Loading...
BRES2017-0218 Evaluation Report11K[A._.,tIVL:U qUES " 199 SEP 2 5 2[ il7 Cm` OF UINTA Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid ThWMM� � 1ELoPMENr VELUX AMERICA, LLC. DECK MOUNT GLASS -GLAZED UNIT SKYLIGHTS CURB MOUNT GLASS -GLAZED UNIT SKYLIGHTS TUBULAR DAYLIGHTING DEVICES CSI Section: 08 62 00 Unit Skylights 1.0 RECOGNITION Verco America, LLC's Deck Mount Glass -Glazed Unit Skylights, Curb Mount Glass -Glazed Unit Skylights and Tubular Daylighting Devices recognized in this report have been evaluated for use .as glazed skylights. The structural performance, air and water tightness, operating forces, durability and thermal and optical performance properties of the Deck Mount Glass -Glazed Unit Skylights, Curb Mount Glass=Glazed Unit Skylights and Tubular Daylighting Devices were evaluated for compliance with the following codes: • 2015 and 2012 International Building Code! -'(IBC) 2015 and 2012 International Residential Code' (IRC) • 2015 and 2012 International Energy Conservation Code' (IECC) • 2016 California Building Code (CBC) — See attached Supplement 2.0 LIMITATIONS Use of the VELUX Deck Mount Glass -Glazed Unit Skylights, Curb Mount Glass -Glazed Unit Skylights and TubuIar Daylighting Devices recognized in this report is subject to the following. limitations: 2.1 VELUX Deck Mount Glass -Glazed Unit Skylights, Curb Mount Glass -Glazed Unit Skylights and Tubular Daylighting Devices shall be installed in accordance with the applicable code, the manufacturer's instructions, and this report. In the event of a conflict, the more restrictive governs. 2.2 Deck and curb mount glass -glazed unit skylights shall not be used in Type I or 11 construction, over acid fume - containing spaces, in wind-borne debris regions or where unusual loading is expected. 2.3 Deck and curb mount glass -glazed unit skylights that are set at an angle of less than 45 degrees from the horizontal shall be mounted at least 4 inches (102 mm) above the plane of the roof except for R-3 occupancies with a minimum roof slope of 3-units vertical in 12 units horizontal. 2.4 Light transmitting plastic of tubular daylightingdevices shall be mounted at Ieast 4 inches (102 mm) above the plane o.fthe roof except for R-3 occupancies with a minimum roof slope of 3-units vertical in 12 units or for buildings with a non -classified roof covering. 2.5 Aggregate area, separation and location of tubular daylighting devices shall be in accordance with IBC Sections 2606.7, 2610.5, 2610.6, 2610.7, 2610.8 and 803.1.1 for those occupancies within the scope of the IBC. 2.6 Installation of skylights and tubular daylighting devices shall be in accordance with IRC Section R308.6 for those occupancies within the scope of the IRC. 2.7 Edges of light transmitting plastic of tubular daylighting devices shall be protected by metal or noncombustible edge material except where non -classified roof coverings are permitted. 2.8 Electric motor -driven sash operators, in VSE, VSS, VCE and VCS skylights shall comply with the applicable electrical code requirements and are subject to approval of the code official. 3.0 DECK MOUNT GLASS -GLAZED UNIT SKYLIGHTS 3.1 UESES: VELUXO FS, VS, VSE and VSS No Leak SkylightsTM are unit skylights complying with IBC Section 2405.5 that provide natural light and views into the interior of building spaces. The skylights are intended for use on building roofs sloped from 3-units vertical in 12 units from the horizontal (25-percent slope) plane to 85 degrees from the horizontal plane. Each unit contains an integral supporting frame with continuous mounting flange intended for direct attachment to roofing substrate. VS, VSE and VSS skylights provide natural ventilation via an operable top -hinged sash. FS units arc fixed. The glass is continuously supported on all four sides. 3.2 DESCRIPTION 3.2.1 Insulati s 't 'L g lass units (IGU) e>7 ttt , �s 'ghts complying 1 p M^� 5A 101/I.S.2/A440- W � . are co tructed from a %i5ww 1 c coated tempered glass lite out Jsh e ) mm) hick laminated lass li less -steel spaces system for an verall ifcss f 5/x inch .9 mm). The urinated glass to inboar� ri crich (2.4 mm) t ick iat are each permanently b t d o e 30 o. 0-090 inch (0.8 or 2.3 mm) thick p nvi butyral (PVB) clear interlayer. When increased thermal performance is desired, an additional Low-E coating The product desc:dbelf it tllls Uniform Evalrrafien Survive (LIES) Report has been evaluated as an affemative material, design or method of construction in order to satisfy and comply vMh the Intent of the provisions of the code. as noted In this report and for al least aquivalence to thatprescnfled in the code in quality, strength, efrealivcness, fire resistance, durability