06-3496 (CONR) Title 24TITLE 24 REPORT Title 24 Report for: Additions & Renovations -to the Citrus Clubhouse Jefferson and 52nd La Quinta, CA . Project Designer: Pearson Architects, Inc. 74-260 Highway 111, Suite 8 Palm Desert, CA 92260 (760) 779-1937 Report Prepared By:' Steve Balderrama, CEPE Stueven Engineering Consultants 326 Kalmia Street Escondido, CA 92025 CITY OF LA QUINTA (760) 735-8577 BUILDING & SAFETY DEPT. FOR R CONSTRUCTION DATE 13 07 gY Job Number: JAN 1 9 2001 i Date: 1/18/2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 3429 TABLE OF CONTENTS Cover Page - 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 13 Form MECH-MM Mechanical Mandatory Measures 14 i EnergyPro 4.3 by EnergySoft Job Number: User Number: 3429 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME Additions & Renovations to the Citrus Clubhouse DATE 1/18/2007 PROJECT ADDRESS Jefferson and 52nd La Quinta The documentation preparer hereby certifies that the documentation is accu to ando te. DOCUMENTATION AUTHOR DATE OF PLANS PRINCIPAL DESIGNER - ENVELOPE Pearson Architects, Inc. TELEPHONE (760) 779-1937 Building Permit # DOCUMENTATION AUTHOR Stueven Engineering Consultants TELEPHONE 760 735-8577 Checked by/Date EnforcementAgenc Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accu to ando te. DOCUMENTATION AUTHOR DATE OF PLANS Steve Balderrama CEPE BUILDING CONDITIONED FLOOR AREA 3,030 Sq.Ft. The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION California as a civil engineer, mechanical engineer, or I am a licensed architect. NEW CONSTRUCTION ® ADDITION ❑ EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accu to ando te. DOCUMENTATION AUTHOR SIGN TUDATE Steve Balderrama CEPE r8 :) The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ R 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 CA -W& Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNA RE ILIQ-a1 NO' 2 DA :Pearson Architects Inc.' LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of Requir or PRINCIEAL LIGHTING DES1G - NAME TUR LIC. NO. _ DATE _. ME HANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ECH-1, MECH-2 MECH-3 MECH-5 Requirg,df r PRINCIPAL MECHANICAL DESIGNER - NAME SI T NO. DATE Stueven Engineering Consultants / ?/S p3 /I o '► 1 EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Paae:3 of 15 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part•2 Of 3 : PERF - PROJECT NAME ; . • DATE I . Additions & Renovations to the Citrus Clubhouse • = '1/18/2007' ANNUAL TDV ENERGY USE SUMMAR N 0 aeg Standard ENERGY COMPONENT Design Space Heating 5.84 Space Cooling 335.74 Indoor Fans 97.99 Heat Rejection 0.00 Pumps & Misc. 0.00 Domestic Hot Water 0.00 Lighting 67.76 Receptacle 43.96 Process 0.00 TOTALS: 551.28 Percent better than Standard: Y (kBtu/sqft-yr) N 0 aeg Proposed Design sp.. Hdkv Compliance Margin 1.62 4.22 314.86 20.88 106.68 -8.70 0.00 0.00 0.00 0.00 0.00 0.00 67.76 0.00 43.96 0.00 0.00 0.00 0-30* TfiO?90 120150ISO 210T240T270 300P330 kBtWsgft-yr', [[r -Standard N 0 aeg Conditioned Floor Area . Unconditioned Floor Area Conditioned Footprint Area, Fuel Type sp.. Hdkv sqft. sqft. " sqft. 1 0 sp.;, C4*V - - Natural Gas Hdfto Ratio < P-Wa 8 W= y - .• j - DIM' ! . . Ligh ft 568 sqft. 40.1% Left Elevation (E) 589 0-30* TfiO?90 120150ISO 210T240T270 300P330 kBtWsgft-yr', Building Orientation Number of Stories Number of Systems Number of Zones N 0 aeg Conditioned Floor Area . Unconditioned Floor Area Conditioned Footprint Area, Fuel Type 3,030 sqft. sqft. " sqft. 1 0 4 3,030 5 - Natural Gas Glazing Ratio Standard Proposed LEED-NC v2.2 Energy & Atmosphere Credit Lighting Power Density 1.021 W/sgft. 1.021 W/sgft. Savings vs. Title 24: Prescriptive Env. Heat Loss 965 Btu/h . 722 Btu/h EAc1 Credit: 0 Points Prescriptive Env. Heat Gain 107,931 Btu/h-F 86,974 Btu/h-F ' Remarks: • l r Run Initiation Time: 01/18/07 16:13:56 Run Code: 1169165636 EnergyPro 4.3 by EnergySoft User Number: 3429 . • Job Number:. • - - Page:4 of 15 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (N) 1,416 sqft. 568 sqft. 40.1% Left Elevation (E) 589 sqft. 123 sqft. 20.9% Rear Elevation S 1,006 sqft. 376 sqft. 37.4% V Right Elevation (WA Total Roof 565 3,576 3,030 sqft. sqft. sqft. 168 1,235 sqft. sqft. sqft. 29.7% 34.5% Standard Proposed LEED-NC v2.2 Energy & Atmosphere Credit Lighting Power Density 1.021 W/sgft. 1.021 W/sgft. Savings vs. Title 24: Prescriptive Env. Heat Loss 965 Btu/h . 