Loading...
BRES2019-0038 Title 24L _ BUILDING ENERGY ANALYSIS REPORT I PROJECT: Custom Residence -The Madison Club Lot 18-13, 52355 Meriwether La Quinta, CA 92253 Project Designer: < Mark Radford Architecture z _O m w 2282 Via Cascabel Escondido, CA w z 92027 D iO LU O �- (760) 432-0348 g U � p 1 �' Report Prepared by: m L, Tim Scott U Scott Design and Title 24, Inc, 74-818 Velie Way, Suite #8 Palm Desert, CA 92260 (760) 200-4780 Job Number: RECEIVED MAY 062019 Date: CITY OF LA QUINTA 5/3/2019 DESIGN AND DEVELOPMENT DEPARTMENT The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft com k- TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R-PRF-01-E Certificate of Compliance 3 Form RMS-1 Residential Measures Summary 19 Form MF-1 R Mandatory Measures Summary 21 HVAC System Heating and Cooling Loads Summary 25 Zone Load Summary 30 Room Load Summary 35 Room Heating Peak Loads 40 Room Cooling Peak Loads 51 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R-PRF-01 Project Name: Madison Lot 18B Calculation Description: Title 24 Analysis Calculation Date/Time: 11:06, Fri, May 03, 2019 Input File Name: Madison Lot 18B-Radford-19.ribd16x Page 1 of 16 GENERAL INFORMATION 01 Project Name Madison Lot 18B 02 Calculation Description Title 24 Analysis 03 Project Location Lot 18-13, 52355 Meriwether 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 12 Building Type Project Scope Single Family Newly Constructed 11 13 Front Orientation (deg/Cardinal) Number of Dwelling Units 90 1 14 Total Cond. Floor Area (ft2) 10447 1S Number of Zones 11 16 Slab Area (ft2) 10447 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes �20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 27.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing andlor verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) ndard Design Proposed Design Compliance Margin Percent Improvement Space Heating Space Cooling IAQ Ventilation 2.51 72.33 0.69 5.09 69.68 0.69 -2.58 2.65 0.00 -102.8% 3.7% 0.0% Water Heating 1.57 1.36 0.21 13.4% Photovoltaic Offset ---- 000 0.00 ---- Compliance Energy Total = 77.10 76.82 0.28 0.4% Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x ENERGY DESIGN RATING CF1 R-PRF-01 Page 2 of 16 Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 44.8 44.7 0.0 44.7 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALG►e¢n A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) %J# • IAQ mechanical ventilation Cooling System Verifications:"'° • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verificafions • --None -- f Registration Number: Registration DaterTime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01 Project Name: Madison Lot 18B Calculation Daterrime: 11:06, Fri, May 03, 2019 Page 3 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Number of Dwelling Number of Ventilation Number of Water Project Name Conditioned Floor Area (ftZ) Units Number of Bedrooms Number of Zones Cooling Systems Heating Systems Madison Lot 18B 10447 1 6 11 0 1 ZONE INFORMATION 01 02 03 05 06 07 Zone Floor Area Avg. Ceiling Zone Name Zone Type HVAC System Name (ftZ) Height Water Heating System 1 Water Heating System 2 Master Conditioned HVAC Zone 31 1398 11.6 DHW Sys 1 n/a Kitchen/Utility Conditioned HVAC Zone 31 e� 1297 112 DHW Sys 1 n/a Office Conditioned HVAC Zone 12 833 12 DHW Sys 1 n/a Bedroom 2 Conditioned HVAC Zone 12 0 712 10 DHW Sys 1 n/a Bar Conditioned HVAC Zone 12 `�� 343 12 DHW Sys 1 n/a Living/Foyer Conditioned HVAC Zone 23 1425 14 DHW Sys 1 n/a Flex Conditioned HVAC Zo 23 609 12 DHW Sys 1 n/a Rec Room Conditioned HVAC Zone 44 956 12 DHW Sys 1 n/a Bedroom 3/Hall Conditioned HVAC Zone 44 777 10 DHW Sys 1 n/a Bedroom 4 Conditioned HVAC Zone 44 466 10 DHW Sys 1 n/a Guest Conditioned HVAC Zone 55 4 1631 12 DHW Sys 1 n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 4 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ftZ) Window & Door Area (ftZ) Tilt (deg) N Wall Master R-21 Wall (W.21.2x6.16) 0 Right 660 98.9 90 E Wall Master R-21 Wall (W.21.2x6.16) 90 Front 45 0 90 S Wall Master R-21 Wall (W.21.2x6.16) N 80 Left 276 66 90 W Wall Master R-21 Wall (W.21.2x6.16) Back 405 198 90 Interior Surface Master»Kitchen/Utility R-0 Interior Wall ; n/a n/a 120 0 n/a Roof -pitched Master R-38 Pitched Roof w/ R.--I, n/a n/a 1398 n/a n/a N Wall 2 Kitchen/Utility R-21 Wall (W.21.2x6.16) 0 Right 170 24.3 90 W Wall 2 Kitchen/Utility R-21 Wall (W.21.2x6.16) 270 Back 143 0 90 Interior Surface 2 Kitchen/Utility»Flex R-0 Interio*,all n/a n/a 260 0 n/a Interior Surface 3 Kitchen/Utility»Master R-0 Interior Wall n/a n/a 120 0 n/a Interior Surface 4 Kitchen/Utility»Living/Foyer R-13'Wall n/a n/a 300 0 n/a Roof -pitched 2 Kitchen/Utility R-38 Pitied Roof w/ R-1 n/a n/a 1297 n/a n/a N Wall 3 Office R-21 Wall (W.21.2x6 16) 0 Right 120 113.3 90 E Wall 2 Office R 21 Wall (W.21-2x6.16) 90 Front 321 113.3 90 S Wall 2 Office E7R-21 Wall (W.21.2x6.16) 180 Left 380 92.5946 90 W Wall 3 Office ti R-21 Wall (W.21.2x6.16) 270 Back 40 0 90 Interior Surface 5 Interior Surface 6 Office»Bar.° Office»Bedroom 2 TY; R-0 Interior Wall R-0 Interior Wall n/a n/a n/a n/a 200 320 0 0 n/a n/a Roof -pitched 3 Office R R-38 Pitched Roof w/ R-1 n/a n/a 833 n/a n/a N Wall 4 Bedroom 2 R-21 Wall (W-21.2x6.16) 0 Right 95 0 90 E Wall 3 Bedroom k R-21 Wall (W.21.2x6.16) 90 Front 80 0 90 S Wall 3 Bedroq R-21 Wall (W.21.2x6.16) 180 Left 320 16.2 90 W Wall 4 Bedroom 2 R-21 Wall (W.21.2x6.16) 270 Back 240 120 90 Interior Surface 7 Bedroorn 2—Living/Foyer R-0 Interior Wall n/a n/a 160 0 n/a Interior Surface 8 Bedroom 2»Office R-0 Interior Wall n/a n/a 320 0 n/a Roof -pitched 4 Bedroom 2 R-38 Pitched Roof w/ R-1 n/a n/a 712 n/a n/a E Wall 4 Bar R-21 Wall (W.21.2x6.16) 90 Front 150 137.5 90 Interior Surface 9 Bar R-0 Interior Wall n/a n/a 500 0 n/a Interior Surface 10 '4 Bar»Office R-0 Interior Wall n/a n/a 200 0 n/a Interior Surface 11 Bar»Living/Foyer R-0 Interior Wall n/a n/a 340 0 n/a Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x Page 5 of 16 Roof -pitched 5 Bar R-38 Pitched Roof w/ R-1 n/a n/a 343 n/a n/a E Wall 5 Living/Foyer R-21 Wall (W.21.2x6.16) 90 Front 415.8 346,522 90 W Wall 5 Living/Foyer R-21 Wall (W.21.2x6.16) 270 Back 632 572 90 Interior Surface 12 Living/Foyer»Bedroom 2 R-0 Interior Wall n/a n/a 160 0 n/a Interior Surface 13 Living/Foyer»Bar R-0 Interior Wall n/a n/a 340 0 n/a Interior Surface 14 Living/Foyer»Kitchen/Utility R-13 Wall n/a n/a 300 0 n/a Interior Surface 15 Living/Foyer»Flex R-0 Interior Wall r`'n/a n/a 375 0 n/a Roof -pitched 6 Living/Foyer R-38 Pitched Roof w/ R-1 "�� n/a n/a 1425 n/a n/a E Wall 6 Flex R-21 Wall (W.21.2x6.16) 90 Front 138 113.3 90 S Wall 4 Flex R-21 Wall (W.21.2x6.16) 180 Left 132 113.3 90 Interior Surface 16 Flex»Living/Foyer R-0 Interior Wall n/a n/a 375 0 n/a Interior Surface 17 Flex»Kitchen/Utility R-0 Interior WIM n/a n/a 260 0 n/a Roof -pitched 7 Flex R-38 Pitched Roof w/ R-1 n/a n/a 609 n/a n/a N Wall 5 Rec Room R-21 Wall (W.21.2x6.16) 0 Right 324 132 90 S Wall 5 Rec Room R-21 Wall ".21.24.16) 180 Left 324 264 90 W Wall 6 Rec Room R-2144all (W.21.2x6.16) 270 Back 54 0 90 Interior Surface 18 Rec Room»Bedroom 3/Hall Ft-0 Interior Wall n/a n/a 120 0 n/a Interior Surface 19 Rec Room»Bedroom 4 ., R-0 Interior Wall n/a n/a 160 0 n/a Roof -pitched 8 Rec Room i2-38 Pitched Roof w/ R-1 n/a n/a 956 n/a n/a N Wall 6 Bedroom 3/Hall R-21 Wall (W.21.2x6.16) 0 Right 60 48 90 E Wall 7 Bedroom 3/Hall R-21 Wall (W.21.2x6.16) 90 Front 280 24 90 S Wall 6 Bedroom 3/Hall R-21 Wall (W.21.2x6.16) 180 Left 310 47.5 90 W Wall 7 Bedroom 3/Hall'Fa R-21 Wall (W 21.2x6.16) 270 Back 115 0 90 Interior Surface 20 Bedroom 3/Hall—Bedroom 4 R-0 Interior Wall n/a n/a 210 0 n/a Interior Surface 21 Bedroom 3/Hall>,>Jiec Room R-0 Interior Wall n/a n/a 120 0 n/a Roof -pitched 9 Bedroom 3/Hap R-38 Pitched Roof w/ R-1 n/a n/a 777 n/a n/a N Wall 7 Bedroom 4 R-21 Wall (W.21.2x6.16) 0 Right 240 11.7 90 E Wall 8 Bedroom 4 R-21 Wall (W.21.2x6.16) 90 Front 190 0 90 Interior Surface 22 Bedr4—Bedroom 3/Hall R-0 Interior Wall n/a n/a 210 0 n/a Interior Surface 23 Bedroom 4»Rec Room R-0 Interior Wall n/a n/a 160 0 n/a Roof -pitched 10 6- Bedroom 4 R-38 Pitched Roof w/ R-1 n/a n/a 466 n/a n/a N Wall 8 Guest R-21 Wall (W.21.2x6.16) 0 Right 528 110 90 E Wall 9 Guest R-21 Wall (W 21.2x6.16) 90 Front 459 104.2 90 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 6 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x S Wall 7 Guest R-21 Wall (W.21.2x6.16) 180 Left 480 40 90 W Wall 8 Guest R-21 Wall (W.21.2x6.16) 270 Back 495 20.07 90 Interior Surface 24 Guest»Living/Foyer R-0 Interior Wall n/a n/a 5 0 n/a Roof -pitched 11 Guest R-38 Pitched Roof w/ R-1 n/a n/a 1631 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise 41 1 Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Attic RoofMaster Ventilated 3 �r' 0.1 0.85 Yes No Attic Kitchen/Utility Attic RoofKitchen/Utility Ventilated 0.1 0.85 Yes No Attic Office Attic RoofOffice Ventilated 3 0.1 0.85 Yes No Attic Bedroom 2 Attic RoofBedroom 2 Ventilated '� 3 01 0.85 Yes No Attic Bar Attic RoofBar Ventilated 3 0.1 0.85 Yes No Attic Living/Foyer Attic RoofLiving/Foyer Ventilated 0.1 0.85 Yes No Attic Flex Attic RoofFlex Ventilated 3 0.1 0.85 Yes No Attic Rec Room Attic RoofRec Room Ventilated �, 3 0.1 0.85 Yes No Attic Bedroom 3/Hall Attic RoofBedroom 3/Hall Ventilateds, 3 0.1 0.85 Yes No Attic Bedroom 4 Attic RoofBedroom 4 Ventilated 3 0.1 0.85 Yes No Attic Guest Attic RoofGuest Ventilated 3 0.1 0.85 Yes No oe V Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x Page 7 of 16 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading 3X5 Window N Wall (Right-0) ---- - 1 15.0 0.39 0.31 Insect Screen (default) 3X5 2 Window N Wall (Right-0) - - 1 15.0 0.39 0.31 Insect Screen (default) 2.5X2.5 Window N Wall (Right-0) ---- ---- 1 6.3 0.50 0.26 Insect Screen (default) 2.5X10 Window N Wall (Right-0) ---- - 1 25.0 0.39 0.31 Insect Screen (default) 2.5X10 2 Window N Wall (Right-0) --- 1 25.0 0.39 0.31 Insect Screen (default) 2.5X2 5 2 Window N Wall (Right-0) - - 1 6.3 0.50 0.26 Insect Screen (default) 2.5X2.5 3 Window N Wall (Right-0) ---- -- 1 6.3 0.50 0.26 Insect Screen (default) 6X11 18X11 Window Window S Wall (Left-180) W Wall (Back-270) 6.0 18.0 11.0 11.0 1 1 66.0 198.0 0.39 0.39 0.32 0.32 Insect Screen (default) Insect Screen (default) 4X4.5 Window N Wall 2 (Right-0) --- ---- 1 18.0 0.50 0.26 Insect Screen (default) 4X4.5 2 Window N Wall 2 (Right-0), ---- -- 1 6.3 0.50 0.26 Insect Screen (default) 10.3X11 Window N Wall 3 (Right-0) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 10.3X11 2 Window E Wall 2 (Front 90) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 6X11 2 Window S Wall 2 (Left•180) - -- 1 66.0 0.39 0.31 Insect Screen (default) 2.7X2.7 Window S Wall 2 (Left-180) 2.7 2.7 1.001 7.3 0.50 0.26 Insect Screen (default) 3X4 Window S Wall 2 (Left-180) 3.0 4.0 1 12.0 0.39 0.31 Insect Screen (default) 2.7X2.7 2 Window S WalI 2 (Left-180) 2.7 2.7 1.001 7.3 0.50 0.26 Insect Screen (default) 2X2.7 Window 8 Wall 3 (Left-180) ---- - 1 5.4 0.50 0.26 Insect Screen (default) 4X2 7 Window S Wall 3 (Left-180) - ---- 1 10.8 0.50 0.26 Insect Screen (default) 12X10 Window W Wall 4 (Back-270) 12.0 10.0 1 120.0 0.39 0.32 Insect Screen (default) 