Loading...
BSOL2021-0197Permit Details PERMIT NUMBER City of La Quinta BSOL2021-0197 Description: EAST OF MADISON/ 16.1kW PV SYSTEM - (46) PANELS/(2) INV/SUB Type: SOLAR (WEB) Subtype: Status: FINALED Applied: 10/18/2021 ECON Approved: 2/8/2022 JFU Issued: 2/8/2022 DCL Finaled: 10/21/2022 JAN Expired: Parcel No: 767700026 Site Address: 53845 HUMBOLDT BLVD LA QUINTA,CA 92253 Subdivision: TR 33076-2 Block: Lot: 74 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $58,000.00 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 16.1kW SOLAR ARRAY - (46) 350W LONG! SOLAR LR4-60HPB-350M PANELS W/ (2) SMA SUNNYBOY SB7.7-1SP-US-41 INVERTERS + 100A PV LOAD CENTER [920SF] 2019 CALIFORNIA BUILDING CODES. 255 Applied to Approved Approved to Issued Issued to Finaled ADDITIONAL SITES — CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL JAKE FUSON 11/2/2021 11/2/2021 NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT CORRECTION LIST VIA EMAIL. E-MAIL JAKE FUSON 2/8/2022 2/8/2022 NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND PERMIT IS READY TO ISSUE. LOCATION TRANSFER JAKE FUSON 11/2/2021 11/2/2021 LINKED TO ADDRESS 53845 HUMBOLDT BLVD FROM 53805 HUMBOLDT. RESUBMITTAL JAKE FUSON 1/11/2022 1/11/2022 CONDITIONS CONTACTS NAME TYPE NAME ADDRESS1 CITY I STATE ZIP PHONE FAX EMAIL APPLICANT HEGGE ELECTRICAL CONTRACTORS INC 83852 AVE 45 INDIO CA 92201 sherryl@heggeelectrica I.com Printed: Thursday, July 27, 2023 11:54:25 AM 1 of 4 CRWSYSTEMS Permit Details City of La Quinta CONTACTS NAME TYPE NAME ADDRESS1 CITY I STATE I ZIP I PHONE ■ FAX I EMAIL CONTRACTOR OWNER HEGGE ELECTRICAL CONTRACTORS INC EAST OF MADISON 83852 AVE 45 P 0 BOX 1482 INDIO LA QUINTA CA CA 92201 0 sherryl@heggeelectrica I.com FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $3.00 $3.00 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $3.00 $3.00 PV SYSTEM GREATER THAN 10KW 101-0000-42403 0 $41.68 $41.68 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON PV SYSTEM GREATER THAN 10KW PC 101-0000-42600 0 $41.68 $41.68 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON PV SYSTEM MISC EQUIPMENT 101-0000-42403 0 $27.79 $27.79 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON PV SYSTEM MISC EQUIPMENT PC 101-0000-42600 0 $27.79 $27.79 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON Total Paid for ELECTRICAL 2021: $138.94 $138.94 PERMIT ISSUANCE 101-0000-42404 0 $105.60 $105.60 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON Total Paid for PERMIT ISSUANCE: $105.60 $105.60 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 2/8/22 WEB10657 635277509 67 CREDIT HEGGE ELECTRICAL CONTRACTORS INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 Printed: Thursday, July 27, 2023 11:54:25 AM 2 of 4 CRWSYSTEMS Permit Details City of La Quinta PERMIT NUMBER BSOL2021-0197 INSPECTION SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES ROUGH ELEC DCL 2/24/2022 2/24/2022 DISAPPROVE D - PROVIDE SOLAR PV POWER SOURCE LABELING AT ATTIC CONDUIT. ROUGH ELEC DCL 10/14/2022 10/14/2022 APPROVED SOLAR FINAL** DCL 10/14/2022 10/14/2022 DISAPPROVE D eTRAKiT Inspection Request 10/13/2022 9:42 AM HEGGE ELECTRICAL CONTRACTORS INC Contact Name: HEGGE ELECTRICAL CONTRACTORS INC Site Address: 53845 HUMBOLDT BLVD Phone: 7607754855 e-Mail: Jim.Hegge@heggeelectrical.com - REVISE PLANS AND MAIN SERVICE ELECTRICAL PANEL PLACARD TO ACCURATELY REFLECT THE LOCATIONS OF MAIN SERVICE AND SOLAR PV EQUIPMENT. - NUMBER 6 AWG WIRE USED FROM LOAD CENTER TO INVERTER. PLEASE CLARIFY INCREASE IN CONDUCTOR SIZE.- RATED AC OUTPUT CURRENT SIGNAGE MISSING AT MAIN SERVICE BACK FED BREAKER. REFER TO PLAN SHEET 004.