Loading...
BPOL2022-023978-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/1/2022 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: POOL CONSTRUCTION (WEB)/PRIVATE BPOL2022-0239 61545 TORO CANYON WAY 764540047 RICHARDS / POOL AND SPA AT REAR YARD. $20,000.00 Owner: Judy Massett-Richards Applicant: REMBRANDT POOLS AND SPAS INC 41945 Boardwalk, Ste. I Palm Desert, CA 92211 Contractor: Jorge Silva PO BOX 6411 LA QUINTA, CA 92248 (760)771-2121 LIc. No.: 800680 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: 800680 Date: Contractor: OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (___) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (___) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (___) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:_______________________________________________ Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Date: 9/1/2022 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: BPOL2022-0239 61545 TORO CANYON WAY 764540047 RICHARDS / POOL AND SPA AT REAR YARD. $20,000.00 Owner: Judy Massett-Richards Applicant: REMBRANDT POOLS AND SPAS INC 41945 Boardwalk, Ste. I Palm Desert, CA 92211 Contractor: Jorge Silva PO BOX 6411 LA QUINTA, CA 92248 (760)771-2121 LIc. No.: 800680 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Detail: RICHARDS / POOL AND SPA AT REAR YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $83.50 Total Paid for BLDG CITY STAFF - PER HOUR: $83.50 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT SWIMMING POOL/SPA/WATER FEATURE 101-0000-42404 0 $208.41 DESCRIPTION ACCOUNT QTY AMOUNT SWIMMING POOL/SPA/WATER FEATURE PC 101-0000-42600 0 $113.38 Total Paid for POOL / SPA 2021: $321.79 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 Total Paid for RECORDS MANAGEMENT FEE: $11.00 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 TOTALS:$422.29 54'14' 2" 13' 6"35'15' 6"16'3'3'8'12' 3"20' 3"5' 3 "2' 3"Water (Suction)Water (Suction)Water (Return)Bonding Wire Bonding Wire GasElectElect ElectScale: 1/8" = 1 ft X_________________________ Submitted by Builder Jorge Silva CA LIC. #800680 Specifications Government code section 4216.2.(a)(1) Except in an emergency, any person planning to conduct any excavation shall contact the appropriate Regional Notification Center, at least two working days, but not more than 14 calendar days, prior commencing excavation, if the excavation will be conducted in an area that is known, or reasonably should be known, to contain subsurface installations other than the underground facilities owned or operated by the excavator and if practical, the excavator shall delineate with white paint or other suitable marking the area to be excavated. Safety REMBRANDT POOLSNo overhead Electrical Wires Yes or No Safety Self Latching/Closing Gates with Release no lower than 54". Safety Alarms on any Doors with Direct Access to Pool. Pool Eye Splase Alarms Pool and Spa. Techko Safe Alarms on Doors. Notes Equipment is Seismically Anchored to Concrete Pad. 3' Set Back with minimum clearance for Disconnect. Masset Richards ResidenceOwner:Judy Masset Richards Address:61545 Toro Canyon Way City:La Quinta Phone:206-550-7531 State:CA Zip:92253 Pool Size 16' W x 35' L Freeform Perimeter 94 Lf 432 Sq Ft Depth 3'6" to 6' Elevation Zero Level Notes Spa Size 8' Round Perimeter 25 Lf 50 Sq Ft Depth 3'6" Elevation Raised 18" Notes Raised Bond Beam No Size W x L x H Features (X) W Descents Veneer Stone Notes Tile and Stone W/L Pool and Spa - Tile Porcelain - Yes Glass - No Trim - No Excavation / Steel Access Gate Type Mini Cat Elevation Zero Deep End Ramp No Bench Yes Tanning Shelf No Demoiltion No Concrete No Sod Yes Pool/Spa removal No Trees TBD Landscape TBD Plumbing - Pentair Equipment Filter - 420 Cartridge Pumps - 3HP VS Heater - 400 BTU Sub-Panel Easy Touch 4 Controls Chlorinator - Salt system Skimmer Type - Dual Port Auto Fill MP Products Lights Pool: 2 - Spa: 1 PVC Pipe 2,1/2" Suction and Returns Anti Entrapment Yes Water Features; Yes Gas Lines are 1 1/2" Polyethylene Decking 370 Sq Ft w/Pool & Spa Type Concrete / Travertine Coping 117 Sq Ft Pool+Spa Type Same Grey Concrete Cantilever Yes Double Cantilever Spa only Drains (1) Pool and (1) Spa Step Pads Yes Equipotential Bonding - Yes Wire Mesh/Rebar Yes Bands No Tile Base No Sleeves Expansion Joints - Yes Sand and Visqueen - No Plaster Mini Pebble - Yes Anti Vortex Drain\Eye Ball Fittings Fencing Existing Type Existing Block Wall Height 6' Gate - Yes Gate Reversal - Yes Remove and Re-hang - Yes Miscellaneous Misting System - No Pergola No Lattice - NA Lighting - NA Notes Fire Pits and BBQ's use a Manual Light Gas Valve , ANSI Z 21.5 unless otherwise specified. Owner Responsibilities; Determine approximate Elevation and layout Day of Excavation. Wet down Gunite Shell twice daily for at least seven Days after Installation. Take notice that these drawings are the sole property of Rembrandt Pools and are not to be used by others with out written Permission or Prohibited by Law. Notice that location of Pool and Equipment are subject to Local Building Codes. See that Fences and Gates meet Local Codes for Pool Enclosure. Fill Pool immediately as directed - Do not use Rubber Hose. Safety Features: Anti-Entrapment Cover installation meeting current standards of the American Society for testing and materials or the American Society of Mechanical Engineers. Front of House Electrical: Equipotential Bonding Requirments shall be installed to eliminate voltage gradients in the Pool Area as per CEC ART 680.26 2019 California Residential 2019 California Building 2019 California Mechanical 2019 California Plumbing 2019 California Electrical 2019 California Energy 2019 California Energy Code Code (Based on 2018 IRC) Code (based on 2018 IBC) Code (based on 2018 UMC) Code (Based on 2018 UPC) Code (based on 2018 NEC) Green code Planter Planter Planter Pool Set Back High Density Polyethlene Gas Lines 1 & 1/2" to 2"Stub Out to Equipment at Location New Concrete 3'W New Concrete New Concrete Side Yard Set Back Identifying & Demonstrating Equipotential Bonding per New Concrete New Concrete 5'H Self Closing Latching Gate with Techko Alarm, no Spacing more than 4" including from Ground Gas Meter Electric Meter Air Conditioning Property Line 6' H Block Wall, Left Main Electric Panel, add a 50 Amp Breaker with #6 Wire in 3/4" PVC Conduit Bonding Wire Planter Planter Planter Pool Set Back Pool Dimensions Spa Dimension Pool Set Back 4X Steps 12"D Bench Existing Concrete 3'6" WD 6' WD Property Line, Rear Property Line, Rear Anti-Entrapment Covers meeting current standards of the American Society of Testing & Materials (ASTM) or American Society of Mechanical Engineers. Identifying the minimum 3' separation between all Drains and be hydraulically balanced between Pool & Spa. 5' MIN. 06/29/2022J.ANAYA BPOL2022-0239 RICHARDS / POOL AND SPA AT REAR YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE.