Loading...
BRER2020-0190gin Permit Details PERMIT NUMBER City of La Quinta BRER2020-0190 Description: LEE / REROOF NEW SHINGLES Type: RE -ROOF (WEB) Subtype: Status: ISSUED Applied: 12/7/2020 ECON Approved: 12/10/2020 AHI Issued: 12/10/2020 ONLINE Finaled: Expired: 6/9/2021 AOR Parcel No: 773333022 Site Address: 52905 AVENIDA VILLA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 147 Lot: 9 UNIT 15 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $7,200.00 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: REROOF WITH SHINGLES AT SLOPED AREAS [CRRC: 0890-0009] PER 2019 CALIFORNIA ENERGY CODE. 3 Process Summary Applied to Approved Approved to Issued ADDITIONAL SITES ■ ; • 1 • • CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AARON HICKSON 12/7/2020 12/7/2020 EMAILED APPLICANT CF1R FORM AND BUSINESS LICENSE APPLICATION RECEIVED CF1R 1.11 CONDITIONS CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT DOVE ROOFING AND CONSTRUCTION 6402 Sunburst JOSHUA TREE ca 92252 (176)070-2763 doveroofing@gmail.co m CONTRACTOR DOVE ROOFING AND CONSTRUCTION 6402 SUNBURST JOSHUA TREE (176)070-2763 DOVEROOFING@GMAI L.COM OWNER LORI C LEE 52905 AVENIDA VILLA LA QUINTA CA 92253 (176)070-2763 FINANCIAL INFORMATION Printed: Monday, May 22, 2023 12:28:52 PM 1 of 3 CRWSYSTEMS Permit Details City of La Quinta DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ ■ PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 12/10/20 WEB6959 2ZHK1I CREDIT DOVE ROOFING AND CONSTRUCTION ECON Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 BSA: $1.00 RECORDS MANAGEMENT FEE 101-0000-42416 0 $10.00 $10.00 12/10/20 WEB6959 2ZHK1I CREDIT DOVE ROOFING AND CONSTRUCTION ECON Total Paid for RECORDS MANAGEMENT FEE: $10.00 $10.00 RE ROOF EA ADDITIONAL 1,000SF 101-0000-42404 0 $12.88 $12.88 12/10/20 WEB6959 2ZHK1I CREDIT DOVE ROOFING AND CONSTRUCTION ECON RE ROOF FIRST 2,000SF 101-0000-42404 0 $54.74 $54.74 12/10/20 WEB6959 2ZHK1I CREDIT DOVE ROOFING AND CONSTRUCTION ECON RE ROOF FIRST 2,000SF PC 101-0000-42600 0 $109.48 $109.48 12/10/20 WEB6959 2ZHK1I CREDIT DOVE ROOFING AND CONSTRUCTION ECON Total Paid for RE -ROOF 2019: $177.10 $177.10 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 I 0 I $5.00 I $5.00 I 12/10/20 WEB6959 I 2ZHK1I CREDIT DOVE ROOFING AND CONSTRUCTION ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: $193.10 $193.10 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES PRE -ROOF AOR 12/11/2020 12/11/2020 APPROVED PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE I REDATE STATUS REMARKS NOTES Printed: Monday, May 22, 2023 12:28:52 PM 2 of 3 CRWSYSTE S P. Permit Details City of La Quinta PERMIT NUMBER BRER2020-0190ma 1ST PERMIT TECH — ETRAKIT (1 DAY) AARON12/7/2020 12/8/2020 12/10/2020 COMPLETE HICKSON 1v ATTACHMENTS J Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/10/2020 AARON HICKSON REROOF CF1R.pdf REROOF CF1R.pdf 0 Printed: Monday, May 22, 2023 12:28:52 PM 3 of 3 CRWSYSTEMS STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF1 R-ALT-05-E (Revised 01120) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 1of3 Project Name: Date Prepared: This compliance document is only applicable to simple alterations that do not require HERS verification for compliance. When HERS verification is required, a CF1R-ALT- 01 shall first be registered with a HERS Provider Data Registry. Alterations to Space Conditioning Systems that are exempt from HERS verification requirements may use the CF1R-ALT-05 and CF2R- ALT-05 Compliance Documents. Possible exemptions from duct leakage testing include: less than 40 ft of ducts were added or replaced; or the existing duct system was insulated with asbestos; or the existing duct system was previously tested and passed by a HERS Rater. If space conditioning systems are altered and are not exempt from HERS verification, then a CF1R-ALT-02 must be completed and registered with a HERS Provider Data Registry. Alterations that utilize close Cell Spray Polyurethane Foam (ccSPF) with a density of 1.5 to less than 2.5 pounds per cubic foot having an R-value greater than 5.8 per inch, or Open Cell Spray Polyurethane Foam (ocSPF) with a density of 0.4 to less than 1.5 pounds per cubic foot having an R-value of 3.6 per inch, shall complete and register a CF1R-ALT-01 with a HERS Provider Data Registry. If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures shall be met. Temporary labels shall not be removed before verification by the building inspector. A. General Information 01 Project Name: 02 Date Prepared: 03 Project Location: 04 Building Front Orientation (deg or cardinal): 05 CA City: 06 Number of Altered Dwelling Units: 07 Zip Code: 08 Fuel Type: 09 Climate Zone: 15 10 Total Conditioned Floor Area (ft2): 11 Building Type: 12 Slab Area (ft2) 13 Project Scope (Select all that apply): U B. Insulation ❑ D. & E. Fenestration/Glazing - ADD G. Space Conditioning System (Heating, Cooling, Duct system) Lighting n C. Roof Replacement U D. & F. Fenestration/Glazing - REPLACE H. Water Heating System Include Mandatory Measures? CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2020 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF1 R-ALT-05-E (Revised 01/20) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 2 of 3 Project Name: Date Prepared: C. Roof Replacement (Prescriptive Alteration, Section 150.2(b)1H) 01 02 03 04 05 06 07 Method of Compliance Roof Pitch Add Row Exception CRRC Product ID Number Delete Row NOTES: Product Type R-value Deck Insulation Initial Solar Reflectance 08 1 09 Proposed Aged Solar Reflectance 10 11 12 13 Thermal Emittance Minimum Required SRI (Optional) Aged Solar Reflectance Thermal Emittance SRI (Optional) • Roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements. • Liquid field applied coatings must comply with installation criteria from Section 110.8(i)4. CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2020 STATE OF CALIFORNIA Prescriptive Residential Alterations That Do Not Require HERS Field Verification CEC-CF1 R-ALT-05-E (Revised 01120) CERTIFICATE OF COMPLIANCE CALIFORNIA ENERGY COMMISSION CF1R-ALT-05-E Prescriptive Residential Alterations That Do Not Require HERS Field Verification Page 3 of 3 Project Name: Date Prepared: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Company: Signature Date: Address: CEA/ HERS Certification Identification (if applicable): City/State/Zip: Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. , 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Company: Date Signed: Address: License: City/State/Zip: Phone: For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. CA Building Energy Efficiency Standards - 2019 Residential Compliance January 2020