and safely, as epMeble, in accordance with OC Section 104,11. This documanl shall only be taprOduced n Rs erbrety Copyright C+ 2017 by fntamational Assodalion of Plumbing and MerhaMcal Officials. All rights reserved. Printed in the United States Ph: 1-877-41ESRPT • Fax: 909.472-4171 web: www.unHorm-as.org • 4755 EastPhdadelphra Street, Ontario, calilarnia 91761-2816— USA Page 1 of 19 199 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 is applied on the interior glass surface of the IGU. The space between glass lites is filled with 95 percent argon gas. 3.2.2 Assembly Details: Condensation control gasketing for all skylight models directs accumulated water droplets from the inner glass surface to the exterior without compromising required air tightness. VELUX FS, VS, VSE and VSS skylights consist of several integrated components: one panel of flat IGU top -mounted onto an aluminum -clad wood sash (VS, VSE and VSS), or directly onto an aluminum -clad wood frame (FS). Top - hinged sash on any VS, VSE or VSS skylight is fastened to and supported on a similar aluminum -clad wood frame. Sash and frames are manufactured from white -finished pine wood having a nominal specific gravity of 0.47 and are covered on the weather -exposed sides with roll -formed aluminum cladding that is coated with Kynar and lacquer. Frames have mortised corners secured with adhesive and aligned and stabilized by a 1'/a inch (44.5 mm) long corner nail. A continuous galvanized steel mounting flange with mitered and welded comers is attached to the lower partof the frame and rests upon a foam isolation pad to interface with the mounting surface. Galvanized nails secure the flange to the frame every 9 inches (229 mm) or less. Only the VS, VSE and VSS frames have a support ledge all around the interior face, to which a gasket is stapled for a tight seal with the sash frame. The frames also support the fixed half of the extruded aluminum sash hinge on the top of the frame head, fastened with 1 inch (25.4 mm) long No. 8 screws spaced at 10 inches (254 mm) on center. VELUX VS, VSE and VSS skylight sashes also use a mortise joint corner construction with one 5/16 inch (7.9 mm) long staple at each corner. The rotating half of the extruded aluminum hinge is fastened with 1 inch (25.4 mm) long No. 8 screws spaced at 10 inches (254 mm) on center. The IGU is secured with hot -applied primary sealant bonded to roll formed aluminum glazing retaining profiles that are secured to the sash or frame using No. 8 stainless steel screws of various lengths (1 and 2-1/2 inches (25.4 and 63.5 mm) for VS, VSE and VSS and 1-1/4 inch (31.8 mm) for FS spaced every 9 inches (229 mm). All VS, VSE and VSS skylights are equipped with insect screens. VSE and VSS skylights employ an electric motor -driven sash operator with radio frequency remote control and have exterior sensors to automatically trigger the operator to close an open sash when rain droplets are present. VSS skylights use solar powered batteries to operate the sash. VS skylights utilize a manually -driven rotary operator. Sizes, general dimensions and fastener requirements for deck mount units are described in Tahics I (FS) and 2 (VSNSENSS) and Figures 1 (FS), 2 (FS), 3 (VSNSENSS) and 4 (VSNSENSS) of this report. Certified energy, light and comfort factors (U, SHGC, VT and CR) shall conform to 2015 IRC Section N1101.10.3, 2012 IRC Section N1101.12.3 and 2015 and 2012 IECC Sections C303.1.3 and R303.1.3 (NFRC 100 and 200) and NFRC 500 for all sizes and are shown in Table 3 of this report. 3.3 DESIGN AND INSTALLATION Based on the positive and negative performance grade ratings listed in Tables I_ and of this report, the product size(s) shall be selected that have performance grades in excess of the design pressures that are applicable to the unit's final location. Uplift wind ratings recognized in this report are based on attachment to a lumber substrate exhibiting a minimum specific gravity of 0.43 as defined in Table 11.3.2A of the ANSI/AF&PA NDS with full nail engagement. Installation on wood substrates with a specific gravity less than 0.43 may result in a lower wind uplift rating. 4.0 CURB MOUNT GLASS -GLAZED UNIT SKYLIGHTS 4.1 USES: VELUX' FCM, VCE, VCM, and VCS No Leak SkylightsTm are unit skylights complying with IBC Section 2405.5 that provide natural light and views into the interior of building spaces. The skylights are intended for use on building roofs sloped from 0° (0:12 slope) from the horizontal plane to 60' from the horizontal plane. Each unit is designed to attach to a site -built curb that is constructed from nominal 2-inch (50.8 mm) by 4-inch (102 mm) wood members of sufficient strength to transfer the skylight loads to the framing members. Skylights may be attached to other curb materials of equal or greater size and strength. VCE, VCM and VCS skylights provide natural ventilation via an operable top -hinged sash supported by an integral frame assembly. FCM units are fixed. Glass is continuously supported on all four sides using a roll -formed aluminum frame (assembled with ASA corner keys) to resist uplift wind loads. Curb mount products are particularly well -suited for replacement of existing curb -mounted skylights. 