BRES2019-0038 Title 24L _ BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Custom Residence -The Madison Club
Lot 18-13, 52355 Meriwether
La Quinta, CA 92253
Project Designer:
<
Mark Radford Architecture
z _O m w
2282 Via Cascabel
Escondido, CA
w z
92027
D
iO LU O
�-
(760) 432-0348
g U � p
1
�'
Report Prepared by:
m
L,
Tim Scott
U
Scott Design and Title 24, Inc,
74-818 Velie Way, Suite #8
Palm Desert, CA 92260
(760) 200-4780
Job Number: RECEIVED
MAY 062019
Date: CITY OF LA QUINTA
5/3/2019 DESIGN AND DEVELOPMENT DEPARTMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft com
k-
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R-PRF-01-E Certificate of Compliance 3
Form RMS-1 Residential Measures Summary 19
Form MF-1 R Mandatory Measures Summary 21
HVAC System Heating and Cooling Loads Summary 25
Zone Load Summary 30
Room Load Summary 35
Room Heating Peak Loads 40
Room Cooling Peak Loads 51
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1 R-PRF-01
Project Name: Madison Lot 18B
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:06, Fri, May 03, 2019
Input File Name: Madison Lot 18B-Radford-19.ribd16x
Page 1 of 16
GENERAL INFORMATION
01
Project Name
Madison Lot 18B
02
Calculation Description
Title 24 Analysis
03
Project Location
Lot 18-13, 52355 Meriwether
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
12
Building Type
Project Scope
Single Family
Newly Constructed
11
13
Front Orientation (deg/Cardinal)
Number of Dwelling Units
90
1
14
Total Cond. Floor Area (ft2)
10447
1S
Number of Zones
11
16
Slab Area (ft2)
10447
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
�20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
27.8%
COMPLIANCE RESULTS
01 Building Complies with Computer Performance
02 This building incorporates features that require field testing andlor verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03 This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
ndard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
Space Cooling
IAQ Ventilation
2.51
72.33
0.69
5.09
69.68
0.69
-2.58
2.65
0.00
-102.8%
3.7%
0.0%
Water Heating
1.57
1.36
0.21
13.4%
Photovoltaic Offset
----
000
0.00
----
Compliance Energy Total =
77.10
76.82
0.28
0.4%
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
ENERGY DESIGN RATING
CF1 R-PRF-01
Page 2 of 16
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
44.8 44.7 0.0 44.7
❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALG►e¢n A4.203.1.2.2) and QII verification prerequisite.
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII) %J#
• IAQ mechanical ventilation
Cooling System Verifications:"'°
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verificafions
• --None -- f
Registration Number: Registration DaterTime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
CF1R-PRF-01
Project Name: Madison Lot 18B
Calculation Daterrime:
11:06, Fri, May 03, 2019
Page 3 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Number of Dwelling
Number of Ventilation
Number of Water
Project Name
Conditioned Floor Area (ftZ)
Units
Number of Bedrooms
Number
of Zones
Cooling Systems
Heating Systems
Madison Lot 18B
10447
1
6
11
0
1
ZONE INFORMATION
01
02
03
05
06
07
Zone Floor Area
Avg. Ceiling
Zone Name
Zone Type
HVAC System Name
(ftZ)
Height
Water Heating System 1
Water Heating System 2
Master
Conditioned
HVAC Zone 31
1398
11.6
DHW Sys 1
n/a
Kitchen/Utility
Conditioned
HVAC Zone 31
e�
1297
112
DHW Sys 1
n/a
Office
Conditioned
HVAC Zone 12
833
12
DHW Sys 1
n/a
Bedroom 2
Conditioned
HVAC Zone 12 0
712
10
DHW Sys 1
n/a
Bar
Conditioned
HVAC Zone 12 `��
343
12
DHW Sys 1
n/a
Living/Foyer
Conditioned
HVAC Zone 23
1425
14
DHW Sys 1
n/a
Flex
Conditioned
HVAC Zo 23
609
12
DHW Sys 1
n/a
Rec Room
Conditioned
HVAC Zone 44
956
12
DHW Sys 1
n/a
Bedroom 3/Hall
Conditioned
HVAC Zone 44
777
10
DHW Sys 1
n/a
Bedroom 4
Conditioned
HVAC Zone 44
466
10
DHW Sys 1
n/a
Guest
Conditioned
HVAC Zone 55
4
1631
12
DHW Sys 1
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 4 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ftZ)
Window & Door Area (ftZ)
Tilt (deg)
N Wall
Master
R-21 Wall (W.21.2x6.16)
0
Right
660
98.9
90
E Wall
Master
R-21 Wall (W.21.2x6.16)
90
Front
45
0
90
S Wall
Master
R-21 Wall (W.21.2x6.16)
N 80
Left
276
66
90
W Wall
Master
R-21 Wall (W.21.2x6.16)
Back
405
198
90
Interior Surface
Master»Kitchen/Utility
R-0 Interior Wall ;
n/a
n/a
120
0
n/a
Roof -pitched
Master
R-38 Pitched Roof w/ R.--I,
n/a
n/a
1398
n/a
n/a
N Wall 2
Kitchen/Utility
R-21 Wall (W.21.2x6.16)
0
Right
170
24.3
90
W Wall 2
Kitchen/Utility
R-21 Wall (W.21.2x6.16)
270
Back
143
0
90
Interior Surface 2
Kitchen/Utility»Flex
R-0 Interio*,all
n/a
n/a
260
0
n/a
Interior Surface 3
Kitchen/Utility»Master
R-0 Interior Wall
n/a
n/a
120
0
n/a
Interior Surface 4
Kitchen/Utility»Living/Foyer
R-13'Wall
n/a
n/a
300
0
n/a
Roof -pitched 2
Kitchen/Utility
R-38 Pitied Roof w/ R-1
n/a
n/a
1297
n/a
n/a
N Wall 3
Office
R-21 Wall (W.21.2x6 16)
0
Right
120
113.3
90
E Wall 2
Office
R 21 Wall (W.21-2x6.16)
90
Front
321
113.3
90
S Wall 2
Office
E7R-21 Wall (W.21.2x6.16)
180
Left
380
92.5946
90
W Wall 3
Office
ti R-21 Wall (W.21.2x6.16)
270
Back
40
0
90
Interior Surface 5
Interior Surface 6
Office»Bar.°
Office»Bedroom 2 TY;
R-0 Interior Wall
R-0 Interior Wall
n/a
n/a
n/a
n/a
200
320
0
0
n/a
n/a
Roof -pitched 3
Office R
R-38 Pitched Roof w/ R-1
n/a
n/a
833
n/a
n/a
N Wall 4
Bedroom 2
R-21 Wall (W-21.2x6.16)
0
Right
95
0
90
E Wall 3
Bedroom k
R-21 Wall (W.21.2x6.16)
90
Front
80
0
90
S Wall 3
Bedroq
R-21 Wall (W.21.2x6.16)
180
Left
320
16.2
90
W Wall 4
Bedroom 2
R-21 Wall (W.21.2x6.16)
270
Back
240
120
90
Interior Surface 7
Bedroorn 2—Living/Foyer
R-0 Interior Wall
n/a
n/a
160
0
n/a
Interior Surface 8
Bedroom 2»Office
R-0 Interior Wall
n/a
n/a
320
0
n/a
Roof -pitched 4
Bedroom 2
R-38 Pitched Roof w/ R-1
n/a
n/a
712
n/a
n/a
E Wall 4
Bar
R-21 Wall (W.21.2x6.16)
90
Front
150
137.5
90
Interior Surface 9
Bar
R-0 Interior Wall
n/a
n/a
500
0
n/a
Interior Surface 10 '4
Bar»Office
R-0 Interior Wall
n/a
n/a
200
0
n/a
Interior Surface 11
Bar»Living/Foyer
R-0 Interior Wall
n/a
n/a
340
0
n/a
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
Page 5 of 16
Roof -pitched 5
Bar
R-38 Pitched Roof w/ R-1
n/a
n/a
343
n/a
n/a
E Wall 5
Living/Foyer
R-21 Wall (W.21.2x6.16)
90
Front
415.8
346,522
90
W Wall 5
Living/Foyer
R-21 Wall (W.21.2x6.16)
270
Back
632
572
90
Interior Surface 12
Living/Foyer»Bedroom 2
R-0 Interior Wall
n/a
n/a
160
0
n/a
Interior Surface 13
Living/Foyer»Bar
R-0 Interior Wall
n/a
n/a
340
0
n/a
Interior Surface 14
Living/Foyer»Kitchen/Utility
R-13 Wall
n/a
n/a
300
0
n/a
Interior Surface 15
Living/Foyer»Flex
R-0 Interior Wall
r`'n/a
n/a
375
0
n/a
Roof -pitched 6
Living/Foyer
R-38 Pitched Roof w/ R-1
"�� n/a
n/a
1425
n/a
n/a
E Wall 6
Flex
R-21 Wall (W.21.2x6.16)
90
Front
138
113.3
90
S Wall 4
Flex
R-21 Wall (W.21.2x6.16)
180
Left
132
113.3
90
Interior Surface 16
Flex»Living/Foyer
R-0 Interior Wall
n/a
n/a
375
0
n/a
Interior Surface 17
Flex»Kitchen/Utility
R-0 Interior WIM
n/a
n/a
260
0
n/a
Roof -pitched 7
Flex
R-38 Pitched Roof w/ R-1
n/a
n/a
609
n/a
n/a
N Wall 5
Rec Room
R-21 Wall (W.21.2x6.16)
0
Right
324
132
90
S Wall 5
Rec Room
R-21 Wall ".21.24.16)
180
Left
324
264
90
W Wall 6
Rec Room
R-2144all (W.21.2x6.16)
270
Back
54
0
90
Interior Surface 18
Rec Room»Bedroom 3/Hall
Ft-0 Interior Wall
n/a
n/a
120
0
n/a
Interior Surface 19
Rec Room»Bedroom 4
., R-0 Interior Wall
n/a
n/a
160
0
n/a
Roof -pitched 8
Rec Room
i2-38 Pitched Roof w/ R-1
n/a
n/a
956
n/a
n/a
N Wall 6
Bedroom 3/Hall
R-21 Wall (W.21.2x6.16)
0
Right
60
48
90
E Wall 7
Bedroom 3/Hall
R-21 Wall (W.21.2x6.16)
90
Front
280
24
90
S Wall 6
Bedroom 3/Hall
R-21 Wall (W.21.2x6.16)
180
Left
310
47.5
90
W Wall 7
Bedroom 3/Hall'Fa
R-21 Wall (W 21.2x6.16)
270
Back
115
0
90
Interior Surface 20
Bedroom 3/Hall—Bedroom 4
R-0 Interior Wall
n/a
n/a
210
0
n/a
Interior Surface 21
Bedroom 3/Hall>,>Jiec Room
R-0 Interior Wall
n/a
n/a
120
0
n/a
Roof -pitched 9
Bedroom 3/Hap
R-38 Pitched Roof w/ R-1
n/a
n/a
777
n/a
n/a
N Wall 7
Bedroom 4
R-21 Wall (W.21.2x6.16)
0
Right
240
11.7
90
E Wall 8
Bedroom 4
R-21 Wall (W.21.2x6.16)
90
Front
190
0
90
Interior Surface 22
Bedr4—Bedroom 3/Hall
R-0 Interior Wall
n/a
n/a
210
0
n/a
Interior Surface 23
Bedroom 4»Rec Room
R-0 Interior Wall
n/a
n/a
160
0
n/a
Roof -pitched 10
6- Bedroom 4
R-38 Pitched Roof w/ R-1
n/a
n/a
466
n/a
n/a
N Wall 8
Guest
R-21 Wall (W.21.2x6.16)
0
Right
528
110
90
E Wall 9
Guest
R-21 Wall (W 21.2x6.16)
90
Front
459
104.2
90
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 6 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
S Wall 7
Guest
R-21 Wall (W.21.2x6.16)
180
Left
480
40
90
W Wall 8
Guest
R-21 Wall (W.21.2x6.16)
270
Back
495
20.07
90
Interior Surface 24
Guest»Living/Foyer
R-0 Interior Wall
n/a
n/a
5
0
n/a
Roof -pitched 11
Guest
R-38 Pitched Roof w/ R-1
n/a
n/a
1631
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise 41
1
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master
Attic RoofMaster
Ventilated
3 �r'
0.1
0.85
Yes
No
Attic Kitchen/Utility
Attic RoofKitchen/Utility
Ventilated
0.1
0.85
Yes
No
Attic Office
Attic RoofOffice
Ventilated
3
0.1
0.85
Yes
No
Attic Bedroom 2
Attic RoofBedroom 2
Ventilated
'� 3
01
0.85
Yes
No
Attic Bar
Attic RoofBar
Ventilated
3
0.1
0.85
Yes
No
Attic Living/Foyer
Attic RoofLiving/Foyer
Ventilated
0.1
0.85
Yes
No
Attic Flex
Attic RoofFlex
Ventilated
3
0.1
0.85
Yes
No
Attic Rec Room
Attic RoofRec Room
Ventilated �,
3
0.1
0.85
Yes
No
Attic Bedroom 3/Hall
Attic RoofBedroom 3/Hall
Ventilateds,
3
0.1
0.85
Yes
No
Attic Bedroom 4
Attic RoofBedroom 4
Ventilated
3
0.1
0.85
Yes
No
Attic Guest
Attic RoofGuest
Ventilated
3
0.1
0.85
Yes
No
oe
V
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
Page 7 of 16
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U-factor
SHGC
Exterior Shading
3X5
Window
N Wall (Right-0)
----
-
1
15.0
0.39
0.31
Insect Screen (default)
3X5 2
Window
N Wall (Right-0)
-
-
1
15.0
0.39
0.31
Insect Screen (default)
2.5X2.5
Window
N Wall (Right-0)
----
----
1
6.3
0.50
0.26
Insect Screen (default)
2.5X10
Window
N Wall (Right-0)
----
-
1
25.0
0.39
0.31
Insect Screen (default)
2.5X10 2
Window
N Wall (Right-0)
