2017 Maintenance LogPrint Request
Request: 26280 Entered on: 03/01/2017 07:27 AM By: Kristopher Gunterson
Page 1 of 2
L.UJ LUMV1 111/V►►►IOL/U11
Name: Kristopher Gunterson Phone: (760) 636-8170
Address: Alt. Phone:
Email: kgunterson@la-quinta.ori
E3 s P, l......:i:....I:.....
►�cyuc�L v►a�anlL.auvn
Topic: Traffic Signals - 1082 Request Maintenance
Status: Open Priority: Normal
Assigned to: Kristopher Gunterson Entered Via: Internal
Problem Location: Miles Ave & Dune Palms Rd
u
Calle Scnrisa
Miles Ave l files Ave Miles Ave
Google Map data 02017 Google
Original Date:
Time of Day:
Reoccurs Every:
Intersection: Dune Palms and Miles
LJCJL. lijuvil
erform level 3 preventative maintenance.
,nnual MMU Test & Swap
Reason I.Ioseu
late Expect Closed: 03/22/2017
Enter Field Notes Below
Notes:
http://user. govoutreach.com/laquintaca/printrequest.php?curid=3103 03 9&type=0 3/1/2017
In
0
Preventative Maintenance Checklist. Level 3
Date" Ltj Intersection `
Vacuum and inspect all cabinets for damage, graffiti or function. (Cooling fan operation)
Check flash operation of police panel and maintenance panel. Exercise relays.
Loosen and tighten all field wire landings.
Vacuum & dust electrical service cabinet.
Record BBS Log Events=
12 Volt 24 Volt
Power Supply t . 6 R VDc Z3 ,1 voc
-est BBS
P / F Begin
Voltage reading at breaker =
Run time=
Endue
Dust and clean cabinet shelves and componants. Replace dust filter.
Dust and clean BBS Cabinet Selves and componants. Replace dust filter.
Pedistal cabinet
�7 (; VAC .�� �t VAc
Run Time
Inspected cabinet documents for cabinet prints, as-builts, and componant operating manuals.
Check for controller telemetry with master and event logs. Note any issues.
Monitor vehicle detection for all phases. Repair any errors.
Inspect all approaching phases for roadway or sidewalk damage.I�C_ �p�fi��t fpr wa
Q r if
�` r
Inspect all signal poles for damage.
Inspect signal LED's for operation and brightness. Replace as necessary.
Inspect all traffic control signs for all approaches.
Monitor traffic flow and operational smoothness. Notify traffic engineer of any issues.
Test EVP function
Distance
NB SB EB
WB
P F P F P/ F
P/ F
Clean and Lubricate all cabinet locks.
Take photos of intersection approaches for annual photo log.
Check all approaches for sight distance obsticles.
Annual MMU test and swap.
Technician &�;i -) L VI Ulf&
Preventa-Live 1,��, intenance Checklist. Level 1
Date 15 11 Intersection
Vacuum and inspect all cabinets for damage, graffiti or function. (Cooling fan operation)
Record BBS Log rv(,nts =lam Run time=�
Dust and clean cabinet sh-'ves find componants. Replace / �ad
ust filter
MInspect control! - r event L- . Pole any repeating issues.
Check for controller teles—'r,,, with master.
Ft Monitor -vehictmm' &c Lip (phases- -Re pairanyerrors.
Inspect all appy,)r-1Jng pl e- !or roadway or sidewalk damage.
Inspect all sigma! -!' ,s for image.
Inspect signal I Lf for ol- •n and brightness. Replace as necessary.
Inspect all traffi- r-ntrol it all approaches.
Ell Monitor traffic ind r ional smoothness. Notify traffic engineer of any issues.
FYI Note if cabinet if d vides :ker panel and/orvideo monitor.
Ter- l „ _ Oxy-
Print Request
Request: 27896 Entered on: 05/19/201712:11 PM By: Jose Villalta
customer rnrormarion
Name: Jose Villalta Phone:
Address: Alt. Phone:
Email:
Request Classification
Topic: Traffic Signals -1082 Request type: Maintenance
Status: Open Priority: Normal
Assigned to: Kristopher Gunterson Entered Via: Internal
Problem Location: Miles Ave & Dune Palms Rd
A
Miles Ave
Original Date:
Time of Day:
Reoccurs Every:
Intersection: Dune Palms and Miles
Description
Perform Level 1 Preventative Maintenance.
