BMCH2018-0300Permit Details
PERMIT NUMBER
City of La Quinta BMCH2O18-0300
Adi
Description: INSTALL DAIKIN 1 TON MINI SPLIT SYSTEM
Type: MECHANICAL (WEB) Subtype: Status: ISSUED
Applied: 7/24/2018 ECON
Approved: 8/7/2018 AMA
Issued: 8/7/2018 AMA
Finaled:
Expired: 2/3/2019 AMA
Parcel No: 770092011 Site Address: 78680 AVENIDA TUJUNGA LA QUINTA,CA 92253
Subdivision: DESERT CLUB TR UNIT 5 Block: Lot: 23
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $3,700.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: INSTALL NEW DUCTLESS MINI -SPLIT SYTEM(19SEER/90AFUE/12,000BTU) IN AN EXISITING 2 CAR GARAGE. THIS UNIT IS MEANT TO
COOL DOWN GARAGE ONLY. GARAGE IS NOT TO BE USED AS HABITABLE SPACE.THIS PERMIT ONLY INCLUDES ELECTRICAL PORTION,
OWNER DECLINED TO PERFORM ENERGY UPGRADES TO THE UNCONDITIONED SPACE. PER 2016 CALIFORNIA ELECTRICAL CODE.
ro - ummary
114
Applied to Approved
Approved to Issued
ADDITIONAL SITES t
■;•L• •
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
PUBLIC COUNTER VISIT
ARMANDO MAGALLON
8/1/2018
8/1/2018
I SPOKE TO APPLICANT AND RECEIVED THE LETTER FROM
OWNER THAT HE WASNT GOING TO COVERT THE GARAGE
SPACE TO LIVABLE SPACE. I LET APPLICANT KNOW HE
NEEDED TO REVISE CF1R TO SHOW A NEW SYSTEM WAS
BEING INSTALLED AS WELL AS A SITE PLAN SHOWING THE
LOCATION OF NEW UNIT.
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
FIRST CHOICE A / C & HEATING INC
79-747 CASSIA STREET
LA QUINTA
CA
92253
(760)989-2369
lstchoicecooling@gma
il.com
CONTRACTOR
FIRST CHOICE A / C & HEATING INC
79-747 CASSIA STREET
LA QUINTA
CA
92253
(760)989-2369
lstchoicecooling@gma
il.com
Printed: Wednesday, June 28, 2023 10:52:09 AM
1 of 3
CRWSYSTE S
Permit Details PERMIT NUMBER
City of La Quints BMCH2O18-0300
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY I STATE I ZIP I PHONE I FAX I M. EMAIL
OWNER
BRIAN DEVLIN
78680 AVENIDA
TUJUNGA
LA QUINTA
CA
92253
(
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $1.00 $1.00
Credit Card Fee
101-0000-43505
0
$2.39
$2.39
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
Total Paid for Credit Card Fee: $2.39 $2.39
APPLIANCE
REPAIR/ALTERATION
101-0000-42402
0
$13.00
$13.00
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
APPLIANCE
REPAIR/ALTERATION PC
101-0000-42600
0
$5.20
$5.20
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
Total Paid for MECHANICAL: $18.20 $18.20
PERMIT ISSUANCE
101-0000-42404
0
$98.83
$98.83
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
Total Paid for PERMIT ISSUANCE: $98.83 $98.83
RECORDS
MANAGEMENT FEE
101-0000-42416
0
$10.00
$10.00
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
0
$5.00
$5.00
8/7/18
R38338
08878D
CREDIT
CARD
ATILA BOTH
AMA
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS: $135.42 $135.42
Printed: Wednesday, June 28, 2023 10:52:09 AM
2 of 3
CRWSYSTEMS
Permit Details
City of La Quinta
INSPECTIONS
PARENT PROJECTS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED
DATE
STATUS
REMARKS
NOTES
1ST BLDG NS JULIO ANAYA 7/24/2018 7/25/2018
ETRAKIT (1 DAY)
8/2/2018
APPROVED -
CONDITIONS
PROVIDE SITE PLAN ILLUSTRATING NEW
PROPOSED MINI SPLIT CONDENSER. UNIT MUST
BE LOCATED IN AN APPROVED LOCATION EITHER
AT REAR YARD SETBACKS OR SIDE PROPERTY
LINE.
SITE PLAN SUBMITTED
1ST PERMIT TECH (1
DAY)
ARMANDO
MAGALLON
8/7/2018
8/8/2018
8/7/2018
APPROVED
APPLICANT STOPPED BY OFFICE AND SUBMITTED
SITE PLAN.I SPOKE TO CARLOS AND SINCE MINI
SPLIT WILL BE LOCATED AT REAR THERE IS NO
MINIMUM SETBACK.
