Loading...
BRES2021-0198Permit Details City of La Quinta Description: CANADY / 160SF GARAGE CONVERSION TO GUEST BEDROOM + REMODEL Type: BUILDING RESIDENTIAL Subtype: ADDITION Status: FINALED (WEB) Applied: 4/14/2021 ECON Approved: 6/28/2021 JFU Issued: 7/7/2021 ONLINE Finaled: 8/22/2022 JAN Expired: Parcel No: 646280001 Site Address: 49641 AVILA DR LA QUINTA,CA 92253 Subdivision: TR 8792-1 & INT IN COMMON AREA Block: Lot: 13 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $75,000.00 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: CANADY / 160SF GARAGE CONVERSION TO GUEST BEDROOM, RECONFIGURE VARIOUS WALLS, CREATE (3) NEW BATHROOMS, VARIOUS NEW DOORS AND WINDOWS, NEW ELECTRICAL & PLUMBING FIXTURES AT RESIDENCE AND EXISTING GAZEBO [ENGINEERED]. THIS PERMIT DOES NOT INCLUDE ALTERATION OF THE FIREPLACES NOR REPLACEMENT OF THE ELECTRICAL SERVICE PANEL, WATER HEATER OR HVAC SYSTEM. 2019 CALIFORNIA BUILDING CODES. Process Summary 411 \ 11141 /75 i Applied to Approved Approved to Issued Issued to Finaled ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL DUANE CLAYTON 9/3/2021 9/3/2021 - SENT CORRECTION LIST FOR FRAMIMG INSPECTION; AS WELL AS, SITE CORRECTIONS FOR UNPERMITTED WALL WORK AND DEBRIS IN RAIN GUTTERS. E-MAIL JAKE FUSON 5/12/2021 5/12/2021 NOTIFIED APPLICANT OF 1ST REVIEW, SENT CORRECTION LIST VIA EMAIL. E-MAIL JAKE FUSON 6/28/2021 6/28/2021 NOTIFIED OWNER AND GABRIEL LUJAN THAT PLANS ARE APPROVED AND PERMIT IS READY TO ISSUE PENDING RESOLUTION OF CONDITIONS FOR ISSUANCE. PLAN CHECK/PERMIT EXTENSION JACK LIMA 8/17/2022 8/17/2022 REINSPECTION FEE TO BE PAID BY THE APPLICANT AND PERMIT HAS BEEN EXTENDED UNTIL 9/1/2022 FOR SCHEDULING OF FINAL INSPECTION. RESUBMITTAL JAKE FUSON 6/7/2021 6/7/2021 2ND SUBMITTAL RECEIVED VIA ETRAKIT. CONDITIONS Printed: Monday, April 24, 2023 12:34:56 PM 1 of 10 CRWSYSTEMS Permit Details City of La Quinta CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST JAKE FUSON 5/12/2021 6/29/2021 COMPLETE SCHOOL FEE RECEIPT/EXEMPTION FORM REQUIRED PRIOR TO PERMIT ISSUANCE. SCHOOL FEE CERTIFICATE OF COMPLIANCE RECEIVED. CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT GABRIEL LUJAN CONTRACTOR VINCERE INDUSTRIES INC 30670 HILL DRIVE THOUSAND PALMS CA 92276 (760)904-4120 VINCEREINDUSTRIES@ GMAIL.COM OWNER CANADY FAMILY TRUST 49641 AVILA DR LA QUINTA CA 92253 ( DESCRIPTION ACCOUNT QTY FINANCIAL INFORMATION PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY AMOUNT PAID RE -INSPECTION FEE 101-0000-42400 0 $83.37 $83.37 8/17/22 WEB12793 708966348 CREDIT 968718 ECON Total Paid for ADMINISTRATIVE: $83.37 $83.37 BSAS SB1473 FEE 101-0000-20306 0 $3.00 $3.00 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON Total Paid for BUILDING STANDARDS ADMINISTRATION $3.00 $3.00 BSA: RESIDENTIAL, EA ADDITIONAL 1,000SF 101-0000-42403 0 $68.45 $68.45 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON RESIDENTIAL, EA ADDITIONAL 1,000SF PC 101-0000-42600 0 $28.20 $28.20 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $161.00 $161.00 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON Printed: Monday, April 24, 2023 12:34:56 PM 2 of 10 CRWSYSTEMS Permit Details PERMIT NUMBER City of La Quinta BRES2021-0198 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ ■ PAID BY CLTD BY RESIDENTIAL, FIRST 1,000SF PC 101-0000-42600 0 $53.13 $53.13 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON Total Paid for ELECTRICAL - NEW CONSTRUCTION 2019: $310.78 $310.78 OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $40.25 $40.25 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $40.25 $40.25 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON VENT FAN 101-0000-42402 0 $134.20 $134.20 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON VENT FAN PC 101-0000-42600 0 $53.70 $53.70 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON Total Paid for MECHANICAL 2019: $268.40 $268.40 FIXTURE/TRAP 101-0000-42401 0 $335.50 $335.50 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON FIXTURE/TRAP PC 101-0000-42600 0 $335.50 $335.50 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.42 $13.42 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.83 $26.83 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.42 $13.42 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.42 $13.42 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON Total Paid for PLUMBING 2019: $738.09 $738.09 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 Printed: Monday, April 24, 2023 12:34:56 PM 3 of 10 CRWSYSTE S Permit Details PERMIT NUMBER City of La Quinta BRES2021-0198 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ ■ PAID BY CLTD BY REMODEL, EA ADDITIONAL 500SF 101-0000-42400 0 $241.50 $241.50 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON REMODEL, EA ADDITIONAL 500SF PC 101-0000-42600 0 $193.20 $193.20 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON REMODEL, FIRST 100SF 101-0000-42400 0 $54.74 $54.74 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON REMODEL, FIRST 100SF PC 101-0000-42600 0 $149.73 $149.73 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON Total Paid for REMODEL 2019: $639.17 $639.17 SMI - RESIDENTIAL 101-0000-20308 0 $9.75 $9.75 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES C ECON Total Paid for STRONG MOTION INSTRUMENTATION SMI: $9.75 $9.75 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 7/7/21 WEB8690 07383J CREDIT VINCERE INDUSTRIES INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 NEW CONSTRUTION - SINGLE FAMILY RESIDENTIAL 101-0000-42400 0 $161.00 $161.00 7/7/21 1VINCERE WEB8690 07383J CREDIT INDUSTRIES INC ECON Total Paid for ZONING CLEARANCE - PLANNING PLAN CHECK: $161.00 $161.00 TOTALS: $2,239.56 $2,239.56 11 INSPECTION ir SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES Printed: Monday, April 24, 2023 12:34:56 PM 4 of 10 CRWSYSTEMS Permit Details City of La Quinta TEMPORARY POWER BLD gated, need name for guard 8/18/2022 8:26 AM VINCERE INDUSTRIES INC I would like to schedule ahead of time, if possible for Monday 22nd Contact Name: VINCERE INDUSTRIES INC Site Address: 49641 AVILA DR Phone: 7609044120 e-Mail: projects@vincereindustries.com UNDERGROUND PLBG AMOR 7/19/2021 7/19/2021 APPROVED FOOTINGS AMOR 7/19/2021 7/19/2021 APPROVED FRAMING AMOR 8/20/2021 8/23/2021 PARTIALLY APPROVED INTERIOR SHEAR NOT PART OF THIS INSPECTION ROUGH MECH AMOR 8/20/2021 8/23/2021 APPROVED ROUGH PLBG AMOR 8/20/2021 8/23/2021 APPROVED ROUGH ELEC AMOR 8/20/2021 8/23/2021 APPROVED INSULATION KKI 8/27/2021 8/27/2021 APPROVED SHOWER PAN KKI 8/27/2021 8/27/2021 APPROVED Printed: Monday, April 24, 2023 12:34:56 PM 5 of 10 CRWSYSTEMS PERMIT NUMBER Permit Details City of La Quinta ammiiiiiit BRES2021-0198 FRAMING DCL 9/3/2021 9/3/2021 DISAPPROVE D - CLEAN CONSTRUCTION WASH OUT FROM GUTTERS. NO FURTHER INSPECTIONS UNTIL RESOLVED.- SITE SPECIFIC DESIGN, PERMITTING, AND INSPECTIONS REQUIRED FOR ADDITIONAL CMU COURSES ADDED TO EXISTING PERIMETER SITE WALLS.