12.5X11 Window E Wall 4 (Front-90) 12.5 11.0 1 137.5 0.39 0.31 Insect Screen (default) 12.6X11 Window E Wall 5 (Front-90) 19.0 11.0 0.663 138.6 0.39 0.31 Insect Screen (default) 6.3X11 Window E Wall 5 (Front-90) 19.0 11.0 0.332 69.4 0.92 0.59 Insect Screen (default) 12.6X11 2 Window E Wall 5 (Front-90) 19.0 11.0 0.663 138.6 0.39 0.31 Insect Screen (default) 44X13 Window W Wall 5 (Back-270) 44.0 13.0 1 572.0 0.39 0.32 Insect Screen (default) 10.3X11 3 Window E Wall 6 (Front-90) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 10.3X11 4 Window S Wall 4 (Left-180) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 6X11 3 Window N Wall 5 (Right-0) ---- - 1 66.0 0.50 0.26 Insect Screen (default) 6X11 4 Window N Wall 5 (Right-0) - 1 660 0.50 0.26 Insect Screen (default) Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 8 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x 24X11 Window S Wall 5 (Left-180) 24.0 11.0 1 264.0 0.39 0.32 Insect Screen (default) 6X8 Window N Wall 6 (Right-0) ---- ---- 1 48.0 0.50 0.26 Insect Screen (default) 2.5X3 Window S Wall 6 (Left-180) 1 7.5 0.50 0.26 Insect Screen (default) 8X5 Window S Wall 6 (Left-180) ---- ---- 1 40.0 0.50 0.26 Insect Screen (default) 8X5 2 Window N Wall 7 (Right-0) ---- 1 5.4 0.51 0.26 Insect Screen (default) 2.5X3 2 Window N Wall 7 (Right-0) ---- --- 1 6.3 0.50 0.26 Insect Screen (default) 10X11 Window N Wall 8 (Right-0) 10.0 �?f r 11.0 1 110.0 0.39 0.32 Insect Screen (default) 3X8 Window E Wall 9 (Front-90) 1 24.0 0.51 0.26 Insect Screen (default) 8X8 Window E Wall 9 (Front-90) 1 64.0 0.50 0.26 Insect Screen (default) 6X2.7 Window E Wall 9 (Front-90) -- 1 16.2 0.50 0.26 Insect Screen (default) 8X5 3 Window S Wall 7 (Left-180) ..-• 1 40.0 0.50 0.26 Insect Screen (default) 2.5X3 3 Window W Wall 8 (Back-270) 1 7.5 0.50 0.26 Insect Screen (default) 3.5X4.5 Window W Wall 8 (Back-270) --- 1 6.3 0.50 0.26 Insect Screen (default) 15X11 Window W Wall 8 (Back-270) 15.0 11.0 0.038 1 6.3 0.39 0.32 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft) U-factor Door = 't E Wall 7 24.0 0.50 %6q 4. 14�2 401z� Registration Number: Registration DatefFime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Description: Title 24 Analysis Calculation Date/Time: 11:06, Fri, May 03, 2019 Input File Name: Madison Lot 18B-Radford-19.ribdl6x CF1 R-PRF-01 Page 9of16 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 6X11 4 0.1 4 4 0 0 0 0 0 0 0 0 18X11 8 0.1 8 8 0 0 0 0 0 0 0 0 0 10.3X11 10 0.1 10 10 0 0 0 0 0 0 0 0 0 10 3X11 2 18 0.1 18 18 0 0 0 0 0 0 0 0 0 2.7X2.7 3 0.1 3 0 0 0 0 0 0 0 0 0 0 3X4 3 0.1 3 0 0 0 0 0 0 0 0 0 0 2.7X2.7 2 3 0.1 3 0 `& 0 0 0 0 0 0 0 0 12X10 14 0.1 14 14 0 0 0 0 0 0 0 0 0 12.5X11 14 0.1 14 14 0 0 0 0 0 0 0 0 0 12.6X11 14 0.1 14 14� O 0 0 0 0 0 0 0 0 0 6.3X11 14 0.1 14 K 0 0 0 0 0 0 0 0 0 12.6X112 14 0.1 14 C14 0 0 0 0 0 0 0 0 0 44X13 22 0.1 22 0 0 0 0 0 0 0 0 0 0 10.3X11 3 8 0.1 8 8 0 0 0 0 0 0 0 0 0 10.3X114 10 0.1 10 10 0 0 0 0 0 0 0 0 0 24X11 12 0.1 42 12 0 0 0 0 0 0 0 0 0 10X11 4 0.1 4 4 0 0 0 0 0 0 0 0 0 15X11 18 0.1� 18 18 0 0 0 0 0 0 0 0 0 Registration Number: Registration DatefFime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CFI R-PRF-01 Page 10 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Attic Roofs Wood Framed Ceiling in. O.0 R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-14.3/2x6 R-38 Pitched Roof w/ R-1 attic) Wood Framed Ceiling 2x6 @ 16 in O.C. R 38 0.026 - Over Ceiling Joists: R-23.7 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall (W.21.2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in, O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco V4.1 Inside Finish: Gypsum Board • Cavity / Frame: no insul. / 2x4 R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0.277 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck., Wood Siding/sheathing/decking Attic RoofKitchen/Utility Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. R 13 0.092 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofOffice Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Around Roof Joists: R-0.0 insul. Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedroom 2 Attic Roofs Wood Framed Ceiling in O C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBar Attic Roofs Wood Framed Ceiling in O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofLiving/Foyer 4ttilyoofs Wood Framed Ceiling in O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Registration Number: Registration DatefFime: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 11 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofFlex Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofRec Room Attic Roofs Wood Framed Ceiling in. O C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedroom 3/Hall Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Around Roof Joists: R-0.0 insul. Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedroom 4 Attic Roofs Wood Framed Ceiling in. Q.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Around Roof Joists: R-0.0 insul. Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGuest Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab Master 1398 125 None 0.8 No Slab 2 Kitchen/Utility 1297 125 None 0.8 No Slab 3 Office 833 73 None 0.8 No Slab 4 Bedroom 2 712 71 None 08 No Slab 5 Bar 343 14 None 0.8 No Slab 6 Living/FNpr 1425 125 None 08 No Slab 7 Flax 609 23 None 0.8 No Slab 8 Rec Room 956 76 None 0.8 No Slab 9 Bedroom 3/Hall 777 71 None 0.8 No Slab 10 Bedroom 4 466 14 None 0.8 No Slab 11 $4/ Guest 1631 184 None 0.8 No Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 12 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy. Pilot / Insulation Loss I First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor / Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small Instantaneous 2 0 0.95 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC Zone 31 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC Zone 12 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC Zone 23 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC Zone 44 Otiper Heatina and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC Zone 55 Other Heating and Cooling System Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Datefrime: 11:06, Fri, May 03, 2019 CFI R-PRF-01 Page 13 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 1 80 AFUE Heating Component 4 CntrlFurnace 1 80 AFUE Heating Component 5 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 -C' Efficiency Name System Type Number of Units Kw EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 13 16 Not Zonal Single Speed Cooling Component 4-hers-cool Cooling Component 5 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 5-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool 4' Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Cooling Component 5-hers-cool Required 350 Required Required Required Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CFI R-PRF-01 Page 14 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 2-hers-dist Air Distribution System 3 y DuctsAttic Specified Lower Leakage Target 9 8 Attic None Air Distribution System 3-hers-dist Air Distribution System 4 DuctsAttic Specified Lower Leakage Target Attic None Air Distribution System 4-hers-dist Air Distribution System 5 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 5-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%)�, Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 60 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-dist Required s' 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 5-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.5 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.5 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.5 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.5 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.5 HVAC Fan 5-hers-fan •.0 oe Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 15 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.50 HVAC Fan 2-hers-fan Required 0.50 HVAC Fan 3-hers-fan Required 0.50 HVAC Fan 4-hers-fan Required,QJ 0.50 HVAC Fan 5-hers-fan Required 0.50 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 157 015 Default 0 Required `14 UVO Registration Number: Registration DateRme: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 16 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Tim Scott Company: Signature Date Scott Design and Title 24, Inc, 5/3/2019 Address: 74-818 Velie Way, Suite #8 CEAMERS Certification Identification (If applicable): Zin cay/star F dl:m Desert, CA 92260 PI,°ne (760) 200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California. 1. I am eligible under Division 3 of the Business and Professions Code to accept responsiWity for the building design identified on this Certificate of Compliance 2. 1 certify that the energy features and performance specifications identified on this CeMCate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate. of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application Responsible Des i ner Name: Mark Wa6dford Responsible Designer Signature: Company: Mark Radford Architecture Date Signed: Address: 2282 Via Cascabel License: City/State/Zip: Escondido, CA 92027 ,, Phone: (760) 432-0348 Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Custom Residence -The Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration California Energy Climate Zone Total Cond. Floor Area Addition CA Climate Zone 15 10,447 n/a Date 5/3/2019 # of Units FI Project Address Lot 18-B, 52355 Meriwether La Quinta INSULATION Construction Type Cavity Area WSpecial Features Status Roof Wood Framed Attic Wall Wood Framed Slab Unheated Slab -on -Grade R 38 R 21 no insulation 10,447 Add=R-13.0 5,695 9,670 Perim = 830' New New New Demising Wood Framed - no insulation 5,035 New Demising Wood Framed R 13 600 New Door Opaque Door no insulation 24 New Slab Unheated Slab -on -Grade - no insulation 777 Perim = 71' Altered FENESTRATION Orientation Area ft) Total Area: 2,903 Gsazing Percentage: 278 % U-Fac SHGC Overhang Sidefins NewlAltered Average U-Factor: Exterior Shades 0•42 Status Right (N) 80.0 0.390 0.31 none none Bug Screen New Right (N) 229.5 0.500 0.26 none none Bug Screen New Left (S) 66.0 0.390 0.32 4.0 none Bug Screen New Rear (W) 198.0 0.390 0.32 8.0 none Bug Screen New Right (N) 113.3 0.390 0.32 10.0 none Bug Screen New Front (E) 113.3 0.390 0.32 18.0 none Bug Screen New Left (S) 66.0 0.390 0.31 none none Bug Screen New Left (S) 14.6 0.500 0.26 3.0 none Bug Screen New Left (S) 12.0 0.390 0.31 3.0 none Bug Screen New Left (S) 103.7 0.500 0.26 none none Bug Screen New Rear (M 120.0 0.390 0.32 14.0 none Bug Screen New Front (E) 414.7 0.390 0.31 14.0 none Bug Screen New Front (E) 69.3 0.920 0.59 14.0 none Bug Screen New Rear (W) 572.0 HVAC SYSTEMS Qty. Heating 0.390 0.32 22.0 Min. Eff Cooling none Min. Eff Bug Screen Thermostat New Status 1 Central Furnace 80% AFUE Split Air Conditioner 16.0 SEER Setback New 1 Central Furnace 80% AFUE 1 Central Furnace 80% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 16, 0 SEER Split Air Conditioner 16.0 SEER Cooling Duct Location Setback Setback Duct R-Value New New Status HVAC Zone 3 Ducted HVAC Zone 1 Ducted HVAC Zone 2 Ducted WATER HEATING Qty. Type Ducted Attic 8.0 Ducted Attic 80 Ducted Attic 60 Gallons Min. Eff Distribution New New New Status 2 Small Instantaneous Gas 0 0.95 Standard New Ever Pro 7.2 by EnerqySoft User Number: 6712 ID: Page 19 of 61 RESIDENTIAL MEASURES SUMMARY RMS-1 Project Name Custom Residence -The Madison Club Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 51312019 Project Address Lot 18-8, 52355 Meriwether La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 10,447 Addition n/a # of Units 1 INSULATION Construction Type Area Cavity (ft) Special Features Status FENESTRATION Orientation Area(ft2) Ilicital Area: Z903 G lazing Percentage: 2 7. 