Loading...
BPOL2022-0182Permit Details City of La Quinta Description: BEAZER / POOL AT REAR YARD. Type: POOL CONSTRUCTION Subtype: PRIVATE Status: ISSUED (WEB) Applied: 4/29/2022 ECON Approved: 5/16/2022 JAN Issued: 5/17/2022 AHI Finaled: Expired: 5/17/2023 AHI Parcel No: 766140020 Site Address: 58181 CORAL VIEW WAY LA QUINTA,CA 92253 Subdivision: TR 31249 Block: Lot: 45 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $10,000.00 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: BEAZER / POOL AT REAR YARD. TWO DROWNING SAFETY FEATURES AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. PLEASE PROVIDE WET STAMPED POOL ENGINEERING SHEET ON SITE FOR INSPECTION FIELD VERIFY. NEW EQUIPMENT MUST BE LOCATED IN AN APPROVED LOCATION EITHER WITHIN THE REAR YARD SETBACK OR 5' MINIMUM FROM THE SIDE P/L-- FIELD VERIFY. 2019 CALIFORNIA BUILDING CODE. Process Summary 1 17 �1 Applied to Approved Approved to Issued CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT TESERRA P 0 BOX 1280 COACHELLA CA 92236 (760)340-9000 KEVING@TESERRAOUT DOORS.COM CONTRACTOR TESERRA P 0 BOX 1280 COACHELLA CA 92236 (760)340-9000 KEVING@TESERRAOUT DOORS.COM OWNER Beazer P 0 BOX 1280 COACHELLA CA 92236 (760)340-9000 KEVING@TESERRAOUT DOORS.COM FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY RE -INSPECTION FEE 101-0000-42400 0 $83.37 $83.37 8/16/22 R71670 172548 CHECK TESERRA EMO Printed: Thursday, July 06, 2023 10:38:50 AM 1 of 6 CRWSYSTEMS Permit Details PERMIT NUMBER City of La Quinta BPOL2022-0182 11 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ ■ PAID BY CLTD BY RE -INSPECTION FEE 101-0000-42400 0 $83.37 $83.37 8/25/22 R71847 172836 CHECK TESERRA JLIM Total Paid for ADMINISTRATIVE: $166.74 $166.74 BSAS 5B1473 FEE 101-0000-20306 0 $1.00 $1.00 5/17/22 R70514 171145 CHECK TESERRA AHI Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 $1.00 SWIMMING POOL/SPA/WATER FEATURE 101-0000-42404 0 $208.41 $208.41 5/17/22 R70514 171145 CHECK TESERRA AHI SWIMMING POOL/SPA/WATER FEATURE PC 101-0000-42600 0 $113.38 $113.38 5/17/22 R70514 171145 CHECK TESERRA AHI Total Paid for POOL / SPA 2021: $321.79 $321.79 MANAGEMENT FEE RECORDS 101-0000-42416 0 $11.00 $11.00 5/17/22 [R70514 171145 CHECK TESERRA AHI Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 ENHANCEMENT FEE TECHNOLOGY 502-0000-43611 0 $5.00 $5.00 5/17/22 R70514 171145 CHECK TESERRA AHI Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: $505.53 $505.53 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES FINAL**BLD eTRAKiT Inspection Request 8/11/2022 2:41 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM Printed: Thursday, July 06, 2023 10:38:50 AM 2 of 6 CRWSYSTE S 141 Permit Details City of La Quinta PERMIT NUMBER BPOL2022-018 PRE-GUNITE