4.2 DESCRIPTION 4.2.1 Insulating Glass Units: Insulating glass units (IGU) used in curb mount glass -glazed unit skylights complying with Section 10.2 of AAMAIWDMA/CSA 101/I.S.2/A440- 11 comply with ASTM E2190 and are constructed from either a 1/8 inch (3.18 mm) or 5/32 inch (3.97 mm) thick clear Low-E3-coated tempered glass lite outboard, a sheet of 7/32 inch (5.56 mm) thick laminated glass lite inboard and a stainless -steel spacer system for an overall thickness of 5/8 inch (15.9 mm). The Laminated glass lite inboard is comprised of two sheets of 3/32 inch (2.4 mm) thick heat strengthened glass that are each permanently bonded to either a 0.030 or 0.090 inch (0.8 or 2.3 mm) thick polyvinyl butyral (PVB) clear interlaycr. When increased thermal performance is desired, an additional Low-E .coating is applied on the interior glass surface of the IGU. The space between glass lites is filled with 95 percent argon gas. Page 2 of 19 Originally Issued: 10/08/2010 Revised: 09/12/2017 4.2.2 Assembly Details: Condensation and air leakage control is accomplished through the use of baffled weep holes in the pane support gasketing. VELUX FCM, VCE, VCM and VCS skylights consist of several integrated components. One panel of aluminum - framed flat IGU is bottom -mounted onto a rigid polyvinyl chloride (PVC) sash for the VCE, VCM and VCS skylights and is directly mounted in the field onto the site -built curb for the FCM skylight. Hot -applied primary sealant is bonded to the aluminum frame prior to IGU placement, for all three models. Top -hinged sashes on the VCE, VCM and VCS Skylights are fastened to and supported on a similar rigid PVC frame with extruded aluminum counter flashing. This frame is supported in the field by the site -built curb. VELUX FCM skylight utilizes a dual-durometer thermoplastic elastomer (TPE) inner frame gasket that is T-nailed to the glazing frame to lock the IGU in place for sealant curing and handling stability. VCE, VCM and VCS counter flashing is a mitered and welded frame that is used to fasten the entire unit to the site -built curb. All VELUX VCE, VCM and VCS skylights are equipped with insect screens. VCE and VCS skylights employ an electric motor -driven sash operator with radio frequency remote control and have exterior sensors to automatically trigger the operator to close an open sash when rain droplets are present. VCS skylights use solar powered batteries to operate the sash. VCM skylights utilize a manually -driven rotary operator. Sizes, general dimensions and fastener requirements for curb mount units are described in Tables 4 (FCM) and 5 (VCENCMNCS) and Figures 5 (FCM), 6 (VCENCMNCS) and 7 (VCENCMNCS) of this report. Certified energy, light and comfort factors (U, SHGC, VT and CR) for all sizes shall conform to 2015 IRC Section N1101.10.3, 2012 IRC Section N1101.12.3 and 2015 and 2012 IECC Sections C303.1.3 and R303.1.3 (NFRC 100 and 200) and NFRC 500. The ratings are shown in Table 6 of this report. 4.3 DESIGN AND INSTALLATION Based on the positive and negative performance grade ratings listed in -rgh1e,: 4 and 5 of this report, the product size(s) shall be selected that have performance grades in excess of the design pressures that are applicable to the unit's final location. Uplift wind ratings recognized in this report are based on attachment of the curb to a lumber substrate exhibiting a minimum specific gravity of 0.43 as defined in Table 11.3.2A of the ANSI/AF&PA NDS with full nail engagement. Installation on lumber substrates with a specific gravity less than 0.43 may result in a lower wind uplift rating. 5.0 TUBULAR DAYLIGHTING DEVICES 5.1 USES: VELUX SUN TUNNELT°^ TCR, TGR, TGF, TMR, and TMF Residential Skylights, and TCC, TGC and TMC Commercial Skylights are tubular daylighting Valid Through: 09/30/2018 devices (TDD) complying with 2015 IBC Sections 1709.6 and 2405 and 2012 IBC Section 1710.6 and 2405 that collect and conduct natural light from above into building spaces. All series listed are intended for use on building roofs sloped up to 60 degrees from the horizontal plane. The TGF, TGR, TMF and TMR series are designed for slopes of 3 unit's vertical in 12 units from the horizontal plane (25-percent) and above. 