Loading...
07-0820 (CSCS) Title 24TITLE 24 REPORT Title 24. Report for: Komar Desert Center - Bldg B&C Hway 111 and Jefferson La Quinta, CA, 92253 Project Designer: SGPA Architecture Planning 1545 Hotel Circle South, -Studio 200 San Diego, CA, 92108 619.297.0131 Report Prepared By: Chris French LSW Engineers California, Inc. 5560 Ruffin Rd., #1 San Diego, CA 92123 (858) 268-3224 Job Number: 2006796.000 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE? // � MAY 3 12007 Date: 5/23/2007 ' [By The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: 2006796.000 User Number: 3137 ,- &?;� hlwy /// 1PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -11 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE Komar Desert Center - Bldg. B&C DATE OF PLANS 5/23/2007 PROJECT ADDRESS 11,598 Sq.Ft. Hway 111 and Jefferson La Quinta, CA BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Ienfiit ## SGPA Architecture Planning 619.297.0131 California as a civil engineer, mechanical engineer, or I am a licensed architect. DOCUMENTATION AUTHOR TELEPHONE Checked 6y/Date LSW Engineers California, Inc. 858 268-3224 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DATE OF PLANS SIGN BUILDING CONDITIONED FLOOR AREA 11,598 Sq.Ft. CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTELtMOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ❑ F-� 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGN DATE Chris French 57• 23-v7 The Principal Designer hereby certifys that the proposed bu ng design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. ❑ F-� 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures -1 Required F PRINCIPAL ENVELOPE DESIGNER - NAME SIG NAT LIC NO. G/ DAT SGPA Architecture Planning /�o O LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of This Sub Itra1 Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ECH-1, MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER - NAME SIG E NO. DATE Devin A. Abellon P.E.- LSW En ineers ]LIC. 31/-l8 S'•2-3 •L7 io I EnergyPro 4.3 by EnergySoft User Numbe:: 3137 Job Number: 2006796.000 Paoe:2 of 16 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-1� PROJECT NAME I DATE Desert Center - ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r ENERGY COMPONENT Standard Design 11,598 Proposed Design 1 Compliance Margin 9 Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: Percent better than Standard: 3.03 0.63 2.40""'"M0''- °MY' °t r 0 30 W +9012015018021024OZ7O3W93MW3964904so process) 466.41 379.89 86.53 119.58 159.34 -39.76 0.00 0.00 0.00 0.00 0.00 0.00 22.94 22.94 000 166.65 166.65 0.00 79.36 79.36 0.00'"` 153.48 153.48 0.00 1,011.46 962.30 49.16 4.9% ( 5.7% excluding Building Orientation Number of Stories Number of Systems Number of Zones E 90 deg Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 11,598 sqn. sqn. sqft. 1 201 9 11,598 15 Natural Gas E 2,396 sqn. Standard Proposed Orientation Gross Area Glazing Area Glazing Ratio 1.594 w/sqn. Prescriptive Env. Heat Loss Front Elevation E 2,396 sqn. 130 sqn. 5.4% Left Elevation s 1,626 sgft. 0 sqn. 0.0% Rear Elevation W 2,242 sqn. 1,026 sqn. 45.8% Right Elevation (N) 1,673 sqn. 823 sqn. 49.2% Total 7,936 sqn. 1,979 sqn. 24.9% Roof 11,598 sqn. sqn. 0.0% Standard Proposed Lighting Power DensityABtu/h-F w/sqn. 1.594 w/sqn. Prescriptive Env. Heat Loss Bram 3,206 Btu/h Prescriptive Env. Heat Gain 327,256 Btu/h-F Remarks: rtun imuauon i ime: U5/13/U/ U/:25:34 faun code: 1179930394 EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2005796.000 Paae:3 of 16 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Komar Desert Center - Bldg B&C DATE 5/23/2007 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sgft. Inst. . Ctrl. LPD Credits W/s ( o1 (W/sf)2 . Allowed.LPD .".Proc. =AreaTailored 'Loads /s 3 , :W/s 4: .