09-0861 (SFD) Title 24
U I- TITLE 24 REPORT Title 24 Report for: Zucchero Residence Main House 80-825 Via Montecito (Hideaway Lot 54d & 55d) La Quinta, Ca 92253 Project Designer: Design Mind Studio . 75-175 Merle Dr., Suite 200 Palm Desert, Ca 92211 (760) 773-4488 Report Prepared By: Jon Scott . Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 ^'CITY OF L.A QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Job Number: I DATE l BY Date: 11/13/2009 he EnergyPro computer program has been used to perform the calculations summarized in this compliance repot. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 n+ `f " ` F a TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC, System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 9 11 12 15 18 22 EnergyPro 4.4 by Energysoft Job Number: User Number: 6712 , Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Building Type: [J Single Family ❑ Addition Total Conditioned Floor Area: 11/13/2009 oject Title ❑ Multi Family ❑ Existing + Add/Alt Date n/a ft2 Building Front Orientation: (NE) 45 deg Raised Floor Area: Project Address ft2 Fuel Type: Building Permit # Scott Design & Title 24 6,162 ft2 (760) 200-4780 Documentation Author Average Ceiling Height: 11.6 Telephone plan Check/Date EneravPro Complilgce Method Avg. U: 0.65 CA Climate 7pne 15 Climate Zone Field Check/Date Ratio: TDV Standard Proposed Compliance ILDING ZONE (kBtu/sf-yr) Design Design Margin one Name HVAC 1 HVAC 2 HVAC 3 & 4 Space Heating 1.70 2.16 -0.46 Area n[a n/a n/a Space Cooling 60.56 57.40 3.16 Fans 8.59 9.60 -1.01 Domestic Hot Water 4.17 3.81 0.36 Pumps 0.00 0.09 -0.09 Totals 75.02 73.06 1.96 Percent better than Standard: 2.6% Building Type: [J Single Family ❑ Addition Total Conditioned Floor Area: 6,162 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (NE) 45 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 6,162 ft2 Fenestration: Average Ceiling Height: 11.6 ft Area: 1,630 ft2 Avg. U: 0.65 Number of Dwelling Units: 1.00 Ratio: 26.4% Avg. SHGC: 0.45 Number of Stories: 1 ILDING ZONE INFORMATION # of Thermostat Vent one Name HVAC 1 HVAC 2 HVAC 3 & 4 Floor Area Volume 1 7nn7nn 17 nnn 1 109 11 090 3,353 43,589 Units Zone Type Type _028_ Sleeping SPPo- ice_ 0.1g Slee�66 Sleeping, tat 0.54 Living Livin Stg at Hgt. Area n[a n/a n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 1 644 _0 028 R-38 R_n 0 27n n Wall Wnnd 154 0 039 R-38 R-0.0 225 go Wall Wood 190 0 074 R_19 R-0.0 225 gQ Wall Wnnd 430 n 039 13-38 R -n n 315 An Wall Wood 64 0.039 R_38 R_0 0 455 gn Wall Wood 180 0 069 R_21 R-0 0 45 gn Wall Wnnd 17 n 039 R-38 R -n n 135 gn Wall Wnnd 130 0 069 R_21 R-0 0 135 qn Roof Wood 1 100 �S R_38 R-0.0 270 n Wall Wnnd 70 n o;a 13_38 13-0 0 298i An Wall Wnnd 190 n 069 R-21 R -n n 995 AD Wall Wnnd 278 n 039 R_38 R -n n 315 _An Wall Wood 385 0.039 R_38 R-0.0 45 gn Will Wood 75 0 039 R-38 R_0.0 135 gn Ronf Wood 3,263 0 028 R_38 R-0.0 270 n Wall Wood 186 0 039 13.38 R-0.0 _225 go Wall Wnnd 250 n n69 R_21 R -n n 9 95 An Wall Wnnd 17 n 039 R-38 R -n n 315 gp Wall Wnnd 450 n 069 R_21 R -n n 315 gn Wall Wood 245 0.039 R_38 R-0 0 45 gn Wall Wood 90 0 069 R_21 R-0 0 45 A() Wall Wood 603 _0 03,2 R_38 R-0.0 135 go Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Paae:3 of 27 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R hero Re Title 11/13/2009 Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments J- Skylight Rear (ZI) 9 0 0_660.116-A 0_39 NFRC 270 0_ New Solar Ind ictri -c Skylight Master Suite 2 Skylight Rear (W) 9.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Master Suite 3 Skylight Rear (W) 9.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Master Suite 4 Skylight Rear (W) 9.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Master Suite 5 Skylight Rear (W) 20.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Master Suite 6 Window Rear (SW) 100.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Master Suite L Window Right (NW) 6.0 0_610 116-A 0_46 NFRC 315 90 New Panda Windows _Master Suite 8 Window Right (NW) 6.0 0.610 116-A 0.46 NFRC 315 90 New Panda Windows Master Suite 5 Window Right (NW) 6.0 0_610 116-A 0_46 NFRC 315 90 New Panda Windows Master Suite -M Window Right (NW) 96.0 0_670 116-A 0_46 NFRC 315 90 New Panda Doors _Master Suite 11 Window Right (NW) 6.0 0_610 116-A 0_46 NFRC 315 90 New Panda Windows Master Suite 12 Window Left (SE) 48.0 0.610 116-A 0_46 NFRC 135 90 New Panda Windows Master Suite Aa Window Left (SSE) 100.0 0_670 116-A -0A6 NFRC 135 PiQ New Panda Doors Master Suite 14 Skylight Rear (W) 9.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Bedroom 2 & 3 Office 15 Window Right (NW) 6.0 0.610 116-A 0_46 NFRC 315 90 New Panda Windows Bedroom 2 & 3 Office 16 Window Right (NW) 6.0 0.610 116-A 0_46 NFRC 315 90 New Panda Windows Bedroom 2 & 3 Office 17 Window Right (NW) 6.0 0.610 116-A 0_46 NFRC: 315 90 New Panda Windows Bedroom 2 & 3 Office 18 Window Front (NE) 45.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Bedroom 2 & 3 Office -IR Window Front (NE) 45.0 0_610.116-A 0_46 NFRC 45 90 New Panda Windows Bedroom 2 & 3 Office 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left -En n Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 None 1.00 None 1.00 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 None 1.00 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Type Area Thick. Heat Inside (sf) (in.) Cap. Cond. R -Val. JA IV Reference Condition Status Location/ Comments Concrete, Heavyweight 623 3.50 28 0.98 2 26-A1 New Master Suite / Slab on Grade Concrete, Heavyweight 1,077 3.50 28 0.98 0 26-A1 New Master Suite / Slab on Grade Concrete, Heavyweight 905 3.50 28 0.98 2 26-A1 New Bedroom 2 & 3 Office / Slab on Concrete, Heavyweight 204 3.50 28 0.98 0 26-A1 New om 2 & 3 Office / Slab on Concrete, Heavyweight 2,812 3.50 28 0_98 0 26-A1 New / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 61 None No Insulation 26-A1 New Master Suite Slab Perimeter 97 None No Insulation 26-A1 New Master Suite ab Perimeter 84 None No Insulation 26-A1 New Bedroom 2 & 3 Office Mb Perimeter 33 None No Insulation 26-A1 New Bedroom 2 & 3 Office ab Perimeter 220 None No Insulation 26-A1 New Livina EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 27 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R 11/13/2009 Date True Cond. Location/ # Type Area U-Factorl SHGC2 Azm. Tilt Stat. Glazing Type Comments 2Q Window Front (NF) 6_0 0_610 116-A 0_46 NFRC 45_ _gQ New Panda Windows Bedroom 7 & S Office 21 Window Front (NE) 45.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Bedroom 2 & 3 Office 22 Window Left (SE) 20.0 0.670 116-A 0_46 NFRC 135 90 New Panda Doors Bedroom 2 & 3 Office 23 Window Left (SE) 40.0 0.670 116-A 0_46 NFRC 135 90 New Panda Doors Bedroom 2 & 3 Office 24 Skylight Rear (W) 9.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Living 25 Skylight Rear (W) 9.0 0.660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Living 2-6 Skylight Rear (W) 9.0 0_660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Living 27 Skylight Rear (W) 9.0 0.660 116-A 0.39 NFRC 270 0 New Solar Industries Skylight Living 2a - Skylight Rear (W) 9.0 0_660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight living 22 -Skylight Rear W) 9.0 0_660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight _Living 3Q Skylight Rear (W) 36.0 0_660 116-A 0_39 NFRC 270 0 New Solar Industries Skylight Living 31 Window Rear (SW) 204.3 0.670 116-A 0_46 NFRC 225 90 New Panda Doors Living 22 Window Rear (SW) 90.0 0_670 116-A . 0_46 NFRC 225 -$Q New Panda Doors Living 33 Window Rear (SW) 3.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Living 34 Window Rear (SW) 3.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Living 35 Window Rear (SW) 3.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Living 36 Window Rear (SW) 3.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Living 37 Window Rear (SW) 3.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Living �U Window Rear (SW) 3.0 0_610_116-A _0.46 NFRC 225 90 New Panda Windows Living 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fn Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 Bug Screen 0.76 None 1*5 1.00 None 1.00 26 None 1.00 27 None 1.00 28 None 1.00 29 None 1.00 30 None 1.00 31 Bug Screen 0.76 9.0 22.7 10.0 0.1 10.0 10.0 32 Bug Screen 0.76 33 Bug Screen 0.76 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Concrete, Heavyweight 541 3.50 28 0_98 2 26-A1 New Living / Slab on Grade PERIMETER LOSSES Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Run Initiation Time: 11/13/0910:43:52 Run Code: 1258137832 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:5 of 27 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R 11/13/2009 Date True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 3R Window Right (NW) 30 _ 0_610 116_A 0_46 NERC 315 -9L New Panda Windows Living 40 Window Front (NE) 76.5 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Living 41 Window Front (NE) 40.5 0.670 116-A 0_46 NFRC 45 90 New Panda Doors Living 42 Window Front (NE) 85.