Loading...
08-0581 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: The Rise Residence The Madison Club La Quinta , CA 02253 Project Designer: Demetriou Architects 5555 Lakeview Drive, Suite 200 Kirkland, WA 98033 (425) 827-1700 - Report Prepared B3 : p P 1/ Michael Faugno BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LAU Q I NTA BUILDING & SAFETY DEPT. APPROVED Job Number: � FOR CONSTRUCTION DATE 0 6D *Y U Ga- SEP Bn 4 ZQpB Dater, 7/14/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number. User Number. 3665 TABLE OF CONTENTS'. Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1R Mandatory Measures Summary 9 Form WS -5R Residential Kitchen Lighting 11 .Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R -The-Rise-Residence n/a ft2 ❑ Multi Family 7_/1412008 Project Title 4,421 ft2 (N) 0 deg Date _T_h e_M a d i s o.n_Cl.0 b -L a_Q u.i n to Natural Gas Fenestration: 2 Project Address Area: 1,738 ft2 Building Permit # CON.DI_T_ION.I.NG 30.6% Avg. (760) 346=0855 BUILDING ZONE INFORMATION _B.REEZE_AI.R Documentation Author Zone Name Telephone plan Check/Date _En:er_g_y_P_r_o Wall_ CA Climate_Zo.n.e 1.5 Field Check/Date Compliance Method 3,6.0.3 _63,5.31 Climate Zone [XI TDV Standard Proposed Compliance Wall_ (kBtu/sf-yr) Design Design Margin Space Heating 2.86 4.38 -1.52 _0.9_A6 Space Cooling 64.74 56.74 8.00 58: _0.069_-R21_R_0_0_ Fans 9.21 9:54 -0.33 [X Domestic Hot Water 4.26 4.75 -0.49 Wall_ Pumps 0.00 0.00 . 0.00 -270__9.0 Totals 81.07 75.41 5.66 0.9=A6 Percent better than Standard: .Roof 7.0% 382_ _0..025_ BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: [X-] Single Family ❑Addition n/a ft2 ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: 4,421 ft2 (N) 0 deg Fuel Type: Number of Dwelling Units: Natural Gas Fenestration: 2 Tilt 'Y / N - Status Area: 1,738 ft2 Avg. U': 0.44 Ratio: 30.6% Avg. SHGC:. 0.42 BUILDING ZONE INFORMATION 0 Zone Name ❑New Floor Area " 'Volume .HVAC=#1_(Sleeping) Wall_ 2,07-1 _20..7.96 .HVAG#2_(Living) -R:21_ _R=0.0_ 3,6.0.3 _63,5.31 Total Conditioned Floor Area: 5,674 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 4,421 ft2 Average Ceiling Height: 14.9 ft Number of Dwelling Units: 1.00 Number of Stories: 2 # of Thermostat Vent Units Zone Type 'Type Hgt. Area -0.36_ Sleeping _SleepingStat- 8 -n/a _0..6_4_ Living _LivingStat_ . 8 -o/a Run Initiation Time: 07/14/08 08:59:39 Run Code: 1216051179 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:3 of 11 Act. Gains Condition OPAQUE SURFACES Insulation Type Frame Area U -Fac. Cay. Cont. Azm. Tilt 'Y / N - Status JA IV Reference Location / Comments _Roof .W.00d- 930_ _0.025_-R=38__R=0.0_-3.45_ 0 ❑New 01 A1.8 ZONE#_1 Wall_ Wood_ _27.5_ _0.0.69_ -R:21_ _R=0.0_ 0_-9.0. [XI ❑ New' . _0.9=A6 ZONE_#_1 Wall_ Wood_ 358_ _0..0.69_.._&21_-R=0..0_-9.0__9.0. �1❑New- _0.9_A6 ZONE_#1 Wall- Wood_ 58: _0.069_-R21_R_0_0_ 1.80.90 [X HNew _09=A6 ZONE#1 Wall_ Wood_ 51. _0..0.69 _R21_R0_0_ -270__9.0 17(I New 0.9=A6 ZONE_#1 .Roof Wood_ 382_ _0..025_ _1838_ _13=0...0_ _3.4.5_ 0 [XI ❑New _01=!