(Vy/sf). RTU B1-1 Lease Space Retail Sales, Wholesale 1,719 "1.70 Restrm Corridor/Restroom/Support 49 '0.60 RTU B2-1 Restrm Condor/Restroom/Support 49 -0.60 Lease Space Retail Sales, Wholesale 1,771 '1.70 RTU B1-1 Lease Space Retail Sales, Wholesale 1,705 '1.70 Restrm Corridor/Restroom/Support 49 '0.60 RTU C1-1 & RTU C1-2 Lease Space Comp Bldg Restaurant 1,151 '1.20 16.000 RTU C1-3 Lease Space Comp Bldg Restaurant 672 "1.20 16.000 RTU C2-1 Restrm Corridor/Restroom/Support 49 '0.60 Lease Space Retail Sales, Wholesale 1,271 '1.70 Corridor Uncond. Corridor/Restroom/Support 201 '0.60 RTU C3-1 Restrm Corridor/Restroom/Support 49 '0.60 Lease Space Retail Sales, Wholesale 1,618 '1.70 ; RTU C4-1 Restrm Condor/Restroom/Support 49 *0.6001 Lease Space Retail Sales, Wholesale 1,398 *1.700. Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C (items marked with asterisk, see LTG -2 -C by others) (by others) 4. See LTG -6-C Items above requirespecial.documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST ..0 w,a� cnw�cemenr agency anuwu pay spmaiii anenaon co me nems specmeo in tms cnecKtlSt. l nese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation euhmitforl_ The Roof Roof R-30 is a CRRC Certified Roof with Reflectance = 0.30, Emittance = 0.75. The HVAC System "Carrier 50HJ0006-5 w/ DCV" includes an Economizer. This system has a cooling output < 75,000 Btuh or a supply cfm < 2500. The HVAC System "Carrier 50HJ0006-5 w/ DCV' is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The HVAC System "Carrier 50HJ0006-5 w/ DCV" Includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50HJ0007-5 w/ DCV" Includes an Economizer. This system has a cooling output < 75,000 Btuh or a supply cfm < 2500. The HVAC System "Carrier 50HJQ007-5 w/ DCV" includes Demand Control Ventilation per Standards Section 121. The HVAC System "Carrier 50HJQ008-5 w/ DCV" includes Demand Control Ventilation per Standards Section 121. The Zone "Lease Space" has a North/East/South Display Perimeter Credit of 87 ft. The Zone "Lease Space" has a West Display Perimeter Credit of 14 ft. The Zone "Lease Space" has a North/East/South Display Perimeter Credit of 87 ft. The Zone "Lease Space" has a West Display Perimeter Credit of 14 ft. The Zone "Lease Space" has a North/East/South Display Perimeter Credit of 87 ft. The Zone "Lease Space" has a West Display Perimeter Credit of 14 ft. 1— cnwpuunm ICawrCs ns"cu in rnrs penormance approacn appncauon nave specimcaoy been reviewers. Adequate written justification and documentation for their use have been provided by the applicant. or EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 PageA of 16-1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Komar Desert Center - Bldg B&C DATE 5/23/2007 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Inst. Area LPD (sgftJ (W/sf)1 ' Ctrl. Allowed LPD 'Proc. f Credits Arealored 'Loads '(1N/sf)2 /s 3 W/s: 4 Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C (items marked with asterisk, see LTG -2 -C by others) (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Zone "Lease Space" has a North/East/South Display Perimeter Credit of 87 ft. The Zone "Lease Space' has a West Display Perimeter Credit of 14 ft. The Zone "Lease Space" has a North/East/South Display Perimeter