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Living 43 Window Front (NE) 3.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Living 44 Window Front (NE) 3.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Living 45 Window Front (NE) 3.0 0_610 116-A 0_46 NFRC 45 90 New Panda Windows Living 46 Window Front (NE) 3.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Living 4Z Window Front (NE)3.0 0.76 _ 0.910 116-A 0_45 NFRC 45 90 New Panda Windows Living 4$ Window Front (NE) 3.0 0_610 116-A 0_46 NFRC 45 90 New Panda Windows Living 49 Window Left (SE) 76.5 0_610 116-A 0_46 NFRC 135 90 New Panda Windows Living 50 Window Left (SE) 47.7 0.670 116-A 0_46 NFRC 135 90 New Panda Doors Living 51 Window Left (SE) 126.0 0_670 116-A 0_46 NFRC 135 -91 New Panda Doors Living 52 Window Left (SE) 3.0 0.610 116-A 0_46 NFRC 135 90 New Panda Windows Living 53 Window Left (SE) 3.0 0.610 116-A 0_46 NFRC 135 90 New Panda Windows Living 54 Window Left (SE) 3.0 0.610 116-A 0_46 NFRC 135 90 New Panda Windows Living 55 Window Left (SE) 3.0 0.610 116-A 0_46 NFRC: 135 90 New Panda Windows Living 56 Window_ Left (SE) 90.0 0.670 116-A 0.46 NFRC 135 90 New Panda Doors Livina 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B INTERIOR AND EXTERIOR SHADING window Overhang Left Fn Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 41 Bug Screen 0.76 Screen 0.76 40Bug Bug Screen 0.76 4 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 9.0 5.3 10.0 0.1 10.0 10.0 51 Bug Screen 0.76 9.0 14.0 10.0 0.1 10.0 10.0 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES R -Val. Insulation Condition Location/ Location JA IV Reference Status Comments i EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:6 of 27 1 . Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R Reside Title AC SYSTEMS 11/13/2009 Date HVAC DISTRIBUTION Location Duct Cooling Location HVAC 1 Ducted Ducted Attic HVAC 2 Ducted Ducted Attic HVAC 3 & 4 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value S-atus Tested? 4.2 New Yes 4.2 NEw Yes 4.2 NEw Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Bradford White EF -100T -150E- Large Gas Recirc/Time+Temp 1 150,000 100 New 0.99 1.01% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) AJd 1/2" Control # HP TVDe In Plenum Outside Buried Irsulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and hof the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual wit:i overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater - Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: Jon Scott Title/Firm: Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC 1 Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC 2 Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC 3 & 4 Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Location Duct Cooling Location HVAC 1 Ducted Ducted Attic HVAC 2 Ducted Ducted Attic HVAC 3 & 4 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value S-atus Tested? 4.2 New Yes 4.2 NEw Yes 4.2 NEw Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Bradford White EF -100T -150E- Large Gas Recirc/Time+Temp 1 150,000 100 New 0.99 1.01% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) AJd 1/2" Control # HP TVDe In Plenum Outside Buried Irsulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and hof the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual wit:i overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater - Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: Jon Scott Title/Firm: Design Mind Studio Title/Firm: Scott Design & Title 24 Address: 75-175 Merle Dr., Suite 200 Address: 77085 Michigan Dr. Palm Desert, Ca 92211 Palm Desert, CA 92211 Telephone: (760) 773-4488 Lic. #: Telephone: 760 200-4780 (signature) (date) (signature) te) Enforcement Agency Name: Title/Firm: Address: Telephone: gnature) (date) I EneravPro 4.4 by EneravSoft User Number: 6712 Job Number: Paae:7 of 27 1 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Title 11/13/2009 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The Roof "R-38 Roof(R.38.2x14.24)" includes a Radiant Barrier. The HVAC System "HVAC 1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas HIGH MASS Design - Thermal Mass: 623 sqft Covered Slab Floor, 3.50" thick at Master Suite HIGH MASS Design - Thermal Mass: 1077 sqft Exposed Slab Floor, 3.50" thick at Master Suite The HVAC System "HVAC 2" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design - Thermal Mass: 905 sqft Covered Slab Floor, 3.50" thick at Bedroom 2 & 3 Office HIGH MASS Design - Thermal Mass: 204 sqft Exposed Slab Floor, 3.50" thick at Bedroom 2 & 3 Office The HVAC System "HVAC 3 & 4" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design - Thermal Mass: 2812 sqft Exposed Slab Floor, 3.50" thick at Living HIGH MASS Design - Thermal Mass: 541 sqft Covered Slab Floor, 3.50" thick at Living HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervsion of a nrmc proviaer using approves testing anaror venncation metnoas. Plan Field he HVAC System "HVAC 1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC 1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 24ACA460/58MVB080" includes credit for a 11.5 EER Condenser. The HVAC System "HVAC 2" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC 2" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 24ACA448/58MVB080" includes credit for a 11.5 EER Condenser. The HVAC System "HVAC 3 & 4" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "HVAC 3 & 4" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 24ACA460/58MVB080" includes credit for a 11.5 EER Condenser. Run Initiation Time: 11/13/09 10:43:52 Run Code: 1258137832 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 27 0 • Mandatory Measures Summary: Residential (Pagel of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (`) below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and Included with &-e ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. § 150(b): Loose fill insulation manufacturer's labeled R -Value: 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ o ❑ ❑ ❑ ❑ ❑ 0 ❑ ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. N ❑ ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ N a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ Q ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El E] ElCF-6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient infiltration ❑ ❑X ❑ (SHGC), and certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or RCCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ N ❑ ❑ ❑X ❑ ❑ N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ JEnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 27 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance super ede the items marked with an asterisk (') below. When this checklist is incorporated into the permit • documents, the features noted shall be considered by all parties as minimum component performance specifications for th; mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • C DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ 0 ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure syste n that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh it tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductbns in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ ® ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH LUMINAIRES OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminailuminaire has factory instaled HID § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy lumiraires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires_ § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires ❑ o ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Artict; 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)B: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Sect on 119(d). EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page. 10of 27 Residential Kitchen Liqhtinq Worksheet WS -5R Title 11/13/2009 Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens_ Luminaire Type High Efficacy? Watts Quantity High Effi:acy Watts Other Watts 60w Surface Mount Incandescent Yes No X 60.0 x 8 = or 480 1 42w Compact Fluorescent Tri /Quad 4 in Yes X1 No 1 46.0 x 4 = 184 or g46w Compact Fluorescent Triple 4 Pin Yes X1 No 1 28.0 x 6 = 168 or 1�2VUw Linear Fluorescent T5 Elec Yes X1 No 1 34.0 x 6 = 204 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or • • Total A: 556 B: 480 COMPLIES IF Az B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Paae:11 of 27 1 ,MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zucchero Residence Main House 11/13/2009 7— STEM NAME FLOOR AREA HVAC 1 1,700 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,360 29,334 106 760 26,622 Supply Fan Heating Coil 2000 cfm 0 102.9 of ROOMS 68.8 of 3,042 2,457 0 0 0 0 0 0 0 Peat 0 79.4 / 63.2 of 79.4 / 63.2 of O 0 3,042 2,457 35 418 106 1 31 537 Carrier 24ACA460/58MVB080 