection Water A. The private fire protection line will require a double detector check valve backflow preventer assembly at the point of connection to the City distribution system. Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning Beaumont Cahmesa Canyon Lake Coachella Desert Hot Springs :• Indian Wells Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris Rancho Mirage San Jacinto Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT 210 West San Jacinto Avenue • Perris, California 92570 • (951) 940-6900 • Fax (951) 940-6910 Date City of La Quinta Building Department 71 � WWO The Riverside (,ount F. -De art is anting the Fire clearance for the following location G� Please caft if y ould have questions 760-863-8886 Respectfully By Terry DeSoucy Fire Systems In ector Certificate of Occupancy, Lcoroa7IDG4� G� OF 9► Y p Building & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-795 HIGHWAY 111 Use classification: COMMERCIAL RETAIL - COSTCO Building Permit No.: 05-5540 Occupancy Group: M/S-3 Type of Construction: V -N Land Use Zone: CR Owner of Building: COSTCO WHOLESALE CORP. Address: 99 LAKE DRIVE City, ST, ZIP: ISSAQUAH, WA 98027 �.� By: STEVE TRAXEL Date: DECEMBER 21, 2006 Building Official POST IN A CONSPICUOUS PLACE