Loading...
FSS2022-0322BUILDING PERMIT DESIGN & DEVELOPMENT DEPARTMENT Qa�fra 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ta CALIFORNIA Permit Type: Fire Sprinkler System - Residential - 13D Owner Permit Number: FSS2022-0322 Property Address: 53821 ROSS AVE APN: 767680044 Legal Description Property Zoning: Valuation: $15,000.00 PHONE (760) 777-7125 WWW.LAQUINTACA.GOV APPLIED DATE: 10/03/2022 ISSUED DATE: 11/02/2023 Doan Construction PO Box 8011, Rancho Sante Fe, CA 92675 Applicant: Stacee Weise 647 CAMINO DE LOS MARES STE 108, San Clemente, CA 92673 Contractor: Stacee Weise / 1016781 647 CAMINO DE LOS MARES STE 108, San Clemente, CA 92673 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.Ieginfo.ca.gov/calaw.htm1. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 4/24/25 11:47 am Page 1 of 4 BUILDING PERMIT Permit Type: Fire Sprinkler System - Residential -13D Permit Number: FSS2022-0322 Property Address: 53821 ROSS AVE application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. Printed: 4/24/25 11:47 am Page 2 of 4 BUILDING PERMIT Permit Type: Fire Sprinkler System - Residential -13D Permit Number: FSS2022-0322 Property Address: 53821 ROSS AVE New Fire Sprinkler System *** Construction Details Type Group Sq Ft Value Invoice No. Fee INV-00002055 Fire - Permit Extensions (Admin Processing) Credit Card Convenience Fee Total for InvoiceINV-00002055 PERMIT-FSS2022-0322 FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED PC TECHNOLOGY ENHANCEMENT FEE FIRE SPRINKLER SYSTEMS - SINGLE FAMILY DETACHED RECORDS MANAGEMENT FEE Total for Invoice PERMIT-FSS2022-0322 Grand Total for Permit Fee Amount Amount Paid $92.00 $92.00 $2.30 $2.30 $94.30 $94.30 $250.00 $250.00 $8.00 $8.00 $333.00 $333.00 $11.00 $11.00 $602.00 $602.00 $696.30 $696.30 Workflow Step / Action Name Action Type Start Date End Date Inspections v.1 10/03/2022 0:00 10/23/2023 0:07 ---------------------------------------------------------------------------------------------------------------------------------------- OVERHEAD ROUGH PIPING v.1 Inspection ---------------------------------------------------------------------------------------------------------------------------------------- OVERHEAD HYRO v.1 Inspection Fire Inspections v.1 11/02/2023 10:20 11/14/2023 14:45 Fire Sprinkler Final 13D v.1 Inspection 11/02/2023 10:20 11/14/2023 14:45 Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. Printed: 4/24/25 11:47 am Page 3 of 4 BUILDING PERMIT Permit Type: Fire Sprinkler System - Residential -13D Permit Number: FSS2022-0322 Property Address: 53821 ROSS AVE A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the buildina official. Printed: 4/24/25 11:47 am Page 4 of 4 CAL FIRE - RIVERSIDE UNIT RIVERSIDE COUNTY FIRE DEPARTMENT �Cv BILL WEISER - FIRE CHIEF OFFICE OF THE FIRE MARSHAL — LA QUINTA 78495 Calle Tampico, La Quinta, CA 92253 • Phone (760) 777-7074 • www.rvcfire.org October 17, 2022 California Fire Protection and Backflow Re: Residential Fire Sprinkler Plan Review — Doan Residence FSS2022-0322 (53821 Ross Ave) The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department - Office of the Fire Marshal personnel and are approved with the following conditions. Permanently marked identification signs shall be attached to all control valves. The following inspections/tests are required to be witnessed by Office of the Fire Marshal Staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. *No jacketed electrical and data wiring shall be in contact with, nor have the potential to contact CPVC piping once insulation is installed. (b) Final inspection The Fire Department approved plans and conditions letter must be at the job site. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 48 hours in advance and may be arranged by calling (760)777-7131. All questions regarding the meaning of these conditions should be referred to the Office of the Fire Marshal staff at (760)777-7074. Rebecca Winscott - Fire Safety Specialist RIVERSIDE COUNTY FIRE PROTECTION PLANNING al1�l.K�ICV RECORD OF INSPECTIONS / PERMIT CARD THIS CARD IS TO REMAIN ON SITE AT ALL TIMES. — ❑Al1FORNIa — INSTALLING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS. SEE NOTES ON REVERSE SIDE. JOB ADDRESS: 53821 Ross Ave PERMIT#: FSS2022-0322 AT ED: 10/17/22 DESCRIPTION: Doan Residence CONTRACTOR: California Fire Protection and Backflow HYDRANT SYSTEM DATE INITIALS SPECIAL SUPPRESSION DATE INITIALS Thrust block pre -pour Door fan test UG rough piping Abort test UG hydro Mechanical shutdown Flush Detector test Final E F Deluge/pre-action SPRINKLER U.G. Final EF Thrust block pre -pour UST/AST TANK UG rough piping Installation UG hydro Removal Flush Emergency shut off Final E F Primary piping FIRE SPRINKLER Secondary piping Weld inspection Dispensers & shear valves Overhead rough piping Final EF Overhead hydro MISC. INSPECTIONS UG flush / OK to connect Spray booths Main drain/inspectors' test Hood/duct extinguishing High pile storage High pile rack storage In -rack sprinklers H.P. vents/access/corridors Hose racks Tract access/hydrant verification Final E F Access & Address verification HOOD EXTINGUISHING OTHER CONST. PERMIT Detection system Function test Gas/electrical shut-off Nozzle model/placement Fire alarm connection Final e F SPRAY BOOTHS FIRE CODE PERMIT(S) Installation Air flow test Mechanical interlock Extinguishing system Fire alarm connection Final EF FIRE ALARM KNOX SYSTEM Rough -wire inspection Building Knox box Function test Gate access Knox box/padlock Duct detectors/velocity BUILDING INSPECTIONS 24 hr. battery test T/I final Sprinkler monitoring Shell final Final E F Final for occupancy FINAL INSPECTION DATE: INSPECTORS SIGNATURE: **WHEN CALLING FOR AN INSPECTION PLEASE HAVE PERMIT NUMBER READY. SEE NOTES ON REVERSE SIDE** 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 INSPECTION NOTES 1. Sway bracing and hangers will be inspected at the time of rough piping inspection. 2. All required hydrostatic pressure tests shall maintain 200 psi for a 2-hour duration. (EX: Residential Fire Sprinkler Systems) 3. Fire sprinkler system remodels: if indicated on plans or this card, a hydrostatic pressure test shall be required. 4. All underground joints and thrusts blocks shall be exposed and readily visible during the hydrostatic test. 5. Contractor shall supply all testing equipment, access and operating instructions at time of test. 6. All systems shall be inspected, tested, and approved by a Fire Inspector before any work is started that may cause the affected system to be covered or hidden. POLICIES ON FIELD INSPECTIONS A. INSPECTION REQUESTS: Inspections are made subject to availability. Please have the permit number available when scheduling inspections. For City of La Quinta inspections call: (760) 777-7131. B. APPROVED PLANS: Shall be kept on the job site at all times that work is in progress. Work shall NOT commence without approved plans. C. INSPECTION REQUESTS: As required by the California Fire Code, the appropriate installing contractor shall be required to schedule the necessary inspections and be present on site for inspections. D. RE -INSPECTIONS: Will be charged against a permit when an inspection has failed, is not ready, the responsible party not on site or where previously noted corrections have not been completed. E. COMMODITIES: Unless otherwise noted on approved plans or letter of conditions, no commodities shall be entered into the structure until clearance has been granted by the Fire Dept and Building Official. F. OCCUPANCY: Buildings shall NOT be occupied by persons other than construction workers until a Final Fire Clearance has been granted by the Fire Dept and a Certificate for Occupancy has been issued by the Building Official. INSPECTION NOTES: THIS CARD IS REQURIED TO BE POSTED AT THE CONSTRUCTION SITE. THIS CARD AND APPROVED PLANS MUST BE AVAILABLE AT THE CONSTRUCTION SITE FOR ALL INSPECTIONS. THIS PERMIT SHALL EXPIRE AND BECOME NULL AND VOID IF THE WORK AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS OR MORE. THIS PERMIT IS FOR FIRE DEPARTMENT APPROVAL ONLY AND DOES NOT INTEND TO ABROGATE MORE RESTRICTIVE REQUIREMENTS OF OTHER AGENCIES HAVING RESPONSIBILITY. 78495 CALLE TAMPICO, LA QUINTA, CA 92253 / 760-777-7000 / INSPECTION HOTLINE: 760-777-7131 CALIFORNIA FIRE PROTECTION AND BACKFLOW CALIFORNIA FIRE PROTECTION & BACKFLOW, INC. 647 CAMINO DE LOS MARES SUITE 108 SAN CLEMENTE, CA 92673 TEL. 949.770.5371 WWW.CAFIREPROTECTION.COM LIC NO. C-16 1016781 To whom it may concern, Please extend my fire sprinkler permit FSS2022-0322 for 53821 ROSS AVE, construction took longer than expected and they are now ready for final inspection. Sincerely, Andrew Weise CEO ------ :2ND FLOOR & SECTION ON SHEET 31 L ------- ------------------------------ ------ ----------------- S2= SPRINKLER HEAD LEGEND ,2= I1— SYMBOL 41DEL 1 SSSIN TYPPE TENP.F,RIFGEK—RN., FINISH ESC Ott. R 1ENG1'! -RES — 11*roTAL � . I S—.1 G RININ—RE 11SIFLUELT 11N11 X 1 111 111INILER1 ME 11111REG 11N 111E %P)�—% - N-1 119­ 1 1,L GG,, _R ONLY SRN_, S_ G, —OWED � E, ED ----- - ---- 10' MAXIMUM Off MY WALL PER DESIGN AREA #2. LVA V Ldlm LF mom 0 W OPEN OPEN TO TO u o 11 ABOVE ABOVE ------- ----- ------- --------- — — — — — — ---- ------------- -------- _____ ---------- o 11 Fn o —E ------------ ----- ----- ------------------------ ----------------------- HE o Main ----------------------------------------------------------------------- G.r., EE ------------- ------------------------------- L -------------------- ------------------------------------------------- --------- APPROVED BY GIST FLOOR PIPING PLAN ... APPROVE. Fire Salary Saecielial D R�W— CALIFORNIA 21 R.. A—.K FIRE PROTECTION AND BACKFLOW L.QW-C.921�3 CONTACT INFO Fire Protwtion & Bac!Gfi- OFFICE :949.770.5371/www.caflreprotection.com S-0--II SECTION A 02ND FLOOR PIPING PLAN y W.,-0 V, � IL "pipolo/ 2 OBSTRUCTION NOTES NFFA 13D NEAT SOURCE NOTE5 NFFA 13D APPROVED xY: APPROVED Flre—ty 8P 1.11.t A— FIRE CALIFORNIA eM1� o �° o Doaox�aco .s.3s21 R.. w co �gs.t sm° ,,, � f O x PROTECTION AND BACKFLOW La QW.b Ca 92253 w o ,o,siao` CONTACT INFO California Fire Protwtion & Backllom W 6Yl Camlao De Los Meree R" OFFICE:949.770.5371/www.cafireprotection.com Q Sea Camenle, Ca 92613 Viking Plastics Features • Sizes Available (Nominal): 3/4" (DN20) through 3" (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Hazen -Williams C Value: 150 BlazeMasteC (F'VC Pipe • Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) • Specifications: Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Pipe meets or exceeds ASTM F442. • Certified by NSF International for potable water services. • CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). • cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved. CPVC PIPE PHYSICAL DATA c uL us LISTED FM