BSOL2020-0003 Solar PlansJURISDICTIONAL NOTES: Fj UTY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 2-BY GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING 1. 2019 CA BUILDING CODE 2. 2019 CA ELECTRICAL CODE 3. 2019 CA FIRE CODE 4. 2019 CA RESIDENTIAL CODE 5. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: PV 0.0 - COVER SHEET PV 1.0 - SITE PLAN S 1.0 - MOUNT DETAILS E 1 - ELECTRICAL DIAGRAM E 2 - ELECTRICAL NOTES E 3 - WARNING LABELS E 4 - WARNING LABEL LOCATIONS E 5.0 - ELEC PANEL PHOTOS E 5.1 - ELEC MSP/STICKER PHOTOS GENERAL ELECTRICAL NOTES: GENERAL STRUCTURAL NOTES: ••'`` vt C''••,, ���� �L� ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING ��` y� �� & Cy MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOFSMOUNTED THE ROCK -IT SYSTEM BY ECOFASTEN. THE MOUNTING FEET ARE TO BE •` SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SPACED AS SHOWN IN THE DETAILS, AND SHOULD BE STAGGERED, WHERE THE ROOF SURFACE. POSSIBLE, TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE ADDITIONAL LOAD. %ramp 9Tgf� CORRECTED ON INSTALLATION. s rrr b. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE /6 LAG rri Od SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE SCREWS WITH A MINIMUM OF 2Y" PENETRATION INTO ROOF FRAMING.►�e���i �t�ti�N'� 1 RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE G. THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM. a INVERTER. RAPID SHUTDOWN COMMENCES;UPON LOSS OF UTILITY SOURCE d. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM. VOLTAGE. e. GROUND SNOW LOAD = 0 psf - f SEE *E 1.0 AND `E 2.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND f. WIND SPEED = 130 mph SPECIFICATIONS. 9. EXPOSURE CATEGORY = C •.r vivint.Solar f PHOTOVOLTAIC SYSTEM SPECIFICATIONS. 1800ASHTON BLVD, LEHI, UT84043 1.877.404.4129 SYSTEM SIZE - 8.000kW DC 17.227kW CEC AC CA LICENSE: B/C46/C10/C39-973756 MODULE TYPE & AMOUNT - (25) Hanwha Solar Q.PEAK DUO BLK-G5 320w WITH 25 SolarEdge P340 OPTIMIZERS JACOBS RESIDENCE MODULE DIMENSIONS - L/W/H 66.34"/ 39.37"/ 1.26" 50INT , CA, 92 DR ■ ( ) LA QUINTA, CA, 92253-9011 INVERTER - (1) SolarEdge Technologies SE760OH-USOOOBNC4 * UTILITY ACCOUNT #: 50688654 "INVERTER USED IN THIS DESIGN IS COMPLIANT WITH CEC 69012 (RAPID SHUTDOWN). SEE MANUFACTURER DATA SHEET. INTERCONNECTION METHOD (GRID -TIED) - LOAD BREAKER iSERVICE #:S-6279294 f REGIONAL P V\/ 0.0 MT R / OPEATING CENTER: CA-21 - - COVER SHEET 40 � 7- f� 00 I Z BY: BDATE: 20 ul � �! � DRAWN BY: RENT PERSCHON PV STRING-(S): OOF SECTIC 1 SLOPE-23 ® #1)13 MODULES AZIMUTH - 211.4 ® MATERIAL - TILE - #2)12 MODULES CURVE 2 SLOPE-23 AZIMUTH - 211.4 MATERIAL - TILE - S-CURVE SITE PLAN SCALE: 1/8" =1'-0" w co Z3 O 2 u- O H Z O of u- ROOF FIRE SUPPRESSION SPRINKLER SYSTEM: NO TOTAL ROOF AREA: 4282ft TOTAL MODULE AREA: 453ft2 TOTAL AREA COVERED: 11 % SYSTEM LEGEND PV SYSTEM SIZE: NEW 