11-0328 (ELEC) wily". 44aotriJ P.O. BOX 1504 ^' VOICE(760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING&SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/01/11 Application Number: 11-00000328 Owner: Property Address: 57833 CHERRYWOOD PL STANDARD PACIFIC COACHELLA VLY APN: 762-240-042-C -33336 - 15326 ALTON PKWY Application description: ELECTRICAL IRVINE, CA 92618 Property Zoning: LOW DENSITY RESIDENTIAL (949)789-1600 Application valuation: 2500 1� 1 D.... Lt 1� Contractor: Applicant: Architect or Engineer: STANDARD PACIFIC CORP APR 01 2011 .J 26 TECHNOLOGY .5 1,1l IRVINE, CA 92618 I /0/ (949)789-1600 CITY OFLAQUINTA- - Lic. No. : 6416651l�AGE DEFT • LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9(commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000)of Division 3 of the Business and Professionals Code,and my License is in full force and effect. _ I have and will maintain a certificate of consent to self-insure for workers'compensation,as provided License Class: $ License No.: 641665 for by Section 3700 of the Labor Code,for the performance of the work for which this permit is :feissued. ate: �'F pt f nu actor: �" „� I have and will maintain workers'compensation insurance,as required by Section 3700 of the Labor �d Code,for the performance of the work for which this permit is issued. My workers'compensation OWNER-BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier NATL UNION FIRE Policy Number WC20635371 following reason(Sec.7031.5,Business and Professions Code: Any city or county that requires a permit to _ I certify that,in the performance of the work for which this permit is issued,I shall not employ any construct,alter,improve,demolish,or repair any structure,prior to its issuance,also requires the applicant for the person in any manner so as to become subject to the workers'compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that,if I should become subject to the workers'compensation provisions of Section License Law(Chapter 9(commencing with Section 7000)of Division 3 of the Business and Professions Code)or 3700 of the Labor Code,I she forthw. comply with those isions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars(5500).: 0 _I—1 f/! pplicant: ( 1 I,as owner of the property,or my employees with wages as their sole compensation,will do the work,and the structure is not intended or offered for sale(Sec.7044,Business and Professions Code: The WARNING: F LURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL,AND SHALL Contractors'State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees,provided that the DOLLARS(5100,000). IN ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If,however,the building or improvement is sold within I SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEY'S FEES. one year of completion,the owner-builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT 1 ) I,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec. I IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044,Business and Professions Code: The Contractors'State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon,and who contracts for the projects with a contractor(s)licensed 1. Each person upon whose behalf this application is made,each person at whose request and for pursuant to the Contractors'State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, 1_I I am exempt under Sec. ,B.