NSF Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 15' (4,6 m) length Length Approvals Part Number Inch DIN Inch mm Inch mm Lb. Kg. Feet M 3/4" DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cU NSFFM 34PIPE 1" DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PIPE 1 1/4" DN32 1.660 42,164 1.394 35,408 6.27 2,84 15 4.6 114PIPE 1 1/2" DN40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112PIPE 2" DN50 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 21/2" DN65 2.875 1 73,000 2.423 1 61,500 18.86 1 8,55 15 1 4.6 212PIPE 3" DN80 3.500 88,900 2.950 1 74,900 28.01 1 12,71 15 1 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 10, (3,05 m) length Length Approvals Part Number Inch DIN Inch mm Inch mm Lb. Kg. Feet I M 3/4" DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cU NSFFM 34PIPE10 1" DN25 1.315 33,401 1.101 27,965 2.62 1,19 10 3,05 1PIPE10 1 1/4" DN32 1.660 42,164 1.394 35,408 4.18 1,90 10 3,05 114PIPE10 1 1/2" DN40 1.900 48,260 1.598 40,589 5.48 2,49 10 3,05 112PIPE10 2" DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2PIPE10 21/2" DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 212PIPE10 3" DN80 3.500 88,900 2.950 74,900 18.67 8,47 10 3,05 3PIPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. Blazemaster, is a registered trademark of Lubrizol. Specifications subject to change without notice `Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products Trusted above alITI NIKJM4 Viking Plastics CPVC Pipe Product Specifications BlazeMaster" CPVC Pipe Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the following enhanced listings and approvals: • According to UL Listing • Can be flush at return air plenums • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) • 20' spacing on pendent in lieu of 15' • 18' spacing on sidewall in lieu of 14' • Use with combustible concealed sprinklers • UL Listed attic sprinkler head (to protect the floor below) • UL Listed attic sprinkler head with wet system piping (feed main and ridge installation) New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI -NSF Standard 14 and complies with ANSI -NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @ 65.5°C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer's DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. • Exposed sidewall sprinkler listing for exposed pipe & fittings • 24' extended coverage sidewall sprinkler, 12" drop, 155T sprinkler head • 18' extended coverage sidewall sprinkler, 12" drop, 165T sprinkler head • 16' extended coverage sidewall sprinkler, 12" drop, 175T sprinkler head • 14' standard coverage sidewall sprinkler, 12" drop, 200T sprinkler head Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop -in ceilings • Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer's DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer's installation instructions provided with the pipe. The manufacturer's installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Trusted above alIT" NIKJM4 BlazeMaster® Fire Protection Fittings - STANDARD ELBOWS 5006 45° Elbows FIG. NO. SIZE NET WTABS. INCHES 5006 3/4" 0.06 0.32 SXS 5006 1, 0.12 0.39 SXS 5006 1-1 /4" 0.18 0.48 SXS 5006 1-1/2" 0.36 0.47 SXS 5006 2" 0.54 0.58 SXS 5006 2-1/2" 1.00 0.65 SXS 5006 3" 1.28 0.76 SXS 5007 90' Elbows 5007-R UNIV. NOM. APPROX. DIM. A DIM. B JOINT FIG. NO. SIZE NET WT/LBS. INCHES INCHES 5007 3/4" 0.08 0.56 0.56 SXS r, 5007 1 " 0.14 0.69 0.69 SXS 5007 1-1/4" 0.22 0.91 0.91 SXS 4�A 5007 1-1/2" 0.41 1.06 1.06 SXS 5007 2" 0.60 1.24 1.24 SXS �B 5007 2-1/2" 1.16 1.50 1.50 SXS 5007 3" 1.66 1.81 1.81 SXS 5007-R 1 "x3/4" 0.12 0.61 0.75 SXS BlazeMaster® is a registered trademark of The Lubrizol Corporation. Blazemaster� FIRE SPRINKLER FITTINGS m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 •USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com Review— Do's & Don'ts Do's • Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. • Read and follow the installation instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or firestop materials are compatible with CPVC. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Fallow proper handling procedures. • Use tools specifically designed for use with plastic pipe and fittings. • Use the proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end with a chamfering tool. • Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Make certain no solvent cement is on sprinkler head and adapter threads. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and only at a proper pressure. • Bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16" of the pipe or use a surge arrestor. • Install NIBCO® BlazeMaster CPVC Fire Sprinkler Products in wet systems only. • Use only insulation and/or glycerin and water solutions for freeze protection. • Allow for movement due to expansion and contraction. • Ensure installers have been properly trained per the NIBCO BlazeMaster® CPVC Fire Sprinkler System Installation and Design Manual and renew your training every three years at a minimum. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Don'ts • Do not use edible oils as a gasket lubricant. • Do not use petroleum or solvent -based sealants, lubricants, or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not contaminate the CPVC system with cutting oils or compressor oils. • Do not mix glycerin and water solutions in contaminated containers. • Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to CPVC grooved adapters. • Do not thread or groove CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test with air. • Do not pressure test until recommended cure times are met. • Do not exceed proper pressure for testing. • Do not use ratchet cutters below 50°F. • Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in cold weather without allowing for expansion. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in dry systems. • Do not allow puddling of cement in fittings and pipe. • Do not use dull or broken cutting tool blades when cutting pipe. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS STANDARD FITTINGS ', ', , 5001-G 1-1/4" 4233-012 80160 ti 5035 2" 4220-020 80013 Lu 5001-G 1-1/2" 4233-015 80161 ti 5035 2-1/2" 4220-025 80014 a 5001-G 2" 4233-020 80162 CD 5035 3" 4220-030 80008 a 5001-G 2-1/2" 4233-025 80163 5035-R 1"x3/4"x1"0/4" 4220-131 80015 5001-G 3" 4233-030 80164 5006 3/4" 4217-007 80050 5018 1"0/4" 4237-131 80200 5006 1" 4217-010 80051 5018 1-1/4"x1" 4237-168 80202 5006 1-1/4" 4217-012 80052 5018 1-1/4"x3/4" 4237-167 80201 5006 1-1/2" 4217-015 80053 5018 1-1/2"x1-1/4" 4237-212 80205 5006 2" 4217-020 80054 5018 1-1/2"x1" 4237-211 80204 5006 2-1/2" 4217-025 80055 5018 1-1/2"x3/4" 4237-210 80203 W 5006 3" 4217-030 80056 W 5018 2"x1-1/2" 4237-251 80209 m 5007 3/4" 4206-007 80025 ? 5018 2"x1-1/4" 4237-250 80208 "' 5007 1" 4206-010 80026 x CO) 5018 2"x1" 4237-249 80207 5007 1-1/4" 4206-012 80027 m 5018 2"x3/4" 4237-248 80206 5007 1-1/2" 4206-015 80028 5018 2-1/2"x2" 4237-292 80211 5007 2" 4206-020 80039 5018 2-1/2"x1-1/2" 4237-291 80213 5007 2-1/2" 4206-025 80030 5018 2-1/2"x1-1/4" 4237-290 80214 5007 3" 4206-030 80031 5018 2-1/2"x1" N/A 80215 5007-R 1"0/4" 4206-131 80032 5018 3"x2-1/2" 4237-339 80212 5019-H 3/4" 4253-007 N/A 5018 3"x2" 4237-338 80210 5019-H 1" 4253-010 N/A 5018 3"x1-1/2" N/A N/A 5019-H 1-1/4" 4253-012 N/A 5017 3/4" 4247-007 80100 5019-H 1-1/2" 4253-015 N/A 5017 1" 4247-010 80101 5019-H 2" 4253-020 N/A y 5017 1-1/4" 4247-012 80102 5019-H 2-1/2" 4253-025 N/A a 5017 1-1/2" 4247-015 80103 5019-H 3" 4253-030 N/A 5017 2" 4247-020 80104 H (D 5051-A 3" 4254-030 N/A 5017 2-1/2" 4247-025 80105 a J 5051-2-A 3" 4256-030 N/A 5017 3" 4247-030 80106 " 5051-H 3/4" 4251-007 N/A 5001 3/4" 4229-007 80075 5051-H 1" 4251-010 N/A 5001 1" 4229-010 80076 5051-H 1-1/4" 4251-012 N/A 5001 1-1/4" 4229-012 80077 5051-H 1-1/2" 4251-015 N/A 5001 1-1/2" 4229-015 80078 5051-H 2" 4251-020 N/A y 5001 2" 4229-020 80079 5051-H 2-1/2" 4251-025 N/A CD 2 5001 2-1/2" 4229-025 80080 5051-H 3" N/A N/A Ja 5001 3" 4229-030 80081 5011 3/4" 4201-007 8000 0 5001-R 1"0/4" 4229-131 80220 5011 1" 4201-010 8001 c� 5001-R 1-1/4"x1" 4229-168 N/A 5011 1-1/4" 4201-012 8002 5001-R 1-1/2"x3/4" 4229-210 N/A 5011 1-1/2" 4201-015 8003 5001-R 1-1/2"x1" 4229-211 N/A 5011 2" 4201-020 80004 5001-R 1-1/2"x1-1/4" 4229-212 N/A W Lu 5011 2-1/2" 4201-025 8005 5001-R 2"x1" 4229-249 N/A 5011 3" 4201-030 80006 5001-R 2"x1-1/2" 4229-251 N/A 5011-R 3/4"x3/4"x1" 4201-102 80132 5035 3/4" 4220-007 80009 5011-R 1"x1"0/4" 4201-131 80260 H W 5035 1ill4220-010 80010 5011-R 1"x3/4"x1" 4201-126 80134 N a 5035 1-1/4" 4220-012 80011 cu 5035 1-1/2" 4220-015 80012 BlazeMaster° BlazeMaster® is a registered trademark of The Lubrizol Corporation. FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 m TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH:+1/574.295.3327 • FAX:+1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS THREADED FITTINGS ', , 5011-R 1"0/4"0/4" 4201-125 80133 5003-S-BT 1"x1/2" N/A N/A 5011-R 1-1/4"x1-1/4"x1" 4201-168 80262 5003-BI-BSP 1" N/A N/A 5011-R 1-1/4"x1-1/4"x3/4" 4201-167 80261 5003-BI-BSP 1-1/4" N/A N/A 5011-R 1-1/4"x1"x1-1/4" 4201-159 80137 5003-BI-BSP 1-1/2" N/A N/A 5011 R 1 1/4"x1"x1" 4201 158 80136 y w 5003-BI-BSP 2" N/A N/A 5011-R 1-1/4"x1"0/4" 4201-157 80135 a 5004-BI 3/4" N/A 80157 5011-R 1-1/4"x1-1/4"x1-1/2" 4201-169 80138 a 5004-BI 1" N/A 80158 5011-R 1-1/2"x1-1/2"x1-1/4" 4201-212 80275 5004-BI 1-1/4" N/A N/A 5011-R 1-1/2"xl-1/2"x1" 4201-211 80264 5004-BI 1-1/2" N/A N/A 5011-R 1-1/2"x1-1/2"0/4" 4201-210 80263 5004-BI 2" N/A N/A 5011-R 1-1/2"x1-1/4"x1" 4201-202 80140 5018-S-BI 1"x1/2" 4238-130BR N/A y LLu u 5011-R W 1-1/2"x1-1/4"x3/4" 4201-201 80140 y ~ 5011-R 1-1/2"xl-1/2"x2" 4201-213 N/A W 5035-3-S-BI-S 1"x1"x1/2"x1/2" N/A 80462 5011-R 2"x2"x1-1/2" 4201-251 80274 0 5035-3-S-BI-L 1"xl"x1/2"x1/2" N/A 80463 5011-R 2"x2"x1-1/4" 4201-250 80267 5011-R 2"x2"x1" 4201-249 80266 W 5007-3-S-BI 3/4"x1/2" 4207-101 80199 5011-R 2"x2"x3/4" 4201-248 80265 c 5007 3 S BI 1"x1/2" 4207-130 80198 5011-R 2-1/2"x2-1/2"x2" 4201-292 80276 m 5007-3-S-BI 1"0/4" 4207-131 N/A 5011-R 2-1/2"x2-1/2"xl-1/2" 4201-291 80273 w 5007-3-S-BI 1-1/4"x1/2" 4207-166 N/A 5011-R 2-1/2"x2-1/2"xl-1/4" 4201-290 80272 5011-3-3-S-BI-S 1/2"xl/2"x1" N/A 80460 5011-R 2-1/2"x2-1/2"x1" 4201-289 80271 5011-3-3-S-BI-L 1/2"x1/2"x1" N/A 80459 5011-R 3"x3"x2-1/2" 4201-339 80269 5012-S-BI 1" 4202-010 N/A 5011-R 3"x3"x2" 4201-338 80268 5012-S-BI 3/4"0/4"x1/2" 4202-101 80250 5011-R 3"x3"xl-1/2" 4201-337 80270 5012-R-S-BI 1"x3/4"xl/2" 4202-124 N/A 5033-E 3/4" 4257-007 N/A CO) 5012-S-BI 1"xl"xl/2" 4202-130 80251 y 5033-E 1" 4257-010 N/A Lu Lu 5012-R-S-BI 1"xl/2"x1" 4203-122 N/A Z G 5033-E 1-1/4" 4257-012 N/A 5012 R S BI 1-1/4"x1"x1/2" 4202 156 80256 5033 E 1 1/2" 4257 015 N/A 5012-S-BI 1-1 /4"xl -1 /4"xl /2" 4202-166 80252 5033-E 2" 4257-020 N/A 5012 R-S BI 