BCOM2021-0109Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
Description: PANERA BREAD / 4,3555F RESTAURANT/VB/A-2-OCC/122-OL/SPRINK
Type: BUILDING COMMERCIAL Subtype: STORES/CUSTOMER Status: ISSUED
(WEB) SERVICE
Applied: 11/11/2021 ECON
Approved: 4/13/2022 JFU
Issued: 7/15/2022 AHI
Finaled:
Expired: 9/17/2023 JFU
Parcel No: 643080051 Site Address: 78902 HIGHWAY 111 LA QUINTA,CA 92253
Subdivision: PM 25865 Block: Lot: 12
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $323,576.50 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 4,355SF RESTAURANT BUILDING WITH DRIVE-THRU AND OUTDOOR DINING AREA. VB/A-2-OCC/5122-OL/FULLY SPRINKLED [PANERA
BREAD] THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, BUILDING SIGNAGE, SITE LIGHTING, CARPORTS, EVCS OR TRASH
ENCLOSURES. CVMSHCP DOES NOT APPLY BASED ON EXISTING LAND USE, NO TUMF ASSESSMENT DUE TO CREDIT FOR BUILDING
PREVIOUSLY EXISTING ON THIS PARCEL. NO DIF ASSESSED PER DIF COORDINATOR DETERMINATION. 2019 CALIFORNIA BUILDING
CODES.
Process Summary
93
153
Applied to Approved
Approved to Issued
ADDITIONAL SITES
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
E-MAIL
AJ ORTEGA
8/10/2022
8/10/2022
EMAILED APPLICANT AND CONTRACTOR (nina@rsi-
group.com
Cc: 'Chuck Mickelson' <CMickelson@cmcorp.co>) REGARDING
REVISION 1 - TRUSS SUBMITTAL CONDITIONS OF APPROVAL.
E-MAIL
JAKE FUSON
12/20/2021
12/20/2021
NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT
CORRECTION LIST VIA EMAIL.
E-MAIL
JAKE FUSON
3/7/2022
3/7/2022
NOTIFIED APPLICANT OF 2ND REVIEW RESULT. FIRE
APPROVAL AND ADMINISTRATIVE ITEMS REQUIRED IN
ORDER TO ISSUE PERMIT.
E-MAIL
JAKE FUSON
4/13/2022
4/13/2022
NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND
PERMIT IS READY TO ISSUE PENDING RESOLUTION OF ALL
CONDITIONS FOR ISSUANCE (SEE CONDITIONS TAB).
RESUBMITTAL
AJ ORTEGA
2/18/2022
2/18/2022
ATTACHMENTS VERIFIED, REVIEWS CREATED.
Printed: Wednesday, March 29, 2023 4:06:50 PM
1 of 22
CRI f'SYSTEMS
Permit Details
City of La Quints
PERMIT NUMBER
BCOM2021-0109
RESUBMITTAL
JAKE FUSON
3/25/2022
3/25/2022
CONDITIONS
CONDITION
TYPE
CONTACT
DATE
ADDED
DATE
REQUIRED
DATE
SATISFIED
STATUS
REMARKS
NOTES
READY TO ISSUE
CHECKLIST
JAKE FUSON
3/7/2022
7/12/2022
7/12/2022
COMPLETE
THE FOLLOWING ARE REQUIRED PRIOR TO
PERMIT ISSUANCE:
-DEMO PERMIT FOR DEMOLISHED BUILDING ON
THIS PARCEL
-GRANT DEED/OWENERSHIP INFO
-WASTE MANAGEMENT PLAN
-HEALTH DEPT APPROVAL
-CVWD APPROVAL
-CONTRACTOR
-SCHOOL FEE PAYMENT
UPDATE: ALL ITEMS RECEIVED EXCEPT SCHOOL
FEE PAYMENT.
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
RSI GROUP
3187 Airway Avenue,
Suite A
Costa Mesa
CA
92626
(760)413-1997
nina@rsi-group.com
CONTRACTOR
CONSTRUCT & MAINTAIN CORP
27075 CABOT RD STE
#114
LAGUNA HILLS
CA
92653
(760)413-1997
cmickelson@cmcorp.co
OWNER
ONE ELEVEN LA QUINTA
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY AMOUNT
PAID
PAID DATE RECEIPT # CHECK #
METHOD
PAID BY
CLTD
BY
RE -INSPECTION FEE
101-0000-42400
0
$83.37
$83.37
9/8/22
R72044
09269G
CREDIT
CARD
MARK AGUILERA
AMA
Total Paid for ADMINISTRATIVE:
$83.37
$83.37
Printed: Wednesday, March 29, 2023 4:06:50 PM
2 of 22
CRWSYSTEMS
Permit Details
City of La Quinta
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID
CLTD
BY
ART IN PUBLIC PLACES
COMMERCIAL
270-0000-43201
0
$1,617.88
$1,617.88
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for ART IN PUBLIC PLACES - AIPP: $1,617.88 $1,617.88
HOURLY CHARGE CITY
BUILDING STAFF
101-0000-42600
1
$167.00
$167.00
8/24/22
WEB12878
712545101
CREDIT
817124
ECON
HOURLY CHARGE
ESGIL CIVIL ENGINEER
101-0000-42600
2
$210.00
$210.00
8/24/22
WEB12878
712545101
CREDIT
817124
ECON
Total Paid for BLDG CITY STAFF - PER HOUR: $377.00 $377.00
BSAS SB1473 FEE
101-0000-20306
0
$13.00
$13.00
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for BUILDING STANDARDS ADMINISTRATION $13.00 $13.00
BSA:
NON-RESIDENTIAL, EA
ADDITIONAL 2,000SF
101-0000-42403
0
$83.36
$83.36
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
NON-RESIDENTIAL, EA
ADDITIONAL 2,000SF PC
101-0000-42600
0
$22.24
$22.24
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
NON-RESIDENTIAL,
FIRST 2,000SF
101-0000-42403
0
$125.05
$125.05
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
NON-RESIDENTIAL,
FIRST 2,000SF PC
101-0000-42600
0
$96.70
$96.70
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for ELECTRICAL - NEW CONSTRUCTION 2021: $327.35 $327.35
FIRE NEW
COMMERCIAL
101-0000-42421
0
$417.00
$417.00
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
FIRE NEW
COMMERCIAL PC
101-0000-42420
0
$500.00
$500.00
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for FIRE FEES: $917.00 $917.00
CONDENSER/COMPRES
SOR
101-0000-42402
0
$333.44
$333.44
