BPOL2021-0191Permit Details PERMIT NUMBER
City of La Quinta BPOL2021-0191
4
Description: LENNAR/ POOL,SPA,BBQ AND FIRE PIT AT SIDE YARD
Type: POOL CONSTRUCTION Subtype: PRIVATE Status: FINALED
(WEB)
Applied: 6/14/2021 ECON
Approved: 6/24/2021 JAN
Issued: 7/6/2021 AHI
Finaled: 11/9/2021 AMOR
Expired:
Parcel No: 767770030 Site Address: 81688 MERV GRIFFIN WY LA QUINTA,CA 92253
Subdivision: TR 32879 Block: Lot: 23
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $20,000.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: LENNAR/ POOL AND SPA AT SIDE YARD. [2] GAS OUTLETS AT SIDE YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS
REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR
INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD
SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE.
Process Summary
126
Applied to Approved
Approved to Issued
Issued to Finaled
CHRONOLOGY
CHRONOLOGY TYPE 1 STAFF NAME
ACTION DATE 1 COMPLETION DATE
NOTES
E-MAIL
JULIO ANAYA
6/24/2021
6/24/2021
INFORMED APPLICANT PERMIT IS APPROVED AND READY
FOR ISSUANCE,
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
TESERRA
P 0 BOX 1280
COACHELLA
CA
92236
(760)340-9000
KEVING@TESERRAOUT
DOORS.COM
CONTRACTOR
TESERRA
P 0 BOX 1280
COACHELLA
CA
92236
(760)340-9000
KEVING@TESERRAOUT
DOORS.COM
OWNER
IOTA GRIFFIN
P 0 BOX 1280
COACHELLA
CA
92236
(760)340-9000
KEVING@TESERRAOUT
DOORS.COM
FINANCIAL INFORMATION
Printed: Monday, July 24, 2023 12:47:56 PM
1 of 5
CRWSYSTEMS
Permit Details
City of La Quints
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
■ ■
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
7/6/21
R65903
164107
CHECK
TESERRA
AHI
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $1.00 $1.00
DEVICES, FIRST 20
101-0000-42403
0
$26.83
$26.83
7/6/21
R65903
164107
CHECK
TESERRA
AHI
DEVICES, FIRST 20 PC
101-0000-42600
0
$26.83
$26.83
7/6/21
R65903
164107
CHECK
TESERRA
AHI
Total Paid for ELECTRICAL 2019: $53.66 $53.66
GAS SYSTEM, 1-4
OUTLETS
101-0000-42401
0
$13.42
$13.42
7/6/21
R65903
164107
CHECK
TESERRA
AHI
GAS SYSTEM, 1-4
OUTLETS PC
101-0000-42600
0
$26.83
$26.83
7/6/21
R65903
164107
CHECK
TESERRA
AHI
Total Paid for PLUMBING 2019: $40.25 $40.25
SWIMMING POOL/SPA
101-0000-42404
0
$201.25
$201.25
7/6/21
R65903
164107
CHECK
TESERRA
AHI
SWIMMING POOL/SPA
PC
101-0000-42600
0
$109.48
$109.48
7/6/21
R65903
164107
CHECK
TESERRA
AHI
Total Paid for POOL / SPA 2019: $310.73 $310.73
RECORDS
MANAGEMENT FEE
101-0000-42416
0
$10.00
$10.00
7/6/21
R65903
164107
CHECK
TESERRA
AHI
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
ENHANCEMENT FEE TECHNOLOGY
502-0000-43611
0
$5.00
$5.00
7/6/21
R65903
164107
CHECK
TESERRA
AHI
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS: $420.64 $420.64
INSPECTIONS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
Printed: Monday, July 24, 2023 12:47:56 PM
2 of 5
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2021-0191
PRE-GUNITE
KKI
8/12/2021
8/12/2021
APPROVED
eTRAKiT Inspection
Request
8/11/2021 3:07 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603409000
e-Mail: KEVING@TESERRAOUTDOORS.COM
UNDERGROUND PLBG
KKI
9/21/2021
9/21/2021
APPROVED
eTRAKiT Inspection
Request
9/20/2021 3:06 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
UNDERGROUND GAS
KKI
9/21/2021
9/21/2021
APPROVED
eTRAKiT Inspection
Request
9/20/2021 3:06 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
UNDERGROUND ELEC
KKI
9/21/2021
9/21/2021
APPROVED
eTRAKiT Inspection
Request