8.000kW DC I 7.227kW CEC AC EXISTING EXTERIOR MAIN SERVICE PANEL & POINT OF INTERCONNECTION. TIED TO ATTACHE[ UTILITY METER 1 B4SORD-114726. NEW PV SYSTEM AC DISCONNECT (RSD). LOCATE[ Q WITHIN 10' OF MSP. 1 NEW PV SYSTEM INVERTER: SolarEdge Technologies SE760OH-USOOOBNC4 (RSD EQUIPPED) 25 NEW HANWHA SOLAR Q.PEAK DUO BLK-G5 320W MODULES. NEW SOLAREDGE P340 OPTIMIZERS, MOUNTED ON THE BACK OF EACH MODULE. NEW PV CONDUIT RUN.'SEE E1-0 CONDUIT SCHEDULE —_—_— EXTERIOR RUN — — — — — = ATTIC RUN NEW JUNCTION BOX. (MOUNTED TO PV MODULE) �� .►����rO't�Callf��i� Sell sad Co(%-0%% y�1111111111 % FIRE CODE OFFSET RIDGE: 36"1 PATHWAY: 36" vivint.Solar 1.877.404.4129 CA LICENSE: B/C46/C10/C39-973756 JACOBS RESIDENCE 50485 VERANO DR LA QUINTA, CA, 92253-9011 UTILITY ACCOUNT #: 50688654 SERVICE #: S-6279294 REGIONAL Pv 1.0 OPERATING CENTER: GA-21 DATE: 2.3.2020 DRAWN BY: BRENT PERSCHON MOUNTING LEGEND S-CURVE TILE -ROCK-IT SLIDE EPUM BONDED WASHER FORMS WATERTIGHT SEAL TILE BASE 2' EMBEDMENT RAIN BUSTER IS APPLIED TO THE UP -SLOPE EDGE OF THE TILE BASE AS WELL AS TO THE LOCATIONS OF THE LAG SCREW. (2) MIN J" DIAM SS LAG SCREW TORQUE=13t2 FT-LBS. PILOT HOLE BACKFILLED WITH SEALANT PRIOR TO LAG INSTALLATION 1 ROCK -IT MOUNT DETAIL ry 1.i1 NOT TO SCALE ROCK -IT COUPLING MID CLAMP ROCK-IT--� COUPLING SHELF ISOMETRIC VIEW U L LISTING FOR ECOFASTEN: 2703 WEIGHT: 2.3 lb .ANDSCAPE=MAX 48" (4'-0") PORTRAIT=MAX 48" (4'-0") COUPLING—, CLAMP MODULE 3" RAFTER 3 ILSCO SGB-4 GROUNDING LUGS 1772F NOT TO SCALE TRUSS 2"x4" AT 24" O.C. e1.04PV SYSTEM MOUNTING DETAIL NOT TO SCALE 3" MIN AND 6" MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE PV MODULE, TYP. MOUNT TO FRAMING OF EXISTING ROOF TYPE, PARALLEL S 1.0 WITH PLANE OF ROOF 6'- MAXIMUMS 6 PV ARRAY TYP, ELEVATION S 1.0 NOT TO SCALE FLASHING/TILE STRAP 11*1WIilI. �QCK-IT COUPLING ASSEMBLY NOT TO SCALE • CLAMP + ATTACHMENT COUPLINGn Fes` ROCK -IT 3.0 COUPLING MID CLAMP COUPLING SHELF � 5/16"x1 1 /2" HEX FLANGE BOLT SIDE VIEW 300 SERIES SS PERMITTED CLAMP SPACING RAFTER MODULE MODULE s MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE ONE HOLE STEEL STRAP CONDUIT CONDUIT MOUNT BRACKET CONDUIT MOUNTING DETAIL S 1.0 NOT TO SCALE CLAMP + ATTACHMENT r COUPLING 1 1 2- r-TILE ROOF TOP RAFTER 18s r:4101.111 `tt`�� CI�Callfo ,,, � '° � X �0.973r.+�,- �� MrrMN e� t► "'*Nd cap' MOUNT DETAILS SCALE: NOT TO SCALE 1.877.404.4129 L CA LICENSE: B/C46/C10/C39-973756 J JACOBS RESIDENCE 50485 VERANO DR LA QUINTA, CA, 92253-9011 UTILITY ACCOUNT #: 50688654 SERVICE #: S-6279294 REGl01 k r OPERATING CENTER: CA 2S. O1 DATE: 2.3.2020 DRAWN BY: BRENT PERSCHON SolarEdge SE760OH-US STRING 2: 12 PV MODULES W/OPTIMIZERS STRING 1: 13 PV MODULES W/OPTIMIZERS 25 PV M Photovoltaic System Conduit Conductor Schedule (Unless Otherwise Specified Conductors Shall be Copper) DC System Size (Watts) 8000 