5.2 DESCRIPTION 5.2.1 VELUX SUN TUNNELTM TCC, TCR, TGC, TGF, TGR, TMC, TMF and TMR Skylights are series of tubular daylighting devices, each consisting of an exterior steel roof flashing capped with a clear molded acrylic copolymer (Plexiglas"' HFI-7) exterior dome unit, and an interior diffuser assembly consists of extruded aluminum and a single acrylic diffuser joined by a rigid metallic telescopic or flexible tunnel tube with a reflective interior surface. The Dome materials comply as Class CC2 light - transmitting plastics in accordance with criteria prescribed in IBC Section 2606.4 and the standard referenced in IBC Section 2405.5. 5.2.2 ASSEMBLY DETAILS TGC, TGF and TGR standard series consist of a low profile flashing that mounts to the roof deck, projects 4 inches (102 mm) upward and aligns the dome base to be parallel to the roof deck. TMC, TMF and TMR standard series consist of a pitched flashing that mounts to the roof deck and projects 9 inches (229 mm) upward on the downward roof slope and allows the dome base to be inclined relative to the adjacent roof. TCC and TCR standard series consist of a square flashing designed for mounting on a site -built curb of any material or height. Optional tile roof flashing kits are available for all the series. Each SUN TUNNEL series is available in up to three model sizes — 10, 14 and 22 inches (254, 355 and 559 mm) defined by the tunnel diameter - depending on the series selected. Domes for all available in 10 and 14 inches (254 and 355 mm) models and the 22-inch (559 mm) TGF are the traditional "shallow dish" shape proven on residential buildings. Domes for all other 22-inch (559 mm) models use a new light -directing assembly that is significantly taller and houses the SunCurve Daylight Directing device more appropriate for larger, nonresidential spaces. An optional 12 or 36-inch (305 or 914 mm) long steel turret extender is available for all 14 and 22 inch (355 and 559 mm) flashings if the dome elevation needs to be higher than standard. An optional galvanized steel fire band is available to protect the dome edge where Class A, B or C roof coverings are required. Flexible tunnels are used on the TGF and TMF series, in 14 and 22-inch (355 and 559 mm) sizes. Rigid tunnels with elbow fittings are used for all other standard series. Rigid tunnel joints are easily fastened in the field with Flexi Page 3 of 19 7ES 199 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 LocTM spring clips and sealed with metalized tape, included in standard kits. Where building insulation is installed at the roof level, an optional thermal break section may be inserted into 14 and 22 inch (355 and 559 mm) rigid tunnels in line with that insulation for enhanced energy performance. Assemblies with this option carry numbers ending in EO and have certified thermal ratings. Where needed, a power -operated daylight controller wafer is available as an additional rigid tunnel option. Diffuser Assemblies: Three bottom designs are available: • Type THC, for use where a rigid ceiling will support the diffusers and lower tunnel. This assembly holds up to four light diffusing acrylic glazing layers, with two being standard. Two additional layers are recommended when the attic insulation is at the ceiling, and are available as part of the `residential" Energy Kit. That kit also includes a heat gain shield that is attached to the underside of the shallow dome. [10, 14 and 22 (254, 355 and 559 mm)]. • Type TOC, used where no ceiling exists. This assembly caps the tunnel end using one diffusing acrylic layer. [14 and 22 inch (355 and 559 mm) only]. • Type TTC, used where there is a non -rigid ceiling and a square diffuser is required. This assembly includes a transition section to fit the round tunnel bottom and support a 24 in square panel of diffusing acrylic_ [14 and 22 inch {355 and 559 nun) only]. Each diffuser type utilizes one of three available lower glazing finishes — frosted, prismatic, or Fresnel-patterned. The THC diffuser option with a frosted finish is the standard for TCR, TGF, TGR, TMF and TMR series assemblies. The base kits for these series are shipped complete, with all parts used in the tested specimens. There is no complete "Base Kit" available for the TCC, TGC and TMC series. These products are packaged in subassembly cartons that shall be ordered together and field assembled to create assemblies qualified by the tested ones. The following are the assembly model numbers covered herein: Page 4 of 19 VES EVALUATION REPORT Numbe 19 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 Residential Models Shipped as Complete Kits TGF 014 0000 TGR O10 0000 TMR 010 0000 TCR 014 OOOOUS TGF 014 OOOOEO TGR 010 OOOOEO TMF 014 0000 TMR 010 OOOOEO TCR 014 OOOOUSEO TGF 022 0000 TGR 014 0000 TMF 014 OOOOEO TMR 014 0000 TGF 022 OOOOEO TGR 014 OOOOEO TMR 014 OOOOEO �TCC Commercial Models Shipped as Separate Subassemblies _ 014 --- TGC 014 .. TMC 014— TCC 022 ... TGC 022 ... �! OOOOTH ... OOOOTH ... OOOOTH ... 