0206-215 (RC) Revision 1 Title 24{ f TITLE 24 Energy Conservation Standards Compliance Report (Revised Calculation) POINT HAPPY BUILDING 2 HIGHWAY 111 & WASHINGTON LA QUI" -;TA (Building Shell Only) March 22, 2002 o Job Number: 20.120C Preparers For: PREST VUKSIC ARCHITECTS, INC. 74020 ALLESSANDRO SUITE C PALM DESERT, CA 92260 760-779-5393 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE 'T I 1 D'G BY Catherine M. Madlin, Certified Energy Analyst Post Office Box 1443 Palm Springs, CA 92263 760-322-5004 / 323-3644 (fax) E-mail: GMadlin@aol.com , J Madlin 's enterprises Catherine M. Madlin, Certified Energy Analyst Y 760-322-5004 / 323-3644 (fax) ®®®®®® Title 24 Energy Conservation Standards Compliance Report This proposed project has bee' reviewed for compliance with the 2001 State of California Energy Conservation Standar�s, Title 24, by Madlin's Enterprises. The building design described in this compliance portfolio is in conformance with the standards as outlined in the attached compliance forms and documentation. Date: March 22, 2002 Job Number: 201200 Prepared For: PREST VUKSIC ARCHITECTS, INC. Project Name: POINT HAPPY BUILDING 2 Project Location: HIGHWAY 111 & WASHINGTON, LA QUINTA Method of Compliance: ENERGYPRO CERTIFIED COMPUTER PROGRAM Certified Energy Analyst Catherine M. Madln NR 98-90-544 r r R 98-90.144 r CADEC Califomia Associodon of Building Energy Conwlronis v Post Office Box 1443 ® Palm Springs, Ca 92263 v Madlin s enterpfises Catherine M. Madlin, Certified Energy Analyst v 760-322-5004 / 323-3644 (fax) ®V ®®®® V Note To Plan Checker -C,;' .i + %L, Date: March 22, 2002 Job Number: 201200 Prepared For:. PREST VUKSIC ARCHITECTS, INC. Project Name: POINT HAPPY BUILDING 2 The attached revised compliance calculations reflects building envelope Please contact me if you have any questions. Cathy Madlin Y,, v Post Office Box 1443 v Palm Springs, Ca 92263 v U•b60 U=.660 <1I U•fbb0 , U=bb0 11.. 'i_a Uz b0 i FkGC = OSL (Tu p Uz b0 a ini s enterpfises Catherine M. Ma&in, Cer(Pd Energy Analyst v 760-322-5004 323-3644 (fax) Title 24 Compliance Forms PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of PERF -1 PROJECT NAME Point Happy Buildings 2 This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE 3/20/02 PROJECT ADDRESS..<;:;:,,:.. BUILDING CONDITIONED FLOOR AREA 5,035 sy.Ft. CLIMATE ZONE 15 Highway 111 at Washington St. -La Quinta NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION [:] ALTERATION EXISTING + ADDITION for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this `Bwlding PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Permit If Prest Vuksic Architects 760-779-5393 ❑ F] 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section DOCUMENTATION AUTHORTELEPHONEY Mad lin's Enter rises 322-5004 � Checked by/Date;sIR 'entAgencyUse because it pertains to a structure or type of work described as exempt pusuant to Business and Professions (760) �'Ertfo�ce ,a GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and DATE OF PLANS DOCUMENTATION AUTHOR BUILDING CONDITIONED FLOOR AREA 5,035 sy.Ft. CLIMATE ZONE 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION [:] ALTERATION EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Building using the performance compliance approach. DOCUMENTATION AUTHOR SIGN E DATE Catherine M. Madlin00, The Principal Designers hereby certify that the proposed building design represented in the construction documents Ad m Belled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. ❑ F] 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. ❑ ❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNA RE LIC. NO. DATE Prest Vuksic Architects LIGHTING COMPLIANCE Indicate location on plans of Note Block for Man tory Measure Lighting Compliance Not In The Scope Of Require orms t)mtttal PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Mechanical Compliance Not In the Scope Of Required Forms ThiS Submittal PRINCIPAL MECHANICAL DESIGNER - NAME I SIGNATUREILIC. NO. I DATE jEnergyPro 3.1 By EnergySoft User Number: 1069 Job Number 20120C Page:1 of 6 [PERFORMANCE -CERTIFICATE.OF COMPLIANCE Part 2 of 3 PERF -1 Point Ha DATE Buildings 2 3/20/02 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/s ft- r ENERGY COMPONENT Standard Design Proposed Design Compliance Margin Qropoaed Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water , Lighting Receptacle Process - TOTALS: 1.61 2.14 -0.54ic�r I �g ' s 1ggjg. k4 3 q H � 71.80 72.57 -0.77 '29.97 27.59 2.38 0.00 0.00 0.00 0.00 0.00 0.00 0.000.00 0.00 50.05 50.05 0.00 = �aaiedB , 15.91 15.91 0.00, 0.00 0.00 0.00°�`° 169.33- 168.26 1.07 BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (west) 270 deg Conditioned Floor Area 5,035 sgft. Unconditioned Floor Area o sqft. Conditioned Footprint Area 4,975 sgft. 1 1 1 Orientation Front Elevation (West) Left EleVatlOR (North) Rear Elevation. (East) Right Elevation (South)l Total Roof Gross Area sqft. sqft. sqft. sqft. sqft. sqft. Glazing Area Glazing sqft. sqft. sqft. sqft. sqft. sqft. Ratio 1,238 517 41.7% 915 134 14.9% 1,274 250 19.6% 936 60 6.5% 4,364 961 4,975 0.0% Standard Proposed Lighting Power Density 1.700 W/sgft. 0.000 w/sgft. Prescriptive Env. Heat Loss 1,036 988 Prescriptive Env. Heat Gain 123,435 123,226 Remarks: Building Envelope Revisions Run Initiation Time: 03/20/02 1.0:57:11 Run Code: 1016650631 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20120C Page:2 of 6 PERFORMANCE' CERTIFICATE OF COMPLIANCE Part3 of 3 PERF -1 PROJECT NAME DATE Point HapU Buildings 2 3/20/02 ZONE INFORMATION Floor Inst. Ctrl: `- Tailored System Name Area LPD Zone Name Occupancy Type (sgft.) (W/sf)1 Credits � _LPD i* Ver1t . (W/sf)? Loads ; AC ZONE 1 Retail Comp Bldg Retail/Wholesale 5,035 0.000 MEN>ir5 .$.a+.�.�;'``&'� .:tea 4 i ..l..w �N %S.A1:C�' M", Tn'... .., .� 3F�$'r+�,�Z�.S,�".F''R,�44�'F��X;i,.�"�a�Ai f'��i`�'i..y •., r Y NO 'R115 ayr x'Ee z'xst' r k'k4..r' tr. Ks,: �g x 4e ic..h..:Yr,...s,, `�'"M.,?'&g� ��.w4.��'`,t^'Y GAJ,`•`• ".�i: ... ' - 1:. zsya^�T.•.e t} �!� r kix"'A`i.y`}°...L sr'r„ a"�4"M�-eo�y",� $tiE'GY'?S�°rb +�w�i�..11�� �>e.�.t��:t�S".w .;`&'.tun: Hp�_�.'�' �. &. ...:i'2�rik�i•�k�i 1.1 '� �i "�� spliWW;'t 'fiY�� Notes: 1; See LTG -1 (items marked with asterisk, see. LTG -2 by others) 2. See LTG -3 3. See LTG -4 nte�ms above requ{re speaal documentabon'` EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST Tho Inral —6-1A --- r—s—r--•�• •-•••+••••�•• •� ...