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Printed: Wednesday, March 29, 2023 4:06:50 PM
3 of 22
CRWSYSTE S
Permit Details
City of La Quinta
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID
CLTD
BY
CONDENSER/COMPRES
SOR PC
101-0000-42600
0
$222.32
$222.32
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
EXHAUST HOOD
101-0000-42402
0
$41.67
$41.67
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
EXHAUST HOOD PC
101-0000-42600
0
$16.68
$16.68
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
FURNACE
101-0000-42402
0
$166.72
$166.72
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
FURNACE PC
101-0000-42600
0
$111.16
$111.16
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
OTHER MECHANICAL
EQUIPMENT
101-0000-42402
0
$208.40
$208.40
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
OTHER MECHANICAL
EQUIPMENT PC
101-0000-42600
0
$208.40
$208.40
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
VENT FAN
101-0000-42402
0
$55.56
$55.56
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
VENT FAN PC
101-0000-42600
0
$22.24
$22.24
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for MECHANICAL 2021: $1,386.59 $1,386.59
NEW CONSTRUCTION
PERMIT 2021
101-0000-42400
0
$2,616.11
$2,616.11
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for NEW CONSTRUCTION PERMIT 2021: $2,616.11 $2,616.11
NEW CONSTRUCTION
PLAN CHECK 2021
101-0000-42600
0
$1,724.74
$1,724.74
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for NEW CONSTRUCTION PLAN CHECK 2021: $1,724.74 $1,724.74
BACKFLOW DEVICE
101-0000-42401
0
$13.89
$13.89
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
BACKFLOW DEVICE PC
101-0000-42600
0
$5.56
$5.56
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
BUILDING SEWER
101-0000-42401
0
$27.79
$27.79
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
BUILDING SEWER PC
101-0000-42600
0
$19.45
$19.45
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
FIXTURE/TRAP
101-0000-42401
0
$375.03
$375.03
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
FIXTURE/TRAP PC
101-0000-42600
0
$375.03
$375.03
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
GAS SYSTEM, 5+
OUTLETS
101-0000-42401
0
$41.68
$41.68
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Printed: Wednesday, March 29, 2023 4:06:50 PM
4 of 22
CRI f'SYSTEMS
Permit Details
City of La Quinta
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID
CLTD
BY
GAS SYSTEM, 5+
OUTLETS PC
101-0000-42600
0
$27.78
$27.78
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
GREASE INTERCEPTOR
101-0000-42401
0
$41.68
$41.68
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
GREASE INTERCEPTOR
PC
101-0000-42600
0
$13.89
$13.89
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
ROOF DRAIN
101-0000-42401
0
$27.78
$27.78
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
ROOF DRAIN PC
101-0000-42600
0
$27.78
$27.78
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
WATER HEATER/VENT
101-0000-42401
0
$13.89
$13.89
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
WATER HEATER/VENT
PC
101-0000-42600
0
$8.34
$8.34
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
WATER SYSTEM
INST/ALT/REP
101-0000-42401
0
$13.89
$13.89
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
WATER SYSTEM
INST/ALT/REP PC
101-0000-42600
0
$13.89
$13.89
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for PLUMBING 2021: $1,047.35 $1,047.35
RECORDS
MANAGEMENT FEE -
MAJOR
101-0000-42416
0
$21.00
$21.00
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
SMI - COMMERCIAL
101-0000-20308
0
$90.60
$90.60
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $90.60 $90.60
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
0
$5.00
$5.00
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
NEW CONSTRUCTION
NON-RESIDENTIAL
101-0000-42400
0
$322.00
$322.00
7/15/22
R71292
1731586
CHECK
PANERA LLC
AHI
Total Paid for ZONING CLEARANCE - PLANNING PLAN
CHECK: $322.00 $322.00
Printed: Wednesday, March 29, 2023 4:06:50 PM
5 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
INSPECTION
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
SEWER CONNECTION
JFU
9/6/2022
9/6/2022
NOT READY
WORK INCOMPLETE, SUPERINTENDENT
NOTIFIED THAT FURTHER NOT READY
INSPECTION RESULTS WILL REQUIRE FEE
ASSESSMENT IF INSPECTIONS ARE NOT
CANCELLED.
UNDERGROUND PLBG
JFU
9/6/2022
9/6/2022
NOT READY
WORK INCOMPLETE, SUPERINTENDENT
NOTIFIED THAT FURTHER NOT READY
INSPECTION RESULTS WILL REQUIRE FEE
ASSESSMENT IF INSPECTIONS ARE NOT
CANCELLED.
UNDERGROUND PLBG
JFU
9/7/2022
9/7/2022
NOT READY
WORK INCOMPLETE, REINSPECTION FEE
ASSESSED.
UNDERGROUND PLBG
JFU
9/9/2022
9/9/2022
PARTIALLY
APPROVED
DOES NOT INCLUDE GREASE INTERCEPTOR
OR WASTE PIPING OUTSIDE THE BUILDING
FOOTPRINT.
