BSOL2021-0197Permit Details
PERMIT NUMBER
City of La Quinta BSOL2021-0197
Description: EAST OF MADISON/ 16.1kW PV SYSTEM - (46) PANELS/(2) INV/SUB
Type: SOLAR (WEB) Subtype: Status: FINALED
Applied: 10/18/2021 ECON
Approved: 2/8/2022 JFU
Issued: 2/8/2022 DCL
Finaled: 10/21/2022 JAN
Expired:
Parcel No: 767700026 Site Address: 53845 HUMBOLDT BLVD LA QUINTA,CA 92253
Subdivision: TR 33076-2 Block: Lot: 74
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $58,000.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 16.1kW SOLAR ARRAY - (46) 350W LONG! SOLAR LR4-60HPB-350M PANELS W/ (2) SMA SUNNYBOY SB7.7-1SP-US-41 INVERTERS +
100A PV LOAD CENTER [920SF] 2019 CALIFORNIA BUILDING CODES.
255
Applied to Approved
Approved to Issued
Issued to Finaled
ADDITIONAL SITES
— CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
E-MAIL
JAKE FUSON
11/2/2021
11/2/2021
NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT
CORRECTION LIST VIA EMAIL.
E-MAIL
JAKE FUSON
2/8/2022
2/8/2022
NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND
PERMIT IS READY TO ISSUE.
LOCATION TRANSFER
JAKE FUSON
11/2/2021
11/2/2021
LINKED TO ADDRESS 53845 HUMBOLDT BLVD FROM 53805
HUMBOLDT.
RESUBMITTAL
JAKE FUSON
1/11/2022
1/11/2022
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY I STATE ZIP PHONE FAX EMAIL
APPLICANT
HEGGE ELECTRICAL CONTRACTORS
INC
83852 AVE 45
INDIO
CA
92201
sherryl@heggeelectrica
I.com
Printed: Thursday, July 27, 2023 11:54:25 AM
1 of 4
CRWSYSTEMS
Permit Details
City of La Quinta
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY I STATE I ZIP I PHONE ■ FAX I EMAIL
CONTRACTOR
OWNER
HEGGE ELECTRICAL CONTRACTORS
INC
EAST OF MADISON
83852 AVE 45
P 0 BOX 1482
INDIO
LA QUINTA
CA
CA
92201
0
sherryl@heggeelectrica
I.com
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$3.00
$3.00
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $3.00 $3.00
PV SYSTEM GREATER
THAN 10KW
101-0000-42403
0
$41.68
$41.68
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
PV SYSTEM GREATER
THAN 10KW PC
101-0000-42600
0
$41.68
$41.68
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
PV SYSTEM MISC
EQUIPMENT
101-0000-42403
0
$27.79
$27.79
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
PV SYSTEM MISC
EQUIPMENT PC
101-0000-42600
0
$27.79
$27.79
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for ELECTRICAL 2021: $138.94 $138.94
PERMIT ISSUANCE
101-0000-42404
0
$105.60
$105.60
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for PERMIT ISSUANCE: $105.60 $105.60
RECORDS
MANAGEMENT FEE
101-0000-42416
0
$11.00
$11.00
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
0
$5.00
$5.00
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
Printed: Thursday, July 27, 2023 11:54:25 AM
2 of 4
CRWSYSTEMS
Permit Details
City of La Quinta
PERMIT NUMBER
BSOL2021-0197
INSPECTION
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
ROUGH ELEC
DCL
2/24/2022
2/24/2022
DISAPPROVE
D
- PROVIDE SOLAR PV POWER SOURCE
LABELING AT ATTIC CONDUIT.
ROUGH ELEC
DCL
10/14/2022
10/14/2022
APPROVED
SOLAR FINAL**
DCL
10/14/2022
10/14/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
10/13/2022 9:42 AM HEGGE ELECTRICAL
CONTRACTORS INC
Contact Name: HEGGE ELECTRICAL
CONTRACTORS INC
Site Address: 53845 HUMBOLDT BLVD
Phone: 7607754855
e-Mail: Jim.Hegge@heggeelectrical.com
- REVISE PLANS AND MAIN SERVICE
ELECTRICAL PANEL PLACARD TO
ACCURATELY REFLECT THE LOCATIONS OF
MAIN SERVICE AND SOLAR PV EQUIPMENT. -
NUMBER 6 AWG WIRE USED FROM LOAD
CENTER TO INVERTER. PLEASE CLARIFY
INCREASE IN CONDUCTOR SIZE.- RATED AC
OUTPUT CURRENT SIGNAGE MISSING AT
MAIN SERVICE BACK FED BREAKER. REFER
TO PLAN SHEET 004.- PROVIDE LADDER FOR
ROOF ACCESS TO VERIFY PANEL WATTAGE,
CONDUCTOR TYPE/SIZE, AND BONDING.
ADDITIONAL CORRECTIONS MAY APPLY.