6 % U-Fac SHGC Overhang Sidefins New/Altered Averse U-Factor. Exterior Shades 0.42 Status Front (E) 1133 0.390 0.32 8.0 none Bug Screen New Left (S) 1133 0.390 0.32 10.0 none Bug Screen New Left (S) 264.0 0.390 0.32 12.0 none Bug Screen New Right (N) 5.4 0.510 0.26 none none Bug Screen New Right (N) 110.0 0.390 0.32 4.0 none Bug Screen New Front (E) 24.0 0.510 0.26 none none Bug Screen New Front (E) 80.2 0.500 0.26 none none Bug Screen New Rear (VV) 13.8 0.500 0.26 none none Bug Screen New Rear (M 6.3 0.390 0.32 18.0 none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80 % AFUE 1 Central Furnace 80% AFUE HVAC DISTRIBUTION Location Heating Split Air Conditioner 16.0 SEER Split Air Conditioner 16.0 SEER Cooling Duct Location Setback Setback Duct R-Value New New Status HVAC Zone 4 Ducted HVAC Zone 5 Ducted WATER HEATING -Qty. Type Ducted Attic 8.0 Ducted Attic 8.0 Gallons Min. Eff Distribution New New Status EnergyPro 7.2 by Ener�qySoft User Number. 6712 ID: Pape 20 of 61 2016 Low -Rise Residential Mandatory Measures Summary NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach used. Review the respective section for more information. *Exceptions may apply. (Revised 04/2017a Building Envelope Measures: § 110.6(a)l: Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per NFRC-400 orASTME283 orAAMAIWDMAICSA 10l/I.S.2/A440-2011.' § 110.6(a)5 Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a). § 110.6(b): Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES 110.E-A and 110.6-B for compliance and must be caulked and/or weatherstrip ed. ' § 110.7: Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked, asketed, or weather stripped. § 110.8(a): Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material. § 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). § 110.8(i): Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R. § 110.80): Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs. Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043. Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached § 150.0(a): insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited to la�cin insulation either above or below the roof deck or on top of a dD2all ceiling.' § 150.0(b): Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U- § 150.0(c): factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed value of R-13 in a wood framed assembl .' § 150.0(d): Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.` § 150.0(9: Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8. Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This requirement also applies to controlled ventilation crawls ace for buildings complying with the exce tion to § 150.0(d). § 150.0(g)2: Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. 150.0 § (q)' Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.* Fireplaces, Decorative Gas Appliances, and Gas Log Measures: § 150.0(e)lA: Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. § 150.0(e)l B: Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.' § 150.0(e)l C: Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.' § 150.0(e)2: Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating, and Plumbing System Measures: § 110.0-§ 110.1 Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated appliances must be certified by the manufacturer to the Energy Commission.` § 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.' Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters § 110.2(b): must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for compression heating is higher than the cut-off temperature for supplementa heating.* § 110.2(c): Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a setback thermostat.' Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must § 110.3(c)5: meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of § 110.3(c)5. § 110.3(c)7: Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs or other fittings on bath cold water and hot water lines of water heating systems to allow for water tank flushin2 when the valves are closed. § 110.5: Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli- ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters! Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment § 150.0(h)l: Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA Manual J using design conditions specified in 150.0 h 2, 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(h)3A: Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any dryer vent. § 150.0(h)3B: Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by manufacturer's instructions. § 150.00)1: Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have R-12 external insulations or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a § 150.00)2A: nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter; piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to kitchen fixtures.' § 150.00)2B: Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or steeve! § 150.06)2C: Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.' § 150.00)3: Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by § 150.00)3A: aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can cause degradation of the material. § 150.00)3B: _ Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a Class I or Class II vapor retarder. Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a § 150.0(n)1: 120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr. § 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5. § 150 0(n)3, Solar Water -heating Systems. Solar water- heating systems and collectors must be certified and rated by the Solar Rating and Certification Corporation SRCC or by a listing agency -that is approved b the Executive Director. Ducts and Fans Measures: § 110.8(d)3: Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement. CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing § 150.0(m)1: (RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y< inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts: Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction, § 150.0(m)2: connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. § 150.0(m)3: Field -Fabricated Duct Systems. field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes, mastics, sealants, and Other requirements sp2cifled for duct construction. § 150.0(m)7: Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic dampers. § 150.0(m)8: Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible, manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents. Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and § 150.0(m)9: wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation. § 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier. Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an § 150.0(m)11: occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with § 150.0(m)11and Reference Residential Appendix RA3. Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal § 150.0(m)12: conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency, pressure drop, and labeling requirements of § 150.0(m)12. 2016 Low -Rise Residential Mandatory Measures Summary Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the § 150.0(m)13: supply plenum. The space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central forced air systems.' Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor §150.0(o): continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing whole -building ventilation. § 150.0(o)1A: Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic testing, in accordance with Reference Residential Appendix RA3.7. Pool and Spa Systems and Equipment Measures: Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency § 110.4(a): that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric resistance heating.' § 110.4(b)1: Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating. § 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover. § 110.4(b)3: Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. § 110.5: Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light. 150.0 § (p)' Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow rate, piping, filters, and valves.' Lighting Measures: § 110.9: Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements of § 110.9.* § 110.9(e): JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must be certified to the Energy Commission according to Reference Joint Appendix JA8. § 150.0(k)1A: Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A. Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or § 150.0(k)1 B: other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or fanspeed control. Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC) § 150.0(k)1 C: labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings. § 150.0(k)1 D: Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than 20 kHz. Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no § 150.0(k)1 E: more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled by vacancy sensors. § 150.0(k)1 F: Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) must meet the applicable requirements of § 150.0(k).' Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply § 150.0(k)1 G: with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix JA8.' § 150.0(k)1 H: Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E." § 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A. § 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.' § 150.0(k)2C: Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF. § 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions. § 150.0(k)2E: Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with 150.0(k). § 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9. Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it: § 150.0(k)2G functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of § 130.5 ; and meets all other requirements in § 150.0(k)2. Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the § 150.0(k)2H: following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5(f); and all other requirements in 6 150.0(k)2. § 150.0(k)21: Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it provides the functionality of a dimmer according toll 10.9, and complies with all other applicable requirements in § 150.0(k)2. 2016 Low -Rise Residential Mandatory Measures Summary § 150.0(k)2J: Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must be controlled by a vacancy sensor. § 150.0(k)2K: Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallways.* § 150.0(k)2L: Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems. Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other § 150.0(k)3A: buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item § 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control. astronomical time clock, or EMCS). Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, § 150.0(k)3B: and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with either 150.0 k 3A or with theapplicable requirements in §§ 110.9, 130.0, 130.2, 130.4. 140.7 and 141.0. § 150.0(k)3C: Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by 150.0 k 3B or § 150.0 k 30 must comply with the a licable requirements in §§ 110.9,130.0,130.2,130.4, 140.7 and 141.0. § 150.0(k)3D: Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site must comply with the applicable requirements in §§ 110.9. 130.0 130.2, 130.4, 140.7, and 141.0, § 150.0(k)4: Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of power as determined according to § 130.0 c . § 150.0(k)5: Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior § 150.0(k)6A: common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that building must be high efficacy luminaires and controlled by an occupant sensor. Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must: § 150.0(k)6B: I. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least 50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress. Solar Ready Buildings: Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the § 110.10(a)1: application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the requirements of § 110.10 b through § 110.10(e). § 110.10(a)2: Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d). Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas § 110.10(b)1: greater than 10,000 square feet. For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250 square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.' § 110.10(b)2: Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north. § 110.10(b)3A: Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof mounted equipment.' Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the § 110.10(b)313: distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of the nearest point of the solar zone, measured in the vertical plane." § 110.10(b)4: Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load must be clearly indicated on the construction documents. Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for § 110.10(c): routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of interconnection will be the main service panel): and a pathway for routing of plumbing from the solar zone to the water -heating s stem. § 110.10(d): Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through 110.10 C must be provided to the occupant. § 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps. Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit § 110.10(e)2: breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or main circuit location; and permanently marked as "For Future Solar Electric". HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 3 Date 5/3/2019_ Floor Area 2,695 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING CFM Sensible Total Room Loads 2,791 26,638 Return Vented Lighting 0 Return Air Ducts 1,538 Return Fan 0 Ventilation 512 18,974 Supply Fan 0 Supply Air Ducts 1,538 TOTAL SYSTEM LOAD 48,687 PEAK COIL HTG. Latent CFM 3,356 752 -439 512 2,917 PEAK Sensible Heating System Output per System 80 29,517 Total output Btuh 80 Output Btuh/s ft 0.0 1,451 Cooling System 0 Output per System 37,200 2446 ,4 Total Output Btuh 37,200 0 Total Output Tons 3.1 1,451 Total Output Btuh/s ft 13.8 Total Output s ft/Ton 869.4 56,883 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Trane 5 Ton 33,504 4,053 80 Airflow cfm/s ft) 0.45 Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 80 Jan 1 AM Airflow (cfm/Ton) 387.1 Outside Air (%) 42.7 % 33,504 4,053 Outside Air (cfm/s ft) 0.19 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 512 cfm 71 OF 4 52 OF 110 °F Heating Coil Supply Fan 1,200 cfm U-11- T 109 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS JAirstrearn Temperatures at Time of Cooling Peak 112/78OF Outside Air Ar 512 cfm 92/73°F 66/64°F 66/64°F 1 I— f Cooling Coil Supply Fan 67 / 65 °F 1,200 cfm ROO� 67.6 76 / 68 OF FLEE • ' HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 1 Date 5/3/2019 Floor Area 1,888 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,934 Return Vented Lighting Return Air Ducts Return Fan Ventilation 354 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heatinp System Sensible Latent CFM Sensible 26,619 Output perS stem Total Output Btuh) 80 80 24,400 2,351 676 0 Output (Btuh/s ft) 0.0 1,409 1,308 Cooling System 0 0 Output perS stem 37.200 13,142 1.844 354 16,931 Total Output Btuh) 37,200 0 1,409 1 40,359 4, 994 0 Total Output Tons 3.1 1,308 Total Output Btuh/s ft) 19.7 Total output s ft/Ton 609.0 46,173 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Trane 5 Ton 31,101 4,988 80 Airflow cfm/s ft 0.64 Airflow cfm/Ton 387.1 Outside Air % 29•5 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 31,101 4,988 Aug 3 PM 80 Jan 1 AM Outside Air (cfm/s ft) 0.19 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak 26 OF Outside Air 354 cfm 71 OF If 58 OF Heating Coil Supply Fan 1,200 cfm ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78IF Outside Air 354 cfm 87/70OF 63/62OF 63/62OF I F-1 Cooling Coil Supply Fan 1,200 cfm I— U 61.2 % 64 / 62 OF ROOM YJ 7a , nG HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 2 Date 5/3/2019 Floor Area 2,034 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 3,650 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 454 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 80 36,515 2,533 901 35,142 Total Output (Btuh) B0 0 Output Btuh/s ft 0.0 2,108 1,727 Cooling System 0 0 Outgut per System 37,200 16,607 705F 454 21,586 Total Output (Btuh) 37,200 0 3.238 0 Total Output (Tons 3.1 2,108 1,727 Total Output Btuh/s ft 18.3 Total Output s ft/Ton 656.1 1 57,337 60,183 Air System CFM per System 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Trane 5 Ton 32,827 4,255 80 Airflow cfm/s ft 0.59 32,827 4,255 80 Aug 3 PM Jan 1 AM Airflow cfm/Ton 387.1 Outside Air (%) 37.9 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Outside Air (cfm/s ft) 0.22 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 454 cfm 71 OF 54 OF 110 OF 110 °F Heating Coil Supply Fan 1,200 cfm 109 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 112/78OF Outside Air Ak- 454 cfm 91/72°F 65/63°F 65/63°F Cooling Coil Supply Fan 67 / 64 OF 1,200 cfm 65.0 % ROOM 76/�- HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 System Name Floor Area HVAC Zone 4 2,199 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. CFM Sensible Latent CFM Total Room Loads 2,171 25,235 2,738 727 Return Vented Lighting 0 Return Air Ducts 1,4571 Return Fan 0 Ventilation 398 14,779 1,272 398 Supply Fan 0 Supply Air Ducts 1,457 TOTAL SYSTEM LOAD 42,928 4,0710 PEAK Heating System Sensible Output per System 80 28,538 Total Output Btuh) 80 Output (Btuh/s ft) 0.0 1,403 Cooling System 0 Output erS stem 37.200 19,036 Total Output Btuh 37,200 0 Total Output Tons 3•1 1,403 Total Output Btuh/s ft 16.9 Total Output s ft/Ton 709.4 50,379 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Trane 5 Ton 31,642 4,921 Total Adjusted System Output 31,642 4,921 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Aug 3 PM 80 80 Jan 1 AM Airflow cfm/s ft 0.55 Airflow (cfm/Ton) 387.1 Outside Air % 33 2 % Outside Air (cfm/s ft) 0.18 conditions Note: values above given at ARI HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Mating Peak 26 OF —0-0- Outside Air 398 cfm 71 OF 56 OF 110 °F 110 °F IP 0 _ Tr Heating Coil Supply Fan 1,200 cfm 109 OF ROOM 1 72 OF COOLING SYSTEM PSYCHROMETRiCS Airstream Temperatures at Time of Cooling Peak 112/78OF Outside Air 398 cfm 77/67°F 89/71 OF 64/62°F 64/62°F op a LLLLU Cooling Coil Supply Fan 65 / 63 OF 1,200 cfm 63.3 % ROOM 76/67°F HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Custom Residence -The Madison Club _ System Name HVAC Zone 5 Date 5/3/2019 Floor Area 1,631 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 _ COIL CFM Total Room Loads 1.447! Return Vented Lighting Return Air Ducts Return Fan Ventilation 326 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 80 19,669 2,031 587 23,194 Total Output Btuh 80 0 Output Btuh/s ft 0.0 1,135 1,140 Cooling System 0 0 Output perSystem 37,200 12,189 2,217 326 15,659 Total Output Btuh 37,200 0 4,247 0 Total Output Tons 3 1 1,135 1,140 Total Output Btuh/s ft 22.8 Total Output s ft/Ton 5261 34,128 41,133 Air System CFM perSystem 1,200 HVAC EQUIPMENT SELECTION Airflow cfm 1,200 Trane 5 Ton 30,771 4,947 80 Airflow cfm/s ft 0.74 Airflow cfm/Ton) 387.1 Outside Air (%) 27.2 % Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 30,771 4,947 80 Jan 1 AM Outside Air (cfm/sgft) 0.20 Note: values above given at ARI conditions Aug 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF Outside Air 326 cfm 71 OF 59 OF 110 OF 110 IF • T Heating Coil Supply Fan 1,200 cfm 109 OF ROOM 72 OF COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak 112/78IF Outside Air 326 cfm 77 / 66 OF 86/70°F 62/61 OF 62/61 OF I I Cooling Coil Supply Fan 153161 'IF 1,200 cfm - 59.5 % ROOM 76 !Cis O ZONE LOAD SUMMARY Project Name Custom Residence -The Madison Club Date 5/3/2019 System Name HVAC Zone 3 Floor Area 2,695 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Master 1.0 270 Aug 3 PM 1,924 28,718 5,996 488 32, 363 Kitchen/Utility 1.0 242 Aug 3 PM 867 17,551 5,427 265 22,238 TOTALS 0 01 0 512 Aug 3 PM 46,268 11, 423 54,601 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Custom Residence -The Madison Club Date 5/3/2019 System Name Floor Area HVAC Zone 1 1,888 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Office 1.0 167 Aug 3 PM 951 18,379 3,660 330 21,154 Bedroom 2 1.0 119 Aug 3 PM 619 12,353 2,755 239 15, 207 Bar 1.0 69 Aug 3 PM 364 7,226 11507 107 7,581 TOTALS 0 0 0 354 Aug 3 PM j 37,957 T 922 43,942 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 2 Date 5/3/2019 Floor Area 2,034 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Living/Foyer 1.0 333 Aug 3 PM 2,764 40,386 7,009 717 44, 231 Flex 1.0 122 Aug 3 PM 886 13,534 2,676 184 13,151 TOTALS1 0 0 0 454 Aug 3 PM 53, 920 9,685 57,382 (BLOCK LOAD ZONE LOAD SUMMARY Project Name Custom Residence -The Madison Club Date 5/3/2019 System Name HVAC Zone 4 Floor Area 2,199 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heatin OA CFM Peak Hr CFM Sensible Latent CFM Sensible Rec Room 1-0 191 Aug 3 PM 1,175 20,985 4,201 376 24,130 Bedroom 3/Hall 1.0 130 Aug 3 PM 684 12,909 3,006 255 16,345 Bedroom 4 1.0 78 Aug 3 PM 312 6,603 1,803 96 7,565 TOTALS 0 0 0 398 Aug 3 PM 1 40,4981 9,0101 48,039 (BLOCK LOAD) ZONE LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 System Name Floor Area HVAC Zone 5 1,631 ZONE LOAD SUMMARY ZONAL SYSTEM COOLING PEAK HEATING PEAK ZONE NAME SYSTEM NAME Mult. CFM Sensible Latent Heating OA CFM Peak Hr CFM Sensible Latent CFM Sensible Guest 1.0 326 Aug 3 PM 1,447 32,166 7,167 587 39,163 TOTALS 1 0 0 0 326 Aug 3 PM 32,166 7,167 39,163 (BLOCK LOAD ROOM LOAD SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 3 ROOM LOAD SUMMARY Date 5/3/2019 Floor Area 2,695 ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Master Master Bedroom 1 1,924 18,363 1,741 1,924 18,363 1,741 488 19,131 Kitchen/Utility Kitchen & Utility 1 867 8,275 1,615 867 8,275 1,615 265 10,386 PAGE TOTAL TOTAL" I ` Total includes ventilation load for zonal 2,791 26,638 3,3561 752 29, 577 2,791 26,6381 3,3561 752 29.5171 ROOM LOAD SUMMARY Project Name Custom Residence -The Madison Club Date 5/3/2019 Floor Area 1,888 System Name HVAC Zone 1 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Office Office 1 951 11,996 1,037 951 11,996 1.037 330 12,999 Bedroom 2 Bedroom 2 1 619 7,806 887 619 7,806 887 239 9,398 Bar Bar 1 3641 4,598 427 364 4,598 427 107 4,223 PAGE TOTAL 1,934 24,400 2,35.1 676 26,619 TOTAL * 1,934 24, 400 2, 351 676 26, 619 Total includes ventilation load for zonal systems. ROOM LOAD SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 2 ROOM LOAD SUMMARY Date 5/3/2019 Floor Area 2,034 ROOM COOLING PEAK I COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible Living/Foyer Living/Foyer 1 2,764 27,647 1,774 2,764 27,647 1,774 717 27,954 Flex Flex 1 886 8,868 7581 8861 8,8681 758 184 7,188 Total zonal PAGE TOTAL TOTAL* 3,650 36,515 2,5331 907 35,142 3.6501 36,5151 2,5331 901 35,142 ROOM LOAD SUMMARY Project Name Custom Residence -The Madison Club System Name HVAC Zone 4 ROOM LOAD SUMMARY Date 5/3/2019 Floor Area 2,199 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible I Latent CFM Sensible Latent CFM I Sensible Rec Room Rec./Media 1 1,175 13,660 1,190 1,175 13,660 1,190 376 14,770 Bedroom 3/Hall Bedroom 3 1 684 7,948 967 684 7,948 967 255 10,005 Bedroom 4 Bedroom 4 1 3121 3,627 580 312 3,627 580 96 3,763 PAGE TOTAL TOTAL* j ' Total includes ventilation load for zonal 2,171 25,2351 Z 738 727 28, 538 2,171 25, 235 2,7381 727 28,5381 ROOM LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 System Name Floor Area HVAC Zone 5 1,631 ROOM LOAD SUMMARY Zone Name I Room Name Guest I Guest Total includes ventilation load for ROOM COOLING PEAK Mult. CFM i Sensible I Latent 1 1,4471 19,6691 2,031 PAGE TOTAL TOTAL* COIL COOLING PEAK COIL HTG. PEAK CFM Sensible I Latent CFM I Sensible 1,4471 19,6691 2,0311 5871 23,194 1,447 19, 669 1 2.0311 587 23,194 1,447 19.669 2.031 587 23.i94 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Floor Area 1,398.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Pitched Roof wl R-13 1,398.0 0.0236 46 1,515 R-21 Wall (W.21.2x8.16) 1,023.1 0.0690 46 3,247 Fixed .39131 80.0 0.3900 46 1,435 Casement _51..26 18.9 0.5000 46 435 Patio Door.39L32 264.0 0.3900 46 4.736 Slab -On -Grade perim = 125, 0 0.7300 46 4,198 "R-0 Interior Wall 120.0 0.3560 0 0 X X X X Page Total / 60 ] X AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,398 X Area another room 11.60 X 0.270 Heighl ACH 15,565 = 3,566 TOTAL HOURLY HEAT LOSS FOR ROOM 19,131 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen & Utility Floor Area 1,297.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F 461 = c = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Filched Roof w/l- 13 1,297.0 0.0236 1,405 R-21 Well (W.21.24.16) 288.7 0.0690 46 916 Casement .51..26 24.3 0.5000 46 559 Slab -an -Grade perim = 125.0 0.7300 46 4,198 'R-0 Interior Well 380.0 0.3560 0 0 'R-13 Wall 300.0 0.1020 0 0 through an interior surface X 1,297 X Area Items shown wjth an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction Page Total / 60 ] X AT another room 11.20 X 0.279 Height ACH 7,078 = 3,308 TOTAL HOURLY HEAT LOSS FOR ROOM 10,386 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Floor Area 833.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to L Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4T °F = = = = = c = = = = = = = = = = = = = = = = = = = = = = _ 4fi Btu/hr R-38 Pitched Roof w1 R-13 833.0 0.0236 46 902 R•21 Wall {W.21.2x6.16] 541.8 0.0690 46 1,720 Patio poor .391..32 226.6 0.3900 46 4,065 Fixed .39131 78.0 0.3900 46 1,399 Casement .51..26 14.6 0.5000 46 336 Slab -On -Grade perim = 73.0 0.7300 46 2,451 •R-0 Interior Well 520.0 0.3560 0 0 another room 12.00 X 0.261 Height ACH Page Total / 60 ] X AT Items shown with an asterisk (") denote conduction Infiltration-[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 8331 X Arr:a 10,874 = 2,125 TOTAL HOURLY HEAT LOSS FOR ROOM 12,999 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Floor Area 712.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F _ = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Pitched Roof w/R-13 712.0 00236 46 771 R-21 Wall (W.21.2x6.16) 598.8 0.0690 46 7.901 Casement .5126 16.2 0.5000 46 373 Patio Door. 391.32 120.0 0.3900 46 2,153 Slab -On -Grade perim = 71.0 0.7300 46 2,384 *R-0 Interior Waft 480.0 0.3560 0 0 Items shown with an asterisk (*) denote conduction Infiltration[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 712 X Area another room 10.00 X 0.313 Height ACH Page Total / 60 J X AT 7,582 = 1,Si6 TOTAL HOURLY HEAT LOSS FOR ROOM 9,398 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bar Floor Area 343.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4T OF = = _ = = = = = = = = = = = = = = = = = = = = = = = = _ 46 Btu/hr R-38 Pitched Roof w/ R-13 343.0 0.0236 46 372 R-21 Wall (W21.2x6.16) 12.5 0.0690 46 40 Fixed .39131 137.5 0.3900 46 2,467 Slab -On -Grade perim = 14.0 0.7300 46 470 "R-0 Interior Wall 540.0 0.3560 0 0 X Page Total / 60 J X AT Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 343 X Area another room 12.00 X 0.261 Height ACH 3,348 = 875 TOTAL HOURLY HEAT LOSS FOR ROOM 4,223 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Foyer Floor Area 1,425.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 223 AT OF = = c = = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 twitched Roof w1 R-13 1,425.0 0.0236 0.0690 46 46 1,544 R-21 Waft (W.21.2x6.16) 129.3 277.2 410 Fixed .391..31 0.3900 46 4,973 Custom Entry.921, 59 69.3 0.9200 46 2,933 Patio Door.391.32 572.0 0.3900 46 10.262 Slab -On -Grade perim = 125.0 0.7300 46 4.198 'R-0 Interior Wall 875.0 0.3560 0 0 'R-13 Walt 300.0 0.1020 0 0 Items shown with an aster:sk (*) denote conduction Infiltration:[ E1 J X 1.064 Sd1C-.0L1lG Air Sensible Fraction through an interior surface X 1,425 X Area another room 14.00 X 0 Height AGH Page Total / 60 J X � AT 24.319 = 3,635 27,954 TOTAL HOURLY HEAT LOSS FOR ROOM ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Flex Floor Area 609.00 ft2 Indoor Dry Bulb Temperature 72 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value 0.0236 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F c = = c = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Pitched Roof w/R-13 609.0 43.4 46 660 R-21 Wall (W.21.2x6.16) 0.0690 46 138 Patio Door.391..32 226.6 0.3900 46 4,065 Slab -On -Grade perim = 23.0 0.7300 46 772 *R-0 Interior Wall 635.0 0.3560 0 0 Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 609 X Area another room 12.00 X 0.261 Height ACH Page Total / 60 J X AT 5,635 = 1,553 TOTAL HOURLY HEAT LOSS FOR ROOM 7,188 ROOM HEATING PEAK LOADS Project Name Date Custom Residence -The Madison Club 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Rec./Media Floor Area 956.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X _ to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4T OF = c = = _ = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Pitched Roof w/R-13 956.0 0.0236 46 1.036 R-21 Waif (W.21.2x6.16) 306.0 0.0690 46 971 Casement .5/.26 132.0 0.5000 46 3,036 Patio Door .391..32 264.0 0.3900 46 4,736 Slab -On -Grade perim = 76.0 0.7300 46 2,552 'R-0 Interior Wall 280.0 0.3560 0 0 Page Total / 60 J X AT Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X L 1.064 Schedule Air Sensible Fraction through an interior surface X 956 X Area another room 12.00 X 0.261 Heigh[ ACH 12,331 2,439 TOTAL HOURLY HEAT LOSS FOR ROOM 14,770 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 Floor Area 777.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT OF = = = c = = = = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Pitched Roof w/ R-13 777.0 0.0236 46 642 R-21 Wall (W 21.2x6.16) 645.5 0.0690 46 2,049 Casement .51..26 95.5 0.5000 46 2,197 Wood Door 24.0 0.5000 46 552 Slab -an -Grade perim = 71.0 0.7300 46 2,384 *R-0 Inferior Wall 330.0 0.3560 0 0 another room 10.00 X 0.313� Height ACH Items shown with an asterisk (*) denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 777 X Area Page Total / 60 X AT 8.023 TOTAL HOURLY HEAT LOSS FOR ROOM 10,005 ROOM HEATING PEAK LOADS Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Time of Peak Jan 1 AM Floor Area 466.00 ft2 Outdoor Dry Bulb Temperature 26 °F Indoor Dry Bulb Temperature 72 OF Conduction Area R-38 Pitched Roof w/R-13 466.0 X R-21 Wall (W.21.2x6 16) 418.3 X Swinging Door .51126 5.4 X Casement .5/. 26 6.3 X Slab -On -Grade perim = 14.0 X *R-0 Interior Wall 370.0 X X X X X X X X X X X X X X X X X X X X X X X X X X Items shown with an asterisk (*) denote conduction through an interior surface to another room U-Value AT °F X 46 = X 46 = X 46 = X 46 = X 46 = X 0 = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = X = Page Total Btu/hr 505 1,328 127 145 470 0 1 2,5741 Infiltration:[ l 1.00 X 1.064 X 466 X 10.00 X 0.313 / 60 J X , 461 = Schedule Air Sensible Area Ceiling Height ACH i Fraction 1,189 TOTAL HOURLY HEAT LOSS FOR ROOM 3.763 ROOM HEATING PEAK LOADS Project Name Custom Residence -The Madison Club Date 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Floor Area 1,631.00 ft2 Indoor Dry Bulb Temperature 72 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X to Ceiling U-Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT °F = = = c = = _ = = = = = = = = = = = = = = = = = = = = = = = 46 Btu/hr R-38 Pitched Roof w/ R-13 1,631,0 0.0236 46 1,767 R-21 Wad (W.21.2x6.16) 1,687.7 0.0690 46 5,357 Patio Door .391.32 116.3 0.3900 46 2., 086 Swinging Door.511,,26 24.0 0.5100 46 563 Casement .5/.26 134.0 0.5000 46 3,082 Slab -On -Grade perim = 184.0 0.7300 46 6,179 .R-0 Interior Wall 5.0 0.3560 0 0 through an interior surface X 1,631 X Area Items shown with an asterisk (") denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 12.00 X 0.261 Height ACH Page Total / 60 ] X! AT 19.034 _ a. r60 TOTAL HOURLY HEAT LOSS FOR ROOM 23,194 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Master Bedroom Outdoor Dry Bulb Temperature 112 OF Floor Area 1,398.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Pitched Roof wI R-13 (1/10 1,398.0 X 0.0236 X 56.0 = 1,844 R-21 Wall (W21.2x6.16) (N) 561.1 X 0.0690 X 23.0 = 890 R-21 Wall (W.21.2x6.16) (E) 45.0 X 0.0690 X 33.0 = 102 R-21 Wall (W..21.2x6.16) (S) 210.0 X 0.0690 X 26.0 = 377 R-21 Wall (W.21.2x6.16) (Vl9 207.0 X 0.0690 X 33.0 = 471 'R 0 Inferior Wall 120.0 X 03560 X 0.0 = 0 X X = X X = X X = Page Total 3, 685 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 3X5 (N) 0.0 X 19.3 + 15.0 X 19.3 = 290 3X5 (N) 0.0 X 19.3 + 15.0 X 19.3 = 290 2.5X15 (N) 0.0 X 19.6 + 6.3 X 19.6 = 124 2.5X10 (N) 0.0 X 19.3 + 25.0 X 19.3 = 483 2.5X70 (N) 0.0 X 19.3 + 25.0 X 19.3 = 483 2.5X2, 5 (N) 0.0 X 19.6 + 6.3 X 19.6 = 124 2.5X2.5 (N) 0.0 X 19.6 + 6.3 X 19.6 = 124 6Xi 1 (S) 66.0 X 19.7 + 0.0 X 19.7 = 1,299 18X11 (Vlo 113.4 X 19.7 + 84.6 X 38.7 = 5,503 Page Total 8,79 Internal Gain Btu/hr Occupants 4.2 Occupants X 245 Btuh/occ. _EA ui E ment 1,398 Floor Area X 0.50 w/sgft W Infiltration: 1.064 X 0.88 X 75.25 X 36 2,548 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 18,363 Latent Gain Btu/hr Occupants 4.2 Occupants X F_ 155 Btuh/occ. _ 650 Infiltration: 4,771 X 0.88 X 7525 X 000344 = 1,091 Air Latent CFM ELA 4W TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 650 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Kitchen & Utility Outdoor Dry Bulb Temperature 112 OF Floor Area 1,297.00 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Pitched Roof w1 R-13 W 1,297.0 X 0. 