---
1
25.0
0.39
0.31
Insect Screen (default)
2.5X2 5 2
Window
N Wall (Right-0)
-
-
1
6.3
0.50
0.26
Insect Screen (default)
2.5X2.5 3
Window
N Wall (Right-0)
----
--
1
6.3
0.50
0.26
Insect Screen (default)
6X11
18X11
Window
Window
S Wall (Left-180)
W Wall (Back-270)
6.0
18.0
11.0
11.0
1
1
66.0
198.0
0.39
0.39
0.32
0.32
Insect Screen (default)
Insect Screen (default)
4X4.5
Window
N Wall 2 (Right-0)
---
----
1
18.0
0.50
0.26
Insect Screen (default)
4X4.5 2
Window
N Wall 2 (Right-0),
----
--
1
6.3
0.50
0.26
Insect Screen (default)
10.3X11
Window
N Wall 3 (Right-0)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
10.3X11 2
Window
E Wall 2 (Front 90)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
6X11 2
Window
S Wall 2 (Left•180)
-
--
1
66.0
0.39
0.31
Insect Screen (default)
2.7X2.7
Window
S Wall 2 (Left-180)
2.7
2.7
1.001
7.3
0.50
0.26
Insect Screen (default)
3X4
Window
S Wall 2 (Left-180)
3.0
4.0
1
12.0
0.39
0.31
Insect Screen (default)
2.7X2.7 2
Window
S WalI 2 (Left-180)
2.7
2.7
1.001
7.3
0.50
0.26
Insect Screen (default)
2X2.7
Window
8 Wall 3 (Left-180)
----
-
1
5.4
0.50
0.26
Insect Screen (default)
4X2 7
Window
S Wall 3 (Left-180)
-
----
1
10.8
0.50
0.26
Insect Screen (default)
12X10
Window
W Wall 4 (Back-270)
12.0
10.0
1
120.0
0.39
0.32
Insect Screen (default)
12.5X11
Window
E Wall 4 (Front-90)
12.5
11.0
1
137.5
0.39
0.31
Insect Screen (default)
12.6X11
Window
E Wall 5 (Front-90)
19.0
11.0
0.663
138.6
0.39
0.31
Insect Screen (default)
6.3X11
Window
E Wall 5 (Front-90)
19.0
11.0
0.332
69.4
0.92
0.59
Insect Screen (default)
12.6X11 2
Window
E Wall 5 (Front-90)
19.0
11.0
0.663
138.6
0.39
0.31
Insect Screen (default)
44X13
Window
W Wall 5 (Back-270)
44.0
13.0
1
572.0
0.39
0.32
Insect Screen (default)
10.3X11 3
Window
E Wall 6 (Front-90)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
10.3X11 4
Window
S Wall 4 (Left-180)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
6X11 3
Window
N Wall 5 (Right-0)
----
-
1
66.0
0.50
0.26
Insect Screen (default)
6X11 4
Window
N Wall 5 (Right-0)
-
1
660
0.50
0.26
Insect Screen (default)
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 8 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
24X11
Window
S Wall 5 (Left-180)
24.0
11.0
1
264.0
0.39
0.32
Insect Screen (default)
6X8
Window
N Wall 6 (Right-0)
----
----
1
48.0
0.50
0.26
Insect Screen (default)
2.5X3
Window
S Wall 6 (Left-180)
1
7.5
0.50
0.26
Insect Screen (default)
8X5
Window
S Wall 6 (Left-180)
----
----
1
40.0
0.50
0.26
Insect Screen (default)
8X5 2
Window
N Wall 7 (Right-0)
----
1
5.4
0.51
0.26
Insect Screen (default)
2.5X3 2
Window
N Wall 7 (Right-0)
----
---
1
6.3
0.50
0.26
Insect Screen (default)
10X11
Window
N Wall 8 (Right-0)
10.0 �?f
r 11.0
1
110.0
0.39
0.32
Insect Screen (default)
3X8
Window
E Wall 9 (Front-90)
1
24.0
0.51
0.26
Insect Screen (default)
8X8
Window
E Wall 9 (Front-90)
1
64.0
0.50
0.26
Insect Screen (default)
6X2.7
Window
E Wall 9 (Front-90)
--
1
16.2
0.50
0.26
Insect Screen (default)
8X5 3
Window
S Wall 7 (Left-180)
..-•
1
40.0
0.50
0.26
Insect Screen (default)
2.5X3 3
Window
W Wall 8 (Back-270)
1
7.5
0.50
0.26
Insect Screen (default)
3.5X4.5
Window
W Wall 8 (Back-270)
---
1
6.3
0.50
0.26
Insect Screen (default)
15X11
Window
W Wall 8 (Back-270)
15.0
11.0
0.038
1 6.3
0.39
0.32
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ft)
U-factor
Door
= 't E Wall 7
24.0
0.50
%6q
4.
14�2
401z�
Registration Number: Registration DatefFime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:06, Fri, May 03, 2019
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
CF1 R-PRF-01
Page 9of16
OVERHANGS AND FINS
01
02
03
04
05
06
07
08 09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
6X11
4
0.1
4
4
0
0
0
0
0
0
0
0
18X11
8
0.1
8
8
0
0
0
0
0
0
0
0
0
10.3X11
10
0.1
10
10
0
0
0
0
0
0
0
0
0
10 3X11 2
18
0.1
18
18
0
0
0
0
0
0
0
0
0
2.7X2.7
3
0.1
3
0
0
0
0
0
0
0
0
0
0
3X4
3
0.1
3
0
0
0
0
0
0
0
0
0
0
2.7X2.7 2
3
0.1
3
0
`&
0
0
0
0
0
0
0
0
12X10
14
0.1
14
14
0
0
0
0
0
0
0
0
0
12.5X11
14
0.1
14
14
0
0
0
0
0
0
0
0
0
12.6X11
14
0.1
14
14� O
0
0
0
0
0
0
0
0
0
6.3X11
14
0.1
14
K
0
0
0
0
0
0
0
0
0
12.6X112
14
0.1
14
C14
0
0
0
0
0
0
0
0
0
44X13
22
0.1
22
0
0
0
0
0
0
0
0
0
0
10.3X11 3
8
0.1
8
8
0
0
0
0
0
0
0
0
0
10.3X114
10
0.1
10
10
0
0
0
0
0
0
0
0
0
24X11
12
0.1
42
12
0
0
0
0
0
0
0
0
0
10X11
4
0.1
4
4
0
0
0
0
0
0
0
0
0
15X11
18
0.1�
18
18
0
0
0
0
0
0
0
0
0
Registration Number: Registration DatefFime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CFI R-PRF-01
Page 10 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster
Attic Roofs
Wood Framed Ceiling
in. O.0
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-14.3/2x6
R-38 Pitched Roof w/ R-1
attic)
Wood Framed Ceiling
2x6 @ 16 in O.C.
R 38
0.026
- Over Ceiling Joists: R-23.7 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in, O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
V4.1
Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.277
Other Side Finish: Gypsum Board
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck., Wood Siding/sheathing/decking
Attic RoofKitchen/Utility
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.092
Other Side Finish: Gypsum Board
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofOffice
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Around Roof Joists: R-0.0 insul.
Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedroom 2
Attic Roofs
Wood Framed Ceiling
in O C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBar
Attic Roofs
Wood Framed Ceiling
in O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving/Foyer
4ttilyoofs
Wood Framed Ceiling
in O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Registration Number: Registration DatefFime: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 11 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofFlex
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofRec Room
Attic Roofs
Wood Framed Ceiling
in. O C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedroom 3/Hall
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Around Roof Joists: R-0.0 insul.
Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedroom 4
Attic Roofs
Wood Framed Ceiling
in. Q.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Around Roof Joists: R-0.0 insul.
Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofGuest
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab
Master
1398
125
None
0.8
No
Slab 2
Kitchen/Utility
1297
125
None
0.8
No
Slab 3
Office
833
73
None
0.8
No
Slab 4
Bedroom 2
712
71
None
08
No
Slab 5
Bar
343
14
None
0.8
No
Slab 6
Living/FNpr
1425
125
None
08
No
Slab 7
Flax
609
23
None
0.8
No
Slab 8
Rec Room
956
76
None
0.8
No
Slab 9
Bedroom 3/Hall
777
71
None
0.8
No
Slab 10
Bedroom 4
466
14
None
0.8
No
Slab 11
$4/ Guest
1631
184
None
0.8
No
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 12 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1
DHW
Standard
DHW Heater 1 (2)
2
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy.
Pilot /
Insulation
Loss I
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small
Instantaneous
2
0
0.95 EF
<= 200 kBtu/hr
R-0/R-0
0
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC Zone 31
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC Zone 12
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC Zone 23
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC Zone 44
Otiper Heatina and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
HVAC Zone 55
Other Heating and Cooling
System
Heating Component 5
Cooling Component 5
HVAC Fan 5
Air Distribution System 5
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Datefrime: 11:06, Fri, May 03, 2019
CFI R-PRF-01
Page 13 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Heating Component 2
CntrlFurnace
1
80 AFUE
Heating Component 3
CntrlFurnace
1
80 AFUE
Heating Component 4
CntrlFurnace
1
80 AFUE
Heating Component 5
CntrlFurnace
1
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
-C' Efficiency
Name
System Type
Number of Units
Kw EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
Cooling Component 5
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
5-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
4' Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Cooling Component 5-hers-cool
Required
350
Required
Required
Required
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CFI R-PRF-01
Page 14 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
2-hers-dist
Air Distribution System 3
y
DuctsAttic
Specified Lower Leakage
Target
9
8
Attic
None
Air Distribution System
3-hers-dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage
Target
Attic
None
Air Distribution System
4-hers-dist
Air Distribution System 5
DuctsAttic
Specified Lower Leakage
Target
8
Attic
None
Air Distribution System
5-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)�,
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-dist
Required
60
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-dist
Required
s' 6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 5-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.5
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.5
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.5
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.5
HVAC Fan 4-hers-fan
HVAC Fan 5
Single Speed PSC Furnace Fan
0.5
HVAC Fan 5-hers-fan
•.0
oe
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
HERS Provider:
Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 15 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.50
HVAC Fan 2-hers-fan
Required
0.50
HVAC Fan 3-hers-fan
Required
0.50
HVAC Fan 4-hers-fan
Required,QJ
0.50
HVAC Fan 5-hers-fan
Required
0.50
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
157
015
Default
0
Required
`14
UVO
Registration Number: Registration DateRme: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 16 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date
Scott Design and Title 24, Inc,
5/3/2019
Address: 74-818 Velie Way, Suite #8
CEAMERS Certification Identification (If applicable):
Zin
cay/star F dl:m Desert, CA 92260
PI,°ne (760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California.
