Loading...
07-2956 (RC) Title 24TITLE 24 REPORT Title 24 Report for: TEA HOUSE TENANT 6 TH 79-630 / 79-710 HIGHWAY III LA QU I NTA, CA 92253 CITY OF LA QUINTq Project Designer: BUILDING & SAFETY DEPT. Fo PaROYVED Repo--- pared By: RAYMON: 0NG, P. E. PERFECT DESIGN'& E`NGINEERING, INC. 2416 W Valley AIN rr, A CA'91'903­ x('626)289-8808 I Job Number: R072266R BY By Date: J'l,9 �FCHAN�GP� \�v 6/5/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoff, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Jobl i=6t r: R072286M .f;-- User Number: 1919 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form ENV -MM. Envelope Mandatory Measures Form MECH-MM Mechanical Mandatory Measures HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads Room Cooling Coil Loads 1 2 3 12 13 15 17 19 21 23 EnergyPro 4.3 by EnergySoft Job Number: R072266R User Number: 1919 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME TEA HOUSE This Certificate of Compliance lists the building features and performance specif' eeded to c Title 24, Parts 1 and 6 of the DATE 6/5/2008 PROJECT ADDRESS DOCUMENTATION AUTHOR SIGNATURE DATE 1 15 TENANT 6 TH 79-630/79-710 HIGHWAY III LA QUINTA HIGH RISE RESIDENTIAL PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # DOCUMENTATION AUTHOR PERFECT DESIGN & ENGINEERING, INC. TELEPHONE (626) 289-8808 Checked by/Date Enforcement Agency Use L 02-22-2008 This Certificate of Compliance lists the building features and performance specif' eeded to c Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using t `e m c co Ii e` roach. 2,643 Sq.Ft. DOCUMENTATION AUTHOR SIGNATURE DATE 1 15 BUILDING TYPE ® NONRESIDENTIAL consistent with the other compliance forms and worksheets, with the specifica 0 i, other calculations submitted with thi HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION -�iT1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to ADDITION EXISTING + ADDITIOWALTERATION STATEMENT OF COMPLIANCE MEN F This Certificate of Compliance lists the building features and performance specif' eeded to c Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using t `e m c co Ii e` roach. The documentation preparer hereby certifies that the documentation is accurate a 63 7o DOCUMENTATION AUTHOR SIGNATURE DATE RAYMOND M. ZHONG P.E. "Y I The Principal Designer hereby certifys that the proposed building design re onstruction documents is consistent with the other compliance forms and worksheets, with the specifica 0 i, other calculations submitted with thi permit application. The proposed building as designed meets the energy effici ents contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. -�iT1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. R ❑ F—] 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ F-1 ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Required Forms 1 1 ds Submittal PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures tipFESSION Required Forms ME H-3 MECH-5 PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATUREc.� LryDATE PERFECT DESIGN & ENGINEERING �? o. 76 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-' PROJECT NAME DATE TEA HOUSE 6/5/2008 ANNUAL TDV ENE§ ENERGY COMPONENT Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Standard Design Proposed Design 0.50 425.78 107.83 0.00 0.00 69.80 72.98 30.51 91.54 Compliance Margin TOTALS: 929.65 798.95 130.70 L — - - u°nusa -yr i Percent better than Standard: 14.1% ( 15.6% excluding process) BUILDING COMPLIES Building Orientation Number of Stories Number of Systems Number of Zones (W)270deg (W)270d Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type 2,643 sqn. sgft. sgft. 1 0 3 2,643 2 I Natural Gas Glazing Ratio Standard Proposed Lighting Power Density 1.100 wisgft. 