1-1/2"x1-1/4"x1/2" 4202 199 80257 5012-S-BI 1-1/2"xl-1/2"xl/2" 4202-209 80254 5012-S-BI 2"x2"xl/2" 4202-247 80253 THREADED FITTINGS 5012-R-S-BI 2"xl -1 /2"xl /2" 4202-237 80258 CM NIBCO SPEARS TYCO w --j 450-005 1/2" 4250-005 N/A i SIZE FIG. NO. FIG. NO. a 5003-BI 3/4" 4235-007 80142 5003-BI 1" 4235-010 80145 5003-BI 1-1/4" 4235-012 80146 5003-BI 1-1/2" 4235-015 80147 5003-BI 2" 4235-020 80148 5003-2-BI 3/4" 4278-007 N/A y 5003-2-BI o: 1" 4278-010 N/A a 5003-S-BI 3/4"x1/2" 4235-101 80175E or 80175W c 5003-S-BI 1"x1/2" 4235-130 80176E or80175W a 5003-S-BI 1"0/4" 4235-131 80179 5003-2-S-13I 3/4"x1/2" 4238-101 N/A 5003-2-S-13I 1"A /2" 4238-130 N/A 5003-S-BT 3/4"x1/2" N/A N/A Blazemaster+II BlazeMaster® is a registered trademark of The Lubrizol Corporation. +° FIRE SPRINKLER FIINGJ NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516-4740 • USA • PH:1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com TO THE EXTENT PERMITTED BY LAW, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and country to country. NIBCO° BlazeMaster° Warranty NIBCO INC. LIMITED WARRANTY Applicable to NIBCO INC. CPVC Fire Protection Plastic Fittings NIBCO INC. warrants each NIBCO° BlazeMaster° Fire Protection CPVC plastic fitting to be free from defects in materials and workmanship under normal use and service for a period of ten (10) years from date of purchase. In the event any defect occurs which the owner believes is covered by this warranty, the owner should immediately contact NIBCO Technical Services, either in writing or by telephone at 1.888.446.4226 or 1.574.295.3000. The owner will be instructed to return said product, at the owner's expense, to NIBCO INC., or an authorized representative for inspection. In the event said inspection discloses to the satisfaction of NIBCO INC. that said fitting or valve is defective, a replacement shall be mailed free of charge to the owner, and NIBCO INC. shall further pay the installing contractor the sum of ten ($10.00) dollars to apply on the cost of installation of said replacement fitting. TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY SPECIFICALLY EXCLUDES INCIDENTAL AND CONSEQUENTIAL DAMAGES OF EVERY TYPE AND DESCRIPTION RESULTING FROM ANY CLAIMED DEFECT IN MATERIAL OR WORKMANSHIP, INCLUDING BUT NOT LIMITED TO, PERSONAL INJURIES AND PROPERTY DAMAGES. Some states or countries do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply to you. �__4�4 Skit BlazeMaster is a registered trademark of The Lubrizol Corporation. How to Order State quantity, figure number and size for each valve or TECHNICAL ASSISTANCE fitting you wish to order. See individual catalog pages Engineers, contractors, wholesalers or manufacturers for specific or special product designations. may obtain special or technical assistance from any factory representative of NIBCO. Write, fax or phone. HOW MANY TO ORDER NIBCO® valves and fittings are decimal packed for your convenience in handling, shipping and stock - keeping. Number in master carton varies with item. POLICY ON RETURNS TO FACTORY No NIBCO valves and fittings are to be returned with- out prior written agreement. Transportation must be prepaid. A 20% charge will be made to cover cost of rehandling and reinspection. NIBCO INC. World Headquarters 1516 Middlebury Street Elkhart, IN 46516-4740 USA PH: 1.574.295.3000 or 1.888.446.4226 FAX: 1.574.295.3307 or 1.888.336.4226 To the best of our knowledge, the information contained in this publication is accurate. However, NIBCO does not assume any liability whatsoever for the accuracy or completeness of such information. Final determinations of the suitability of any information or product for the use to be contemplated is the sole responsibility of the user. The manner of that use, and whether there is any infringement of patents, is also the sole responsibility of the user. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 • TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.219.295.3221 • FAX: +1.219.295.3455 www.nibco.com BlazeMaster® Fire Protection Fittings - STANDARD TEES 5011 Tees UNIV. NOM. APPROX. DIM. A DIM. B DIM. C JOINT FIG. NO. NOM. SIZE NET WI/LBS. INCHES INCHES INCHES 5011 3/4" 0.10 0.57 0.57 0.57 SXSXS 44 14 - 5011 ill 0.17 0.69 0.69 0.69 SXSXS C 5011 1-1 /4" 0.28 0.89 0.89 0.89 SXSXS 5011 1-1 /2" 0.58 1.05 1.05 1.05 SXSXS I B 5011 2" 0.82 1.25 1.25 1.25 SXSXS 5011 2-1/2" 1.58 1.53 1.53 1.53 SXSXS 5011 3" 2.14 1.84 1.84 1.84 SXSXS 5011-R 3/4"04"x1" 0.14 0.70 0.70 0.73 SXSXS 5011-R 5011-R 1'x1"0/4" 0.16 0.61 0.61 0.94 SXSXS 5011-R 1"x3/4"xl" 0.20 0.76 0.99 0.78 SXSXS 5011-R 1"0/4"0/4" 0.16 0.60 0.87 0.77 SXSXS 5011-R 1-1/4"xl-1/4"x1" 0.24 0.73 0.73 0.89 SXSXS 5011-R 1-1/4"xl-1/4"04" 0.20 0.60 0.60 0.89 SXSXS C 5011-R 1-1/4"xl"xl-1/4" 0.28 0.88 1.03 0.87 SXSXS 5011-R 1-1/4"xl'x1" 0.24 0.71 0.90 0.89 SXSXS IVB 5011-R 1-1 /4"xl '0/4" 0.20 0.61 0.76 0.89 SXSXS 5011-R 1-1/4"xl-1/4"xl-1/2" 0.44 1.01 1.01 0.88 SXSXS 5011-R 1-1/2"xl-1/2"xl-1/4" 0.46 0.89 0.89 1.04 SXSXS 5011-R 1-1/2"xl-1/2"xl" 0.54 0.77 0.77 0.96 SXSXS 5011-R 1-1/2"xl-1/2"04" 0.50 0.67 0.67 1.04 SXSXS 5011-R 1-1/2"xl-1/4"xl" 0.40 0.72 0.91 1.01 SXSXS 5011-R 1-1/2"xl-1/4"04" 0.36 0.60 0.78 1.02 SXSXS 5011-R 1-1/2"xl-1/2"x2" 0.88 1.30 1.30 1.14 SXSXS 5011-R 2"x2"x1-1/2" 0.86 1.06 1.06 1.37 SXSXS 5011-R 2"x2"x1-1/4" 0.67 1.00 1.00 1.28 SXSXS 5011-R 2"x2"xl" 0.72 0.80 0.80 1.25 SXSXS 5011-R 2"x2"0/4" 0.68 0.70 0.70 1.25 SXSXS 5011-R 2-1/2"x2-1/2'V" 1.32 1.26 1.26 1.53 SXSXS 5011-R 2-1/2"x2-1/2"xl-1/2" 1.21 1.06 1.06 1.53 SXSXS 5011-R 2-1/2"x2-1/2"xl -1 /4" 1.12 0.91 0.91 1.53 SXSXS 5011-R 2-1/2"x2-1/2"x1" 1.05 0.74 0.74 1.53 SXSXS 5011-R 3"xTV-1/2" 1.71 1.53 1.53 1.84 SXSXS 5011-R 3"xTV" 1.56 1.26 1.26 1.84 SXSXS 5011-R 3"x3"xl-1/2" 1.39 1.06 1.06 1.82 SXSXS Note: All NIBCO reducing tees are molded to size, not fabricated. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516-4740 • USA • PH:1.800.234.0227 m TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com Review— Do's & Don'ts Do's • Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. • Read and follow the installation instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or firestop materials are compatible with CPVC. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Fallow proper handling procedures. • Use tools specifically designed for use with plastic pipe and fittings. • Use the proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end with a chamfering tool. • Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Make certain no solvent cement is on sprinkler head and adapter threads. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and only at a proper pressure. • Bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16" of the pipe or use a surge arrestor. • Install NIBCO® BlazeMaster CPVC Fire Sprinkler Products in wet systems only. • Use only insulation and/or glycerin and water solutions for freeze protection. • Allow for movement due to expansion and contraction. • Ensure installers have been properly trained per the NIBCO BlazeMaster® CPVC Fire Sprinkler System Installation and Design Manual and renew your training every three years at a minimum. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Don'ts • Do not use edible oils as a gasket lubricant. • Do not use petroleum or solvent -based sealants, lubricants, or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not contaminate the CPVC system with cutting oils or compressor oils. • Do not mix glycerin and water solutions in contaminated containers. • Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to CPVC grooved adapters. • Do not thread or groove CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test with air. • Do not pressure test until recommended cure times are met. • Do not exceed proper pressure for testing. • Do not use ratchet cutters below 50°F. • Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in cold weather without allowing for expansion. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in dry systems. • Do not allow puddling of cement in fittings and pipe. • Do not use dull or broken cutting tool blades when cutting pipe. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS STANDARD FITTINGS ', ', , 5001-G 1-1/4" 4233-012 80160 ti 5035 2" 4220-020 80013 Lu 5001-G 1-1/2" 4233-015 80161 ti 5035 2-1/2" 4220-025 80014 a 5001-G 2" 4233-020 80162 CD 5035 3" 4220-030 80008 a 5001-G 2-1/2" 4233-025 80163 5035-R 1"x3/4"x1"0/4" 4220-131 80015 5001-G 3" 4233-030 80164 5006 3/4" 4217-007 80050 5018 1"0/4" 4237-131 80200 5006 1" 4217-010 80051 5018 1-1/4"x1" 4237-168 80202 5006 1-1/4" 4217-012 80052 5018 1-1/4"x3/4" 4237-167 80201 5006 1-1/2" 4217-015 80053 5018 1-1/2"x1-1/4" 4237-212 80205 5006 2" 4217-020 80054 5018 1-1/2"x1" 4237-211 80204 5006 2-1/2" 4217-025 80055 5018 1-1/2"x3/4" 4237-210 80203 W 5006 3" 4217-030 80056 W 5018 2"x1-1/2" 4237-251 80209 m 5007 3/4" 4206-007 80025 ? 5018 2"x1-1/4" 4237-250 80208 "' 5007 1" 4206-010 80026 x CO) 5018 2"x1" 4237-249 80207 5007 1-1/4" 4206-012 80027 m 5018 2"x3/4" 4237-248 80206 5007 1-1/2" 4206-015 80028 5018 2-1/2"x2" 4237-292 80211 5007 2" 4206-020 80039 5018 2-1/2"x1-1/2" 4237-291 80213 5007 2-1/2" 4206-025 80030 5018 2-1/2"x1-1/4" 4237-290 80214 5007 3" 4206-030 80031 5018 2-1/2"x1" N/A 80215 5007-R 1"0/4" 4206-131 80032 5018 3"x2-1/2" 4237-339 80212 5019-H 3/4" 4253-007 N/A 5018 3"x2" 4237-338 80210 5019-H 1" 4253-010 N/A 5018 3"x1-1/2" N/A N/A 5019-H 1-1/4" 4253-012 N/A 5017 3/4" 4247-007 80100 5019-H 1-1/2" 4253-015 N/A 5017 1" 4247-010 80101 5019-H 2" 4253-020 N/A y 5017 1-1/4" 4247-012 80102 5019-H 2-1/2" 4253-025 N/A a 5017 1-1/2" 4247-015 80103 5019-H 3" 4253-030 N/A 5017 2" 4247-020 80104 H (D 5051-A 3" 4254-030 N/A 5017 2-1/2" 4247-025 80105 a J 5051-2-A 3" 4256-030 N/A 5017 3" 4247-030 80106 " 5051-H 3/4" 4251-007 N/A 5001 3/4" 4229-007 80075 5051-H 1" 4251-010 N/A 5001 1" 4229-010 80076 5051-H 1-1/4" 4251-012 N/A 5001 1-1/4" 4229-012 80077 5051-H 1-1/2" 4251-015 N/A 5001 1-1/2" 4229-015 80078 5051-H 2" 4251-020 N/A y 5001 2" 4229-020 80079 5051-H 2-1/2" 4251-025 N/A CD 2 5001 2-1/2" 4229-025 80080 5051-H 3" N/A N/A Ja 5001 3" 4229-030 80081 5011 3/4" 4201-007 8000 0 5001-R 1"0/4" 4229-131 80220 5011 1" 4201-010 8001 c� 5001-R 1-1/4"x1" 4229-168 N/A 5011 1-1/4" 4201-012 8002 5001-R 1-1/2"x3/4" 4229-210 N/A 5011 1-1/2" 4201-015 8003 5001-R 1-1/2"x1" 4229-211 N/A 5011 2" 4201-020 80004 5001-R 1-1/2"x1-1/4" 4229-212 N/A W Lu 5011 2-1/2" 4201-025 8005 5001-R 2"x1" 4229-249 N/A 5011 3" 4201-030 80006 5001-R 2"x1-1/2" 4229-251 N/A 5011-R 3/4"x3/4"x1" 4201-102 80132 5035 3/4" 4220-007 80009 5011-R 1"x1"0/4" 4201-131 80260 H W 5035 1ill4220-010 80010 5011-R 1"x3/4"x1" 4201-126 80134 N a 5035 1-1/4" 4220-012 80011 cu 5035 1-1/2" 4220-015 80012 BlazeMaster° BlazeMaster® is a registered trademark of The Lubrizol