1. I am eligible under Division 3 of the Business and Professions Code to accept responsiWity for the building design identified on this Certificate of Compliance
2. 1 certify that the energy features and performance specifications identified on this CeMCate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate. of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application
Responsible Des i ner Name:
Mark Wa6dford
Responsible Designer Signature:
Company:
Mark Radford Architecture
Date Signed:
Address:
2282 Via Cascabel
License:
City/State/Zip:
Escondido, CA 92027 ,,
Phone:
(760) 432-0348
Registration Number: Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Custom Residence -The Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
California Energy Climate Zone Total Cond. Floor Area Addition
CA Climate Zone 15 10,447 n/a
Date
5/3/2019
# of Units
FI
Project Address
Lot 18-B, 52355 Meriwether La Quinta
INSULATION
Construction Type
Cavity
Area
WSpecial Features
Status
Roof Wood Framed Attic
Wall Wood Framed
Slab Unheated Slab -on -Grade
R 38
R 21
no insulation
10,447 Add=R-13.0
5,695
9,670 Perim = 830'
New
New
New
Demising Wood Framed
- no insulation
5,035
New
Demising Wood Framed
R 13
600
New
Door Opaque Door
no insulation
24
New
Slab Unheated Slab -on -Grade
- no insulation
777 Perim = 71'
Altered
FENESTRATION
Orientation Area ft)
Total Area: 2,903 Gsazing Percentage: 278 %
U-Fac SHGC Overhang Sidefins
NewlAltered Average U-Factor:
Exterior Shades
0•42
Status
Right (N) 80.0
0.390
0.31 none
none
Bug Screen
New
Right (N) 229.5
0.500 0.26 none
none
Bug Screen
New
Left (S) 66.0
0.390 0.32 4.0
none
Bug Screen
New
Rear (W) 198.0
0.390 0.32 8.0
none
Bug Screen
New
Right (N) 113.3
0.390 0.32 10.0
none
Bug Screen
New
Front (E) 113.3
0.390 0.32 18.0
none
Bug Screen
New
Left (S) 66.0
0.390 0.31 none
none
Bug Screen
New
Left (S) 14.6
0.500 0.26 3.0
none
Bug Screen
New
Left (S) 12.0
0.390 0.31 3.0
none
Bug Screen
New
Left (S) 103.7
0.500 0.26 none
none
Bug Screen
New
Rear (M 120.0
0.390 0.32 14.0
none
Bug Screen
New
Front (E) 414.7
0.390 0.31 14.0
none
Bug Screen
New
Front (E) 69.3
0.920 0.59 14.0
none
Bug Screen
New
Rear (W) 572.0
HVAC SYSTEMS
Qty. Heating
0.390 0.32 22.0
Min. Eff Cooling
none
Min. Eff
Bug Screen
Thermostat
New
Status
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
1 Central Furnace 80% AFUE
1 Central Furnace 80% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 16, 0 SEER
Split Air Conditioner 16.0 SEER
Cooling Duct Location
Setback
Setback
Duct
R-Value
New
New
Status
HVAC Zone 3 Ducted
HVAC Zone 1 Ducted
HVAC Zone 2 Ducted
WATER HEATING
Qty. Type
Ducted Attic 8.0
Ducted Attic 80
Ducted Attic 60
Gallons Min. Eff Distribution
New
New
New
Status
2 Small Instantaneous Gas
0
0.95
Standard
New
Ever Pro 7.2 by EnerqySoft User Number: 6712
ID:
Page 19 of 61
RESIDENTIAL MEASURES SUMMARY
RMS-1
Project Name
Custom Residence -The Madison Club
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
51312019
Project Address
Lot 18-8, 52355 Meriwether
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
10,447
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity (ft) Special Features
Status
FENESTRATION
Orientation Area(ft2)
Ilicital Area: Z903 G lazing Percentage: 2 7. 6 %
U-Fac SHGC Overhang Sidefins
New/Altered Averse U-Factor.
Exterior Shades
0.42
Status
Front (E) 1133
0.390
0.32 8.0 none
Bug Screen
New
Left (S) 1133
0.390
0.32 10.0 none
Bug Screen
New
Left (S) 264.0
0.390 0.32 12.0 none
Bug Screen
New
Right (N) 5.4
0.510 0.26 none none
Bug Screen
New
Right (N) 110.0
0.390 0.32 4.0 none
Bug Screen
New
Front (E) 24.0
0.510 0.26 none none
Bug Screen
New
Front (E) 80.2
0.500 0.26 none none
Bug Screen
New
Rear (VV) 13.8
0.500 0.26 none none
Bug Screen
New
Rear (M 6.3
0.390 0.32 18.0 none
Bug Screen
New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat
Status
1 Central Furnace 80 % AFUE
1 Central Furnace 80% AFUE
HVAC DISTRIBUTION
Location Heating
Split Air Conditioner 16.0 SEER
Split Air Conditioner 16.0 SEER
Cooling Duct Location
Setback
Setback
Duct
R-Value
New
New
Status
HVAC Zone 4 Ducted
HVAC Zone 5 Ducted
WATER HEATING
-Qty. Type
Ducted Attic 8.0
Ducted Attic 8.0
Gallons Min. Eff Distribution
New
New
Status
EnergyPro 7.2 by Ener�qySoft User Number. 6712
ID:
Pape 20 of 61
2016 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(Revised 04/2017a
Building Envelope Measures:
§ 110.6(a)l:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft2 or less when tested per
NFRC-400 orASTME283 orAAMAIWDMAICSA 10l/I.S.2/A440-2011.'
§ 110.6(a)5
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from TABLES
110.E-A and 110.6-B for compliance and must be caulked and/or weatherstrip ed. '
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to la�cin insulation either above or below the roof deck or on top of a dD2all ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value.
Above Grade Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less (R-19 in 2x6 or U-
§ 150.0(c):
factor of 0.074 or less). Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102, equivalent to an installed
value of R-13 in a wood framed assembl .'
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.`
§ 150.0(9:
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8.
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
requirement also applies to controlled ventilation crawls ace for buildings complying with the exce tion to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.*
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)lA:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)l B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)l C:
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.1
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.`
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§ 110.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementa heating.*
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on bath cold water and hot water lines of water heating systems to allow for water tank flushin2 when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt): and pool and spa heaters!
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in 150.0 h 2,
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulations or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)2B:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or steeve!
§ 150.06)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)3B:
_
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150 0(n)3,
Solar Water -heating Systems. Solar water- heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency -that is approved b the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than Y< inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross -sectional area of the ducts:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and Other requirements sp2cifled for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow > 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced air systems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(o):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on -off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.*
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fanspeed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1 C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1 C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).'
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1 G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JA8.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5 ; and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5(f); and all other requirements in 6 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according toll 10.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JA8, except luminaires in closets less than 70 square feet and luminaires in hallways.*
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control. astronomical time clock, or
EMCS).
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either 150.0 k 3A or with theapplicable requirements in §§ 110.9, 130.0, 130.2, 130.4. 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0 k 3B or § 150.0 k 30 must comply with the a licable requirements in §§ 110.9,130.0,130.2,130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9. 130.0 130.2, 130.4, 140.7, and 141.0,
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0 c .
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
I. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.10 b through § 110.10(e).
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.'
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)313:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane."
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel): and a pathway for routing of plumbing from the solar zone to the water -heating s stem.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
110.10 C must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as "For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 3
Date
5/3/2019_
Floor Area
2,695
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING
CFM Sensible
Total Room Loads 2,791 26,638
Return Vented Lighting 0
Return Air Ducts 1,538
Return Fan 0
Ventilation 512 18,974
Supply Fan 0
Supply Air Ducts 1,538
TOTAL SYSTEM LOAD 48,687
PEAK COIL HTG.
Latent CFM
3,356 752
-439 512
2,917
PEAK
Sensible
Heating System
Output per System
80
29,517
Total output Btuh
80
Output Btuh/s ft
0.0
1,451
Cooling System
0
Output per System
37,200
2446 ,4
Total Output Btuh
37,200
0
Total Output Tons
3.1
1,451
Total Output Btuh/s ft
13.8
Total Output s ft/Ton
869.4
56,883
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Trane 5 Ton
33,504
4,053
80
Airflow cfm/s ft)
0.45
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
80
Jan 1 AM
Airflow (cfm/Ton)
387.1
Outside Air (%)
42.7 %
33,504
4,053
Outside Air (cfm/s ft)
0.19
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
512 cfm
71 OF
4
52 OF 110 °F
Heating Coil Supply Fan
1,200 cfm
U-11- T
109 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS JAirstrearn Temperatures at Time of Cooling Peak
112/78OF
Outside Air Ar
512 cfm
92/73°F 66/64°F 66/64°F
1 I— f
Cooling Coil Supply Fan 67 / 65 °F
1,200 cfm ROO�
67.6
76 / 68 OF
FLEE • '
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 1
Date
5/3/2019
Floor Area
1,888
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,934
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 354
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK
COIL HTG.
PEAK
Heatinp System
Sensible
Latent
CFM
Sensible
26,619
Output perS stem
Total Output Btuh)
80
80
24,400
2,351
676
0
Output (Btuh/s ft)
0.0
1,409
1,308
Cooling System
0
0
Output perS stem
37.200
13,142
1.844
354
16,931
Total Output Btuh)
37,200
0
1,409
1 40,359 4, 994
0
Total Output Tons
3.1
1,308
Total Output Btuh/s ft)
19.7
Total output s ft/Ton
609.0
46,173
Air System
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Trane 5 Ton
31,101
4,988
80
Airflow cfm/s ft
0.64
Airflow cfm/Ton
387.1
Outside Air %
29•5 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
31,101 4,988
Aug 3 PM
80
Jan 1 AM
Outside Air (cfm/s ft)
0.19
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
(Airstream Temperatures at Time of Heating
Peak
26 OF
Outside Air
354 cfm
71 OF
If
58 OF
Heating Coil Supply Fan
1,200 cfm
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling
Peak)
112/78IF
Outside Air
354 cfm
87/70OF 63/62OF 63/62OF
I F-1
Cooling Coil Supply Fan
1,200 cfm
I— U
61.2 %
64 / 62 OF
ROOM YJ
7a , nG
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 2
Date
5/3/2019
Floor Area
2,034
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 3,650
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 454
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System
80
36,515
2,533
901
35,142
Total Output (Btuh)
B0
0
Output Btuh/s ft
0.0
2,108
1,727
Cooling System
0
0
Outgut per System
37,200
16,607
705F
454
21,586
Total Output (Btuh)
37,200
0
3.238
0
Total Output (Tons
3.1
2,108
1,727
Total Output Btuh/s ft
18.3
Total Output s ft/Ton
656.1
1 57,337
60,183
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Trane 5 Ton
32,827
4,255
80
Airflow cfm/s ft
0.59
32,827 4,255 80
Aug 3 PM Jan 1 AM
Airflow cfm/Ton
387.1
Outside Air (%)
37.9 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
Outside Air (cfm/s ft)
0.22
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak)
26 OF
Outside Air
454 cfm
71 OF
54 OF 110 OF 110 °F
Heating Coil Supply Fan
1,200 cfm 109 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/78OF
Outside Air Ak-
454 cfm
91/72°F 65/63°F 65/63°F
Cooling Coil Supply Fan 67 / 64 OF
1,200 cfm
65.0 % ROOM
76/�-
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
Custom Residence -The Madison Club 5/3/2019
System Name Floor Area
HVAC Zone 4 2,199
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL COOLING PEAK COIL HTG.