Reasun WUZiea
late Expect Closed: 06/30/2017
Enter Field Notes Below
Notes:
Notes Taken By:
Date:
Page 1 of 1
http://user.govoutreach.com/laquintaca/printrequest.php?curid=3230159&type=0 5/24/2017
J
f
J
Preventative Maintenance Checklist. Level 2
Date gi2bf1 Intersection .c. Pte `,,, 5 64, lcS
Vacuum and inspect all cabinets for damage, graffiti or function. (Cooling fan operation)
Vacuum & dust electrical service cabinet. Voltage reading at breaker =
Record BBS Log
Power Supply
Events =
12 Volt
0
24 Volt
(� �S VDC
2311 vac
Run time=
Pedistal
cabinet
2b 1 VAC
1ZC'.S VAC
Test BB
P I YF
Battery Voltage
-226 Begin217VDc Endp
VDC
Run Time
Dust and clean cabinet shelves and componants. Replace /�
Inspect controller event Log. Note any repeating issues.
Check for controller telemetry with master.
Monitor vehicle detection for all phases. Repair any errors.
Inspect all approaching phases for roadway or sidewalk damage.
i
Inspect all signal poles for damage.
Inspect signal LED's for operation and brightness.
1-7( Inspect all traffic control signs for all approaches.
VIMonitor traffic flow and operational smoothness.
"Test EVP function
F
Clean and Lubricate all cabinet locks.
dust filter
Z 5
Replace as necessary. G`' �� �jL- 1 (Do
(S4JS ''s
Notify traffic engineer of any issues. A
FCOB
F
Technician Jb' (, VI (\
B
P F
Print Request Page 1 of 1
Request: 29890 Entered on: 09/21/2017 10:12 AM By: Kristopher Gunterson
Customer Information
Name: Kristopher Gunterson
Address:
Phone: (760) 636-8170
Alt. Phone:
Email: kgunterson@la-quinta.org
Request Classification
Topic: Traffic Signals - 1082
Status: Open
Assigned to: Kristopher Gunterson
Problem Location: Miles Ave & Dune Palms Rd
Request type: Maintenance
Priority: Normal
Entered Via: Internal
Calle Sonrisa
•
Miles Ave
Go gle
Dandelion Dr
Proequities
0
Miles Ave Miles Ave
riap data 02017 Google
Original Date:
Time of Day:
Reoccurs Every:
Intersection: Dune Palms and Miles
Perform Level 2 preventative maintenance.
Description
Date Expect Closed: 10/12/2017
Reason Closed
Enter Field Notes Below
Notes:
Notes Taken By: Date:
http://user.govoutreach.com/laquintaca/printrequest.php?curid=3430011 &type=0 9/21/2017
Preventative Maintenance Checklist. Level 1
Date I 2--7 ("1 Intersection DO f\
l ( I Vacuum and inspect all cabinets for damage, graffiti or function. (Cooling fan operation)
0 Record BBS Log Events Run time= U. 0
Dust and clean cabinet shelves and componants. Clean dust filter
0 Inspect controller event Log. Note any repeating issues.
Check for controller telemetry with master.
Monitor vehicle detection for all phases. Repair any errors.
Inspect all approaching phases for roadway or sidewalk damage.
Inspect all signal poles for damage.
Inspect signal LED's for operation and brightness. Replace as necessary.
Inspect all traffic control signs for all approaches.
1711 Monitor traffic flow and operational smoothness. Notify traffic engineer of any issues.
Note if cabinet need video breaker panel and/or video monitor.
Insert new log pages if needed.
Technician J05t- VIIaIrA
F— 1" vN5or f,5 r 14 , 5 hAnyn� Tro+-, rolG-
Print Request
r—
Request: 30558 Entered on: 10/31/2017 09:16 AM By: Jose Villalta
Customer Information -
Name: Jose Villalta
Address:
Phone:
Alt. Phone:
Email:
Request Classification - - --
Topic: Traffic Signals -1082 Request type: Maintenance
Status: Open Priority: Normal
Assigned to: Kristopher Gunterson Entered Via: Internal
Problem Location: Miles Ave & Dune Palms Rd
Dandmion Dr
rr
Z
0 Proequities
Miles Ave •
Miles Ave Miles Ave
[; ,; ;.Ii 1912017 Oflr.gle
Original Date:
Time of Day:
Reoccurs Every:
Intersection: Dune Palms and Miles
Description
Perform Level 1 Preventative Maintenance.
Reason Closed
Date Expect Closed: 11/30/2017
Enter Field Notes Below
Notes:
Notes Taken By:
Date:
Page 1 of 1
http:Huser.govoutreach.com/laquintaca/printrequest.php?curid=3490150&type=0 11/27/2017