1.196 wisgft. Prescriptive Env. Heat Loss 470 Btum 662 Btum Prescriptive Env. Heat Gain 49,790 Btu/h-F 84,921 Btuth-F Remarks: Standard Building (Compliance) EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page:4 of 24 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (W) 441 sgft. 216 sgft. 48.9% Left Elevation (N) 600 sgft. 0 sgft. 0.0% Rear Elevation (E) 441 sqn. 0 sgft. 0.0% Right Elevation (S)i Total Roof 600 2,082 2,643 sqtt. sqn. sqn.sgft. 158 374 sgft. sgft. 26.3% Standard Proposed Lighting Power Density 1.100 wisgft. 1.196 wisgft. Prescriptive Env. Heat Loss 470 Btum 662 Btum Prescriptive Env. Heat Gain 49,790 Btu/h-F 84,921 Btuth-F Remarks: Standard Building (Compliance) EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page:4 of 24 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME TEA HOUSE DATE 6/5/2008 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPDCredits (W/sf)1 Ctrl. (W/sf? Allowed LPD Proc. Loads (W/sf) Area Tailored /s 3 (W/S4 AC -1 & 3 AREA (E) FLOOR PLAN Dining 2,043 0.773 1.500 AC -2 AREA (E) FLOOR PLAN Dining 600 2.633 1.500 Notes: 1. See LTG -2-C 2. See LTG -4-C (items marked with asterisk, see LTG -2 -C by others) 3. See LTG -5-C (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified In this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System "RHEEM HE80-130" is a Large Gas water heater with Pilot Loss = 0 btuh. r ne excepiionai reatures ustea in ims performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Pape:5 of 24 CERTIFICATE OF COMPLIANCE ENV -1-C (PROJECT NAME DATE TEA HOUSE 6/5/2008 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Wall 22E 0.069 R-21 R-0.0 270 90 Existing 09-A6 E FLOOR PLAN 2 Roof 2,04 0.025 R-38 R-0.0 0 0 Existing 01-A18 E FLOOR PLAN 3 Wall 44'0.069 (N) R-21 R-0.0 90 90 Existing 09-A6 E FLOOR PLAN 4 Wall 50C 0.069 R-21 R-0.0 0 90 Existing 09-A6 (E) FLOOR PLAN 5 Wall 441 0.069 R-21 R-0.0 180 90 Existing 09-A6 E FLOOR PLAN 6 Roof 60 0.025 R-38 R-0.0 0 0 Existing 01-A18 E FLOOR PLAN 7 Wall Left 0.069 R-21 R-0.0 270 90 Existing 09-A6 (E) FLOOR PLAN 8 Wall Right 0.069 R-21 R-0.0 90 90 Existing 09-A6 E FLOOR PLAN 9 Wall 10 0.069 R-21 R-0.0 0 90 Existing 09-A6 (E) FLOOR PLAN 10 lWall 0.069 R-21 R-0.0 180 90 Existing 09-A6 E FLOOR PLAN J, E, A. R (New, Existit More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default Ll -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's oroiect office during construction and In the buildinn manannrc nffice after cnnstmctinn # T e Area U -Fac' SHGC2 Act. Azm. Cond. Stat. Glazing Type Location/ Comments 1 Window Front W 216 1.2801116-A 0.80 116-B 270 Existing Sin le Metal Clear E FLOOR PLAN 2 Window Rear (E) 0 1.2801116-A 0.80 116-B 90 Existing Single Metal Clear (E) FLOOR PLAN 3 Window Left (N) 0 1.280 116-A 0.80 116-B 0 Existing Single Metal Clear (E) FLOOR PLAN 4 Window Right S 158 1.280 116-A 0.80 116-B 180 Existing Single Metal Clear E FLOOR PLAN 5 Window Front W 0 1.280 116-A 0.80 116-B 270 Existing Single Metal Clear E FLOOR PLAN 6 Window Rear (E) 0 1.280 116-A 0.80 116-B 90 Existing Single Metal Clear (E) FLOOR PLAN 7 Window Left (N) 0 1.280 116-A 0.80 116-B 0 Existing Single Metal Clear (E) FLOOR PLAN 8 Window Right S 0 1.280 116-A 0.80 116-B 180 Existin Single Metal Clear E FLOOR PLAN 1 U -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. 