722 Btu/h EAc1 Credit: 0 Points Prescriptive Env. Heat Gain 107,931 Btu/h-F 86,974 Btu/h-F ' Remarks: • l r Run Initiation Time: 01/18/07 16:13:56 Run Code: 1169165636 EnergyPro 4.3 by EnergySoft User Number: 3429 . • Job Number:. • - - Page:4 of 15 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Additions& Renovations to the Citrus Clubhouse DATE 1/18/2007 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Allowed LPD Area Tailored /s 3 (W/S4 Proc. Loads (W/Sq HP -1 and HP -2 Fitness Center Exercise, Gymnasium 1,900 '1.00 HP -3 Office Areas . Office 528 '1.20 Indoor Restrooms Corridor/Restroom/Support 122 '0.60 Outdoor Restrooms Corridor/Restroom/Support 80 '0.60 HP -4 Bar Bar, Cocktail Lounge, Casino 400 "1.10 Notes: 1. See LTG -2-C (items marked with asterisk, see LTG -2 -C by others) 2. See LTG -4-C 3. See LTG -5-C (by others) 4. See LTG -6-C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST I ne local entorcement agency snould pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "HP -3" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The HVAC System "HP -4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Signature or MWC EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Page:5 of 15 1 CERTIFICATE OF COMPLIANCE ENV -1-C PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 OPAQUE SURFACES # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond' Status Joint Appendix IV Reference Location / Comments 1 Wall 39E 0.069 R-21 R-0.0 0 90 New 09-A6 Fitness Center 2 Wall 42 0.069 R-21 R-0.0 180 90 New 09-A6 Fitness Center 3 Wall 2 0.069 R-21 R-0.0 90 90 New 09-A6 Fitness Center 4 Roof 1,90q 0.025 R-38 R-0.0 0 0 New 01-A18 Fitness Center 5 lWall 1 100 0.069 R-21 R-0.0 0 90 New 09-A6 Office Areas 6 Door 24 0.500 None R-0.0 0 90 New 28-A4 Office Areas 7 Wall 3E 0.069 R-21 R-0.0 90 90 New 09-A6 Office Areas 8 Wall 10E 0.069 R-21 R-0.0 180 90 New 09-A6 Office Areas 9 Door 24 0.500 None R-0.0 180 90 New 28-A4 Office Areas 10 Wall 3 0.069 R-21 R-0.0 270 90 New 09-A6 Office Areas 11 Roof 524 0.025 R-38 R-0.01 0 0 1 New 01-A18 Office Areas 12 lWall 1 3 0.069 R-21 R-0.0 0 90 New 09-A6 Indoor Restrooms 13 Wall 8 0.069 R-21 R-0.0 90 90 New 09-A6 Indoor Restrooms 14 Roof 12 0.025 R-38 R-0.0 0 0 New 01-A18 Indoor Restrooms 15 Wall 8 0.069 R-21 R-0.0 0 90 New 09-A6 Outdoor Restrooms 16 Wall 8 0.069 R-21 R-0.0 180 90 New 09-A6 Outdoor Restrooms 17 Wall 11 0.069 R-21 R-0.0 270 90 1 New 09-A6 Outdoor Restrooms 18 Door 41 -8q 0.5001 None I R-0.01 270 90 New 28-A4 Outdoor Restrooms 19 lRoof f 0.1381 None I R-5.0 0 0 New 01-A1 Outdoor Restrooms 20 all 21 0.069 R-21 R-0.0 0 90 New 09-A6 Bar N, E, A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's Droiect office during construction and in the buildina manaaer's office after construction # T e Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 1 Window Front N 48 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Fitness Center 2 Window Front N 48 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Fitness Center 3 Window Front (N) 48 0.390 NFRC 0.37 NFRC 0 New Metal Clad /Wood Windows Fitness Center 4 Window Front N 48 0.390 NFRC 0.37 NFRC 0 New Metal Clad /Wood Windows Fitness Center 5 Window Front N 48 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Fitness Center 6 Window Front (N) 60 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Fitness Center 7 lWindow Front N 60 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Fitness Center 8 Window Rear S 48 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Fitness Center 9 Window Rear S 48 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Fitness Center 10 Window Rear (S) 48 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Fitness Center 11 Window Rear (S) 48 0.390 NFRC 0.37 INFRC 1801 New I Metal Clad / Wood Windows Fitness Center 12 Window Rear S 48 0.390 NFRC 0.37 INFRC 1801 New I Metal Clad / Wood Windows Fitness Center 13 Window Rear (S) 48 0.390 NFRC 0.37 INFRC 1801 New I Metal Clad / Wood Windows Fitness Center (1) LI -factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 1 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 2 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 3 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 4 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 5 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 6 None 0.76 10.0 6.0 2.0 0.1 2.0 2.0 7 None 0.76 10.0 6.0 2.0 0.1 2.0 2.0 8 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 9 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 10 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 11 None 1 0.76 8.0 6.0 2.0 0.1 2.0 2.0 12 None 1 0.76 8.0 6.0 2.0 0.1 2.0 2.0 13 None 1 0.76 8.0 6.0 2.0 0.1 2.0 2.