UNDERGROUND ELEC
JFU
9/9/2022
9/9/2022
PARTIALLY
APPROVED
4" CONDUITS FROM SWITCH GEAR TO
SUBPANEL.
UNDERGROUND ELEC
JFU
9/22/2022
9/22/2022
APPROVED
REMAINING BRANCH CIRCUITS
THROUGHOUT BUILDING.
SLAB
JFU
10/6/2022
10/6/2022
DISAPDROVE
SEE FOOTINGS INSPECTION NOTES.
Printed: Wednesday, March 29, 2023 4:06:50 PM
6 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
FOOTINGS
JFU
10/6/2022
10/6/2022 DISAPPROVE
D
-COLUMN REINFORCEMENT AT HSS
COLUMNS STILL IN PROGRESS
-2ND MAT REQUIRED AT F2 & F3 PAD
FOOTINGS (TOP & BOTTOM)
-CORNER BARS MISSING AT SEVERAL
LOCATIONS
-INCORRECT BOLTS PLACED AT HDU14
HARDWARE, SEE SCHEDULE ON 2/5006
-PROVIDE 3" CLEARANCE FROM
REINFORCEMENT TO EARTH
-PROVIDE FORM CERTIFICATION FROM
SURVEYOR/ENGINEER
"'HD19" SPECIFIED AT SHEARWALL 2B
ALONG GRIDLINE "C" HOWEVER THIS PIECE
OF HARDWARE IS NOT IN THE SCHEDULE
2/S006, UNABLE TO DETERMINE CORRECT
BOLT, CONSULT ENGINEER FOR AN ANSWER
-POST BASE HARDWARE MISISNG AT 6x6
POSTS ALONG GRID "A"
-INSTALL ALL ANCHOR BOLTS AT ALL SHEAR
WALLS
-CORRECT REINFORCEMENT AT DEPRESSED
SLAB AREA TO MATCH 8/S301
SLAB
JFU
10/7/2022
10/7/2022
APPROVED
SEE FOOTING INSPECTION NOTES.
FORM CERTIFICATION RECEIVED.
INSPECTION RESULT UPDATED TO
"APPROVED."
FOOTINGS
JFU
10/7/2022
10/7/2022
APPROVED
FORM CERTIFICATION REQUIRED (MUST BE
RE -WORDED TO INCLUDE THE HORIZONTAL
LOCATION OF FORMS).
FORM CERTIFICATION RECEIVED.
INSPECTION RESULT UPDATED TO
"APPROVED."
Printed: Wednesday, March 29, 2023 4:06:50 PM
7 of 22
CRWSYSTE S
Permit Details
City of La Quinta
AIL
FRAMING
JFU
10/17/2022
10/17/2022
NOT READY
INSPECTION REQUESTED FOR STEEL FRAME
INSTALLATION, DIRECTED SUPERINTENDENT
TO CALL IN ONE FRAMING COMBINATION,
ROOF NAIL, OK TO WRAP, ETC WHEN READY.
ROOF NAIL
JFU
10/27/2022
10/27/2022
PARTIALLY
APPROVED
MAIN ROOF ONLY, DOES NOT INCLUDE
TOWERS OR EYEBROW POPOUT ALONG
EAST AND SOUTH FACES OF BUILDING.
ALSO OK TO CONSTRUCT SECOND FURRED
WALL ALONG WEST WALL OF BUILDING BUT
DO NOT APPLY SHEATHING UNTIL
INSPECTED.
OKAY TO WRAP
JFU
11/3/2022
11/3/2022
DISAPPROVE
D
PARTIAL INSPECTION SCHEDULED FOR
SECOND FURRED WALL AT BACK OF
BUILDING ALONG GRIDLINE "A".
CORRECTIONS:
-BLOCKING AND A-35s MISSING PER 5/5-401
AT SHEAR TRANSFER
-AN RFI MUST BE PROVIDED BY THE EOR AS
THE INTERIOR WALL WAS CONSTRUCTED AS
THE STRUCTURAL WALL WITH ALL HOLD
DOWNS, ANCHOR BOLTS, TRUSS BEARING,
ETC. THE OUTER WALL INSPECTED TODAY
DOES NOT MEET THE REQUIREMENTS OF A
BEARING SHEAR WALL, EOR TO ADDRESS.
(SHEAR PANEL INSTALLED ON INTERIOR
WALL AT THIS TIME).
Printed: Wednesday, March 29, 2023 4:06:50 PM
8 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
ROOF NAIL
JFU
12/5/2022
12/5/2022
APPROVED
W/EXCEPTIO
N
INSPECTION SCHEDULED FOR THE
REMAINDER OF THE ROOF NAIL (TOWERS
AND FRONT EYEBROW SECTIONS).
CORRECTIONS:
-H2.5 HARDWARE MISSING AT TOP OF
WALLS AT TOWERS PER 7/5403. SINCE THIS
CONSTRUCTION CAN BE VIEWED FROM
UNDERNEATH, APPROVAL HAS BEEN
GRANTED TO DRY IN ROOFS AND THIS ITEM
CAN BE VERIFIED WITH A LATER INSPECTION
OKAY TO WRAP
JFU
12/5/2022
12/5/2022
DISAPPROVE
D
-PROVIDE STRUCTURAL OBSERVATION
REPORT FROM ENGINEER OF RECORD
-BLOCKING AND A-35s MISSING PER 5/S-401
AT SHEAR TRANSFER
-WALL AT THE REAR OF BUILDING NOT
CONSTRUCTED PER PLAN, SEE 5/5401.
