BPOL2018-0083 - PERMIT DETAILS REPORTADDITIONAL SITES
CHRONOLOGY
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
APPLICANT VACATION POOLS INC P O BOX 10940 INDIO CA 92202 ublester.vpi@gmail.co
m
CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES
PUBLIC COUNTER VISIT AARON HICKSON 8/17/2018 8/17/2018 STEVE LAZERINI DROPPED OFF CHANGE TO BLOCK WALL
LAYOUT
PUBLIC COUNTER VISIT JULIO ANAYA 6/1/2018 6/1/2018 NOTIFY APPLICANT PLANS ARE APPROVED READY TO ISSUE
CONDITIONS
Description: MORROW RANCH / POOL & SPA AT REAR YARD
Type: POOL Subtype: PRIVATE Status: FINALED Applied: 5/29/2018 MFA
Parcel No: 767580013 Site Address: 55075 MONROE ST ST LA QUINTA,CA 92253 Approved: 6/1/2018 JAN
Subdivision: Block: Lot: Issued: 6/1/2018 TFL
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 1/22/2020 crw
Valuation: $250,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: POOL AND SPA AT REAR YARD [TODD LACHER ENGINEERING]. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION
EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY.THIS PERMIT DOES INCLUDE
EQUIPMENT ENCLOSURE 65 LF [CITY SPECS]. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION.
2016 CALIFORNIA BUILDING CODE
REV-1 120LF OF 6' GARDEN WALL AT FRONT O FPROPERTY [CITY SPECS]
PERMIT EXTENSION GRANTED 90-DAYS FROM SEPTEMBER 20, 2019 TO DECEMBER 19, 2019 TO OBTAIN INSPECTION, IF NO
INSPECTION IS OBTAINED THE WORK WILL HAVE BEEN ABANDONED FOR OVER A YEAR AND A NEW PERMIT WILL BE REQUIRED,
WORK WILL NEED TO BE CORRECTED FOR ANY NEW REQUIREMENTS BASED ON DATE OF NEW APPLICATION.
Printed: Monday, July 25, 2022 3:13:39 PM 1 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2018-0083
CONTACTS
NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL
CONTRACTOR VACATION POOLS INC P O BOX 10940 INDIO CA 92202
OWNER SCOTT MORROW 55075 MONROE ST LA QUINTA CA 92253
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
PLAN CHECK/PERMIT
EXTENSION
PROCESSING
101-0000-42600 0 $107.87 $107.87 11/20/19 R56261 1007 CHECK VACATION POOLS INC AHI
RE-INSPECTION FEE 101-0000-42400 0 $80.50 $80.50 12/17/19 R57189 1187 CHECK SCOTT MORROW JLIM
Total Paid for ADMINISTRATIVE: $188.37 $188.37
WALL/FENCE - EA
ADDITIONAL 50 LF 101-0000-42404 0 $31.20 $31.20 8/15/18 R38587 0001 DEBIT STEPHEM LAZARINI AHI
WALL/FENCE - FIRST
100 LF 101-0000-42404 0 $52.01 $52.01 7/6/18 R37278 09045 CHECK VACATION POOLS INC MFA
WALL/FENCE - FIRST
100 LF PC 101-0000-42600 0 $65.02 $65.02 7/6/18 R37278 09045 CHECK VACATION POOLS INC MFA
Total Paid for BLOCK WALL: $148.23 $148.23
BSAS SB1473 FEE 101-0000-20306 0 $10.00 $10.00 6/1/18 MR575 8853 CHECK VACATION POOLS INC AMA
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $10.00 $10.00
SWIMMING POOL/SPA 101-0000-42404 0 $195.05 $195.05 6/1/18 MR575 8853 CHECK VACATION POOLS INC AMA
SWIMMING POOL/SPA
PC 101-0000-42600 0 $106.11 $106.11 6/1/18 MR575 8853 CHECK VACATION POOLS INC AMA
Total Paid for POOL / SPA: $301.16 $301.16
RECORDS
MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 6/1/18 MR575 8853 CHECK VACATION POOLS INC AMA
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
Printed: Monday, July 25, 2022 3:13:39 PM 2 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2018-0083
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED
DATE
COMPLETED
DATE
RESULT REMARKS NOTES
PRE-GUNITE JFU 6/4/2018 6/4/2018 PARTIALLY
APPROVED
-HORIZONTAL REINFORCEMENT MISSING AT
RAISED BOND BEAM AT WEST-PROVIDE
DETAILING FOR BOULDERS TO BE PLACED
ON BOND BEAM-PROVIDE CUT SHEET FOR
NICHE-LESS LIGHT FIXTURES TO VERIFY NO
BONDING REQUIRMENTOK TO GUNITE
OTHER AREAS. EXPANSION JOINT DOWELS
PER SITE SPECIFIC DESIGN TO BE PLACED
WITH DURING GUNITE INSTALLATION.
UPDATE: LIGHT FIXTURE CUT SHEET
RECEIVED (ATTACHED).
UNDERGROUND ELEC JFU 6/4/2018 6/4/2018 CANCELED
UNDERGROUND GAS JFU 6/4/2018 6/4/2018 CANCELED
UNDERGROUND PLBG JFU 6/4/2018 6/4/2018 CANCELED
PRE-GUNITE JFU 6/5/2018 6/5/2018 APPROVED
UNDERGROUND ELEC JFU 6/22/2018 6/22/2018 PARTIALLY
APPROVED
FROM POOL SHELL TO EQUIPMENT AREA
ONLY.
UNDERGROUND GAS JFU 6/22/2018 6/22/2018 NOT READY NO UNDERGROUND GAS PIPING INSTALLED
AT THIS TIME.
UNDERGROUND PLBG JFU 6/22/2018 6/22/2018 APPROVED
DECK BOND JFU 6/28/2018 6/28/2018 APPROVED
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT #CHECK #METHOD PAID BY CLTD
BY
TECHNOLOGY
ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/1/18 MR575 8853 CHECK VACATION POOLS INC AMA
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS:$662.76 $662.76
Printed: Monday, July 25, 2022 3:13:39 PM 3 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2018-0083
FOOTINGS JAN 7/13/2018 7/13/2018 APPROVED
BOND BEAM JFU 7/17/2018 7/17/2018 APPROVED
TOP-OUT AT EQUIPMENT ENCLOSURE WALL
(PHOTO ATTACHED).
TOP-OUT AT EQUIPMENT ENCLOSURE WALL
(PHOTO ATTACHED).
PRE-PLASTER JFU 8/15/2018 8/15/2018 DISAPPROVE
D
POOL BARRIER IS NOT IN PLACE AT THIS
TIME, AND NO DOOR ALARMS INSTALLED.
PRE-PLASTER JFU 8/17/2018 8/17/2018
APPROVED
W/EXCEPTIO
N
TEMPORARY FENCE INSTALLED AT FRONT OF
LOT. THIS FENCE MUST BE REMOVED AND
THE CMU WALL POOL BARRIER
CONSTRUCTED PRIOR TO FINAL APPROVAL.
ADDITIONALLY, VERIFICATION OF A SECOND
DROWNING PREVENTION DEVICE IS
REQUIRED AT FINAL INSPECTION.
FOOTINGS JFU 8/17/2018 8/17/2018 DISAPPROVE
D
WALLS NOT LOCATED PER PLAN. ALSO,
DIMENSION NEEDED FROM FACE OF CURB
TO PROVIDE REFERENCE DETERMINE
PROPER LOCATION OF WALL.
ADDITIONALLY, SPOKE TO CONTRACTOR
REGARDING CITY STANDARD DESIGN
UTILIZED AS ONLY (9) COURSES MAY BE
CONSTRUCTED, WHICH AT THE ELEVATION
THE FOOTING IS CONSTRUCTED NOW WILL
NOT ALLOW FOR WALL HEIGHT TO MATCH
ADJACENT CMU WALLS.
FINAL**DCL 11/14/2018 11/14/2018 DISAPPROVE
D
- PROVIDE DOOR ALARMS AT POOL EGRESS
DOORS.- PROVIDE SECOND DROWNING
SAFETY FEATURE.- WIRING UNDERSIZED
FOR 70 AMP OVERCURRENT PROTECTION.
NUMBER SIX INSTALLED ON SITE.- EAST
PROPERTY WALL, FUNCTIONING AS A POOL
BARRIER, IS INCOMPLETE AND NOT
CONTINUOUS.
FINAL**JFU 12/4/2018 12/4/2018 CANCELED
Printed: Monday, July 25, 2022 3:13:39 PM 4 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2018-0083
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 9/20/2019 AJ ORTEGA PERMIT EXTENSION
APPROVAL
BPOL2018-0083 -
PERMIT EXTENSION
APPROVAL.pdf
1
BOND INFORMATION
BOND BEAM JFU 11/21/2019 11/21/2019 PARTIALLY
APPROVED
TOP-OUT AT ALL AREAS EXCEPT THE LAST 4'
OF THE NORTHERN PORTION OF THE WALL
ABUTTING THE EXISTING CMU WALL.
FOOTINGS JFU 11/21/2019 11/21/2019 APPROVED
COMPLETE APPROVAL AT FRONT PROPERTY
LINE WALL. INCLUDES RESOLUTION OF
PREVIOUS COMMENTS AND INSPECTION OF
THE LAST REMAINING AREA.
BOND BEAM JFU 11/26/2019 11/26/2019 APPROVED TOP-OUT AT REMAINDER OF CMU WALL AT
FRONT P/L.
FINAL**JFU 12/9/2019 12/9/2019 CANCELED
- INSPECTION BY JAKE REQUESTED BY
CONTRACTOR FOR 12/9
CANCELED BY LESTER W/ VACATION POOLS.
FINAL**JFU 12/10/2019 12/10/2019 DISAPPROVE
D
-VEHICLE GATE IS NOT SELF-CLOSING AT THIS
TIME (MOTOR DISCONNECTED)
-THE FRONT CMU WALL MUST BE FINISHED
WITH STUCCO, PAINT OR OTHER APPROVED
MATERIAL PRIOR TO FINAL APPROVAL
FINAL**JFU 1/22/2020 1/22/2020 APPROVED PREVIOUS CORRECTIONS RESOLVED.
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS REMARKS NOTES
1ST BLDG NS (1
DAY)
JULIO ANAYA 5/29/2018 5/30/2018 6/1/2018 APPROVED
PARENT PROJECTS
Printed: Monday, July 25, 2022 3:13:39 PM 5 of 6
Permit Details
City of La Quinta
PERMIT NUMBER
BPOL2018-0083
ATTACHMENTS
Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED
DOC 9/20/2019 AJ ORTEGA PERMIT EXTENSION
REQUEST
BPOL2018-0083 -
PERMIT EXTENSION
REQUEST.pdf
1
DOC 6/4/2018 JAKE FUSON LIGHT FIXTURE CUT
SHEET
LIGHT FIXTURE CUT
SHEET.pdf 1
IMAGE 7/17/2018 JAKE FUSON TOP-OUT BOND BEAM
PHOTO
BPOL2018-0083 - TOP-
OUT BOND BEAM
PHOTO.jpg
1
Printed: Monday, July 25, 2022 3:13:39 PM 6 of 6