Credit of 87 ft. The Zone "Lease Space" has a West Display Perimeter Credit of 14 ft. The Zone "Lease Space" has a North/East/South Display Perlmeter Credit of 87 ft. The Zone "Lease Space' has a West Display Perimeter Credit of 14 ft. The Zone "Lease Space" has a North/East/South Displav Perimeter Credit of 87 ft. The Zone "Lease Space" has a West Dis la Perimeter Credit of 14 ft. The Zone "Lease Space" has a North/East/South Display Perimeter Credit of 87 ft. The Zone "Lease Space" has a West Display Perimeter Credit of 14 ft. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized I EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Paoe:5 of 16 1 CERTIFICATE OF COMPLIANCE ENV -1-C1 PROJECT NAME DATE Komar Desert Center - Bldg Bk 5/23/2007 OPAQUE SURFACES # Surface Tvpe Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Roof 1.71 0.036 R-30 R-0.0 0 0 New 02-A9 Lease Space 2 Wall 35 0.074 R-19 R-0.0 90 90 New 09-A5 Lease Space 3 Door Z 0.700 None R-0.0 90 90 New 28-A2 Lease S ace . 4 Wall 94 0.074 R-19 R-0.0 180 90 New 09-A5 Lease Space. 5 lWall 1 221 0.074 R-19 R-0.01 270 90 New 09-A5 Lease Space 6 Roof 4 0.036 R-30 R-0.0 0 0 New 02-A9 Restrm 7 Wall 11 0.074 R-19 R-0.0 90 90 New 09-A5 Restrm 8 Roof 4 0.036 R-30 R-0.0 0 0 New 02-A9 Restrm 9 Wall 11 0.074 R-19 R-0.0 90 90 New 09-A5 Restrm 10 Roof 1,77 0.036 R-30 R-0.0 0 0 New 02-A9 Lease Space 11 Wall 1 37 0.074 R-19 R-0.0 90 90 New 09-A5 Lease Space 12 Door 21 0.700 None R-0.0 90 90 New 28-A2 Lease Space 13 Wall 23a 0.074 R-19 R-0.0 270 90 New 09-A5 Lease Space 14 Roof 1,705 0.036 R-30 R-0.0 0 0 New 02-A9 Lease Space 15 Wall 364 0.074 R-19 R-0.0 90 90 New 09-A5 Lease Space 16 Door 22 0.700 None R-0.0 90 90 New 28-A2 Lease Space 17 Wall 23 0.074 R-19 R-0.0 270 90 New 09-A5 Lease Space 18 Roof 49 0.036 R-30 R-0.01 0 0 New 02-A9 Restrm 19 Wall 11 0.074 R-19 R-0.01 90 90 New 09-A5 Restrm 20 IRoof 1 1,151 0.036 R-30 R-0.01 0 0 New 02-A9 Lease Space N. E, A. R More than or equalto 10,000 sq.ft. of site -built fenestration area must Include a label certificate either Issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed In the contractor's Drolect office durInn construction and In the b ilding manaciers office after construction # lTvDe Area U -Fac? SHGCZ Act. Am. Cond. Stat. Glazing Type Location/ Comments 1 Window Rear W 223 1.1901116-A 0.83 116-B 270 New Storefront Lease Space 2 Window Rear W 227 1.190 116-A 0.83 116-B 270 New Storefront Lease Space 3 Window Rear W 223 1.190 116-A 0.83 116-B 270 New Storefront Lease Space 4 Window Right N 63 1.190 116-A 0.83 116-B 0 New Storefront Lease Space 5 Window Right N 127 1.190 116-A 0.83 116-B0 12.8 New 1 Storefront Lease Space 6 Window Rear W 130 1.190 116-A 0.83 116-B 270 New Storefront Lease Space 7 Window Rear W 223 1.190 116-A 0.83 116-B 270 New Storefront Lease Space 8 Window Right. N 190 1.190 116-A 0.83 116-B 0 New Storefront Lease Space 9 Window Right N 253 1.190 116-A 0.83 116-B 0 New Storefront Lease S ace 10 Window Front E 130 1.190 116-A 0.83 116-B 90 New Storefront Lease Space 11 Window Right N 190 1.190 116-A 0.83 116-B 0 New Storefront Lease Space (1 U -factor Type: 116-A Default Table from Standards, Table NF1 Default Tabfe from the ACM Manuel Appendix, NFRC Labeled value. (2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 10.0 22.3 14.5 0.1 15.0 4.1 0.0 0.0 0 5.0 11.1 0 2 None 0.76 10.0 22.7 14.5 0.1 15.0 15.0 3 None 0.76 10.0 22.3 14.5 0.1 15.0 15.0 4 None 0.76 10.0 6.3 28.0 0.1 0.0 32.0 5 None 0.76 10.0 12.7 6.0 0.1 20.0 0.1 6 None 0.76 10.0 13.0 12.8 0.1 10.0 10.0 7 None 0.76 10.0 22.3 14.5 0.1 10.0 10.0 8 None 0.76 10.0 19.0 6.0 0.1 0.0 14.0 9 None 0.76 10.0 25.3 7.0 0.1 15.0 0.0 10 None 0.76 10.0 13.0 7.0 0.1 0.1 10.1 11 None 0.76 10.0 19.0 7.0 0.1 10.8 15.