- PROVIDE A-35 CONNECTION HARDWARE PER 28, SD-2, AT BEDROOM 2 (SOUTH NUMBER 2 SHEAR WALL).- PROVIDE A-35 CONNECTION HARDWARE PER 25, SD-2, AT HALL WAY/ BATH SEPARATION WALL (NUMBER 1 SHEAR WALL).- PROVIDE A-35 CONNECTION HARDWARE PER 23,24,25, 27, SD-2, AT WEST EXTERIOR AND SOUTH INTERIOR GARAGE SEPARATION NUMBER 1 AND 2 SHEAR WALLS.- UNABLE TO ACCESS GARAGE TO INSPECT SHEAR. ADDITIONAL CORRECTIONS MAY APPLY. FRAMING DCL 9/23/2021 9/23/2021 APPROVED W/EXCEPTIO N - ROUGH MECHANICAL INSPECTION REQUIRED FOR DUCT PENETRATION AT GARAGE. FKEX DUCT NOT PERMITTED. NO ENERGY REQUIRED FOR MINUS 40' RUN. DRYWALL NAIL KKI 10/1/2021 10/1/2021 APPROVED LATH JAN 10/4/2021 10/6/2021 APPROVED PENDING PATCH AREA AT SOUTH PART OF DWELLING ( PATCH SIZE 2'X3') REFERENCE TO ATTACHMENTS FOR PENDING AREAS COMPLETED, STATUS CHANGE TO APPROVED GAS LINE/TEST KKI 10/26/2021 10/26/2021 APPROVED FINAL** DCL 2/7/2022 2/7/2022 DISAPPROVE D - ARC FAULT PROTECTION REQUIRED THROUGHOUT SCOPED AREA. SEE APPROVED PLANS FOR ARC FAULT PROTECTED AREAS. Printed: Monday, April 24, 2023 12:34:56 PM 6 of 10 CRWSYSTEMS 6,y OF'Cl'9 Permit Details City of La Quinta PERMIT NUMBER BRE52021-0198 4111 FINAL** DCL 4/25/2022 4/25/2022 DISAPPROVE D eTRAKiT Inspection Request 4/22/2022 12:13 PM VINCERE INDUSTRIES INC Contact Name: VINCERE INDUSTRIES INC Site Address: 49641 AVILA DR Phone: 7609044120 e-Mail: projects@vincereindustries.com - ARC -FAULT PROTECTION IS REQUIRED FOR ALL NEW AND MODIFIED CIRCUITS AND OUTLETS. THIS INCLUDES LIGHTING AND SMOKE ALARM OUTLETS. PROVIDE PROTECTION FOR GUEST BEDROOM, LAUNDRY/UTILITY, BEDROOM 3, HALLWAYS, MOVIE ROOM, KITCHEN, FAMILY ROOM, DINING ROOM,GREAT ROOM, BAR AREA, MASTER BEDROOM, MASTER CLOSETS, BEDROOM 4, AND BEDROOM 2. REFER TO PLAN SHEET E-1 FOR ARC -FAULT LOCATION CALL OUTS, AND ELECTRICAL NOTE 1 DETAILING REQUIRED AREAS. FINAL** DCL 7/14/2022 7/14/2022 DISAPPROVE D Inspector BBL changed the inspection assignment from BBL to DCL Printed: Monday, April 24, 2023 12:34:56 PM 7 of 10 CRWSYSTE S Permit Details City of La Quinta PERMIT NUMBER BRE52021-0198 4111 FINAL** DCL 7/14/2022 7/14/2022 DISAPPROVE D - PREVIOUS CORRECTIONS FOR ARC -FAULT REMAIN UNRESOLVED. - CONTRACTOR TO SUBMIT REVISED ELECTRICAL PLAN FOR REVIEW, INDICATING ONLY SPECIFIC AREAS WHERE NEW CONSTRUCTION OR ALTERATIONS TRIGGERED AN ARC -FAULT PROTECTION REQUIREMENT.- ALTERATIONS TO ELECTRICAL AT BEDROOM 2 AND ALL NEW ELECTRICAL AT GUEST BEDROOM AREA REQUIRE ARC -FAULT PROTECTION. NOTE THAT ARC -FAULT PROTECTION IS REQUIRED FOR ALL NEW AND ALTERED CIRCUITS/OUTLETS IN THESE AREAS. OUTLETS INCLUDE BUT ARE NOT LIMITED TO: RECEPTACLES, LIGHTING OUTLETS, AND SMOKE ALARM OUTLETS.- REINSPECTION FEE ASSESSED FOR RETURN TRIP REQUIRED FOR INSPECTION. PLEASE ADDRESS FEE AND OBTAIN APPROVAL FOR REVISED PLAN PRIOR TO REQUESTING REINSPECTION. FINAL** JAN 8/22/2022 8/22/2022 APPROVED gated community 8/18/2022 10:29 AM VINCERE INDUSTRIES INC Call with inspectors name to leave at gate Contact Name: VINCERE INDUSTRIES INC Site Address: 49641 AVILA DR Phone: 7609044120 e-Mail: projects@vincereindustries.com PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RE DATEED STATUS REMARKS NOTES 1ST BLDG NS — ETRAKIT (2 WI() JAKE FUSON 4/14/2021 4/28/2021 5/12/2021 REVISIONS REQUIRED SEE 1ST REVIEW CORRECTION LIST. Printed: Monday, April 24, 2023 12:34:56 PM 8 of 10 CRWSYSTE S Permit Details PERMIT NUMBER City of La Quinta BRES2021-0198 JIla oh 1ST FIRE ETRAKIT (1 WK) KOHL