Corporation. FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 m TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH:+1/574.295.3327 • FAX:+1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS THREADED FITTINGS ', , 5011-R 1"0/4"0/4" 4201-125 80133 5003-S-BT 1"x1/2" N/A N/A 5011-R 1-1/4"x1-1/4"x1" 4201-168 80262 5003-BI-BSP 1" N/A N/A 5011-R 1-1/4"x1-1/4"x3/4" 4201-167 80261 5003-BI-BSP 1-1/4" N/A N/A 5011-R 1-1/4"x1"x1-1/4" 4201-159 80137 5003-BI-BSP 1-1/2" N/A N/A 5011 R 1 1/4"x1"x1" 4201 158 80136 y w 5003-BI-BSP 2" N/A N/A 5011-R 1-1/4"x1"0/4" 4201-157 80135 a 5004-BI 3/4" N/A 80157 5011-R 1-1/4"x1-1/4"x1-1/2" 4201-169 80138 a 5004-BI 1" N/A 80158 5011-R 1-1/2"x1-1/2"x1-1/4" 4201-212 80275 5004-BI 1-1/4" N/A N/A 5011-R 1-1/2"xl-1/2"x1" 4201-211 80264 5004-BI 1-1/2" N/A N/A 5011-R 1-1/2"x1-1/2"0/4" 4201-210 80263 5004-BI 2" N/A N/A 5011-R 1-1/2"x1-1/4"x1" 4201-202 80140 5018-S-BI 1"x1/2" 4238-130BR N/A y LLu u 5011-R W 1-1/2"x1-1/4"x3/4" 4201-201 80140 y ~ 5011-R 1-1/2"xl-1/2"x2" 4201-213 N/A W 5035-3-S-BI-S 1"x1"x1/2"x1/2" N/A 80462 5011-R 2"x2"x1-1/2" 4201-251 80274 0 5035-3-S-BI-L 1"xl"x1/2"x1/2" N/A 80463 5011-R 2"x2"x1-1/4" 4201-250 80267 5011-R 2"x2"x1" 4201-249 80266 W 5007-3-S-BI 3/4"x1/2" 4207-101 80199 5011-R 2"x2"x3/4" 4201-248 80265 c 5007 3 S BI 1"x1/2" 4207-130 80198 5011-R 2-1/2"x2-1/2"x2" 4201-292 80276 m 5007-3-S-BI 1"0/4" 4207-131 N/A 5011-R 2-1/2"x2-1/2"xl-1/2" 4201-291 80273 w 5007-3-S-BI 1-1/4"x1/2" 4207-166 N/A 5011-R 2-1/2"x2-1/2"xl-1/4" 4201-290 80272 5011-3-3-S-BI-S 1/2"xl/2"x1" N/A 80460 5011-R 2-1/2"x2-1/2"x1" 4201-289 80271 5011-3-3-S-BI-L 1/2"x1/2"x1" N/A 80459 5011-R 3"x3"x2-1/2" 4201-339 80269 5012-S-BI 1" 4202-010 N/A 5011-R 3"x3"x2" 4201-338 80268 5012-S-BI 3/4"0/4"x1/2" 4202-101 80250 5011-R 3"x3"xl-1/2" 4201-337 80270 5012-R-S-BI 1"x3/4"xl/2" 4202-124 N/A 5033-E 3/4" 4257-007 N/A CO) 5012-S-BI 1"xl"xl/2" 4202-130 80251 y 5033-E 1" 4257-010 N/A Lu Lu 5012-R-S-BI 1"xl/2"x1" 4203-122 N/A Z G 5033-E 1-1/4" 4257-012 N/A 5012 R S BI 1-1/4"x1"x1/2" 4202 156 80256 5033 E 1 1/2" 4257 015 N/A 5012-S-BI 1-1 /4"xl -1 /4"xl /2" 4202-166 80252 5033-E 2" 4257-020 N/A 5012 R-S BI 1-1/2"x1-1/4"x1/2" 4202 199 80257 5012-S-BI 1-1/2"xl-1/2"xl/2" 4202-209 80254 5012-S-BI 2"x2"xl/2" 4202-247 80253 THREADED FITTINGS 5012-R-S-BI 2"xl -1 /2"xl /2" 4202-237 80258 CM NIBCO SPEARS TYCO w --j 450-005 1/2" 4250-005 N/A i SIZE FIG. NO. FIG. NO. a 5003-BI 3/4" 4235-007 80142 5003-BI 1" 4235-010 80145 5003-BI 1-1/4" 4235-012 80146 5003-BI 1-1/2" 4235-015 80147 5003-BI 2" 4235-020 80148 5003-2-BI 3/4" 4278-007 N/A y 5003-2-BI o: 1" 4278-010 N/A a 5003-S-BI 3/4"x1/2" 4235-101 80175E or 80175W c 5003-S-BI 1"x1/2" 4235-130 80176E or80175W a 5003-S-BI 1"0/4" 4235-131 80179 5003-2-S-13I 3/4"x1/2" 4238-101 N/A 5003-2-S-13I 1"A /2" 4238-130 N/A 5003-S-BT 3/4"x1/2" N/A N/A Blazemaster+II BlazeMaster® is a registered trademark of The Lubrizol Corporation. +° FIRE SPRINKLER FIINGJ NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516-4740 • USA • PH:1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com TO THE EXTENT PERMITTED BY LAW, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and country to country. NIBCO° BlazeMaster° Warranty NIBCO INC. LIMITED WARRANTY Applicable to NIBCO INC. CPVC Fire Protection Plastic Fittings NIBCO INC. warrants each NIBCO° BlazeMaster° Fire Protection CPVC plastic fitting to be free from defects in materials and workmanship under normal use and service for a period of ten (10) years from date of purchase. In the event any defect occurs which the owner believes is covered by this warranty, the owner should immediately contact NIBCO Technical Services, either in writing or by telephone at 1.888.446.4226 or 1.574.295.3000. The owner will be instructed to return said product, at the owner's expense, to NIBCO INC., or an authorized representative for inspection. In the event said inspection discloses to the satisfaction of NIBCO INC. that said fitting or valve is defective, a replacement shall be mailed free of charge to the owner, and NIBCO INC. shall further pay the installing contractor the sum of ten ($10.00) dollars to apply on the cost of installation of said replacement fitting. TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY SPECIFICALLY EXCLUDES INCIDENTAL AND CONSEQUENTIAL DAMAGES OF EVERY TYPE AND DESCRIPTION RESULTING FROM ANY CLAIMED DEFECT IN MATERIAL OR WORKMANSHIP, INCLUDING BUT NOT LIMITED TO, PERSONAL INJURIES AND PROPERTY DAMAGES. Some states or countries do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply to you. �__4�4 Skit BlazeMaster is a registered trademark of The Lubrizol Corporation. How to Order State quantity, figure number and size for each valve or TECHNICAL ASSISTANCE fitting you wish to order. See individual catalog pages Engineers, contractors, wholesalers or manufacturers for specific or special product designations. may obtain special or technical assistance from any factory representative of NIBCO. Write, fax or phone. HOW MANY TO ORDER NIBCO® valves and fittings are decimal packed for your convenience in handling, shipping and stock - keeping. Number in master carton varies with item. POLICY ON RETURNS TO FACTORY No NIBCO valves and fittings are to be returned with- out prior written agreement. Transportation must be prepaid. A 20% charge will be made to cover cost of rehandling and reinspection. NIBCO INC. World Headquarters 1516 Middlebury Street Elkhart, IN 46516-4740 USA PH: 1.574.295.3000 or 1.888.446.4226 FAX: 1.574.295.3307 or 1.888.336.4226 To the best of our knowledge, the information contained in this publication is accurate. However, NIBCO does not assume any liability whatsoever for the accuracy or completeness of such information. Final determinations of the suitability of any information or product for the use to be contemplated is the sole responsibility of the user. The manner of that use, and whether there is any infringement of patents, is also the sole responsibility of the user. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 • TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.219.295.3221 • FAX: +1.219.295.3455 www.nibco.com Viking Plastics Features • Sizes Available (Nominal): 3/4" (DN20) through 3" (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Hazen -Williams C Value: 150 BlazeMasteC (F'VC Pipe • Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) • Specifications: Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Pipe meets or exceeds ASTM F442. • Certified by NSF International for potable water services. • CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). • cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved. CPVC PIPE PHYSICAL DATA c uL us LISTED FM NSF Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 15' (4,6 m) length Length Approvals Part Number Inch DIN Inch mm Inch mm Lb. Kg. Feet M 3/4" DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cU NSFFM 34PIPE 1" DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PIPE 1 1/4" DN32 1.660 42,164 1.394 35,408 6.27 2,84 15 4.6 114PIPE 1 1/2" DN40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112PIPE 2" DN50 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 21/2" DN65 2.875 1 73,000 2.423 1 61,500 18.86 1 8,55 15 1 4.6 212PIPE 3" DN80 3.500 88,900 2.950 1 74,900 28.01 1 12,71 15 1 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 10, (3,05 m) length Length Approvals Part Number Inch DIN Inch mm Inch mm Lb. Kg. Feet I M 3/4" DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cU NSFFM 34PIPE10 1" DN25 1.315 33,401 1.101 27,965 2.62 1,19 10 3,05 1PIPE10 1 1/4" DN32 1.660 42,164 1.394 35,408 4.18 1,90 10 3,05 114PIPE10 1 1/2" DN40 1.900 48,260 1.598 40,589 5.48 2,49 10 3,05 112PIPE10 2" DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2PIPE10 21/2" DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 212PIPE10 3" DN80 3.500 88,900 2.950 74,900 18.67 8,47 10 3,05 3PIPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. Blazemaster, is a registered trademark of Lubrizol. Specifications subject to change without notice `Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products Trusted above alITI NIKJM4 Viking Plastics CPVC Pipe Product Specifications BlazeMaster" CPVC Pipe Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the following enhanced listings and approvals: • According to UL Listing • Can be flush at return air plenums • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) • 20' spacing on pendent in lieu of 15' • 18' spacing on sidewall in lieu of 14' • Use with combustible concealed sprinklers • UL Listed attic sprinkler head (to protect the floor below) • UL Listed attic sprinkler head with wet system piping (feed main and ridge installation) New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI -NSF Standard 14 and complies with ANSI -NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @ 65.5°C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer's DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. • Exposed sidewall sprinkler listing for exposed pipe & fittings • 24' extended coverage sidewall sprinkler, 12" drop, 155T sprinkler head • 18' extended coverage sidewall sprinkler, 12" drop, 165T sprinkler head • 16' extended coverage sidewall sprinkler, 12" drop, 175T sprinkler head • 14' standard coverage sidewall sprinkler, 12" drop, 200T sprinkler head Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop -in ceilings • Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer's DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer's installation instructions provided with the pipe. The manufacturer's installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Trusted above alIT" NIKJM4 BlazeMaster® Fire Protection Fittings - STANDARD ELBOWS 5006 45° Elbows FIG. NO. SIZE NET WTABS. INCHES 5006 3/4" 0.06 0.32 SXS 5006 1, 0.12 0.39 SXS 5006 1-1 /4" 0.18 0.48 SXS 5006 1-1/2" 0.36 0.47 SXS 5006 2" 0.54 0.58 SXS 5006 2-1/2" 1.00 0.65 SXS 5006 3" 1.28 0.76 SXS 5007 90' Elbows 5007-R UNIV. NOM. APPROX. DIM. A DIM. B JOINT FIG. NO. SIZE NET WT/LBS. INCHES INCHES 5007 3/4" 0.08 0.56 0.56 SXS r, 5007 1 " 0.14 0.69 0.69 SXS 5007 1-1/4" 0.22 0.91 0.91 SXS 4�A 5007 1-1/2" 0.41 1.06 1.06 SXS 5007 2" 0.60 1.24 1.24 SXS �B 5007 2-1/2" 1.16 1.50 1.50 SXS 5007 3" 1.66 1.81 1.81 SXS 5007-R 1 "x3/4" 0.12 0.61 0.75 SXS BlazeMaster® is a registered trademark of The Lubrizol Corporation. Blazemaster� FIRE SPRINKLER FITTINGS m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 •USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com Review— Do's & Don'ts Do's • Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. • Read and follow the installation instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or firestop materials are compatible with CPVC. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Fallow proper handling procedures. • Use tools specifically designed for use with plastic pipe and fittings. • Use the proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end with a chamfering tool. • Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Make certain no solvent cement is on sprinkler head and adapter threads. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and only at a proper pressure. • Bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16" of the pipe or use a surge arrestor. • Install NIBCO® BlazeMaster CPVC Fire Sprinkler Products in wet systems only. • Use only insulation and/or glycerin and water solutions for freeze protection. • Allow for movement due to expansion and contraction. • Ensure installers have been properly trained per the NIBCO BlazeMaster® CPVC Fire Sprinkler System Installation and Design Manual and renew your training every three years at a minimum. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Don'ts • Do not use edible oils as a gasket lubricant. • Do not use petroleum or solvent -based sealants, lubricants, or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not contaminate the CPVC system with cutting oils or compressor oils. • Do not mix glycerin and water solutions in contaminated containers. • Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to CPVC grooved adapters. • Do not thread or groove CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test with air. • Do not pressure test until recommended cure times are met. • Do not exceed proper pressure for testing. • Do not use ratchet cutters below 50°F. • Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in cold weather without allowing for expansion. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in dry systems. • Do not allow puddling of cement in fittings and pipe. • Do not use dull or broken cutting tool blades when cutting pipe. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS STANDARD FITTINGS ', ', , 5001-G 1-1/4" 4233-012 80160 ti 5035 2" 4220-020 80013 Lu 5001-G 1-1/2" 4233-015 80161 ti 5035 2-1/2" 4220-025 80014 a 5001-G 2" 4233-020 80162 CD 5035 3" 4220-030 80008 a 5001-G 2-1/2" 4233-025 80163 5035-R 1"x3/4"x1"0/4" 4220-131 80015 5001-G 3" 4233-030 80164 5006 3/4" 4217-007 80050 5018 1"0/4" 4237-131 80200 5006 1" 4217-010 80051 5018 1-1/4"x1" 4237-168 80202 5006 1-1/4" 4217-012 80052 5018 1-1/4"x3/4" 4237-167 80201 5006 1-1/2" 4217-015 80053 5018 1-1/2"x1-1/4" 4237-212 80205 5006 2" 4217-020 80054 5018 1-1/2"x1" 4237-211 80204 5006 2-1/2" 4217-025 80055 5018 1-1/2"x3/4" 4237-210 80203 W 5006 3" 4217-030 80056 W 5018 2"x1-1/2" 4237-251 80209 m 5007 3/4" 4206-007 80025 ? 5018 2"x1-1/4" 4237-250 80208 "' 5007 1" 4206-010 80026 x CO) 5018 2"x1" 4237-249 80207 5007 1-1/4" 4206-012 80027 m 5018 2"x3/4" 4237-248 80206 5007 1-1/2" 4206-015 80028 5018 2-1/2"x2" 4237-292 80211 5007 2" 4206-020 80039 5018 2-1/2"x1-1/2" 4237-291 80213 5007 2-1/2" 4206-025 80030 5018 2-1/2"x1-1/4" 4237-290 80214 5007 3" 4206-030 80031 5018 2-1/2"x1" N/A 80215 5007-R 1"0/4" 4206-131 80032 5018 3"x2-1/2" 4237-339 80212 5019-H 3/4" 4253-007 N/A 5018 3"x2" 4237-338 80210 5019-H 1" 4253-010 N/A 5018 3"x1-1/2" N/A N/A 5019-H 1-1/4" 4253-012 N/A 5017 3/4" 4247-007 80100 5019-H 1-1/2" 4253-015 N/A 5017 1" 4247-010 80101 5019-H 2" 4253-020 N/A y 5017 1-1/4" 4247-012 80102 5019-H 2-1/2" 4253-025 N/A a 5017 1-1/2" 4247-015 80103 5019-H 3" 4253-030 N/A 5017 2" 4247-020 80104 H (D 5051-A 3" 4254-030 N/A 5017 2-1/2" 4247-025 80105 a J 5051-2-A 3" 4256-030 N/A 5017 3" 4247-030 80106 " 5051-H 3/4" 4251-007 N/A 5001 3/4" 4229-007 80075 5051-H 1" 4251-010 N/A 5001 1" 4229-010 80076 5051-H 1-1/4" 4251-012 N/A 5001 1-1/4" 4229-012 80077 5051-H 1-1/2" 4251-015 N/A 5001 1-1/2" 4229-015 80078 5051-H 2" 4251-020 N/A y 5001 2" 4229-020 80079 5051-H 2-1/2" 4251-025 N/A CD 2 5001 2-1/2" 4229-025 80080 5051-H 3" N/A N/A Ja 5001 3" 4229-030 80081 5011 3/4" 4201-007 8000 0 5001-R 1"0/4" 4229-131 80220 5011 1" 4201-010 8001 c� 5001-R 1-1/4"x1" 4229-168 N/A 5011 1-1/4" 4201-012 8002 5001-R 1-1/2"x3/4" 4229-210 N/A 5011 1-1/2" 4201-015 8003 5001-R 1-1/2"x1" 4229-211 N/A 5011 2" 4201-020 80004 5001-R 1-1/2"x1-1/4" 4229-212 N/A W Lu 5011 2-1/2" 4201-025 8005 5001-R 2"x1" 4229-249 N/A 5011 3" 4201-030 80006 5001-R 2"x1-1/2" 4229-251 N/A 5011-R 3/4"x3/4"x1" 4201-102 80132 5035 3/4" 4220-007 80009 5011-R 1"x1"0/4" 4201-131 80260 H W 5035 1ill4220-010 80010 5011-R 1"x3/4"x1" 4201-126 80134 N a 5035 1-1/4" 4220-012 80011 cu 5035 1-1/2" 4220-015 80012 BlazeMaster° BlazeMaster® is a registered trademark of The Lubrizol Corporation. FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 m TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH:+1/574.295.3327 • FAX:+1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS THREADED FITTINGS ', , 5011-R 1"0/4"0/4" 4201-125 80133 5003-S-BT 1"x1/2" N/A N/A 5011-R 1-1/4"x1-1/4"x1" 4201-168 80262 5003-BI-BSP 1" N/A N/A 5011-R 1-1/4"x1-1/4"x3/4" 4201-167 80261 5003-BI-BSP 1-1/4" N/A N/A 5011-R 1-1/4"x1"x1-1/4" 4201-159 80137 5003-BI-BSP 1-1/2" N/A N/A 5011 R 1 1/4"x1"x1" 4201 158 80136 y w 5003-BI-BSP 2" N/A N/A 5011-R 1-1/4"x1"0/4" 4201-157 80135 a 5004-BI 3/4" N/A 80157 5011-R 1-1/4"x1-1/4"x1-1/2" 4201-169 80138 a 5004-BI 1" N/A 80158 5011-R 1-1/2"x1-1/2"x1-1/4" 4201-212 80275 5004-BI 1-1/4" N/A N/A 5011-R 1-1/2"xl-1/2"x1" 4201-211 80264 5004-BI 1-1/2" N/A N/A 5011-R 1-1/2"x1-1/2"0/4" 4201-210 80263 5004-BI 2" N/A N/A 5011-R 1-1/2"x1-1/4"x1" 4201-202 80140 5018-S-BI 1"x1/2" 4238-130BR N/A y LLu u 5011-R W 1-1/2"x1-1/4"x3/4" 4201-201 80140 y ~ 5011-R 1-1/2"xl-1/2"x2" 4201-213 N/A W 5035-3-S-BI-S 1"x1"x1/2"x1/2" N/A 80462 5011-R 2"x2"x1-1/2" 4201-251 80274 0 5035-3-S-BI-L 1"xl"x1/2"x1/2" N/A 80463 5011-R 2"x2"x1-1/4" 4201-250 80267 5011-R 2"x2"x1" 4201-249 80266 W 5007-3-S-BI 3/4"x1/2" 4207-101 80199 5011-R 2"x2"x3/4" 4201-248 80265 c 5007 3 S BI 1"x1/2" 4207-130 80198 5011-R 2-1/2"x2-1/2"x2" 4201-292 80276 m 5007-3-S-BI 1"0/4" 4207-131 N/A 5011-R 2-1/2"x2-1/2"xl-1/2" 4201-291 80273 w 5007-3-S-BI 1-1/4"x1/2" 4207-166 N/A 5011-R 2-1/2"x2-1/2"xl-1/4" 4201-290 80272 5011-3-3-S-BI-S 1/2"xl/2"x1" N/A 80460 5011-R 2-1/2"x2-1/2"x1" 4201-289 80271 5011-3-3-S-BI-L 1/2"x1/2"x1" N/A 80459 5011-R 3"x3"x2-1/2" 4201-339 80269 5012-S-BI 1" 4202-010 N/A 5011-R 3"x3"x2" 4201-338 80268 5012-S-BI 3/4"0/4"x1/2" 4202-101 80250 5011-R 3"x3"xl-1/2" 4201-337 80270 5012-R-S-BI 1"x3/4"xl/2" 4202-124 N/A 5033-E 3/4" 4257-007 N/A CO) 5012-S-BI 1"xl"xl/2" 4202-130 80251 y 5033-E 1" 4257-010 N/A Lu Lu 5012-R-S-BI 1"xl/2"x1" 4203-122 N/A Z G 5033-E 1-1/4" 4257-012 N/A 5012 R S BI 1-1/4"x1"x1/2" 4202 156 80256 5033 E 1 1/2" 4257 015 N/A 5012-S-BI 1-1 /4"xl -1 /4"xl /2" 4202-166 80252 5033-E 2" 4257-020 N/A 5012 R-S BI 1-1/2"x1-1/4"x1/2" 4202 199 80257 5012-S-BI 1-1/2"xl-1/2"xl/2" 4202-209 80254 5012-S-BI 2"x2"xl/2" 4202-247 80253 THREADED FITTINGS 5012-R-S-BI 2"xl -1 /2"xl /2" 4202-237 80258 CM NIBCO SPEARS TYCO w --j 450-005 1/2" 4250-005 N/A i SIZE FIG. NO. FIG. NO. a 5003-BI 3/4" 4235-007 80142 5003-BI 1" 4235-010 80145 5003-BI 1-1/4" 4235-012 80146 5003-BI 1-1/2" 4235-015 80147 5003-BI 2" 4235-020 80148 5003-2-BI 3/4" 4278-007 N/A y 5003-2-BI o: 1" 4278-010 N/A a 5003-S-BI 3/4"x1/2" 4235-101 80175E or 80175W c 5003-S-BI 1"x1/2" 4235-130 80176E or80175W a 5003-S-BI 1"0/4" 4235-131 80179 5003-2-S-13I 3/4"x1/2" 4238-101 N/A 5003-2-S-13I 1"A /2" 4238-130 N/A 5003-S-BT 3/4"x1/2" N/A N/A Blazemaster+II BlazeMaster® is a registered trademark of The Lubrizol Corporation. +° FIRE SPRINKLER FIINGJ NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516-4740 • USA • PH:1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com TO THE EXTENT PERMITTED BY LAW, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and country to country. NIBCO° BlazeMaster° Warranty NIBCO INC. LIMITED WARRANTY Applicable to NIBCO INC. CPVC Fire Protection Plastic Fittings NIBCO INC. warrants each NIBCO° BlazeMaster° Fire Protection CPVC plastic fitting to be free from defects in materials and workmanship under normal use and service for a period of ten (10) years from date of purchase. In the event any defect occurs which the owner believes is covered by this warranty, the owner should immediately contact NIBCO Technical Services, either in writing or by telephone at 1.888.446.4226 or 1.574.295.3000. The owner will be instructed to return said product, at the owner's expense, to NIBCO INC., or an authorized representative for inspection. In the event said inspection discloses to the satisfaction of NIBCO INC. that said fitting or valve is defective, a replacement shall be mailed free of charge to the owner, and NIBCO INC. shall further pay the installing contractor the sum of ten ($10.00) dollars to apply on the cost of installation of said replacement fitting. TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY SPECIFICALLY EXCLUDES INCIDENTAL AND CONSEQUENTIAL DAMAGES OF EVERY TYPE AND DESCRIPTION RESULTING FROM ANY CLAIMED DEFECT IN MATERIAL OR WORKMANSHIP, INCLUDING BUT NOT LIMITED TO, PERSONAL INJURIES AND PROPERTY DAMAGES. Some states or countries do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply to you. �__4�4 Skit BlazeMaster is a registered trademark of The Lubrizol Corporation. How to Order State quantity, figure number and size for each valve or TECHNICAL ASSISTANCE fitting you wish to order. See individual catalog pages Engineers, contractors, wholesalers or manufacturers for specific or special product designations. may obtain special or technical assistance from any factory representative of NIBCO. Write, fax or phone. HOW MANY TO ORDER NIBCO® valves and fittings are decimal packed for your convenience in handling, shipping and stock - keeping. Number in master carton varies with item. POLICY ON RETURNS TO FACTORY No NIBCO valves and fittings are to be returned with- out prior written agreement. Transportation must be prepaid. A 20% charge will be made to cover cost of rehandling and reinspection. NIBCO INC. World Headquarters 1516 Middlebury Street Elkhart, IN 46516-4740 USA PH: 1.574.295.3000 or 1.888.446.4226 FAX: 1.574.295.3307 or 1.888.336.4226 To the best of our knowledge, the information contained in this publication is accurate. However, NIBCO does not assume any liability whatsoever for the accuracy or completeness of such information. Final determinations of the suitability of any information or product for the use to be contemplated is the sole responsibility of the user. The manner of that use, and whether there is any infringement of patents, is also the sole responsibility of the user. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 • TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.219.295.3221 • FAX: +1.219.295.3455 www.nibco.com BlazeMaster® Fire Protection Fittings - STANDARD TEES 5011 Tees UNIV. NOM. APPROX. DIM. A DIM. B DIM. C JOINT FIG. NO. NOM. SIZE NET WI/LBS. INCHES INCHES INCHES 5011 3/4" 0.10 0.57 0.57 0.57 SXSXS 44 14 - 5011 ill 0.17 0.69 0.69 0.69 SXSXS C 5011 1-1 /4" 0.28 0.89 0.89 0.89 SXSXS 5011 1-1 /2" 0.58 1.05 1.05 1.05 SXSXS I B 5011 2" 0.82 1.25 1.25 1.25 SXSXS 5011 2-1/2" 1.58 1.53 1.53 1.53 SXSXS 5011 3" 2.14 1.84 1.84 1.84 SXSXS 5011-R 3/4"04"x1" 0.14 0.70 0.70 0.73 SXSXS 5011-R 5011-R 1'x1"0/4" 0.16 0.61 0.61 0.94 SXSXS 5011-R 1"x3/4"xl" 0.20 0.76 0.99 0.78 SXSXS 5011-R 1"0/4"0/4" 0.16 0.60 0.87 0.77 SXSXS 5011-R 1-1/4"xl-1/4"x1" 0.24 0.73 0.73 0.89 SXSXS 5011-R 1-1/4"xl-1/4"04" 0.20 0.60 0.60 0.89 SXSXS C 5011-R 1-1/4"xl"xl-1/4" 0.28 0.88 1.03 0.87 SXSXS 5011-R 1-1/4"xl'x1" 0.24 0.71 0.90 0.89 SXSXS IVB 5011-R 1-1 /4"xl '0/4" 0.20 0.61 0.76 0.89 SXSXS 5011-R 1-1/4"xl-1/4"xl-1/2" 0.44 1.01 1.01 0.88 SXSXS 5011-R 1-1/2"xl-1/2"xl-1/4" 0.46 0.89 0.89 1.04 SXSXS 5011-R 1-1/2"xl-1/2"xl" 0.54 0.77 0.77 0.96 SXSXS 5011-R 1-1/2"xl-1/2"04" 0.50 0.67 0.67 1.04 SXSXS 5011-R 1-1/2"xl-1/4"xl" 0.40 0.72 0.91 1.01 SXSXS 5011-R 1-1/2"xl-1/4"04" 0.36 0.60 0.78 1.02 SXSXS 5011-R 1-1/2"xl-1/2"x2" 0.88 1.30 1.30 1.14 SXSXS 5011-R 2"x2"x1-1/2" 0.86 1.06 1.06 1.37 SXSXS 5011-R 2"x2"x1-1/4" 0.67 1.00 1.00 1.28 SXSXS 5011-R 2"x2"xl" 0.72 0.80 0.80 1.25 SXSXS 5011-R 2"x2"0/4" 0.68 0.70 0.70 1.25 SXSXS 5011-R 2-1/2"x2-1/2'V" 1.32 1.26 1.26 1.53 SXSXS 5011-R 2-1/2"x2-1/2"xl-1/2" 1.21 1.06 1.06 1.53 SXSXS 5011-R 2-1/2"x2-1/2"xl -1 /4" 1.12 0.91 0.91 1.53 SXSXS 5011-R 2-1/2"x2-1/2"x1" 1.05 0.74 0.74 1.53 SXSXS 5011-R 3"xTV-1/2" 1.71 1.53 1.53 1.84 SXSXS 5011-R 3"xTV" 1.56 1.26 1.26 1.84 SXSXS 5011-R 3"x3"xl-1/2" 1.39 1.06 1.06 1.82 SXSXS Note: All NIBCO reducing tees are molded to size, not fabricated. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516-4740 • USA • PH:1.800.234.0227 m TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com Review— Do's & Don'ts Do's • Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. • Read and follow the installation instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or firestop materials are compatible with CPVC. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Fallow proper handling procedures. • Use tools specifically designed for use with plastic pipe and fittings. • Use the proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end with a chamfering tool. • Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Make certain no solvent cement is on sprinkler head and adapter threads. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and only at a proper pressure. • Bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16" of the pipe or use a surge arrestor. • Install NIBCO® BlazeMaster CPVC Fire Sprinkler Products in wet systems only. • Use only insulation and/or glycerin and water solutions for freeze protection. • Allow for movement due to expansion and contraction. • Ensure installers have been properly trained per the NIBCO BlazeMaster® CPVC Fire Sprinkler System Installation and Design Manual and renew your training every three years at a minimum. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Don'ts • Do not use edible oils as a gasket lubricant. • Do not use petroleum or solvent -based sealants, lubricants, or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not contaminate the CPVC system with cutting oils or compressor oils. • Do not mix glycerin and water solutions in contaminated containers. • Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to CPVC grooved adapters. • Do not thread or groove CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test with air. • Do not pressure test until recommended cure times are met. • Do not exceed proper pressure for testing. • Do not use ratchet cutters below 50°F. • Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in cold weather without allowing for expansion. • Do not install NIBCO BlazeMaster® CPVC Fire Sprinkler Products in dry systems. • Do not allow puddling of cement in fittings and pipe. • Do not use dull or broken cutting tool blades when cutting pipe. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS STANDARD FITTINGS ', ', , 5001-G 1-1/4" 4233-012 80160 ti 5035 2" 4220-020 80013 Lu 5001-G 1-1/2" 4233-015 80161 ti 5035 2-1/2" 4220-025 80014 a 5001-G 2" 4233-020 80162 CD 5035 3" 4220-030 80008 a 5001-G 2-1/2" 4233-025 80163 5035-R 1"x3/4"x1"0/4" 4220-131 80015 5001-G 3" 4233-030 80164 5006 3/4" 4217-007 80050 5018 1"0/4" 4237-131 80200 5006 1" 4217-010 80051 5018 1-1/4"x1" 4237-168 80202 5006 1-1/4" 4217-012 80052 5018 1-1/4"x3/4" 4237-167 80201 5006 1-1/2" 4217-015 80053 5018 1-1/2"x1-1/4" 4237-212 80205 5006 2" 4217-020 80054 5018 1-1/2"x1" 4237-211 80204 5006 2-1/2" 4217-025 80055 5018 1-1/2"x3/4" 4237-210 80203 W 5006 3" 4217-030 80056 W 5018 2"x1-1/2" 4237-251 80209 m 5007 3/4" 4206-007 80025 ? 5018 2"x1-1/4" 4237-250 80208 "' 5007 1" 4206-010 80026 x CO) 5018 2"x1" 4237-249 80207 5007 1-1/4" 4206-012 80027 m 5018 2"x3/4" 4237-248 80206 5007 1-1/2" 4206-015 80028 5018 2-1/2"x2" 4237-292 80211 5007 2" 4206-020 80039 5018 2-1/2"x1-1/2" 4237-291 80213 5007 2-1/2" 4206-025 80030 5018 2-1/2"x1-1/4" 4237-290 80214 5007 3" 4206-030 80031 5018 2-1/2"x1" N/A 80215 5007-R 1"0/4" 4206-131 80032 5018 3"x2-1/2" 4237-339 80212 5019-H 3/4" 4253-007 N/A 5018 3"x2" 4237-338 80210 5019-H 1" 4253-010 N/A 5018 3"x1-1/2" N/A N/A 5019-H 1-1/4" 4253-012 N/A 5017 3/4" 4247-007 80100 5019-H 1-1/2" 4253-015 N/A 5017 1" 4247-010 80101 5019-H 2" 4253-020 N/A y 5017 1-1/4" 4247-012 80102 5019-H 2-1/2" 4253-025 N/A a 5017 1-1/2" 4247-015 80103 5019-H 3" 4253-030 N/A 5017 2" 4247-020 80104 H (D 5051-A 3" 4254-030 N/A 5017 2-1/2" 4247-025 80105 a J 5051-2-A 3" 4256-030 N/A 5017 3" 4247-030 80106 " 5051-H 3/4" 4251-007 N/A 5001 3/4" 4229-007 80075 5051-H 1" 4251-010 N/A 5001 1" 4229-010 80076 5051-H 1-1/4" 4251-012 N/A 5001 1-1/4" 4229-012 80077 5051-H 1-1/2" 4251-015 N/A 5001 1-1/2" 4229-015 80078 5051-H 2" 4251-020 N/A y 5001 2" 4229-020 80079 5051-H 2-1/2" 4251-025 N/A CD 2 5001 2-1/2" 4229-025 80080 5051-H 3" N/A N/A Ja 5001 3" 4229-030 80081 5011 3/4" 4201-007 8000 0 5001-R 1"0/4" 4229-131 80220 5011 1" 4201-010 8001 c� 5001-R 1-1/4"x1" 4229-168 N/A 5011 1-1/4" 4201-012 8002 5001-R 1-1/2"x3/4" 4229-210 N/A 5011 1-1/2" 4201-015 8003 5001-R 1-1/2"x1" 4229-211 N/A 5011 2" 4201-020 80004 5001-R 1-1/2"x1-1/4" 4229-212 N/A W Lu 5011 2-1/2" 4201-025 8005 5001-R 2"x1" 4229-249 N/A 5011 3" 4201-030 80006 5001-R 2"x1-1/2" 4229-251 N/A 5011-R 3/4"x3/4"x1" 4201-102 80132 5035 3/4" 4220-007 80009 5011-R 1"x1"0/4" 4201-131 80260 H W 5035 1ill4220-010 80010 5011-R 1"x3/4"x1" 4201-126 80134 N a 5035 1-1/4" 4220-012 80011 cu 5035 1-1/2" 4220-015 80012 BlazeMaster° BlazeMaster® is a registered trademark of The Lubrizol Corporation. FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 m TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH:+1/574.295.3327 • FAX:+1/574.295.3455 www.nibco.com CPVC Cross Reference Sheet STANDARD FITTINGS THREADED FITTINGS ', , 5011-R 1"0/4"0/4" 4201-125 80133 5003-S-BT 1"x1/2" N/A N/A 5011-R 1-1/4"x1-1/4"x1" 4201-168 80262 5003-BI-BSP 1" N/A N/A 5011-R 1-1/4"x1-1/4"x3/4" 4201-167 80261 5003-BI-BSP 1-1/4" N/A N/A 5011-R 1-1/4"x1"x1-1/4" 4201-159 80137 5003-BI-BSP 1-1/2" N/A N/A 5011 R 1 1/4"x1"x1" 4201 158 80136 y w 5003-BI-BSP 2" N/A N/A 5011-R 1-1/4"x1"0/4" 4201-157 80135 a 5004-BI 3/4" N/A 80157 5011-R 1-1/4"x1-1/4"x1-1/2" 4201-169 80138 a 5004-BI 1" N/A 80158 5011-R 1-1/2"x1-1/2"x1-1/4" 4201-212 80275 5004-BI 1-1/4" N/A N/A 5011-R 1-1/2"xl-1/2"x1" 4201-211 80264 5004-BI 1-1/2" N/A N/A 5011-R 1-1/2"x1-1/2"0/4" 4201-210 80263 5004-BI 2" N/A N/A 5011-R 1-1/2"x1-1/4"x1" 4201-202 80140 5018-S-BI 1"x1/2" 4238-130BR N/A y LLu u 5011-R W 1-1/2"x1-1/4"x3/4" 4201-201 80140 y ~ 5011-R 1-1/2"xl-1/2"x2" 4201-213 N/A W 5035-3-S-BI-S 1"x1"x1/2"x1/2" N/A 80462 5011-R 2"x2"x1-1/2" 4201-251 80274 0 5035-3-S-BI-L 1"xl"x1/2"x1/2" N/A 80463 5011-R 2"x2"x1-1/4" 4201-250 80267 5011-R 2"x2"x1" 4201-249 80266 W 5007-3-S-BI 3/4"x1/2" 4207-101 80199 5011-R 2"x2"x3/4" 4201-248 80265 c 5007 3 S BI 1"x1/2" 4207-130 80198 5011-R 2-1/2"x2-1/2"x2" 4201-292 80276 m 5007-3-S-BI 1"0/4" 4207-131 N/A 5011-R 2-1/2"x2-1/2"xl-1/2" 4201-291 80273 w 5007-3-S-BI 1-1/4"x1/2" 4207-166 N/A 5011-R 2-1/2"x2-1/2"xl-1/4" 4201-290 80272 5011-3-3-S-BI-S 1/2"xl/2"x1" N/A 80460 5011-R 2-1/2"x2-1/2"x1" 4201-289 80271 5011-3-3-S-BI-L 1/2"x1/2"x1" N/A 80459 5011-R 3"x3"x2-1/2" 4201-339 80269 5012-S-BI 1" 4202-010 N/A 5011-R 3"x3"x2" 4201-338 80268 5012-S-BI 3/4"0/4"x1/2" 4202-101 80250 5011-R 3"x3"xl-1/2" 4201-337 80270 5012-R-S-BI 1"x3/4"xl/2" 4202-124 N/A 5033-E 3/4" 4257-007 N/A CO) 5012-S-BI 1"xl"xl/2" 4202-130 80251 y 5033-E 1" 4257-010 N/A Lu Lu 5012-R-S-BI 1"xl/2"x1" 4203-122 N/A Z G 5033-E 1-1/4" 4257-012 N/A 5012 R S BI 1-1/4"x1"x1/2" 4202 156 80256 5033 E 1 1/2" 4257 015 N/A 5012-S-BI 1-1 /4"xl -1 /4"xl /2" 4202-166 80252 5033-E 2" 4257-020 N/A 5012 R-S BI 1-1/2"x1-1/4"x1/2" 4202 199 80257 5012-S-BI 1-1/2"xl-1/2"xl/2" 4202-209 80254 5012-S-BI 2"x2"xl/2" 4202-247 80253 THREADED FITTINGS 5012-R-S-BI 2"xl -1 /2"xl /2" 4202-237 80258 CM NIBCO SPEARS TYCO w --j 450-005 1/2" 4250-005 N/A i SIZE FIG. NO. FIG. NO. a 5003-BI 3/4" 4235-007 80142 5003-BI 1" 4235-010 80145 5003-BI 1-1/4" 4235-012 80146 5003-BI 1-1/2" 4235-015 80147 5003-BI 2" 4235-020 80148 5003-2-BI 3/4" 4278-007 N/A y 5003-2-BI o: 1" 4278-010 N/A a 5003-S-BI 3/4"x1/2" 4235-101 80175E or 80175W c 5003-S-BI 1"x1/2" 4235-130 80176E or80175W a 5003-S-BI 1"0/4" 4235-131 80179 5003-2-S-13I 3/4"x1/2" 4238-101 N/A 5003-2-S-13I 1"A /2" 4238-130 N/A 5003-S-BT 3/4"x1/2" N/A N/A Blazemaster+II BlazeMaster® is a registered trademark of The Lubrizol Corporation. +° FIRE SPRINKLER FIINGJ NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516-4740 • USA • PH:1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.336.4226 • INTERNATIONAL OFFICE PH: +1/574.295.3327 • FAX: +1/574.295.3455 www.nibco.com TO THE EXTENT PERMITTED BY LAW, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and country to country. NIBCO° BlazeMaster° Warranty NIBCO INC. LIMITED WARRANTY Applicable to NIBCO INC. CPVC Fire Protection Plastic Fittings NIBCO INC. warrants each NIBCO° BlazeMaster° Fire Protection CPVC plastic fitting to be free from defects in materials and workmanship under normal use and service for a period of ten (10) years from date of purchase. In the event any defect occurs which the owner believes is covered by this warranty, the owner should immediately contact NIBCO Technical Services, either in writing or by telephone at 1.888.446.4226 or 1.574.295.3000. The owner will be instructed to return said product, at the owner's expense, to NIBCO INC., or an authorized representative for inspection. In the event said inspection discloses to the satisfaction of NIBCO INC. that said fitting or valve is defective, a replacement shall be mailed free of charge to