0236 X 56.0 = 1,711 R-21 Well (W.21.2x6.16) (N) 145.7 X 0.0690 X 23.0 = 231 R-21 Wall (W,21.2x6.16) 143.0 X 0.0690 X 33.0 = 326 'R-0 Interior Wall 380.0 X 0.3560 X 0.0 = 0 'R-13 Wall 300.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total Z267 Items shown with an asterisk (") denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 4X4.5 (N) 0.0 X 19.6 + 18.0 X 19.6 = 354 4X4.5 (N) 0.0 X 19.6 + 6.3 X 19.6 = 124 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 477 Internal Gain Btu/hr Occupants X 245 Btuh/occ. Occupants LL12 = 953E ui ment Floor Area X 0.50 w/sgft = 2,213 Infiltration: 1.064 X 0.88 X 69.82 X 36 = 2,364 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,275 Gain Btu/hr _Latent Occupants 39 Occupants X 155� Btuh/occ. = 603 Infiltration: 4,771 X 0.88 X 69.82� X 0.00344 Air Latent CFM ELA 11N TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 603 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club i 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Office Outdoor Dry Bulb Temperature 112 OF Floor Area 833.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R•38 Pitched Roof w1 R-13 (W) 833.0 X 0.0236 X 56.0 = 1,099 R-21 Wall (W 21.2x6.16) (N) 6.7 X 0.0690 X 23.0 = 11 R-21 Walt (W.21.2x6.16) (E) 207.7 X 0.0690 X 33.0 = 473 R-21 Wall (W 21.2x6.16) (S) 287.4 X 0.0690 X 26.0 = 516 R-21 Wall (W.21.2x6.16) W 40.0 X 0.0690 X 33.0 = 91 "R-0 Inferior Wall 520.0 X 0.3560 X 0.0 = 0 X X = X X X X - Page Total 2,189 Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10.3X11 (N) 0.0 X 19.7 + 113.3 X 19.7 = 2,229 i 0.3X11 (E) 113.3 X 19.7 + 0.0 X 38.7 ❑ 2,229 6X11 (S) 0.0 X 19.3 + 66.0 X 19.4 ❑ 1,279 2.7X2.7 (S) 7.3 X 19.6 + 0.0 X 19.7 = 143 3X4 (S) 12.0 X 19.3 + 0.0 X 19.4 = 232 2.7X2.7 (S) 7.3 X 19.6 + 0.0 X 19.7 = 143 X + X = X + X = X + X = Page Total 6,256 Internal Gain Btu/hr Occupants _1 2.5 Occupants X 245 gtuh/occ. = Equipment 833 Floor Area X 0.50 w/sgft =L:1 Infiltration: 1.064 X 0.88� X 44.84 X 36 = 1.518 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 11,996 Latent Gain Btu/hr Occupants 2.5 Occupants X 155 gtuh/occ. = 387 Infiltration: 4,771 X F 088 X 44.84 X 0.00344] = 650 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 387 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 2 Outdoor Dry Bulb Temperature 112 OF Floor Area 712.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor D Bulb Temperature 76 OF 1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Pitched Root wl R-13 (W) 712.0 X 0.0236 X 56.0 = 939 R-21 Walt (W 21.2x6.16) (N) 95.0 X 0.0690 X 23.0 = 151 R-21 Wall (W.21.2x6.16) (E) 80.0 X 0.0690 X 33.0 = 182 R-21 Wall (W.21.2x6.16) (S) 303.8 X 0.0690 X 26.0 = 545 R-21 Wall (W.21.2x6.16) (W) 120.0 X 0.0690 X 33.0 = 273 'R-0 Interior Wall 480.0 X 0.3560 X 0.0 = 0 X X = X X = X X = Page Total 2,090 Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 2X2.7 (S) 0.0 X 19.6 + 5.4 X 19.7 = 106 4X2.7 (S) 0.0 X 19.6 + 10.8 X 19.7 = 213 12XIO (W) 120.0 X 19.7 + 0.0 X 38.7 = 2,361 X + X - X + X - X + X - X + X - X + X = X + _ X = Page Total 2,680 Internal Gain Btu/hr Occupants 21 Occupants X 245 Btuh/occ. = 523 E ui menf 712 Floor Area X 0.501 w/sgft Infiltration: 1.064 X 0.88 X 38.33 X 36 = 1,298 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,806 Latent Gain Btu/hr Occupants 2.1 Occupants X 155 Btuh/occ. - 331 Infiltration: 4,771 X 0.881 X 38.33 X 0.00344 = 555 Air Latent CFM FLA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 331 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bar Outdoor Dry Bulb Temperature 112 OF Floor Area 343.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD� Btu/hr R-38 Pitched Roof w1 R-13 (W) 343.0 X 0.0236 X 56.0 = 452 R-21 Wall (W.21.2x6.16) (E) 12.5 X 0.0690 X 33.0 = 28 *R--0 Interior Wall 540.0 X 0.3560 X 0.0 = a X X = X X = X X = X X = X X = X X = Page Total 481 Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 12.5X11 (E) 137.5 X 19.3 + 0.0 X 37.7 = 2,654 X + X = X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 2,654 Internal Gain Btu/hr Occupants 1.0 Occupants X 245 Btuh/occ. — 252 Equipment 343 Floor Area X 0.501 w/sgft Infiltration: 1.064 X 0.88 X 18.46 X 36 = 625 Air Sens! We CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 4,598 Latent Gain Btu/hr Occupants 1.0 Occupants X 1551 Btuh/occ. = 159 Infiltration: 4,771 X o.88 X 18.46! X 0 00344 - 268 Air Latent GFM ELA iW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 159 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Living/Foyer Outdoor Dry Bulb Temperature 112 OF Floor Area 1,425.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF1 Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Pitched Roof wI R-13 (Kq 1,425.0 X 0.0236 X 56.0 = 1.879 R-21 Wall (W21.2x6.16) (E) 69.3 X 0.0690 X 33.0 = 158 R-21 Wall (W.21.2x6.16) (W) 60.0 X 0.0690 X 33.0 = 137 R 0 Interior Wall 875.0 X 0.3560 X 0.0 = 0 'R 13 Wall 300.0 X 0.1020 X 0.0 = 0 X X = X X = X X = X X = Page Total 2,174 Items shown with an asterisk (*) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 12.6X11 (E) 138.6 X 19.3 + 0.0 X 37.7 = Z675 6.3X11 (E) 69.3 X 40.3 + 0.0 X 75.3 = 2,792 12.6X71 (E) 138.6 X 19.3 + 0.0 X 37.7 = 2,675 44X13 W 572.0 X 19.7 + 0.0 X 38.7 = 11,254 X + X = X + X = X + X = X + X = X + X. Page Total 19.397 Internal Gain Btu/hr Occupants Occupants X 245 N142 Btuh/occ. = 1,047 E ui ment Floor Area X 0.50 w/sgft Infiltration: 1.064 X 0.88 X 76.71I X 36 Air Sensible _ CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 27,647 Latent Gain Btu/hr Occupants 4,3 Occupants X � 155 Btuh/occ. = 663 Infiltration: 4,771 X 0.88 X 76.71 X 0.00344 = 7.992 Air Latent CFM FLA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 663 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Flex Outdoor Dry Bulb Temperature 112 OF Floor Area 609.00 ftZ Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-36 Pitched Roof wI R-13 (WJ 609.0 X 0.0236 X 56.0 = 803 R-21 Wall (W.21.24.16) (E) 24.7 X 0.0690 X 33.0 = 56 R-21 Wall (W.21.2x6.16) (S) 18.7 X 0.0690 X 26.0 = 34 'R-0 Interior Wall 635.0 X 0.3560 X 0.0 = 0 X X = X X = X X = X X = X X = Page Total 893 Items shown with an asterisk (*) denote conduction through an interior surface to another room 1 Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10.3X11 (E) 64.9 X 19.7 + 484 X 38.7 = 3,149 10.3X11 (S) 113.3 X 19.7 + 0.0 X 19.7 = 2,229 X + X — X + X = X + X = X + X = X + X = X + X = X + X = Page Total-37 Internal Gain Btu/hr Occupants 1.8 Occupants X 245. Btuh/occ. = 448 Equipment 609 Floor Area X 0.50I. w/sgft = 1,039 Infiltration: 1.064 X 0.88 X 32.78 X 36 = f,110 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 8,868 Latent Gain Btu/hr _ Occupants 1•8 Occupants X � 1551 gtuh/occ. — 283 Infiltration: 4,771 X 0.88 X 32.78 X 0.00344 = 475 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 283 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 1 51312019 ROOM INFORMATION DESIGN CONDITIONS Room Name Rec./Media Outdoor Dry Bulb Temperature 112 OF Floor Area 956.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor D Bulb Temperature 76 6F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R 38 Pitched Roof wl R-13 (W) 956 0 X 0.0236 X 56.0 = 1,261 R-21 Wall (W.21,2x6.16) (N) 192.0 X 0.0690 X 23.0 = 305 R-21 Wall (W.21.2x6.16) (S) 60.0 X 0.0690 X 26.0 = 108 R-21 Wall (W.21.2x6,16) 54.0 X 0.0690 X 33.0 = 123 'R--0 Interior Wall 280.0 X 0.3560 X 0.0 = ❑ X X = X X = i X X X X _ Page Total 1. 796 Items shown with an asterisk (') denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 6X11 (N) 0.0 X 19.6 + 66.0 X 19.6 = 1,297 6X11 (N) 0.0 X 19.6 + 66.0 X 19.6 = 1,297 24X11 (S) 264.0 X 19.7 + 0.0 X 19.7 = 5,194 X + X = X + X = X + X = X + X = X + X = X + X = _ Page Total 7..78 Internal Gain Btu/hr Occupants 2.9 Occupants X 245 Btuh/occ. _ 703 Equipment 956 Floor Area X 0.50 w/sgft 1,631 Infiltration: 1.064 X 0.88 X 51.46 X 36 = 1,742 Air Sensible CFM ELA 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 13,660 Latent Gain Btu/hr Occupants 2.9 Occupants X 155� Btuh/occ. .. 445 Infiltration: 4,771 X 0.88 X 51.46 X 0.00344 = 746 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 445 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 3 Outdoor Dry Bulb Temperature 112 OF Floor Area 777.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Pitched Roof w/ R-13 (W) 777.0 X 0.0236 X 56.0 = 1,025 R-21 Wall (W 21.2x6.16) (N) 12.0 X 0.0690 X 23.0 = 19 R-21 Wall (W 21.2x6.16) (E) 256.0 X 0.0690 X 33.0 = 583 Wood Door (E) 24.0 X 0.5000 X 33.0 = 396 R-21 Wall (W 21.2x6.16) (S) 262.5 X 0,0690 X 26.0 = 471 R-21 Wall (W.21.2x6.16) (W) 115.0 X 0.0690 X 33.0 = 262 'R-0 lnivior Walf 330.0 X 0.3560 X 0.0 = 0 X X = X L X = Page Total 2.755 Items shown with an asterisk (*) denote conduction through an interior surface to another room 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 6X8 (N) 0.0 X 19.6 + 48.0 X 19.6 = 943 2.5X3 (S) 0.0 X 19.6 + 7.5 X 19.7 = 148 8X5 (S) 0.0 X 19.6 + 40.0 X 19.7 = 788 X + X = X + X = X + X = X + X = X + X = X + X = Page Total 1,879 Internal Gain Btu/hr Occupants 2.3 Occupants X 245 Btuh/occ. = 571 Equipment 777 Floor Area X 0.50I w/sgft Infiltration: 1.064 X 0.88 X 41.82 X 36 = 1,416 Air Sensible CFM Et.A 4T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,948 Latent Gain Btu/hr Occupants 12.3 Occupants X 155 Btuh/occ. = 361 Infiltration: 4,771 X 0.88 X 41.82 X 0.00344 = 606 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 361 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Bedroom 4 Outdoor Dry Bulb Temperature 112 OF Floor Area 466.00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 °F Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-38 Pitched Roof wl R-13 466.0 X 0.0236 X 56.0 = 615 R-21 Wall (W.21.2x6.16) (N) 228.3 X 0.0690 X 23.0 = 362 R-21 Wag (W.21.2x6.16) (E) 190.0 X 0.0690 X 33.0 = 433 'R-0 Interior Wall 370.0 x 0.3560 X 0.0 = 0 x x = x x = x x = x x = x x = Page Total 7,470 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 8X5 (N) 0.0 x 19.8 + 5.4 X 19.8 = 107 2.5X3 (N) 0.0 X 19.6 + 6.3 X 19.6 = 124 X + X = X + X = X + X = X + X = X + X = X + X = X + X = Page Total 231 Internal Gain Btu/hr Occupants 1 4 Occupants X 2451 Btuh/occ. = 343 Equipment 466 Floor Area X 0.50I w/sgft = 795 Infiltration: 1.064 x 0.88 x 25.08 x 36 = 849 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3,627 Latent Gain Btu/hr Occupants 1 4 Occupants X 155 Btuh/occ. = 217 Infiltration: 4,771 X 0.88 X 25.08 X 0.00344 = 364 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 217 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Custom Residence -The Madison Club 5/3/2019 ROOM INFORMATION DESIGN CONDITIONS Room Name Guest Outdoor Dry Bulb Temperature 112 OF Floor Area 1, 63 1. 