MHU 5/31/2022 5/31/2022 DISAPPROVE D eTRAKiT Inspection Request 5/27/2022 10:40 AM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM 3" MINIMUM CLEARANCE REBAR TO EARTH AT SHALLOW END RAMP PRE-GUNITE MHU 6/1/2022 6/1/2022 APPROVED eTRAKiT Inspection Request 5/31/2022 2:47 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM UNDERGROUND PLBG MHU 6/16/2022 6/16/2022 APPROVED eTRAKiT Inspection Request 6/15/2022 3:20 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM UNDERGROUND GAS MHU 6/16/2022 6/16/2022 APPROVED eTRAKiT Inspection Request 6/15/2022 3:20 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM Printed: Thursday, July 06, 2023 10:38:50 AM 3 of 6 CRWSYSTE S Permit Details City of La Quinta PERMIT NUMBER BPOL2022-018� UNDERGROUND ELEC MHU 6/16/2022 6/16/2022 APPROVED eTRAKiT Inspection Request 6/15/2022 3:20 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM DECK BOND MHU 7/14/2022 7/14/2022 DISAPPROVE D eTRAKiT Inspection Request 7/13/2022 6:32 AM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM EQUIPOTENTIAL BONDING 4 POINTS OF CONNECTION TO BE EQUIDISTANT AROUND POOL DECK BOND MHU 7/15/2022 7/15/2022 APPROVED eTRAKiT Inspection Request 7/14/2022 3:31 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM PRE -PLASTER MHU 7/27/2022 7/27/2022 APPROVED eTRAKiT Inspection Request 7/26/2022 6:26 AM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM Printed: Thursday, July 06, 2023 10:38:50 AM 4 of 6 CRWSYSTE S Permit Details City of La Quinta PERMIT NUMBER BPOL2022-018 FINAL** MHU 8/11/2022 8/11/2022 DISAPPROVE D eTRAKiT Inspection Request 8/10/2022 3:26 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM SIDE GATE DOES NOT MEET SELF CLOSING/LATCHING REQUIREMENTS EMT CONDUIT NEEDS A GROUND BUSHING FINAL** MHU 8/15/2022 8/15/2022 DISAPPROVE D eTRAKiT Inspection Request 8/12/2022 3:03 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603899222 e-Mail: KEVING@TESERRAOUTDOORS.COM SIDE GATE DOE NOT MEET SELF CLOSING/SELF LATCHING REQUIREMENTS SUB PANEL DEAD FRONT TO BE REMOVED FOR INSPECTION RE INSPECTION FEE TO BE ASSESSED RE -INSPECTION ASSESSED. FEE WAS ADDED. CUST CAME IN TO PAY. FINAL** BLAK 1/17/2023 1/17/2023 DISAPPROVE D eTRAKiT Inspection Request 1/13/2023 3:01 PM TESERRA Contact Name: TESERRA Site Address: 58181 CORAL VIEW WAY Phone: 7603409000 e-Mail: KEVING@TESERRAOUTDOORS.COM Inspector MHU changed the inspection assignment from MHU to BLAK Printed: Thursday, July 06, 2023 10:38:50 AM 5 of 6 CRWSYSTEMS Permit Details City of La Quinta FINAL** BLAK 1/17/2023 1/17/2023 DISAPPROVE D eTRAKiT Inspection Request Need panel open at time of inspection to verify wiring bonding etc.Need to label main panel breaker.Also need to install door alarms for final