CFM Sensible Latent CFM
Total Room Loads 2,171 25,235 2,738 727
Return Vented Lighting 0
Return Air Ducts 1,4571
Return Fan 0
Ventilation 398 14,779 1,272 398
Supply Fan 0
Supply Air Ducts 1,457
TOTAL SYSTEM LOAD 42,928 4,0710
PEAK
Heating System
Sensible
Output per System
80
28,538
Total Output Btuh)
80
Output (Btuh/s ft)
0.0
1,403
Cooling System
0
Output erS stem
37.200
19,036
Total Output Btuh
37,200
0
Total Output Tons
3•1
1,403
Total Output Btuh/s ft
16.9
Total Output s ft/Ton
709.4
50,379
Air System
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Trane 5 Ton 31,642 4,921
Total Adjusted System Output 31,642 4,921
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
80
80
Jan 1 AM
Airflow cfm/s ft
0.55
Airflow (cfm/Ton)
387.1
Outside Air %
33 2 %
Outside Air (cfm/s ft)
0.18
conditions
Note: values above given at ARI
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Mating Peak
26 OF
—0-0-
Outside Air
398 cfm
71 OF
56 OF 110 °F 110 °F
IP 0 _ Tr
Heating Coil Supply Fan
1,200 cfm 109 OF
ROOM
1 72 OF
COOLING SYSTEM PSYCHROMETRiCS Airstream Temperatures at Time of Cooling Peak
112/78OF
Outside Air
398 cfm
77/67°F
89/71 OF 64/62°F 64/62°F
op
a LLLLU
Cooling Coil Supply Fan 65 / 63 OF
1,200 cfm
63.3 % ROOM
76/67°F
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Custom Residence -The Madison Club _
System Name
HVAC Zone 5
Date
5/3/2019
Floor Area
1,631
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
_ COIL
CFM
Total Room Loads 1.447!
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 326
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem
80
19,669
2,031
587
23,194
Total Output Btuh
80
0
Output Btuh/s ft
0.0
1,135
1,140
Cooling System
0
0
Output perSystem
37,200
12,189
2,217
326
15,659
Total Output Btuh
37,200
0
4,247
0
Total Output Tons
3 1
1,135
1,140
Total Output Btuh/s ft
22.8
Total Output s ft/Ton
5261
34,128
41,133
Air System
CFM perSystem
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
1,200
Trane 5 Ton
30,771
4,947
80
Airflow cfm/s ft
0.74
Airflow cfm/Ton)
387.1
Outside Air (%)
27.2 %
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
30,771
4,947
80
Jan 1 AM
Outside Air (cfm/sgft)
0.20
Note: values above given at ARI conditions
Aug 3 PM
HEATING SYSTEM PSYCHROMETRICS (Airstream
Temperatures at Time of Heating Peak)
26 OF
Outside Air
326 cfm
71 OF
59 OF 110 OF 110 IF
• T
Heating Coil Supply Fan
1,200 cfm
109 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak
112/78IF
Outside Air
326 cfm
77 / 66 OF
86/70°F 62/61 OF 62/61 OF
I
I
Cooling Coil Supply Fan 153161 'IF
1,200 cfm -
59.5 % ROOM
76 !Cis O
ZONE LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
System Name
HVAC Zone 3
Floor Area
2,695
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Master
1.0
270
Aug 3 PM
1,924
28,718
5,996
488
32, 363
Kitchen/Utility
1.0
242
Aug 3 PM
867
17,551
5,427
265
22,238
TOTALS 0 01 0 512 Aug 3 PM 46,268 11, 423 54,601
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
System Name Floor Area
HVAC Zone 1 1,888
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Office
1.0
167
Aug 3 PM
951
18,379
3,660
330
21,154
Bedroom 2
1.0
119
Aug 3 PM
619
12,353
2,755
239
15, 207
Bar
1.0
69
Aug 3 PM
364
7,226
11507
107
7,581
TOTALS
0
0
0
354
Aug 3 PM j
37,957
T 922
43,942
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 2
Date
5/3/2019
Floor Area
2,034
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Living/Foyer
1.0
333
Aug 3 PM
2,764
40,386
7,009
717
44, 231
Flex
1.0
122
Aug 3 PM
886
13,534
2,676
184
13,151
TOTALS1
0
0
0
454
Aug 3 PM
53, 920
9,685
57,382
(BLOCK LOAD
ZONE LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
System Name
HVAC Zone 4
Floor Area
2,199
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heatin
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM
Sensible
Rec Room
1-0
191
Aug 3 PM
1,175
20,985
4,201
376
24,130
Bedroom 3/Hall
1.0
130
Aug 3 PM
684
12,909
3,006
255
16,345
Bedroom 4
1.0
78
Aug 3 PM
312
6,603
1,803
96
7,565
TOTALS
0
0
0
398
Aug 3 PM 1
40,4981
9,0101
48,039
(BLOCK LOAD)
ZONE LOAD SUMMARY
Project Name Date
Custom Residence -The Madison Club 5/3/2019
System Name Floor Area
HVAC Zone 5 1,631
ZONE LOAD SUMMARY
ZONAL SYSTEM
COOLING PEAK
HEATING PEAK
ZONE NAME
SYSTEM NAME
Mult.
CFM
Sensible
Latent
Heating
OA CFM
Peak Hr
CFM
Sensible
Latent
CFM Sensible
Guest
1.0
326
Aug 3 PM
1,447
32,166
7,167
587
39,163
TOTALS
1 0
0
0
326
Aug 3 PM
32,166
7,167
39,163
(BLOCK LOAD
ROOM LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 3
ROOM LOAD SUMMARY
Date
5/3/2019
Floor Area
2,695
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible
Master Master Bedroom 1 1,924 18,363 1,741 1,924 18,363 1,741 488 19,131
Kitchen/Utility Kitchen & Utility 1 867 8,275 1,615 867 8,275 1,615 265 10,386
PAGE TOTAL
TOTAL"
I ` Total includes ventilation load for zonal
2,791
26,638 3,3561
752
29, 577
2,791
26,6381 3,3561
752
29.5171
ROOM LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
Floor Area
1,888
System Name
HVAC Zone 1
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name
Room Name
Mult.
CFM
Sensible
Latent
CFM
Sensible
Latent
CFM
Sensible
Office
Office
1
951
11,996
1,037
951
11,996
1.037
330
12,999
Bedroom 2
Bedroom 2
1
619
7,806
887
619
7,806
887
239
9,398
Bar
Bar
1
3641
4,598
427
364
4,598
427
107
4,223
PAGE TOTAL 1,934 24,400 2,35.1 676 26,619
TOTAL * 1,934 24, 400 2, 351 676 26, 619
Total includes ventilation load for zonal systems.
ROOM LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 2
ROOM LOAD SUMMARY
Date
5/3/2019
Floor Area
2,034
ROOM COOLING PEAK I COIL COOLING PEAK COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible I Latent CFM Sensible
Living/Foyer Living/Foyer 1 2,764 27,647 1,774 2,764 27,647 1,774 717 27,954
Flex Flex 1 886 8,868 7581 8861 8,8681 758 184 7,188
Total
zonal
PAGE TOTAL
TOTAL*
3,650
36,515
2,5331
907
35,142
3.6501
36,5151
2,5331
901
35,142
ROOM LOAD SUMMARY
Project Name
Custom Residence -The Madison Club
System Name
HVAC Zone 4
ROOM LOAD SUMMARY
Date
5/3/2019
Floor Area
2,199
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
Zone Name
Room Name
Mult.
CFM
Sensible I
Latent
CFM
Sensible
Latent
CFM
I Sensible
Rec Room
Rec./Media
1
1,175
13,660
1,190
1,175
13,660
1,190
376
14,770
Bedroom 3/Hall
Bedroom 3
1
684
7,948
967
684
7,948
967
255
10,005
Bedroom 4
Bedroom 4
1
3121
3,627
580
312
3,627
580
96
3,763
PAGE TOTAL
TOTAL*
j ' Total includes ventilation load for zonal
2,171
25,2351
Z 738
727 28, 538
2,171
25, 235
2,7381
727 28,5381
ROOM LOAD SUMMARY
Project Name Date
Custom Residence -The Madison Club 5/3/2019
System Name Floor Area
HVAC Zone 5 1,631
ROOM LOAD SUMMARY
Zone Name I Room Name
Guest I Guest
Total includes ventilation load for
ROOM COOLING PEAK
Mult. CFM i Sensible I Latent
1 1,4471 19,6691 2,031
PAGE TOTAL
TOTAL*
COIL COOLING PEAK COIL HTG. PEAK
CFM Sensible I Latent CFM I Sensible
1,4471 19,6691 2,0311 5871 23,194
1,447 19, 669
1 2.0311
587
23,194
1,447 19.669
2.031
587
23.i94
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Bedroom
Floor Area 1,398.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Pitched Roof wl R-13
1,398.0
0.0236
46
1,515
R-21 Wall (W.21.2x8.16)
1,023.1
0.0690
46
3,247
Fixed .39131
80.0
0.3900
46
1,435
Casement _51..26
18.9
0.5000
46
435
Patio Door.39L32
264.0
0.3900
46
4.736
Slab -On -Grade
perim = 125, 0
0.7300
46
4,198
"R-0 Interior Wall
120.0
0.3560
0
0
X
X
X
X
Page Total
/ 60 ] X
AT
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,398 X
Area
another room
11.60 X 0.270
Heighl ACH
15,565
= 3,566
TOTAL HOURLY HEAT LOSS FOR ROOM 19,131
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Kitchen & Utility
Floor Area 1,297.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
461
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Filched Roof w/l- 13
1,297.0
0.0236
1,405
R-21 Well (W.21.24.16)
288.7
0.0690
46
916
Casement .51..26
24.3
0.5000
46
559
Slab -an -Grade
perim = 125.0
0.7300
46
4,198
'R-0 Interior Well
380.0
0.3560
0
0
'R-13 Wall
300.0
0.1020
0
0
through an interior surface
X 1,297 X
Area
Items shown wjth an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
Page Total
/ 60 ] X
AT
another room
11.20 X 0.279
Height ACH
7,078
= 3,308
TOTAL HOURLY HEAT LOSS FOR ROOM 10,386
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Office
Floor Area 833.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
L
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4T °F
=
=
=
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_
4fi
Btu/hr
R-38 Pitched Roof w1 R-13
833.0
0.0236
46
902
R•21 Wall {W.21.2x6.16]
541.8
0.0690
46
1,720
Patio poor .391..32
226.6
0.3900
46
4,065
Fixed .39131
78.0
0.3900
46
1,399
Casement .51..26
14.6
0.5000
46
336
Slab -On -Grade
perim = 73.0
0.7300
46
2,451
•R-0 Interior Well
520.0
0.3560
0
0
another room
12.00 X 0.261
Height ACH
Page Total
/ 60 ] X
AT
Items shown with an asterisk (") denote conduction
Infiltration-[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 8331 X
Arr:a
10,874
= 2,125
TOTAL HOURLY HEAT LOSS FOR ROOM 12,999
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 2
Floor Area 712.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Pitched Roof w/R-13
712.0
00236
46
771
R-21 Wall (W.21.2x6.16)
598.8
0.0690
46
7.901
Casement .5126
16.2
0.5000
46
373
Patio Door. 391.32
120.0
0.3900
46
2,153
Slab -On -Grade
perim = 71.0
0.7300
46
2,384
*R-0 Interior Waft
480.0
0.3560
0
0
Items shown with an asterisk (*) denote conduction
Infiltration[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 712 X
Area
another room
10.00 X 0.313
Height ACH
Page Total
/ 60 J X
AT
7,582
= 1,Si6
TOTAL HOURLY HEAT LOSS FOR ROOM 9,398
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bar
Floor Area 343.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4T OF
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
_
46
Btu/hr
R-38 Pitched Roof w/ R-13
343.0
0.0236
46
372
R-21 Wall (W21.2x6.16)
12.5
0.0690
46
40
Fixed .39131
137.5
0.3900
46
2,467
Slab -On -Grade