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES CERTIFICATE OF COMPLIANCE ENV -1-C1 PROJECT NAME DATE Komar Desert Center - Bldg B&C 5/23/2007 OPAQUE SURFACES # Surface Tvpe Area U -Fac. Insulation Cay. Cont. Act. Azm. Tilt Cond: Status Joint Appendix IV Reference Location / Comments . 21 Wall 301 0.074 R-19 R-0.0 0 90 New 09-A5 Lease Space 22 Wall 521 0.074 R-19 R-0.0 270 90 New 09-A5 Lease Space 23 Roof 67 0.036 R-30 R-0.0 0 0 New 02-A9 Lease Space 24 Demisin 39 0.110 R-11 R-0.0 0 90 New 09-A2 Restrm faces Uncond. Corridor 25 Roof 4 0.036 R-30 R-0.0 0 1 0 New 02-A9 Restrm 26 Roof 1,271 0.036 R-30 R-0.0 0 0 New 02-A9 Lease Space 27 Wall 180 0.074 R-19 R-0.0 0 90 New 09-A5 Lease Space 28 Demising 10 0.110 R-11 R-0.0 0 90 New 09-A2 Restrm faces Uncond. Corridor 29 Roof 4 0.036 R-30 R-0.0 0 0 New 02-A9 Restrm 30 Demising 200 0.110 R-11 R-0.0 0 90 New 09-A2 Lease Space faces Uncond. Corridor 31 Wall 240 0.074 R-19 R-0.01 180 90 New 09-A5 Lease S ace 32 Door 2 0.7001 None R-0.0 180 90 New 28-A2 Lease Space 33 Roof 1,610 0.036 R-30 R-0.0 0 0 New 02-A9 Lease Space 34 Wall 19 0.074 R-19 R-0.0 0 90 New 09-A5 Lease Space 35 Wall 111 0.074 R-19 R-0.0 180 90 New 09-A5 Restrm 36 Wall 11 0.074 R-19 R-0.0 90 90 New 09-A5 Restrm 37 Roof 4 0.036 R-30 R-0.01 0 0 New 02-A9 iRestrm 38 Wall 65 0.074 R-19 R-0.01 90 1 90 1 New 09-A5 Lease Space 39 Wall 28 0.074 R-19 R-0.01 180 1 90 1 New 09-A5 Lease Space 40 Door 2 0.700 None I R-0.01 180 1 90 1 New 28-A2 Lease Space „y, . —r MON SURFACES an m equei w iv,uuu sq.n. or ace-oum ienestrauon area must mctuae a lapel cennlcate either Issued by NFRc or provide a CEG Default Label Certificate using the default LI -factors from Standards Table 116-A end B. Certificate shall be filed In the contractor's project office dudnq construction and in the buildina maneber's office after construction Stat. v -rector Type: r to -N verawt tante from siandaros, IaDte NI -1 uetamt table from the AGM Manual Appendix, NFRC Labeled value. 2 SH GC Type: 1168 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES vwl+��av vv�wrrry s m cnmata tunes z mrvugn w anu contains an encrosea space wim floor area greater men 25,000 112, a ceiling height greeter than 15 feet, and an LPD for general Li lighting of at least 0.5 Wrft2. See Section 143(c). If this box is chocked, ENV -C must be filled out. when submitting under the Prescriptive Compllanee Approach. 1 EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page:7 of 16 CERTIFICATE OF COMPLIANCE ENV -1-C1 PROJECT NAME DATE Komar Desert Center - Bldg B&C 5/23/2007 OPAQUE SURFACES tv, e, A. n thew, txisung, Anerea, Memoveo1 FENESTRATION SURFACES morn man or aqua, to I u,wu sq.u. or site-ouie renesuauon area must maube a iaosi cemucate enner Issues Dy M -KU or provide a utu uefau¢ Label cenWcete using the default LI -tactors from Standards Table 116-A and B. Certificate shall be filed In the conlrectors project office during construclion and in the building man.glel. ollice atter construction Act. Cond- Location/ # Tvoe Area U -Fac SHGC2 Azm- Stat- Glazine Tvne r.nmmoantc 1 U•taCldr type: 11ti-A Lietault Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES I I I ne proposea oulraing is in cremate zones a tnrougn 1s ana contains an enclosed space with floor area greater than 25,000 ft2, a coiling height greater