BPOL2022-023978-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/1/2022
Permit Type/Subtype:
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
POOL CONSTRUCTION (WEB)/PRIVATE
BPOL2022-0239
61545 TORO CANYON WAY
764540047
RICHARDS / POOL AND SPA AT REAR YARD.
$20,000.00
Owner:
Judy Massett-Richards
Applicant:
REMBRANDT POOLS AND SPAS INC
41945 Boardwalk, Ste. I
Palm Desert, CA 92211
Contractor:
Jorge Silva
PO BOX 6411
LA QUINTA, CA 92248
(760)771-2121
LIc. No.: 800680
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - -
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 {commencing with Section 7000} of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: License No.: 800680
Date: Contractor:
OWNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(___) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner-builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(___) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(___) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:_______________________________________________
Lender's Address:
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: Policy Number:
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
Date: 9/1/2022
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
BPOL2022-0239
61545 TORO CANYON WAY
764540047
RICHARDS / POOL AND SPA AT REAR YARD.
$20,000.00
Owner:
Judy Massett-Richards
Applicant:
REMBRANDT POOLS AND SPAS INC
41945 Boardwalk, Ste. I
Palm Desert, CA 92211
Contractor:
Jorge Silva
PO BOX 6411
LA QUINTA, CA 92248
(760)771-2121
LIc. No.: 800680
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - -Detail: RICHARDS / POOL AND SPA AT REAR YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE-PLASTER
INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN
AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT
HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $83.50
Total Paid for BLDG CITY STAFF - PER HOUR: $83.50
DESCRIPTION ACCOUNT QTY AMOUNT
BSAS SB1473 FEE 101-0000-20306 0 $1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION ACCOUNT QTY AMOUNT
SWIMMING POOL/SPA/WATER FEATURE 101-0000-42404 0 $208.41
DESCRIPTION ACCOUNT QTY AMOUNT
SWIMMING POOL/SPA/WATER FEATURE PC 101-0000-42600 0 $113.38
Total Paid for POOL / SPA 2021: $321.79
DESCRIPTION ACCOUNT QTY AMOUNT
RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00
Total Paid for RECORDS MANAGEMENT FEE: $11.00
DESCRIPTION ACCOUNT QTY AMOUNT
TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
TOTALS:$422.29
54'14' 2"
13' 6"35'15' 6"16'3'3'8'12' 3"20' 3"5' 3
"2' 3"Water (Suction)Water (Suction)Water (Return)Bonding Wire
Bonding Wire
GasElectElect
ElectScale: 1/8" = 1 ft
X_________________________
Submitted by Builder
Jorge Silva CA LIC. #800680
Specifications
Government code section 4216.2.(a)(1) Except in an emergency, any
person planning to conduct any excavation shall contact the
appropriate Regional Notification Center, at least two working days,
but not more than 14 calendar days, prior commencing excavation, if
the excavation will be conducted in an area that is known, or
reasonably should be known, to contain subsurface installations
other than the underground facilities owned or operated by the
excavator and if practical, the excavator shall delineate with white
paint or other suitable marking the area to be excavated.
Safety REMBRANDT POOLSNo overhead Electrical Wires Yes or No
Safety
Self Latching/Closing Gates with Release no lower than
54".
Safety Alarms on any Doors with Direct Access to Pool.
Pool Eye Splase Alarms Pool and Spa.
Techko Safe Alarms on Doors.
Notes
Equipment is Seismically Anchored to Concrete
Pad.