perim = 14.0
0.7300
46
470
"R-0 Interior Wall
540.0
0.3560
0
0
X
Page Total
/ 60 J X
AT
Items shown with an asterisk (`) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 343 X
Area
another room
12.00 X 0.261
Height ACH
3,348
= 875
TOTAL HOURLY HEAT LOSS FOR ROOM 4,223
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Living/Foyer
Floor Area 1,425.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
223
AT OF
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 twitched Roof w1 R-13
1,425.0
0.0236
0.0690
46
46
1,544
R-21 Waft (W.21.2x6.16)
129.3
277.2
410
Fixed .391..31
0.3900
46
4,973
Custom Entry.921, 59
69.3
0.9200
46
2,933
Patio Door.391.32
572.0
0.3900
46
10.262
Slab -On -Grade
perim = 125.0
0.7300
46
4.198
'R-0 Interior Wall
875.0
0.3560
0
0
'R-13 Walt
300.0
0.1020
0
0
Items shown with an aster:sk (*) denote conduction
Infiltration:[ E1 J X 1.064
Sd1C-.0L1lG Air Sensible
Fraction
through an interior surface
X 1,425 X
Area
another room
14.00 X 0
Height AGH
Page Total
/ 60 J X �
AT
24.319
= 3,635
27,954
TOTAL HOURLY HEAT LOSS FOR ROOM
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Flex
Floor Area 609.00 ft2
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
0.0236
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
c
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Pitched Roof w/R-13
609.0
43.4
46
660
R-21 Wall (W.21.2x6.16)
0.0690
46
138
Patio Door.391..32
226.6
0.3900
46
4,065
Slab -On -Grade
perim = 23.0
0.7300
46
772
*R-0 Interior Wall
635.0
0.3560
0
0
Items shown with an asterisk (*) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 609 X
Area
another room
12.00 X 0.261
Height ACH
Page Total
/ 60 J X
AT
5,635
= 1,553
TOTAL HOURLY HEAT LOSS FOR ROOM 7,188
ROOM HEATING PEAK LOADS
Project Name Date
Custom Residence -The Madison Club 51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Rec./Media
Floor Area 956.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X _
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4T OF
=
c
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Pitched Roof w/R-13
956.0
0.0236
46
1.036
R-21 Waif (W.21.2x6.16)
306.0
0.0690
46
971
Casement .5/.26
132.0
0.5000
46
3,036
Patio Door .391..32
264.0
0.3900
46
4,736
Slab -On -Grade
perim = 76.0
0.7300
46
2,552
'R-0 Interior Wall
280.0
0.3560
0
0
Page Total
/ 60 J X
AT
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X L 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 956 X
Area
another room
12.00 X 0.261
Heigh[ ACH
12,331
2,439
TOTAL HOURLY HEAT LOSS FOR ROOM 14,770
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom 3
Floor Area 777.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT OF
=
=
=
c
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Pitched Roof w/ R-13
777.0
0.0236
46
642
R-21 Wall (W 21.2x6.16)
645.5
0.0690
46
2,049
Casement .51..26
95.5
0.5000
46
2,197
Wood Door
24.0
0.5000
46
552
Slab -an -Grade
perim = 71.0
0.7300
46
2,384
*R-0 Inferior Wall
330.0
0.3560
0
0
another room
10.00 X 0.313�
Height ACH
Items shown with an asterisk (*) denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 777 X
Area
Page Total
/ 60 X
AT
8.023
TOTAL HOURLY HEAT LOSS FOR ROOM 10,005
ROOM HEATING PEAK LOADS
Project Name Date
Custom Residence -The Madison Club 5/3/2019
ROOM INFORMATION DESIGN CONDITIONS
Room Name Bedroom 4 Time of Peak Jan 1 AM
Floor Area 466.00 ft2 Outdoor Dry Bulb Temperature 26 °F
Indoor Dry Bulb Temperature 72 OF
Conduction Area
R-38 Pitched Roof w/R-13 466.0 X
R-21 Wall (W.21.2x6 16) 418.3 X
Swinging Door .51126 5.4 X
Casement .5/. 26 6.3 X
Slab -On -Grade perim = 14.0 X
*R-0 Interior Wall 370.0 X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (*) denote conduction through an interior surface to another room
U-Value
AT °F
X
46
=
X
46
=
X
46
=
X
46
=
X
46
=
X
0
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X
=
X =
Page Total
Btu/hr
505
1,328
127
145
470
0
1 2,5741
Infiltration:[ l 1.00 X 1.064 X 466 X 10.00 X 0.313 / 60 J X , 461 =
Schedule Air Sensible Area Ceiling Height ACH i
Fraction
1,189
TOTAL HOURLY HEAT LOSS FOR ROOM 3.763
ROOM HEATING PEAK LOADS
Project Name
Custom Residence -The Madison Club
Date
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Guest
Floor Area 1,631.00 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U-Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT °F
=
=
=
c
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Pitched Roof w/ R-13
1,631,0
0.0236
46
1,767
R-21 Wad (W.21.2x6.16)
1,687.7
0.0690
46
5,357
Patio Door .391.32
116.3
0.3900
46
2., 086
Swinging Door.511,,26
24.0
0.5100
46
563
Casement .5/.26
134.0
0.5000
46
3,082
Slab -On -Grade
perim = 184.0
0.7300
46
6,179
.R-0 Interior Wall
5.0
0.3560
0
0
through an interior surface
X 1,631 X
Area
Items shown with an asterisk (") denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
another room
12.00 X 0.261
Height ACH
Page Total
/ 60 ] X!
AT
19.034
_ a. r60
TOTAL HOURLY HEAT LOSS FOR ROOM
23,194
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Master Bedroom
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,398.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Pitched Roof wI R-13
(1/10 1,398.0 X 0.0236
X
56.0 =
1,844
R-21 Wall (W21.2x6.16)
(N) 561.1 X 0.0690
X
23.0 =
890
R-21 Wall (W.21.2x6.16)
(E) 45.0 X 0.0690
X
33.0 =
102
R-21 Wall (W..21.2x6.16)
(S) 210.0 X 0.0690
X
26.0 =
377
R-21 Wall (W.21.2x6.16)
(Vl9 207.0 X 0.0690
X
33.0 =
471
'R 0 Inferior Wall
120.0 X 03560
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page Total
3, 685
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
3X5
(N) 0.0 X 19.3 +
15.0
X 19.3 =
290
3X5
(N) 0.0 X 19.3 +
15.0
X 19.3 =
290
2.5X15
(N) 0.0 X 19.6 +
6.3
X 19.6 =
124
2.5X10
(N) 0.0 X 19.3 +
25.0
X 19.3 =
483
2.5X70
(N) 0.0 X 19.3 +
25.0
X 19.3 =
483
2.5X2, 5
(N) 0.0 X 19.6 +
6.3
X 19.6 =
124
2.5X2.5
(N) 0.0 X 19.6 +
6.3
X 19.6 =
124
6Xi 1
(S) 66.0 X 19.7 +
0.0
X 19.7 =
1,299
18X11
(Vlo 113.4 X 19.7 +
84.6
X 38.7 =
5,503
Page Total
8,79
Internal Gain
Btu/hr
Occupants
4.2 Occupants X 245
Btuh/occ.
_EA
ui E ment
1,398 Floor Area X 0.50
w/sgft
W
Infiltration: 1.064
X 0.88 X 75.25 X 36
2,548
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
18,363
Latent Gain
Btu/hr
Occupants
4.2 Occupants X F_ 155
Btuh/occ.
_
650
Infiltration: 4,771
X 0.88 X 7525 X 000344 =
1,091
Air Latent
CFM ELA 4W
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
650
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Kitchen & Utility
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,297.00 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Pitched Roof w1 R-13 W 1,297.0 X 0. 0236 X
56.0 =
1,711
R-21 Well (W.21.2x6.16) (N) 145.7 X 0.0690 X
23.0 =
231
R-21 Wall (W,21.2x6.16) 143.0 X 0.0690 X
33.0 =
326
'R-0 Interior Wall 380.0 X 0.3560 X
0.0 =
0
'R-13 Wall 300.0 X 0.1020 X
0.0 =
0
X X
=
X X
=
X X
=
X X
=
Page Total
Z267
Items shown with an asterisk (") denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
4X4.5 (N) 0.0 X 19.6 + 18.0
X 19.6 =
354
4X4.5 (N) 0.0 X 19.6 + 6.3
X 19.6 =
124
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
477
Internal Gain
Btu/hr
Occupants X 245 Btuh/occ.
Occupants LL12
=
953E
ui ment Floor Area X 0.50 w/sgft
=
2,213
Infiltration: 1.064 X 0.88 X 69.82 X 36 =
2,364
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
8,275
Gain
Btu/hr
_Latent
Occupants 39 Occupants X 155� Btuh/occ.
=
603
Infiltration: 4,771 X 0.88 X 69.82� X 0.00344
Air Latent CFM ELA 11N
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
603
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
i 51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Office
Outdoor Dry Bulb Temperature
112 OF
Floor Area 833.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
R•38 Pitched Roof w1 R-13 (W) 833.0 X 0.0236
X
56.0 =
1,099
R-21 Wall (W 21.2x6.16) (N) 6.7 X 0.0690
X
23.0 =
11
R-21 Walt (W.21.2x6.16) (E) 207.7 X 0.0690
X
33.0 =
473
R-21 Wall (W 21.2x6.16) (S) 287.4 X 0.0690
X
26.0 =
516
R-21 Wall (W.21.2x6.16) W 40.0 X 0.0690
X
33.0 =
91
"R-0 Inferior Wall 520.0 X 0.3560
X
0.0 =
0
X
X
=
X
X
X
X
-
Page Total
2,189
Items shown with an asterisk (*) denote conduction through an interior surface to another room
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF
Area
GLF
Btu/hr
10.3X11 (N) 0.0 X 19.7 +
113.3
X 19.7 =
2,229
i 0.3X11 (E) 113.3 X 19.7 +
0.0
X 38.7 ❑
2,229
6X11 (S) 0.0 X 19.3 +
66.0
X 19.4 ❑
1,279
2.7X2.7 (S) 7.3 X 19.6 +
0.0
X 19.7 =
143
3X4 (S) 12.0 X 19.3 +
0.0
X 19.4 =
232
2.7X2.7 (S) 7.3 X 19.6 +
0.0
X 19.7 =
143
X +
X =
X +
X =
X +
X =
Page Total
6,256
Internal Gain
Btu/hr
Occupants _1 2.5 Occupants X 245
gtuh/occ.
=
Equipment 833 Floor Area X 0.50
w/sgft
=L:1
Infiltration: 1.064 X 0.88� X 44.84 X 36 =
1.518
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
11,996
Latent Gain
Btu/hr
Occupants 2.5 Occupants X 155
gtuh/occ.
=
387
Infiltration: 4,771 X F 088 X 44.84 X 0.00344] =
650
Air Latent CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
387
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 2
Outdoor Dry Bulb Temperature
112 OF
Floor Area
712.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 76 OF
1 Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Pitched Root wl R-13
(W) 712.0 X 0.0236
X
56.0 =
939
R-21 Walt (W 21.2x6.16)
(N) 95.0 X 0.0690
X
23.0 =
151
R-21 Wall (W.21.2x6.16)
(E) 80.0 X 0.0690
X
33.0 =
182
R-21 Wall (W.21.2x6.16)
(S) 303.8 X 0.0690
X
26.0 =
545
R-21 Wall (W.21.2x6.16)
(W) 120.0 X 0.0690
X
33.0 =
273
'R-0 Interior Wall
480.0 X 0.3560
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page Total
2,090
Items shown with an asterisk (*)
denote conduction through an interior surface to another room
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
2X2.7
(S) 0.0 X 19.6 +
5.4
X 19.7 =
106
4X2.7
(S) 0.0 X 19.6 +
10.8
X 19.7 =
213
12XIO
(W) 120.0 X 19.7 +
0.0
X 38.7 =
2,361
X +
X -
X +
X -
X +
X -
X +
X -
X +
X =
X +
_
X =
Page Total
2,680
Internal Gain
Btu/hr
Occupants
21 Occupants X 245
Btuh/occ.