SOLAR FINAL**
JAN
10/21/2022
10/21/2022
APPROVED
PARENT PROJECTS
REVIEWS
1
1
1
1
1
1
1
Printed: Thursday, July 27, 2023 11:54:25 AM
3 of 4
CRWSYSTE S
Permit Details
111111111111 City of La Quints
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES•
1ST BLDG NS
ETRAKIT (1 DAY)
JAKE FUSON
10/18/2021
10/19/2021
11/2/2021
REVISIONS REQUIRED
SEE 1ST REVIEW CORRECTION LIST.
2ND BLDG NS —
ETRAKIT (1 WK)
JAKE FUSON
1/11/2022
1/18/2022
2/8/2022
APPROVED
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
10/18/2021
Etrakit Contractor
1ST SUBMITTAL SOLAR
PLAN
Lot 74 Ps-V10-14.pdf
1
DOC
1/11/2022
Etrakit Contractor
2ND SUBMITTAL SOLAR
PLAN
Lot 74 Ps -REV 11-23.pdf
1
DOC
1/11/2022
Etrakit Contractor
2ND SUBMITTAL
RESPONSES
RESPOPNSES- BSOL2021
-0197 - 1ST REVIEW
CORRECTION LIST.pdf
1
DOC
1/20/2022
Etrakit Contractor
REVISED SFD ENERGY
REPORT (FOR
REFERENCE ONLY)
BRE52021 0164-
REVISION 1 ENERGY
REPORT
(APPROVED).pdf
1
DOC
10/17/2022
Etrakit Contractor
003-SIGNAGE
DIAGRAM -LOT 74.pdf
1
DOC
11/2/2021
JAKE FUSON
1ST REVIEW
CORRECTION LIST
BSOL2021-0197 - 1ST
REVIEW CORRECTION
LIST.pdf
1
DOC
2/8/2022
JAKE FUSON
SOLAR PLAN
(APPROVED)
BSOL2021-0197 - SOLAR
PLAN (APPROVED).pdf
1
Printed: Thursday, July 27, 2023 11:54:25 AM
4of4
CRWSYSTEMS
FORMAT: WHITE LETTERING ON A RED BACKGROUND.(2) MINIMUM 3/8" LETTER HEIGHT.(3)ALL LETTERS SHALL BE CAPILAZIDED.(4)ARIAL OR SIMILAR FONT,
NON -BOLD. MATERIAL: REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARDS FOR WEATHER RATING)
DURABLE ADHESIVE MATERIAL MEETS THIS REQUIREMENT.
CAUTION
THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR
PANELS ON ROOF
LEGEND:
SERVICE PANEL OO AC DISCONNECT
3 SUBPANEL 4; INVERTER PV MODULES
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS OVERCURRENT DEVICE
RATED AC OUTPUT CURRENT 64.0 A
NOM OPERATING AC VOLTAGE 240 V
To be installed at the existing panel board
next to the backfed PV breaker
WARNING
INVERTER OUTPUT CONNECTION DO NOT
RELOCATE OVERCURRENT DEVICE
To be installed at inverter grounded systems
WARNING
ELECTRIC SHOCK HAZARD
IF GROUND FAULTS IS INDICATED
NORMALLY GROUNDED CONDUCTORS
MAY BE UNGROUNDED AND ENERGIZED
Conduits and Raceways
label every 10'
CAUTION: SOLAR CIRCUIT
To be installed at Solar AC disconnect
and any Toad centers.
SOLAR AC DISCONNECT
To be installed at the PV Subpanel.
WARNING:
THIS EQUIPMENT FED BY MULTIPLE SOURCES
TOTAL RATING OF ALL OVERCURRENT DEVICES
EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE
SHALL NOT EXCEED AMPACITY OF BUSBAR
To be installed on the face of service meter.
CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED
To be installed at inverter
MAXIMUM VOLTAGE
MAXIMUM CIRCUIT CURRENT
MAX RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER OR
DC -TO -DC CONVERTER (IF INSTALLED)
480 V
20.0 A
15 A
ONE ON EACH INVERTER
WARNING:
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE
LINE AND THE LOAD SIDES MAY
BE ENERGIZED IN THE OPEN
POSITION
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN I
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
The title "SOLAR PV SYSTEM IS
EQUIPPED WITH RAPID SHUTDOWN"
shall utilize capitalized characters with a
minimum height of 9.5 mm (3/8 in.) in black
on yellow background, and the remaining
characters shall be capitalized with a
minimum height of 4.8 mm (3/16 in.)in black
on white background(690.56(c))
To be installed outside or within 3' of the service panel board
To be installed next to the rapid
shutdown disconnect
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
Hegge Electrical
Contractor Inc.
Contractor
License Type C10
Lic # 748171
83-852 Ave. 45th
Indio, CA. 92201
Jim Hegge
Tel. 760-775-4855
jim@heggeelectrical.com
Contractor:
Jim Hegge
Signature
Revisions
Date
City Revisions
11-11-21
Equipment Location
10-17-22
M
rn
o
CO U
To
c U
E
(6 J
> ,
c.) cjIm
� co
c
o .0 ti °
O O
_c
0
co
1
M
Lf)
l
Legal Description:
APN # 779440017
Scale: NTS
Date: 10-13-21
Drawn by:
Solar Permit Design Services
Cell. 760-409-6289
solarpermitds@gmait com
Project No.
21-788
Sheet No.
004