BRES2018-0156 Title 244
Opt rill
oil
x;
a
F
:.c
S FN.0 E
196,
A TRUSTED PARTNER IN
INNOVATION, QUALITY & SERVICE
ENERGY CALCULATION (T-24)
(A Custom Home)
Varnum Residence'
Lot 36, 56185 Village Drive
La Quinta, County of Riverside, CA
Gouvis Job No.: 64751
CITY OF LA QUINTA
Developer BUILDING & SAFETY DEPT.
Micheline Varnum
APPROVED
FOR CONSTRUCTION
Architect DATE%Wk/ v B y._
Pekarek Architects
aw f
CO CITY �0OF L.4 0UBNTA
949.752.1612 UEV ELOPrWENT
15 Studebaker
Irvine, CA
92618
www.gouvisgroup.com Palm Springs, CA Pleasanton, CA Ho Chi Minh City, Vietnam p� „
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 1318, Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Input File Name:'tmp23E3.tmp.xml
CF1 R-PRF-01
Page 1 of 13
GENERAL INFORMATION
01
Project Name
Varnum Residence
02
Calculation Description
Title 24 Analysis
03
Project Location
La Quinta
04
City,
Riverside
05
Standards Version
Compliance 2017
06
Zip Code
92253
07
Compliance Manager Version
BEMCmpMgr 2016.3.0 (1016 SP2)
08
Climate Zone
CZ15
09
Software Version
EnergyPro 7.2
10
Building Type
Single Family
11
Front Orientation (deg/Cardinal)
90
12
Project Scope
Newly Constructed
13
Number of Dwelling Units .
1
14
Total Cond. Floor Area (ft2)
5442
15
Number of Zones
4
16
Slab Area (ftZ)
5442
17
Number of Stories
1
18
Addition Cond. Floor Area(ft2)
Na
19
Natural Gas Available
Yes
20
Addition Slab Areaa., 2)'
n/a
21
Glazing Percentage (%)
29.1%
COMPLIANCE RESULTS
01
Building Complies witi4'Compute_1:'Performance`Q
02
i f � 4' A €�. Yt1 '! 1� --3.'isi[t'� 6P�;CRY' � -' 7ki. iH Y' yv
This building, incorporates°features�that require field testing and/or verification�by 1certifi64HERS rater indetthe supervision of a CEC-approved HERS provider.
,. .1:
03
vim+.•-- t..,f,•a A+ _.:�.�g.:
This building incorporates one•or,more SpeciaPFeatures shown below
riR:"__> r K%—; V{L..# C K
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDVfft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
1.71
3.80
-2.09
-M.2%
Space Cooling
78.92
70.83
8.09
10.3%-
IAQ Ventilation
0.84
0.84
0.00
0.0%
Water Heating
3.01
8.49
-5.48
-182.1 %
Photovoltaic Offset
----
0.00
0.00
—
Compliance Energy Total
84.48
83.96
0.52 •
0.6% . "
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE =RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018 Page 2 of 13
Calculation Description: Title 24 Analysis Input File Name: tmp23E3.tmp.xml
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building. Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency
EDR of Proposed Efficiency
EDR Value of Proposed PV + Battery
Final Proposed EDR
50.0
49.6
0.0
49.8
❑
Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreenA4.203.1.2.1) and QII verification prerequisite.
❑
Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑
Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone C215 (Palm Springs) (CALGreen A4.203.1.2.3) including on -site
photovoltaic (PV) renewable energy generation. sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes: 1 \<
- Excess PV Generation EDR Credit: Bypassing PV, size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES
., ,' IF ---r✓ k ` fs'"°"y �•,�,v. p gnygy t'a.E � R•+.� T S
The following are features that must be inst%alll4ddas condition'for meeting the�modeled,energytperformance forttbs computer analysis
• Cool roof g (,�" � - _ d
• Window overhangs and/or fins L . 0o u.