49,210 2,269 75,000 Total Adjusted System Output a9,210 2,269 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 26.0 of Outside Air 68.8 of 68.8 of 104.1 of O Supply Air Ducts 0 cfm Supply Fan Heating Coil 2000 cfm 102.9 of ROOMS 68.8 of 70.0 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peat 110.0 172.5 of Outside Air 79.4 / 63.2 of 79.4 / 63.2 of O 56.3 / 54.8 of Supply Air Ducts 0 cfm Supply Fan Cooling Coil 2000 cfm 57.7 / 55.4 of 42.8% R.H. ROOMS 79.4/63.20F 78.0/62.7OF Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 27 ,HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Zucchero Residence Main House DATE 11/13/2009 STEM NAME HVAC 2 FLOOR AREA 1,109 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible Total Room Loads 765 17,370 347 367 16,506 Return Vented Lighting 0 Return Air Ducts 1,801 1,524 Return Fan 0 0 Ventilation o 0 01 0 0 Supply Fan 0 0 Supply Air Ducts 1,8011 11524 TOTAL SYSTEM LOAD 20,9:73T777;47 19 553 Heating System Output per System 75,000 Total Output (Btuh) 75,000 Output (Btuh/sqft) 67.61 Cooling System Output. per System 48,000 Total Output (Btuh) 48,000 Total Output (Tons) 4.0 Total Output (Btuh/sqft) 43.3 Total Output (sgft/Ton) 277.2 Air System HVAC EQUIPMENT SELECTION CFM per System 1,600 Carrier 24ACA448/58MVB080 39,937 1,760 75,000 75,000 Airflow (cfm) 1,600 Airflow (cfm/sgft) 1.44 Airflow (cfm/Ton) 400.0 Total Adjusted System Output (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK 39,937 1,760 Aug 2 pm Outside Air (%) 0.0 utside Air (cfm/sgft) :.-,values 0.00 Jan 12 amNot above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 69.1°F 69.1°F 113.20F Outside Air O 0cfm Supply Fan Heating Coil 1600 cfm 69.1 of Return Air Ducts Supply Air Ducts 1123°F ROOMS 70.0 OF I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0 / 72.5 of Outside Air 0 cfm 79.1 / 62.9 OF oe 79.1 / 62.9 of 79.1 / 63.0 OF 55.6 / 54.3 of O Supply Fan Cooling Coil 1600 cfm Return Air Ducts Supply Air Ducts 56.7 / 54.7 OF 42.3% R.H. ROOMS 78.0 / 62.6 OF ' 4kw EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 13 0f 27 ,HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zucchero Residence Main House 11/13/2009 STEM NAME FLOOR AREA HVAC 3 & 4 3,353 Number of Systems 2 Heating System Output per System 75,000 Total Output (Btuh) 150,000 OutDut (Btuh/soft) 44.7 Cooling System Output per System .` Total Output (Btuh) 11 Total Output (Tons) Total Output (Btuh/sgft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sqft) Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS 26.0 of 68.9 of 68.9 of Outside Air 0 cfm Supply Fan 4000 cfm 68.9 of NG SYSTEM PSYC 110.0 / 72.5 of Outside Air 0 cfm 79.4/63.1 of 341 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 2,552 55,639 -569 Lj,n 52,769 0 5,769 4,871 0 0 0 0 0 0 0 0 0 5,769 4,871 67,1781 -569 62 511 ,vuv ,000 Carrier 24ACA460/58MVB080 98,736 3,980 150,000 1.19 06.8 o.o Total Adjusted System Output 98,736 3,980 150,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK I Aug 2 pm 7w12 am rstream Temperatures at T . 104.1oF Heating Coil h Return Air Ducts 'I Supply Air Ducts 102.9 of ROOMS 70.0 of 79.4 / 63.1 of 79.4 / 63.1 of 56.2 / 54.7 of O.01 Supply Air Ducts Supply Fan Cooling Coil 57.5 / 55.2 of 4000 cfm 42.4% R.H. ROOMS 78.0 / 62.6 of Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Paae:14 of 27 1 4 ROOM LOAD SUMMARY PROJECT NAME Zucchero Residence Main House DATE 11/13/2009 STEM NAME HVAC 1 FLOOR AREA 1,700 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Master Suite Master Suite 1 1,360 29,334 106 1,360 29,33t 106 760 26,622 PAGE TOTAL 1 1,360 29,334 1 106 760 26,622 TOTAL 1 1,360 29,234 106 760 26,622 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 15 of 27 ROAM LOAD SUMMARY EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 16 of 27 PROJECT NAME Zucchero Residence Main House DATE 11/13/2009 41 STEM NAME HVAC 2 FLOOR AREA 1,109 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Bedroom 2 & 3 Office Bedroom 2 & 3 Office 1 765 17.370 347 765 17,37C 347 367 16,506 PAGE TOTAL 1 765 17,70 347 367 16,506 TOTAL 1 765 17,70 347 367 16,506 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 16 of 27 4 ROAM LOAD SUMMARY PROJECT NAME Zucchero Residence Main House DATE 11/13/2009 STEM NAME HVAC 3 & 4 FLOOR AREA 3,353 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living1 Living 2,552 55,639 -569 2,552 55.639 -569 1,505 52,769 PAGE TOTAL 1 2,552 55,639 -569 1,505 52,769 TOTAL 1 2,552 55,639 -569 1,505 52,769 EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page: 17 of 27 ROOM HEATING PEAK LOADS Project Title Date 14 ucchero Residence Main House 11/13/2009 Room Information Desi - n Conditions Room Name Master suite Time of Peak Jan 12 am Floor Area 1,700 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area 1,644.0 9.0 9.0 9.0 9.0 20.0 154.0 100.0 190.0 430.0 6.0 6.0 6.0 96.0 6.0 64.0 17.0 48.0 100.0 perimeter = 61.0 perimeter = 97.0 U -Value AT of Btu/hr 2,025 261 261 261 261 581 264 2,684 619 738 161 161 2,830 161 110 1.288 2.948 1.9591 3,116 nems shown with an asterisk ('rr) denote conduction through an interior surface to another room. Page Total: I 21,822 Infiltration: I1 .00 x 1.064 x 1 700 x 10.00 x 0.362 / 6] x LT = 4 800 chedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 26,622 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 18 of 27 ROOM HEATING PEAK LOADS Project TitleDate ucchero Residence Main House 11/13/2009 Room Information Desicin Conditions Room Name Bedroom 2 & 3 Time of Peak Jan 12 am Floor Area 13'18 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT of Btu/hr 1100.0 X X X X X x X X X X X X X X X X x X x x X x X x X X x X X X X X X X X X X X X 0.0280 X x X X X X X x X X X X X X X X x x x x X X X X X X X X X X X X X X x X X X X 44 = = = = = = = = = = = = = = = = = 1,355 9.0 0.6600 44 261 70.0 0.0390 44 120 190.0 0.0690 44 577 278.0 0.0390 44 477 6.0 0.6100 44 161 6.0 0.6100 44 161 6.0 0.6100 44 161 385.0 0,0390 44 661 45.0 0.6100 44 1.208 45.0 0.6100 44=1 208 6.0 0.6100 44 161 45.0 0.6100 44 1,208 75.0 0.0390 44= 129 20.0 0.6700 44=590 40.0 0.6700 44 1,179 perimeter - 07300 44= perimeter = 33.0 0.7300 44 1,060 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 13 374 Infiltration: r 1.001 X 1.064 X 1 109 X 10.00 X 0.362 / 60] x 44 = 3 131 schedule Air Sensible Area Ceiling Height ACH -,�T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,506 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:19 of 27 ROOM HEATING PEAK LOADS oject Title urrhPrn Ri-Ridpnrp Main Hnimim 11 /1 yonna Room Information Desicin Conditions Room Name Living Time of Peak Jan 12 am Floor Area 3,353 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70°F Conduction Area 3,263.0 9.0 9.0 9.0 9.0 9.0 9.0 36.0 185.7 204.3 90.0 3.0 3.0 3.0 3.0 3.0 3.0 250.0 17.0 3.0 450.0 245.0 76.5 40.5 85.1 3.0 3.0 3.0 3.0 3.0 90.0 602.8 76.5 47.7 126.0 3.0 3.0 3.0 U -Value AT OF Btu/hr 4,020 261 261 261 261 261 261 1,045 319 6.023 81 81 81 A 81 29 81 420 2,053 1,194 2281 81 81 81 Al 81 273 1,034 2,053 1,406 3,714 81 81 Items shown with an asterisk (•) denote conduction through an interior surface to another room. Page Total: 33,502 Infiltration: 1.001 x 1.064 x 3 353 x 13.00 x 0.278 / 6] x 0 = 9 468 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 52,769 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 20 of 27 ROOM HEATING PEAK LOADS Conduction Area U -Value AT of Btu/hr 3.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.6100 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 90.0 0.6700 perimeter = 220.0 0.7300 81 2,653 7,066 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 9 800 Infiltration: 1.001 x 1.064 x 3 353 x 13.00 x 0.278 / 6] x 44 = 9 468 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 52,769 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 21 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY • Opaque Surfaces Orientation Area LI -Factor CLTD 1 etrr/hr R-38 Roof R.38.2x14.24 R-38 Wall .38.2x12.16 R-19 Wall .19.24.16 R-38 Wall .38.2x12.16 R-38 Wall W.38.2xl2.16 R-21 Wall R-38 Wall (W.38.2xl2.16) R-21 Wall 1,644.0 x X X X X x x X x X X X 0.0194 X X X X X X X X x X X X 56.0 154.0 0.0390 31.0 190.0 0.0740 31.0 430.0 0.0390 30.2 64.0 0.0390 29.0 180.0 0.0690 29.0 17.0 0.0390 31.0 130.0 0.0690 31.0 28.0 80.8 SW 0.0 29.3 39.9 NW 0.0 29.3 44.1 NW 0.