&P.C.for this reason I the owner,and the applicant,each agrees to,and shall defend,indemnify and hold harmless the City of La Quinta,its officers,agents and employees for any act or omission related to the work being performed under or following issuance of this permit. Date: Owner: 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,or cessation of work for 180 days will subject CONSTRUCTION LENDING AGENCY permit to cancellation. I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the I certify that I have read this application and state that the above information is correct. I agree to comply with all work for which this permit is issued(Sec.3097,Civ.C.). city and county ordinances and state laws relating to building construction,and hereby authorize representatives of ell County to enter upon the above-mentioned property for Lender's Name: r sate: ��-4{ Si lure(Applicant or Agent): Lender's Address: LQPERMIT Application Number 11-00000328 Permit ELEC-SERVICE CHANGE INV FEE Additional desc . Permit Fee . . . 67.00 Plan Check Fee . -00 Issue Date . . . Valuation . . 0 Expiration Date 9/28/11 Qty Unit Charge Per Extension BASE FEE 30.00 1.00 37.0000 EA ELEC SVC <=600V/<=200A 37.00 Special Notes and Comments INSTALL 100 AMP TEMPORARY METER PEDESTAL FOR COMMON AREA LIGHTING & IRRIGATION CONTROLLER. INCLUDE 350 L.D. UNDERGROUND CONDUIT FROM EXISTING PEDESTAL @ 57-810 ROSEWOOD COURT TO TEMP PEDESTAL. INVESTIGATION FEE ASSESSED PER 1997 UNIFORM ADMINISTRATIVE CODE §304.5 FOR WORK BEGUN WITHOUT BUILDING PERMIT.2010 CODES. Other Fees BLDG STDS ADMIN (SB1473) 1.00 Fee summary Charged Paid Credited Due Permit Fee Total 67.00 .00 .00 67.00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1.00 .00 .00 1.00 Grand Total 68.00 .00 .00 68.00 LQPERMIT POWER QUOTE: 399625 DS PLu S' 3/30/2011 8:27:57 AM eb TS PPArea: DS PALM SPRINGS, CA 92240 (760)288-2775 FAX (951)657-0441 Customer: Standard Pacific-Coachella Valley Job: Palo Verde -Tr#32279 & 33336 Job#: 251585 26 Technology Drive Ord Supr: Gary Sampson Supr Cell: (949) 933-7589 Irvine, Ca 92618 Supr Phone: (949) 933-7589 (949)789-1600 Fax: (714)641-5572 Tract#: - Phase: U/G Installation to Irrigation Ped. Location: 57-865 RoseW:Gt Contract#: P 0#: Cross Str: 58th x Madison, La Quinta Phone: (760)564-6200 Fax: (760)564-2269 Remarks: Monthly*rental charges will be$0.00 per month*after the first 0 months*. *Months will be calculated in 28-day periods. Quantity Equipment/Service 375 UG Cable -1/0 AL 4 Wire#6 CU (1 Foot) 350 Conduit -2" PVC SCH 80 (1 Foot) 1 Trencher 8 Labor Hour Total: $2,631.69 Quote Notes: Note:After the meter is set and inspected,please allow 7 to 10 working days for the utility company to energize your meter Please figure on more days during and immediately after periods of RAIN,HIGH WINDS,and excessively HOT DAYS 'Power Plus!is not responsible for the accuracy of information provided by the utility company in relation to the source verification "Permit application fees to be determined by respective City and Utility Standard Pacific-Coachella Valley will provide Power Plus/wish exact equipment locations prior to installation An additional service fee will be charged for any equipment relocation.An additional fuel surcharge has been added due to temporary excessive fuel prices Standard Pacific-Coachella Valley will be responsible for locating and marking all private underground utilities including landscape irrigation systems not identified by USA Dig Alert Standard Pacific-Coachella Valley will be financially responsible for any damage and repair work for any underground private utility systems(including landscape Irrigation systems)not marked prior to equipment Installation.Standard Pacific- Coachella Valley will pay any additional cost far adverse digging conditions,special equipment required for safe installation,additional permits,permit deposits or any other unircual rust nr fee remiirari to nerfnrm instellatinnc cnrvirpc Prior to equipment delivery,a signature by an authorized representative of Standard Pacific-Coachella Valley is required on this Quote Form.Furthermore,if Standard Pacific- Coachella Valley requires a Purchase Order(P.O.),a P.O.