9/20/2021 3:06 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
DECK BOND
KKI
9/24/2021
9/24/2021
NOT READY
eTRAKiT Inspection
Request
9/23/2021 2:07 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
Printed: Monday, July 24, 2023 12:47:56 PM
3 of 5
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2021-0191
DECK BOND
KKI
9/27/2021
9/27/2021
APPROVED
eTRAKiT Inspection
Request
9/24/2021 1:15 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
FOOTINGS
AMOR
10/22/2021
10/22/2021
CANCELED
eTRAKiT Inspection
Request
10/20/2021 2:04 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
PRE -PLASTER
DCL
10/26/2021
10/26/2021
APPROVED
eTRAKiT Inspection
Request
10/23/2021 6:45 AM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
FINAL**
AMOR
11/9/2021
11/9/2021
APPROVED
eTRAKiT Inspection
Request
11/5/2021 2:54 PM TESERRA
Contact Name: TESERRA
Site Address: 81688 MERV GRIFFIN WY
Phone: 7603899222
e-Mail: KEVING@TESERRAOUTDOORS.COM
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RE DATEED
STATUS
REMARKS
NOTES
1ST BLDG NS -
ETRAKIT (1 DAY)
JULIO ANAYA
6/14/2021
6/15/2021
6/24/2021
APPROVED
Printed: Monday, July 24, 2023 12:47:56 PM
4 of 5
CRWSYSTE S
Permit Details
City of La Quinta
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
6/14/2021
EtrakitContractor
1ST SUBMITTAL SITE
PLAN
G.R. lot 23.pdf
1
DOC
6/24/2021
JULIO ANAYA
SITE PLAN (APPROVED)
BPOL2021 0191 SITE
PLAN (APPROVED).pdf
1
IMAGE
8/12/2021
KIRK KIRKLAND
08122021_094242_AM.J
PG
08122021_094242_AM.J
PG
0
Printed: Monday, July 24, 2023 12:47:56 PM 5 of 5
CRWSYSTEMS
DecoSign Envelope ID: 639ACF12-AAB1-4AE2-A14D-53BCDDF54E3C
SPECIFICATIONS
* NO EXISTING LANDSCAPE LIGHTING IN REAR YARD
* NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD.
* PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY
TESERRA DESIGN BASED ON
GRADING PLAN PROVIDED IN
IIBOXII UPLOADED DB/04/20
CDE FOR HS23
1 ❑/❑ 7/2 ❑ 2 1
PL
8'x4' FIRE PIT AT +18" WITH
POURED IN PLACE LIGHT BROOM
FINISH COLORED CONCRETE CAP,
2"-4" BLACK LAVA ROCK MEDIA,
GAS VALVE AND KEY, BURNER
ASSEMBLY, STUCCO AND PAINT
EXTERIOR TO MATCH
ARCHITECTURE
FDS
s
GAS VALVE
9'-0"X3'-0" SMOOTH FINISH AND SEALED
CONCRETE COUNTERTOP AT +36",
ALFRESCO ALXE-36 36" BARBECUE,
DOUBLE STAINLESS STEEL ACCESS
DOORS, LED TASK FLEX LIGHT,
STUCCO AND PAINT EXTERIOR
TO MATCH HOUSE ARCHITECTURE
15" WIDE POURED IN PLACE LIGHT BROOM
FINISH COLORED CONCRETE COPING
AROUND POOL
DS SPA AT 0" WITH POURED IN PLACE LIGHT
rr BROOM FINISH COLORED CONCRETE
COPING, TILE DAM WALL, AND TILE VENEER
EXTERIOR, 6" TILE WATERLINE, PEBBLE
SHEEN INTERIOR FINISH, (6) HYDRO
THERAPY JETS AT ALTERNATE HEIGHTS.
150'
SPA SPLIT MAIN DRAIN SUCTION MINIMUM
3' APART. ANTI -COVERS 10" ASME / ANSI
APPROVED
POOL SPLIT MAIN DRAIN SUCTION MINIMUM
3' APART. ANTI -COVERS 10" ASME / ANSI
APPROVED
BPOL2021-0191
CI TY CF LA QU N TA
BULONGCIVI9ON
REVI EYED FOR
COCE COWL!AV CE
6Y' J.ANAY" DIE: 0612412021
171' - 11" POLYPROPYLENE GAS PIPE
166 SQ. FT.
POOL AREA CONCRETE COPING
3,309 SQ.FT.
PAVER DECKING
�DS 11 `.x10' ALUMAWOOD SOLID TOP PATIO COVER "H"
f POSTS (225 SQ.FT)
AND J-B
"SIENNA WOOD".
16'-5" SB.
LENNAR/ POOL AND SPA AT SIDE YARD. [2] GAS OUTLETS AT SIDE
YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS
REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION.
PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON
SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE
LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR
YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY.