the owner, and NIBCO INC. shall further pay the installing contractor the sum of ten ($10.00) dollars to apply on the cost of installation of said replacement fitting. TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY SPECIFICALLY EXCLUDES INCIDENTAL AND CONSEQUENTIAL DAMAGES OF EVERY TYPE AND DESCRIPTION RESULTING FROM ANY CLAIMED DEFECT IN MATERIAL OR WORKMANSHIP, INCLUDING BUT NOT LIMITED TO, PERSONAL INJURIES AND PROPERTY DAMAGES. Some states or countries do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply to you. �__4�4 Skit BlazeMaster is a registered trademark of The Lubrizol Corporation. How to Order State quantity, figure number and size for each valve or TECHNICAL ASSISTANCE fitting you wish to order. See individual catalog pages Engineers, contractors, wholesalers or manufacturers for specific or special product designations. may obtain special or technical assistance from any factory representative of NIBCO. Write, fax or phone. HOW MANY TO ORDER NIBCO® valves and fittings are decimal packed for your convenience in handling, shipping and stock - keeping. Number in master carton varies with item. POLICY ON RETURNS TO FACTORY No NIBCO valves and fittings are to be returned with- out prior written agreement. Transportation must be prepaid. A 20% charge will be made to cover cost of rehandling and reinspection. NIBCO INC. World Headquarters 1516 Middlebury Street Elkhart, IN 46516-4740 USA PH: 1.574.295.3000 or 1.888.446.4226 FAX: 1.574.295.3307 or 1.888.336.4226 To the best of our knowledge, the information contained in this publication is accurate. However, NIBCO does not assume any liability whatsoever for the accuracy or completeness of such information. Final determinations of the suitability of any information or product for the use to be contemplated is the sole responsibility of the user. The manner of that use, and whether there is any infringement of patents, is also the sole responsibility of the user. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 • TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.219.295.3221 • FAX: +1.219.295.3455 www.nibco.com BRASTIC° Sprinkler Head Adapters FEATURES - • Sprinkler seals against CPVC when properly installed eliminating a potential leak path • Unique design provides greater resistance to radial stress along the entire length of the `-�- sealing threads • Robust starter thread to prevent sprinkler cross threading (Large lead chamfer will not remove PTFE tape or thread sealant upon sprinkler assembly) • Use sprinkler manufacturer's wrench for sprinkler install or removal , (No special wrench required to remove sprinkler head) • Dezincification and corrosion resistant • FBCTm System Compatible Program - the industry's only chemical compatibility testing program • Wrench flats for hold back • Improved torque resistance • Made in USA • U.S. Patent 6,186,558 LISTINGS AND APPROVALS - • UL 1821 Listed • Exposed system risers NFPA 13D, 13R c • Exposed basement NFPA 13D A (solid and composite wood joists) • Extended coverage (exposed) - 20' spacing on in lieu of 15' A pendent • Exposed extended coverage sidewall sprinkler B� B A B listing for exposed pipe & fittings 5007-S-BT 5003-S-BT, 5011-S-BT • Permitted for use with return air plenums with 5003-2-S-BT no set -back at ceiling openings per NFPA 90A • ULC Listed Factory Mutual Approved APPROX• , • Factory Mutual Approval exposed FIG. NO. NOM. SIZE LBS. INCHES INCHES INCHES JOINT • Factory Mutual Approval above drop -in ceilings 5003-S-BT 1"x1/2" 0.17 0.75 1.89 1.63 SxFNPT • LPCB Approved 5003-S-BT 3/4" x 1/2" 0.15 0.75 1.52 1.32 S x FNPT " 5003-S-BT 1 x 3/4" 0.16 0.90 2.08 1.62 S x FNPT • Code compliant with certifications to NSF/ANSI-61, 5003-2-S-BT 1"x1/2" 0.14 0.75 1.85 1.32 SxFNPT NSF/ANSI-372, and NSF/ANSI-14 5007-S-BT 3/4" x 1/2" 0.19 0.56 1.62 - S x FNPT 5007-S-BT 1 " x 1/2" 0.25 0.50 1.75 - S x FNPT INSTALLATION INSTRUCTIONS - 5007-S-BT 1"x3/4" 0.24 0.59 1.88 - SxFNPT For complete installation instructions see NIBCO's "Installation 5011-S-BT 3/4" x 3/4" x 1/2" 0.20 0.43 0.43 1.61 SxFNPT and Design Manual" or for Brastic installation instructions 5011-S-BT 1" 0.37 0.83 0.83 1.49 SxFNPT reference form No. IM-BLBF-0910. 5011-S-BT 1"x1"x1/2" 0.26 0.42 0.42 1.76 SxFNPT NIBCO B/azeMasterc AF1 E AO OF T n E F I Ow FIRE SPRINKLER FITTINGS BlazeMaster®is a registered trademark of The Lubrizol Corporation. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.888.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3327 • FAX: +1.574.295.3455 www.nibco.com SCOPE OF WORK: -TO DESIGN & INSTALL COMPLETE NEW FIRE PROTECTION SPRINKLER SYSTEM PER NFPA 13D 2016 EDITION. -WORK CONSISTS OF EXISTING HOME REMODEL AND ALL FIRE SPRINKLER MATERIAL IS NEW PER NFPA 13D, -ALL UNDERGROUND PIPING DONE BY OTHERS (AS NOTED ON PLANS)"CONTRACTOR UNKNOWN" LEGAL DATA CITY OF LA QUINTA RIVESIDE COUNTY PALM DESERT ADDRESS: 53821 ROSS AVENUE GENERAL NOTES: 1. SYSTEM DESIGNED IN ACCORDANCE WITH NFPA 13D 2016 EDITION. 2. ALL PIPING & FITTINGS TO BE CPVC SCH. 40 STANDARD ASTM F 438 UNO. STEEL PIPING & FITTINGS WHERE NOTED IS TO BE SCH. 40 STANDARD ASTM A-135. 3. ALL HANGERS TO BE SPACED PER MANUFACTURERS RECOMMENDATIONS AND LISTED FOR FIRE PROTECTION SERVICE. 4. ALL UNDERGROUND PIPING TO BE FLUSHED BEFORE CONNECTION TO ABOVE GROUND PIPING. 5. ALL UNDERGROUND PIPING BY OTHERS. 6. ALL WIRING OF DEVICES BY OTHERS. 7. SPARE SPRINKLERS OF EACH TYPE SHALL BE PROVIDED PER NFPA 13D. 8. NOT USED. 9. THE WATER FLOW ALARM BELL SHOULD BE POWERED BY A LIGHTING CIRCUIT FROM AN ADJACENT LIVING SPACE. A SEPARATE DEDICATED CIRCUIT IS NOT ALLOWED. 10. THE REQUIRED HYDROSTATIC TEST SHALL NOT BE LESS THEN CITY PRESSURE PER NFPA 13D. THERE IS NO FDC PER THIS CONTRACT DESIGN. 11. THE CONTROL SERVICE VALVES SHALL BE SEALED OPEN OR THE HANDLES REMOVED W/ THE VALVES IN THE FULLY OPEN POSITION. 12. ALL PROTECTIVE CAPS TO BE REMOVED BEFORE FINAL INSPECTION. 13. ALL PENETRATIONS THROUGH FIRE RATED WALLS SUCH AS WALLS AND CEILINGS BETWEEN ATTACHED GARAGE AND RESIDENCE WILL BE SEALED IN AN APPROVED MANNER. 14. DRILLING OR NOTCHING OF STRUCTURAL MEMBERS SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE CURRENT CBC 2019 EDITION. 15. NOT USED. 16. STORAGE IN ATTIC IS NOT ALLOWED. 17. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL THE FOLLOWING CONDITIONS: (1)AREA OF THE SPACE DOES NOT EXCEED 24 SQFT. (2)THE WALL & CLG. ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. AS DEFINED IN NFPA 220. 18. SPRINKLER HEADS OMITTED IN BATHROOMS DUE TO NON-COMBUSTIBLE FIXTURES AND LESS THAN 55 SQUARE FT. RULE. 19. THE FIRE SPRINKLER INSTALLER SHALL PROVIDE TO THE OWNER/OCCUPANT INSTRUCTIONS ON INSPECTING, TESTING AND MAINTAINING THE SYSTEM. 20. A SIGN SHALL BE AFFIXED ADJACENT TO THE MAIN SHUT-OFF VALVE THAT STATES IN MINIMUM 4" LETTERS "WARNING, THE WATER SYSTEM FOR THIS HOME SUPPLIES A FIRE SPRINKLER SYSTEM THAT DEPENDS ON CERTAIN FLOWS AND PRESSURES BEING AVAILABLE TO FIGHT FIRE. DEVICE THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUT OFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. DO NOT REMOVE THIS SIGN. 21. THE INSTALLING CONTRACTOR SHALL PROVIDE TO THE OWER/OCCUPANT INSTRUCTIONS ON INSPECTING, TESTING, & MAINTAINING THE SYSTEM. NFPA 13D 2016 EDITION MULTIPURPOSE PIPING SYSTEM. A PIPING SYSTEM SERVING BOTH SPRINKLER AND DOMESTIC NEEDS SHALL BE CONSIDERED TO BE ACCEPTABLE BY THIS STANDARD WHERE THE FOLLOWING CONDITIONS ARE MET: (1) IN COMMON WATER SUPPLY CONNECTIONS SERVING MORE THAN ONE DWELLING UNIT, 5 GPM (19 L/MIN) SHALL BE ADDED TO THE SPRINKLER SYSTEM DEMAND TO DETERMINE THE SIZE OF COMMON PIPING AND THE SIZE OF THE TOTAL WATER SUPPLY REQUIREMENTS WHERE NO PROVISION IS MADE TO PREVENT FLOW INTO THE DOMESTIC WATER SYSTEM UPON OPERATION OF A SPRINKLER, (2) ALL PIPING IN THE SYSTEM SUPPLYING SPRINKLERS IS LISTED AND CONFORMS TO THE PIPING SPECIFICATIONS OF THIS STANDARD. (3) PIPING CONNECTED TO THE SYSTEM THAT SUPPLIES ONLY PLUMBING FIXTURES COMPLIES WITH LOCAL PLUMBING AND HEALTH AUTHORITY REQUIREMENTS BUT IS NOT REQUIRED TO BE LISTED. (4) PERMITTED BY THE LOCAL PLUMBING OR HEALTH AUTHORITY, (5) WARNING SIGN. A SIGN SHALL BE AFFIXED ADJACENT TO THE MAIN SHUTOFF VALVE THAT STATES IN MINIMUM 1/4 IN. (6.4 MM) LETTERS, WARNING, THE WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND PRESSURES TO FIGHT A FIRE. DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM, SUCH AS WATER SOFTENERS, FILTRATION SYSTEMS, AND AUTOMATIC SHUTOFF VALVES, SHALL NOT BE ADDED TO THIS SYSTEM WITHOUT A REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST. DO NOT REMOVE THIS SIGN. (6) WHERE WATER TREATMENT AND FILTRATION ARE INSTALLED. ONE OF THE FOLLOWING CONDITIONS SHALL BE MET: (A) THE FLOW RESTRICTION AND PRESSURE LOSS THROUGH THE WATER TREATMENT EQUIPMENT SHALL BE TAKEN INTO ACCOUNT IN THE HYDRAULIC CALCULATIONS. (B) AN AUTOMATIC BYPASS SHALL BE INSTALLED AROUND THE WATER TREATMENT EQUIPMENT THAT DIRECTS ALL WATER DIRECTLY TO THE SYSTEM. NOTE: THIS SPRINKLER SYSTEM IS DESIGNED SO THAT THE SYSTEM SPLIT IS @ THE BOTTOM OF THE SYSTEM RISER. NO SPRINKLER PIPING IS TO PASS THROUGH THE FILTRATION SYSTEM AT ALL. ELE ® TOR= 10'-6" r--------------------- 7 1i" FIRE RISER CPVC INSIDE WALL WITH[ INTERIOR ACCESS PANEL I L--------------------- J 1j" NIBCO RUBBER SEATED CH VALVE DOMESTIC CONTROL VALVE BOTH DOMESTIC & SPRINKLER - OPTIONAL CONTROL VALVE "GLOBE VALVE NOT ALLOWED" 1" CPVC PIPING TO RESIDENCE 300 PSI WATER PRESSURE GAUGE RELEIF VALVE SET TO �ADJUSTABLE PRESSURE 150 PSI " MAIN TEST & DRAIN VALVE, � ORIFCE J" MAIN DRAIN PIPE TO EXTERIOR LOCATION REFF. ELE ® BOR = 2' "TRANSITION COPPER TO CPVC INSIDE WALL CAVITY" 1j" COPPER TYPE Y' 2" PVC UNDERGROUND PIPE UP EXTERIOR OF WALL FROM METE UG1 REFF. ELE ® UG1 FLR. = -3' R15ER DETAIL pROTECT� ?1< P F IRE p cpL U CLASSIFICATION 0 O C-16 0 LICENSE NO. 2 1016781 F OF CA`I 0 oo Residential Connection Charge Estimate August 16, 2022 ° _ ��� ^� ° ° 8 ° o ° d r r �g °° ° $ Customer Name: ° Richard Doan v 3 ° a° °o o ° p � � Phone No. 0. B (858) 204-618$ ° ° � o 1Polh° Parcel No. 779-490-014 ° °° ° °o ° L' Geo. 06-07-10-3 gam° ° ° o°Address: 0 0 o 53821 Ross Avenue, La Quinta LID: 668036 Block No. ° °op oo c ° �' A Lot No. 39 Size of Lot: 47,916 S , ft. Tract No. 33076-1 0 � a o%p Type of Service: R_1 . Duplex: ❑ Triplex: Apts: ° WDOF: $ acres: WSBFC: $° ❑❑ �8° °eoo�O °°` �C 0 o $ ° / Collaciit: $1,785 on: $2,748/edu 0° Treamllastedu p Meter: $ el °e 937 *a .00 a }'`I o °°a, - 0, t,°Q , Mete. Size: 1+1/2 inch : ° 0 o%� ° ° 4 04 Meter surcharge: $ 8,733.00 �° ° Servkeslze: 2 inch � ° ° 0 ° Service: $ °� o° °p� Meter &Service' $ e00 ° Not LafldlCa ° °� °°� °°° V o °o ° It I a °4 o ° �� ° 0 Po ° o 0°^ R$Ap ° q le, 9° ° U °° 8 u t,o P ° 0 0 �Min. 4112° 0 °°% °8 0 0 ° ° 0� °6 o �q4 ° 0N� °o p oq o: °° ° ., o 0 < .,It ° 9 % 4 'Poo. e o 04 ° °o oo�o° oo �o m.