than 15 feet, and an LPD for general LJ lighting of at least 0.5 WHt2. See Section 143(c). If this box Is checked, ENV -4•C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page:8 of 16 1 m�� • l� - 0�� ..Lease Space tv, e, A. n thew, txisung, Anerea, Memoveo1 FENESTRATION SURFACES morn man or aqua, to I u,wu sq.u. or site-ouie renesuauon area must maube a iaosi cemucate enner Issues Dy M -KU or provide a utu uefau¢ Label cenWcete using the default LI -tactors from Standards Table 116-A and B. Certificate shall be filed In the conlrectors project office during construclion and in the building man.glel. ollice atter construction Act. Cond- Location/ # Tvoe Area U -Fac SHGC2 Azm- Stat- Glazine Tvne r.nmmoantc 1 U•taCldr type: 11ti-A Lietault Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES I I I ne proposea oulraing is in cremate zones a tnrougn 1s ana contains an enclosed space with floor area greater than 25,000 ft2, a coiling height greater than 15 feet, and an LPD for general LJ lighting of at least 0.5 WHt2. See Section 143(c). If this box Is checked, ENV -4•C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page:8 of 16 1 CERTIFICATE OF COMPLIANCE MECH-I-C PROJECT NAME DATE Komar Desert Center - Bldg B&C 5/23/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and ooeratina and maintenance information meet the reauiremPntP of Sactinn in-innthi nnri Titla 9a Pnrt P STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are Installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 &2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV len volume controls Installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot waler systems that have a design capacity greater than or equal to 500,000 Btulhr. -Water-loop Heat Pump Controls Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than Shp. Equipment re uirin acceptance testing EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page:9 of 16 JAIR SYSTEM REQUIREMENTS . Part 1 of 2 MECH-2-CI PROJECT NAME DATE Komar Desert Center - Bldg B&C 5/23/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance T-24 Section AIR SYSTEMS Central or Single Zone RTU 81-1 RTU B2-1 RTU Bi -1 1 1 1 Reference on Plans or Specification 1 112(a) 7.70 HSPF 7.70 HSPF 7.70 HSPF 112 a 13.0 SEER / 11.0 EER 13.0 SEER / 11.0 EER 13.0 SEER / 11.0 EER 112 b Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121 b 358 cfm 366 cfm 526 cfm 121 c No No. No 121 c Yes Yes Yes 121 c 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122(f) Auto Auto Auto 122 n/a n/a n/a 123 124 R-8.0 R-8.0 R-8.0 144 a & b n/a n/a n/a 144 a & b 35,101 btuh 35,101 btuh 35,101 btuh 144 a & b n/a n/a n/a 144 a & b 46,981 btuh 47,102 btuh 45,838 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a Diff. Enth (Integrated) Diff. Enth (Integrated) Diff. Enth (Integrated) 144 f Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill In the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put °N/A° in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct In unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. I EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page: 10 of 16 1 JAIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-CI PROJECT NAME DATE Komar Desert Center - Bldg B&C 5/23/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance T-24 Section AIR SYSTEMS Central or Single Zone RTU C1-1 & RTU C1-2 RTU C1-3 RTU C2-1 2 1 1 Reference on Plans or Specification t 112(a) 2.20 COP 2.20 COP 7.70 HSPF 112(a) 11.0 EER 10.5 EER 13.0 SEER / 11.0 EER 112(b) Yes Yes Yes 112(c), 115(a) n/a n/a n/a 121(b) Yes Yes Yes 121 b .437 cfm 255 cfm 418 cfm 121 c No No No 121 c Yes Yes Yes 121(c). 