inspection.Need to secure all conduit within 12 inches from the box or panel.Need a proved fitting from conduit to flexible liquid tight conduit's and secure conduit.Need approved double principal call auto fill valve installed along with approved shut off valve.Cover holes at aqua link panel are in.Pump leaking at connection. REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE I RETURNEDDATE STATUS REMARKS NOTES 1ST BLDG NS - ETRAKIT (1 DAY) JULIO ANAYA 4/29/2022 5/2/2022 5/16/2022 APPROVED BOND INFORMATION ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 4/29/2022 Etrakit Contractor 1ST SUBMITTAL SITE PLAN CANTERA LOT 45.pdf 1 DOC 5/16/2022 JULIO ANAYA SITE PLAN (APPROVED) BPOL2022 0182 SITE PLAN (APPROVED).pdf 1 Printed: Thursday, July 06, 2023 10:38:50 AM 6 of 6 CRWSYSTE S PL SPECIFICATIONS GUNITE SIZE 43' 0" 15' 0" X 38822 EL DESIERTO RD. PALM DESERT C PH: (760) 34❑-9000 FAX: (760)S39ER8-9A29525 21 1 CA LICENSE No. 6561 28 eJJu%L C%P44,0 c.. l fLZi G 6G4QO.4i 'fh,h.ty„ SURFACE AREA OF POOL ONLY 645 SQ.FT. 2284 SQ. FT. POOL AREA CONCRETE DECKING PERIMETER 116 LN.FT. DEPTHS MIN 4'-0" MAX 7'-0" BPOL2022-0182 117'-9" POOL & SPA COMBINED SQ.FT. / LN.FT. SPA SPECIFICATIONS TILE GLASS TILE SIZE - X - SQ. FT. - LN. FT - WATERLINE YES SPA DAM WALL WIDTH R.B.B. TILE NO. OF JETS LIGHT TRIM TILE RAISED SPA AT SPILLWAY TYPE SPECIAL NOTES DECKING SQ. FT. SEE NOTES EXCAVATION / STEEL 60" BOBCAT FINISH BROOM TYPE SEE SUPER EXPANSION JOINTS YES ACCESS FROM SEE SUPER CANTILEVER YES ELEVATION DOUBLE CANTILEVER DEEP END RAMP LOVE SEAT DRAINS STUB TO SIDE OF DECK CI lY OF LA QU N TA BU LCI N GCI VI 9 ON REVI EVED FOR COCE calm 41 CE CONCRETE REMOVAL LOADS SLEEVES SOD REMOVAL LOADS STEPS TREE REMOVAL BY STEP FACE IRRIGATION REMOVAL BY TILE BASE IRRIGATION REPAIR SAND AND VISQUEEN BY, J.ANAYA D : 05/16/2022 POOL SPLIT MAIN DRAIN SUCTION MINIMUM 3' APART.ANTI-COVERS 10" ASME / ANSI APPROVED 6" R.B.B. FT. BANDS MOW STRIP 12" R.B.B. FT. EQUIPOTENTIAL BONDING GRID YES BEAZER / POOL FEATURES PRE -PLASTER POOL ENGINEERING VERIFY. NEW LOCATION EITHER MINIMUM FROM BUILDING CODE. AT REAR YARD. TWO DROWNING SAFETY AND BARRIERS REQUIRED TO BE INSTALLED AT INSPECTION. PLEASE PROVIDE WET STAMPED SHEET ON SITE FOR INSPECTION FIELD EQUIPMENT MUST BE LOCATED IN AN APPROVED WITHIN THE REAR YARD SETBACK OR 5' THE SIDE P/L--FIELD VERIFY. 