_A1.8 ZONE_#3 Wall_ Wood_ 28_ _0.069_-R21__R=0.0_ 0.901 ❑New 09=A6 ZONE_#3 -Wall-Wood-_270- _0.069_-R21__B0_0_ _90_X, 90 [New - ❑New _09 A6 ZONE -#3 Wall_ Wood_ 9_4_ _0...069_-R2 1__B .0_ 0 1.809.0 [X _09=A6 ZONE_#3 Wall_ Wood_ 1.7.6_-0.0.6.9__) 21__&0..0__27.0_-90 DK ❑New _0.9=A6 ZQNE#E3 _Roof Wood_ 720__0.025_-'R38__RO_0__345_ 0 IXINew _01_A1.8 ZO.NE_#4 -Wall-Wood- 1.35_ _0_069_ _R21_ _R=0_0_ 0__90 [XI New 09=A6 ZONE #4 _W_ ..all_ .W..00d_ 20.0_ _0..0.69_ _821_ _R=0..0_ _9.0__9.0 IXI . New _0.9=A6 ZONE_ -4 _W_ ..all_ Wood_ 62_ _0.0.69_ _R21_ _R=0.0_ _1.80._9.0[)(I ❑ New _0.9=A6 ZONE_#- -Wall- Wood- 355_ _0.0.69_ _R:21__80..0_-27.09.0 [X New 09=A6 ZONE_#4 .Roof Wood_ 1.,822_ _0...025_-R38__R=0.0__34.5_ 0 [XI ❑New .01_/__1.8 ZONE_#2 Wall_ Wood_ 532 _0_069_-821__8=0.0_ 0_-90 [XI ❑New .09=A6' ZONE1#2 Wall_ Wood- 99__0_069_-821__R=0..0_-90_ 9.0 �I ❑New 09-A6 ZONE_#2 Wall_ Wood_ 545_ _0..069_ -R:21_ _R=0.0_ 1.81_90 [XI ❑ New _09=A6 ZONE42 _W..all- Wood_ 1;159_ _0.0.69_-R:21__R_0...0_-27.09.0 [XI ❑New . _0.9=A6 - ZONE12 .Roof Wood_ 508_0025_-838__800_-3.45_ 0. [XI ❑New _011A1.8 ZONE_#.5 Wall_Wood_4.4.7- 0.069__R:21_800_ 0__90 [X❑New . _09=A6 ZONE_#5 -Wall-Wood-1.9.5__0069_-R:21__R_0.0__9.0_ 9.0 [X New _09-A6 ZONE -#5 -Wall- Wood- 548__0.069_-821_80.0_ -1.80--9.0 IX I El New 09=A6 ZO.NE_#5 Mall -Wood. -1.86--0.061- RUI_80.0_ -27.0__90 [)Q ❑New _ .09=A6 ZONE -#.5' Run Initiation Time: 07/14/08 08:59:39 Run Code: 1216051179 EnergyPro 4.4 by EnergySoft User Number: 3665 Job Number: Page:3 of 11 Certificate Of Compliance Residential (Part 2 of 4) CF -1 R The Rise Residence 7/14/2008 Project Title Date FENESTRATION SURFACES Insulation . Condition Location/ Type Length R -Val. Location JA IV Reference Status True Cond. Location/ # Type New Area U- Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1_ _Skylight_F_ront_(N)__9.0_ Slab Perimeter 266 _0..7-9.0 11.6=A._0..67 116_6. _34.5_ _0_ NewD.efault-SkylighL(30.30.) -ZONE-#1 2 Skylight Front (N)_ 25.0 0.790 116-A 0_67 116-B 345 0 New Default Skylight (26100) ZONE #1 3 Window Left (E)_ 184.0 0.500 116-A 0_67 116-B 90 90 New Default Glass Block (108) ZONE #1 4 Window Left (E)_ 12.0 0.290 NFRC 0_33 NFRC 90 90 New Eagle Axiom (FxdWdw)_(104b)_ ZONE #1 5 Window Left (E)_ 12.0 0.290 NFRC 0_33 NFRC 90 90 New Eagle Axiom (Fx6Wdw)_(104c)_ ZONE #1 6 WindowRear (S)_ 96.0 0.300 NFRC 0.33 NFRC 180 90 New Eagle Axiom (FxdWdw)_(106) ZONE #1 7 Window Right_(W)_ 48.0 _0:320 NFRC 0:32 NFRC _270_ _90 New Eagle Ascent_(SGD)_(106a) ZONE_#1 8 Window Left (EO 6.0 0.350 NFRC 0_29 NFRC 90 90 New Eagle AxiomCsmt (114) ZONE #3 9 Window Rear($)_ 48 0"0 320NFRC 0 32 NFRC 180 --QCL New Eagle Ascent_(SGD)_(113a) ZONE #3 J-0. Skylight_Eront_(N)_ _2.4_ Q.790 116iA-0-67 116=B _345 0 New Default Skyligbt_(2.4) ZONE -#4 11 Skylight Front (N)_ 2.4 0.790 116-A 0_67 116-B 345 0 New Default Skylight (2_4) ZONE #4 12 Window Front (N)_ 11.3 0.350 NFRC 0.29 NFRC 0 90 New Eagle Axiom (Awning)_(206a) ZONE #4 13 Wlnd.oywEront_(N)_ 41..3 _0,350 NERC -Q.29 NERC 0_90-Ne_w_Eagle_6xio.m_(Awning)-(206.b) ZONE_#_4 14 Window Left (E)_ 21.0 0.350 NFRC 0_25 NFRC 90 90 New Eagle Ascent (Swnga[ _(206a)_ ZONE #4 15 Window Rear ( 96.0 0.330 NFRC 0_31 NFRC 180 90 New Eagle Ascent (SGD)_(204a) ZONE #4 16 Window Right (W)_ 12.5 0.350 NFRC 0_29 NFRC 270 90 New Eagle Axiom (Csmt)_(204) ZONE #4 17 Window Right (W)_ 8.0 0.350 NFRC 0_29 -NFRC. 270 90 New Eagle Axiom (Awning) -(205) ZONE #4 18 Window Right (YJV_ 4.0 0.350 NFRC 0_29 NFRC 270 90 New Eagle Axiom(Awning)_(207) ZONE #4 19 Window Riaht_(IN)_ _30_0 0 350 NFRC 0.29 NFRC 270 90 New Eagle Axiom (Awning) -(005c)- ZONE #4 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 Bug Screen 0.76 _ 4 Bug Screen 0.76 _ 5 Bug Screen 0.76 _ 6 Bug Screen 0.768 0 . 