� •.����� �r�..,•,�� .a utw cnecicnst. 1 nese items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adeauacv of the iustifiratinnand may r i.M a I ..H ii...n —.; a•...:__ .— ­___.._ _ _ ____._ _ _ .. .. _ _ _ I ne exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp _ Run Initiation Time: 03/20/02 10:57:11 Run Code: 1016650631 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20120C Page:3 of 6 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME Point Happy Buildings 2 OPAQUE SURFACES -- --- ----_..... ...... .,................. Area U -Fac. Act. Azm. SHGC U ­L­L=runn. Glazing Type Location / Comments DATE 3/20/02 Surface Framing Act. # Type Type Area U -Fac. Azm. Tilt Solar Gains y/N Form 3 Reference Location / Comments 1 Wall IWood 781 0.059 0 90 X R-21 Wall .21.2x6.16 Retail 2 Wall Wood 1,000 0.059 90 1 90 X R-21 Wall .21.2x6.16 Retail 3 Door None 24 0.581 90 90 X Hollow Metal Door Retail 4 Wall Wood 855 0.059 180 5 Door None 21 0.581 180 90 90 X X R-21 Wall .21.2x6.16) Hollow Metal Door Retail Retail 6 Wall Wood 721 0.059 270 90 X R721 Wall .21.2x6.16 Retail 7 Roof Wood 4,975 0.028 0 0 X11 I R-38 Roof R.38.2x14.16 Retail Double Mtl LowE Fixed & Drs Retail 5 Window 88 0.660 90 0.52 Double MU LowE Fixed & Drs Retail 6 Window 60 0.660 90 0.52 I Retail 7 Window 60 0.660 1 90 i Double MU LowE Fixed & Drs Retail 8 Window 4 0.660-1 90 0.52 Double MU LowE Fixed & Drs Retail 9 Window 60 0.660 180 I Double MU LowE Fixed & Drs Retail 10 Window 60 0.660 270 0.52 Double Mtl LowE Fixed & Drs etail FENESTRATION SURFACES 28 0.660 270 0.52 Site Assembled Glazing "��^ ��^ " '.."Y '"_ 1 uu,uuu squ or GFA and >= 1 u,000 sqtt vertical glazing then NFRC Certification is required. Follow, NFRC 100 -SR Pronerlures and submif nicor i - 1 r # Type -- --- ----_..... ...... .,................. Area U -Fac. Act. Azm. SHGC U ­L­L=runn. Glazing Type Location / Comments 1 Window 30 0.660 0 0.52 Double MU LowE Fixed & Drs Retail 2 IWindow 30 0.660 0 0.52 Double MU LowE Fixed & Drs Retail 3 lWindow 74 0.660 0 0.52 Double MU LowE Fixed & Drs Retail 4 Window 38 0.660 90 0.52 Double Mtl LowE Fixed & Drs Retail 5 Window 88 0.660 90 0.52 Double MU LowE Fixed & Drs Retail 6 Window 60 0.660 90 0.52 Double Mtl LowE Fixed & Drs Retail 7 Window 60 0.660 1 90 0.52 Double MU LowE Fixed & Drs Retail 8 Window 4 0.660-1 90 0.52 Double MU LowE Fixed & Drs Retail 9 Window 60 0.660 180 0.52 Double MU LowE Fixed & Drs Retail 10 Window 60 0.660 270 0.52 Double Mtl LowE Fixed & Drs etail 11 Window 28 0.660 270 0.52 Double MU LowE Fixed & Drs 3etail 12 Window 16 0.660 270 0.52 Double Mtl LowE Fixed & Drs letail 13 Window 48 0.760 270 0.52 Double MU LowE Fixed & Drs letail 14 Window 16 1 0.660 1 270 0.52 Double MU LowE Fixed & Drs letail 15 lWindow 600.660 270 0.52 Double MU LowE Fixed & Drs etail EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. Hot. Dist. Len. H t. 1 None 0.76 7.0 4.3 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 2 None 0.76 7.0 4.3 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 3 None 0.76 8.2 9.0 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 4 None 0.76 7.5 