2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING #): Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 0.0 0.0 0.0 0.0 0.0 0.0 4 None 0.76 5 None 0.76 6 None 0.76 7 None 0.76 0.0 0.0 0.0 0.0 0.0 0.0 8 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater then 15 feet, and an LPD for general lighting of at least 0.5 Wfl12. See Section 143(c). If this box Is checked, ENV4-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page:6 of 24 CERTIFICATE OF COMPLIANCE MECH-I-C PROJECT NAME DATE TEA HOUSE 6/5/2008 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the reauirements of Section 10-1031b1 and Title 94 Part R STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required It the unit serves 5,000 R2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that most the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new waterioop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requirin acceptance testing EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page:7 of 24 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME DATE TEA HOUSE 6/5/2008 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS Central or Single Zone AC -1 & 3 AREA AC -2 AREA 2 1 Reference on Plans or Specification t 112(a) 79% AFUE 79% AFUE 112(a) 13.0 SEER / 13.0 EER 10.0 SEER / 10.0 EER 112 b n/a n/a 112(c), 115(a) n/a n/a 121(b) Yes Yes 121 b 1022 cfm 300 cfm 121 c No No 121 c No No 121(c), 122(e) Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required 122 Auto Auto 122 n/a n/a 123 124 R-8.0 R-8.0 144 a & b n/a n/a 144 a & b 141,480 btuh 70,740 btuh 144 a & b n/a n/a 144 a & b 83,471 btuh 39,425 btuh 144 c Constant Volume Constant Volume 144 c 144 c Yes Yes 144 d No No 144 a No Economizer No Economizer 144 Constant Temp Constant Tem 144(f) Constant Temp Constant Temp 144 k No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put °N/A° in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page:8 of 24 1 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C (PROJECT NAME DATE TEA HOUSE 6/5/2008 SYSTEM FEATURES 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, Hvdronic LooDS ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Equipment Efficiency Pipe Insulation PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation CHW and HHW Reset Controls WLHP Isolation Valves VSD on CHW, CW & WLHP Pumps > 5 HP DP Sensor Location T-24 Section Reference on Plans or Specification' 112(a) 123 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light 113 (a) 113 (b) 113 (c) 114 (a) 114 (b) 115 (c) 115 d Service Hot Water, Pool Heating DHW Heater 1 RHEEM HE80-130 95% n/a n/a n/a n/a Reference on Plans or Specification' 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. Run Initiation Time: 06/05/08 16:06:52 Run Code: 1212710812 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page•9 of 24 MECHANICAL VENTILATION MECH-3-C PROJECT NAME TEA HOUSE DATE 6/5/2008 PRESCRIPTIVE REHEAT LIMITATION Section 144 d ) MECHANICAL VENTILATION Section 121(b)2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C I D E F G H 1 J K L M N ZONE/SYSTEM 0 M 1n C.0 A�' c X D ;vn ' Q Jn m o 0 0 X M G n -n Np nM° Msnn°v X ;:v A0 03 a 'Ca (mnd m (E) FLOOR PLAN 2,043 0.50 1,022 68.1 15.0 1,022 1,022 1,022 AC -1 & 3 AREA Total 1,022 1,022 (E) FLOOR PLAN 60C 0.50 300 20.0 15.0 300 300 300 AC -2 AREA Total 300 300 C Minimum ventilation rate per Section 121, Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes for spaces without fixed seating. H Required Ventilation Air (REO'D V.A.) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G). 