3' Set Back with minimum clearance for
Disconnect. Masset Richards ResidenceOwner:Judy Masset Richards
Address:61545 Toro Canyon Way
City:La Quinta
Phone:206-550-7531
State:CA
Zip:92253
Pool Size 16' W x 35' L
Freeform
Perimeter 94 Lf 432 Sq Ft
Depth 3'6" to 6'
Elevation Zero Level
Notes
Spa Size 8' Round
Perimeter 25 Lf 50 Sq Ft
Depth 3'6"
Elevation Raised 18"
Notes
Raised Bond Beam No
Size W x L x H
Features (X) W Descents
Veneer Stone
Notes
Tile and Stone
W/L Pool and Spa - Tile
Porcelain - Yes
Glass - No
Trim - No
Excavation / Steel
Access Gate Type Mini Cat
Elevation Zero
Deep End Ramp No
Bench Yes
Tanning Shelf No
Demoiltion No
Concrete No
Sod Yes
Pool/Spa removal No
Trees TBD
Landscape TBD
Plumbing - Pentair Equipment
Filter - 420 Cartridge
Pumps - 3HP VS
Heater - 400 BTU
Sub-Panel Easy Touch 4
Controls
Chlorinator - Salt system
Skimmer Type - Dual Port
Auto Fill MP Products
Lights Pool: 2 - Spa: 1
PVC Pipe 2,1/2" Suction and
Returns
Anti Entrapment Yes
Water Features; Yes
Gas Lines are 1 1/2"
Polyethylene
Decking 370 Sq Ft w/Pool &
Spa
Type Concrete / Travertine
Coping 117 Sq Ft Pool+Spa
Type Same Grey Concrete
Cantilever Yes
Double Cantilever Spa only
Drains (1) Pool and (1) Spa
Step Pads Yes
Equipotential Bonding - Yes
Wire Mesh/Rebar Yes
Bands No
Tile Base No
Sleeves
Expansion Joints - Yes
Sand and Visqueen - No
Plaster
Mini Pebble - Yes
Anti Vortex Drain\Eye Ball
Fittings
Fencing Existing
Type Existing Block Wall
Height 6'
Gate - Yes
Gate Reversal - Yes
Remove and Re-hang - Yes
Miscellaneous
Misting System - No
Pergola No
Lattice - NA
Lighting - NA
Notes
Fire Pits and BBQ's use
a Manual Light Gas Valve ,
ANSI Z 21.5 unless otherwise
specified.
Owner Responsibilities;
Determine approximate
Elevation and layout Day of
Excavation.
Wet down Gunite Shell twice
daily for at least seven Days
after Installation.
Take notice that these
drawings are the sole
property of Rembrandt Pools
and are not to be used by
others with out written
Permission or Prohibited by
Law.
Notice that location of Pool
and Equipment are subject to
Local Building Codes.
See that Fences and Gates
meet Local Codes for Pool
Enclosure.
Fill Pool immediately as
directed - Do not use Rubber
Hose.
Safety Features:
Anti-Entrapment Cover
installation meeting current
standards of the American
Society for testing and
materials or the American
Society of Mechanical
Engineers.
Front of House
Electrical:
Equipotential Bonding
Requirments shall be installed
to eliminate voltage gradients
in the Pool Area as per CEC
ART 680.26
2019 California Residential
2019 California Building
2019 California Mechanical
2019 California Plumbing
2019 California Electrical
2019 California Energy
2019 California Energy Code
Code (Based on 2018 IRC)
Code (based on 2018 IBC)
Code (based on 2018 UMC)
Code (Based on 2018 UPC)
Code (based on 2018 NEC)
Green code
Planter
Planter
Planter
Pool Set Back
High Density Polyethlene Gas Lines 1
& 1/2" to 2"Stub Out to Equipment
at Location
New Concrete
3'W New Concrete
New Concrete
Side Yard Set Back
Identifying &
Demonstrating
Equipotential
Bonding per
New Concrete
New Concrete
5'H Self Closing Latching
Gate with Techko Alarm, no
Spacing more than 4"
including from Ground
Gas Meter
Electric Meter
Air Conditioning
Property Line 6' H Block Wall, Left
Main Electric Panel, add a 50
Amp Breaker with #6 Wire in
3/4" PVC Conduit
Bonding Wire
Planter
Planter
Planter
Pool Set Back
Pool Dimensions
Spa Dimension
Pool Set Back
4X Steps
12"D Bench
Existing Concrete
3'6" WD
6' WD
Property Line, Rear
Property Line, Rear
Anti-Entrapment Covers meeting current
standards of the American Society of
Testing & Materials (ASTM) or American
Society of Mechanical Engineers.
Identifying the minimum 3' separation
between all Drains and be hydraulically
balanced between Pool & Spa.
5' MIN.
06/29/2022J.ANAYA
BPOL2022-0239
RICHARDS / POOL AND SPA AT REAR YARD. TWO
DROWNING SAFETY FEATURES AND BARRIERS REQUIRED
TO BE INSTALLED AT PRE-PLASTER INSPECTION. PLEASE
PROVIDE WET STAMPED POOL ENGINEERING SHEET ON
SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT
MUST BE LOCATED IN AN APPROVED LOCATION EITHER
WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM
THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA BUILDING
CODE.