#and document must be issued to Power Plus!before work is completed.Rental period is based on 4 week months. Invoices are due upon receipt QUOTE SUBJECT TO SOURCE VERIFICATION PER ELECTRICAL AND/OR TELEPHONE UTILITY COMPANY(S). Standard Pacific-Coachella Valley Signature: Date: Print Name: PowerPlus! Representative: Date: 3/30/2011 Chano Hernandez C1V of U1 C L) IINTA BUILDING &SAFETYAPP DEPT. OV FOR CONST Customer Initial Here: Page 1 of 5 k11- 73'LV IN THE CITY OF LA QUINTA, CO(INTY OF MI€RSIOE; STATE OF CAUFORNIA N TRACT NO. MAP 33336 Q7APMIC SCALE vu0 .L'1j CC AV1A2Et5b. 8o-40a AvrAuf 58 Ui pj. ii.k AN: 9b.-2410- o t% TRACI' Veer Na 2809 ;7-5b 3 rr.®.754/99/04 F3 — 7 m 57-505 it �I 57-5to — — , 1 1 � , (i , I. 5'(-535 'ti' i 57.540 - - if 1 i 1 " ff i 1 + 3 51.5(v5 1 I 57-570 N. E! -h � I i 4 h � ST-boe 57.5ct5 I r 57-boo 1 q n 15 1 57-(P25 I I57-630 I— — 1° 5�1-:55 I \ 57-660 1...- - - 1. - .,ter rl t 4y i # ! .� 51-a5 , r 57.vio ••-•- I I Q"$v 51-Too I ._- �- '�riiry Iii]l+'ry IT P. W[` a] 21 9 174 I Ir— 1 h5'1- ' 157-' r— — r I � � 22 A ' 57-7'1S i 57-j80 o I c� v' �T'Eoo '�' 57'So5 �57-810 tia — _Y — —�rnaw°wA`A�rAi, //� 57.840 . I I� I , 57-s77- f �— — — — ---- — r oboe PIA ` ..- ST-9io (HERR:4w0o1" — — y — — J- I PRAcc 57•900 koz,-/ So-beo J. i Avii4o5 5i� M 1_ — -- — �J I 762 Z4o-o43 hi ,-_____-r ( / 57'052 I Q a cm AC z zaC07 r —� — --- — - — sg.000 AVCrillE 58 0 w4 Isi o a s�i7-3f0 �' �aL.�I�.a�y 1•AL 57-833 ! <,_C9...RE t20/2AOV„mod. 3W.-DOA.ML4 120/2 0V.P1-1.3W. FUTURE UTIJTY 42;000 A.lC. COMECTION t.�t�ea�LIB __ - _,� —. le I ! .i„,,,. Pi-aroma. CJNTACTOP ii S.-- � 7 C.D. I 3 m1/O T I-NrfhNVN-AL , /1 ,� L. I u6 AL GND-2'PVC tOOA-2P j� TD UG T 3 ,0, ... I TYPE USE CABLE =375FT. (T1) LL._. . SJ _.....__- .__�. __._i EA I.3% ii p .� _._-' to 8 CU-3/4'TO DRIVEN O ROD - - 5/8'MAX t2FT.>r CONNECT TO RE-BAR __.r• •��. -. ter—. .-----• ------1 \/ ''''.,..'"-- EXISTING EOUPMENT NSTALLED PER THIS PLAN EXISTING EQUIPMENT Existing Single Line Diagram NTS CIRCUIT SCHEDULE EXISTING PANEL gag VOLTAGE g 120/240 TYPE . ELEC. SERVICE PEDESTAL PHASE . IP.,3M BUSSING. IOOA. MOUNTING . FREESTANDIN6 NEMA-3R MAIN , 100A-2P A.I.G . 10 KAIC. CKT. AMPS / LINE AMPS / LINE CKT. No. EQUIPMENT BRKR BRKR EQUIPMENT No. AMPS LI L2 LI 1 L2 AMPS 1 EXISTING LT6. •" 20 6 1 r 20 CONTROL MIRE •" "" 2 3 EXISTING LT6. •■ 20 6 8 20 EXISTING GATE MOTOR •• 4 5 1 CIRCUIT "A" • 20 I 8 20 EXISTING GATE MOTOR •• 6 1 240V. 120 1 8 20 EXISTING GATE MOTOR •• 8 9 CIRCUIT "B" • 20 2 8 20 EXISTING GATE MOTOR •• 10 III 240V. 120 2 3 20 EXIST. IRRI6. CONTRLR ••" 12 13 O 0 14 15 0 0 16 SUBTOTAL 8 8 I-I 19 TOTAL 25 27 6.3 KVA +25% 6.3 KV ( L.C.L ) MIN. FEEDER 33 AMPS 8 KVA TOTAL FEEDER SIZE PROF 21.S/0/v1 I ;STY �� ` ��! 1A �.�¢ AM oN0� LIGHTING DESIGNERS r}1N[� 5 ��Y DEPT. tJ L� ! Z ELECTRICAL ENGINEERS ppBOVED NO.IX 145 m LIM 2 15 STUDEBAKERcoN i-RucTtc EXP. 12-31-11 IRVINE, CA 770— FF.,: .+ 2618 TE L: (949) 770-0909 ;7 fa �0 ii .P'f � t{`(E� `Cps INCORPORATED FAX: (949) 770-0910 ��� �TEofi p��F°.. PROJECT NAME' PALO VERDE DATE: 3/31/II PROJECT NUMBER' 28039 SHEET' I OF 2 SCALE! NTS NOTE' i • CHERRY We OD PL. .. IL '4.67 I kJ R+ N. r-: ;:tifilik Ek7STg 1G ELEC SERVICE PEDESiYAL e O-) r % rr:e : PR 3W rnT "'I► s�' if� MAW Q Or Avi, ,.,_'t,,Illnirillillift...PAVIIMI V* j''' :11111 1 a .......----E E E E E E-COMM4141171*7 fa . 10%1 IIIIIIII.4111115.--41..Ak 3 Ul/O T14-N/THWf-AL I+=6 AL-GND-2'PVC TYPE USE CABLE =375FT. 711 19 �-IX El ��- 1$ 1 (,_,,,. ________,___ __ ,.. ,--,A �-{� �iu�L+ - :�E D -0 U Fi. -i-r 1,�, r, r �' !.p. c o 20 W -1 1 - sa EXISTING TEMPORARY SERVICE PEDESTAL E 3ia57-810I12O/240V.PH,3W. (0,1;76 ��+� ' r'�LIGHTING DESIGNERS - / '' ELECTRICAL ENGINEERS II " lit '�".. 