1 Must be greater than orequal to H, or use Transfer Air column N to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area (ft. sq.) x 04 cfm/ft. sq.; or L Maximum of Columns H, J, K, or 300 cfm M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column I) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column I) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page: 10 of 24 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME TEA HOUSE DATE 6/5/2008 CHILLER AND TOWER SUMMARY HP Type In Plenum Outside Buried Add 1/2" Insulation Eff iclency Tons PUMPS Equipment Name Equipment Type Qty. Tot. City GPM BHP Motor Eff. Drive Eff. Pump Control CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qtv1 Outout Aux. kW Eff. Outout Eff Iclency Condition Status Economizer Type CARRIER 48SD-060090 Packaged DX 2 70,740 0. 79%AFUE 60,00013.0 SEER/ 13.0 EER New No Economizer EXISTING A/C UNIT (5 TON). Packaged DX 1 DHW BOILER SUMMARY 0. Energy Standby TANK INSUL. Rated Vol. Condition Factor Loss or Ext. System Name System Type Distribution Type Ory Input I (Gals.) Status or RE Pilot R -Val. RHEEM HE80 130 Large Gas No Pipe Insulation 1 130,000 80 New 0.95 3.80% 12.0 Hot Water P mp Hot Water Piping Len h(ft) Control # HP Type In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qtv1 Outout Aux. kW Eff. Outout Eff Iclency Condition Status Economizer Type CARRIER 48SD-060090 Packaged DX 2 70,740 0. 79%AFUE 60,00013.0 SEER/ 13.0 EER New No Economizer EXISTING A/C UNIT (5 TON). Packaged DX 1 70,740 0. 79%AFUE 60,00010.0 SEER/ 10.0 EER Existing No Economizer ENVELOPE MANDATORY MEASURES ENV-MM NAME TEA HOUSE DATE 6/5/2008 DESCRIPTION Designer Enforcement ❑X §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. RX §118(c) All Insulating Materials shall be Installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X❑ § 117(a) All Exterior Joints and openings In the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. FX] §.116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). X❑ § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown In Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. a §118(e) Demising Walls In Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number: User Job Number: R072266R Page:12 of 24 FMECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM NAME TEA HOUSE DATE 6/5/2008 DESCRIPTION Desi ner Enforcement Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. RI § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X❑ § 124 Air handling duct systems shall be Installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: ❑X § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is Interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be Installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with Isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off Independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. R§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: R072266R Page: 13 of 24 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM NAME TEA HOUSE DATE 6/5/2008 Description Designer Enforcement Ventilation " 0 § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. FX] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. X❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers In all openings to the outside, except for combustion air openings. X❑ § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or X ` § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the Installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or X❑ § 121(64 Another method approved by the Commission. Service Water Heating Systems X❑ § 113(b)2 if'a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. X❑ § 