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Skylight 1 Skylight 2 Skylight 3 Skylight 4 Skylight 5 1K 6 111 (7) 112 (8) 113(g) 1M 10 Internal Gain Occupants 4 E ui ment 1 Nage I otal Orientation 107.71 x Shaded Area X X X X X X x x x x X GLF + + + + + + + + + + + Unshaded Area 9.0 X 9.0 X 9.0 X 9.0 x 20.0 X 100.0 x 6.0 X 6.0 X 6.0 X 96.0 X X GLF (Sky) 0.0 28.0 80.8 (Sky) 0.0 28.0 80.8 (Sky) 0.0 28.0 80.8 (Sky) 0.0 28.0 80.8 (Sky) 0.0 28.0 80.8 SW 0.0 29.3 39.9 NW 0.0 29.3 44.1 NW 0.0 29.3 44.1 NW 0.0 29.3 44. NW 0.0 30.4 45.2 Page Total 1,785 186 436 507 72 360 21 278 3,6451 Btu/hr Btu/hr Occupants x 230 Btuh/occ. = 920 Dwelling Units X 1,6001 Btuh 1 1,6001 Infiltration: 1.064 x 0.86 x 107.71 x = 3.2411 Air Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,3341 Latent Gain Btu/hr Occu ants F 41 Occupants X 200 Btuh/oCC. = 800 Infiltration: 4 771 x 0.86 X 107.71 X 0.00158 = 694 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 106 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 22 of 27 -771 RESIDENTIAL ROOM COOLING LOAD SUMMARY Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) x Fenestration x 114 11 • 110 12 1K (13) x 107 71 X ELA x x GLF x x GLF x x NW x x 44.1 x x 0.0 x x 1,914 x x 30.4 x x x x x x x x I x Page Total Orientation 107 71 X ELA Shaded Area X X X X X X X X X X X GLF + + + + + + + + + + + Unshaded Area 6.0 X 48.0 X 100.0 X X X X X X X X X GLF = = = = = Btu/hr NW 0.0 29.3 44.1 264 SE 0.0 29.3 39.9 1,914 SE 0.0 30.4 41.0 4,101 Page Total 1 6,2801 Internal Gain 107 71 X ELA Btu/hr Occu ants Occupants X 230 Btuh/occ. = 920 E ui ment 1 Dwellinq Units X 1,600 Btuh = 1,600 Infiltration: 1.064 X 0.86 X Air Sensible CFM 107 71 X ELA = &T 3.2411 TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29 334 Latent Gain Btu/hr Occu ants 0 Occupants x 200 Btuh/occ. = 800 Infiltration: 4771 X 0.86 'x 107.71 X F -694 Air Latent CFM ELA pW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 106 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 23 of 27 r L I RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title ucchero Residence Main House R-38 Wall Date 11/13/2009 Room Information Design Conditions Room Name: Bedroom 2 8r 3 Office Outdoor Dry Bulb Temperature: 111OF Floor Area: 1,109 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F • L opaque Surtaces R-38 Roof R.38.2x14.24 R-38 Wall W.38.2x12.16 R-21 Wall X X X X X X x x x x x x R-38 Wall W.38.2x12.16 R-38 Wall W.38.2x12.16 R-38 Wall W.38.2x12.16 70.0 0.0390 31.0 SW 190.0 0.0690 31.0 NW 278.0 0.0390 30.2 NE Orientation Area X X X X X X x X x x x x U -Factor X X X X X X x x x x x x CLTD 1 W 1,100.0 0.0194 56.0 SW 70.0 0.0390 31.0 SW 190.0 0.0690 31.0 NW 278.0 0.0390 30.2 NE 385.0 0.0390 29.0 SE 75.0 0.0390 31.0 29.3 44.1 NE 0.0 29.3 44.1 NE 0.0 29.3 44.1 SE 0.0 30.4 41. SE 0.0 30.4 41.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Skylight 14 115 15 116 16 117 17 118 18 119 19 120 20 121 21 1 R 22 1R 23 Internal Gain Occupants 4 E ui ment 1 -age I oral Orientation Shaded Area x X x x x x x x X GLF + + + + + + + + + Unsihaded Area 9.0 x 6.04 X 6.0X 6.0X 45.01 X 45.0 X 6.0 X 45.0 X 20. ' x 40. x i Ix GLF (Sky) 0.0 28.0 80.8 NW 0.0 29.3 44.1 NW 0.0x 29.3+ 44.1 NW 0.0x 29.3+ 44.1 NE 0.0 29.3 44.1 NE 0.0 29.3 44.1 NE 0.0 29.3 44.1 NE 0.0 29.3 44.1 SE 0.0 30.4 41. SE 0.0 30.4 41.0 Page Total Btu/hr 1,194 85 406 328 435 91 2 539 Btu/hr Btu/hr Occupants X 230 Btuh/occ. = 920 Dwelling Units X 1,6001 Btuh = 1,60 Infiltration: 1.064 x 0.86 x 70.27 x = 2114 Air Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 17.3 Latent Gain Btu/hr Occu ants 0 Occupants x 200 Btuh/OCC. = 800 Infiltration: 4 771 x 0.86 x 70.27 x -0.00158 = 453 Air Latent CFM ELA n w TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 347 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 24 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY • Opaque Surfaces Orientation Area LI -Factor CLTD t Rtri/hr R-38 Roof R.38.2x14.24 R-38 Wall .38.2x12.16 R-21 Wall R-38 Wall W.38.2x12.16 R-21 Wall R-38 Wall W.38.2x12.16 R-21 Wall R-38 Wall (W.38.2x12.16) 3,263.0 185.7 250.0 17.0 450.0 245.0 90.0 602.8 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Skylight 24 Skylight 25 Skylight 26 Skylight 27 Skvliciht 28 Skylight 29 Skylight 30 1G 31 1J 32 410 33 x 0.0194 X x 0.0390 X x 0.0690 X x 0.0390 X x 0.0690 X x 0.0390 X x 0.0690 X x 0.0390 X X 0.0 X x (Sky) x X 80.8 x X 28.0 X 56.0 31.0 31.0 30.2 30.2 29.0 29.0 31.0 `'age Total Orientation Btu/hr Shaded Area x x X X x X x x X GLF + + + + + + + + + I Unshaded Area E90x 9.0x 9.04 X 9.0 X 9.0 x 36.01 X O.a x 90.0 x 3.0 X x GLF (Sky) 0.0x 28.0+9.0x 80.8 (Sky) 0.0 28.0 80.8 S 0.0X 28.0+ 80.8 (Sky) 0.0 28.0 80.8 Sk 0.0 28.0 80.8 (Sky) 0.0 28.0 80.8 (Sky) 0.0 28.0 80.8 SW 204.3 30.4 41.0 0.0 30.4 41. PSWW 0.0 29.3 39.9 Page Total 3,542 225 535 20 939 277 180 729 6 446 Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/OCC. = 920 E ui ment 1 Dwelling Units X 1 600 BtUh = 1 600 Infiltration: 1.064 X 0.86 x 212.45 X 0 = 6.3931 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 55 639 Latent Gain Btu/hr Occu ants Occupants x 200 Btuh/occ. = 800 Infiltration: 4 77 x 0.86 x 212.45 x 0.00158 = -1 369 Air Latent CFM ELA n w • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -569 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:25 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date ucchero Residence Main House 111/13/2009 Room Information Desi n Conditions Room Name: Living Outdoor Dry Bulb Temperature: 111OF Floor Area: 3,353 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 411 34 412 35 413 36 414 37 415 38 416 39 122 40 1A 41 100 42 400 43 -age I otal Orientation x x x x x x x x x x x x X x x x X x x x x x x x x x x x x + + + + + = = = = = = = = = = = = GLF = _ _ = SW 0.0X 29.3+ 39.9= SW 0.0X 29.3+ 39.9= SW 0.0x 29.3+ 39.9= SW 0.0x 29.3+ 39.9= SW 0.0 29.3 39.9 NW 0.0x 29.3+ 44.1= NE 0.0 29.3 44. NE 0.0 30.4 45.2 NE 0.0 29.3 44. NE 0.0X 29.3+ Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 411 34 412 35 413 36 414 37 415 38 416 39 122 40 1A 41 100 42 400 43 -age I otal Orientation Shaded Area X x x x X GLF + + + + + Unsthaded Area 3.0X 3.0X 3.0X 3.0X 3.0- X 3.0X 76.5 X 40.5 X 85.0, X ::::I X X Page GLF = _ _ = SW 0.0X 29.3+ 39.9= SW 0.0X 29.3+ 39.9= SW 0.0x 29.3+ 39.9= SW 0.0x 29.3+ 39.9= SW 0.0 29.3 39.9 NW 0.0x 29.3+ 44.1= NE 0.0 29.3 44. NE 0.0 30.4 45.2 NE 0.0 29.3 44. NE 0.0X 29.3+ Total Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/occ. = 920 E ui ment Dwelling Units X 1 1,6001 Btuh 1 1,6001 Infiltration: 1.064 x 0.86 x 212.45 x 0 = 6.3Q-4 Air Sensible CFM ELA ZST. TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 55,6391 Latent Gain Btu/hr Occupants Occupants X I 200 Btuh/occ. = 800 Infiltration: 4 771 X 0.86 x 212.45 X 1 -1,3691 Air Latent ' CFM ELA n w iTOTAL HOURLY LATENT HEAT GAIN FOR ROOM -569 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 26 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY • ue 5urtaces Orientation Area U -Factor CLTD 1 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 401 44 402 45 403 46 404 47 405 48 123 49 1E 50 1F 51 406 52 407 53 rage I otal Orientation X x x x x x x x x x x x X x X X x X x x x x x x x x x x x x + + + + + + = = = = = = = = = = = = GLF = = = = = _ = NE 0.0x 29.3+ 44. NE 0.0x 29.3+ 44.1= NE 0.0 29.3 44.1 NE 0.0x 29.3+ 44.1= NE 0.0x 29.3+ 44.1= SE 0.0 29.3 39.9 SE 47.7 30.4 41.0 SE 126.0 30.4 41.0 SE 0.0 29.3 39. SE O.Ox Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 401 44 402 45 403 46 404 47 405 48 123 49 1E 50 1F 51 406 52 407 53 rage I otal Orientation Shaded Area X x X X x X GLF + + + + + + Unshaded Area 3.0x 3.0X 3.0- X 3.0X 3.0X 76.5 X 0.0 X 0.0 x 3. X 3. X X Page GLF = = = = = _ = NE 0.0x 29.3+ 44. NE 0.0x 29.3+ 44.1= NE 0.0 29.3 44.1 NE 0.0x 29.3+ 44.1= NE 0.0x 29.3+ 44.1= SE 0.0 29.3 39.9 SE 47.7 30.4 41.0 SE 126.0 30.4 41.0 SE 0.0 29.3 39. SE O.Ox 29.3+ Total Btu/hr 0 Btu/hr Internal Gain Btu/hr Occupants 4 Occupants X 230 Btuh/oCC. = 920 E ui ment 1 Dwelling Units X 1,6001 Btuh = 1,600 Infiltration: 1.064 X 0.86 X 212.45 X = 6 393 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 55,6391 Latent Gain Btu/hr Occu ants 0 Occupants X 200 Btuh/oCC. = 800 Infiltration: 4 771 X 0.86 x 212.45 X 0.00158 = -1 369 Air Latent CFM ELA &W. TOTAL HOURLY LATENT HEAT GAIN FOR ROOM -569 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 27 of 27 TITLE 24 REPORT Title 24 Report for: Zucchero Residence Theater 80-825 Via Montecito (Hideaway Lot 54d & 55d) La Quinta, Ca 92253 Project Designer: Design Mind Studio 75-175 Merle Dr., Suite 200 Palm Desert, Ca 92211 (760) 773-4488 Report Prepared By: Jon Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 11/13/2009 ,IlKhe EnergyPro computer program has been used to perform the calculations summarized in this compliance repo t. This program has approval and is thorized by the California Energy Commission for use with both the.Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 I- TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 HVAC System Heating and Cooling Loads Summary 9 Room Load Summary 10 Room Heating Peak Loads 11 Room Cooling Peak Loads 12 EnergyPro 4.4 by EnergySoR Job Number: User Number: 6712 1 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R Building Type: [ Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (NE) 45 deg Natural Gas Area: 262 ft 2 Avg. U: 0.65 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Ratio: 19.7% Avg. SHGC: 0.46 Number of Stories: 6UILDING ZONE INFORMATION # of Thermostat ne Name Floor Area Volume Units Zone Type Type HVAC 5 1-43 13,130 1 on I iyjng I ivingiat OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wnnd X333 0098 R_38 R_p n 995 0 Wall Wood 165 0039 R_38 R_0_0 _225 go Wall Wood 258 0 069 R_91 R-0.0 225 gQ Wall Wnnd 216 n 039 —R-38 R_Q o 115 an Door None 24 1 450 None R-0 0 315 g0 Wall Wood 60 0 069 R_21 R-0 0 315 90 Wall Wond 475 n n39 R-38 R-0 0 45 gn Wall Wnnd 70 n n6a R_21 R-0 0 4S An Wall Wood 178 0 039 R_3g R-0.0 135 gn Wall Wood 143 0 069 R_21 R-0.0 13._9Q 1,333 ft2 n/a ft2 0 ft2 1,333 ft2 10.0 ft 1.00 Vent Hgt. Area 2 —n/a Gains Condition Y / N Status JA IV Reference Location / Comments Run Initiation Time: 11/1310910:51:25 Run Code: 1258138285 EneravPro 4.4 by EnerovSoft User Number: 6712 Job Number: Page:3 of 12 11/13/2009 oject Title Date Project Address Building Permit # Design & Title 24 (760) 200-4780 _Scott Telephone plan Check/Date FnergvPra Complilrice Method (;A C;limatP lone 1 Climate Zone 1 Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.02 5.15 -3.12 Space Cooling 71.79 50.79 21.00 Fans 10.23 8.58 1.65 Domestic Hot Water 14.73 0.00 14.73 Pumps 0.00 0.40 -0.40 Totals 98.77 64.92 33.85 Building Type: [ Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition ❑ Existing + Add/Alt (NE) 45 deg Natural Gas Area: 262 ft 2 Avg. U: 0.65 Total Conditioned Floor Area: Existing Floor Area: Raised Floor Area: Slab on Grade Area: Average Ceiling Height: Number of Dwelling Units: Ratio: 19.7% Avg. SHGC: 0.46 Number of Stories: 6UILDING ZONE INFORMATION # of Thermostat ne Name Floor Area Volume Units Zone Type Type HVAC 5 1-43 13,130 1 on I iyjng I ivingiat OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wnnd X333 0098 R_38 R_p n 995 0 Wall Wood 165 0039 R_38 R_0_0 _225 go Wall Wood 258 0 069 R_91 R-0.0 225 gQ Wall Wnnd 216 n 039 —R-38 R_Q o 115 an Door None 24 1 450 None R-0 0 315 g0 Wall Wood 60 0 069 R_21 R-0 0 315 90 Wall Wond 475 n n39 R-38 R-0 0 45 gn Wall Wnnd 70 n n6a R_21 R-0 0 4S An Wall Wood 178 0 039 R_3g R-0.0 135 gn Wall Wood 143 0 069 R_21 R-0.0 13._9Q 1,333 ft2 n/a ft2 0 ft2 1,333 ft2 10.0 ft 1.00 Vent Hgt. Area 2 —n/a Gains Condition Y / N Status JA IV Reference Location / Comments Run Initiation Time: 11/1310910:51:25 Run Code: 1258138285 EneravPro 4.4 by EnerovSoft User Number: 6712 Job Number: Page:3 of 12 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Residen Title ENESTRATION SURFACES 11/13/2009 Date True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 4 Window Rear (SW) 1820 0_670 116_A(l_ 46 NER r _ 225_ An Nett' Panda Doors Theater -Game Ronm 2 Window Right (NW) 40.0 0.610 116-A 0_46 NFRC 315 90 New Panda Windows Theater -Game Room 3 Window Front (NE) 10.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Theater -Game Room 4 Window Front (NE) 10.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Theater -Game Room 5 Window Front (NE) 10.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Theater -Game Room 6 Window Front (NE) 10.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Theater -Game Room L Window Left (SE) 10.0 0=610 116-A 0_46 _NFRC 135 90 New Panda Windows Theater -Game Room 8 Window Left (SE) 10.0 0.610 116-A 0.46 NFRC 135 90 New Panda Windows Theater -Game Room 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 9.0 18.0 10.0 0.1 10.0 10.0 2 Bug Screen 0.76 3 Bug Screen 0.76 40Bug Screen 0.76 Bug Screen 0.76 _ Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Tvpe (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Tvpe Lenqth R -Val. Location JA IV Reference Status Comments Slab Perimeter 132 None No Insulation 26-A1 New Theater -Game Room Run Initiation Time: 11/13/0910:51:25 Run Code: 1258138285 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 12 -Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Th Title AC 5Y5TEM5 11/13/2009 Date: Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC 5 Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Location Heatinq Coolinq Location HVAC 5 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 N•Bw Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Bradford White EF -100T -150E- Large Gas Recirc/Time+Temp 0 150,000 100 New 0.99 1.01% 0.0 - (date) Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP TvDe In Plenum Outside Buried Insulation REMARKS Theater -Game Room COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and F of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Design Mind Studio Address: 75-175 Merle Dr., Suite 200 Palm Desert, Ca 92211 Telephone: (760) 773-4488 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: ate) Documentation Author Name: Jon Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Palm Desert, CA 92211 Telephone: 760 200_-4780 .� (signature) - (date) I EnergvPro 4.4 by EnergvSoft User Number: 6712 Job Number: Paae:5 of 12 1 'Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Title 11/13/2009 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies �aseu do u1e aueyuacy o1 die speciai justincauun anu documentation suomirteo. Plan I Field Multiple Dwelling Units are served by a common water heater. Verify DHW details on Part 3 of this report. The Roof "R-38 Roof(R.38.2x14.24)" includes a Radiant Barrier. The HVAC System "HVAC 5" must meet all CEC Criteria for a Zonally Controlled system servinq only Livina Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supenasion of a HERS provider using approved testing anmor vermcation metnods. Plan Field The=HVACstem "HVAC 5" incorporates HERS verified Duct Leakage. Target leakage is calculated and documerded on the CF -4R. he HVAC System "HVAC 5" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostati: Expansion Valve. The Cooling System "Carrier 24ACA460/58MVB080" includes credit for a 11.5 EER Condenser. Run Initiation Time: 11/13/09 10:51:25 Run Code: 1258138285 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:6 of 12 Mandatory Measures Summary: Residential (PagE- 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this cher-,list is incorporated into the permit • documents, the features noted shall be considered by all parties as minimum component performance specifications for -he mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • • DESCRIPTION Check or Initial applicable boxes or check NA If not applicable and Included with -:he permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ R§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ a ❑ apply to exterior mass walls). ❑ ❑X ❑ *§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑X ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include El El El Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:7 of 12 0 • Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checHist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for tke mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, ,304, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh -or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. and have an output frequency no less than 20 kHz. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy lumiraires, retardant and provides shielding from solar radiation that can cause degradation of the material. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ 7. Flexible ducts cannot have porous inner cores. ❑ ® ❑ § 114: Pool and Spa Heating Systems and Equipment § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 2. System is installed with: ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ © ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑X ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electrIz and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ © ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determir ed ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy lumiraires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility room=_ shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled ❑ ❑X ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Articib 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Sect'nn 119(d). EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 12 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zucchero Residence Theater 11/13/2009 STEM NAME FLOOR AREA HVAC 5 1,333 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING DEAK I COIL HTG. PEAK CFM I Sensible _atent I CFM I Sensible 23,1:131—:::256 26::08:9] Carrier 24ACA460/58MVB080 48,491 2,894 75,000 Total Adjusted System Output 48,491 2,894 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12m EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak' 26.0°F 69.0°F 69.0°F 104.3°F O Supply Air Ducts Out Air 0 cfm Supply Fan Heating Coil 103.3 OF 2000 cfm ROOMS 69.0 OF 70.0 °F 110.0 / 72.5 OF Outside Air 0 cfm 78.9/63.1°F 78.9 / 63.1 OF Supply Far 2000 cfm h Return Air Ducts `; at 7RQ/R'110F = 5R7/FAR°F C« Supply Air Ducts Cooling Coil 57.1 / 55.1 of 42.9% R.H. ROOMS 78.0 / 62.8 of Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Paae:9 of 12 I i r 4 JR00M LOAD SUMMARY ::1 PROJECT NAME Zucchero Residence Theater DATE 11/13/2009 STEM NAME HVAC 5 FLOOR AREA 1,333 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Theater -Game Room Theater -Game Romm 1 860 19,143 256 860 19.14-3 256 621 22,023 PAGE TOTAL 1 860 19,143 256 621 22,023 TOTAL 1 860 19,143 256 621 22,023 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 12 ROOM HEATING PEAK LOADS oject Title I irrharn Raeirianca Thaafnr14 11111) Mn Date Room Information Design Conditions Room Name Theater -Game Time of Peak Jan 12 am Floor Area R00 Outdoor Dry Bulb Temperature. 26°F Indoor Dry Bulb Temperature 70°F = = = = = = = = = = = = = = = = = = = = Conduction Area U -Value AT OF Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 18 260 Infiltration: I1 1.001 x 1.064 x 1 333 x 10.00 x 0.362 / 60] x 44 = 3 764 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,023 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 11 of 12 1333.0 X x X x x X X X X X X X X X x x x X X x x X X x x X X X x x x X X X x X X X X 0.0280 X x x X X X X X X X X X x x X X X x X x x X X X X X X X x X X X X X X X x x x 44 = = = = = = = = = = = = = = = = = = = = 1,642 165.0 0.0390 44 283 162.0 0.6700 44 4,776 258.0 0.0690 44 783 216.0 0.0390 44 371 24.0 1.4500 44 1,531 40.0 0.6100 44 1,074 60.0 0.0690 44 182 475.0 0,0390 44 815 10.0 0.6100 44 268 10.0 0.6100 44= 10.0 0.6100 44 268 10.0 0.6100 44 268 70.0 0.0690 44= 213 178.0 0.0390 44= 10.0 0.6100 44 268 10.0 0,6100 44=988 143.0 0.0690 44=434 perimeter = 132.0 0.7300 44 4,240 Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 18 260 Infiltration: I1 1.001 x 1.064 x 1 333 x 10.00 x 0.362 / 60] x 44 = 3 764 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 22,023 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 11 of 12 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project TitleDate ucchero Residence Theater 11/13/2009 Room Information Desicin Conditions Room Name: Theater -Game Romm Outdoor Dry Bulb Temperature. 11 1O Floor Area: 1,333 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 78*FOutdoor Daily Range: 340F Opaque Surfaces Orientation Area LI -Factor CLTD 1 Btu/hr R-38 Roof R.38.2x14.24 R-38 Wall W.38.2x12.16 R-21 Wall R-38 Wall W.38.2x12.16 Solid Wood Door R-21 Wall R-38 Wall (W.38.2x12.16) R-21 Wall R-38 Wall .38.2x12.16 1,333.0 X X X X X X X X X X x X 0.0194 X X X X X X X X X X X X 56.0 = = = = = = = = = = = 165.0 0.0390 31.0 258.0 0.0690 31.0 216.0 0.0390 30.2 24.0 1.4500 30.2 60.0 0.0690 30.2 475.0 0.0390 29.0 70.0 0.0690 29.0 178.0 0.0390 31.0 29.3+ 39.9= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 1D 1 01, 103 (2) 104 (3) 105 (4) 106 (5) 107 (6) 0 Page Total Orientation SW NW NE NE NE NE SE SE Shaded Area X X x X X X GLF + + + + + + UnEhaded Area 0.0, X 40.a X 10.0x 10.0x 10.0X 10.01, x _10.0 x lox x X X X Page GLF = = _ 162.0 30.4 41.0 0.0 29.3 44.1 0.0x 29.3+ 44.1= 0.0x 29.3+ 44.1= 0.0X 29.3+ 44.1= 0.0 29.3 44. 0.0x 29.3+ 39.9= 0.0x 29.3+ 39.9= Total Btu/hr Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/oCC. = 920 P P E ui ment 1 Dwelling Units X 1,600l Btuh = 1,600 Infiltration: 1.osa x o.8s x 6a.a6 x03 = 2,542 Air Sensible CFM ELA �T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,143 Latent Gain Btu/hr Occu ants 0 Occupants X 200 Btuh/oCC. = 800 Infiltration: 4 771 X 0.86 X 84.46 x 0.00158 = 4 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 256 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 12 TITLE 24 REPORT Title 24 Report for: Zucchero Residence Guest House 80-825 Via Montecito (Hideaway Lot 54d & 55d) La Quinta, Ca 92253 Project Designer: Design Mind Studio 75-175 Merle Dr., Suite 200 Palm Desert, Ca 92211 (760) 773-4488 Report Prepared By: Jon Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 11/13/2009 AikThe EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 9 10 11 12 EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 -Certtificate Of Compliance: Residential (Part 1 of 4) CF -1 R oject Title 11/13/2009 Date 90-82.5 Via Mantp-noto (Hideaway I at 54d & 55d) IaQijinta Project Address Build ng Permit # Scott nesian & Title 24 (760) 200-4780 Documentation Author Telephone Plan Check/Date EnergyPrn Compli'Ntice Method CA Climate 7onP 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.26 4.91 -2.65 Space Cooling 73.54 67.13 6.41 Fans 10.48 11.38 -0.90 Domestic Hot Water 14.81 14.30 0.52 Pumps 0.00 0.41 -0.41 Totals 101.09 98.13 2.97 Percent better than Standard: 2.9% I BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: (J Single Family ❑ Addition Total Conditioned Floor Area: 1,322 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: (NE) 45 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 1,322 ft2 Fenestration: Average Ceiling Height: 10.0 ft Area: 496 ft2 Avg. U: 0.66 Number of Dwelling Units: 1.00 Ratio: 37.6% Avg. SHGC: 0.46 Number of Stories: 1 0UILDING ZONE INFORMATION # of Thermostat Vent ne Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC 61322��� X199 1()n Sleeping EleepingStat 2 n/a OPAQUE SURFACES Insulation Act. Gains Condition Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Rnof Wnnd 1 322 0 09R R -IR R-Qn 995 n ® ❑ New 02-Agg G uPct Hnuca Wall Wood 229 0.039 RR_M 13-0 0 995 qQ ® ❑New 09-A13 Guest House Wall Wood 60 0.069 R_21 RR -0.0225 qQ ® ❑New 09-A6 Guest House Wall Wnnd 360 n03g RR_38 R_n n 315 90 ® ❑New 09-A13 Guest Hnuse Wall Wood 257 0.039 R_3g R-0 0 45 go ® ❑New 09-A13 Guest House Wall Wood 110 0 069 R_21 R-0 0 45 qt) ® ❑New 09-A6 Guest House Wall Wnnd 130 n n39 �@-38 R-0 n 135 90 ® ❑New 09-A13 C6uest Hnuse Wall Wnnd 340 n n69 R_91 R_0 0 135 90 ® ❑New 09-A6 GueSt Hnuse ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ F-1 F-1 F-1 F-1 ❑❑ F1 1-1 1-1 F-1 ❑❑ Run Initiation Time: 11113/0910:57:39 Run Code: 1258138659 EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page:3 of 13 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R ucchero Residence Guest House oject Title 11/13/2009 Date FENESTRATION SURFACES True Cond. # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments J- Window Rear (SSW) 72.0 0.670 116-A 0.46 NFRC _225_ qQ New Panda Doors Guest House 2 Window Rear (SW) 30.0 0.610 116-A 0_46 NFRC 225 90 New Panda Windows Guest House 3 Window Right (NW) 72.0 0.670 116-A 0_46 NFRC 315 90 New Panda Doors Guest House 4 Window Right (NW) 96.0 0.670 116-A 0_46 NFRC 315 90 New Panda Doors Guest House 5 Window Right (NW) 72.0 0.670 116-A 0_46 NFRC 315 90 New Panda Doors Guest House 6 Window Front (NE) 24.0 0.670 116-A 0_46 NFRC 45 90 New Panda Doors Guest House Z Window Left (SE) 6.0 0.610 116-A 0.46 NFRC 135 90 New Panda Windows Guest House 8 Window Left (SE) 32.0 0.670 116-A 0_46 NFRC 135 90 New Panda Doors Guest House 6 Window Left (,SE) 27.0 0.670 116-A 0.46 NFRC 135 90 New Panda Doors Guest House JR Window Left (SE) 27.5 0.610 116-A 0.46 NFRC 135 90 New Panda Windows Guest House 1 Window Left (SE) 32.0 0.670 116-A 0_46 NFRC 135 90 New Panda Doors Guest House 12 Window Left (SE) 6.0 0.610 116-A 0_46 NFRC 135 90 New Panda Windows Guest House PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 11613. INTERIOR AND EXTERIOR SHADING Window Overhang # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Left Fin Right Fin Len- Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Buq Screen 0.76 New 3 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 _ Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 Ti- Buq Screen 0.76 12 Buq Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments Insulation PERIMETER LOSSES Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 157 None No Insulation 26-A1 New Guest House Slab Perimeter 47 None No Insulation 26-A1 New Guest House Run Initiation Time: 11/1310910:57:39 Run Code: 1258138659 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 13 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R nce Title AC 5Y5TEM5 11/13/2009 Date Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC 6 Central Furnace 94% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Duct Location Heating Cooling Location HVAC 6 Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4.2 few Yes WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Bradford White MRI 100P6BN Large Gas Recirc/Time+Temp 1 83,000 100 New 0.80 1.01% 0.0 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual wife overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TX%A, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Design Mind Studio Address: 75-175 Merle Dr., Suite 200 Palm Desert, Ca 92211 Telephone: (760) 7734488 Lic. #: (signature) Enforcement Agency Name: Title/Firm: Address: Telephone: gnature) (date) Documentation Author Name: Jon Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. Palm Desert, CA 92211 Telephone: 760 200-4780 c� �•�i (signature) (date) I EnemvPro 4.4 by EnergvSoft User Number: 6712 Job Number: Paae:5 of 13 1 Certificate Of Compliance : Residential (Part4 & 4) CF -IR Title 11/13/2009 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification; and may reject a building or design that otherwise complies uaaeu un am auu4uacy or the speciai jusuncation ana aocumentatron suomiaea. Plan I Field The Roof "R-38 Roof(R.38.2x14.24)" includes a Radiant Barrier. The HVAC System "HVAC 6" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Area a. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a ncr%O pruviaer using appruvea tesung anaIor venncauon metnoas. Plan Field VAC System "HVAC 6" incorporates HERS verified Duct Leakage. Target leakage is calculated and documeried on the CF -4R. Che VAC System "HVAC 6" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostati•; Expansion Valve. The Cooling System "Carrier 24ACA460/58MVB080" includes credit for a 11.5 EER Condenser. Run Initiation Time: 11/13/09 10:57:39 Run Code: 1258138659 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:6 of 13 • • • Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa,:h used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this chec°:list is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for tie mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ❑ ❑ ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures ❑ ❑X ❑ f§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ �§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ Q ❑ apply to exterior mass walls). ❑ ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ ❑X ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: ❑ ❑ ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:7 of 13 • • Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance appro.--h used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for -he mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, ,604, ❑ ❑x ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requiremeres of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mest or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reducions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ® ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ ® ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑ ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ® ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ Q ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ ® ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are electri: and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determin ed ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires- ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controliled ❑ ❑x ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Sectic n 119(d). EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page.8 of 13 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Zucchero Residence Guest House 11/13/2009 STEM NAME FLOOR AREA HVAC 6 _ 1.322 TI Number of Systems 1 Heating System Output per System 75,000 Total Output (Btuh) 75,000 Output (Btuh/sgft) 56.7 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sqft) 44.6 Total Output (sgft/Ton) 26g.g Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.51 Airflow (cfm/Ton) 406.8 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible :Latent CFM Sensible 1,402 30,094 260 851 29,590 0 3,121 2,731 0 0 0 0 0 0 0 0 0 3,121 2,731 36,3315 260 35 052 Carrier 24ACA460/58MVB080 49,158 2,371 75,000 Total Adjusted System Output a9,158 2,371 75,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peaki 26.0 of 68.7 of 68.7 of 104.0 of O Supply Air Ducts Outside Air 0 cfm 102.7 of Supply Fan Heating Coil 2000 cfm ROOMS 68.7 of 70.0 of 0-1..— n:_ n..-,- E I PSYCHROMETRICS (Ai 10.0 / 72.5 of 79.5 / 63.3 of 79.5 / 63.3 of 56.4 / 54.9 of Outside Air O 0 cfm Supply Fan Cooling Coil 2000 cfm 79.5/63.3 of h Return Air Ducts 4 Supply Air Ducts 57.8 / 55.4 of 42.9% R.H. ROOMS 78.0 / 62.8 of EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 13 1 r 4 ROOM LOAD SUMMARY PROJECT NAME Zucchero Residence Guest House DATE 11/13/2009 STEM NAME HVAC 6 FLOOR AREA 1,322 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest House Guest House 1 1,402 30,094 260 1,402 30,094 260 851 29,590 PAGE TOTAL 1 1,4021 30,34 260]1 851 297590 TOTAL 1 1,402 30,094 1 260 851 29,590 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 13 ROOM HEATING PEAK LOADS roject Title Date ucchero Residence Guest House 11/13/2009 Room Information Desi n Conditions Room Name Guest House Time of Peak Jan 12 am Floor Area 1,322 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area 1.322.0 229.0 72.0 30.0 60.0 360.0 72.0 96.0 257.0 24.0 110.0 129.5 6.0 32.0 27.0 32.0 6.0 340.0 pernmeter 157.0 perimeter = 47.0 U -Value AT OF Items shown with an asterisk ('f) denote conduction through an interior surface to another room. Page Total: Infiltration: 1.00 x 1.064 x 1 322 x 10.00 x 0.362 / 6] x 0 rhe, Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM Btu/hr 1,629 393 2,123 805 182 618 2,123 2,830 2,123 441 7081 334 222 161 943 796 738 943 161 1,032 0431 1,510 25 857 = 3 733 EnergyPro 4.4 by Energysoft User Number: 6712 Job Number: Page: 11 of 13 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date ucchero Residence Guest House 11/13/2009 Room Information Desicin Conditions Room Name: Guest House Outdoor Dry Bulb Temperature: 11 1O Floor Area: 1,322 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr • R-38 Roof R.38.2x14.24 R-38 Wall W.38.2xl2.16 R-21 Wall R-38 Wall W.38.2x12.16 R-38 Wall W.38.2x12.16 R-21 Wall R-38 Wall (W.38.2xl2.16) R-21 Wall Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 2H 1 200 (2) 2J 3 2A 4 26 5 2C 6 201 (7) 2D 8 2F 9 202 10 x x x x x X x x x X X X 0.0194 X X X X X X x X X X X X 56.0 = = = = = = = = = 1,435 0.0390 31.0 277 0.0690 31.0 128 0.0390 30.2 424 0.0390 29.0 291 0.0690 29.0 220 0.0390 31.0 157 0.0690 31.0 727 45.2 3,256 NW 0.0 30.4 96.0 45.2 4,34 NW 0.0 30.4 72.0 Page Total 1 3,659 Orientation Shaded Area X X X X X X X X X x GLF + + + + + + + + + + Unshaded Area X X X X X X X X X I X1 GLF = = = = = = = = I Btu/hr SW 0.0 . 30.4 72.0 41.0 2,953 SW 0.0 29.3 30.0 39.9 1,196 NW 0.0 30.4 72.0 45.2 3,256 NW 0.0 30.4 96.0 45.2 4,34 NW 0.0 30.4 72.0 45.2 3,256 NE 0.0 30.4 24.0 45.2 1,085 SE 0.0 29.3 6.0 39.9 239 SE 0.0x 30.4+ 32.0X 41.0= 1,312 SE 0.0 30.4 27.0 41.0 1 107 SE 0.0 29.3 1 27.3 39.9 1 097 I Page Total 1s 843 Internal Gain Btu/hr Occu ants 4 Occupants X 230 Btuh/oCC. = 920 E ui ment 1 Dwelling Units X 1 600 Btuh = 1 600 Infiltration: 1.064 x 0.86 x 83.76 x 0 = 2.5211 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 3010 Latent Gain 0 Occupants Occupants X 200 Btuh/OCC. _ Btu/hr 800 Infiltration: 4 77 x 0.86 x 83.76 x -0.00158 = -540 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 260 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 13 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date ucchero Residence Guest House 11/13/2009 Room Information Design Conditions Room Name: Guest House Outdoor Dry Bulb Temperature: 111OF Floor Area: 1,322 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 78'FOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr 11 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Page Total Orientation x x x x x x x x x x x x x x x x x x X X X X x x x x x x x x x x x x + + + + + + + + + + Unshaded Area X X x X x x X x x X GLF SE 0.0 30.4 32.0 41.0 SE 0.0x 29.3+ 6.0x 39.9 IF Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Page Total Orientation Shaded Area x x x x x x X X X X GLF + + + + + + + + + + Unshaded Area X X x X x x X x x X GLF SE 0.0 30.4 32.0 41.0 SE 0.0x 29.3+ 6.0x 39.9 Page Total Internal Gain Occu ants 4 Occupants X 230 Btuh/occ. _ E ui ment 1 Dwelling Units x 1 1,6001 Btuh Btu/hr 1,312 239 1,5521 Btu/hr 920 1,6001 Infiltration: 1.064 x 0.86 x 83.76 x 0 = 2 521 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,0941 Latent Gain Occu ants 0 Occupants x 200 Btuh/occ. _ Btu/hr 800 Infiltration: 4 771 x 0.86 x 83.76 x 0.00 58 = -540 Air Latent CFM ELA pw TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 260 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 13 of 13 I I TITLE 24 REPORT I Title 24 Report for: Zucchero Residence Exercise -Garage 80-825 Via Montecito (Hideaway Lot 54d & 55d) La Quinta, Ca 92253 Project Designer: Design Mind Studio 75-175 Merle Dr., Suite 200 Palm Desert, Ca 92211 (760) 773-4488 Report Prepared By: Jon Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 11/13/2009 EnergyPro computer program has been used to perform the calculations summarized in this compliance repo t. This program has approval and is orized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 I I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7. 