122(e) Programmable Switch Programmable Switch Pro rammable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122(f) Auto Auto Auto 122 n/a n/a n/a 123 No 124 R-8.0 R-8.0 R-8.0 144 a & b n/a n/a n/a 144 a & b 86,191 btuh 54,650 btuh 35,101 btuh 144 a & b n/a n/a n/a 144 a & b 110,581 btuh 62,334 btuh 45,117 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c Yes Yes Yes 144 d No No No 144 a Diff. Tem (Integrated) Diff. Tem (integrated) Diff. Enth (Integrated) 144 f Constant Temp Constant Temp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 k No No No 1: For each central and single zone air systems (or group of similar units) fill In the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicabe, put "N/A' in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes If System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page:11 of 16 1 JAIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C� PROJECT NAME DATE Komar Desert Center - Bldg B&C I 5/23/2007 ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous HeaUCool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance T-24 Section AIR SYSTEMS, Central or Single Zone RTU C3-1 RTU C4-1 1 1 Reference on Plans or Specification t 112(a) 7.70 HSPF 7.70 HSPF 112(a) 13.0 SEER / 11.0 EER 13.0 SEER / 11.0 EER 112(b) Yes Yes 112(c), 115(a) n/a n/a 121(b) Yes Yes 121 b 505 cfm 450 cfm 121 c No No 121 c Yes Yes 121 c 122(e) Programmable Switch Programmable Switch 122(e) Heatinq & Cooling Required Heating & Cooling Required 122(f) Auto Auto 122(g) n/a Na 123 124 R-8.0 I R-8.0 144 a & b n/a n/a 144 a & b 35,101 btuh 35,101 btuh 144 a & b Na n/a 144 a & b 45,631 btuh 45,444 btuh 144 c Constant Volume Constant Volume 144 c 144(c) Yes Yes 144 d No No 144 a Diff. Enth (Integrated) Diff. Enth (Integrated) 144 f Constant Temp Constant Tem 144(l) Constant Temp Constant Temp 144 k No No 1: For each central and single zone air systems (or group of similar -units) fill in the reference to sheet number and/or specification section and paragraph number.where the required features are documented. If a requirement Is not applicable, put °N/A° In the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes If System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct seating Is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. Faun Initiation l Ime: 05123107 07:26:34 Run Code: 1179930394 EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Paae:12 of 16 MECHANICAL VENTILATION MECH-3-CI PROJECT NAME DATE Komar Desert Center - Bldg B&C I 5/23/2007 PRESCRIPTIVE REHEAT LIMITATION (Section 144 d ) MECHANICAL VENTILATION Section 121 b 2 AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F I G H 1 J K L M N ZONE/SYSTEM 0 NDS O. .. 0 Cl) a min ro - Q� ��3 % D n 0 C a c M 0 0- too -U ��n N N -n 6 m03 x 0 `" 7 m oma G1 a < OM�O T N D' N o 3 002 -n rn '� a to 9m x x A A n $ c w3d p _ 0 U) ; 2 •O ? D i 'tn 3 N D Lease Space 1,719 0.25 430 17.2 15.0 258 430 258 172 Restrm 49 0.15 7 7 100 RTU B1-1 Total 437 358 Restrm 49 0.15 7 7 100 Lease Space 1,77 0.25 443 17.7 15.0 266 443 266 177 RTU 132-1 Total 450 366 Lease Space 1,70q 0.25 426 56.31 7.6 4261 426 426 1 1 Restrm 49 0.151 7 7 100 RTU 131-1 Total 434 526 Lease Space 1,15 0.38 43751.8 8.41 437 437 437 RTU Ci -1 8 RTU C1 -2 Total 437 437 Lease Space 67 0.38 255 30.2 8.4 255 255 255 RTU C1-3 I Total 255 255 Restrm 49 0.15 7 7 100 Lease Space 1,27 0.25 