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES aThe proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 Wfft2. See Section 143(c). If this box Is checked, ENV -4-C must be filled out. when submitting under the Prescriptive Compliance Approach. 1 EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Page:6 of 15 1 CERTIFICATE OF COMPLIANCE ENV -1-C PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 OPAQUE SURFACES OEM= Area U -Fac' SHGC2 Act. Am. Cond. Stat. IV Reference Location/ Comments 14 Window Rear S 48 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Fitness Center 15 Window Left E 48 0.390 NFRC 0.37 NFRC 90 New Metal Clad / Wood Windows Fitness Center 16 Window Left E) 48 0.390 NFRC 0.37 NFRC 90 New Metal Clad / Wood Windows Fitness Center 17 Window Front N 17 0.390 NFRCI 0.37 NFRC 0 New Metal Clad / Wood Windows Office Areas 18 Window Front N 17 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Office Areas 19 Window Front N) 6 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Office Areas 20 lWindow Rear S) 17 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Office Areas 21 Window Rear S 17 0.390 NFRC 0.37 NFRC 180 New Metal Clad /Wood Windows Office Areas 22 Window Rear S 6 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Office Areas 23 Window Front N 84 0.390 NFRC 0.37 NFRCI 0 New I Metal Clad / Wood Windows Bar 24 Window Front N) 84 0.390 NFRC 0.37 NFRC 01 New Metal Clad / Wood Windows I Bar 25 Window Left E 27 0.390 NFRC 0.37 NFRC901 0.1 New I Metal Clad / Wood Windows lBar 26 Window Right W 84 0.390 NFRC 0.37 NFRC 2701 New I Metal Clad / Wood Windows jBar N. E. A. R (New, Existing, Altered, Removed) FENESTRATION SURFACES -71 More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default LI -factors from Standards Table 116-A and B. Certificate shall be filed in the contractor's Droiect office durinq construction and in the building manaoer's office after construction # IType Area U -Fac' SHGC2 Act. Am. Cond. Stat. Glazing Type Location/ Comments 14 Window Rear S 48 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Fitness Center 15 Window Left E 48 0.390 NFRC 0.37 NFRC 90 New Metal Clad / Wood Windows Fitness Center 16 Window Left E) 48 0.390 NFRC 0.37 NFRC 90 New Metal Clad / Wood Windows Fitness Center 17 Window Front N 17 0.390 NFRCI 0.37 NFRC 0 New Metal Clad / Wood Windows Office Areas 18 Window Front N 17 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Office Areas 19 Window Front N) 6 0.390 NFRC 0.37 NFRC 0 New Metal Clad / Wood Windows Office Areas 20 lWindow Rear S) 17 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Office Areas 21 Window Rear S 17 0.390 NFRC 0.37 NFRC 180 New Metal Clad /Wood Windows Office Areas 22 Window Rear S 6 0.390 NFRC 0.37 NFRC 180 New Metal Clad / Wood Windows Office Areas 23 Window Front N 84 0.390 NFRC 0.37 NFRCI 0 New I Metal Clad / Wood Windows Bar 24 Window Front N) 84 0.390 NFRC 0.37 NFRC 01 New Metal Clad / Wood Windows I Bar 25 Window Left E 27 0.390 NFRC 0.37 NFRC901 0.1 New I Metal Clad / Wood Windows lBar 26 Window Right W 84 0.390 NFRC 0.37 NFRC 2701 New I Metal Clad / Wood Windows jBar (1)LI-factor Type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING ## Exterior Shade Type SHGC Window Hgt. Wd. Overhang Left Fin Right Fin Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 14 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 15 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 16 None 0.76 8.0 6.0 2.0 0.1 2.0 2.0 17 None 0.76 10.0 1.7 2.0 0.1 2.0 2.0 18 None 0.76 10.0 1.7 2.0 0.1 2.0 2.0 19 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 20 None 0.76 10.0 1.7 2.0 0.1 2.0 2.0 21 None 0.76 10.0 1.7 2.0 0.1 2.0 2.0 22 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 23 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 24 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 25 None0.76 3.0 2.0 2.0 0.1 2.0 2.0 26 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 15 and contains an enclosed space with floor area greater than 25,000 11:2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W/ft2. See Section 143(c). If this box Is checked, ENV -0-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySofl User Number. 