=
523
E ui menf
712 Floor Area X 0.501
w/sgft
Infiltration: 1.064
X 0.88 X 38.33 X 36 =
1,298
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,806
Latent Gain
Btu/hr
Occupants
2.1 Occupants X 155
Btuh/occ.
-
331
Infiltration: 4,771
X 0.881 X 38.33 X 0.00344 =
555
Air Latent
CFM FLA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
331
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bar
Outdoor Dry Bulb Temperature
112 OF
Floor Area 343.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
I Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD�
Btu/hr
R-38 Pitched Roof w1 R-13 (W) 343.0 X 0.0236
X
56.0 =
452
R-21 Wall (W.21.2x6.16) (E) 12.5 X 0.0690
X
33.0 =
28
*R--0 Interior Wall 540.0 X 0.3560
X
0.0 =
a
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
481
Items shown with an asterisk (*) denote conduction through an interior surface to another room
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
12.5X11 (E) 137.5 X 19.3 +
0.0
X 37.7 =
2,654
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
2,654
Internal Gain
Btu/hr
Occupants 1.0 Occupants X 245
Btuh/occ.
—
252
Equipment 343 Floor Area X 0.501
w/sgft
Infiltration: 1.064 X 0.88 X 18.46 X 36 =
625
Air Sens! We CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
4,598
Latent Gain
Btu/hr
Occupants 1.0 Occupants X 1551
Btuh/occ.
=
159
Infiltration: 4,771 X o.88 X 18.46! X 0 00344 -
268
Air Latent GFM ELA iW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
159
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Living/Foyer
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,425.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF1
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Pitched Roof wI R-13
(Kq 1,425.0 X 0.0236
X
56.0 =
1.879
R-21 Wall (W21.2x6.16)
(E) 69.3 X 0.0690
X
33.0 =
158
R-21 Wall (W.21.2x6.16)
(W) 60.0 X 0.0690
X
33.0 =
137
R 0 Interior Wall
875.0 X 0.3560
X
0.0 =
0
'R 13 Wall
300.0 X 0.1020
X
0.0 =
0
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
2,174
Items shown with an asterisk (*)
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
12.6X11
(E) 138.6 X 19.3 +
0.0
X 37.7 =
Z675
6.3X11
(E) 69.3 X 40.3 +
0.0
X 75.3 =
2,792
12.6X71
(E) 138.6 X 19.3 +
0.0
X 37.7 =
2,675
44X13
W 572.0 X 19.7 +
0.0
X 38.7 =
11,254
X +
X =
X +
X =
X +
X =
X +
X =
X +
X.
Page Total
19.397
Internal Gain
Btu/hr
Occupants
Occupants X 245
N142
Btuh/occ.
=
1,047
E ui ment
Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.88 X 76.71I X 36
Air Sensible
_
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
27,647
Latent Gain
Btu/hr
Occupants
4,3 Occupants X � 155
Btuh/occ.
=
663
Infiltration: 4,771
X 0.88 X 76.71 X 0.00344 =
7.992
Air Latent
CFM FLA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
663
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Flex
Outdoor Dry Bulb Temperature
112 OF
Floor Area 609.00 ftZ
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 °F
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
R-36 Pitched Roof wI R-13 (WJ 609.0 X 0.0236 X
56.0 =
803
R-21 Wall (W.21.24.16) (E) 24.7 X 0.0690 X
33.0 =
56
R-21 Wall (W.21.2x6.16) (S) 18.7 X 0.0690 X
26.0 =
34
'R-0 Interior Wall 635.0 X 0.3560 X
0.0 =
0
X X
=
X X
=
X X
=
X X
=
X X
=
Page Total
893
Items shown with an asterisk (*) denote conduction through an interior surface to another room
1 Cooling Load Temperature Difference (CLTD)
Shaded Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
10.3X11 (E) 64.9 X 19.7 + 484
X 38.7 =
3,149
10.3X11 (S) 113.3 X 19.7 + 0.0
X 19.7 =
2,229
X +
X —
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total-37
Internal Gain
Btu/hr
Occupants 1.8 Occupants X 245. Btuh/occ.
=
448
Equipment 609 Floor Area X 0.50I. w/sgft
=
1,039
Infiltration: 1.064 X 0.88 X 32.78 X 36 =
f,110
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
8,868
Latent Gain
Btu/hr
_
Occupants 1•8 Occupants X � 1551 gtuh/occ.
—
283
Infiltration: 4,771 X 0.88 X 32.78 X 0.00344 =
475
Air Latent CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
283
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
1 51312019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Rec./Media
Outdoor Dry Bulb Temperature
112 OF
Floor Area 956.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor D Bulb Temperature 76 6F
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U-Factor
CLTD'
Btu/hr
R 38 Pitched Roof wl R-13 (W) 956 0 X 0.0236
X
56.0 =
1,261
R-21 Wall (W.21,2x6.16) (N) 192.0 X 0.0690
X
23.0 =
305
R-21 Wall (W.21.2x6.16) (S) 60.0 X 0.0690
X
26.0 =
108
R-21 Wall (W.21.2x6,16) 54.0 X 0.0690
X
33.0 =
123
'R--0 Interior Wall 280.0 X 0.3560
X
0.0 =
❑
X
X
=
X
X
=
i
X
X
X
X
_
Page Total
1. 796
Items shown with an asterisk (') denote conduction through an interior surface to another room
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
6X11 (N) 0.0 X 19.6 +
66.0
X 19.6 =
1,297
6X11 (N) 0.0 X 19.6 +
66.0
X 19.6 =
1,297
24X11 (S) 264.0 X 19.7 +
0.0
X 19.7 =
5,194
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
_
Page Total
7..78
Internal Gain
Btu/hr
Occupants 2.9 Occupants X 245
Btuh/occ.
_
703
Equipment 956 Floor Area X 0.50
w/sgft
1,631
Infiltration: 1.064 X 0.88 X 51.46 X 36 =
1,742
Air Sensible CFM ELA 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
13,660
Latent Gain
Btu/hr
Occupants 2.9 Occupants X 155�
Btuh/occ.
..
445
Infiltration: 4,771 X 0.88 X 51.46 X 0.00344 =
746
Air Latent CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
445
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 3
Outdoor Dry Bulb Temperature
112 OF
Floor Area
777.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R-38 Pitched Roof w/ R-13
(W) 777.0 X 0.0236
X
56.0 =
1,025
R-21 Wall (W 21.2x6.16)
(N) 12.0 X 0.0690
X
23.0 =
19
R-21 Wall (W 21.2x6.16)
(E) 256.0 X 0.0690
X
33.0 =
583
Wood Door
(E) 24.0 X 0.5000
X
33.0 =
396
R-21 Wall (W 21.2x6.16)
(S) 262.5 X 0,0690
X
26.0 =
471
R-21 Wall (W.21.2x6.16)
(W) 115.0 X 0.0690
X
33.0 =
262
'R-0 lnivior Walf
330.0 X 0.3560
X
0.0 =
0
X
X
=
X L
X
=
Page Total
2.755
Items shown with an asterisk (*)
denote conduction through an interior surface to another room
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
6X8
(N) 0.0 X 19.6 +
48.0
X 19.6 =
943
2.5X3
(S) 0.0 X 19.6 +
7.5
X 19.7 =
148
8X5
(S) 0.0 X 19.6 +
40.0
X 19.7 =
788
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
1,879
Internal Gain
Btu/hr
Occupants
2.3 Occupants X 245
Btuh/occ.
=
571
Equipment
777 Floor Area X 0.50I
w/sgft
Infiltration: 1.064
X 0.88 X 41.82 X 36 =
1,416
Air Sensible
CFM Et.A 4T
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
7,948
Latent Gain
Btu/hr
Occupants
12.3 Occupants X 155
Btuh/occ.
=
361
Infiltration: 4,771
X 0.88 X 41.82 X 0.00344 =
606
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
361
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The
Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Bedroom 4
Outdoor Dry Bulb Temperature
112 OF
Floor Area
466.00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 °F
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor CLTD'
Btu/hr
R-38 Pitched Roof wl R-13
466.0 X 0.0236 X
56.0 =
615
R-21 Wall (W.21.2x6.16)
(N) 228.3 X 0.0690 X
23.0 =
362
R-21 Wag (W.21.2x6.16)
(E) 190.0 X 0.0690 X
33.0 =
433
'R-0 Interior Wall
370.0 x 0.3560 X
0.0 =
0
x x
=
x x
=
x x
=
x x
=
x x
=
Page Total
7,470
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
8X5
(N) 0.0 x 19.8 + 5.4
X 19.8 =
107
2.5X3
(N) 0.0 X 19.6 + 6.3
X 19.6 =
124
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
231
Internal Gain
Btu/hr
Occupants
1 4 Occupants X 2451 Btuh/occ.
=
343
Equipment
466 Floor Area X 0.50I w/sgft
=
795
Infiltration: 1.064
x 0.88 x 25.08 x 36 =
849
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
3,627
Latent Gain
Btu/hr
Occupants
1 4 Occupants X 155 Btuh/occ.
=
217
Infiltration: 4,771
X 0.88 X 25.08 X 0.00344 =
364
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT
HEAT GAIN FOR ROOM
217
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
Custom Residence -The
Madison Club
5/3/2019
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Guest
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1, 63 1. 00 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U-Factor
CLTD'
Btu/hr
R 38 Pitched Roof wl R-13
1,631.0 X 0,0236
X
56.0 =
2,151
R-21 Well (W.21.2x6.16)
(N) 418.0 X 0.0690
X
23.0 =
663
R-21 Wall (W.21. 2x6.16)
(E) 354.8 X 0,0690
X
33.0 =
808
R-21 Wall (W 21.2x6.16)
(S) 440.0 X 0.0690
X
26.0 =
789
R-21 Wall (W21.2x6.16)
474.9 X a0690
X
33.0 =
1,081
R-0 Interior Wall
5.0 X a3560
X
0.0 =
0
X
X
=
X
X
=
X
X
=
Page
Total
5.493
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF
Area
GLF
Btu/hr
10X11
(N) 0.0 X 19.7 +
110.0
X 19.7 =
2,164
3X8
(E) 0.0 X 19.8 +
24.0
X 35.3 =
847
SX8
(E) 0.0 X 19.6 +
64.0
X 35.1 =
2,245
6X2.7
(E) 0.0 X 19.6 +
16.2
X 35.1 =
566
8X5
(S) 0.0 X 19.6 +
40.0
X 19.7 =
788
2.5X3
(W) 0.0 X 19.6 +
7.5
X 35.1 =
263
3.5X4.5
(M 0.0 X 19.6 +
6.3
X 35.11 =
221
15X11
(W) 6.3 X 19.7 +
0.0
X 38.7 =
124
X +
X =
Page Total
7,221
Internal Gain
Btu/hr
Occupants
4.9 Occupants X 245
Btuh/occ.
=
1.1.99
Equipment
1,631 Floor Area X 0.50
w/sgft
=
2,783
Infiltration: 1.064
X 0.88 X 87.79 X 36 =
2,972
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
19,669
Latent Gain
Btu/hr
Occupants
4 9 Occupants X 1551
Btuh/occ.
=
758
Infiltration: 4,771
X 0.88 X 87 791 X 0.00344
Air Latent
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
758
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribd16x
CF1 R-PRF-01
Page 1 of 16
GENERAL INFORMATION
01
Project Name
Madison Lot 18B
02
Calculation Description
Title 24 Analysis
03
Project Location
Lot 18-13, 52355 Meriwether
04
City
La Quinta
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.1 (1149)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
90
12
Project Scope
Newly Constructed
13
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft)
10447
15
Number of Zones
11
16
Slab Area (ft2)
10447
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2)
n/a
21
Glazing Percentage (%)
27.8%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.51
5.09
-2.58
-102.8%
Space Cooling
72.33
69.68
2.65
3.7%
IAQ Ventilation
0.69
0.69
0.00
0.0%
Water Heating
j 1.57
1.36
0.21
13.4%
Photovoltaic
0.00
0.00
-----Compliance
Enet"CATY
gy Tot
10
76.82
0.28
0.4%
REVIEWED FUH
CODE
COMPLIANCE
DATE S 14 ' 1018Y
t'aroes Zo 11 ' o q y �
Registration Number: 219-P010033172B-000.000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2019-05-03 11:13:38
Report Version - CF1 R-01162019-1149
RECEIVED
MAY 062019
M*UWA CaICERTS inc.