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as.a condition for meeting the modeled energy performance for -this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• High quality insulation installation (QII)
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit
Domestic Hot Water System Verifications:
• --None --
Registration Number: 218-Po10160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE -'RESIDENTIAL PERFORMANCE'COMPLIANCE METHOD`
Project Name: Varnum Residence Calculation'Date/Time: 13:18, Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Inputfile Name: tmp23E3.tmp.xml
CF1 R'-PRF-o1
Page 3 of 13
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07,
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventiiation
Cooling Systems
Number of Water
Heating Systems
Varnum Residence
5442
1
5
4
0
2
ZONE INFORMATION
.01
02
03
64
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Master Bedroom
Conditioned
FAU 421
1700
10
DHW Sys 1
DHW Sys 2
GREAT ROOM & KITCHEN
Conditioned
FAU 482
1780
10
DHW Sys 1
DHW Sys 2
BEDROOM 2&3
Conditioned
FAU 363
1200
10
DHW Sys 1
DHW Sys 2
BEDROOM 4 & CASITA
Conditioned
FAU 184
762
10
DHW Sys 1
DHW Sys 2
110%tc.
aM° I _ ; Y
s PROVIDER
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
CF1R-PRF-01
Page 4 of 13
Calculation Description: Title 24 Analysis
Input File Name: tmp23E3.tmp.xml
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door Area (ftZ)
Tilt (deg)
N Exterior Wall 2x6
Master Bedroom
R-21 Wall
90
Front
308
20
90
N Exterior Wall
Master Bedroom
R-13 Wall
90
Front
111.7
49.5
90
E Exterior Wall 2x6
Master Bedroom
R-21 Wall
90
Front
242
48
90
E Exterior Wall
Master Bedroom
R-13 Wall
90
Front
20.8
0
90
S Exterior Wall 2x6
Master Bedroom
R-21 Wall
270
Back
792
131.5
90
W Exterior Wall 2x6
Master Bedroom
R-21 Wall
0
Right
471.2
208
90
W Exterior Wall
Master Bedroom
R-13 Wall
0
Right
20.8
0
90
Interior Surface
Master Bed room» Garage_
R-11 Party Wall
n/a
n/a
335.8
0
n/a
Roof
Master Bedroom
R-38 Roof Attic
n/a
n/a
1700
n/a
n/a
N Exterior Wall 2x6 2
GREAT ROOM & KITCHEN
R-21 Wall
90
Front
413.3
155.5
90
E Exterior Wall 2x6 2 ,
- GREAT ROOM-& KITCHEN
R-21 Wall
180
Left
391.5
119
90
W Exterior Wall 2x6 2
GREAT ROOM & KITCHEN!
., R-21 Wall
0
Right
681.5
372.12
90
Interior Surface 2
� GREAT 1200M & r
KITCHEN» t'Garagefil
1�
-11 Pa-Walln/a
f~- 1��
(Fil
n1a
;,
285
0
n/a
Interior Surface 3
GREATROOME`& KITCHEN»Master
Bedroom% LJ
U N4. 'L� U U
� DR-1<Party Wall 0 [
J �� ff
,' %/*0 11
U U'0 N4
r,* n/: C
100
485.8
0
n/a
Roof 2
GREAT ROOM & KITCHEN
WR-38 Roof Attic
n/a -
... n/a -
1780
n/a
n/a
N Exterior Wall 2x6 3
BEDROOM 2&3
R-21 Wall
90
Front
659.2
134.5
90
E Exterior Wall 2x6 3
BEDROOM 2&3
R-21 Wall
180
Left
30
0
90
S Exterior Wall 2x6 2
BEDROOM 2&3
R-21 Wall
270
Back
325
96
90
W Exterior Wall 2x6 3
BEDROOM 2&3
R-21 Wall
0
Right
205
96
90
Interior Surface 4
BEDROOM 2&3»GREAT ROOM &