HETRICK 4/14/2021 4/21/2021 4/20/2021 NOT REQUIRED EXISTING / NONSPRINKLERED 1ST PERMIT TECH — ETRAKIT (1 DAY) PERMIT TECH BUCKET 4/14/2021 4/15/2021 4/15/2021 COMPLETE COULD NOT RENAME DESCRIPTION OF ENERGY 1ST PLANNING — ETRAKIT (1 WK) SIJIFREDO FERNANDEZ 4/14/2021 4/21/2021 4/19/2021 READY FOR APPROVAL 2ND BLDG NS — ETRAKIT (1 WK) JAKE FUSON 6/7/2021 6/14/2021 6/28/2021 APPROVED BOND INFORMATION ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/14/2021 EtrakitContractor 1ST SUBMITTAL PLANS Full Set of architectural dwg.pdf 1 DOC 4/14/2021 EtrakitContractor Title 24's 1R 004 49641 AVILA DR (Signed).pdf 1 DOC 6/7/2021 EtrakitContractor 2ND SUBMITTAL PLAN SET Full Set of architectural dwg_1.pdf 1 DOC 6/7/2021 EtrakitContractor 2ND SUBMITTAL STRUCTURAL CALCULATIONS CALC 49641 AVILA DR LQ CANDY.pdf 1 DOC 6/7/2021 EtrakitContractor ASBESTOS REPORT 1522038 Asbestos Report.pdf 1 DOC 6/7/2021 EtrakitContractor 2ND SUBMITTAL ENERGY REPORT 1R - 004 - 49641 AVILA DR (Signed)_1.pdf 1 DOC 6/7/2021 EtrakitContractor 2ND SUBMITTAL RESPONSES BRES2021-0198 - 1ST REVIEW CORRRECTION LIST (Answered).pdf 1 DOC 5/12/2021 JAKE FUSON 1ST REVIEW CORRRECTION LIST BRES2021-0198 - 1ST REVIEW CORRRECTION LIST.pdf 1 Printed: Monday, April 24, 2023 12:34:56 PM 9 of 10 CRWSYSTE S Permit Details Ai City of La Quinta PERMIT NUMBER BRES2021-0198 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/28/2021 JAKE FUSON CERTIFICATION OF BUILDING AREA BRE52021 0198- CERTIFICATION OF BUILDING AREA.pdf 1 DOC 6/28/2021 JAKE FUSON APPROVED PLAN SET BRES2021-0198 - APPROVED PLAN SET.pdf 1 DOC 6/28/2021 JAKE FUSON APPROVED STRUCTURAL CALCULATIONS BRES2021-0198 - APPROVED STRUCTURAL CALCULATIONS.pdf 1 DOC 6/29/2021 JAKE FUSON SCHOOL FEE CERTIFICATE OF COMPLIANCE BRES2021-0198 - SCHOOL FEE CERTIFICATE OF COMPLIANCE.PDF 1 DOC 7/8/2021 JAKE FUSON RFI UPDATED NOMINAL WIDTHS OF HEADERS BRES2021-0198 - RFI - UPDATED NOMINAL WIDTHS OF HEADERS.pdf 1 Printed: Monday, April 24, 2023 12:34:56 PM 10 of 10 CRWSYSTEMS Date: 6/28/2021 No.: 21-02069-1 Owner: Canady Family Trust Address: 49641 Avila Dr City: La Quinta Type: Residential Addition < 500 sq ft Lot # Street No. 49641 Comments: CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760)771-8515 Email: Jurisdiction: La Quinta Tract #: Street Name Sq. Feet APN Avila Dr. 160 646-280-001 Co):3 DESERT SANDS UNIFIED SCHOOL DISTRICT Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less Exempt This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 160 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: Exempt- Mark Zimmer Bank Name/Recipient of Certificate By Scott L. Bailey Superintendent Check No.: Telephone: Funding: Exempt Fee Collected/ Exempted Y: Yazmin Henry Certificate Fees Due: Original Payment(s) Rec'd: New Payment Rec'd: Over/Under: $0.00 $0.00 $0.00 $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: This EXEMPTION document has been emailed to recipient and therefore, this document is valid WITHOUT the Embossed Seal. 