00 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 76 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R 38 Pitched Roof wl R-13 1,631.0 X 0,0236 X 56.0 = 2,151 R-21 Well (W.21.2x6.16) (N) 418.0 X 0.0690 X 23.0 = 663 R-21 Wall (W.21. 2x6.16) (E) 354.8 X 0,0690 X 33.0 = 808 R-21 Wall (W 21.2x6.16) (S) 440.0 X 0.0690 X 26.0 = 789 R-21 Wall (W21.2x6.16) 474.9 X a0690 X 33.0 = 1,081 R-0 Interior Wall 5.0 X a3560 X 0.0 = 0 X X = X X = X X = Page Total 5.493 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr 10X11 (N) 0.0 X 19.7 + 110.0 X 19.7 = 2,164 3X8 (E) 0.0 X 19.8 + 24.0 X 35.3 = 847 SX8 (E) 0.0 X 19.6 + 64.0 X 35.1 = 2,245 6X2.7 (E) 0.0 X 19.6 + 16.2 X 35.1 = 566 8X5 (S) 0.0 X 19.6 + 40.0 X 19.7 = 788 2.5X3 (W) 0.0 X 19.6 + 7.5 X 35.1 = 263 3.5X4.5 (M 0.0 X 19.6 + 6.3 X 35.11 = 221 15X11 (W) 6.3 X 19.7 + 0.0 X 38.7 = 124 X + X = Page Total 7,221 Internal Gain Btu/hr Occupants 4.9 Occupants X 245 Btuh/occ. = 1.1.99 Equipment 1,631 Floor Area X 0.50 w/sgft = 2,783 Infiltration: 1.064 X 0.88 X 87.79 X 36 = 2,972 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,669 Latent Gain Btu/hr Occupants 4 9 Occupants X 1551 Btuh/occ. = 758 Infiltration: 4,771 X 0.88 X 87 791 X 0.00344 Air Latent CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 758 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x CF1 R-PRF-01 Page 1 of 16 GENERAL INFORMATION 01 Project Name Madison Lot 18B 02 Calculation Description Title 24 Analysis 03 Project Location Lot 18-13, 52355 Meriwether 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 90 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft) 10447 15 Number of Zones 11 16 Slab Area (ft2) 10447 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 27.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.51 5.09 -2.58 -102.8% Space Cooling 72.33 69.68 2.65 3.7% IAQ Ventilation 0.69 0.69 0.00 0.0% Water Heating j 1.57 1.36 0.21 13.4% Photovoltaic 0.00 0.00 -----Compliance Enet"CATY gy Tot 10 76.82 0.28 0.4% REVIEWED FUH CODE COMPLIANCE DATE S 14 ' 1018Y t'aroes Zo 11 ' o q y � Registration Number: 219-P010033172B-000.000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2019-05-03 11:13:38 Report Version - CF1 R-01162019-1149 RECEIVED MAY 062019 M*UWA CaICERTS inc. DESIGN -03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Description: Title 24 Analysis Calculation Date/Time: 11:06, Fri, May 03, 2019 Input File Name: Madison Lot 18B-Radford-19.ribd16x CF1 R-PRF-01 Page 2 of 16 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 44.8 44.7 0.0 44.7 ❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. ❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. [Notes:xcess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 219-PO10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 [a] AIza;a:7;Eli I Page 3 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Madison Lot 18B 10447 1 6 11 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Master Conditioned HVAC Zone 31 1398 11.6 DHW Sys 1 n/a Kitchen/Utility Conditioned HVAC Zone 31 1297 11.2 DHW Sys 1 n/a Office Conditioned HVAC Zone 12 833 12 DHW Sys 1 n/a Bedroom 2 Conditioned HVAC Zone 12 712 10 DHW Sys 1 n/a Bar Conditioned HVAC Zone 12 343 12 DHW Sys 1 n/a Living/Foyer Conditioned HVAC Zone 23 1425 14 DHW Sys 1 n/a Flex Conditioned HVAC Zone 23 609 12 DHW Sys 1 n/a Rec Room Conditioned HVAC Zone 44 956 12 DHW Sys 1 n/a Bedroom 3/Hall Conditioned HVAC Zone 44 777 10 DHW Sys 1 n/a Bedroom 4 Conditioned HVAC Zone 44 466 10 DHW Sys 1 n/a Guest Conditioned HVAC Zone 55 1631 12 DHW Sys 1 n/a Registration Number: 219-Po10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 4 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) N Wall Master R-21 Wall (W.21.2x6.16) 0 Right 660 98.9 90 E Wall Master R-21 Wall (W.21.2x6.16) 90 Front 45 0 90 S Wall Master R-21 Wall (W.21.2x6.16) 180 Left 276 66 90 W Wall Master R-21 Wall (W.21.2x6.16) 270 Back 405 198 90 Interior Surface Master»Kitchen/Utility R-0 Interior Wall n/a n/a 120 0 n/a Roof -pitched Master R-38 Pitched Roof w/ R-1 n/a n/a 1398 n/a n/a N Wall 2 Kitchen/Utility R-21 Wall (W.21.2x6.16) 0 Right 170 24.3 90 W Wall 2 Kitchen/Utility R-21 Wall (W.21.2x6.16) 270 Back 143 0 90 Interior Surface 2 Kitchen/Utility»Flex R-0 Interior Wall n/a n/a 260 0 n/a Interior Surface 3 Kitchen/Utility»Master R-0 Interior Wall n/a n/a 120 0 n/a Interior Surface 4 Kitchen/Utility»Living/Foyer R-13 Wall n/a n/a 300 0 n/a Roof -pitched 2 Kitchen/Utility R-38 Pitched Roof w/ R-1 n/a n/a 1297 n/a n/a N Wall 3 Office R-21 Wall (W.21.2x6.16) 0 Right 120 113.3 90 E Wall 2 Office R-21 Wall (W.21.2x6.16) 90 Front 321 113.3 90 S Wall 2 Office R-21 Wall (W.21.2x6.16) 180 Left 380 92.5946 90 W Wall 3 Office R-21 Wall (W.21.2x6.16) 270 Back 40 0 90 Interior Surface 5 Office»Bar R-0 Interior Wall n/a n/a 200 0 n/a Interior Surface 6 Office»Bedroom 2 R-0 Interior Wall n/a n/a 320 0 n/a Roof -pitched 3 Office R-38 Pitched Roof w/ R-1 n/a n/a 833 n/a n/a N Wall 4 Bedroom 2 R-21 Wall (W.21.2x6.16) 0 Right 95 0 90 E Wall 3 Bedroom 2 R-21 Wall (W.21.2x6.16) 90 Front 80 0 90 S Wall 3 Bedroom 2 R-21 Wall (W.21.24.16) 180 Left 320 16.2 90 W Wall 4 Bedroom 2 R-21 Wall (W.21.2x6.16) 270 Back 240 120 90 Interior Surface 7 Bedroom 2»Living/Foyer R-0 Interior Wall n/a n/a 160 0 n/a Interior Surface 8 Bedroom 2»Office R-0 Interior Wall n/a n/a 320 0 n/a Roof -pitched 4 Bedroom 2 R-38 Pitched Roof w/ R-1 n/a n/a 712 n/a n/a E Wall 4 Bar R-21 Wall (W.21.2x6.16) 90 Front 150 137.5 90 Interior Surface 9 Bar R-0 Interior Wall n/a n/a 500 0 n/a Interior Surface 10 Bar»Office R-0 Interior Wall n/a n/a 200 0 n/a Interior Surface 11 Bar»Living/Foyer R-0 Interior Wall n/a n/a 340 0 n/a Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 5 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 1813-Radford-19.ribdl6x Roof -pitched 5 Bar R-38 Pitched Roof w/ R-1 n/a n/a 343 n/a n/a E Wall 5 Living/Foyer R-21 Wall (W21.2x6.16) 90 Front 415.8 346.522 90 W Wall 5 Living/Foyer R-21 Wall (W.21.2x6.16) 270 Back 632 572 90 Interior Surface 12 Living/Foyer»Bedroom 2 R-0 Interior Wall n/a n/a 160 0 n/a Interior Surface 13 Living/Foyer»Bar R-0 Interior Wall n/a n/a 340 0 n/a Interior Surface 14 Living/Foyer»Kitchen/Utility R-13 Wall n/a n/a 300 0 n/a Interior Surface 15 Living/Foyer»Flex R-0 Interior Wall n/a n/a 375 0 n/a Roof -pitched 6 Living/Foyer R-38 Pitched Roof w/ R-1 n/a n/a 1425 n/a n/a E Wall 6 Flex R-21 Wall (W.21.2x6.16) 90 Front 138 113.3 90 S Wall 4 Flex R-21 Wall (W21.2x6.16) 180 Left 132 113.3 90 Interior Surface 16 Flex»Living/Foyer R-0 Interior Wall n/a n/a 375 0 n/a Interior Surface 17 Flex>>Kitchen/Utility R-0 Interior Wall n/a n/a 260 0 n/a Roof -pitched 7 Flex R-38 Pitched Roof w/ R-1 n/a n/a 609 n/a n/a N Wall 5 Rec Room R-21 Wall (W.21.2x6.16) 0 Right 324 132 90 S Wall 5 Rec Room R-21 Wall (W.21.2x6.16) 180 Left 324 264 90 W Wall 6 Rec Room R-21 Wall (W.21.2x6.16) 270 Back 54 0 90 Interior Surface 18 Rec Room»Bedroom 3/Hall R-0 Interior Wall n/a n/a 120 0 n/a Interior Surface 19 Rec Room»Bedroom 4 R-0 Interior Wall n/a n/a 160 0 n/a Roof -pitched 8 Rec Room R-38 Pitched Roof w/ R-1 n/a n/a 956 n/a n/a N Wall 6 Bedroom 3/Hall R-21 Wall (W.21.2x6.16) 0 Right 60 48 90 E Wall 7 Bedroom 3/Hall R-21 Wall (W.21.2x6.16) 90 Front 280 24 90 S Wall 6 Bedroom 3/Hall R-21 Wall (W.21.2x6.16) 180 Left 310 47.5 90 W Wall 7 Bedroom 3/Hall R-21 Wall (W 21.2x6.16) 270 Back 115 0 90 Interior Surface 20 Bedroom 3/Hall»Bedroom 4 R-0 Interior Wall n/a n/a 210 0 n/a Interior Surface 21 Bedroom 3/Hall»Rec Room R-0 Interior Wall n/a n/a 120 0 n/a Roof -pitched 9 Bedroom 3/Hall R-38 Pitched Roof w/ R-1 n/a n/a 777 n/a n/a N Wall 7 Bedroom 4 R-21 Wall (W.21.2x6.16) 0 Right 240 11.7 90 E Wall 8 Bedroom 4 R-21 Wall (W.21.2x6.16) 90 Front 190 0 90 Interior Surface 22 Bedroom 4—Bedroom 3/Hall R-0 Interior Wall n/a n/a 210 0 n/a Interior Surface 23 Bedroom 4»Rec Room R-0 Interior Wall n/a n/a 160 0 n/a Roof -pitched 10 Bedroom 4 R-38 Pitched Roof w/ R-1 n/a n/a 466 n/a n/a N Wall 8 Guest R-21 Wall (W.21.2x6.16) 0 Right 528 110 90 E Wall 9 Guest R-21 Wall (W 21.2x6.16) 90 Front 459 104.2 90 Registration Number: 219-P010033172B-000-000-0000000-0000 Registration DatefTime: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 6 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x S Wall 7 Guest R-21 Wall (W.21.2x6.16) 180 Left 480 40 90 W Wall 8 Guest R-21 Wall (W.21.2x6.16) 270 Back 495 20.07 90 Interior Surface 24 Guest»Living/Foyer R-0 Interior Wall n/a n/a 5 0 n/a Roof -pitched 11 Guest R-38 Pitched Roof w/ R-1 n/a n/a 1631 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Master Attic RoofMaster Ventilated 3 0.1 0.85 Yes No Attic Kitchen/Utility Attic RoofKitchen/Utility Ventilated 3 0.1 0.85 Yes No Attic Office Attic RoofOffice Ventilated 3 0.1 0.85 Yes No Attic Bedroom 2 Attic RoofBedroom 2 Ventilated 3 0.1 0.85 Yes No Attic Bar Attic RoofBar Ventilated 3 0.1 0.85 Yes No Attic Living/Foyer Attic RoofLiving/Foyer Ventilated 3 0.1 0.85 Yes No Attic Flex Attic RoofFlex Ventilated 3 0.1 0.85 Yes No Attic Rec Room Attic RoofRec Room Ventilated 3 0.1 0.85 Yes No Attic Bedroom 3/Hall Attic RoofBedroom 3/Hall Ventilated 3 0.1 0.85 Yes No Attic Bedroom 4 Attic RoofBedroom 4 Ventilated 3 0.1 0.85 Yes No Attic Guest Attic RoofGuest Ventilated 3 0.1 0.85 Yes No Registration Number: 219-Po10033172B-000-000-0000000-0000 Registration DatefTime: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 7 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier p Area (ft) U-factor SHGC Exterior Shading 3X5 Window N Wall (Right-0) ---- - 1 15.0 0.39 0.31 Insect Screen (default) 3X5 2 Window N Wall (Right-0) 1 15.0 0.39 0.31 Insect Screen (default) 2.5X2.5 Window N Wall (Right-0) 1 6.3 0.50 0.26 Insect Screen (default) 2.5X10 Window N Wall (Right-0) ---- -- 1 25.0 0.39 0.31 Insect Screen (default) 2.5X10 2 Window N Wall (Right-0) -- - 1 25.0 0.39 0.31 Insect Screen (default) 2.5X2.5 2 Window N Wall (Right-0) ---- - 1 6.3 0.50 0.26 Insect Screen (default) 2.5X2.5 3 Window N Wall (Right-0) - ---- 1 6.3 0.50 0.26 Insect Screen (default) 6X11 Window S Wall (Left-180) 6.0 11.0 1 66.0 0.39 0.32 Insect Screen (default) 18X11 Window W Wall (Back-270) 18.0 11.0 1 198.0 0.39 0.32 Insect Screen (default) 4X4.5 Window N Wall 2 (Right-0) ---- - 1 18.0 0.50 0.26 Insect Screen (default) 4X4.5 2 Window N Wall 2 (Right-0) ---- ----- 1 6.3 0.50 0.26 Insect Screen (default) 10.3X11 Window N Wall 3 (Right-0) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 10.3X11 2 Window E Wall 2 (Front-90) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 6X11 2 Window S Wall 2 (Left-180) ---- -- 1 66.0 0.39 0.31 Insect Screen (default) 2.7X2.7 Window S Wall 2 (Left-180) 2.7 2.7 1.001 7.3 0.50 0.26 Insect Screen (default) 3X4 Window S Wall 2 (Left-180) 3.0 4.0 1 12.0 0.39 0.31 Insect Screen (default) 2.7X2.7 2 Window S Wall 2 (Left-180) 2.7 2.7 1.001 7.3 0.50 0.26 Insect Screen (default) 2X2.7 Window S Wall 3 (Left-180) --- -- 1 5.4 0.50 0.26 Insect Screen (default) 4X2.7 Window S Wall 3 (Left-180) ---- -- 1 10.8 0.50 0.26 Insect Screen (default) 12X10 Window W Wall 4 (Back-270) 12.0 10.0 1 1200. 