113(c) Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number: User Job Number: R072266R Page: 14 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE TEA HOUSE 6/5/2008 SYSTEM NAME FLOOR AREA AC -1 & 3 AREA 2.043 Number of Systems 2 Heating System Output per System 70,740 Total Output (Btuh) 141,480 Output (Btuh/sgft) 69.3 Cooling System Output per System 60,000 Total Output (Btuh) 120,000 Total Output (Tons) 10.0 Total Output (Btuh/sgft) 58.7 Total Output (sgft/Ton) 204.3 Air System CFM per System 2,000 Airflow (cfm) 4,000 Airflow (cfm/sqft) 1.96 Airflow (cfmlron) 400.0 Outside Air (%) 25.5 Outside Air (cfm/sqft) 0.50 Note: values above given at ARI conditions W. :ATING SYSTEM PSYCHROME 26.0 OF 58.5 OF Outside Air 1022 cfm Supply Fan 4000 cfm 69.6 of )OLING SYSTEM PSYCHROME 111.0 / 77.6 of Outside Air 1022 cfm 75.1/68.2 0 F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM FSensible 137,205 16 717 85,374 CARRIER 48SD-060090 83,471 34,502 141,480 Total Adjusted System Output 83,471 34,502 141,480 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 4 pm Jan 12 am 58.5 OF 91.7 OF Heating Coil �% Return Air Ducts 4 at Time 84.2/70.7 OF 84.2/70.80F 0 64.6/63.50F �v Supply Fan 4000 cfm Cooling Coil h Return Air Ducts `{ Supply Air Ducts 91.3 of ROOMS 70.0 of Supply Air Ducts 65.7/63.9OF 73.5% R.H. ROOMS 74.0 / 67.9 of EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page: 15 of 24 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE TEA HOUSE 6/5/2008 SYSTEM NAME FLOOR AREA AC -2 AREA 600 SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible 'Latent CFM I Sensible 1,262 16,269 5,500 45 1,285 61.5/60.5 OF 0 O 813 64 0 0 300 12,010 1,826 300 14,038 0 0 813 64 29,9091 7,326 15 451 HVAC EQUIPMENT SELECTION EXISTING A/C UNIT (5 TON). 39,425 16,360 70,740 Total Adjusted System Output �9 425 16,360 7o,7ao (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 63.4 OF 63.4 OF 96.60F Outside Air Q Supply Air Ducts 300 cfm 96.6 of Supply Fan Heating Coil 2000 cfm ROOMS 70.0 of 70.0 of h Return Air Ducts `i DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 112.0/77.9 OF 80.0/67.7 OF 80.0/67.8 OF 61.5/60.5 OF O Supply Air Ducts Outside Air 300 cfm Supply Fan Cooling Coil 61.9 / 60.7 of 2000 cfm ROOMS 64.4% R.H. 74.4/65.7°F 74.0/65.6OF Return Air Ducts I EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page:16 of 24 ROOM LOAD SUMMARY PROJECT NAME TEA HOUSE DATE 6/5/2008 SYSTEM NAME AC -1 & 3 AREA FLOOR AREA 2,043 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE E FLOOR PLAN FLOOR PLAN 1 10,176 90,088 18,728 10,070 89,145 18,728 1,524 34,529 PAGE TOTAL 1 10,070 89,145 19,728 1,524 34,526 TOTAL 1 10,070 89,145 18,728 1,524 34,529 EnergyPro By EnergySoft User Number: User Job Number: R072266R Page: 17 of 24 ROOM LOAD SUMMARY 771 PROJECT NAME TEA HOUSE DATE 6/5/2008 SYSTEM NAME AC -2 AREA FLOOR AREA 600 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE E FLOOR PLAN FLOOR PLAN 1 1,265 16,309 5,500 1,262 16,269 5,500 45 1,285 PAGE TOTAL TOTAL 1 1,262 16,266 5,500 45 1,285 1 1,262 16,269 5,500 45 1,285 EnergyPro By EnergySoft User Number: User . Job Number: R072266R Page: 18 of 24 ROOM HEATING PEAK LOADS Project Title Date TEA HOUSE 6/5/2008 Room Information Design Conditions Room Name FLOOR PLAN Time of Peak Jan 12 am Floor Area 2,043 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr R-21 Wall 225.2 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 0.0690 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 684 215.8 1.2800 44 12,154 2,043.0 0.0250 44 2,247 441.0 0.0690 44 1,339 500.0 0.0690 44 1,518 442.3 0.0690 44 1,343 157.7 1.2800 