318 42.0 7.6 318 318 318 RTU C2-1 Total 325 418 Restrm 49 0.15 7 7 100 Lease Space 1,616 0.25 405 53.4 7.6 405 405 405 RTU C3-1 I Total 412 505 Restrm 49 0.15 7 7 100 Lease Space 1,396 0.25 350 46.1 7.6 350 350 350 RTU C4-1 I I Total 357 450 C Minimum ventilation rete per Section 121 Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REQ'D V.A. is the larger of the ventliatlon rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than ore ual to H or use Transfer Air column N to make up the difference. J Design tan supply cfm Fan CFM x 30%; or K Condillon area It. sq.) x 04 cfnVft. sq.; or L Maximum of Columns H, J, K, or 300 cim M This must be less than orequal to Column L and greater that ore ual to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number. 3137 Job Number: 2006796.000 Page: 13 of 16 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Komar Desert Center - Bldg B&C DATE 5/23/2007 CHILLER AND TOWER SUMMARY System Type Distribution Type Efficiency Tons PUMPS Status Equipment Name Equipment Type Qty. FT-t—F I Qty jGPM BHP Motor Eff. Drive Eff. Pump Control MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation DHW/ BOILER SUMMARY Energy Factor I or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input Vol.Condition (Gals.) Status Ext. R -Val. MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type 9ty Output Aux. kW i Eff. Out ut Efficiency Condition Status I EconomizerType Carrier 50HJ0006-5 w/ DCV Packaged DX 6 56,200 0.0 7.70 HSPF 61,000 13.0 SEER / 11.0 EER New Diff. Enth (Integrated) Carrier 50HJQ007-5 w/ DCV Packaged DX 2 69,000 0. . 2.20 COP 76,000 11.0 EER New Diff. Temp (Integrated) Carrier 50HJQOOS-5 w/ DCV Packaged DX 1 87,500 O.0 2.20 COP 91,300 10.5 EER New Diff. Temp (Integrated) CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RFTURN FAN System Name Fan Type Motor Location CFM BHP Motor Eff. Drive Eff. CFM I BHP Motor Eff. Drive Eff. Carrier 50HJ0006-5 w/ DCV Constant Volume Draw -Through 2,000 1.07 82.5% 97.0% none Carrier 50HJQ007-5 w/ DCV Constant Volume Draw -Through 2,400 1.65 84.0% 97.0% none Carrier 50HJ0008-5 w/ DCV Constant Volume Draw -Through 3,000 1.44 82.5% 97.0% none Run InitiationTime: 7 7.26:34 Run Code: 1179930394 EnergyPro 4.3 by EnergySoft User Number: 3137 Job Number: 2006796.000 Page: 14 of 16 t t } n. - - • I rJ. A MECHANICAL EQUIPMENT DETAILS PROJECT NAME Knmar nnQzrt ( ontar _ Rlrin RP.(' Part 2of2 ME DATE _ . _ _ VAV TERMINAL BOX TERMINAL FAN Min. CFM Rehe t Coil Motor Drive System Type -Qty, Ratio Type DeltaT CFM BHP Eff. Eff. FXHAIISI FAN FXHAllqT FAN Room Name of . CFM BHP Motor Eff. Drive Eff. Room Name Ot . CFM BHP Motor Eff. Drive I Eff. B-1 Restrm 1.0 10C 0.10 49.0°/ 97.0% C2 Restrm 1.0 100 0.10 49.0°/ 97.0% B-2 Restrm 1.0 10C 0.10 49.00/ 97.0% Uncond. Corridor 1.0 100 0.10 49.0°/ 97.0% B-3 Restrml 1.0 1 10q 0.10 1 49.00/ 97.0%11 C3 Restrm 1.0 1 10 0.10 Run Initiation Time: 05/23/07 07:26:34 Run Code: 1 4.3 by EnergySoit User Number: 3137 Job Number: 2006796.000 Output 5ot16 MECHANICAL EQUIPMENT DETAILS Part 2 of 2 MECH-5-C� PROJECT NAME Knmar Ilacart f'anfnr - Rhin RfL(: DATE r, /0':) 10 An -7 VAV TERMINAL BOX TERMINAL FAN Min. CFM Reheat oil Motor Drive Sy -stem Type peltaT CFM BHP Eff. Eff. Type I Output EnergyPro 4.3 by EnergySoft User Number: 3137 Job Number: 2006796.000 Paae16 of 16 1 Room Name "'M BHP Motor I Eff. Drive Eff. Room Name Ot . CFM BHP Motor Eff. Drive Eff. C4 Restrm 1.0 10C 0.10 49.09/ 97.0% EnergyPro 4.3 by EnergySoft User Number: 3137 Job Number: 2006796.000 Paae16 of 16 1