0.39 0.32 Insect Screen (default) 12.5X11 Window E Wall 4 (Front-90) 12.5 11.0 1 137.5 0.39 0.31 Insect Screen (default) 12.6X11 Window E Wall 5 (Front-90) 19.0 11.0 0.663 138.6 0.39 0.31 Insect Screen (default) 6.3X11 Window E Wall 5 (Front-90) 19.0 11.0 0.332 69.4 0.92 0.59 Insect Screen (default) 12.6X11 2 Window E Wall 5 (Front-90) 19.0 11.0 0.663 138.6 0.39 0.31 Insect Screen (default) 44X13 Window W Wall 5 (Back-270) 44.0 13.0 1 572.0 0.39 0.32 Insect Screen (default) 10.3X11 3 Window E Wall 6 (Front-90) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 10.3X11 4 Window S Wall 4 (Left-180) 10.3 11.0 1 113.3 0.39 0.32 Insect Screen (default) 6X11 3 Window N Wall 5 (Right-0) ---- ---- 1 66.0 0.50 1 0.26 Insect Screen (default) 6X11 4 Window N Wall 5 (Right-0) ---- I ---- 1 66.0 0.50 0.26 Insect Screen (default) Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation DatelTime: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 8 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x 24X11 Window S Wall 5 (Left-180) 24.0 11.0 1 264.0 0.39 0.32 Insect Screen (default) 6X8 Window N Wall 6 (Right-0) ---- ---- 1 48.0 0.50 0.26 Insect Screen (default) 2.5X3 Window S Wall 6 (Left-180) ---- ---- 1 7.5 0.50 0.26 Insect Screen (default) 8X5 Window S Wall 6 (Left-180) -- 1 40.0 0.50 0.26 Insect Screen (default) 8X5 2 Window N Wall 7 (Right-0) ---- ---- 1 5.4 0.51 0.26 Insect Screen (default) 2.5X3 2 Window N Wall 7 (Right-0) --- ---- 1 6.3 0.50 0.26 Insect Screen (default) 10X11 Window N Wall 8 (Right-0) 10.0 11.0 1 110.0 0.39 0.32 Insect Screen (default) 3X8 Window E Wall 9 (Front-90) ---- - 1 24.0 0.51 0.26 Insect Screen (default) 8X8 Window E Wall 9 (Front-90) 1 64.0 0.50 0.26 Insect Screen (default) 6X2.7 Window E Wall 9 (Front-90) 1 16.2 0.50 0.26 Insect Screen (default) 8X5 3 Window S Wall 7 (Left-180) ---- - 1 40.0 0.50 0.26 Insect Screen (default) 2.5X3 3 Window W Wall 8 (Back-270) - 1 7.5 1 0.50 0.26 Insect Screen (default) 3.5X4.5 Window W Wall 8 (Back-270) --�T15.0 - - 1 6.3 0.50 0.26 Insect Screen (default) 15X11 Window W Wall 8 (Back-270) 11.0 0.038 6.3 0.39 0.32 Insect Screen (default) OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ftft2) U-factor Door E Wall 7 24.0 0.50 Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 186 Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 9 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up 6X11 4 0.1 4 4 0 1 0 0 0 0 0 0 0 0 18X11 8 0.1 8 8 0 0 0 0 0 0 0 0 0 10.3X11 10 0.1 10 10 0 0 0 0 0 0 0 0 0 10.3X112 18 0.1 18 18 0 0 0 0 0 0 0 0 0 2.7X2.7 3 0.1 3 0 0 0 0 0 0 0 0 0 0 3X4 3 0.1 3 0 0 0 0 0 0 0 0 0 0 2.7X2.7 2 3 0.1 3 0 0 0 0 0 0 0 0 0 0 12X10 14 0.1 14 14 0 0 0 0 0 0 0 0 0 12.5X11 14 0.1 14 14 0 0 0 0 0 0 0 0 0 12.6X11 14 0.1 14 14 0 0 0 0 0 0 0 0 0 6.3X11 14 0.1 14 14 0 0 0 0 0 0 0 0 0 12.6X112 14 0.1 14 14 0 0 0 0 0 0 0 0 0 44X13 22 0.1 22 0 0 0 0 0 0 0 0 0 0 10.3X113 8 0.1 8 8 0 0 0 0 0 0 0 0 0 10.3X114 10 0.1 10 10 0 0 0 0 0 0 0 0 0 24X11 12 0.1 12 12 0 0 0 0 0 0 0 0 0 10X11 4 0.1 4 4 0 0 0 0 0 0 0 0 0 15X11 18 0.1 18 18 0 0 0 0 0 0 0 0 0 Registration Number: 219-P010033172B-000-000-0000000-0000 Registration DatefFime: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Description: Title 24 Analysis Calculation DatefTime: 11:06, Fri, May 03, 2019 Input File Name: Madison Lot 18B-Radford-19.ribdl6x CFI R-PRF-01 Page 10 of 16 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Total Cavity Winter Design Construction Name Surface Type Construction Type Framing R-value U-factor Assembly Layers • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofMaster Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board Ceilings (below Cavity/Frame: R-14.3/2x6 R-38 Pitched Roof w/ R-1 attic) Wood Framed Ceiling 2x6 @ 16 in. O.C. R 38 0.026 Over Ceiling Joists: R-23.7 insul. • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 R-21 Wall (W 21 2x6.16) Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board Cavity/Frame: no insul. /2x4 R-0 Interior Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O.C. none 0 277 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofKitchen/Utility Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Inside Finish: Gypsum Board • Cavity/Frame: R-13/2x4 R-13 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in. O C. R 13 0.092 Other Side Finish: Gypsum Board • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck. Wood Siding/sheathing/decking Attic RoofOffice Attic Roofs Wood Framed Ceiling in O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R- 13 0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedroom 2 Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBar Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofLiving/Foyer Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) Registration Number: 219-P010033172B-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 2019-05-03 11:13:38 Report Version - CF1 R-01162019-1149 HERS Provider: CaICERTS inc. Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 11 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 - Roof Deck: Wood Siding/sheathing/decking Attic RoofFlex Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity/Frame: R-13.0/2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofRec Room Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedroom 3/Hall Attic Roofs Wood Framed Ceiling in. 0 C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofBedroom 4 Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) • Around Roof Joists: R-0.0 insul. • Cavity / Frame: R-13.0 / 2x4 Top Chrd 2x4 Top Chord of Roof Truss @ 24 Roof Deck: Wood Siding/sheathing/decking Attic RoofGuest Attic Roofs Wood Framed Ceiling in. O.C. R 13 0.078 Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab Master 1398 125 None 0.8 No Slab 2 Kitchen/Utility 1297 125 None 0.8 No Slab 3 Office 833 73 None 0.8 No Slab 4 Bedroom 2 712 71 None 0.8 No Slab 5 Bar 343 14 None 0.8 No Slab 6 Living/Foyer 1425 125 None 0.8 No Slab 7 Flex 609 23 None 0.8 No Slab 8 Rec Room 956 76 None 0.8 No Slab 9 Bedroom 3/Hall 777 71 None 0.8 No Slab 10 Bedroom 4 466 14 None 0.8 No Slab 11 Guest 1631 184 None 0.8 No Registration Number: 219-PO10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 12 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Standard DHW Heater 1 (2) 2 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Input Rating / Tank Standby Heater Tank Uniform Energy Pilot / Insulation Loss / First Hour NEEA Heat Pump Tank Location Element Number Volume Factor / Energy Thermal R-value Recovery Rating / Brand / Model / or Ambient Name Type Tank Type of Units (gal) Factor I Efficiency Efficiency (Int/Ext) Eff Flow Rate Other Condition DHW Heater 1 Gas Small 2 0 0.95 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a Instantaneous SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name HVAC Zone 31 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC Zone 12 Other Heating and Cooling System Heating Component 2 Cooling Component 2 HVAC Fan 2 Air Distribution System 2 HVAC Zone 23 Other Heating and Cooling System Heating Component 3 Cooling Component 3 HVAC Fan 3 Air Distribution System 3 HVAC Zone 44 Other Heating and Cooling System Heating Component 4 Cooling Component 4 HVAC Fan 4 Air Distribution System 4 HVAC Zone 55 Other Heating and Cooling System Heating Component 5 Cooling Component 5 HVAC Fan 5 Air Distribution System 5 Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation DatelTime: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 13 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE Heating Component 2 CntrlFurnace 1 80 AFUE Heating Component 3 CntrlFurnace 1 80 AFUE Heating Component 4 CntrlFurnace 1 80 AFUE Heating Component 5 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Efficiency Name System Type Number of Units EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool Cooling Component 2 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 2-hers-cool Cooling Component 3 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 3-hers-cool Cooling Component 4 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 4-hers-cool Cooling Component 5 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 5-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required Cooling Component 2-hers-cool Required 350 Required Required Required Cooling Component 3-hers-cool Required 350 Required Required Required Cooling Component 4-hers-cool Required 350 Required Required Required Cooling Component 5-hers-cool Required 350 Required Required Required Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 CF1 R-PRF-01 Page 14 of 16 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 1-hers-dist Air Distribution System 2 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 2-hers-dist Air Distribution System 3 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 3-hers-dist Air Distribution System 4 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 4-hers-dist Air Distribution System 5 DuctsAttic Specified Lower Leakage 8 Attic None Air Distribution System Target 5-hers-dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 2-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 3-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required Air Distribution System 4-hers-dist Required 60 Not Required Not Required Not Required Not Required Required Air Distribution System 5-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC-FAN SYSTEMS 01 02 03 04 Name Type Fan Power (WattsICFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 05 HVAC Fan 1-hers-fan HVAC Fan 2 Single Speed PSC Furnace Fan 0.5 HVAC Fan 2-hers-fan HVAC Fan 3 Single Speed PSC Furnace Fan 0.5 HVAC Fan 3-hers-fan HVAC Fan 4 Single Speed PSC Furnace Fan 0.5 HVAC Fan 4-hers-fan HVAC Fan 5 Single Speed PSC Furnace Fan 0.5 HVAC Fan 5-hers-fan Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x CF1 R-PRF-01 Page 15 of 16 HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.50 HVAC Fan 2-hers-fan Required 0.50 HVAC Fan 3-hers-fan Required 0.50 HVAC Fan 4-hers-fan Required 0.50 HVAC Fan 5-hers-fan Required 0.50 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 157 0.25 Default 0 Required � CaICERTS, Inc. Registration Number: 219-P010033172B-000-000-0000000-0000 Registration DateMme: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019 Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x CF1 R-PRF-01 Page 16 of 16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature Tim Scott - Company: Signature Date: Scott Design and Title 24, Inc. 2019-05-03 11:13:38 Address: CEA/HERS Certification Identification (If applicable): 77085 Michigan Drive City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature Tim Scott G.yfi�CBi Company: Date Signed: Scott Design and Title 24, Inc. 2019-05-03 11:13:38 Address: License: 77085 Michigan Drive NA City/State/Zip: Phone: Palm Desert, CA 92211 760-200-4780 Digitally signed by CaICERTS This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 219-PO10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Easy to Verify at CaICERTS.com HERS Provider: CaICERTS inc. Report Generated at: 2019-05-03 11:08:43