FRAMER STATED AN RFI WOULD BE
PROVIDED FOR THE REVISED LOCATION OF
THE SHEATHING (SHOWN INSTALLED ON
OUTER WALL ON PLANS BUT INSTALLED ON
INNER WALL IN THE FIELD) HOWEVER NO RFI
WAS PROVIDED
-EXTERIOR ELECTRICAL INCOMPLETE,
COMPLETE ALL ELECTRICAL THAT WILL
PENETRATE EXTERIOR OF BUILDING
-INSTALL DRFASTOPPING AT FURRED WALLS
AND SPACES
**DOES NOT INCLUDE INSPECTION OF (4)
TRELLIS COVERS YET OT BE CONSTRUCTED,
SECOND INSPECTION REQUIRED. ENSURE
FLASHING IS INSTALLED BEHIND LEDGERS
PRIOR TO EXTERIOR WALLS BEING DRIED IN
OKAY TO WRAP
JFU
12/13/2022
12/13/2022
APPROVED
APPROVAL IS PENDING STRUCTURAL
OBSERVATION REPORT.
Printed: Wednesday, March 29, 2023 4:06:50 PM
9 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-010�
OKAY TO WRAP
JFU
12/13/2022
12/13/2022
APPROVED
STRUCTURAL OBSERVATION REPORT
RECEIVED, INSPECTION RESULT UPDATED TO
"APPROVED."
ROUGH ELEC
AOR
12/21/2022
12/21/2022
PARTIALLY
APPROVED
EXTERIOR WALLS ONLY.
ROUGH MECH
AOR
12/21/2022
12/21/2022
PARTIALLY
APPROVED
INSPECTION OF SUPPLY AND RETURN DUCTS
FOR VENTILATION EQUIPMENT ONLY, WORK
NOT READY TO BE COVERED BUT NO
CORRECTION ITEMS OBSERVED - RECALL T-
BAR/OVERHEAD INSPECTION WHEN READY
TO COVER AND A SEPARATE ROUGH
MECHANICAL WHEN HOOD DUCTS ARE
READY FOR INSPECTION.
ROUGH PLBG
AOR
12/21/2022
12/21/2022
APPROVED
W/EXCEPTIO
N
RETESTING OF DWV REQUIRED IF METAL
STUD FIXES REQUIRE ALTERATION TO
SYSTEM.
WATER LINE
AOR
12/21/2022
12/21/2022
APPROVED
ROOF DRAIN
AOR
12/21/2022
12/21/2022
APPROVED
GAS LINE/TEST
AOR
12/21/2022
12/21/2022
APPROVED
Printed: Wednesday, March 29, 2023 4:06:50 PM 10 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
ill
FRAMING
AOR
12/21/2022
12/21/2022
PARTIALLY
APPROVED
EXTERIOR WALLS ONLY, DOES NOT INCLUDE
METAL FRAMED WALLS, DROP CEILINGS OR
THE FOUR (4) TRELLIS COVERS AROUND THE
BUILDING EXTERIOR - RECALL T-
BAR/OVERHEAD INSPECTION WHEN READY
TO COVER AND SEPARATE FRAMING
INSPECTIONS WHEN AREAS ARE READY FOR
INSPECTION.
CORRECTION ITEMS OBSERVED WHILE
WALKING EXTERIOR FRAMING AND MEP:
-METAL FRAMING ALTERATIONS REQUIRE
FOR FIX.
-COMPLETE METAL STUD FRAMING PER
SHEET A110, INCLUDING STUD GAUGE FOR
HEIGHT, KICKER SPACING AND
ORIENTATION, AND FASTENERS.
-MANEUVERING CLEARANCE OF 5'
PERPENDICULAR TO INSWING DOOR AT
MENS ROOM REQUIRED.
-RFI REQUIRED FOR MISSING LEDGER PER
DETAIL 3/5401 AT W BEAM ALONG GRID
LINE C.
- RFI REQUIRED FOR MISSING NAILING AND
LENGTH OF LEDGER NOT EXTENDING
BETWEEN VERTICAL WEBS PER DETAIL
2/5403 AT PERPENDICULAR FRAMING
UNDER ROOF TOP DOG HOUSES.
-SDS SCREWS REQUIRED AT LEDGER PER
DETAILS 1, 2, 4, 5 AND 9/5401 AT ALL
EXTERIOR WALLS.
-TRIPLE (3) 2X6 BLOCKING REQUIRED AT
SUPPORT OF WEST TRELLIS STRUCTURE PER
DETAIL 12/S401.
WATER LINE
JFU
1/4/2023
1/4/2023
APPROVED
INSPECTION SCHEDULED FOR UG PVC
WATER SUPPLY FROM METER TO BUILDING.
TRACER WIRE MUST BE BLUE.
Printed: Wednesday, March 29, 2023 4:06:50 PM 11 of 22
CRWSYSTE S
Permit Details
City of La Quinta
WATER LINE
JFU
1/4/2023
1/4/2023
APPROVED
PHOTOS RECEIVED OF BLUE COLORED
TRACER WIRE, INSPECTION RESULT
CHANGED TO "APPROVED."
INSULATION
JFU
1/4/2023
1/4/2023
PARTIALLY
APPROVED
EXTERIOR WALLS ONLY.
FRAMING
DCL
1/11/2023
1/11/2023
PARTIALLY
APPROVED
- ONE SIDE INTERIOR SHEAR FOR EXTERIOR
WALLS AND BACK OF HOUSE, TO WITHIN 2'
OF FLOOR (WEST OF GRIDLINE B) ONLY.