3000TH ... 3000TH ... OOOOTHEO OOOOTHEO — OOOOTHEO .,. 3000THEO ... 3000THEO ... OOOOTO ... OOOOTO ... OOOOTO ... 3000TO ... 3000TO OOOOTOEO OOOOTOEO OOOOTOEO 3000TOEO 3000TOEO ... OOOOTT ... OOOOTT ... OOOOTT ... 3000TT ... 3000TT ...000OTTEO ...000OTTEO OOOOTTEO ...3000TTEO 3000TTEO ... 0002TH ... 0002TH ... 0002TH ... 3002TH ... 3002TH 0002THEO ... 0002THEO 0002THEO ... 3002THEO ... 3002THEO ... 0002TO ... 0002TO ... 0002TO ... 3002TO ... 3002TO ... 0002TO EO ... 0002TO EO ... 0002TO EO ... 3002TO EO ... 3002TO EO ... 0002TT ... 0002TT ... 0002TT ... 3002TT ... 3002TT 0002TTE0 .0002TTEO 0002TTE0 ...3002TTEO 3002TTEO ... 0003TH ... 0003TH ... 0003TH ... 3003TH ... 3003TH 0003THEO ... 0003THEO ... 0003THEO 3003THEO . , . 3003THEO ... 0003TO ... 0003TO ... 0003TO ... 3003TO ... 3003TO 0003TOEO 0003TOEO 0003TOEO 3003TOEO 3003TOEO ... 0003TT ... 0003TT ... 0003TT 3003TT ... 3003TT 0003TTEO ... 0003TTEO ... 0003TTEO 3003TTE0 ... 3003TTEO Sizes, general dimensions and fastener requirements for tubular daylighting devices are described in Tables 7 and 8 and Figures 8 (TGF/TMF), (TGR/TMR), and (TCR/TCC/TGC/TMC) of this report. Certified energy and comfort factors (U and SHGC) applicable to many listed models for all sizes shall conform to Sections N1101.10.3 and N1101.12.3 of the 2015 and 2012 IRC, respectively, and 2015 and 2012 IECC Sections C303.1.3 and R303.1.3 are shown in Table 9 of this report Page 5 of 19 Originally Issued: 10/08/2010 Revised: 09/1212017 5.3 DESIGN AND INSTALLATION Based on the positive and negative performance grade ratings listed in Tables 7 and 8 of this report, identify the product size(s) that have performance grades in excess of the design pressures that are applicable to the unit's final location. Uplift wind ratings recognized in this report are based on attachment to a wood substrate exhibiting a minimum specific gravity of 0.43 as defined in Table 11.3.2A of the ANSI/AF&PA NDS full nail engagement. Installation on wood substrate with a specific gravity less than 0.43 result in a lower wind uplift rating. Suspension wires maybe required in some projects such as where there is no rigid ceiling to offer support at the diffuser level. A kit is available for this purpose. 6.0 IDENTIFICATION 6.1 VELUX FS, VS, VSE, VSS FCM, VCE, VCM and VCS skylights covered by this report shall be identified with permanent labeling that includes the following information: • Manufacturer's name, address, full model number and traceability code number. 6.2 VELUX FS, VS, VSE, VSS, FCM, VCE, VCM and VCS skylights covered by this report shall be identified with temporary pane labeling that includes the following information: • Manufacturer's name and address, tested model size and designation, glass type and thickness, NFRC- certified ratings and WDMA or other approved labeling agency. • Primary and secondary designators as required by the AAMA/WDMA/CSA 101/I.S.2/A440 specification including but not limited to the positive and negative performance grade ratings. • IAPMO ES or UES Marks of Conformity and evaluation report number (ER-199) 6.3 VELUX SUN TUNNELTM TCC, TCR, TGC, TGF, TGR, TMC, TMF, and TMR skylights covered by this report shall be identified with permanent labeling that includes the following information: • Risk of Fall and ID label with the manufacturer's name, address and a traceability code number placed at the bottom center of the flashing during factory subassembly. • The full assembly model number and any applicable NFRC ID number is printed on an adhesive label that will need to be applied to a specified interior surface at installation .199 Valid Through: 09/30/2018 6.4 VELUX SUN TUNNELTM TCC, TCR, TGC, TGF, TGR, TMC, TMF, and TMR skylights covered by this report shall be identified with temporary labeling that includes the following information: • Manufacturer's name and address, tested model size and designation, dome type, NFRC-certified ratings and WDMA or other approved labeling agencies. • Primary and secondary designators as required by the AAMA/WDMA/CSA 101/I.S.2/A440 specification including but not limited to the positive and negative performance grade ratings. • LkPMO ES or UES Marks of Conformity and evaluation report number (ER-199). IAPMO UJs ES or IAPMO ER-199 8.0 SUBSTANTIATING DATA Reports of component and assembly testing and evaluation in accordance with AAMA/WDMA/CSA 101/I.S.2/A440-11, NFRC 100, 200 and 500. 