DESIGN -03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B
Calculation Description: Title 24 Analysis
Calculation Date/Time: 11:06, Fri, May 03, 2019
Input File Name: Madison Lot 18B-Radford-19.ribd16x
CF1 R-PRF-01
Page 2 of 16
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out' its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery Final Proposed EDR
44.8
44.7
0.0 44.7
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV)
renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified.
[Notes:xcess
PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• -- None --
Registration Number: 219-PO10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
[a] AIza;a:7;Eli I
Page 3 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Madison Lot 18B
10447
1
6
11
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master
Conditioned
HVAC Zone 31
1398
11.6
DHW Sys 1
n/a
Kitchen/Utility
Conditioned
HVAC Zone 31
1297
11.2
DHW Sys 1
n/a
Office
Conditioned
HVAC Zone 12
833
12
DHW Sys 1
n/a
Bedroom 2
Conditioned
HVAC Zone 12
712
10
DHW Sys 1
n/a
Bar
Conditioned
HVAC Zone 12
343
12
DHW Sys 1
n/a
Living/Foyer
Conditioned
HVAC Zone 23
1425
14
DHW Sys 1
n/a
Flex
Conditioned
HVAC Zone 23
609
12
DHW Sys 1
n/a
Rec Room
Conditioned
HVAC Zone 44
956
12
DHW Sys 1
n/a
Bedroom 3/Hall
Conditioned
HVAC Zone 44
777
10
DHW Sys 1
n/a
Bedroom 4
Conditioned
HVAC Zone 44
466
10
DHW Sys 1
n/a
Guest
Conditioned
HVAC Zone 55
1631
12
DHW Sys 1
n/a
Registration Number: 219-Po10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 4 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Master
R-21 Wall (W.21.2x6.16)
0
Right
660
98.9
90
E Wall
Master
R-21 Wall (W.21.2x6.16)
90
Front
45
0
90
S Wall
Master
R-21 Wall (W.21.2x6.16)
180
Left
276
66
90
W Wall
Master
R-21 Wall (W.21.2x6.16)
270
Back
405
198
90
Interior Surface
Master»Kitchen/Utility
R-0 Interior Wall
n/a
n/a
120
0
n/a
Roof -pitched
Master
R-38 Pitched Roof w/ R-1
n/a
n/a
1398
n/a
n/a
N Wall 2
Kitchen/Utility
R-21 Wall (W.21.2x6.16)
0
Right
170
24.3
90
W Wall 2
Kitchen/Utility
R-21 Wall (W.21.2x6.16)
270
Back
143
0
90
Interior Surface 2
Kitchen/Utility»Flex
R-0 Interior Wall
n/a
n/a
260
0
n/a
Interior Surface 3
Kitchen/Utility»Master
R-0 Interior Wall
n/a
n/a
120
0
n/a
Interior Surface 4
Kitchen/Utility»Living/Foyer
R-13 Wall
n/a
n/a
300
0
n/a
Roof -pitched 2
Kitchen/Utility
R-38 Pitched Roof w/ R-1
n/a
n/a
1297
n/a
n/a
N Wall 3
Office
R-21 Wall (W.21.2x6.16)
0
Right
120
113.3
90
E Wall 2
Office
R-21 Wall (W.21.2x6.16)
90
Front
321
113.3
90
S Wall 2
Office
R-21 Wall (W.21.2x6.16)
180
Left
380
92.5946
90
W Wall 3
Office
R-21 Wall (W.21.2x6.16)
270
Back
40
0
90
Interior Surface 5
Office»Bar
R-0 Interior Wall
n/a
n/a
200
0
n/a
Interior Surface 6
Office»Bedroom 2
R-0 Interior Wall
n/a
n/a
320
0
n/a
Roof -pitched 3
Office
R-38 Pitched Roof w/ R-1
n/a
n/a
833
n/a
n/a
N Wall 4
Bedroom 2
R-21 Wall (W.21.2x6.16)
0
Right
95
0
90
E Wall 3
Bedroom 2
R-21 Wall (W.21.2x6.16)
90
Front
80
0
90
S Wall 3
Bedroom 2
R-21 Wall (W.21.24.16)
180
Left
320
16.2
90
W Wall 4
Bedroom 2
R-21 Wall (W.21.2x6.16)
270
Back
240
120
90
Interior Surface 7
Bedroom 2»Living/Foyer
R-0 Interior Wall
n/a
n/a
160
0
n/a
Interior Surface 8
Bedroom 2»Office
R-0 Interior Wall
n/a
n/a
320
0
n/a
Roof -pitched 4
Bedroom 2
R-38 Pitched Roof w/ R-1
n/a
n/a
712
n/a
n/a
E Wall 4
Bar
R-21 Wall (W.21.2x6.16)
90
Front
150
137.5
90
Interior Surface 9
Bar
R-0 Interior Wall
n/a
n/a
500
0
n/a
Interior Surface 10
Bar»Office
R-0 Interior Wall
n/a
n/a
200
0
n/a
Interior Surface 11
Bar»Living/Foyer
R-0 Interior Wall
n/a
n/a
340
0
n/a
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 5 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 1813-Radford-19.ribdl6x
Roof -pitched 5
Bar
R-38 Pitched Roof w/ R-1
n/a
n/a
343
n/a
n/a
E Wall 5
Living/Foyer
R-21 Wall (W21.2x6.16)
90
Front
415.8
346.522
90
W Wall 5
Living/Foyer
R-21 Wall (W.21.2x6.16)
270
Back
632
572
90
Interior Surface 12
Living/Foyer»Bedroom 2
R-0 Interior Wall
n/a
n/a
160
0
n/a
Interior Surface 13
Living/Foyer»Bar
R-0 Interior Wall
n/a
n/a
340
0
n/a
Interior Surface 14
Living/Foyer»Kitchen/Utility
R-13 Wall
n/a
n/a
300
0
n/a
Interior Surface 15
Living/Foyer»Flex
R-0 Interior Wall
n/a
n/a
375
0
n/a
Roof -pitched 6
Living/Foyer
R-38 Pitched Roof w/ R-1
n/a
n/a
1425
n/a
n/a
E Wall 6
Flex
R-21 Wall (W.21.2x6.16)
90
Front
138
113.3
90
S Wall 4
Flex
R-21 Wall (W21.2x6.16)
180
Left
132
113.3
90
Interior Surface 16
Flex»Living/Foyer
R-0 Interior Wall
n/a
n/a
375
0
n/a
Interior Surface 17
Flex>>Kitchen/Utility
R-0 Interior Wall
n/a
n/a
260
0
n/a
Roof -pitched 7
Flex
R-38 Pitched Roof w/ R-1
n/a
n/a
609
n/a
n/a
N Wall 5
Rec Room
R-21 Wall (W.21.2x6.16)
0
Right
324
132
90
S Wall 5
Rec Room
R-21 Wall (W.21.2x6.16)
180
Left
324
264
90
W Wall 6
Rec Room
R-21 Wall (W.21.2x6.16)
270
Back
54
0
90
Interior Surface 18
Rec Room»Bedroom 3/Hall
R-0 Interior Wall
n/a
n/a
120
0
n/a
Interior Surface 19
Rec Room»Bedroom 4
R-0 Interior Wall
n/a
n/a
160
0
n/a
Roof -pitched 8
Rec Room
R-38 Pitched Roof w/ R-1
n/a
n/a
956
n/a
n/a
N Wall 6
Bedroom 3/Hall
R-21 Wall (W.21.2x6.16)
0
Right
60
48
90
E Wall 7
Bedroom 3/Hall
R-21 Wall (W.21.2x6.16)
90
Front
280
24
90
S Wall 6
Bedroom 3/Hall
R-21 Wall (W.21.2x6.16)
180
Left
310
47.5
90
W Wall 7
Bedroom 3/Hall
R-21 Wall (W 21.2x6.16)
270
Back
115
0
90
Interior Surface 20
Bedroom 3/Hall»Bedroom 4
R-0 Interior Wall
n/a
n/a
210
0
n/a
Interior Surface 21
Bedroom 3/Hall»Rec Room
R-0 Interior Wall
n/a
n/a
120
0
n/a
Roof -pitched 9
Bedroom 3/Hall
R-38 Pitched Roof w/ R-1
n/a
n/a
777
n/a
n/a
N Wall 7
Bedroom 4
R-21 Wall (W.21.2x6.16)
0
Right
240
11.7
90
E Wall 8
Bedroom 4
R-21 Wall (W.21.2x6.16)
90
Front
190
0
90
Interior Surface 22
Bedroom 4—Bedroom 3/Hall
R-0 Interior Wall
n/a
n/a
210
0
n/a
Interior Surface 23
Bedroom 4»Rec Room
R-0 Interior Wall
n/a
n/a
160
0
n/a
Roof -pitched 10
Bedroom 4
R-38 Pitched Roof w/ R-1
n/a
n/a
466
n/a
n/a
N Wall 8
Guest
R-21 Wall (W.21.2x6.16)
0
Right
528
110
90
E Wall 9
Guest
R-21 Wall (W 21.2x6.16)
90
Front
459
104.2
90
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration DatefTime: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 6 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
S Wall 7
Guest
R-21 Wall (W.21.2x6.16)
180
Left
480
40
90
W Wall 8
Guest
R-21 Wall (W.21.2x6.16)
270
Back
495
20.07
90
Interior Surface 24
Guest»Living/Foyer
R-0 Interior Wall
n/a
n/a
5
0
n/a
Roof -pitched 11
Guest
R-38 Pitched Roof w/ R-1
n/a
n/a
1631
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master
Attic RoofMaster
Ventilated
3
0.1
0.85
Yes
No
Attic Kitchen/Utility
Attic RoofKitchen/Utility
Ventilated
3
0.1
0.85
Yes
No
Attic Office
Attic RoofOffice
Ventilated
3
0.1
0.85
Yes
No
Attic Bedroom 2
Attic RoofBedroom 2
Ventilated
3
0.1
0.85
Yes
No
Attic Bar
Attic RoofBar
Ventilated
3
0.1
0.85
Yes
No
Attic Living/Foyer
Attic RoofLiving/Foyer
Ventilated
3
0.1
0.85
Yes
No
Attic Flex
Attic RoofFlex
Ventilated
3
0.1
0.85
Yes
No
Attic Rec Room
Attic RoofRec Room
Ventilated
3
0.1
0.85
Yes
No
Attic Bedroom 3/Hall
Attic RoofBedroom 3/Hall
Ventilated
3
0.1
0.85
Yes
No
Attic Bedroom 4
Attic RoofBedroom 4
Ventilated
3
0.1
0.85
Yes
No
Attic Guest
Attic RoofGuest
Ventilated
3
0.1
0.85
Yes
No
Registration Number: 219-Po10033172B-000-000-0000000-0000 Registration DatefTime: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 7 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
p
Area
(ft)
U-factor
SHGC
Exterior Shading
3X5
Window
N Wall (Right-0)
----
-
1
15.0
0.39
0.31
Insect Screen (default)
3X5 2
Window
N Wall (Right-0)
1
15.0
0.39
0.31
Insect Screen (default)
2.5X2.5
Window
N Wall (Right-0)
1
6.3
0.50
0.26
Insect Screen (default)
2.5X10
Window
N Wall (Right-0)
----
--
1
25.0
0.39
0.31
Insect Screen (default)
2.5X10 2
Window
N Wall (Right-0)
--
-
1
25.0
0.39
0.31
Insect Screen (default)
2.5X2.5 2
Window
N Wall (Right-0)
----
-
1
6.3
0.50
0.26
Insect Screen (default)
2.5X2.5 3
Window
N Wall (Right-0)
-
----
1
6.3
0.50
0.26
Insect Screen (default)
6X11
Window
S Wall (Left-180)
6.0
11.0
1
66.0
0.39
0.32
Insect Screen (default)
18X11
Window
W Wall (Back-270)
18.0
11.0
1
198.0
0.39
0.32
Insect Screen (default)
4X4.5
Window
N Wall 2 (Right-0)
----
-
1
18.0
0.50
0.26
Insect Screen (default)
4X4.5 2
Window
N Wall 2 (Right-0)
----
-----
1
6.3
0.50
0.26
Insect Screen (default)
10.3X11
Window
N Wall 3 (Right-0)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
10.3X11 2
Window
E Wall 2 (Front-90)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
6X11 2
Window
S Wall 2 (Left-180)
----
--
1
66.0
0.39
0.31
Insect Screen (default)
2.7X2.7
Window
S Wall 2 (Left-180)
2.7
2.7
1.001
7.3
0.50
0.26
Insect Screen (default)
3X4
Window
S Wall 2 (Left-180)
3.0
4.0
1
12.0
0.39
0.31
Insect Screen (default)
2.7X2.7 2
Window
S Wall 2 (Left-180)
2.7
2.7
1.001
7.3
0.50
0.26
Insect Screen (default)
2X2.7
Window
S Wall 3 (Left-180)
---
--
1
5.4
0.50
0.26
Insect Screen (default)
4X2.7
Window
S Wall 3 (Left-180)
----
--
1
10.8
0.50
0.26
Insect Screen (default)
12X10
Window
W Wall 4 (Back-270)
12.0
10.0
1
1200.