Tag Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size AC System Size (Watts) 7351 1 DC -to -DC Converter Output (PV Wire) 12 AWG 2(V+, V-) B/R Free Air N/A Total Module Count 25 1 EGC (Bare) 6 AWG 1 BARE Free Air N/A 2 DC -to -DC Converter Output (THWN-2) 12 AWG 4(2V+, 2V-) B/R EMT 1/2" 2 1 EGC (THWN-2) 12 AWG I 1(GRN) EMT 11121, 3 Inverter Output (THWN-2) 8 AWG 3(1-1, L2, N) B/R/W EMT 3/4" 3 1 EGC(THWN-2) 10AWG 1(GRN) EMT 3/4" Rapid Shutdown nl�— —'t n Disconnect �tt,�•� Ct ca/it" 1 2"0" 975 ed C00010�*11ti 4,041181111111010 It m 'n of V) W U 0 N 00 W y O o v Z Q Ln Ln < U c w Q :3 > H o ^ Z U 0 u1 Q u o ,n Q -J 0) N ai It � O O � U U W r; r` Cq ci! ko J A u v7 z w Point of Interconnection, Load Z > c0 n rn Side 705.12(B)(2)(3)(b) > Z W w w J w J W Ln Z N Z Q N U �D Existing Cutler Hammer SHEET 240V/200AService Panel, Single Phase, with 200A NAME: Main Disconnect- NOT CENTER FED - tw C c 3 J M M C SHEET NUMBER: rq IW Optimizer SolarEdge P340 DC Input Power 340 Watts DC Max. Input Voltage 48 Volts DC Max. Input Current 13.75 Amps DC Max. Output Current 15 Amps Max. string rating inverter dependent. See SE documents. Inverter Make/Model SolarEdge SE760OH-US CEC Efficiency 99 AC Operating Voltage 240 Volts Cont. Max Output Current 32 Amps DC Max Input Current 20 Amps Input Short Circuit Current 45 Amps Max Output Fault Current 40 A/20 ms Other Notes PV Module Rating @ STC Module Make/Model Hanwha Q.PEAK DUO BLK-G5 320 Max. Power -Point Current (Imp) 9.47 Amps Max. Power -Point Voltage (Vmp) 33.8 Volts Open -Circuit Voltage (Voc) 40.56 Volts Short -Circuit Current (Isc) 9.94 Amps Max. Series Fuse (OCPD) 20 Amps Nom. Max. Power at STC (Pmax) 320 Watts Max. System Voltage 1000 V (IEC) (UL) Voc Temperature Coefficient -0.28 %/C AC Output Current According to art. 690.8(B)(1) 32 Amps Nominal AC Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2017 data tables. AHJ Provided Data - Max Temp: 47 °C Min Temp: -7.4 °C Power Production Calculation Main Bus Rating: 200 Amps Main Service Breaker Rating: 200 Amps PV Breaker Rating: 40 Amps 200A + 40A <= 200 x 1.2; 240 <= 240A, OK • Designed according to and all code citations are relevant to the 2019 California Electrical Code. • Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet. • All inverters installed in California are Rule 21 Utility interactive compliant. • Array grounding and bonding designed in compliance with 690.47(A). • All terminations and conductors listed for use at 75°C Conductor Calculations Wire gauge calculated from 310.15(B)(16) & (17) with ambient temperature calculations from wrn u 310.15(B)(2)(a) & 310.15(B)(3)(c) and raceway fill adjustments from 310.15(B)(3)(a). Conduit on o Cn the roof shall be installed no less than 1" above the roof deck, -0 z < "Under Array" conductors use the 90°C ampacity in 310.15(B)(17) with relevant ambient a, W p[ W < temperature adjustments. 