8.0 CONTACT INFORMATION VELUX AMERICA, LLC. P.O. Box 5001 Greenwood, South Carolina 29648-5001 (864)941-4828 www.veluxusa.com Page 6 of 19 UEs Originally Issued: 10/08/2010 9.0 STATEMENT OF RECOGNITION Revised: 09/12/2017 This evaluation report describes the results of research carried out by IAPMO Uniform Evaluation Service on Verco America, LLC's Deck Mount Glass -Glazed Unit Skylights, Curb Mount Glass -Glazed Unit Skylights and Tubular Daylighting Devices to assess conformance to the codes shown in Section 1.0 of this report, and serves as documentation of the product certification. Brian Gerber, P.E., S.E. Vice President, Technical Operations Uniform Evaluation Service 1'1e'�Aoz Richard Beck, PE, CBO, MCP Vice President, Uniform Evaluation Service GP Russ Chan y CEO, The IAPMO Group For additional information about this evaluation report please visit ss a-w.unifnrm-es.or L or email us at i is fi ifa uniform-cs.ar= 199 Valid Through: 09/30/2018 Page 7 of 19 uES Originally Issued: 10/08/2010 Revised: 09/12/2017 199 Valid Through: 09/30/2018 Table 1 - VELUX FS Skylights - Glass Weight = 5 psf Skylight Description NAFS Performance Grades Other NAFS Designators Size Code Unit size0) (inches) inches Download PGpos ( ) Uplift PGNe ( s) Primary Maximum Air Z Leakage(2) Max. Pressure with No Water Penetration(Z) A06 14-% x 45-3/4 +16,758 Pa (+350 psf) -5,040 Pa (-105 psf) SKG-PG105 775x1397' (31 x55') 0.1 L/s/m2 (<0.01 cfm/ft2) 720 Pa (psf) sfl C01 21 x 26-7/8 C04 21 x 37-7/8 C06 21 x 45-3/4 C08 21 x 54-7/16 D26 22 '/z x 22-15/16 D06 22 1/ x 45-3/4 M02 30-1/16 x 30 M04 30-1/16 x 37-7/8 M06 30-1 /16 x 45-3/4 M08 30-1/16 x 54-7/16 S01 44-'/a x 26-7/8 +7,670 Pa (+160 psf) -3,360 Pa (-70 psf) SKG-PG70 1137x1175 45x46 0.1 L/s/M2 (0.01 cfm/ftZ) 720 Pa (15 psf) S06 44-1/4 x 45-3/4 01 Hough opening dimensions M Based on tested size indicated in Primary Designator Table 2 - VELUX VS, VSE and VSS Skylights - Glass Weight = 5 psf Skylight Description NAFS Performance Grades Other NAFS Designators Size Code Unit size0) inches Downward PGpos ( ) Uplift PGNeg Primary Maximum Air Leakage (2) Max. Pressure with No Water Penetration (2) C01 21 x 26-7/8 +19,152 Pa (+440 psf) -5,040 Pa (-105 psf) SKG-PG105 775x1390" (30x55*) 0.1 L/s/m2 (<0.01 cfm/ft2) 720 Pa (15 psf) C04 21 x 37=7/8 C06 21 x 45-3/4 C08 21 x 54-7/16 M04 30-1 /16 x 37-7/8 M06 30-1 /16 x 45-3/4 M08 1 30-1/16 x 54-7/16 S01 44-1/4 x 26-7/8 +17,715 Pa ( +370 psf) -3,120 Pa (-65 psf) SKG-PG65 1197x1238 (47x49) 0.1 L/s/m2 (0.02 cfm/ft2 ) 720 Pa (15 psf) tSO6 44-1 /4 x 45-3/4 � Rough opening dimensions "z Based on tested size indicated in Primary Designator Table 3: Deck Mount Skylights - Energy, Light and Comfort Model/Glazing U-Factor Btulftz/"F/hr Solar Heat Gain Coefficient SHGC Visible Transmittance (VT) Condensation Resistance CR FS ...04 0.44 0.26 0.60 0.60 50 52 FS ...06 0.42 0.26 FS ...08 0.44 J0.25 0.44 50 FS ...99 94 0.38 0.26 0.60 42 Vs ... 04 0.42 1 0.23 0.53 53 VS ... 06 0.40 0.23 0.52 55 VS ... 08 0.42 0.22 0.39 r 0.52 53 44 VS ... 99 94 0.37 0.23 1. U-factors and Solar Heat Gain Coefficient, Visible Transmittance have been determined in accordance with NFRC 100 and NFRC 200, respectively by an accredited, independent laboratory, and labeled and certified by the manufacturer. 2. Condensation Resistance have been determined in accordance with NFRC 500 by an accredited, independent laboratory, and labeled and certified by the manufacturer. Page 8 of 19 UES Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 Figure 1 — VELUX FS Skylight (Horizontal Section View) ,:1 C. Figure 2 — VELUX FS Skylight (Vertical Section View) Page 9 of 19 qT ' ' .- 199 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 Figure 3 — VELUX VS/VSE/VSS Skylight (Horizontal Section View) I' i f Ii K� '.. _(� 1 . 41 �• r_...I- i+ Figure 4 — VELUX VS/VSE/VSS Skylight Page 10 of 19 UE �?�t y y ! REPORT Originally Issued: 10/08/2010 Revised: 09/12/2017 199 Valid Through: 09/30/2018 Table 4 — VELUX FCM Skylights — Glass Weight = 5 psf Skylight Description NAFS Performance Grades Other NAFS Designators Size Code Unit size0) (inches) Download (PGPOS) Uplift PGNe p ( e) Primary Prima Maximum Air Leakage(2) Max. Pressure with No Water Penetration(2) 1430 17-1/2 x 33-1/2 +11,990 Pa (+250 psf) -5,760 Pa (-120 psf) SKG-PG120 1308 x 1308 (51x51*) 0.1 L/s/m2 (0.02 cfm/ftz) 720 Pa (15 psf) 720 Pa (15 psf) 1446 17-1/2 x 49-1/2 2222 25-1 /2 x 25-1 /2 2230 25-1 /2 x 33-1 /2 2234 25-1/2 x 37-1/2 2246 25-1/2 x 49-1/2 3030 33-1 /2 x 33-1 /2 3046 33-1/2 x 49-1/2 3434 37-1/2 x 37-1/2 4646 49-1/2 x 49-1/2 2270 25-1 /2 x 73-1 /2 + 9,590 Pa (+200 psf) -4,800 Pa (-100 psf) 9KG-PG100 660 x1854* (26 x 73*) 0.1 L/s/mz (0.01 cfm/ftz) Table 5 — VELUX VCE, ­VCM