UNDERGROUND PLBG
DCL
1/11/2023
1/11/2023
PARTIALLY
APPROVED
FRAMING
DCL
1/11/2023
1/11/2023
CANCELED
CANCELED INSPECTION RECEIVED CALL
FROM (949)601-1369
SEWER CONNECTION
DCL
1/18/2023
1/18/2023
APPROVED
UNDERGROUND PLBG
DCL
1/18/2023
1/18/2023
PARTIALLY
APPROVED
- FROM TIE-IN AT SEWER TO GREASE
INTERCEPTOR LOCATION. EXCLUDES
GREASE INTERCEPTOR.
GREASE INTERCEPTOR
JFU
2/7/2023
2/7/2023
APPROVED
NOTES:
-CVWD APPROVAL STATES THAT AN
INSPECTION BY THEIR PERSONNEL IS
REQUIRED, CONTRACTOR TO WORK WITH
UTILITY TO ENSURE NECESSARY APPROVALS
ARE OBTAINED PRIOR TO BACKFILL
-GREASE INTERCEPTOR LOCATED PER
UTILITY PLAN SHEET C6.0 (DIFFERS FROM
PLUMBING SITE PLAN)
FRAMING
JFU
2/9/2023
2/9/2023
PARTIALLY
APPROVED
DOES NOT INCLUDE SOFFIT FRAMING AT
MAIN DINING ROOM NOR METAL STUD
WALL DIAGINAL BRACING.
ROUGH ELEC
JFU
2/9/2023
2/9/2023
APPROVED
DOES NOT INCLUDE T-BAR INSTALLATIONS.
ROUGH PLBG
JFU
2/9/2023
2/9/2023
APPROVED
ROUGH MECH
JFU
2/9/2023
2/9/2023
APPROVED
W/EXCEPTIO
N
DID NOT INCLUDE HOODS OR OVERHEAD
INSTALLATIONS AT T-BAR AREAS.
Printed: Wednesday, March 29, 2023 4:06:50 PM
12 of 22
CRI f'SYSTEMS
Permit Details
City of La Quinta
FRAMING
JFU
2/10/2023
2/10/2023
CANCELED
WORK ALREADY INSPECTED AND APPROVED
ON 1/11/2023.
DRYWALL NAIL
JFU
2/13/2023
2/13/2023
PARTIALLY
APPROVED
DOES NOT INCLUDE SOFFIT AT DINING
ROOM. WORK COVERED PRIOR TO
INSPECTION, VERTICAL FRAMING MEMBERS
DON'T MATCH THE DETAILING, ANGLED
BRACES MISSING, ETC.
OVERHEAD ROUGH
PIPING
KHET
2/16/2023
2/16/2023
DISAPPROVE
D
SEE NOTES
Fire Sprinkler Reinspection required.
*Fire Alarm Rough -wire required.
FOOTINGS
JFU
3/1/2023
3/1/2023
CANCELED
CANCELED BY CONTRACTOR (PER DC).
FOOTINGS
JFU
3/2/2023
3/2/2023
CANCELED
INSPECTION REQUESTED FOR CURB AND
GUTTER WHICH IS NOT A REQUIRED
BUILDING DIVISION INSPECTION.
OVERHEAD ROUGH
PIPING
KHET
3/2/2023
3/2/2023
NOT READY
Spk and Fire Alarm
Clearance required
Fire Sprinkler reinspection required.
Fire Alarm Rough wire is still required,
scheduled 3/9.
T-BAR/OVERHEAD
JFU
3/7/2023
3/7/2023
APPROVED
W/EXCEPTIO
N
VERIFY MISSING RIVETS AT MAIN DINING
ROOM AT FINAL INSPECTION.
OVERHEAD ROUGH
PIPING
KHET
3/9/2023
3/9/2023
APPROVED
ROUGH INSP COMPLETED
- OK TO COVER
Printed: Wednesday, March 29, 2023 4:06:50 PM 13 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
ill
TEMP USE OF PERM PWR
JFU
3/15/2023 3/15/2023 DISAPPROVE
D
-PROVIDE PRODUCT LITERATURE FROM
MANUFACTURER CLARIFYING THAT THE
HOLES DRILLED IN THE GROUND BUS ARE
APPROVABLE, OR PROVIDE
RECERTIFICATION BY A TESTING AGENCY
(E.G. UL)
-BOND GAS PIPING AND FIRE SPRINKLER
PIPING IF METAL
-EXPOSE WATER BOND CONNECTION
-PROVIDE LOCKOUT TAGOUT PROCEDURE
AS INTERIOR CPI AND OTHER PANELBOARDS
ARE NOT TOTALLY COMPLETE
-REPLACE DOORS ON EQUIPMENT
-PROVIDE TORQUE CERTIFICATION LETTER
FOR SITE FABRICATED COMPONENTS IN
SWITCH GEAR AND SET UP TO HAVE A SPOT
CHECK FOR VARIOUS TORQUE TESTS ON
NUTS AND BOLTS
GAS LINE/TEST
JFU
3/16/2023
3/16/2023
APPROVED
TEMP USE OF PERM PWR
DCL
3/17/2023
3/20/2023
APPROVED
- DRILLED COMPONENT AT MAIN SWITCH
GEAR REPLACED WITH NEW FACTORY
COMPONENT.- BOND FOR GAS PIPING AND
FIRE SPRINKLER VERIFIED AT BACK OF
HOUSE.- WATER BOND VERIFIED AT BACK OF
HOUSE- TORQUE SPOT VERIFIED AT MAIN
SWITCH GEAR. TORQUE SPECS TO BE
UPLOADED BY CONTRACTOR. -
CONTRACTOR TO SEND LOCK OUT TAG OUT
VIA EMAIL.
FRAMING
JFU
3/21/2023
3/21/2023
APPROVED
EXTERIOR TRELLIS COVERS.