KITCHEN
R-11 Party Wall
n/a
n/a
205.4
0
n/a
Roof 3
BEDROOM 2&3
R-38 Roof Attic
n/a
n/a
1200
n/a
n/a
N Exterior Wall 2x6 4
BEDROOM 4 & CASITA
R-21 Wall
90
Front
191.3
23
90
E Exterior Wall 2x6 4
BEDROOM 4 & CASITA
R-21 Wall
180
Left
365
58
90
S Exterior Wall 2x6 3
BEDROOM 4 & CASITA
R-21 Wall
270
Back
255
0
90
W Exterior Wall 2x6 4
BEDROOM 4 & CASITA
R-21 Wall
0
Right
190
72
90
Interior Surface 5
BEDROOM 4 &
CASITA—BEDROOM 2&3
R-11 Party Wall
n/a
n/a
235.8
0
n/a
Roof 4
BEDROOM 4 & CASITA
R-38 Roof Attic
n/a
n/a
762
n/a
n/a
Registration Number: 218-Po10160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance . Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE -'RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Input File. Name: tmp23E3.tmp.xml
CF1 R-PRF-01
Page 5 of 13
N Exterior Wall 2
Garage_
R-0 Wall
90
Front
300
0
90
E Exterior Wall '2
Garage_
R-0 Wall
180
Left
408.3
0
90
S Exterior Wall
Garage_
R-6 Wall
270
Back
530
0
90
Roof 5
Garage_
R-0 Roof Attic
n/a
n/a
1195
n/a
n/a
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic Master Bedroom
Attic RoofMaster Bedroom
Ventilated
4
0.4
0.85
Yes
Yes
Attic GREAT ROOM &
KITCHEN
Attic RoofGREAT ROOM &
KITCHEN
Ventilated
4
0.4
0.85
Yes
Yes
Attic BEDROOM 2&3
Attic RoofBEDROOM 2&3
Ventilated
4
0.4
0.85
Yes
Yes
Attic -BEDROOM 4 &-CASITA
Attic RoofBEDROOM 4 &
CASITAsgaJ
Ventilated
4
0.4
0.85
Yes
Yes
Attic Garage_
Attic�Garage Roof Cons.
Ventilated
4
0.1
0.85
No
No
..:
i E.
alLOF�.RTS'a'o.
Inc-,;
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-66-04 13:20:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
CF1 R-PRF-01
Page 6 of 13
Calculation Description: Title 24 Analysis
Input File Name: tmp23E3.tmp.xml
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
ll-factor
SHGC
Exterior Shading
Window 22
Window
N Exterior Wall 2x6 (Front-90)
----
---
1
10.0
0.30
•0.17
Insect Screen (default)
Window 23
Window
N Exterior Wall 2x6 (Front-90)
-
--
1
10.0
0.30
0.17
Insect Screen (default)
Window 24
Window
N Exterior Wall (Front-90)
----
----
1
16.5
0.30
0.17
Insect Screen (default)
Window 25
Window
N Exterior Wall (Front-90)
----
----
1
16.5
0.36
0.17
Insect Screen (default)
Window 26
Window
N Exterior Wall (Front-90)
---
- -
1
16.5
0.30
0.17
Insect Screen (default)
Door 16
Window
E Exterior Wall 2x6 (Front-90)
--
---
1
48.0
0.30
0.17
Insect Screen (default)
Window 12
Window
S Exterior Wall 2x6 (Back-270)
----
----
1
10.0
0.30
0.17
Insect Screen (default)
Window 13
Window
S Exterior Wall 2x6 (Back-270)
---
----
1
16.5
0.30
0.17
Insect Screen (default)
Door 15
Window, (\,
S Exterior Wall 2x6 (Back-270)
----
---
1
72.0
0.30
0.17
Insect Screen (default)
Window 17
Windov j
S Exterior Wall 2x6 (Back-270)
----
----
1
16.5
0.30
0.17
Insect Screen (default)
Window 18
�'Wiiidow
S.Exterior."'Wall 2i6`(Back-270)
----
----
1
16.5
0.30
0.17
Insect Screen (default)
Window 14.