2019 CALIFORNIA BUILDING CODE.
(PATIO
FAN, COLOR TO BE
WITH (4) LED PUCK LIGHTS =
TURF /
T PERMIT)
E—.�-
OX FOR
FUTURE
ON SEPRATE
54'-8" SB.
8'-4" SB.
4'-2"
DS
DS
8' 5a�
19'-7"
3'-0" WD
—Ds
!///ram/
1
5'-5"
8'-3"
INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL COMPLY WITH
SECTION 114 - MANDATORY REQUIREMENTS
EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS
TO THE POOL
POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS
ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY,
FIELD LAYOUT WILL VARY
1'
3
24'
1
8'
19'-6"
1'
1'
1 9'-4"
DS
9'
0"
6
4, 0 /1
■
8'
sdo
9'-6"
11'-1"
— PAVER DECK DRAINS
BY OTHERS, TYP.
1
6'-8"
9'-9"
Sd0
r
�pS 0 „ Stl
S
L
+36" ® e
37'-0" SB.
3'-6"
J
16'-8"
DocuSigned by:
.w�
POOL / SPA LIGHT JUNCTION BOX
POOL / SPA LIGHT ON GROUND FAULT
CIRCUIT INTERRUPTER
TRANSFORMER
SPA AIR LINE
GAS GAS GAS GAS GAS GAS
IN HOUSE RS6
LOCATION
tc4ta NV'Wi(k
87987 D 1 DCODB45p...
6/9/2021
20'x12' ALUMAWOOD SOLID TOP PATIO COVER "H" POSTS
(180 SQ.FT) WITH (8) LED PUCK LIGHTS AND (2) J-BOX FOR
FUTURE FANS, COLOR TO BE SIENNA WOOD
(PATIO ON SEPRATE PERMIT)
n124'-9"
MERV GRIFFIN WAY
LENNAR TO SUPPLY MAIN
GAS, ELECTRIC AND WATER
CONNECTIONS AT POOL
EQUIPMENT AREA
POOL EQUIPMENT: (1) PUMP, (1) FILTER
AND (1) 400,000 BTU HEATER *ALL EQUIPMENT
SHALL BE SEISMICALLY ANCHORED. POOL
EQUIPMENT SHALL BE WATER BONDED AT
THIS LOCATION.
23'-1" SB
33'-3" SB.
i
GAS METER
MAIN HOUSE 200 AMP
ELECTRICAL PANEL
PL
rY 3'-1 "
1
113'-3"
SAFETY FEATURES:
ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN
SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)
ELECTRICAL:
EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE
GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26,
201 9 CALIFORNIA RESIDENTIAL CODE ( BASED ON20181RC)
201 9 CALIFORNIA BUILDING CODE ( BASED ON2018IBC )
20 1 9 CALIFORNIA MECHANICAL CODE ( BASED ON 2018 UMC )
20 1 9 CALIFORNIA PLUMBING CODE ( BASED ON 2018 UPC)TITLE 24.PARTf
®1 9 CALIF®RNIA ELECTRICAL CODE (BASEDON2017NEc)
20 1 9 CALIFORNIA ENERGY GREEN CODE
201 9 CALIFORNIA ENERGY CODE
GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON
PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL
NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR
DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED
IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE
INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE
EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR
OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED
CONSTRUCTION AUTHORIZATION
SALES
DIG
FIELD
PRE-GUNITE
UNDERGROUND
MASONRY
DECK
IPRE-PEBBLE
GUNITE SIZE 40'-0"
14'-0"
SURFACE AREA OF POOL ONLY 560 SQ.FT.
PERIMETER 108 LN.FT. DEPTHS MIN 3'-0"
POOL & SPA COMBINED 640 SQ.FT. / 128 LN.FT.
SPA SPECIFICATIONS
SIZE 9'-0" x 8'-0" SQ. FT. 72 LN. FT 34
SPA DAM WALL WIDTH
NO. OF JETS 6
LIGHT 1 - JLU4C6W50
RAISED SPA AT 0"
SPILLWAY TYP DAM WALL
SPECIAL NOTES
EXCAVATION / STEEL
TYPE
ACCESS FROM STREET
ELEVATION
DEEP END RAMP NO
LOVE SEAT NO
CONCRETE REMOVAL NO
SOD REMOVAL NO
TREE REMOVAL BY NO
IRRIGATION REMOVAL BY
IRRIGATION REPAIR
6"RBB
12" R.B.B.
18" R.B.B.
24"RBB
30" R.B.B.