2019 CALIFORNIA 18" R B B FT. 18" FT. WELDED WIRE MESH R.B.B. REBAR 30" R.B.B. FT. BARBECUE COUNTERTOP TAN SHELF DEPTH 12" WD ROCK POCKETS MASONRY COPING TYPE CANTILEVER CONCRETE CENTERS R.B.B. FACING SPILLWAY TYPE SIZE PLUMBING STEPS JANDY 460 SQ.FT. PROP. EXT. WALLS FILTER SIZE JANDY PLANTER WALL POOL PUMP SIZE 2.7HP VS AUT RETAINING WALLS BOOSTER PUMP SIZE EQUIP. WALLS 6-6 ADDL PUMP SIZE ADDL PUMP SIZE SEAT WALLS FIREPIT GAS STUB ONLY HEATER JANDY SIZE 400,000 BTU BARBECUE GAS AND ELECTRIC STUB ONLY CONTROL SYSTEM IQ904 P SAND SET PAVERS NATURAL GRAY BROOM FINISH CONCRETE DECKING 0" PL JANDY TRUE CLEAR STUCCO CHLORINATOR JANDY IQ20-A PAINT '—/ ! WIRELESS CONTROL 6 US • 4'-0" WD • SKMTYPORT FILLIMLINE MPPE PRODUCTSDUAL AUTOFILL B B F L_/ PLASTER GAS LINEER F.M. STUBS BBQ/FIREPIT LI H 15 N OL(5) JANDY HYDROCOOL 12 W LED 19'SB. / 12" WD 4'-6" WD 15' 7' 0" Wp LIGHTS SPA W.F. ATTACHED TO POOL EYE BALL FITTINGS US • OTHER W.F. ' — —1 — I LIGHTS IN POOL( 5 ) JANDY HYDROCOOL 12W LED ECLIPSE DRAINS DEEP HEAT RETURNS LIGHTS IN SPA ANTI VORTEX Q360 INFLOOR / 43' / LIGHTS IN W F STUB SET EQUIPMENT VERSA FLOW FENCING PLUMBING SIZE21/2"SUCTION&21/2"RETURN FENCE TYPE BY OTHERS \�/ \�/ \�/ \�/ \�/ / NATURAL GRAY BROOM FINISH DEEP HEAT PACKAGE HEIGHT o �A o, CONCRETE DECKING / ECLIPSEQ360 ECLIPSE DRAINS GATE GATE REVERSAL ALUMAWOOD PATIO COVER BY ANDY VALLEY PATIOS ANTI VORTEX REMOVE & REHANG MISC. GUNITE DEEP END RAMP 146' - 2" POLYPROPYLENE EST. START GAS PIPE TO GAS STUBS 25' EXTEND 2nd STEP EST. COMPLETION LOVESEAT COPING CANTILEVER CONCRETE MISCELLANEOUS R.B.B. - SEE STEEL MISTING SYSTEM POOL / SPA LIGHT JUNCTION BOX POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER — ; I — ------ �-------��_�A=— ---o�_ -----o _-- ---------- i I _---------L—���---ou_oA=�� \.‘ I I TRELLIS oWNNER RESPONSIBILITIES DAY (2) TAKE NOITICE NE THAT POOL(1) THEIMATE AND EQUIPMEINT ON LOCATIONS ARE SUBJECTOF POOL R SPA ATOUT TO AOCCEPTAN ONCE F OFVATION. LOCAL BUILDING DEPARTMENT AT THE TIME OF ISSUANCE OF PERMIT. (3) WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR SEVEN DAYS AFTER SHELL IS INSTALLED. (4) AGREE THAT TESERRA IS AND ANY DAMAGE O CURBOT S, SIDEWAILKS, DRIVEWAYS,SIBLE R LAWNS,RGROUND LAWNS, OR OTHER ITEMS IN THEOR JECTS, ACCESS AREA. (5) SEE THAT ALL FENCING, GATES, AND GARAGE DOORS MEET LOCAL CODES FOR A POOL ENCLOSURE (6) PRIOR TO PREPLASTER INSPECTION. FILL POOL IMMEDIATELY AFTER PLASTER. ( FOLLOW INSTRUCTIONS -- DO NOT USE RUBBER HOSE ) (7) TAKE NOTICE THAT THIS DRAWING IS THE SOLE PROPERTY OF TESERRA AND THAT ANY USE WITHOUT WRITTEN PERMISSION OF TESERRA IS PROHIBITED BY LAW. OWNER APPROVES PLAN, POOL, AND EQUIPMENT LOCATIONS AND HAS READ THE RESPONSIBILITIES AND NOTICES ABOVE. SIGNATURE(S) DATE TRANSFORMER I I 196'-11" II -I a° ° ° GAS STUB FOR FUTURE FIRE PIT CA\TEA LOT 45 SPA AIR LINE I I 10' d< •p . ° . d • °. I i POOL EQUIPMENT 50 AMP SUBPANEL WITH 36" CLEARANCE AT FRONT AND r. r a ° a SIDE I A CUSTOM PROJECT FOR: 13' 23' NAME CA\TEA LOT 45 POOL EQUIPMENT: 400,000 BTU HEATER I COMMUNITY CANTERA JOB ADDRESS 58-181 CORAL VIEW WAY (CITY LA QUINTA *ALL EQUIPMENT SHALL BE �\1 - LO 45 &ELECTRIC HOMEOWNER MOBILE SEISMICALLY ANCHORED ,- GAS STUB FOR _ -�. HOMEOWNER EMAIL FUTURE BBQ •` ��•" � �;: S r PROJECT MANAGER MOBILE (760)250-3140 PROJECT MANAGER EMAIL Dylanp@teserraoutdoors.com I �)` CUSTOMER NUMBER: ELECTRIC CONDUIT 5' MIN t' PLAN 4BL ;.