Winnow
.�'-�"W Eztenor Wall 2zd (R;ght 0)
/
--
_1
72.0
0.30
0.17
Insect Screen (default)
Door 19
Window,',,,
W'Exterior Wall 2x'd (Right-0) WM I
*q 6.01
*t4.0
J If2
48.0
0.30
0.17
Insect Screen (default)
Door 21
Window
W Ex a or 1Na`II-2z6 (Right=0) 0= I
U6.03 I
-W8.6'
W *1 V
�W48:0
0.30
0.17
Insect Screen (default)
Window 20
Window
W Exterior WFall2x6(Righ -0) P
R5.0�
V8.01
D 1F
R40.0
0.30
0.17
Insect Screen (default)
Window 8
Window
N Exterior Wall 2x6 2 (Front-90)
--
----
1
16.5
0.30
0.17
Insect Screen (default)
Door 28
Window
N Exterior Wall 2x6 2 (Front-90)
11.0
12.0
1
132.0
0.30
0.17
Insect Screen (default)
Window 11
Window
N Exterior Wall 2x6 2 (Front790)
----
----
1
7.0
0.30
0.17
Insect Screen (default)
Window 7
Window
E Exterior Wall 2x6 2 (Left-180)
--
--
1
88.0
0.30
0.17
Insect Screen (default)
Door 9
Window
E Exterior Wall 2x6 2 (Left-180)
----
--
1
24.0
0.30
0.17
Insect Screen (default)
Window 10
Window
E Exterior Wall 2x6 2 (Left-180)
----
----
1
7.0
0.30
0.17
Insect Screen (default)
Window 27
Window
W Exterior Wall 2x6 2 (Right-0)
- -
----
1
120.0
0.30
0.17
Insect Screen (default)
Door 29
Window
W Exterior Wall 2x6 2 (Right-0)
22.0
12.0
0.955
252.1
0.30
0.17
Insect Screen (default)
Window 37
Window
N Exterior Wall 2x6 3 (Front-90)
--
--
1
11.0
0.30
0.17
Insect Screen (default)
Window 36
Window
N Exterior Wall 2x6 3 (Front-90)
----
---
1
11.0
0.30
0.17
Insect Screen (default)
Window 35
Window
N Exterior Wall 2x6 3 (Front-90)
----
-
1
6.0
0.30
0.17
Insect Screen (default)
Door
Window
N Exterior Wall 2x6 3 (Front-90)
-
-
1
40.0
0.30
0.17
Insect Screen (default)
Window 34
Window
N Exterior Wall 2x6 3 (Front-90)
-
---
1
6.0
0.30
0.17
Insect Screen (default)
Window 33
Window
N Exterior Wall 2x6 3 (Front-90)
---
----
1
27.5
0.30
0.17T
Insect Screen (default)
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE'OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
CF1 R-PRF-01
Page 7 of 13
Calculation Description: Title 24 Analysis
Input File Name: tmp23E3.tmp.xml
Window 32
Window
N Exterior Wall 2x6 3 (Front-90)
----
----
1
16.5
0.30
0.17
Insect Screen (default)
Window 31
Window
N Exterior Wall 2x6 3 (Front-90)
----
----
1
16.5
0.30
0.17
Insect Screen (default)
Door 5
Window
S Exterior Wall 2x6 2 (Back-270)
----
---
1
48.0
0.30
0.17
Insect Screen (default)
Door 6
Window
S Exterior Wall 2x6 2 (Back-270)
-
---
1
48.0
0.30
0.1.7
Insect Screen (default)
Window 30
Window
W Exterior Wall 2x6 3 (Right-0)
12.0
8.0
1
96.0
0.30
0.17
Insect Screen (default)
Window 38
Window
N Exterior Wall 2x6 4 (Front-90)
--
----
1
6.0
0.30
0.17
Insect Screen (default)
Window 39
Window
N Exterior Wall 2x6 4 (Front-90)
---
- -
1
11.0
0.30
0.17
Insect Screen (default)
Window 40
Window
N Exterior Wall 2x6 4 (Front-90)
-
----
1
6.0
0.30
0.17
Insect Screen (default)
Window 41
Window
E Exterior Wall 2x6 4 (Left-180)
-
----
1
25.0
0.30
0.17
Insect Screen (default)
Window 1
Window
E Exterior Wall 2x6 4 (Left-180)
----
---
1
11.0
0.30
0.17
Insect Screen (default)
Window 2
Window
E Exterior Wall 2x6 4 (Left-180)
----
----
1
11.0
0.30
0.17
Insect Screen (default)
Window 3
Window A
E Exterior Wall 2x6 4 (Left-180)
----
----
1
11.0
0.30
0.17
Insect Screen (default)
Window 4
0ndo4A
W Exterior Wall 2x6 4 (Right-0)
-
---
1
72.0
1 0.30
0.17
Insect Screen (default)
OVERHANGS AND FINS+.«.
