2022-11-28 Patio Cover City Standard - AHicksonFrom:
Aaron Hickson
Sent:
Monday, November 28, 2022 8:56 AM
To:
dennissadorra@gmail.com
Subject:
BRES2022-0881 43810 SKYWARD WAY
Attachments:
PATIO COVER CITY STANDARD.pdf
Good morning,
Regarding the above permit submittal. This is incomplete and the
incorrect permit types. We can keep the permit number above for the
window change out. But we will require the CF1R form to be uploaded to
the permit number above for review.
For the Flagpole apply for a STRUCTURE OTHER THAN BUILDING (WEB)
permit. We will require a site plan, the footing engineering, and HOA
approval for review.
The patio cover will be a PATIO COVER (WEB) permit. This will also
require a site plan. Showing the patio cover dimensions, Post distances,
overhang length, and set backs. This will also require engineering for
review. I have attached the city standard form. You can complete and
upload of this is how the patio cover will be constructed. Otherwise site
specific engineering is required.
Have a great day.
1
Aaron Hickson I Permit Technician
City of La Quinta
Design & Development
78495 Calle Tampico
Ph. 760.777.7087
Division
_a Quinta, CA 92253
www.laquintaca.gov
www.playinlaguinta.com
CITY STANDARD FOR PATIO COVER
r - RAFTER SIZE AND
SPACING
SPECIFY ROOFING AND SHEATHING OR OPEN LATT1.'E �
_--_--- -----_----
(SEE ROOFING NOTE ON REVERSE)
/
/
---_--_------__-_-_-
/
ROOF PITCH
CONTINUOUS LEDGER
(SAME SIZE AS RAFTERS)
HEADER SIZE
AND 'L' STRAPS
�
------- -. -_--
6' s6'.t"vt/8" WITH
=
I (4) 160 NAILS OR BOLT
RAFTER SPAN:
-
O.H. s
POST $PACING -_
O.H.
-+
U
OVERALL LENGTH:
a
OVERALL LENGTH
I
• POST SIZE.
REAR SETBACK SIDE SETBACK
I
(4"r4" MIN.)
2000 P,S.I CONCRETE ---.r
I FINISH GRADE FINISH GRADE
L_J I
L_ JL•-- MIN, 12%12" FOOTING I I
I!
12' BELOW GRADE L _ J
PROVIDE 1" CLEARANCE
BETWEEN POST AND
NOTE'
CONCRETE —��
OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING FASCIA
VIA ONE 1/4' x 5" LAG SCREW THROUGH FASCIA INTO EACH RAFTER TAIL,
U-STRAP OR AN
5" LAG SCREWS INTO STUDS AT 16" O.C.] NON -CORROSIVE
r — CONTINUOUS LEDGER /
JOIST HANGER OR SOLID BLOCKING
NAIL RAFTER TO BLOCKING
i
(4)= 16d NAILS
OR BOLT _
U-STRAP OR ANGLE —
(4)- 16d NAILS
OR BOLT
PROVIDE 1" CLEARANCE
BETWEEN POST AND
CONCRETE
ANCHOR BOLT (EMBED -
7" MIN. INTO CONCRETE)
78495 CALLE TAMPICO - LA QUINTA, CA 92253 - 760-777-7000
WWW.LA UINTACA.GOV
RAFTER SPAN TABL
GRADING RULES
PS 20-70
(FEET & INCHES)
o
o' �0'��
c� p
2x4
16" O.C.
24'
] -
� Q'-
" °'-0" I
8,_
�„
_
„
2x6
16" O.C.
24" "
32" "
1 -
14'-
0'-
1
1 -
11'- "
-9"
1 -
1 -
-6"
A
N/A
2x8
16" O.C.
24' "
32" "
18'- "
17'- "
1 '-6"
I6'- "
18,_6„
-6"
11'-0"
13'-0'.
-
1
N/A
N _A
NOTES:
1. 32" RAFTER SPACING IS ALLOWABLE
FOR OPEN LATTICE PATIO COVERS ONLY,
2. FOR SOLID PATIO COVERS (NOT LATTICE)
RAFTER SPAN IS LIMITED TO 10'-O" USING
THIS STANDARD.
LATTICE
ROOF
BUILT-UP ROOF
I HEADERS
HEADERS
DOUGLAS'
FIR NO, 1
DOUGLAS FIR NO, 1
SIZE
SPAN
SIZE SPAN
`I
€ 4x4'-C_
4x4 4'-0"
` 4x6
8'-C"
4x6 E'-0"
4x8
111-0'
4x8 -5.-F
4x10
14'-O"
4x10 10'-0.1
412- _'_17---Q
412_ 12'-0''
I 6x8
14'-0"
6x8 12'--0"
600
17'-0'
6x10 14'- IT
R00FING NOTES:
A, BUILT-UP, ROLLED ROOF: SLOPE TO DRAIN.
B. ROCK ROOF: 3i 12 MAXIMUM PITCH.
• PER 2016 CALIFORNIA BUILDING CODE
• DESIGNS OTHER THAN THE CITY STANDARD ARE POSSIBLE WITH SITE SPECIFIC ENGINEERING
78495 CALLE TAMPICO - LA QUINTA, CA 92253 - 760-777-7000
NIW1J. LAgUI NTACA,GOV