and VCS Skylights — Glass Weight = 5 psf Skylight Description FNAFS Performance Other NAFS Designators Grades Size Unit size0) Downward Uplift Primary Maximum Air Leakage(2) Max. Pressure with No Water Code _(inches PGPos PGNeq Penetration 2 2222 25-1/2 x 25- r11 1/2 25-1 /2 x 37- F 1/2 25-1/2 x 49- 2246 1/2 33-1/2 x 33- 3030 1/2 +11,052 Pa (+230 psf) 33-1/2 x 49- 3046 1/2 3434 37-1/2 x 37- 1/2 4646 49-1 /2 x 49- 1/2 (1) Outside Curb dimensions -2,560 Pa (-45 psf) SKG- PG45 0.1 L/s/mz 1305 x 1305 (0.02 cfm/ftz) (51 x51 *) (2) Based on tested size indicated in Primary Designator Page 11 of 19 720 Pa (15 psf) UEs , ► '�`� 199 TM Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 Table 6: Curb Mount Skylights - Energy, Light and Comfort Model/Glazing U-Factor (Btu/ft2rF/hr)-_ FCM ...04 0.48 Solar Heat Gain Coefficient (SHGC)_ 0.27 0.27 Visible Condensation Transmittance VT Resistance CR 0.63 50 _ FCM ...06 0.46 0.62 51 FCM ...08 0.48 0.26 0.46 50 FCM ...99 94 0.43 0.25 0.57 42 VC ... 04 0.53 0.24 0.55 E 58 VC ... 06 0.50 0.24 0.54 59 VC ... 08 0.53 0.23 0.40 11 58 VC ... 99 94 0.48 0.22 0.49 49 1. U-factors and Solar Heat Gain Cent, Visible Transmittance shall be determined in accordance with NFRC 100 and NFRC 200, respectively and by an accredited, independent laboratory, and labeled and certified by the manufacturer- 2. Condensation Resistance shall be determined in accordance with NFRC 500 and by an accredited, independent laboratory, and labeled and certified by the manufacturer I i , ♦ —dW A 7,1" Prcd-1 dim--.J n : Pnnn dii— -.inn- Thrnn- slim cn �ior �. <73 �NI G'y 1,76 34 99G 9�3.8 y.I 46- •13C,7 I2_'ri.5 r 01 �C 1010,5 1348 1�95 5 07 F �, urr dime -Finn Fein? dinlenSir,n I I r I I I II I I I I I I I I - I II , I I I + I •+ I i I + I I II I I r r II I I �Thl�oal olm?I��ion I II r I II I l II I Figure 5 — VELUX FCM Skylight Horizontal Section View (Typical for Vertical Section View) Page 12 of 19 (oUIFO;,IEIII 50IFFUI_1- TD1 F'APT/i_UPOPICG. A Cu rcr Frame F or-s rr'.rt• inner `raTle cja l<e Caner Bey +I _ Pane se-7ani SCHEDULE. FASTFNEF 1_M PAR-r':"MPOP -- IN��nd `�rrF`VJ ­11II.. UEs EVALUATION REPORT 199 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 Figure 6 — VELUX VCM/VCEIVCS Skylight Horizontal Section View Sizc 22 I'S'dc framr. 532.5 Throat FILM Pcnc 675.5 504.5 629 30 Y 735.5 378.5 980 708 832 933 5 837 809.5 4 G 1.1 1 286 1 t j 4,5 1238 5 FLIv1 I nsidc Fr_ i i I � ll l Threal 1' �I Page 13 of 19 -- •� ` lj — _ L —" �I 1 PART ✓'TEM A SCHEDULE PAPT/COMPONENT Pan, B Oular Framc - Pnng SPgcar ,D (Nrl own) D Inner frame Corgc:r hey Coun ler flashing �a_h Frame G i Cgeh sled mg bloc! U!lG gr.d,cl F::a„ j r 'u,,.n p�,seglgnl E-1111,11, 7UEs EVALUATION REPORT Originally Issued: 10/08/2010 Revised: 09/12/2017 199 Valid Through: 09/30/2018 Figure 7 — VELUX VCMNCENCS Skylight Vertical Section View Site + In,ide frame Thront FLM Fare 22 5-2.5 6755 504_5 629 30 735.5 878.5 708 832 34 8�•� 98G 809.5 933.5 46 1142 1286 1114-5 12--8 5 - � I l f •' "J ili lill ' � i inll�l I �, r e A v 0 a V• r Page 14 of 19 PART SCHEDULE 1111i PART/CMPONENT N Counl al Ilashinn 0 Lwlatiw :1 - Incolakn (Eldcrn• dghl) Screen relainer P (D.U.rn only) 0 •none r-kel f, ur, nr,iY;rinr j u ::..— II H=!= Threaded In!& r�yimf ren heed Rf � r H.�•lur. 3�evr Inwr: L ::�•:w �� 'r Hcad Scrw # Note decigrmlc,• the Ilem 3N[ Shown R-s % (m,,-Nnr S rexl &Rem Y Bro_; In srl) rre -d In R m'S (lecntcr) Originally Issued: 10/08/2010 Revised: 09/12/2017 PE Valid Through: 09/30/2018 Table 7 — VELUX SUN TUNNELT" Skylights (Residential) Skylight Description NAFS Performance Grades Other NAFS Designators Model Code Unit sized) (inches) Download (PGpos) Uplift (PGNeg) Primary Maximum Air Leakage(2) Max. Pressure with No Water Penetration(2) TGF 014 14 +14,364 Pa (+300 psf) -6 064 Pa (-125 psf) TDDCC-PG125 Size Tested 559 min (22") 0.2 L/s/mz (0.04 cfm/ftz) 720 Pa (15 psf) TGF 022 22 TMF 014 14 TGR 010 10 TGR 014 14 TMR 010 10 TMR 014 14 TCR 014 14 +14,364 Pa +300 ( psf) -7,980 Pa 165 ( psf) TDDCC-PG 1650.5 Size Tested 356 m) in14" L/s/mz (0.09 cfm/ftz) 720 Pa (15 psf) Table 8 — VELUX SUN TUNNELTI Skylights (Commercial) Skylight Description NAFS Performance Grades Other NAFS Designators Model Unit size0) Download Uplift Primary Maximum Air Max. Pressure with No (inches) (� ) , ( PGPos ) ( PGNe e) Leakage(z) Water Penetration(z) TCC 014 14 +14,364 Pa (+300 psf) -7,023 Pa (-145 psf) TDDOClTDDCC- PG145 Size Tested 1.4 L/s/mz (0.28 cfm/ftz) 720 Pa (15 psf) TGC 014 TMC 014 356 mm (14") TCC 022 TDDOClTDDCC- 22 +14,364 Pa (+300 psf) -6,224 Pa (-130 psf) PG130 Size Tested 1.5 L/s/mz (0.30 cfm/ftz) 720 Pa (15 psf) TGC 022 559 mm (22") (i) Nominal tunnel size (z) Based on tested size indicated in