PARENT PROJECTS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE I RE DATEED
STATUS
REMARKS
Printed: Wednesday, March 29, 2023 4:06:50 PM
14of22
CRWSYSTEMS
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
iil
1ST PERMIT TECH —
ETRAKIT (1 DAY)
BUILDING
BUCKET
11/11/2021
11/12/2021
11/16/2021
COMPLETE
REVIEWS PREVIOUSLY CREATED, REVIEW NOW
CLEARED.
1ST BLDG NS —
ETRAKIT (3 WK)
JAKE FUSON
11/11/2021
12/7/2021
12/20/2021
REVISIONS REQUIRED
SEE 1ST REVIEW COMPLETE CORRECTION LIST
(ATTACHED).
1ST FIRE ETRAKIT
(2 WK)
KOHL
HETRICK
11/11/2021
11/29/2021
12/7/2021
REVISIONS REQUIRED
SEE ATTACHMENTS
1ST PLANNING —
ETRAKIT (2 WK)
CARLOS
FLORES
11/11/2021
11/29/2021
11/29/2021
REVISIONS REQUIRED
- PER CONDITIONS OF APPROVAL ON
ENTITLEMENT, APPLICANT SHALL PROVIDE A
TRAFFIC CALMING FEATURE AT THE CROSSWALK
THAT EXTENDS OVER THE DRIVE -THROUGH LANE
- LANDSCAPING TO BE COMPLETED VIA FINAL
LANDSCAPING PLAN. A SEPARATE APPLICATION
SHALL BE SUBMITTED FOR THIS
- STAFF IS SUGGESTING A SIDEWALK TO BE
CONSTRUCTED ON EAST PART OF PROJECT SITE,
GOING NORTH TO SOUTH, CONNECTING TO
EXISTING HIGHWAY 111 SIDEWALK
1ST PUBLIC WORKS
— ETRAKIT (2 WK)
AMY YU
11/11/2021
11/29/2021
11/22/2021
READY FOR APPROVAL
CONDITIONS
PRIOR TO BUILDING PERMIT ISSUANCE, PRECISE
GRADING PLAN, PM-10 CLEARANCE, FINAL
WQMP, PAD CERT, AND GEOTECHNICAL
CERTIFICATION SHOULD BE APPROVED OR
SIGNED OFF BY PUBLIC WORKS
1ST BLDG
COMPLETE (3 WK)
ESGIL
11/12/2021
12/7/2021
12/17/2021
REVISIONS REQUIRED
SEE ATTACHED 1ST REVIEW COMMENTS.
2ND PERMIT TECH —
ETRAKIT (1 DAY)
BUILDING
BUCKET
2/18/2022
2/22/2022
2/18/2022
COMPLETE
ATTACHMENTS VERIFIED, REVIEWS CREATED.
2ND BLDG
COMPLETE (2 WK)
ESGIL
2/18/2022
3/7/2022
3/7/2022
APPROVED
2ND FIRE ETRAKIT
(1 WK)
KOHL
HETRICK
2/18/2022
2/28/2022
3/5/2022
REVISIONS REQUIRED
SEE ATTACHMENTS
2ND PLANNING —
ETRAKIT (1 WK)
CARLOS
FLORES
2/18/2022
2/28/2022
2/28/2022
READY FOR APPROVAL
2ND BLDG NS —
ETRAKIT (2 WK)
JAKE FUSON
2/18/2022
3/7/2022
3/7/2022
REVISIONS REQUIRED
FIRE APPROVAL REQUIRED, THEN PLANS MUST BE
STAMPED BY PRIMARY REVIEWER.
Printed: Wednesday, March 29, 2023 4:06:50 PM
15 of 22
CRWSYSTE S
JILim.
Permit Details PERMIT NUMBER
City of La Quinta
Jt
BCOM2021-0109
3RD FIRE ETRAKIT
(1 WK)
KOHL
HETRICK
3/25/2022
4/1/2022
4/12/2022
APPROVED
COA IN
ATTACHMENTS
3RD BLDG NS —
ETRAKIT (1 WK)
JAKE FUSON
3/25/2022
4/1/2022
4/13/2022
APPROVED
1ST BLDG STR —
ETRAKIT (1 WK)
ESGIL
7/11/2022
7/18/2022
8/10/2022
APPROVED
CONDITIONS
REVISION 1 - TRUSSES
1ST BLDG NS
ETRAKIT (1 WK)
AJ ORTEGA
7/11/2022
7/18/2022
8/10/2022
READY FOR APPROVAL
- CONDITIONS
REVISION 1 TRUSSES
STRUCTURAL CONDITIONS OF APPROVAL
REQUIRED.