0 >Ln z PV Circuit conductors use the larger ampacity in 310.15(B)(16) or (17) using the 75°C column with o 0 the continuous duty uprating or the 90°C column with the relevant ambient temperature and 0 raceway fill adjustments and without the continuous duty uprating per 690.8(B). Non-PV Circuit conductors use the ampacity in 310.15(B)(16) in the 75°C column or the 90'C column with the relevant ambient temperature and raceway fill adjustments, whichever is less (110.14(C) & 310.15(A)(2)). The rating of the conductor after adjustments shall be greater than, or equal to, the continuous duty uprated current. More information about conductor calculations can be provided upon request. Calc. Ex: Wire Ampacity x Ambient Temp. Corr. Factor x Conduit Fill Adj. Factor >= Output Current (Tag 1 Under Array): DC -to -DC Converter Output: 12 AWG rated 40 A, 40 A x 0.82 x 1 = 32.8 A >= 15 A o (Tag 2 On Roof): U) DC -to -DC Converter output: 12 AWG rated 30 A, 30 A x 0.82 x 0.8 = 19.68 A 7= 15 A 0 (Tag 3 Exterior); Inverter Output: 8 AWG rated 50 A, 50 A >= 40 A ■ ■ OCPD Calculations Breakers sized according to continuous duty output current. PV circuit nominal current based off inverter continuous output current X (1.25[art. 690.8(A)]). Inverter 1: SE760OH-US Max Output = 32 A x 1.25 [art. 690.8(A)) = 40 A <= 40 A (OCPD) system output current w/ continuous duty = 40 <= 40A (System OCPD) ••,4Oct COO rn N 0 0 v 09 r-i LU w m z w J J H ut Z SHEET NAME: 66 Ln to 00 00 LO 0 u, C 7 0 u v U Ln rn r` m r` m ui V) Z 0) W 0) U N J � r\ Uw +a a°Jo Z a (SHEET 1 NUMBER: N W Conduit, Raceways, and J-Boxes (Labeled Every 10') per 690.31(G)(3) & (4) Interactive System Point of Interconnection per 690.54 Plaques and Directories at the Service Equipment (MSP) and the Location of All System Disconnects per 690.56(B) & 705.10 SE760OH-US String 2 DC Disco PV System Disconnects per 690.13(B) PV SYSTEM DISCONNECT • •^ •1 •I� WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Power Source Output Connection, Adjacent to Back - fed Breaker per705.12 Mk . S1111411TWO. •� RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PV With Rapid Shutdown, Installed Within 3 ft of the Service Disconnecting Means per 690.56(C)(1)(a) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN 1 SWITCH TO THE SOLAR EIVTXX "OFF" POSITION TO FAgELS SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SHALL BE WEATHER -RESISTANT, PERMANENTLY ETCHED PLACARDS. HANDWRITTEN SIGNS WILL. NOT BE ACCEPTABLE. 690.53 will .