- PROVIDE LADDER FOR ROOF ACCESS TO VERIFY PANEL WATTAGE, CONDUCTOR TYPE/SIZE, AND BONDING. ADDITIONAL CORRECTIONS MAY APPLY. SOLAR FINAL** JAN 10/21/2022 10/21/2022 APPROVED PARENT PROJECTS REVIEWS 1 1 1 1 1 1 1 Printed: Thursday, July 27, 2023 11:54:25 AM 3 of 4 CRWSYSTE S Permit Details 111111111111 City of La Quints REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES• 1ST BLDG NS ETRAKIT (1 DAY) JAKE FUSON 10/18/2021 10/19/2021 11/2/2021 REVISIONS REQUIRED SEE 1ST REVIEW CORRECTION LIST. 2ND BLDG NS — ETRAKIT (1 WK) JAKE FUSON 1/11/2022 1/18/2022 2/8/2022 APPROVED BOND INFORMATION ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/18/2021 Etrakit Contractor 1ST SUBMITTAL SOLAR PLAN Lot 74 Ps-V10-14.pdf 1 DOC 1/11/2022 Etrakit Contractor 2ND SUBMITTAL SOLAR PLAN Lot 74 Ps -REV 11-23.pdf 1 DOC 1/11/2022 Etrakit Contractor 2ND SUBMITTAL RESPONSES RESPOPNSES- BSOL2021 -0197 - 1ST REVIEW CORRECTION LIST.pdf 1 DOC 1/20/2022 Etrakit Contractor REVISED SFD ENERGY REPORT (FOR REFERENCE ONLY) BRE52021 0164- REVISION 1 ENERGY REPORT (APPROVED).pdf 1 DOC 10/17/2022 Etrakit Contractor 003-SIGNAGE DIAGRAM -LOT 74.pdf 1 DOC 11/2/2021 JAKE FUSON 1ST REVIEW CORRECTION LIST BSOL2021-0197 - 1ST REVIEW CORRECTION LIST.pdf 1 DOC 2/8/2022 JAKE FUSON SOLAR PLAN (APPROVED) BSOL2021-0197 - SOLAR PLAN (APPROVED).pdf 1 Printed: Thursday, July 27, 2023 11:54:25 AM 4of4 CRWSYSTEMS FORMAT: WHITE LETTERING ON A RED BACKGROUND.(2) MINIMUM 3/8" LETTER HEIGHT.(3)ALL LETTERS SHALL BE CAPILAZIDED.(4)ARIAL OR SIMILAR FONT, NON -BOLD. MATERIAL: REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARDS FOR WEATHER RATING) DURABLE ADHESIVE MATERIAL MEETS THIS REQUIREMENT. CAUTION THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF LEGEND: SERVICE PANEL OO AC DISCONNECT 3 SUBPANEL 4; INVERTER PV MODULES POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE RATED AC OUTPUT CURRENT 64.0 A NOM OPERATING AC VOLTAGE 240 V To be installed at the existing panel board next to the backfed PV breaker WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE To be installed at inverter grounded systems WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULTS IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Conduits and Raceways label every 10' CAUTION: SOLAR CIRCUIT To be installed at Solar AC disconnect and any Toad centers. SOLAR AC DISCONNECT To be installed at the PV Subpanel. WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR To be installed on the face of service meter. CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED To be installed at inverter MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC -TO -DC CONVERTER (IF INSTALLED) 480 V 20.0 A 15 A ONE ON EACH INVERTER WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN I SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY The title "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" shall utilize capitalized characters with a minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3/16 in.)in black on white background(690.56(c)) To be installed outside or within 3' of the service panel board To be installed next to the rapid shutdown disconnect RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM Hegge Electrical Contractor Inc. Contractor License Type C10 Lic # 748171 83-852 Ave. 45th Indio, CA. 92201 Jim Hegge Tel. 760-775-4855 jim@heggeelectrical.com Contractor: Jim Hegge Signature Revisions Date City Revisions 11-11-21 Equipment Location 10-17-22 M rn o CO U To c U E (6 J > , c.) cjIm � co c o .0 ti ° O O _c 0 co 1 M Lf) l Legal Description: APN # 779440017 Scale: NTS Date: 10-13-21 Drawn by: Solar Permit Design Services Cell. 760-409-6289 solarpermitds@gmait com Project No. 21-788 Sheet No. 004