2ND BLDG NS —
ETRAKIT (1 DAY)
AJ ORTEGA
8/17/2022
8/18/2022
8/17/2022
APPROVED
REVISION 1- TRUSSES
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
7/12/2022
AARON HICKSON
SCHOOL FEE RECEIPT
2647_001.pdf
0
DOC
3/3/2022
AJ ORTEGA
ESGIL PERCENTAGE OF
FEES CALCULATION
BCOM2021-0109 - ESGIL
PERCENTAGE OF FEES
CALCULATION.pdf
0
DOC
8/17/2022
AJ ORTEGA
REVISION 1 - TRUSS
LAYOUT AND
CALCULATIONS FOR
TOWER (APPROVED)
BCOM2021-0109 -
REVISION 1 - TRUSS
LAYOUT AND
CALCULATIONS FOR
TOWER
(APPROVED).pdf
1
DOC
8/17/2022
Al ORTEGA
REVISION 1 - TRUSS
LAYOUT AND
CALCULATIONS
(APPROVED)
BCOM2021 0109-
REVISION 1 - TRUSS
LAYOUT AND
CALCULATIONS
(APPROVED).pdf
1
DOC
8/17/2022
AJ ORTEGA
LQ-BCOM2021-
0109.REV1.e- Approved
2.pdf
LQ-BCOM2021-
0109.REV1.e- Approved
2.pdf
0
Printed: Wednesday, March 29, 2023 4:06:50 PM
16 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
8/17/2022
AJ ORTEGA
LQ-BCOM2021-
0109.REV1.e-
Approved.pdf
LQ-BCOM2021-
0109.REV1.e-
Approved.pdf
0
DOC
3/17/2023
AJ ORTEGA
LOCK OUT TAG OUT
ACCEPTANCE
BCOM2021-0109 - LOCK
OUT TAG OUT
ACCEPTANCE.pdf
1
DOC
3/17/2023
DUANE CLAYTON
EATON TORQUE
SPECIFICATIONS
BCOM2021-0109 -
TORQUE
SPECIFICATIONS.pdf
1
DOC
11/11/2021
Etrakit Contractor
BUILDING APPLICATION
BCOM2021-0109 -
BUILDING
APPLICATION.pdf
1
DOC
11/11/2021
Etrakit Contractor
1ST SUBMITTAL
GEOTECHNICAL REPORT
BCOM2021-0109 - 1ST
SUBMITTAL
GEOTECHNICAL
REPORT.pdf
0
DOC
11/11/2021
Etrakit Contractor
1ST SUBMITTAL
STRUCTURAL
CALCULATIONS
BCOM2021-0109 - 1ST
SUBMITTAL
STRUCTURAL
CALCULATIONS.pdf
0
DOC
11/11/2021
Etrakit Contractor
1ST SUBMITTAL PLAN
SET
BCOM2021 0109 1ST
SUBMITTAL PLAN
SET.pdf
0
DOC
2/17/2022
Etrakit Contractor
2ND SUBMITTAL
APPLICANT RESPONSES
(BUILDING)
BCOM2021-0109 - 2ND
SUBMITTAL APPLICANT
RESPONSES
(BUILDING).pdf
0
DOC
2/17/2022
Etrakit Contractor
2ND SUBMITTAL
APPLICANT RESPONSES
(FIRE)
BCOM2021-0109 - 2ND
SUBMITTAL APPLICANT
RESPONSES (FIRE).pdf
0
Printed: Wednesday, March 29, 2023 4:06:50 PM
17 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
2/17/2022
Etrakit Contractor
2ND SUBMITTAL
BUILDING CHANGES
BCOM2021-0109 - 2ND
SUBMITTAL BUILDING
CHANGES.pdf
0
DOC
2/17/2022
Etrakit Contractor
2ND SUBMITTAL FIRE
CHANGES
BCOM2021-0109 - 2ND
SUBMITTAL FIRE
CHANGES.pdf
0
DOC
2/17/2022
Etrakit Contractor
2ND SUBMITTAL PLAN
SET
BCOM2021 0109 2ND
SUBMITTAL PLAN
SET.pdf
0
DOC
3/24/2022
Etrakit Contractor
3RD SUBMITTAL FIRE
RESPONSES
Fire Review Response
Letter.pdf
0
DOC
3/24/2022
Etrakit Contractor
3RD SUBMITTAL PLANS
Plans.pdf
0
DOC
7/9/2022
Etrakit Contractor
REVISION 1 1ST
SUBMITTAL TRUSS
LAYOUT AND
CALCULATIONS
BCOM2021-0109 -
REVISION 1 1ST
SUBMITTAL TRUSS
LAYOUT AND
CALCULATIONS.pdf
0
DOC
7/13/2022
Etrakit Contractor
Truss plans for roof
tower.pdf
0
DOC
2/8/2023
Etrakit Contractor
RFI - METAL STUD
BORING
Panera Bread _1254 - La
Quinta , CA_ Response
to RFI _19 (Bore hole -
PLEASE EXPEDITE).pdf
1
DOC
2/9/2023
Etrakit Contractor
RFI - UPDATED DETAIL
3/S401
23-0209 Panera La
Quinta - RFI 16
Response.pdf
1
DOC
2/9/2023
Etrakit Contractor
RFI - SOFFIT FRAMING
UPDATE
1254 La Quinta, CA_RFI
10 Response_22-1208
(1).pdf
1
Printed: Wednesday, March 29, 2023 4:06:50 PM
18 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
401116
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
2/14/2023
Etrakit Contractor
RFI - ACCEPTANCE OF
METAL STUD SOFFIT
ATTACHMENT
Acceptance of Alternate
Condition email 2-13-
23.pdf
1
DOC
2/16/2023
Etrakit Contractor
RFI - REVISED SOFFIT
DETAILING
1254 La Quinta,
CA_Revised Ceiling
Detail_23-0215.pdf
1
DOC
11/23/2021
ESGIL
1ST REVIEW ESGIL
INVOICE
LQ-BCOM2021-0109.e