5.0 1.0 0.1 0.1 0.1 0.1 1.5 0 0.1 1.5 0 5 None 0.76 8.8 10.0 1.5 0.1 0.5 0.5 0.5 1.5 0 0.5 1.5 0 6 None 0.76 7.5 8.0 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 7 None 0.76 7.5 8.0 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 8 None 0.76 1.5 3.0 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 9 None 0.76 8.2 7.3 1.0 0.1 0.5 0.5 0.5 1.0 0 0.5 1.0 0 10 None 0.76 7.5 8.0 1.0 0.1 0.1 0.1 0.1 1.0 0 0.1 1.0 0 11 None 0.76 3.0 10.0 1.5 0.1 0.1 0.1 0.1 1.5 0 0.1 1.5 0 12 None 0.76 8.0 2.0 1.5 2.0 0.1 0.1 0.1 1.5 0 0.1 1.5 0 13 None 0.76 8.0 6.0 1.5 3.0 2.0 2.0 2.0 1.5 0 2.0 1.5 0 14 None 0.76 8.0 2.0 1.5 2.0 0.1 0.1 0.1 1.5 0 0.1 1.5 0 15 one _ 0.76 7.5 8.0 1.0 0.1 0.1 0.1 0.1 1.0 0 _ 0.1 1.0 0 Run Initiation Time: 03/20/02 10:57:11 Run Code: 1016650631 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20120C Page:4 of 6 ENVELOPE COMPLIANCE SUMMARY Performance ENV -1 PROJECT NAME DATE Point Happy Buildings 2 _ 3/20/02 OPAQUE SURFACES ' Solar i Surface Framing Act. Gains # Type Type jArea U -Fac. Azm. Tilt y/N Form 3 Reference Location / Comments I I i I FENESTRATION SURFACES Site Assembled GlazingF-I Check box if Building is>= 100,000 sqft of CFA and >= 10,000 sqft vertical glazing then NFRC Certification is required. Follow NFRC 100 -SB PrOCPrb Ira,, and suhmit NFRr: 1 nbal r.artifi-t. P - # Type AreaIU-Fac. Act. Azm. SHGC Glazing Type Location / Comments 16 Window 48 1 0.760 270 0.52 1 Double Mtl LowE Fixed & Drs Retail 17 Window 12 1 0.660 270 0.52 1 Double Mtl LowE Fixed & Drs Retail 18 Window 66 1 0.660 270 0.52 1 Double Mtl LowE Fixed & Drs Retail 19 Window 66 1 0.660 270 0.52 Double Mtl LowE Fixed & Drs Retail 20 Window 21 1 0.660 1 270 0.52 Double Mtl LowE Fixed & Drs Retail 21 Window 13 1 0.660 270 0.52 Double Mtl LowE Fixed & Drs Retail 22 Window 48 0.760 270 0.52 Double Mtl LowE Fixed & Drs Retail 23 Window 13 0.660 270 0.52 Double Mtl LowE Fixed & Drs Retail EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Len. HCIt. LEAREA Dist. Len. H t. Right Fin Dist. Len. H t. 16 None 0.76 8.0 6.0 1.0 2.0 0.1 0.1 0.1 1.0 0 0.1 1.0 0 17 None 0.76 2.0 6.0 1.0 0.1 0.1 0.1 0.1 1.0 0 0.1 1.0 0 18 None 0.76 9.5 7.0 0.5 0.1 0.5 0.5 0.1 0.5 0 0.1 0.5 0 19 None 0.76 9.5 7.0 0.5 0.1 0.5 0.5 0.1 0.5 0 0.1 0.5 0 20 None 0.76 1.9 9.5 1.0 0.1 0.1 0.1 0.1 1.0 0 0.1 1.0 0 21 None 0.76 8.0 1.8 1.0 1.0 0.1 0.0 0.1 1.0 0 0.1 0.0 0 22 None 0.76 8.0 6.0 1.0 2.0 2.0 2.0 2.0 1.0 0 2.0 1.0 0 23 None 0.76 8.0 1.8 1.0 1.0 0.1 0.0 0.1 1.0 0 0.1 0.0 0 Run Initiation Time: 03/20/02 10:57:11 Run Code: 1016650631 EnergyPro 3.1 By EnergySoft User Number: 1069 Job Number: 20120C Page:5 of 6 i ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME DATE Point Happy Buildings 2 3/20/02 DESCRIPTION Designer Enforcement LTJ §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X§ 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. FX]§ 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. 0 .§116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). FRI § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. FX -1 §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. EnergyPio 3.1 By EnergySoft User Number: 1069 Job Number: 20120C Page:6 of 6