44 8,882 perimeter = 198.1 0.7300 44 6,363 nems snown wim an astenSK l•1 aenote conouction through an interior surtace to another room. Page Total: 34 529 Infiltration: r 1.001 X 1.064 X 2 043 X 10.00 X 0.000 / 6] X � schedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 34,529 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page: 19 of 24 I ROOM HEATING PEAK LOADS 71 Project Title Date TEA HOUSE 6/5/2008 Room Information Desi n Conditions Room Name FLOOR PLAN Time of Peak Jan 12 am Floor Area 600 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr Roof 600.0 X X X X X X X x X x x X X x x X X x X x x X X x x X x X X x x X X x X x X X X 0.0250 X X X X X X X x X x x X X x x X X x X x x X X x x X x X X x x X X x X x X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 660 100.0 0.0690 44 304 perimeter= 10.0 0.7300 44 321 nems snown wim an astensK t-) aenote conauction tnrougn an interior sunace to another room. Page Total: 1 285 Infiltration: 1 1'.00 x i.osa x soo x 10go x o.000 /6] x 0 = 0 chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 1,285 EnergyPro 4.3 by EnergySoft User Number: 1919 Job Number: R072266R Page: 20 of 24 ROOM COOLING PEAK LOADS Project Title TEA HOUSE 53.6 Date 6/5/2008 ROOM INFORMATION DESIGN CONDITIONS Room Name FLOOR PLAN Time of Peak Sep 4 pm Floor Area 2,043 Outdoor Dry Bulb Temperature 106 OF Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 73 OF Conduction Wall Metal Clear Area 225.2 X 215.8 X 2,043.0 X 441.0 X 500.0 X 442.3 X 157.7 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain INDOWS U -Value 1 0.06901 DETD 1 X X X X X X X X X 53.6 = = = = = = = = = 20.7 43.4 32.1 30.1 40.1 20.7 (W) 215.8 Page Total Orientation Area X X X X X x x X X X SGF X x X X X X X X X X SC Weighting X X x X x X X X X X Factor = = = = = = = = = (W) 215.8 235 0.856 0.496 (E) 0.0 19 0.856 0.000 (N) 0.0 19 0.856 0.000 (S) 157.7 55 0.856 1.922 Page Total Btu/hr 833 5,726 2,215 976 1,040 1,225 4,184 is tss Btu/hr 21,550 0 0 14,273 35 823 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0c X 2,043 X 0.773 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 5,392 ccu ants 1.0c X 2,043 X 275 Btuh/occ. / 3 sgft/occ. X 1.00 = 18,728 Receptacle 1.0c X 2,043 X 0.500 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 3,486 rocess 1.0c x 2,043 X 1.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 10,459 Infiltration: 1.00 X 1.064 X 2 043 X 10.00 X 0.00 /601 X 38 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 90,088 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 2 043 x 275 Btuh/occ. / 30 sgft/occ. = 18 728 Receptacle 1.00 x x Watts/sgft x Btuh/Watt = Process 1.00 x 2,043 x 0.000 Watts/sgft x 3.413 Btuh/Watt = o Infiltration: x anx I z'0 J x x / 6] x _ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING PEAK LOADS Project Title TEA HOUSE Area Date 6/5/2008 ROOM INFORMATION DESIGN CONDITIONS Room Name FLOOR PLAN Time of Peak Jul 2 pm Floor Area 600 Outdoor Dry Bulb Temperature 111 `F Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 cl� Conduction B Roof Attic 1 Wall Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain S S U -Value 0.0250 0.0690 Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC (W) 0.0 190 0.856 (E) 0.0 46 0.856 (N) 0.0 46 0.856 (S) 0.0 68 0.856 DETD 1 71.1 = 36.9 = Page Total Weighting Factor x 0.000 = X 0.000 = X 0.000 = X 0.000 = X = X = X = X = X = X = Page Total Btu/hr 1,067 255 1 322 Btu/hr 0 0 0 0 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0c X 600 X 2.633 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 5,392 ccu ants 1.0c X 600 X 275 