Primary Designator Page 15 of 19 UEs '199 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 Table 9: SUN TUNNELT"9 Skylights - Energy and Comfort Assembly Names U-Factor Solar Heat Gain Coefficient Btu/ft2/°F/hr SHGC 0.21 0.25 TGF/TMF all 0.50 TGR/TMR ...EO w/ Energy Kit 0.38 TCR ...EO w/ Energy Kit 0.38 0.25 TCC/TGC/TMC 014 ...TOEO (w/ 0.55 0.28 Energy Kit) Insulation at Roof TCC 014 ...THEO (w/ Energy Kit) 0.38 0.25 Insulation at Ceilin4 TCC 022 ...TTEO (w/ Energy Kit) 0.43 0,22 Insulation at Roof TGC 022 ...TTEO (w/ Energy Kit) 0.41 0.26 Insulation at Roof 1. U-factors and Solar Heat Gain Coefficient shall be determined in accordance with NFRC 100 and NFRC 200, respectively and by an accredited, independent laboratory, and labeled and certified by the manufacturer- T1-J F C E.1 v 1: 4, "tim s10e ��, i _. )i�aw H i PI to (part of Energy Kit) - -11, F-'ti (Optional) Resfoontlal £nkr• . I Port Schedule e Done Pivot/Inter-ncdlota Ring Conplote C Pitch Flashing (TIC/TMP) n Top Collar C Lo. profile Floshing tTGr; TGP) F-1 Scre. r Fle- Tubing (TGF%TMF) a DCP- Klt,'Celling Ring Complete N Diffuser Gosl•.et [ Clear Diffusor Heot Gain Shield Plate Figure 8 — VELUX SUN TUNNELT" (TGF/TMF) Skylight Page 16 of 19 CUE EVALUATION REPORT Nut TFA Originally Issued: 10/08/2010 Revised: 09/12/2017 T/1 n (Optional) —it ''hiPl d part of Energv Kit 199 Valid Through: 09/30/2018 Port Schedule A Done a Pivot/Intermediate Ring Complete c Pitched Floshng (TW/TMR) a LoA ProfAe Flashing (TGF/TGP) E Top Cdlor EA Scree. F Elbor (TGR/TMR) G Rigid Tube (TGR/TMR) u Pull Clip (TGR/TMR) DCP. Klt/Celgng Ring Conplete Clear Dirfuser k MIFFuser Gasket L Meat Gain Sheld Plate Figure 9 — VELUX SUN TUNNELTM (TGR/TMR) Skylight Page 17 of 19 qIr +F 199 Originally Issued: 10/08/2010 Revised: 09/12/2017 Valid Through: 09/30/2018 H i0 TCC 021 Tcc 014 in �j,an Ceiling pilfu5er Q3 1 �I f J '\ n K L Tu6it� k Ci6aus TMC 014 TCt /TGC.`]NC_ CcmmerSiol Fieehno TTC 1)14.'022 Trnrs�itlgr issaxi Launmercial C1lifusef< I 0 ,t Port Schedule i Mgld Tu6,g t Open Celing Uf Fuser INF(us Tr.n yTipn �. Cars W D;Ffu r Fro .4' to 22' Pound to Pound ocbptoi c [."",g Ping Conplete frin Ring ❑ho. I E TG' 022 Hph P,00, D— 1 Llpnt Nrr<IL+R �.k. Dw .} C C✓b GI.tHrp [fCC� PltdKd Flo t*V ,TNC� Tw cal.- . Pt.at/IRltr.ed.it RFq Copltlt i Rdd Tout Clba. FYo. rnh SHdd Rol. f 1�TGC C114 THC C,14 /02- Hard Ceiling Ditfu2jLr H - D) Figure 10 — VELUX SUN TUNNELTM (TCC/TCR/TGC/TMC) Skylight (Note — TCR is similar to TCC 014 with THC Diffuser) Page 18 of 19 Originally Issued: 10/08/2010 Revised: 09/12/2017 CALIFORNIA SUPPLEMENT VELUX AMERICA, LLC • VELUX FS, VS, VSE and VSS Deck Mount Glass - Glazed Unit Skylight • VELUX FCM, VCE, VCS and VCM Curb Mount Glass -Glazed Unit Skylights VELUX SUN TUNNEL TM Skylights (TCC, TCR, TGC, TGF, TGR, TMC, TMF and TMR) (plastic - glazed tubular daylighting devices) CSI Section: 08 62 00 Unit Skylights 1.0 Compliance with the following codes • 2016 California Building Code (CBC) 2.0 Requirements: All information in ER-199, dated 09/12/2017 corresponding to compliance under the International Building Code (IBC) also apply to compliance under the CBC. Additional requirements for compliance with the CBC are provided in Section 3.0 of this supplement 3.0 Additional Requirements: 3.1 Compliance for Materials Used Reports of material testing and evaluation in accordance with Clauses 10 and 11 of AAMA/WDMA/CSA 101/LS.2/A440- 11 and -08 comply with the applicable requirements of CBC Chapter 7A and Section 1505.1 for fire resistance and Section 2405 and Chapter 26 for light transmitting plastic components. Acrylic Domes are in compliance with CBC Sections 2606 and 2610. Table 1 —Glass Area, Nominal Frame Lap and 199 Valid Through: 09/30/2018 3.2 Glazing Requirements For those applications subject to the requirements of the Division of the State Architect -Structural Safety/Community Colleges (DSA-SS/CC) or the Office of Statewide Planning and Development (OSHPD 1 & 4), Table 1 of this supplement provides information to verify compliance with the additional provisions of Section 2403.2.1 and Table 2403.2.1 of the 2016 California Building Code. 4.0 Contact Information VELUX America, LLC. P.O. Box 5001 Greenwood, South Carolina 29648-5001 (864)941-4828 www.veluxusa.com Glass Edge Clearance Largest Size Nominal Design Values - mm (in.) Skylight Model Glass Area Frame Lap Glass Edge Clearance (ftz) Sides Bottom Top Sides Bottom Top FS 13.29 23 (7/8) 23 (7/8) 22 (7/8) 3 (1/8) 7 4 (1/8) VS / VSE / VSS 12.02 12 (1/2) 14 (1/2) 14 (1/2) 4.5 (3/16) 3 (1/8) FCM 16.51 18 (3/4) 18 (3/4) 18 (3/4) 31 (1-1/4) 31 (1-1/4) 31 (1-1/4) VCE / _VC M / VCS 16.51 18 (3/4) 18 (3/4) F18 (3/4) 31 (1-1/4) 31 (1-1/4) Page 19 of 19