TAN SHELF DEPTH
ROCK POCKETS
CENTERS
LOADS
LOADS
FT
FT
FT
FT
.ET
PLUMBING
FILTER JANDY SIZE
POOL PUMP JANDY E SIZE
BOOSTER PUMP — SIZE
ADDL PUMP. SIZE
ADDL PUMP — SIZE
HEATER DANDY SIZE 400,000 BTU
CONTROL SYSTEM RS6 IN HOUSE
CHLORINATOR PLC1400 APURE
WIRELESS CONTROL IAQUALINK
IMDUAL
FILLSKMLINE
ER TYPE MP PRODUCTSPORT AUTOFILL
GAS LINE YES STUBS BBQ/FIREPI
W.F. ATTACHED TO POOL
OTHER W.F.
LIGHTS IN POOL 3 - JLU4C12W100
LIGHTS IN SPA 1 - JLU4C6W50
LIGHTS IN W F N/A
580 SQ. FT.
2.7HP VSP
STUB SET EQUIPMENT YES
PLUMBING SIZE 2 1/2" SUCTION & 2 1/2" RETURN
DEEP HEAT PACKAGE N/A
Q360 INFLOOR N/A
ECLIPSE DRAINS N/A
ANTI VORTEX YES
MiSC.
GUNITE
DEEP END RAMP REEF STEP
EXTEND 2nd STEP
LOVESEAT
COPING
CONCRETE
R.B.B. - SEE STEEL
TILE
GLASS TILE
WATERLINE
RBB TILE
TRIM TILE
MAX X 5-0"
6"x6" T.B.S.
DECKING
SQ. FT. SEE NOTES
FINISH
EXPANSION JOINTS
CANTILEVER
DOUBLE CANTILEVER
DRAINS
SLEEVES
STEPS
STEP FACE
TILE BASE
SAND AND VISQUEEN
BANDS
LIGHT BROOM
MOW STRIP
EQUIPOTENTIAL BONDING GRID
WELDED WIRE MES
REBAR
BARBECUE COUNTERTOP
MASONRY
COPING TYPE CONCRETE
R.B.B. FACING TILE
SPILLWAY TYPE -TILE DAM WALL SIZE PER PLAN
STEPS —
PROP. EXT. WALLS '-"'—
PLANTER WALL —"'
RETAINING WALLS
EQUIP. WALLS —
SEAT WALLS
FIREPIT PER PLAN
BARBECUF PER PLAN
SAND SET PAVER
STUCCO AT BARBECUE AND FIREPIT
PAINT AT BARBECUE AND FIREPIT
YES
PEBBLE
LIGHTS POOL 4- JLU4C12W100
LIGHTS SPA 1 - JLU4C6W50
EYE BALL FITTING YES
ECLIPSE DRAINS N/A
DEEP HEAT RETURNS A
ANTI VORTEX YES
Q360 INFLOOR
FENCING
FENCE TYPE
HEIGHT
GATE
GATE REVERSAL
REMOVE & REHANG
EST. START
EST. CCIMPLETION
MISCELLANEOUS
MISTING SYSTEM
TRELLIS PER PLAN
OWNER RESPONSIBILITIES
OWNER TO:
(1) DETERMINE THE APPROXIMATE ELEVATION OF POOL OR SPA AT LAYOUT ON DAY OF EXCAVATION.
(2) TAKE NOTICE THAT POOL AND EQUIPMENT LOCATIONS ARE SUBJECT TO ACCEPTANCE OF
LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT.
(3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED.
(4) AGREE THAT TESERRA IS NOT RESPONSIBLE FOR UNDERGROUND CONDITIONS OR OBJECTS,
AND ANY DAMAGE TO CURBS, SIDEWALKS, DRIVEWAYS, LAWNS, OR OTHER ITEMS IN THE ACCESS AREA.
(5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE
PRIOR TO PREPLASTER INSPECTION.
(6) FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS - DO NOT USE RUBBER HOSE )
(7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT
WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW.
OWNER APPROVES PLAN, POOL AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE.
SIGNATURE(S)
NAME
G
DATE
A CUSTOM PROJECT FOR:
�IFFII� RA\CH LOT 23 / HO
COMMUNITY GRIFFIN RANCH
JOB ADDRESS 81-688 MERV GRIFFIN WAY
HOMEOWNER MOBILE
HOMEOWNER EMAIL
CITY LA QUINTA
PROJECT MANAGER EMAIL danh@teserraoutdoors.com
CUSTOMER NUMBER'
W.L. TILE
TILE
PAVERS
CONCRETE
POTS/BOWLS
PEBB/PLAS
BOULDERS
DATE
06/08/2421
DESIGNED BY
JT GM BM
REVISIONS
SELECTIONS
RKW - WHITE
WHITE DIAMONDS
DRAINAGE NOTE: Drainage and irrigation for p enters and pots, by others,