Btuh/occ. / 3 sqft/occ. X 1.00 = 5,500 ece tacle 1.0 x 600 X 0.50o Watts/sgft x 3.41 Btuh/Watt x 1.00 = 1,024 rocess 1.0 x 600 X 1.500 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 3,072 Infiltration: x i.o64 x soo x Height x o.00 /6] x chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,306 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 X 600 X 2751 Btuh/occ. / 30 sgft/occ. = 5 500 Receptacle 1.00 x x 0.000 Watts/sqft x Btuh/Watt = Process 1.00 X 600 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: x x 771 x x x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING COIL LOADS Project Title TEA HOUSE Area Date 6/5/2008 ROOM INFORMATION DESIGN CONDITIONS Room Name FLOOR PLAN Time of Peak Aug 4 pm Floor Area 2,043 Outdoor Dry Bulb Temperature 1119F Indoor Dry Bulb Temperature 74OFOutdoor Wet Bulb Temperature 78 9F Conduction 1 Wall Metal Clear Area 225.2 X 215.8 X 2,043.0 X 441.0 X 500.0 X 442.3 X 157.7 X X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0690 1.2800 Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC (W) 215.8 260 0.856 (E) 0.0 28 0.856 (N) 0.0 28 0.856 (S) 157.7 34 0.856 DETD 1 60.7 = 23.9 = 56.1 = 39.0 = 36.8 = 41.5 23.9 = Page Total Weighting Factor X 0.474 = X 0.000 = X 0.000 = X 2.043 = X = X = X = X = X = X = Page Total Btu/hr 944 6,592 2,866 1,185 1.270 1,268 4,817 18 941 Btu/hr 22,763 0 0 9,376 32 139 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr fights 1.0c x 2,043 X 0.773 Watts/sgft x 3.411, Btuh/Watt x 1.000 = 5,392 ccu ants 1.0c x 2,043 X 275 Btuh/occ. / 3 Sgft/OCC. x 1.00 = 18,728 Receptacle 11.0c x 2,043 X 0.500 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 3,486 rocess 1.0c X 2,043 X 1.500 Watts/sgft X 3.41 Btuh/Watt X 1.00 = 10,459 Infiltration: 1.00 X 1.064 X 2 043 X 10.00 X 0.00 / 60] X 38 = -Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 89,145 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x 2,0431 X 275 Btuh/occ. / 30 sgft/occ. = 18 728 Receptacle 1.00 x x Watts/sgft x Btuh/Watt Process 1.00 x 2,043 x 0.000 Watts/sgft x 3.413 Btuh/Watt = o Infiltration: x x x x /6] x Z_ chedule Air Latent Area Ceiling Height ACH pyy ROOM COOLING COIL LOADS Project Title TEA HOUSE Area Date 6/5/2008 ROOM INFORMATION DESIGN CONDITIONS Room Name FLOOR PLAN Time of Peak Jul 3 pm Floor Area 600 Outdoor Dry Bulb Temperature 112 OF Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 OF Conduction Roof Attic Area 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain TT U -Value 0.0250 0.0690 Orientation Area x X X X X X X X X X SGF X X X X x X X X X X SC (W) 0.0 242 0.856 (E) 0.0 41 0.856 (N) 0.0 41 0.856 (S) 0.0 45 0.856 DETD 1 67.8 = 38.4 = Page Total Weighting Factor X 0.000 = X 0.000 = X 0.000 = X 0.000 = X = X = x = X = X = X = Page Total Btu/hr 1,016 265 1281 Btu/hr 0 0 0 0 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor fights 1.0c X 600 X 2.633 Watts/sgft X 3.41 Btuh/Watt X 1.000 = 5,392 ccu ants 1.0c X 600 X 275 Btuh/occ. / 3 sgft/occ. X 1.00 = 5,500 eceptacle 1.0c X 600 x 0.500 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 1,024 rocess r1.0c X 600 X 1.500 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 3,072 Infiltration: I 1.00 x 1.064 X 600 X 10.00 x 0.00 /6] X 38 = chedule Air Sensible Area Ceiling Height ACH LT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,269 Sched. Btu/hr Latent Gain Frac. Area Heat Gain Occupants 1.00 x soo x 2751 Btuh/occ. / 3o sgft/occ. = 5 500 Receptacle 1.00 x x Watts/sqft x Btuh/Watt Process 1.00 X 600 x 0.000 Watts/sgft x 3.413 Btuh/Watt = 0 Infiltration: �� x Air 4,771 x x Ceiling xACH / 60] x I _