01
02
03
'
fi�^^"04
05 _
06
07 _
08
09
10
11
12
13
14
eV�hang, 0 r--
L'#eq:�,
. ,,m
Right Fin
Window
Depth
qAO
Dist Up `�Ex`tIL
ft
Left
eght
Ex!tent�
Flap•H
DDepth
Top Upist
L*
IbBot Up
Depth
Top Up
Dist R
Bot Up
Door 19
10
'4,^1
K1.5 E.
R1.5S
Po R
Co N
I Q
E. 0R
0
0
0
0
0
Door 21
10
1
1.5
1.5
0
0
0
0
0
0
0
0
0
Window 20
10
11
1.5
1.5
0
0
0
0
0
0
0
0
0
Door 28
27
1
1
1
0
0
0
0
0
0
0
0
0
Door 29
16
1
2
2
0
0
0
0
0
0
0
0
0
Window 30
18.5
1
1
1
0
0
0
0
0
0
0
0
0
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name:.Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
CFI R-PRF-01
Page 8 of 13
Calculation Description: Title 24 Analysis
Input File Name: tmp23E3.tmp.xml
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R-value
U-factor
Assembly Layers
• Inside Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4
R-0 Wall .
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
none
0.361
Exterior Finish: 3 Coat Stucco
Ceilings (below
2x4 @ 24 in. O.C. with Raised Heel
Inside Finish: Gypsum Board
R-0 Roof Attic
attic)
Wood Framed Ceiling
Truss Height 4 in
none
0.481
Cavity/Frame: no insul. /2x4
• Cavity / Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: • Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
Attic RoofMaster Bedroom
Attic Roofs rt
Wood Framed Ceiling
in. O.C.
none
0.400
Roofing: 10 PSF (RoofTile)
Inside Finish: Gypsum Board
a
• Cavdy / Frame: R-21 / 2x6
R-21 Wall
ExteriocWalls
oodFr�a`eWall�•�
fq 2x6 @ 16. in. O:C.
R 21
0.069
Exterior Finish: 3 Coat Stucco
fO.Q.
Inside Finish: Gypsum Board
Cavity / Frame: R-13 / 2x4
R-13 Wall
Exterior Walls
Wood Framed Wall
2x4,@x16 t
R 13
Exterior Finish: 3 Coat Stucco
H E
�7
R S P R®
V-1 D
_ R
Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-11 / 2x4
R-11 Party.Wall
Interior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 11
0.099
Other Side Finish: Gypsum Board
• Cavity / Frame: no insul. / 2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
Attic RoofGREAT ROOM &
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
KITCHEN
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.400
Roofing: 10 PSF (Rooffile)
• Cavity / Frame: no insul. / 2x4 Top Chrd
• Roof Deck: Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
Attic RoofBEDROOM 2&3
Attic Roofs
Wood Framed Ceiling
in. O.C..
none
0.400
Roofing: 10.PSF (Rogme)
• Cavity/Frame: no insul. /2x4 Top Chrd-
Roof Deck: Wood Siding/sheathing/decking
Attic RoofBEDROOM 4 &
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
CASITA
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.400
Roofing: 10 PSF (RoofTile)
Registration Number: P18-P010160138A-000-000-0000000-0000 Registration Daterrime: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCEMETHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
CF1 R-PRF-61
Page 9 of 13
Calculation Description: Title 24 Analysis
Input File Name: tmp23E3.tmp.xml
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R-value & Depth
Carpeted Fraction
Heated
Slab -on -Grade
Master Bedroom
1700
0.1
None
0.8
No
Slab -on -Grade 2
GREAT ROOM & KITCHEN
1780
0.1
None
0.8
No
Slab -on -Grade 3
BEDROOM 2&3
1200
0.1
None
0.8
No
Slab -on -Grade 4
BEDROOM 4 & CASITA
762
0.1
None
0.8
No
Slab -on -Grade 5
Garage_
1195
0.1
None
0
No
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality Insulation Installation (QII) i
Quality Installation of Spray Foam Insulation
Building Envelope Air Leakage
CFM50
Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02 ;
03
0.4
05
06
Name
System Type
Distribution Type
WaterlHeat_er
Number of Heaters
Solar Fraction (%)
DHW Sys 1
�DHW� f
Stand d
'DHW Heat" 1 (i1).
1
.0%
DHW Sys 2
�D,HVU `
>K Stand d
DHW Heate 2 (1") ..
1
.0%
WATER HEATERS ' ' '" ' "r " q v `i v a n✓ a s
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating /
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model I
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency.
Efficiency
(Int/Ext)
Eff
Flow Rate
Other
Condition
DHW Heater 1
Gas
Large Storage
1
60
0.95 frac
120,000 Btu/hr
R-0/R-0
0.05
n/a
n/a
n/a
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
Input Rating I
Tank
Standby
Heater
Tank
Uniform Energy
Pilot /
Insulation
Loss /
First Hour
NEEA Heat Pump
Tank Location
Element
Number
Volume
Factor / Energy
Thermal
R-value
Recovery
Rating /
Brand / Model /
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor / Efficiency
Efficiency
(InVExt)
Eff
Flow Rate
Other
Condition
DHW Heater 2
Gas
Consumer
1
38
0.55 UEF
40,000 Btu/hr
R-0/R-0
n/a
38 gal
n/a
n/a
Storage (UEF)
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE RESIDENTIAL PERFORMANCE COMPLIANCE'METHOD
`
Project Name: Varnum Residence Calculation Date/Time: 13:18,,Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Input File Name: tmp23E3.tmp.xml
CF1 R-PRF-01
Page 10 of 13
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System'Type
Heating UnitName
Cooling Unit Name
Fan Name
Distribution Name
FAU 421
Other Heating. and Cooling
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
System
FAU 482
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
FAU 363
Other Heating and Cooling
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
System
FAU 184
Other Heating and Cooling
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
System
HVAC - HEATING UNIT TYPES R
01
02
03
04
Name
System Type
Number of Units
Efficiency
Heating Component,.;1 .Jl
,. CntrlFurnace
1
92.1 AFUE
Heating Component"2�
,,,�,.r^CntrlFurnace
1
92.1 AFUE
Heating Component 3�''`CntrlFu
nr acei
► �1
92:1 AFUE
Heating Component 4 Tw
CntrlFu nr ac . _ `. _ .
11
92.1 AFUE
HVAC - COOLING UNIT TYPES
01
02
— .03 ...�
_ 04w
—. 05
_ , 06
07
08
Efficiency ,
Name
System Type
Number of Units
EER SEER
Zonally Controlled
Compressor Type
HERS Verification
Cooling Component 1
SplitAirCond
1
13.5
15.5
Not Zonal
Single Speed
-
Cooling Component
1-hers-cool
Cooling Component 2
SplitAirCond
1
12.5
16
Not Zonal
Single Speed
Cooling Component
2-hers-cool
Cooling Component 3
SplitAirCond
1
13.5
15.5
Not Zonal
Single Speed
•
Cooling Component
37hers-coot
Cooling Component
Cooling Component 4
SplitAirCond
1
13
16
Not Zonal
Single Speed
4-hers-cool
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016'Residential Compliance Report Version - CF1R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE - RESIDENTIAL'PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Input File Name: tmp23E3.tmp.xml
'CF1 R-PRF-01
Page 11 of 13
HVAC COOLING - HERS VERIFICATION
01
02
03
04:
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1-hers-cool
Required
350
Required
Required
Required
Cooling Component 2-hers-coo1
Required.
