2022 Maintenance Log10/12/22, 12:35 PM
Print Request
Request: 52562 Entered on: 07/21/2022 10:47 AM By: Kristopher Gunterson
Customer Information
Name: Kristopher Gunterson
Address:
Phone: (760) 636-8170
Alt. Phone:
Email: kgunterson@laquintaca.gov
Request Classification
Topic: Traffic Signals - 1082
Status: Closed
Assigned to: Kristopher Gunterson
Problem Location: JEFFERSON ST & AVENUE 48, La Quinta
i�
Request type: Maintenance
Priority: Normal
Entered Via: Internal
JEFFERSON ST & LAVENUE 48, La Quinta
•.11114VIA j r' %
V/II Ii .
. 441 1.7 •
Original Date:
Time of Day:
Reoccurs Every:
Intersection: Jefferson and Avenue 48
Description
Install new ATC Cabinet and configure intersection defined by the traffic signal modification form.
Engineering firm to created Delta revision on the as built plans.
Perform LEVEL 3 Preventative Maintenance
- PERFORMED LEVEL 3 MAINTENANCE
- CLEANED/VACCUMED ALL PULL BOXES
- WORK DONE
Date Expect Closed: 10/31/2022
Reason Closed
Date Closed: 10/12/2022 12:34 PM By: Kristopher Gunterson
Enter Field Notes Below
Notes:
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6393693&type=0 1/2
10/12/22, 12:35 PM
Print Request
Notes Taken By:
Date:
Follow-up Information
#1: 10/10/2022 08:45 AM - Message sent to manager by Armando Cabrera Jr
(WAITING ON NEW CABINET TO ARRIVE.
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6393693&type=0 2/2
Preventative Maintenance Level 3
Intersection
Work Order #
[JEFFERSON AND AVENUE 48
52562
Check flash operation of police panel.
I
Date
Check flash operation of maintenance panel. Loosen and secure all field landings.
Upgrade flash transfer relays, load switch flashers, and load switches. Qty of Relays
Vacuum and dust Electrical service cabinet. Test voltage drop from service to cabinet breaker.
Clean and re -seal cabinet base with industrial sealant.
IL
Test cabinet power supply 12 Volts DC
t F t(d I
24 Volts DC
5_5 . J
Qty of Flasher
Qty of Load Switches
Cabinet Voltage NC
l s 1
Clean & Lubricate all cabinet locks Test cooling fan operation
Inspect dust filter
Rc pt.tof
Vacuum and inspect cabinet for damage, graffiti or function. Dust and clean shelves and components.
Inspect Controller event log. Note any repeating issues
Test Battery Back Up System
Battery Volts End
I4)yya 1
Test Run Time
Comprehensive check of vehicle detection for all phases. Adjust or repair detector files as necessary.
Test Results
Inspect all approaching phases for roadway or sidewalk damage. Photograph each phase approach for digital log.
Check all approaches for sight distance issues with foliage. Correct as necessary.
Inspect all signal poles for damage, missing hand hole covers or graffiti
Inspect and retro-reflective test all traffic control signs for all approaches. Replace based on test results.
EIC
Inspect all phase indications for operation and brightness.
Replace as necessary
RB GB RA
I 1 1a I I>ef I II
Check operation of all Pedestrian Push Buttons, signs and frameworks Upgrade all buttons to Polara Bulldog type.
Buttons Frameworks Sign
1=9=! I I V
Test Emergency Vehicle Preemption
Northbound
IRAs
Southbound
R�11�
Monitor traffic flow and operational smoothness. Notify Traffic Engineer of any issues.
Field note or recommended repairs
Eastbound Westbound
fig
YA
giA
Pedestal Voltage A/C
Battery Date
GA
PED
r;1
t D'.4-rn l t t r Cut -IS
NtPs-g
Preventative Maintenance Level 1
Work Order #
Date Intersection
Vacuum and inspect all cabinets for damage, graffiti or function.
Inspect cooling fan operation.
q9
Inspect Controller Event Log Note any repeating issues.
q1
Record BBS Log Number of Events Run Time
0P
Dust and clean cabinet shelves and components. Dust Filter
Clean
Comprehensive Check of vehicle detection for all phases. Adjust or repair detector files as necessary.
Inspect all approaching phases for roadway or sidewalk damage
Inspect all signal poles for damage, missing hand hole covers or graffiti.
Inspect all phases indications for operation and brightness. Replace as necessary.
Check operation of Pedestrian Push Buttons.
Inspect all traffic control signs for all approaches.
��Monitor traffic flow and operational smoothness Notify Traffic Engineer of any issues.
7"
Notes or recommended repairs.
RB-
YB-
GB-
RA-
YA-
GA-
RAPS-
LAPS-
AIRFLITER- a
FLASH RELAY -
CONTROLLER EVENTS- t0
2/24/22, 7:14 AM Print Request
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6126569&type=0 1/2
Request: 50737 Entered on: 02/17/2022 2:02 PM By: Kristopher Gunterson
Customer Information
Name:Kristopher Gunterson Phone:(760) 636-8170
Address:Alt. Phone:
,Email:kgunterson@laquintaca.gov
Request Classification
Topic:Traffic Signals - 1082 Request type:Maintenance
Status:Closed Priority:Normal
Assigned to:Kristopher Gunterson Entered Via:Internal
Problem Location:JEFFERSON ST & AVENUE 48, La Quinta
Original Date:
Time of Day:
Reoccurs Every:
Intersection:Jefferson and Avenue 48
Description
Perform LEVEL1 Preventative Maintenance
Reason Closed
- PERFORMED LEVEL 1 MAINTENANCE
- WORK DONE
Date Expect Closed: 03/11/2022
Date Closed: 02/24/2022 07:13 AM By: Kristopher Gunterson
Enter Field Notes Below
Notes:
2/24/22, 7:14 AM Print Request
https://user.govoutreach.com/laquintaca/printrequest.php?curid=6126569&type=0 2/2
Notes Taken By: Date: