Loading...
2022-11-28 Patio Cover City Standard - AHicksonFrom: Aaron Hickson Sent: Monday, November 28, 2022 8:56 AM To: dennissadorra@gmail.com Subject: BRES2022-0881 43810 SKYWARD WAY Attachments: PATIO COVER CITY STANDARD.pdf Good morning, Regarding the above permit submittal. This is incomplete and the incorrect permit types. We can keep the permit number above for the window change out. But we will require the CF1R form to be uploaded to the permit number above for review. For the Flagpole apply for a STRUCTURE OTHER THAN BUILDING (WEB) permit. We will require a site plan, the footing engineering, and HOA approval for review. The patio cover will be a PATIO COVER (WEB) permit. This will also require a site plan. Showing the patio cover dimensions, Post distances, overhang length, and set backs. This will also require engineering for review. I have attached the city standard form. You can complete and upload of this is how the patio cover will be constructed. Otherwise site specific engineering is required. Have a great day. 1 Aaron Hickson I Permit Technician City of La Quinta Design & Development 78495 Calle Tampico Ph. 760.777.7087 Division _a Quinta, CA 92253 www.laquintaca.gov www.playinlaguinta.com CITY STANDARD FOR PATIO COVER r - RAFTER SIZE AND SPACING SPECIFY ROOFING AND SHEATHING OR OPEN LATT1.'E � _--_--- -----_---- (SEE ROOFING NOTE ON REVERSE) / / ---_--_------__-_-_- / ROOF PITCH CONTINUOUS LEDGER (SAME SIZE AS RAFTERS) HEADER SIZE AND 'L' STRAPS � ------- -. -_-- 6' s6'.t"vt/8" WITH = I (4) 160 NAILS OR BOLT RAFTER SPAN: - O.H. s POST $PACING -_ O.H. -+ U OVERALL LENGTH: a OVERALL LENGTH I • POST SIZE. REAR SETBACK SIDE SETBACK I (4"r4" MIN.) 2000 P,S.I CONCRETE ---.r I FINISH GRADE FINISH GRADE L_J I L_ JL•-- MIN, 12%12" FOOTING I I I! 12' BELOW GRADE L _ J PROVIDE 1" CLEARANCE BETWEEN POST AND NOTE' CONCRETE —�� OPEN LATTICE PATIO COVERS MAY BE ATTACHED TO EXISTING FASCIA VIA ONE 1/4' x 5" LAG SCREW THROUGH FASCIA INTO EACH RAFTER TAIL, U-STRAP OR AN 5" LAG SCREWS INTO STUDS AT 16" O.C.] NON -CORROSIVE r — CONTINUOUS LEDGER / JOIST HANGER OR SOLID BLOCKING NAIL RAFTER TO BLOCKING i (4)= 16d NAILS OR BOLT _ U-STRAP OR ANGLE — (4)- 16d NAILS OR BOLT PROVIDE 1" CLEARANCE BETWEEN POST AND CONCRETE ANCHOR BOLT (EMBED - 7" MIN. INTO CONCRETE) 78495 CALLE TAMPICO - LA QUINTA, CA 92253 - 760-777-7000 WWW.LA UINTACA.GOV RAFTER SPAN TABL GRADING RULES PS 20-70 (FEET & INCHES) o o' �0'�� c� p 2x4 16" O.C. 24' ] - � Q'- " °'-0" I 8,_ �„ _ „ 2x6 16" O.C. 24" " 32" " 1 - 14'- 0'- 1 1 - 11'- " -9" 1 - 1 - -6" A N/A 2x8 16" O.C. 24' " 32" " 18'- " 17'- " 1 '-6" I6'- " 18,_6„ -6" 11'-0" 13'-0'. - 1 N/A N _A NOTES: 1. 32" RAFTER SPACING IS ALLOWABLE FOR OPEN LATTICE PATIO COVERS ONLY, 2. FOR SOLID PATIO COVERS (NOT LATTICE) RAFTER SPAN IS LIMITED TO 10'-O" USING THIS STANDARD. LATTICE ROOF BUILT-UP ROOF I HEADERS HEADERS DOUGLAS' FIR NO, 1 DOUGLAS FIR NO, 1 SIZE SPAN SIZE SPAN `I € 4x4'-C_ 4x4 4'-0" ` 4x6 8'-C" 4x6 E'-0" 4x8 111-0' 4x8 -5.-F 4x10 14'-O" 4x10 10'-0.1 412- _'_17---Q 412_ 12'-0'' I 6x8 14'-0" 6x8 12'--0" 600 17'-0' 6x10 14'- IT R00FING NOTES: A, BUILT-UP, ROLLED ROOF: SLOPE TO DRAIN. B. ROCK ROOF: 3i 12 MAXIMUM PITCH. • PER 2016 CALIFORNIA BUILDING CODE • DESIGNS OTHER THAN THE CITY STANDARD ARE POSSIBLE WITH SITE SPECIFIC ENGINEERING 78495 CALLE TAMPICO - LA QUINTA, CA 92253 - 760-777-7000 NIW1J. LAgUI NTACA,GOV