�'`%0+ot'CalliS . GjD i iui�'■•- v m Ln Ln l0 00 u N W N O z Q Ln v <LU U GJ > Q O Ln z U U ,J o Ef Y Ln J y� I_ v U rn N -i � o o lz� U n o� � n DO JO U N f �O w z CO n M > rn z s W w w w J J W J J U N L.n N J z z u "0 SHEET NAME: SHEET NUMBER: MAIN BREAKER DE -RATED TO*** DUE TO SOLAR PHOTOVOLTAIC AC POWER SOURCE PHOTOVOLTAIC DC POWER SOURCE DISCONNECT 1 CIRCUITS 4 RATED AC OUTPUT CURRENT: *** A MAXIMUM VOLTAGE: ***A value calculated for each m Ln EVERY MAX OF ***AMPS PV SOURCE ALLOWED NOM. OPERATING AC VOLTAGE: *** V MAXIMUM CURRENT: ***V account, for specific value see the a( 0 N 00 DO NOT INCREASE MAIN BREAKER RATING Property of Vivint Solar DC -TO -DC CONVERTER MAXIMUM RATED OUTPUT CURRENT: ***A previous warning label page v 0 m 1Oo Property of Vivint Solar Property of Vivint Solar a a u Y 5 WARNING: PHOTOVOLTAIC POWER SOURCE w Q � 2 WARNING Property of Vivint Solar SITE PLAN PLACARD SHOWING ADDITIONAL POWER SOURCE -0 L z o ELECTRICAL SHOCK HAZARD o 0 Q TERMINALS ON THE LINE AND LOAD SIDES MAY BE G AND DISCONNECT LOCATIONS. PLACARD SHALL BE O ENERGIZED IN THE OPEN POSITION V POWER SOUR E OUT UT CONNECTION MOUNTED ON EXTERIOR OF ELECTRICAL PANEL `" g +, Property of Vivint Solar Property of Vivint Solar P Y DO NOT RELOCATE THIS OVERCURRENT DEVICE PV SYSTEM DISCONNECT Property of Vivint Solar 3 Property of Vivint Solar 10 PV rapid shutdown label required by 7 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(1) indicated on E.3 Property of Vivint Solar L rQ �sµ1f111rrr�� Callf &* N m r 0 _CU fu (10) U N �''�•ad Cfln�•`''•ru IF APPLICABLE ROOFTOP ARRAY 7 7 INSIDE PANEL 6 INSIDE PANEL 6 9 $ 2 3 2 3 4 4 1 IF APPLICABLE 5 � GsF���a Q0 "t IF APPLICABLE DC M M 5 DISCONNECT INSIDE --- —7r-- JUNCTION BOX 0 SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINTSOLAR METER (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) INTEGRATED WITH (WHERE REQUIRED) ARRAY) TYPICAL SOLAR GENERATION INSTALLATION (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) VISIBLE/LOCKABLE A/C DISCONNECT SUB PANEL (WHEN REQUIRED) MAIN SERVICE DISCONNECT PANEL ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT -CURRENT (DC) CONDUIT, ENCLOSURES, BE REFLECTIVE_, THEY SHALL. CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND RACE -WAYS, CABLE ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. ALL PLACARDS SERVICE TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT {3048 MM), ABOVE SHALL BE WEATHER -RESISTANT, PERMANENTLY ETCHED PLACARDS. HANDWRITTEN SIGNS WILL AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. NOT BE ACCEPTABLE. m N r1 �rI U n oZ J= JJ _ U LA O 6� W w Ln Z m r, rn M z w �c N LU Uj J J LJJ J J U LA L J Z Z U ko SHEET NAME: SHEET NUMBER: R* Ld NOTES v'lv'lnt.Sola-,-----' 1.877.404.4129 CA LICENSE: B/C46/C10/C39-973756 JACOBS RESIDENCE 50485 VERANO DR LA QUINTA, CA, 92253-9011 UTILITY ACCOUNT #: 50688654 SERVICE #: S-6279294 REGNAL OPERATING CENTER: CA•21 E 5.0 DATE: 2.3.2020 QRAWN BY: BRENT PERSCMON NOTES ';►1►1i1iI111jjl vt.cam'��.. g�� a & C & Nfivin#.Solar 1.877.404.4129 CA LICENSE: B/C46/C10/C39-973756 L BS RESIDENCE 485 VERANO DR INTA, CA, 92253-9011 ACCOUNT M 50688654 SERVICE M S-6279294 REGIONAL OPERATING CENTER: CA-21 5.1 I DATE: 2.3.2020 DRAWN BY: BRENT PERSCHON