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/1/2022 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: BUILDING RESIDENTIAL (WEB)/ADDITION BRES2021-0198 49641 AVILA DR 646280001 CANADY / 160SF GARAGE CONVERSION TO GUEST BEDROOM + REMODEL $75,000.00 Owner: CANADY FAMILY TRUST 49641 AVILA DR LA QUINTA, CA 92253 Applicant: GABRIEL LUJAN 77530 Enfield Ln. Palm Desert, CA 92211 Contractor: VINCERE INDUSTRIES INC 30670 HILL DRIVE THOUSAND PALMS, CA 92276 (760)904-4120 LIc. No.: 968718 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B, C36 License No.: 968718 Date: Contractor: OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (___) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (___) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (___) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:_______________________________________________ Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: SECURITY NATIONAL INSURANCE COMPANY Policy Number: SWC1379060 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Date: 9/1/2022 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: BRES2021-0198 49641 AVILA DR 646280001 CANADY / 160SF GARAGE CONVERSION TO GUEST BEDROOM + REMODEL $75,000.00 Owner: CANADY FAMILY TRUST 49641 AVILA DR LA QUINTA, CA 92253 Applicant: GABRIEL LUJAN 77530 Enfield Ln. Palm Desert, CA 92211 Contractor: VINCERE INDUSTRIES INC 30670 HILL DRIVE THOUSAND PALMS, CA 92276 (760)904-4120 LIc. No.: 968718 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -Detail: CANADY / 160SF GARAGE CONVERSION TO GUEST BEDROOM, RECONFIGURE VARIOUS WALLS, CREATE (3) NEW BATHROOMS, VARIOUS NEW DOORS AND WINDOWS, NEW ELECTRICAL & PLUMBING FIXTURES AT RESIDENCE AND EXISTING GAZEBO [ENGINEERED]. THIS PERMIT DOES NOT INCLUDE ALTERATION OF THE FIREPLACES NOR REPLACEMENT OF THE ELECTRICAL SERVICE PANEL, WATER HEATER OR HVAC SYSTEM. 2019 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT RE-INSPECTION FEE 101-0000-42400 0 $83.37 Total Paid for ADMINISTRATIVE: $83.37 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $3.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $3.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITIONAL 1,000SF 101-0000-42403 0 $68.45 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITIONAL 1,000SF PC 101-0000-42600 0 $28.20 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $161.00 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF PC 101-0000-42600 0 $53.13 Total Paid for ELECTRICAL - NEW CONSTRUCTION 2019: $310.78 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT 101-0000-42402 0 $40.25 DESCRIPTION ACCOUNT QTY AMOUNT OTHER MECHANICAL EQUIPMENT PC 101-0000-42600 0 $40.25 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $134.20 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $53.70 Total Paid for MECHANICAL 2019: $268.40 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $335.50 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $335.50 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $13.42 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 1-4 OUTLETS PC 101-0000-42600 0 $26.83 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.42 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.42 Total Paid for PLUMBING 2019: $738.09 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500SF 101-0000-42400 0 $241.50 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, EA ADDITIONAL 500SF PC 101-0000-42600 0 $193.20 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100SF 101-0000-42400 0 $54.74 DESCRIPTION ACCOUNT QTY AMOUNT REMODEL, FIRST 100SF PC 101-0000-42600 0 $149.73 Total Paid for REMODEL 2019: $639.17 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $9.75 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $9.75 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUTION - SINGLE FAMILY RESIDENTIAL 101-0000-42400 0 $161.00 Total Paid for ZONING CLEARANCE - PLANNING PLAN CHECK: $161.00 TOTALS:$2,239.56