3429 Job Number: Paae:7 of 15 1 CERTIFICATE OF COMPLIANCE ENVA-C )ROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 OPAQUE SURFACES -71 # I surrace msuiation Act. Iona: joint Appenaix Twe Area U -Fac. Cay. Cont. Azm. Tilt Status IV Reference I Location/ Comments N, E, A, R (New, Existing, Altered, Removed) FENESTRATION SURFACES -71 More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from Stnndarrls Tnhlp 116-A and R renifiratp shall hp filpd in the rnntma tnrs nmiort nfrrp durinn r netn,rtinn and in the h,,ildinn m nor, nffirp aBpr rnnctn,rtinn (1)y -tactor type: 1lb-A Uetaull Table trom Standaros, Table NI -1 oetault Table trom the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin ## Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 27 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES U The proposed building is In climate zones Z through 15 and contains an enclosed space with Floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W111:2. See Section 143(c). H this box Is checked, ENV -0-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Page:8 of 15 1 ..Location/. (1)y -tactor type: 1lb-A Uetaull Table trom Standaros, Table NI -1 oetault Table trom the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING Window Overhang Left Fin Right Fin ## Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t. 27 None 0.76 3.0 2.0 2.0 0.1 2.0 2.0 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES U The proposed building is In climate zones Z through 15 and contains an enclosed space with Floor area greater than 25,000 ft2, a ceiling height greater than 15 feet, and an LPD for general lighting of at least 0.5 W111:2. See Section 143(c). H this box Is checked, ENV -0-C must be filled out. when submitting under the Prescriptive Compliance Approach. EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Page:8 of 15 1 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME t DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates. and ooeratino and maintenance information meet the requirements of Section 10-103(bl and Title 24 Part 6. STATEMENT OF COMPLIANCE MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 ft2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btulhr. -Water-loop Heat Pump Controls Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Page:9 of 15 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C (PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 SYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economiier Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance AIR SYSTEMS, Central or Single Zone HP -1 and HP -2 HP -3 HP -4 2 1 1 Reference on Plans or Specification 1 112(a) 7.50 HSPF 8.50 HSPF 8.80 HSPF 112(a) 10.3 EER 14.5 SEER / 11.5 EER 14.0 SEER / 11.5 EER 112(b) Yes Yes Yes 112(c), 115(a), n/a n/a n/a 121(b) No No No 121 b) 760 cfm 110 cfm 200 cfm 121 c No No No 121(c) No No No 121(c), 122(e) Programmable Switch Programmable Switch Programmable Switch 122(e) Heating & Cooling Required Heating & Cooling Required Heating & Cooling Required 122 Gravity Gravity Gravity 122(g) n/a n/a n/a 123 124 R-8.0 R-8.0 R-8.0 144 a & b n/a n/a n/a 144 a & b 59,959 btuh 13,741 btuh 17,550 btuh 144 a & b n/a n/a n/a 144 a & b 101,675 btuh 26,943 btuh 40,711 btuh 144 c Constant Volume Constant Volume Constant Volume 144 c 144 c 144 d No No No 144 a No Economizer No Economizer No Economizer 144 Constant Ternp Constant Ternp Constant Tem 144 (f) Constant Temp Constant Temp Constant Temp 144 (k) No No No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. EnergyPro 4.3 by EnergySoft User Number: 3429 Job Number: Page: 10 of 15 1 MECHANICAL VENTILATION MECH-3-C PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1 1/18/2007 PRESCRIPTIVE REHEAT LIMITATION Section 144 d MECHANICAL VENTILATION Section 121 W2) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H I J K L M N ZONE/SYSTEM o ND3 'f1 N a v01c Uf C IN '-n 3 °0 c 3 W X>0 0' -n 3 -p c ID 3 0 Cr o M ff1 T 3 Cr 3 m X no TAT v 3 m )p O X °< ' D < c>3 (D -n .. N 3DB N o , neo -n fq "" g cM o '" -n 00 X 'pA x ;K n o c wad O X nyo T? to y :°> 'O 2.5 d > D Fitness Center 1,90 0.15 285 760 760 HP -1 and HP -2 Total 760 760 Office Areas 526 0.15 79 79 79 Indoor Restrooms 122 0.151 18 18 18 Outdoor Restrooms 8C 0.15 12 12 12 HP -3 Total 110 110 Bar 40C 0.50 200 200 200 HP -4 Total 200 200 C Minimum ventilation rate per Section 121 Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load foregress purposes fors aces without fixed seating. H Required Ventilation Air REQ'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supplycfm Fan CFM) x 30%; or K Condition area ft. sq. x 04 cfm/ft. sq.: or L Maximum of Columns H, J. K, or 300 cfm M This must be less than orequal to Column L and greater that orequal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M), column H - M. EnergyPro 4.3 by Energysoft User Number. 3429 Job Number: Page: 11 of 15 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Additions & Renovations to the Citrus Clubhouse DATE 1/18/2007 :] CHILLER AND TOWER SUMMARY HP Type Efficiency Tons Buried PUMPS Equipment Name Equipment Type Qty. Tot. Qty GPM I BHP Motor Eff. Drive Eff. Pump Control CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qtv Output Aux. kW Eff. Output Efficiencv Condition Status Economizer Type Carrier 38A0007 / 40RM0008 Split DX 2 48,000 0.0 7.50 HSPF 72,90010.3 EER New No Economizer BOILER SUMMARY Split DX Energy Standby TANK INSUL. Rated 1 Vol. Condition Factor Loss or Ext. System Name System Type Distribution Type Qty Input (Gals.) Status I or RE Pilot I R -Val. MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qtv Output Aux. kW Eff. Output Efficiencv Condition Status Economizer Type Carrier 38A0007 / 40RM0008 Split DX 2 48,000 0.0 7.50 HSPF 72,90010.3 EER New No Economizer Carrier 25HCA436 / FX4CNF036 Split DX 1 22,000 0. 8.50 HSPF 31,100 14.5 SEER/ 11.5 EER New No Economizer Carrier 25HCA448 / FX4CNF048 Split DX 1 28,100 0. 8.80 HSPF 45,20014.0 SEER/ 11.5 EER New No Economizer ENVELOPE MANDATORY MEASURES' ENV -MM PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 DESCRIPTION Desi ner Enforcement FX §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. 0 § 118(c) All Insulating Materials shall be Installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. X❑ §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. X] §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows installed shall have air Infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. • i §118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number: User Job Number: Page: 13 of 15 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 DESCRIPTION Desi ner Enforcement Equipment and Systems Efficiencies a §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. ❑ § 115(a) Fan type central furnaces shall not have a pilot light. ❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. X] § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. X] § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint ❑ § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(aft) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. 0 § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySok User. Number: User Job Number: Page: 14 of 15 MECHANICAL MANDATORY MEASURES Part 2 of 2' MECH-MM PROJECT NAME DATE Additions & Renovations to the Citrus Clubhouse 1/18/2007 t V, a Description Designer Enforcement Ventilation FX§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. F-], § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or X] § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or ❑ § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or a§ 121(f)4 Another method approved by the Commission. Service Water Heating Systems §113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. X❑ § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number: User Job Number. Page: 15 of 15 t V, a