1 ' Z x LDB 15 STUDEBAKER DETAIL A EXP. 12 31-11 IRVINE, CA 92618 SCALE: 1'=30-0' TE L: (949) 770-0909 S� 4'4EC C� \Q' INCORPORATED FAX: (949) 770-0910 Ni nun -11 cA1Lg0 PROJECT NAME: PALO VERDE DATE: 3/31/II PROJECT NUMBER: 28039 SHEET: 2 OF 2 SCALE: I"=30'-0" NOTE' 1 77: 30 13 1 1 1- c\i, 2.1 I 1 2 29 14 2 1 1 3 28 15 3 1 I &_ I 1 4 27 16 i 4 1 8 } 8 -II 1 5 26 17 5 I 1 8T 6 8S gg 25 18 / m 6 g Io ' c 7 24 19 I- I ( 7 _ r 1_I 1 l 8 I I 23 20 8 I f "� al \\\\ 9 e al 22 21 9 10 8_ 21 22 1 10 I. iiiii 1 I 11 PO 23 11 12 o p.... 1 79 hi' 12 I cxi . It � • � Y (//"/" i / I �' 13 18 ` 1 4 Gam, 14 li 17 g— r. 7.....,r� .+�w 4,___, ti �� ay1 \i II i8 I ,',4,• O 4 J} F 15 { f :..\ "� �"1 ly 8 •' :I a 1 'f•r Z. 1 �; fro 1 t. l f� a,°1.-c,; � li( \1 -• ,,, / ' st -Z. '52k7 1. 1f ei. , . ,..___________________— 4 AVENUE 58 111 sas,rs I. { c M. E. Ndlkarnper, Inc. R f a� Temp Power Burial .-- F e ✓ i. -. e STANDARD PACIFIC HOMES «� P Deft Consulting i Design Services P Site Overview R 940 manor WayR Technology Urlve Tracts 32279 3 33336 n12/3,�„ `1-• �� 0 1 i Corona,CaliforniaFax992882 Irvine, 89 82619 PeIO Verde Estates" F•r.,ar _ e 1 951.808.4645 Fax 951.737.9343 R 949.789.1600 La�Winta,California niMamenor.can .a of 2 7 R�'w �� t_ i 1 Existing q 1 X 1 i; Meter Pedestal 2" Conduit 0 i , • V) — r M ' A 1 i 1 * Existing 0 Meter Pedestal 0 # 57-810 CITY OF LA QUIN 9 :\ BUILDING & SAFETY DEPT. 0 ' l'IPPROVED FOR CONSTRUCTION r'' Vy'c') �I 9 torrfiN /: ' 0 i 1 ,, V° . 0 I CATE BY = � ! 2\/ I Existing ._ Meter Pedestal -/ 4 4Joie # 57-833 ,- C) :- / , ./ , \ 1 / o ,,,/ , 1 8 1 li ,, / , ,,,, /\\ \ 1 I ra ` A N S i \ \ I/ rrN i M. E. Nollkam Inc. a • STANDARD PACIFIC HOMES , 66 " '�' Utility Consulting 6 Design Services Temp Power BuriaCVM l a� Conduit Path i ''"+ igie„ 940 Manor Way r 26 Technology Drive Tracts 32279&33336 Yrt03f"f201 . 0 1„ Corona,CaNfor a 92882 o Irvine,CA 92618 "Palo Verde Estates" :.. `� e 951.808.4645 Fax 951.737.9343 949.789.1600 i `Y — mItt menoI.com La Quints,California {2 of 2 Bin# City of La Quinta Building 8r Safety Division Permit# P.O. Box 1504, 78-495 Calle Tampico , nJ La Quinta,CA 92253- (760) 777-7012 I I-O ° _ Building Permit Application and Tracking Sheet Project Address; 57-833 Cherrywood Ct . Owner's Name: Standard Pacific Corp A.P.Number: Address: 26 Technology Drive Legal Description: Lot C of Tract 33336 City,ST,Zip: Irvine, CA 92618 Standard Pacific Corp. Contractor: p• Telephone: 9 4 9/7 8 9-16 0 0 � Address: 26 Technology Drive Project Description: Installation of a, 1ectric City,ST,Zip: Irvine, CA 92618 meter pedestal for common area lighting Telephone: 949/789-1600 _w •``` <> and irrigation controller. State Lic.#: 641665 City Lic.#; - f i `. — #i IV% Arch.,Engr.,Designer: LDB, Inc . ti7�1 15 Studebaker � �� s�B�D Address: �d0Gp �ta� -1-.o "r1'. t-.7 �. J -6. . City,ST,Zip: Irvine, CA 92618 �-"' '�` Telephone: 9 4 9/7 7 0-0 9 0 9 ;A `,' : Construction Type: N/A Occupancy: N/A State Lic.#: EE 11453 Project a circle on ,.. .. ....... - , ) type( e). New Add'n Alter Repair Demo Name of Contact Person: Steve Carren Sq.Ft.: N/A #Stories: N/A #Units: 1 Telephone#of Contact Person: 9 4 9/2 8 3-6161 Estimated Value of Project: $2 , 500 APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES I Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed,ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan , Plans resubmitted Mechanical Grading plan 2".Review,ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A.Approval Plans resubmitted Grading IN HOUSE:- '"Review,ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A•I,P•P. Pub.Wks.Appr Date of permit issue School Fees Total Permit Fees