BMCH2019-0153Permit Details
City of La Quinta
Description: 2 TON 17 SEER
Type: MECHANICAL - HVAC Subtype: Status: FINALED
CHANGEOUT (WEB)
Applied: 4/30/2019 ECON
Approved: 4/30/2019 AHI
Issued: 4/30/2019 AHI
Finaled: 2/25/2020 crw
Expired:
Parcel No: 776050006 Site Address: 50480 ORCHARD LN LN LA QUINTA,CA 92253
Subdivision: PM 26525 Block: Lot: 3
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $550.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: HVAC CHANGE OUT - 17.SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION.
2016 CALIFORNIA BUILDING CODES.
Process Summary
301 0
0
i Applied to Approved
Approved to Issued
Issued to Finaled
ADDITIONAL
SITES A
CHRONOLOGY
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
ANTHEM MECHANICAL
53800 POLK STREET
COACHELLA
CA
92236
(760)895-2621
INFO@ANTHEMMECH
ANICAL.COM
CONTRACTOR
ANTHEM MECHANICAL
53800 POLK STREET
COACHELLA
CA
92236
(760)895-2621
INFO@ANTHEMMECH
ANICAL.COM
OWNER
TUTOR DAUGHTERS
(760)895-2621
FINANCIAL INFORMATION
Printed: Wednesday, June 28, 2023 11:19:26 AM
1 of 3
CRWSYSTE S
Permit Details
City of La Quinta
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
■ ■
PAID BY
CLTD
BY
BSAS 5B1473 FEE
101-0000-20306
0
$1.00
$1.00
4/30/19
WEB3632
CREDIT
ANTHEM
MECHANICAL
ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00
BSA:
$1.00
HVAC CHANGEOUT
SPLIT -SYSTEM
101-0000-42402
0
$40.02
$40.02
4/30/19
WEB3632
CREDIT
ANTHEM
MECHANICAL
ECON
HVAC CHANGEOUT
SPLIT -SYSTEM PC
101-0000-42600
0
$80.05
$80.05
4/30/19
WEB3632
CREDIT
ANTHEM
MECHANICAL
ECON
Total Paid for CHANGEOUT: $120.07
$120.07
Credit Card Fee
101-0000-43505
0
$4.09
$4.09
4/30/19
WEB3632
CREDIT
ANTHEM
MECHANICAL
ECON
Total Paid for Credit Card Fee: $4.09
$4.09
PERMIT ISSUANCE
101-0000-42404
0
$101.40
$101.40
4/30/19
WEB3632
CREDIT
ANTHEM
MECHANICAL
ECON
Total Paid for PERMIT ISSUANCE: $101.40
$101.40
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
I 0
$5.00
$5.00
4/30/19
WEB3632
CREDIT
ANTHEM MECHANICAL
ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
$5.00
TOTALS:
$231.56
$231.56
INSPECTIONS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
MECHANICAL FINAL**
CGAR
2/25/2020
2/25/2020
APPROVED
PARENT PROJECTS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE I REDATE
STATUS
REMARKS
NOTES
Printed: Wednesday, June 28, 2023 11:19:26 AM
2 of 3
CRWSYSTE S
*A.
Permit Details
City of La Quinta
PERMIT NUMBER
BMCH2O19-0153
1ST PERMIT TECH —
ETRAKIT (1 DAY)
PERMIT TECH4/30/2019 5/1/2019 I 4/30/2019
BUCKET
COMPLETE
isr
ATTACHMENTS
J
Attachment Type CREATED
OWNER I DESCRIPTION I PATHNAME
SUBDIR ETRAKIT ENABLED
DOC
4/30/2019
EtrakitContractor
cflr-ackeret.pdf
1
Printed: Wednesday, June 28, 2023 11:19:26 AM 3 of 3
CRWSYSTE S
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 1 of 3)
Project Name:
ACKERET jERRY
Date Prepared:
2019-04-30
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
ACKERETjERRY
02
Date Prepared
2019-04-30
03
Project Location
50480 Orchard Lane
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
ACKERETjERRY
07
Zip Code
92253
08
Dwelling Unit Conditioned
Floor Area (ftZ)
800
09
Climate Zone
15
10
Number of Space
Conditioning (SC) Systems in
this Dwelling Unit:
1
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System (ft2)
Is the SC
system a
ducted
system?
Installing a
refrigerant
containing
component?
Installing new SC
system
components?
Installing
more than 40
feet of ducts?
Installing
entirely new
duct system?
Installing
entirely new
SC system?
Alteration Type
System 1
Location 1
800
No
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 219-A020098602A-000-000-0000000-0000
Registration Date/Time: 2019-04-30 10:17:18
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001
Schema Version: rev 20180426
Report Generated: 2019-04-30 10:17:12
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
System
Identification
or Name
Heating
System
Type
Altered
Heating
Components
Heating
Efficiency
Type
Heating
Minimum
Efficiency
Value
Cooling
System Type
Altered
Cooling
Components
Cooling
Efficiency
Type
Cooling
Minimum
Efficiency
Value
Required
Thermostat
Type
New or
Replaced
Duct Length
New Duct
R-Value
System 1
Ductless
mini split HP
All new
heating
components
AFUE
80
Ductless
mini split AC
All new
cooling
components
SEER
17
Setback
This field or
section is not
applicable
This field or
section is not
applicable
Required Documentation:
Systems
new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
or <= 10 percent leakage to outside, or seal all accessible leaks.
Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
>= 300 CFM per ton required when MCH-25 is required.
provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
CF2R-MCH-01-E - Space
- Duct insulation requirement
CF2R and CF3R-MCH-20-H
-Leakage rate compliance:
CF2R and CF3R-MCH-25-H
CF2R and CF3R-MCH-23
Exceptions:
Conditioning
for the
- Duct Leakage
<= 15 percent
Refrigerant
Airflow Rate
with HERS
and Air Handler
constructed, insulated
- Duct systems registered
- Heating -only systems
-Existing duct systems
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 219-A020098602A-000-000-0000000-0000
Registration Date/Time: 2019-04-30 10:17:18
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2018.0.001 Report Generated: 2019-04-30 10:17:12
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 3 of 3)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Solomon, Michael
Documentation Author Signature: ,�A�
/�'(
Company:
ANTHEM MECHANICAL
Signature Date:
2019-04-30 10:17:18
Address:
53-800 POLK STREET
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
COACHELLA CA 92236
Phone:
760-469-2525
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Solomon, Michael
Responsible Designer Signature: /��i le �fv
Company :
ANTHEM MECHANICAL
Date Signed:
2019-04-30 10:17:18
Address:
53-800 POLK STREET
License:
1001659
City/State/Zip:
COACHELLA CA 92236
Phone:
760-469-2525
Digitally signed byCalCERTS. This digital signature isprovided in order to secure the content of this registered document, and in no wayimplies
9 Y 9 9 9. 9 P
Registration Provider responsibility for the accuracy of the information.
Easy to Verify 0 0
at CaICERTS.com
0_ 0
Registration Number: 219-A020098602A-000-000-0000000-0000
Registration Date/Time: 2019-04-30 10:17:18
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2018.0.001
Schema Version: rev 20180426
Report Generated: 2019-04-30 10:17:12
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 1 of 3)
Project Name:
ACKERET jERRY
Date Prepared:
2019-04-30
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
ACKERETjERRY
02
Date Prepared
2019-04-30
03
Project Location
50480 Orchard Lane
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
ACKERETjERRY
07
Zip Code
92253
08
Dwelling Unit Conditioned
Floor Area (ftZ)
800
09
Climate Zone
15
10
Number of Space
Conditioning (SC) Systems in
this Dwelling Unit:
1
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System (ft2)
Is the SC
system a
ducted
system?
Installing a
refrigerant
containing
component?
Installing new SC
system
components?
Installing
more than 40
feet of ducts?
Installing
entirely new
duct system?
Installing
entirely new
SC system?
Alteration Type
System 1
Location 1
800
No
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 219-A020098602A-000-000-0000000-0000
Registration Date/Time: 2019-04-30 10:17:18
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001
Schema Version: rev 20180426
Report Generated: 2019-04-30 10:17:12
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
System
Identification
or Name
Heating
System
Type
Altered
Heating
Components
Heating
Efficiency
Type
Heating
Minimum
Efficiency
Value
Cooling
System Type
Altered
Cooling
Components
Cooling
Efficiency
Type
Cooling
Minimum
Efficiency
Value
Required
Thermostat
Type
New or
Replaced
Duct Length
New Duct
R-Value
System 1
Ductless
mini split HP
All new
heating
components
AFUE
80
Ductless
mini split AC
All new
cooling
components
SEER
17
Setback
This field or
section is not
applicable
This field or
section is not
applicable
Required Documentation:
Systems
new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
or <= 10 percent leakage to outside, or seal all accessible leaks.
Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
>= 300 CFM per ton required when MCH-25 is required.
provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
CF2R-MCH-01-E - Space
- Duct insulation requirement
CF2R and CF3R-MCH-20-H
-Leakage rate compliance:
CF2R and CF3R-MCH-25-H
CF2R and CF3R-MCH-23
Exceptions:
Conditioning
for the
- Duct Leakage
<= 15 percent
Refrigerant
Airflow Rate
with HERS
and Air Handler
constructed, insulated
- Duct systems registered
- Heating -only systems
-Existing duct systems
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 219-A020098602A-000-000-0000000-0000
Registration Date/Time: 2019-04-30 10:17:18
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2018.0.001 Report Generated: 2019-04-30 10:17:12
Schema Version: rev 20180426
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 3 of 3)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Solomon, Michael
Documentation Author Signature: ,�A�
/�'(
Company:
ANTHEM MECHANICAL
Signature Date:
2019-04-30 10:17:18
Address:
53-800 POLK STREET
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
COACHELLA CA 92236
Phone:
760-469-2525
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Solomon, Michael
Responsible Designer Signature: /��i le �fv
Company :
ANTHEM MECHANICAL
Date Signed:
2019-04-30 10:17:18
Address:
53-800 POLK STREET
License:
1001659
City/State/Zip:
COACHELLA CA 92236
Phone:
760-469-2525
Digitally signed byCalCERTS. This digital signature isprovided in order to secure the content of this registered document, and in no wayimplies
9 Y 9 9 9. 9 P
Registration Provider responsibility for the accuracy of the information.
Easy to Verify 0 0
at CaICERTS.com
0_ 0
Registration Number: 219-A020098602A-000-000-0000000-0000
Registration Date/Time: 2019-04-30 10:17:18
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2018.0.001
Schema Version: rev 20180426