0.39
0.32
Insect Screen (default)
12.5X11
Window
E Wall 4 (Front-90)
12.5
11.0
1
137.5
0.39
0.31
Insect Screen (default)
12.6X11
Window
E Wall 5 (Front-90)
19.0
11.0
0.663
138.6
0.39
0.31
Insect Screen (default)
6.3X11
Window
E Wall 5 (Front-90)
19.0
11.0
0.332
69.4
0.92
0.59
Insect Screen (default)
12.6X11 2
Window
E Wall 5 (Front-90)
19.0
11.0
0.663
138.6
0.39
0.31
Insect Screen (default)
44X13
Window
W Wall 5 (Back-270)
44.0
13.0
1
572.0
0.39
0.32
Insect Screen (default)
10.3X11 3
Window
E Wall 6 (Front-90)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
10.3X11 4
Window
S Wall 4 (Left-180)
10.3
11.0
1
113.3
0.39
0.32
Insect Screen (default)
6X11 3
Window
N Wall 5 (Right-0)
----
----
1
66.0
0.50 1
0.26
Insect Screen (default)
6X11 4
Window
N Wall 5 (Right-0)
---- I
----
1
66.0
0.50
0.26
Insect Screen (default)
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation DatelTime: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 8 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
24X11
Window
S Wall 5 (Left-180)
24.0
11.0
1
264.0
0.39
0.32
Insect Screen (default)
6X8
Window
N Wall 6 (Right-0)
----
----
1
48.0
0.50
0.26
Insect Screen (default)
2.5X3
Window
S Wall 6 (Left-180)
----
----
1
7.5
0.50
0.26
Insect Screen (default)
8X5
Window
S Wall 6 (Left-180)
--
1
40.0
0.50
0.26
Insect Screen (default)
8X5 2
Window
N Wall 7 (Right-0)
----
----
1
5.4
0.51
0.26
Insect Screen (default)
2.5X3 2
Window
N Wall 7 (Right-0)
---
----
1
6.3
0.50
0.26
Insect Screen (default)
10X11
Window
N Wall 8 (Right-0)
10.0
11.0
1
110.0
0.39
0.32
Insect Screen (default)
3X8
Window
E Wall 9 (Front-90)
----
-
1
24.0
0.51
0.26
Insect Screen (default)
8X8
Window
E Wall 9 (Front-90)
1
64.0
0.50
0.26
Insect Screen (default)
6X2.7
Window
E Wall 9 (Front-90)
1
16.2
0.50
0.26
Insect Screen (default)
8X5 3
Window
S Wall 7 (Left-180)
----
-
1
40.0
0.50
0.26
Insect Screen (default)
2.5X3 3
Window
W Wall 8 (Back-270)
-
1
7.5 1
0.50
0.26
Insect Screen (default)
3.5X4.5
Window
W Wall 8 (Back-270) --�T15.0
- -
1
6.3
0.50
0.26
Insect Screen (default)
15X11
Window
W Wall 8 (Back-270)
11.0
0.038
6.3
0.39
0.32
Insect Screen (default)
OPAQUE DOORS
01
02
03
04
Name
Side of Building
Area (ftft2)
U-factor
Door
E Wall 7
24.0
0.50
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 186 Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 9 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
OVERHANGS AND FINS
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
6X11
4
0.1
4
4
0
1 0
0
0
0
0
0
0
0
18X11
8
0.1
8
8
0
0
0
0
0
0
0
0
0
10.3X11
10
0.1
10
10
0
0
0
0
0
0
0
0
0
10.3X112
18
0.1
18
18
0
0
0
0
0
0
0
0
0
2.7X2.7
3
0.1
3
0
0
0
0
0
0
0
0
0
0
3X4
3
0.1
3
0
0
0
0
0
0
0
0
0
0
2.7X2.7 2
3
0.1
3
0
0
0
0
0
0
0
0
0
0
12X10
14
0.1
14
14
0
0
0
0
0
0
0
0
0
12.5X11
14
0.1
14
14
0
0
0
0
0
0
0
0
0
12.6X11
14
0.1
14
14
0
0
0
0
0
0
0
0
0
6.3X11
14
0.1
14
14
0
0
0
0
0
0
0
0
0
12.6X112
14
0.1
14
14
0
0
0
0
0
0
0
0
0
44X13
22
0.1
22
0
0
0
0
0
0
0
0
0
0
10.3X113
8
0.1
8
8
0
0
0
0
0
0
0
0
0
10.3X114
10
0.1
10
10
0
0
0
0
0
0
0
0
0
24X11
12
0.1
12
12
0
0
0
0
0
0
0
0
0
10X11
4
0.1
4
4
0
0
0
0
0
0
0
0
0
15X11
18
0.1
18
18
0
0
0
0
0
0
0
0
0
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration DatefFime: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B
Calculation Description: Title 24 Analysis
Calculation DatefTime: 11:06, Fri, May 03, 2019
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
CFI R-PRF-01
Page 10 of 16
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofMaster
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-14.3/2x6
R-38 Pitched Roof w/ R-1
attic)
Wood Framed Ceiling
2x6 @ 16 in. O.C.
R 38
0.026
Over Ceiling Joists: R-23.7 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W 21 2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
Inside Finish: Gypsum Board
Cavity/Frame: no insul. /2x4
R-0 Interior Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0 277
Other Side Finish: Gypsum Board
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofKitchen/Utility
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Inside Finish: Gypsum Board
• Cavity/Frame: R-13/2x4
R-13 Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O C.
R 13
0.092
Other Side Finish: Gypsum Board
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck. Wood Siding/sheathing/decking
Attic RoofOffice
Attic Roofs
Wood Framed Ceiling
in O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R- 13 0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedroom 2
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBar
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofLiving/Foyer
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
Registration Number: 219-P010033172B-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Registration Date/Time: 2019-05-03 11:13:38
Report Version - CF1 R-01162019-1149
HERS Provider: CaICERTS inc.
Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 11 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
- Roof Deck: Wood Siding/sheathing/decking
Attic RoofFlex
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity/Frame: R-13.0/2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofRec Room
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedroom 3/Hall
Attic Roofs
Wood Framed Ceiling
in. 0 C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBedroom 4
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
• Around Roof Joists: R-0.0 insul.
• Cavity / Frame: R-13.0 / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic RoofGuest
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 13
0.078
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab
Master
1398
125
None
0.8
No
Slab 2
Kitchen/Utility
1297
125
None
0.8
No
Slab 3
Office
833
73
None
0.8
No
Slab 4
Bedroom 2
712
71
None
0.8
No
Slab 5
Bar
343
14
None
0.8
No
Slab 6
Living/Foyer
1425
125
None
0.8
No
Slab 7
Flex
609
23
None
0.8
No
Slab 8
Rec Room
956
76
None
0.8
No
Slab 9
Bedroom 3/Hall
777
71
None
0.8
No
Slab 10
Bedroom 4
466
14
None
0.8
No
Slab 11
Guest
1631
184
None
0.8
No
Registration Number: 219-PO10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 12 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII)
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01 02
03
04
05
06
Name System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 DHW
Standard
DHW Heater 1 (2)
2
.0%
WATER HEATERS
01
02
03
04
05
06
07 08
09
10
11
12
Input Rating / Tank
Standby
Heater
Tank
Uniform Energy
Pilot / Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor I Efficiency
Efficiency (Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Small
2
0
0.95 EF
<= 200 kBtu/hr R-0/R-0
0
n/a
n/a
n/a
Instantaneous
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC Zone 31
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
HVAC Zone 12
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
HVAC Zone 23
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
HVAC Zone 44
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
HVAC Zone 55
Other Heating and Cooling
System
Heating Component 5
Cooling Component 5
HVAC Fan 5
Air Distribution System 5
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation DatelTime: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 13 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
HVAC - HEATING UNIT TYPES
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component 1
CntrlFurnace
1
80 AFUE
Heating Component 2
CntrlFurnace
1
80 AFUE
Heating Component 3
CntrlFurnace
1
80 AFUE
Heating Component 4
CntrlFurnace
1
80 AFUE
Heating Component 5
CntrlFurnace
1
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Efficiency
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
3-hers-cool
Cooling Component 4
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
4-hers-cool
Cooling Component 5
SplitAirCond
1
13
16
Not Zonal
Single Speed
Cooling Component
5-hers-cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-cool
Required
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
Cooling Component 5-hers-cool
Required
350
Required
Required
Required
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
CF1 R-PRF-01
Page 14 of 16
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribdl6x
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
1-hers-dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
2-hers-dist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
3-hers-dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
4-hers-dist
Air Distribution System 5
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Target
5-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-dist
Required
60
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 5-hers-dist
Required
6.0
Not Required
Not Required
Not Required
Not Required
Required
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type
Fan Power (WattsICFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
05
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.5
HVAC Fan 2-hers-fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.5
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.5
HVAC Fan 4-hers-fan
HVAC Fan 5
Single Speed PSC Furnace Fan
0.5
HVAC Fan 5-hers-fan
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
Calculation Description: Title 24 Analysis Input File Name: Madison Lot 18B-Radford-19.ribdl6x
CF1 R-PRF-01
Page 15 of 16
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan
Required
0.50
HVAC Fan 2-hers-fan
Required
0.50
HVAC Fan 3-hers-fan
Required
0.50
HVAC Fan 4-hers-fan
Required
0.50
HVAC Fan 5-hers-fan
Required
0.50
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
157
0.25
Default
0
Required
� CaICERTS, Inc.
Registration Number: 219-P010033172B-000-000-0000000-0000 Registration DateMme: 2019-05-03 11:13:38 HERS Provider: CaICERTS inc
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 Report Generated at: 2019-05-03 11:08:43
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Madison Lot 18B Calculation Date/Time: 11:06, Fri, May 03, 2019
Calculation Description: Title 24 Analysis
Input File Name: Madison Lot 18B-Radford-19.ribd16x
CF1 R-PRF-01
Page 16 of 16
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature
Tim Scott
-
Company:
Signature Date:
Scott Design and Title 24, Inc.
2019-05-03 11:13:38
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance
are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature
Tim Scott
G.yfi�CBi
Company:
Date Signed:
Scott Design and Title 24, Inc.
2019-05-03 11:13:38
Address:
License:
77085 Michigan Drive
NA
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 219-PO10033172B-000-000-0000000-0000 Registration Date/Time: 2019-05-03 11:13:38
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149
Easy to Verify
at CaICERTS.com
HERS Provider: CaICERTS inc.
Report Generated at: 2019-05-03 11:08:43