12-0 4.0 0_1 4.0 4.0 7 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 8 Bug Screen 0.76 _ 9 Bug Screen _ _ 0.76 _ 10 None 1.00 11 None 1.00 ' 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 _ 16 Bug Screen 0.76 _ 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 _ THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation . Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 154 None No Insulation 26-A1 New ZONE #1 Slab Perimeter 88 None No Insulation 26 -Al New ZONE #3 Slab Perimeter 266 None No Insulation 26-A1 New ZONE #2 Run Initiation Time: 07/14/08 08:59:39 Run Code: 1216051179 EnergyPro 4.4 by EnergySoft User Number. 3665 Job Number: Page:4 of 11 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Rise Residence 7/14/2008 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat, Glazing Type Comments 20. Window F_ront_(N)_-60..0_ 0.35.0 -NERC--O,.29 _NF_RC 0_ _9.0_ New EagleA_xiom_(.Csmt)_(102) _40NE-#2 21 Window Front (N)_ 69.0 0.770 116-A 0_59 116-B . 0 90 New Default Dbl Mtl Tint(Swnglr_(101 . ZONE #2 22 Window Front (N)_ 24.0 0.770 116-A 0_59 116-B 0 90 New Default Dbl Mtl Tint(SwngDr)_(112). ZONE #2 23 Window Front (N)_ 46.0 0.290 NFRC 0_33 NFRC 0 90 New Eagle Axiom (FxdWdw)_(101a)_ ZONE #2 24 Window Left (E)_ 96.0 0.320 NFRC 0_33 NFRC 90 90 New Eagle Axiom (Awning)_(112c) ZONE #2 25 Window Left (E)_ 12.5 0.350 NFRC 0_29 NFRC 90 90 New Eagle Axiom (Csmt)_(120) ZONE #2 26 Woo ow_Left_(E)- -2!LO- _0 770 116-A 0 59 116=6 90_ _90_ New D_efeult_Dbl Mtl Tint(SwngDr)_(120)._ZONE #2 27 Window Rear 112.0 0.330 NFRC 0_31 NFRC 180 90 New Eagle Ascent S( GJ_(1 03) ZONE #2 28 Window Rear {S)_ _211.5 0.770 116-A 0_59 116-B 180 90 New Default Dbl Mtl Tint(SGD)_(104)_ ZONE #2 29 Window_Rear (S)_ 94 _Q 0:300 BFRC -Q$3 NFRC 180_ 00_ New Eagle Axiom-(ExdWdw)-(104a)_ ZONE#2 30 Window Right {W)_ 27.0 0.350 NFRC 0.29 NFRC 270 90 New Eagle Axiom (Csmt)_(103) ZONE #2 31 Window Right(W)_ 13.5 0.350 NFRC 0_29 NFRC 270 90 New Eagle Axiom (Csmt)(122) ZONE #2 32 Window Right_(W_)- 18..Q _03.50_N_ F_RC _0..29 -NERC. _270_ _90. New Eagle_Axiom_(.Csmt)-(124.) ZONE_#2 33 Window Right (W)_ 48.0 0.320 NFRC 0_33 NFRC 270 90 New Eagle Axiom (Awning)_(112b) ZONE #2 . 34 Window Right (W) 48.0 0.320 NFRC 0_33 NFRC, 270 90 New Eagle Axiom (Awning)_(1 12a) ZONE #2 35 Skylight Front (N)_ 20.3 0.790 116-A 0_67 116-B 345 0 New Default Skylight (4646) ZONE #5 36 Window Front (N)_ 70.0 0.330 NFRC0_31 -NFRC. 0 90 New Eagle Ascent (5GD)_(202) ZONE #5 37 Window Front (N) 21.0 0.290 NFRC 0_33 NFRC 0 90 New Eagle Axiom (FxdWd__J_(101b) _ZONE #5 38 Window Front_(N)_ 16_0 0 290 NFRC 0 33 NFRC 0 90 New Eagle Axiom (FxcL- w)_(101c)_ ZONE#5 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 6.0 10.0 3.0 0:1 3.0 3.0 21 Bug Screen 0.76 11.6 6.0 10.0, 0.1 10.0 10.0 22 Bug Screen 0.76 23 Bug Screen 0.76 11.6 4.0 10_0 -Al _10 0 -!A-O 24 Bug Screen 0.76 _ 25 Bug Screen 0.76 -5_0 2.6 2.00 1 - 2.0 2.0 26 Bug Screen 0.76 27 Bug Screen 0.76 8.0 14.6 100 0.1 10.0 10.0 _ 28 Bug Screen 0.76 9.0 23.6 10.0 0.1 10.0 10.0 29 Bug Screen 0.76 4.0 23.6 10.0 0.11 10.0 10-.0 _ 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76' 33 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 10.0 _ 34 Bug Screen 0.76 8.0 6.0 10.0 0.1 10.0 .10.0 35 None 1.00 _ 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 07/14/08 08:59:39 Run Code: 1216051179 EnergyPro 4.4 by EnergySoft User Number. 3665 'Job Number:: Page:5 of 11 6,.,1J'fr4'' Certificate Of Corn liance • Residential "' Part 2 of 4 `CF -1 R The Rise Residence'` - 7/14/2008 Project Title - Date - FENESTRATION SURFACES' - True Cond.. `• Location/ # Type Area U -Factor' SHGC2. Azm.. Tilt Stat' Glazing Type Comments ' -39. Window_Eront_(N.)