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
8/1/2018
ARMANDO MAGALLON
1ST SUBMITTAL - SPACE
CONDITIONING
RESTRICTION IN
GARAGE.pdf
1ST SUBMITTAL - SPACE
CONDITIONING
RESTRICTION IN
GARAGE.pdf
0
DOC
8/7/2018
ARMANDO MAGALLON
1ST SUBMITTAL SITE
PLAN
3053 001.pdf
—
0
DOC
7/27/2018
EtrakitContractor
1ST SUBMITTAL - CF1R
ms calcerts.pdf
1
Printed: Wednesday, June 28, 2023 10:52:09 AM
3 of 3
CRWSYSTE S
114 i(‘) HoUSG
l
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED .FOR
CODE
COM PUANCE
DATE f3I7 (I..By. (4114)
S+ 4f c 8.0 3 00
Brian Devlin
78680 Avenida Tujunga
La Quinta, CA. 92253
(760) 766-5448
To Whom It May Concern:
RECEIVED
AUG 01 2018
CITY OF LA QUINTA
COMMUNITY DEVELOPMENT
I, Brian Devlin, will be adding an ac unit to my garage and not using it as a
habitable space but solely for cooling purposes.
Thank you,
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 1 of 3)
Project Name:
mini split devlin
Date Prepared:
2018-07-27
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
mini split devlin
02
Date Prepared
2018-07-27
03
Project Location
78680 avenida tujunga
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
mini split devlin
07
Zip Code
92253
08
Dwelling Unit Conditioned
Floor Area (ftZ)
400
09
Climate Zone
15
10
Number of Space
Conditioning (SC) Systems in
this Dwelling Unit:
1
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System (ft2)
Is the SC
system a
ducted
system?
Installing a
refrigerant
containing
component?
Installing new SC
system
components?
Installing
more than 40
feet of ducts?
Installing
entirely new
duct system?
Installing
entirely new
SC system?
Alteration Type
System 1
Location 1
400
No
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 218-A020216131A-000-000-0000000-0000
Registration Date/Time: 2018-07-27 13:43:45
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006
Schema Version: rev 10/16
Report Generated: 2018-07-27 13:43:39
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
System
Identification
or Name
Heating
System
Type
Altered
Heating
Components
Heating
Efficiency
Type
Heating
Minimum
Efficiency
Value
Cooling
System Type
Altered
Cooling
Components
Cooling
Efficiency
Type
Cooling
Minimum
Efficiency
Value
Required
Thermostat
Type
New or
Replaced
Duct Length
New Duct
R-Value
System 1
Ductless
mini split HP
All new
heating
components
HSPF
8.5
Ductless
mini split HP
All new
cooling
components
SEER
19
Setback
This field or
section is not
applicable
This field or
section is not
applicable
Required Documentation:
Systems
new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
<= 10% leakage to outside, or seal all accessible leaks.
Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
>= 300 CFM per ton required when MCH-25 is required.
provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
CF2R-MCH-01-E - Space
- Duct insulation requirement
CF2R and CF3R-MCH-20-H
-Leakage rate compliance:
CF2R and CF3R-MCH-25-H
CF2R and CF3R-MCH-23
Exceptions:
Conditioning
for the
- Duct Leakage
<= 15% or
Refrigerant
Airflow Rate
with HERS
and Air Handler
constructed, insulated
- Duct systems registered
- Heating -only systems
-Existing duct systems
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 218-A020216131A-000-000-0000000-0000
Registration Date/Time: 2018-07-27 13:43:45
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2016.1.006 Report Generated: 2018-07-27 13:43:39
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 3 of 3)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Both, Atila
Documentation Author Signature:
LAti� .Bot
Company:
FIRST CHOICE A / C & HEATING INC
Signature Date:
2018-07-27 13:43:45
Address:
79-747 CASSIA STREET
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
LA QUINTA CA 92253
Phone:
760-989-2369
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Both, Atila
Responsible Designer Signature: /�
v�tt/a .13od
Company :
FIRST CHOICE A / C & HEATING INC
Date Signed:
2018-07-27 13:43:45
Address:
79-747 CASSIA STREET
License:
968138
City/State/Zip:
LA QUINTA CA 92253
Phone:
760-989-2369
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
Easy to Verify 0 .• f , 0
at CaICERTS.com 6 t
z
. •ti
Registration Number: 218-A020216131A-000-000-0000000-0000
Registration Date/Time: 2018-07-27 13:43:45
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2016.1.006
Schema Version: rev 10/16
Report Generated: 2018-07-27 13:43:39