� '•< �� SCALE = 1 DATE 04,27,22 DESIGNED BY J,C❑❑L PROJECT MGR DYLAN P. CHECKED BY i. rig'-�''' MB # DBX# REVISIONS DATE: 50' - 1 1/2" POLYPROPYLENE GAS PIPE TO HEATER I SAFETY FEATURES: a Y 1 I 151' 3" ALL ANTI -ENTRAPMENT COVER INSTALLATION MEETING CURRENT STANDARDS OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS OR THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) 1 I �� EXISTING 5'-O"FI = / BLOCK WALL ELECTRICAL. EQUIPOTENTIAL BONDING REQUIREMENTS SHALL BE INSTALLED TO ELIMINATE VOLTAGE GRADIENTS IN THE POOL AREA AS PER CEC ART. 680.26. 3 20 1 9 CALIFORNIA RESIDENTIAL CODE ( BASED ON2018IRC) 4 GAS METER i I i 201 9 CALIFORNIA BUILDING CODE ( BASED ON 2018 IBC ) 20 1 9 CALIFORNIA MECHANICAL CODE ( BASED ON 2018 UMC ) EXISTING 5'-0"H SELF LATCHING 20 1 9 CALIFORNIA PLUMBING CODE ( BASED ON2018UPC ) TITLE 24,PART e SELF CLOSING GATE -OPENING OUT I I I I I 20 1 9 CALIFORNIA ELECTRICAL CODE ( BASED ON 2017 NEC ) 20 1 9 CALIFORNIA ENERGY GREEN CODE 201 9 CALIFORNIA ENERGY CODE 6 7 I GOVERNMENT CODE SECTION 4216.2. (a) (1) EXCEPT IN AN EMERGENCY, ANY PERSON PLANNING TO CONDUCT ANY EXCAVATION SHALL CONTACT THE APPROPRIATE REGIONAL O MAIN HOUSE 200 AMP ELECTRICAL PANEL I NOTIFICATION CENTER, AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14 CALENDAR DAYS, PRIOR COMMENCING THAT EXCAVATION, IF THE EXCAVATION WILL BE CONDUCTED SELECTIONS IN AND AREA THAT IS KNOWN, OR REASONABLY SHOULD BE KNOWN, TOCONTAIN SUBSURFACE INSTALLATIONS OTHER THAN THE UNDERGROUND FACILITIES OWNED OR OPERATED BY THE EXCAVATOR AND IF PRACTICAL, THE EXCAVATOR SHALL DELINEATE WHIT WHITE PAINT OR OTHER SUITABLE MARKING THE AREA TO BE EXCAVATED EXISTING 5'-0"H STONE I BLOCK WALL CONSTRUCTION AUTHORIZATION TILE INSTALLATION OF POOL SYSTEMS AND EQUIPMENT WILL WITH ' `1°�' COMPLY SECTION 114 MANDATORY REQUIREMENTS �� SALES FIELD PAVERS - � 140110; EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS DIG CONCRETE TO THE POOL PRE-GUNITE POTS/BOWLS 1 ' UNDERGROUND POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S •�`J ° / PEBB/PEAS RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS L---. . °MASONRY 4 4 ° ° 1 BOULDERS a a ° i a ALL DECKING EXPANSION JOINTS FOR REPRESENTATION ONLY, L ►6' 9" DECK DRAINAGE NOTE: Drainage and irrigation for planters and pots, by others, unless otherwise noted. FIELD LAYOUT WILL VARY a°• a a a °. AA PRE -PEBBLE Z: \_DRAWINGS\2022\DYLAN\C\CANTERA MODELS\LOT 45\HARDSCAPE\CANTERA LOT 45 HARDSCAPE 04-27-22.DWG _JASONC_4.27.2022