_ _1.6.0- __0.29.0.NF_RC-_0.33 _NF_RC.` 0_ •_9.0_ New—EagleAxiom-(F—xd.W-.dw)_(J.01.d.)_ZONE_#5 40 Window Left (E)_ 12.0' 0.300 NFRC 0_33 NFRC 90 90 New - Eagle Axiom (FxdWdw)_(101g)=. ZONE #5 ' 41 Window Left (E)_ 12:0`'-.0:290 NFRC 0_33. NFRC 90 90 New Eagle Axiom (FxdWdw)_(101f)_ ZONE'#5 42 Window Left (E)_ 12.0--- 0.290 NFRC 0_33 NFRC 90 90 New Eagle Axiom (FxdWdw_(101e)_ ZONE #5 43 Window Rear (S_ 16.0^ 0.350 NFRC 0_29 NFRC " 180 90 New • 'Eagle Axiom (Csmt)_(101h) ZONE #5 1. indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. ' INTERIOR AND EXTERIOR SHADING Window Overhang ' Left Fin Right Fin # Exterior Shade Type 'SHGC Hgt. Wd. Len. Hgt. I -Ext. 'RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 , Bug Screen 0.76 f 40 Bug Screen 0.76- 41 Bug Screen 0.76 42 . Bug Screen 0.76 43 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat. . " Inside ' Condition Location/ Type (so (in.)' Cap. Cond. R -Val. JA IV Reference,', ' Status. ' Comments, - PERIMETER LOSSES Insulation . • . ` ,'SCondition Location/ Type Length ` R -Val.* . • Location , JA IV Reference ': - Status' Comments Certificate Of Compliance:' Residential (Part 3 of 4) CF -'I R The Rise Residence 7/14/2008 Project"Title Date HVAC; SYSTEMS t Insul. System Name Length Diameter Thick. ' Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#1 (Sleeping) Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC -#2 (Living) Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Multi -Family Central Water Heating Details ( Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC-#1.(Sleeping) Ducted Ducted Attic 4.2 New Yes HV C42 (Living) Ducted Ducted Attic 4.2 New Yes Hydropic Piping Pipe Pipe Insul. System Name Length Diameter Thick. ' WATER HEATING SYSTEMS' Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst(Btu/hr (gal) Status or RE Loss (%) Ext. Standard Gas 50 gal. Small Gas, No Pipe Insulation 1 40,000 50 New 0.53 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length'(_ Add 1/2" Control #' HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs,'insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved -HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Michael Faugno Title/Firm: Demetriou Architects Title/Firm: BREEZE AIR CONDITIONING Address: 5555 Lakeview Drive, Suite 200 Address: 75-145 ST. CHARLES PLACE Kirkland WA 98033. PALM DESERT, CA 92211' Telephone: _(425) 827-1700 Lic. #: Telephone: _(7.346-0855 (signature) . (date) (signature) (date) Enforcement Agency Name: Title/Firm: Address: — Telephone: (signature) (date) Certificate Of Compliance :*Residential (Part 4 of 4) .. CF -1 R The Rise Residence 7/14/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with. the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies ,aseu on the auequacy or the special /usaricauon ana aocumentation suomittea. Plan Field The Roof "R-38 Roof' includes credit for a Radiant Barrier installed per Section. 3.3.3 of the Residential Manual. The HVAC System "HVAC -#1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -#2 (Living)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HERS Required Verification Items in this section require field testing and/or verification by certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC -#1 (Sleeping)" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -#1 (Sleeping)" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic . Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (5 Ton) -13 SEER" includes credit for a 11.6 EER Condenser. A certified HERS rater must r field verify the installation of the correct 'Condenser. , The HVAC System "HVAC -#2 (Living)" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC -#2 (Living)" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "PSA2BD / PGC1 RA (5 Ton) 13 SEER" includes credit for a 11.6 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. Mandatory Measures Summary:. -Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these' measure's regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether . they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the . ENFORCE - permit application documentation. NIA DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑" ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑ ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ . § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. closable metal or glass door covering the entire opening of.the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ , ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑" El ❑ " CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X _ ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ J Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACOA. ❑ ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑ §'1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑. ❑X ❑ . having an installed thermal resistance of R-12 or greater. - 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ n ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ' ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems, or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due "to sunlight, moisture, equipment maintenance, ❑ 0 ❑ and wind. 6. Insulation for'chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft. User Number. 3665 Job Number: Page'9 of 11 .I Mandatory Measures Summary: Residential (Page 2 of 2) MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -1 applicable. N/A DESIGNER MENT ,Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool healers, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that dies not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. ❑ O ❑ LJ LFX1 ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ IJ ❑ ❑ ❑ ❑ ❑ a ❑ ❑ 0 ❑ § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. f�1 § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more _1 dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). 4.4 .by EnergySoft User Number: 3665 Job Number: 0 0 I ❑X ❑ ❑ ❑ ❑ Page: 10 of 11 Residential Kitchen Lighting Worksheet WS-5R The Rise Residence 7/14/2008 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Watts Quantity Watts Other Watts (1) 2 ft Fluorescent T8 Elec Yes n No (_ I 22.0 x 2 ._ 44 or (1)4 ft Fluorescent T.8 Elec Yes XI No I 37.0 x 6 222 or (2) 26w Compact Fluorescent Triple 4 Pin Yes XI No 74.0 x 2 _ 148 or 32w Compact Fluorescent Triple 4 Pin Yes XI No 32.0 x 14 = 448 or 3w Low Voltage Cove Lighting Yes I No LX 3.0 x 75 - or 225 50w Low Voltage Halogen Yes I No I XI 50.0x 7 _ or 350 60w Penadant Incandescent Yes I No IXI 60.0 x 3 = or -180 Yes I No x - or Yes I No x = or Yes No x - or Yes No x Yes No x = or Yes No I x = or Yes I No x = or Yes No x = or Yes I No x = or Yes No z _ or Yes No x = or Yes I No x = or. Yes 7 No x = or Total A: 862 B: 755