350
Required
Required
Required
Cooling Component 3-hers-cool
Required
350
Required
Required
Required
Cooling Component 4-hers-cool
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R-value.
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
Target
6
Attic
None
Air Distribution System
1-hers-dist
Air Distribution System 2
`
DuctsAttic-.
Specified Lower Leakage
Target.
6
Attic
None
Air Distribution System
2-hers dirt
Air Distribution System 3
DuctsAttic;,
Specified Lowe4 Leakage.
,
6
Attic
None
Air Distribution System
3-hers dish
per, .... 9.
> .�
Air Distribution System 4uctsAttic_
AD
Speafied Lower Leakage
r-
6.
-
Attic
None
Air Distribution System
-90 Tar eta
g
1�
4-hers-dist
HVAC DISTRIBUTION - HERS VERIFICATION
ifs
01
02
03
04
05
06
07
68
Name
Duct Leakage
Verification
Duct.Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 2-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 3-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Air Distribution System 4-hers-dist
Required
5.0
Not Required
Not Required
Not Required
Not Required
Required
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE- RESIDENTIAL PERFORMANCE COMPLIANCE -METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Input•File.Name: tmp23E3.tmp.xml
CF1 R-PRF-01
Page 12 of 13
HVAC-FAN SYSTEMS
01
02
03
04
Name
Type `
Fan Power.(Watts/CFM)�
HERS Verification
HVAC Fan 1
Single,Speed PSC Furnace Fan
0.48
HVAC Fan 1-hers-fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.48
HVAC Fan 2-hers-fan
HVAC Fan 3
Single'Speed PSC Furnace Fan
0.48
HVAC Fan 3-hers-fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.48
HVAC Fan 4-hers-fan _
HVAC FAN SYSTEMS- HERS VERIFICATION '
01
02
03
Name.
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1-hers-fan,
Required
0.48
HVAC Fan 2-hers-fan
Required
0.48
HVAC Fan 3 hers fan •¢
Required ;
0.48
HVAC Fan 4he fan'"" ,J1
•, - ° .
Required-
0.48
IAQ (Indoor Air Quality) FANS' ,
01
fad€ .r02 -
_1ii 03 -
04 .'
05
O6
-
Dwelling Unit
Y X
IA`CFMJ i..a .
OU U :U . U U 44
0 r<AAQ Watts�CF 4Z f-I 1
I W U U'
,_/ .1IAQ Fan Ty,Pe.0
aDefault
IAQ-Recove ry
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
99
0.25
0
Required
Registration Number: 218-P010160138A-000-000-0000000-0000 Registration Date/Time: 2018-06-12 13:17:55 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2 Report Generated at: 2018-06-04 13:20:10
CERTIFICATE OF COMPLIANCE -RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Varnum Residence Calculation Date/Time: 13:18, Mon, Jun 04, 2018
Calculation Description: Title 24 Analysis Input File Name: tmp23E3.tmp.xml
CF1 R-PRF-01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Guehee Park
Company:
Signature Date:
Gouvis Engineering Consulting Group
2018-06-04 13:59:45
Address:
CEA/HERS Certification Identification (If applicable):
15 Studebaker
N/A
City/State/Zip:
Phone:
Irvine, CA 92618
949-752-1612
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, underthe laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.~ {
3. The building design featuresm of system -design features identified ,owthis'Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and,specificationssubmitted the enforccement,agency for approva- ll h thi building permit application.
Responsible Designer Name: yr;r"�
d r`
hespons,ible.,Designer Signature—i
Mark Pekarek / f'��k
..11 as to
Company:
Date Signed:
Pekarek Architects, Inc.
2018-06-12 13:17:55
Address:
License:
31411 Camino Capistrano, Suite 300
C-29159
City/State/Zip:
Phone:
San Juan Capistrano, CA 92675
949-487-2320
Digitallyy signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 218-Po10160138A-000-000-0000000-0000 Registration Daterrime: 2018-06-12 13:17:55
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-04302018-1016 SP2
HERS Provider: CaICERTS inc.
Report Generated at: 2018-06-04 13:20:10