2.pdf
0
DOC
11/23/2021
ESGIL
1ST REVIEW ESGIL
TRANSMITTAL
LQ-BCOM2021-
0109.e.pdf
0
DOC
3/7/2022
ESGIL
2ND REVIEW
INTERWEST
TRANSMITTAL
LQ-BCOM2021-
0109.RC1.e.pdf
0
DOC
3/7/2022
ESGIL
INTERWEST STAMPED
PLAN
BCOM2021-0109 - 2ND
SUBMITTAL PLAN SET-
Interwest Approved As
Is.pdf
0
DOC
8/10/2022
ESGIL
Approved- BCOM2021-
0109 - REVISION 1 - 1ST
SUBMITTAL TRUSS
LAYOUT AND
CALCULATIONS.pdf
Approved- BCOM2021-
0109 - REVISION 1 - 1ST
SUBMITTAL TRUSS
LAYOUT AND
CALCULATIONS.pdf
0
DOC
8/10/2022
ESGIL
Approved- Truss plans
for roof tower.pdf
Approved- Truss plans
for roof tower.pdf
0
DOC
12/17/2021
JAKE FUSON
1ST REVIEW INTERWEST
COMMENTS (UPDATED
FOR COMPLETE
REVIEW)
BCOM2021 0109 1ST
REVIEW INTERWEST
COMMENTS (UPDATED
FOR COMPLETE
REVIEW).pdf
0
Printed: Wednesday, March 29, 2023 4:06:50 PM
19 of 22
CRWSYSTE S
Permit Details
City of La Quinta
dish PERMIT NUMBER
BCOM2021-0109
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
12/17/2021
JAKE FUSON
1ST REVIEW INTERWEST
INVOICE (UPDATED FOR
COMPLETE REVIEW)
BCOM2021 0109 1ST
REVIEW INTERWEST
INVOICE (UPDATED FOR
COMPLETE REVIEW).pdf
0
DOC
12/20/2021
JAKE FUSON
1ST REVIEW COMPLETE
CORRECTION LIST
BCOM2021 0109 1ST
REVIEW COMPLETE
CORRECTION LIST.pdf
0
DOC
3/10/2022
JAKE FUSON
DETERMINATION OF
DEVELOPMENT IMPACT
FEE ASSESSMENT BY DIF
COORDINATOR
BCOM2021 0109-
DETERMINATION OF
DEVELOPMENT IMPACT
FEE ASSESSMENT BY DIF
COORDINATOR.pdf
1
DOC
4/13/2022
JAKE FUSON
GEOTECHNICAL REPORT
(APPROVED)
BCOM2021 0109-
GEOTECHNICAL REPORT
(APPROVED).pdf
1
DOC
4/13/2022
JAKE FUSON
STRUCTURAL
CALCULATIONS
(APPROVED)
BCOM2021-0109 -
STRUCTURAL
CALCULATIONS
(APPROVED).pdf
1
DOC
4/13/2022
JAKE FUSON
PLANS (APPROVED)
BCOM2021-0109 -
PLANS (APPROVED).pdf
1
DOC
7/12/2022
JAKE FUSON
CONTRACTORS
BUSINESS LICENSE
BCOM2021-0109 -
CONTRACTORS
BUSINESS LICENSE.pdf
1
DOC
7/12/2022
JAKE FUSON
CONTRACTORS
CERTIFICATE OF
INSURANCE
BCOM2021-0109 -
CONTRACTORS
CERTIFICATE OF
INSURANCE.pdf
1
DOC
7/12/2022
JAKE FUSON
CVWD APPROVAL TO
ISSUE
BCOM2021 0109-
CVWD APPROVAL TO
ISSUE.pdf
1
Printed: Wednesday, March 29, 2023 4:06:50 PM
20 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
7/12/2022
JAKE FUSON
DEMO PERMIT RECEIPT
BCOM2021-0109 -
DEMO PERMIT
RECEIPT.pdf
1
DOC
7/12/2022
JAKE FUSON
GRANT DEED
BCOM2021 0109
GRANT DEED.pdf
1
DOC
7/12/2022
JAKE FUSON
HEALTH DEPARTMENT
APPROVAL TO ISSUE
BCOM2021 0109-
HEALTH DEPARTMENT
APPROVAL TO ISSUE.pdf
1
DOC
7/12/2022
JAKE FUSON
WASTE MANAGEMENT
PLAN
BCOM2021 0109-
WASTE MANAGEMENT
PLAN.pdf
1
DOC
10/7/2022
JAKE FUSON
RFI - CLARIFICATION OF
HD19 HOLD DOWN
BOLT
BCOM2021 0109 RFI-
CLARIFICATION OF
HD19 HOLD DOWN
BOLT.pdf
1
DOC
10/7/2022
JAKE FUSON
SPECIAL INSPECTION
REPORT - FOUNDATION
REINFORCEMENT
(10/7/2022)
BCOM2021-0109 -
SPECIAL INSPECTION
REPORT - FOUNDATION
REINFORCEMENT.pdf
1
DOC
10/19/2022
JAKE FUSON
FORM CERTIFICATION
BCOM2021-0109 -
FORM
CERTIFICATION.pdf
1
DOC
12/16/2022
JAKE FUSON
STRUCTURAL
OBSERVATION REPORT
BCOM2021-0109 -
STRUCTURAL
OBSERVATION
REPORT.pdf
1
DOC
12/7/2021
KOHL HETRICK
1ST REVIEW FIRE
CORRECTIONS
BCOM2021-0109 - 1ST
REVIEW - FIRE
CORRECTIONS.pdf
0
DOC
3/5/2022
KOHL HETRICK
2ND REVIEW FIRE
CORRECTIONS
BCOM2021-0109 - 2nd
REVIEW - FIRE
CORRECTIONS.pdf
0
Printed: Wednesday, March 29, 2023 4:06:50 PM
21 of 22
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BCOM2021-0109 ii
ATTACHMENTS
Attachment Type I CREATED
OWNER I
DESCRIPTION
I PATHNAME
SUBDIR I ETRAKIT ENABLED
DOC
4/12/2022
KOHL HETRICK
FIRE CONDITIONS OF
APPROVAL
BCOM2021-0109 - FIRE
CONDITIONS OF
APPROVAL.pdf
1
Printed: Wednesday, March 29, 2023 4:06:50 PM 22 of 22
CRWSYSTEMS