9 10 11 12 EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 'Certificate Of Compliance: Residential (Fart 1 of 4) CF -1 R Building Type: Exercise-Garage11/13/2009 ❑ Addition Date oject Title ❑ Existing + Add/Alt Building Front Orientation: (NE) 45 deg Fuel Type: Slab on Grade Area: Natural Gas Fenestration: Project Address 10.0 Area: Building Permit # Sr esian & Title 24 36.7% Avg. (760) 200-4780 Documentation–Author Telephone Plar. Check/Date EneravPro Complildce Method CA Climate 7onP 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.53 13.79 -10.26 Space Cooling 105.52 69.92 35.60 Fans 15.08 13.29 1.79 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 124.14 97.00 27.13 Percent better than Standard: 21.9% Building Type: [j) Single Family ❑ Addition Existing Floor Area: ❑ Multi Family ❑ Existing + Add/Alt Building Front Orientation: (NE) 45 deg Fuel Type: Slab on Grade Area: Natural Gas Fenestration: Average Ceiling Height: 10.0 Area: 121 ft2 Avg. U: 0.66 Ratio: 36.7% Avg. SHGC: 0.46 *UILDING ZONE INFORMATION ne Name Floor Area HVAr 7 330 Total Conditioned Floor Area: 330 ft2 Existing Floor Area: n/a ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 330 ft2 Average Ceiling Height: 10.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 # of Thermostat Vent Volume Units Zone Type Type Hgt. Area 3 inn i on I Mn9 I MngStat —2 n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 330 0098—B_38—n n 92,r) n Wall Wood 13o 0 069 R-21 R-0.0 _225_90 Wall Wood 174 0 039 R_38 R-0.0 315 gQ Wall Wnnd 105 n n39 R-38 R-0 0 45 An Wall Wood 740 0 069 R_21 R-0 0 135 9Il rte_ Gains Condition Y / N Status JA IV Reference Location / Comments EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:3 of 12 1 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R ucchero Residence Exercise -Garage 11/13/2009 oject Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments I Window Right (NW) 790 0_670 116 -A -DAB NFR(' 315 --qO- New Panda Doors Exercise 2 Window Right (NW) 24.00.670 116-A 0_46 NFRC 315 90 New Panda Doors Exercise 3 Window Front (NE) 25.0 0.610 116-A 0_46 NFRC 45 90 New Panda Windows Exercise 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left -Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Les. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 21 None No Insulation 26-A1 New Exercise Slab Perimeter 32 None No Insulation 26-A1 New Exercise Run Initiation Time: 11/13/09 11:08:59 Run Code: 1258139339 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 12 Certificate Of Compliance: Residential (Fart 3 of 4) CF -1 R 11/13/2009 Dale Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC 7 Split Heat Pump 8.80 HSPF Split Heat Pump 15.5 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC 7 Ducted Ducted Attic 4.2 hew Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP TvDe In Plenum Outside Buried Insulation REMARKS Exercise Room & Garage COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: Jon Scott Title/Firm: Design Mind Studio Title/Firm: Scott Design & Title 24 Address: 75-175 Merle Dr., Suite 200 Address: 77085 Michigan Dr. Palm Desert, Ca 92211 Palm Desert, CA 92211 Telephone: (760) 773-4488 Lic. #: Telephone: 760 200-4780 (signature) (date) (signature) ( te) IF Enforcement Agency Name: Title/Firm: Address: Telephone: gnature) (date) I EnergvPro 4.4 by EnergvSoft User Number: 6712 ,lob Number: Paae:5 of 12 1 Certificate Of Compliance: Residential (Fart 4 of 4) CF -1 R Title 11/13/2009 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies uOaWu vn Lila dueyuday vi uie special Jusuncauon dna uocumen[aaon suominea. Plan Field The Roof "R-38 Roof(R.38.2x14.24)" includes a Radiant Barrier. The HVAC System "HVAC 7" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC 7" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. The HVAC System "HVAC 7" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "Carrier 25HCB524/FV4BNF003 " includes credit for a 13.0 EER Condenser. EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:6 of 12 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the • items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications fo the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. 0 • DESCRIPTION Check or Initial applicable boxes or check NA If not applicable and included witt- the permit application documentation. N/A DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ e§ 150(.): Minimum R-19 in wood ceiling insulation or equivalent LI -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. ❑ ❑X ❑ 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ❑ ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ ❑X ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ 0 ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1506. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑ ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:7 of 12 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*) below. When this checklist is incorporated into the permit • documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or Initial applicable boxes when completed or check N/A if rot ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 60:, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure syetem that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either medh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ ❑X ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually opera.ing dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipnent maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores § 114: Pool and Spa Heating Systems and Equipment i El 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑X ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are elecboc 2. System is installed with: § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ a. At least 36" of pipe between filter and heater for future solar heating. ❑ ® ❑ b. Cover for outdoor pools or outdoor spas. ❑ ® ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑X ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Tabla ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are elecboc and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ® ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 0 ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy lumi iaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaireE. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ Q ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are contra led ❑ 0 ❑ by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming poolstwater features or other Artice 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Secbon 119(d). EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:B of 12 (HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY -71 PROJECT NAME Zucchero Residence Exercise-Garage DATE 11/13/2009 STEM NAME HVAC 7 FLOOR AREA 330 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK I COIL HTG. PEAK CFM Sensiblel Latent I CFM Sensible Total Room Loads 47 10,066 665 483 8,144 Return Vented Lighting 0 Return Air Ducts 1,044 622 Return Fan 0 0 Ventilation 0 0 oil 0 0 Supply Fan 0 0 Supply Air Ducts 1,044 622 TOTAL SYSTEM LOAD 12153 665 9 389 Heating System Output per System 23,600 Total Output (Btuh) 23,600 Output (Btuh/sgft) 71.51 Cooling System Output per System 23,600 Total Output (Btuh) 23,600 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 71.5 Total Output (sgft/Ton) 167.8 Air System HVAC EQUIPMENT SELECTION CFM per System 800 Carrier 25HCB524/FV4BNF003 19,185 1,547 14,740 Airflow (cfm) 800 Airflow (cfm/sgft) 2.42 Airflow (cfm/Ton) 406.8 Total Adjusted System Output 119,185 1,547 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 14,740 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Jan 12 am Note: values above given at ARI conditlons EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Pealo 26.0 of 69.3 OF 86.6 OF 86.6 OF O Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 85.9 of 800 cfm ROOMS 69.3 of 70.0 OF Return Air Ducts ' DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peat 110.0/72.5°F 79.2/63.7°F 56.7/55.2°F 56.7/55.2OF O Supply Air Ducts Outside Air 0 cfm Cooling Coil Supply Fan 57.9 / 55.7 of 800 cfm 44.3% R.H. ROOMS 79.2 / 63.6 of 78.0 / 63.2 of Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 12 4 r L ROOM LOAD SUMMARY PROJECT NAME Zucchero Residence Exercise -Garage DATE 11/13/2009 STEM NAME HVAC 7 FLOOR AREA 330 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Exercise Exercise 1 471 10,066 665 471 10,036 665 483 8 144 PAGE TOTAL 1 471 10,OE6 1 66511 483 87144 TOTAL 1 471 10,OE6 1 665 483 8,144 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 12 ROOM HEATING PEAK LOADS Conduction Area U -Value AT OF Rf i/hr 330.0 x x X x X x x X x X x x x x x x x x x x x x X x x x x x x X x X X x X x x x x 0.0280 x X X x x X X X X X x x X x x x x x x x x x x x x x x X x X X x x x x x x x x 44 = = = = = = = = = = = = = = = = = 407 130.0 0.0690 44 395 174.0 0.0390 44 299 72.0 0.6700 44 2,123 24.0 0.6700 44 708 105.0 0.0390 44 180 25.0 0.6100 44 671 240.0 0.0690 44 729 = 21a 0,7300 44 675 perimeter = 32.0 0.7300 44 1,028 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 7 212 Infiltration: 1.001 x 1.064 x 330 x 10.00 x 0.362 / 6] x 44 = 932 chedule Air Sensible Area Ceiling Height ACH 'ST Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8,144 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 11 of 12