� °og y° �o�o $ °e� ° °a� o$°� °p;�o 0 0o go° ° °�� �S°° a°°�13. � �oo�o'o' ° p� o� ,� ,40 °4° , a °m° % ,�o b b o ° 9°°° °°a o% ea ,� °a 0m a 4 °4 °t=, °-b °_b e 0 0 - p� Backflow: vo° es: pe ansapprowd. 8 � � o $_o° 77'7 � Other: $ o � b � "V ° Madison Club. Spacial Asretm ent - No WSBFC, only TFC o1 SCC. n Sewer Lateral: $ _ o o TFC M pd CR 111101. WOOF satisTied per MR 10i226.Cdlect all 7 ° ° Total: $ 9,670.00 other fees. Per dwg 34195 a 2" service exists, per dwg 31210 a lateral exits. P2 22.13720 Technician: Lisa Sanchez FeesA=Z Z Information Supplied By Customer CVWD System Data Domestic Water Demand' � Serviu t.OnnaCtlOn •• o r °8O °O 6° y °uo ° A'p0 ° o ° ° ❑0 ° g°° o g ° Max. Flow= 3 i gpm a °b o°, °o# Max Fbw•= 37 gpm Min. Pressure= 46 51 ° 'Co ° � Inlet Pr 71.$6 °o CITY WATER INFO. STATIC: 71.86 psi RESIDUAL: 20 psi FLOW: 500 gpm METER SIZE= 12" LATERAL SIZE= 2" LATERAL TYPE= COPPER TYPE "K" NOTE: 10% REDUCTION HAS BEEN USED IN DESIGN. HYDRAULIC - SYSTEM HYDRAULIC - SYSTEM HYDRAULIC - SYSTEM THIS BUILDING IS PROTECTED THIS BUILDING IS PROTECTED THIS BUILDING IS PROTECTED BY A HYDRAULICALLY DESIGNED BY A HYDRAULICALLY DESIGNED BY A HYDRAULICALLY DESIGNED AUTOMATIC SPRINKLER SYSTEM AUTOMATIC SPRINKLER SYSTEM AUTOMATIC SPRINKLER SYSTEM PER NFPA 13D, 2016 EDITION PER NFPA 13D, 2016 EDITION PER NFPA 13D, 2016 EDITION LOCATION DESIGN AREA 1 LOCATION DESIGN AREA 2 LOCATION DESIGN AREA 3 NO. OF SPRINKLERS 2 NO. OF SPRINKLERS 1 NO. OF SPRINKLERS 2 BASIS OF DESIGN BASIS OF DESIGN BASIS OF DESIGN DENSITY: .05 GPM SQ.FT. DENSITY: .05 GPM/ DENSITY: .05 GPM SQ.FT. MIN. FLOW & PRESSURE PER SPRINKLER MIN. FLOW & PRESSURE PER SPRINKLER MIN. FLOW & PRESSURE PER SPRINKLER 13 GPM AT 7.039 PSI 21 GPM AT 18.4 PSI 13 GPM AT 7.039 PSI SYSTEM DEMAND AT THE BASE OF RISER SYSTEM DEMAND AT THE BASE OF RISER SYSTEM DEMAND AT THE BASE OF RISER GPM DISCHARGE 26.45 GP GPM DISCHARGE 21.02 GP GPM DISCHARGE 26 GPM RESIDUAL PRESSURE 46.989 PSI RESIDUAL PRESSURE 49.533 PSI RESIDUAL PRESSURE 52.130 PSI DOMESTIC DEMANDED 5.0 GPM DOMESTIC DEMANDED 5.0 GPM DOMESTIC DEMANDED 5.0 GPM SYSTEM DEMAND AT SOURCE SYSTEM DEMAND AT SOURCE SYSTEM DEMAND AT SOURCE GPM DISCHARGE 31.454 GP GPM DISCHARGE 26.019 GP GPM DISCHARGE 31.003 GP RESIDUAL PRESSURE 54.266 PSI RESIDUAL PRESSURE 55.889 PSI RESIDUAL PRESSURE 59.325 PSI *SAFTEY FACTOR 10.128 PSI *SAFTEY FACTOR 8.588 PSI *SAFTEY FACTOR 5.077 PSI CALIFORNIA FIRE PROTECTION AND BACKFLOW CONTACT INFO OFFICE:949.770.5371/www.cafireprotection.com General Notes All Pipe Locations are to be Field Measured Prior to Fabrication and Installation by Sprinkler Contractor. All Dimensions Shown are Center to Center. High Temperature Heads are to be Field Located Where Required. All Pipes and Hangers are to be Installed per NFPA #13D. Hangers are to be U.L. Listed. ,d •� ....�•. .JJ_ JJJ • .:.i :•'r.•:•:•:•: :•:% JJ �. ',• J JJJJJJJJ'JJJJJJ .. • J J ' . '1 JJJJJ.IJJJ.J ' . J • JJ�J�JilJ J.IJ •� • 'JJJJJJJ' JJ' JJJJJ �••. JJ JJJJJJJJ Il .. a J • JJJJJ .I I.I I.I >1 jJ / Eli, J JJJ I.I .I I.I L l YI II J 1J J•J JjJJa Symbols ymbol Description Q Hydraulic Reference Points Ceiling Height Denotes Hanger Location o Rise up or down - 10, - pai-041tw"'E/i, - -X:-- 0 = - 0 - �__ _ _ r _ -- _ _ JJ J•JJ. ' JJJ .•.•• - - __ _ _ _ _ -_ --'3•y � T_ . J J .7 � • J� JJ _ � .,✓ - - •'R •. - - __ : • JJJJJJJ 7J•JJ J - - � - - - - J J • J 7� JJ - 7,r�J JJ • ••JJJ - � ?J= __- _- -__ = - __ =4` _ •.k+�!•':.�: �,,]]��JJ�-1J J J ' ���t • ...'.'.:'.:'.:•.• ..:'.'.:': •'••'.:•.' ..:::'."'.:'.: J '. ' JJ - � r - ` � 1. _- - �JJJJJJJJ r .. } .:.'.:':.::'.'.'.:'.:'. JJ - - - _ - ♦' . ..' JJ.1 J JJJ • �• JJJ • • - - _ _ .•: JJJJJ J J : .. Jr y• - JJJJ J� J J - `_ '. J tu.....:.'.:•...:'.'....... JJ JJ •Jell .JJJ - •J .'0:•..::...::':: •.:'.'.'.:"'..::': .. J. •••�J •• d ::'JJJJJ • .. .... •..... ...... •.... JJ•�•..:'.:'. :'...............�i JJJJJJJ JJJJ] ' JJJJJ � '•••.., JJJ � J•JJ JJ J - r1��JJJJJ �.-, •• • • ...... " .JJJ .. 1�••.'.:'.'.'.' • yJ• J 1 Y.ILJJJJ J J •••J: •'�:'•::'.: J J -- JJJJJJJJ � '•': JJ .' JJJ.f,� J• - � :fJ 'J•JJIJJJ• ♦ JJJJ _1J "''•::•.'." •: • .: '• • J JJJJJ Jd .'•' • - I JJJ _� `_ .:}J�'.•.:'.'.:::'.:':'.:'.•.'.:.... )'JJJJ J •..'J d°0 - ` '.::'.:'.:'.'.::....:.. •JJJ '.'.'.:•.:'.:•'.. iD © ® JJJJJ JJJJ - - ` JJ• •,J Jlz� O� - - JJJJ) JJJJ "•`. `.�••:. •JJJJ,••. •'. :'.'.'.:'.::'.'.:'.::'.'. J J `.�O L- dre J ® JJJJ) JJJJ r� LO � ' J•JJJJ�J .: JJJJ R. f�IL )JJJJ_ )JJJJ_ JJJJJJJJ_ JJJJJJJJ_ JJJ_ JJJJJJJJ_ JJJJJJJJ_ JJJJJJJJ_ L------ ---- JJJJJJJ_ I i 0 � � JJ JJJ. � •JJJ , '}J. JJ'JJJJJd JJJ •••.::•:•••• •. J JJJJJJJJ J• .......:'.... J CD a-- JJJJ JJ SJy�J� J J 'JJ JJJJ JJJJJJJJSJ�r� �J '• • J • lJ r J• • JJJ JJJJJJJJJJJJJJJ JJ JJJJ 3 JJJJ JJJJJJJJJJJJJJJJJJ JJJJJJ ,•JJJ ; JJJ JJJJJ) JJJJJJJJJJJJJJJyyJJJJ�JJ3J J r ,��]]ffJJJ JJJ )JJJJJ JJJJJJJJJJJJJJJJJJJJ ,IJJ� •••::•.''••. •••• JJJJ JJJJJ) JJJJJJJJJJJJJJJJJJJJ JjJJ,J7J�J •••.., ���Fl� JJJJ JJJJJJJ JJJJJJJJ) J • • :':: '•, • )JJJ )JJJJJ JJJ JJ)JJJJJJLJJJJJJJJJJJJJJJJJJJJJJJ J•JJ , )JJJ JJJJJJ JJJ JJ J• JJJJJJJ JJJJJJJJJJJJJJJJJJJJ :fJJ .:;':• JJJJJJJJ JJ )JJJJJJJJJJJJJJJ J JJJ ,•�•:.: : JJJJJJJ JJ )JJJJJJJJJJJJJJJ J J•J JJJJJJJ J JJJJJJJJJJJJJJJ J J J•:.;••;••�,� )JJJJJ JJ JJJJJJJJJJJJ JJ •:JJJ 4 JJJJJJJ J JJ JJJJJJJJ) J J JJJ JJJJJJJ J )JJJ JJJJJ) J JJ J. JJJJJJJJJJJJ )JJJ JJJ JJ JJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJVJJJJJ JJ d JJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ JJJJJ J„ JJ ,J•JJ , {{{{JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ )JJJJJ JJJ J• . JLJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ.JJJJ JJJ 4 rN SCALE 1/32" = 1'-0" SITE MAP/PIPING PLAN ()ALL NOTE: ALL UNDERGROUND PIPING TO BE INSTALLED BY OTHERS. UNDERGROUND PIPING SHOWN FOR HYDRAULIC REFERENCE ONLY. BUILDING SUMMARY OCCUPANCY: R3/U CONSTRUCTION TYPE: V-B NFPA 13D 2016 EDITION DOAN RESIDENCE 1ST FLOOR AREA = 11,162 SF 1ST FLOOR -GUEST HOUSE AREA = 2,203 SF 2ND FLOOR AREA = 4033 SF LIVING AREA = 17,398 SF GARAGE & STOR., EQUIP RM = 2,043 SF COVERED ENTRY & VERABDA & PATIO = 1,626 SF Drawing Cover sheet/Piping Plan Title JJ JJJ. � •JJJ , '}J. JJ'JJJJJd JJJ •••.::•:•••• •. J JJJJJJJJ J• .......:'.... J CD a-- JJJJ JJ SJy�J� J J 'JJ JJJJ JJJJJJJJSJ�r� �J '• • J • lJ r J• • JJJ JJJJJJJJJJJJJJJ JJ JJJJ 3 JJJJ JJJJJJJJJJJJJJJJJJ JJJJJJ ,•JJJ ; JJJ JJJJJ) JJJJJJJJJJJJJJJyyJJJJ�JJ3J J r ,��]]ffJJJ JJJ )JJJJJ JJJJJJJJJJJJJJJJJJJJ ,IJJ� •••::•.''••. •••• JJJJ JJJJJ) JJJJJJJJJJJJJJJJJJJJ JjJJ,J7J�J •••.., ���Fl� JJJJ JJJJJJJ JJJJJJJJ) J • • :':: '•, • )JJJ )JJJJJ JJJ JJ)JJJJJJLJJJJJJJJJJJJJJJJJJJJJJJ J•JJ , )JJJ JJJJJJ JJJ JJ J• JJJJJJJ JJJJJJJJJJJJJJJJJJJJ :fJJ .:;':• JJJJJJJJ JJ )JJJJJJJJJJJJJJJ J JJJ ,•�•:.: : JJJJJJJ JJ )JJJJJJJJJJJJJJJ J J•J JJJJJJJ J JJJJJJJJJJJJJJJ J J J•:.;••;••�,� )JJJJJ JJ JJJJJJJJJJJJ JJ •:JJJ 4 JJJJJJJ J JJ JJJJJJJJ) J J JJJ JJJJJJJ J )JJJ JJJJJ) J JJ J. JJJJJJJJJJJJ )JJJ JJJ JJ JJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJVJJJJJ JJ d JJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ JJJJJ J„ JJ ,J•JJ , {{{{JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ )JJJJJ JJJ J• . JLJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ.JJJJ JJJ 4 rN SCALE 1/32" = 1'-0" SITE MAP/PIPING PLAN ()ALL NOTE: ALL UNDERGROUND PIPING TO BE INSTALLED BY OTHERS. UNDERGROUND PIPING SHOWN FOR HYDRAULIC REFERENCE ONLY. BUILDING SUMMARY OCCUPANCY: R3/U CONSTRUCTION TYPE: V-B NFPA 13D 2016 EDITION DOAN RESIDENCE 1ST FLOOR AREA = 11,162 SF 1ST FLOOR -GUEST HOUSE AREA = 2,203 SF 2ND FLOOR AREA = 4033 SF LIVING AREA = 17,398 SF GARAGE & STOR., EQUIP RM = 2,043 SF COVERED ENTRY & VERABDA & PATIO = 1,626 SF Drawing Cover sheet/Piping Plan Title JJJJ JJ SJy�J� J J 'JJ JJJJ JJJJJJJJSJ�r� �J '• • J • lJ r J• • JJJ JJJJJJJJJJJJJJJ JJ JJJJ 3 JJJJ JJJJJJJJJJJJJJJJJJ JJJJJJ ,•JJJ ; JJJ JJJJJ) JJJJJJJJJJJJJJJyyJJJJ�JJ3J J r ,��]]ffJJJ JJJ )JJJJJ JJJJJJJJJJJJJJJJJJJJ ,IJJ� •••::•.''••. •••• JJJJ JJJJJ) JJJJJJJJJJJJJJJJJJJJ JjJJ,J7J�J •••.., ���Fl� JJJJ JJJJJJJ JJJJJJJJ) J • • :':: '•, • )JJJ )JJJJJ JJJ JJ)JJJJJJLJJJJJJJJJJJJJJJJJJJJJJJ J•JJ , )JJJ JJJJJJ JJJ JJ J• JJJJJJJ JJJJJJJJJJJJJJJJJJJJ :fJJ .:;':• JJJJJJJJ JJ )JJJJJJJJJJJJJJJ J JJJ ,•�•:.: : JJJJJJJ JJ )JJJJJJJJJJJJJJJ J J•J JJJJJJJ J JJJJJJJJJJJJJJJ J J J•:.;••;••�,� )JJJJJ JJ JJJJJJJJJJJJ JJ •:JJJ 4 JJJJJJJ J JJ JJJJJJJJ) J J JJJ JJJJJJJ J )JJJ JJJJJ) J JJ J. JJJJJJJJJJJJ )JJJ JJJ JJ JJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJVJJJJJ JJ d JJJ JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ JJJJJ J„ JJ ,J•JJ , {{{{JJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ )JJJJJ JJJ J• . JLJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJJ.JJJJ JJJ 4 rN SCALE 1/32" = 1'-0" SITE MAP/PIPING PLAN ()ALL NOTE: ALL UNDERGROUND PIPING TO BE INSTALLED BY OTHERS. UNDERGROUND PIPING SHOWN FOR HYDRAULIC REFERENCE ONLY. BUILDING SUMMARY OCCUPANCY: R3/U CONSTRUCTION TYPE: V-B NFPA 13D 2016 EDITION DOAN RESIDENCE 1ST FLOOR AREA = 11,162 SF 1ST FLOOR -GUEST HOUSE AREA = 2,203 SF 2ND FLOOR AREA = 4033 SF LIVING AREA = 17,398 SF GARAGE & STOR., EQUIP RM = 2,043 SF COVERED ENTRY & VERABDA & PATIO = 1,626 SF Drawing Cover sheet/Piping Plan Title SCALE 1/32" = 1'-0" SITE MAP/PIPING PLAN ()ALL NOTE: ALL UNDERGROUND PIPING TO BE INSTALLED BY OTHERS. UNDERGROUND PIPING SHOWN FOR HYDRAULIC REFERENCE ONLY. BUILDING SUMMARY OCCUPANCY: R3/U CONSTRUCTION TYPE: V-B NFPA 13D 2016 EDITION DOAN RESIDENCE 1ST FLOOR AREA = 11,162 SF 1ST FLOOR -GUEST HOUSE AREA = 2,203 SF 2ND FLOOR AREA = 4033 SF LIVING AREA = 17,398 SF GARAGE & STOR., EQUIP RM = 2,043 SF COVERED ENTRY & VERABDA & PATIO = 1,626 SF Drawing Cover sheet/Piping Plan Title Contract No. 22-53821 Revisions: Drawn By CFP&B Scale "As Noted" Date 9.29.22 Approval By 11" FIRE RISER INSIDE WALL W/ INTERIOR PER NFPA 13D 2016 EDITION TABLE 10.4.4fC1 EQUIVALENT LENGTH USED FOR DEVICES INSTALLED CITY MAIN ARE AS FOLLOWS: / 2 2" ANGLE VALVE = 28 FEET 2" COCK VALVE = B FEET TOTAL LENGTH ADDED TO SERVICE / LINE = 36 FEET IN CALCS\ 2 i p�U 1j" WATER METER LOCATION REFF, ELE. METER = -3' �_- a W. 52 ' CGLLJMBUS WAY Cr z� IJJ 0 to APG���� AVE. 53 o � � PEARY `o PL. SITE A VT. 54 MCNTY VAP APPROVED BY: Job: Doan Residence Date' 53821 Ross Avenue La Quinta Ca 92253 Contractor: California Fire Protection & Backflow 647 Camino De Los Mares San Clemente, Ca 92673 lo VAP APPROVED BY: Job: Doan Residence Date' 53821 Ross Avenue La Quinta Ca 92253 Contractor: California Fire Protection & Backflow 647 Camino De Los Mares San Clemente, Ca 92673 lo �, pFV IRE / Q��\ �Q P U CLASSIFICATION C-16 0 v LICENSE NO. 1016781 I,- F CA%1F 12ND FLOOR & SECTION ON GHEE? 3-------------------------------------------------------- 29 Q.FT " 20X20 HER B 28 SQ.FT SPACING 10'-1" CLG. i. 1_24" _2" 9 181� M® � 0 15 -5 9-815 B � A 10'-1" CLG i 120X20 I -, ® SPACING o o------I- ---- N z 10'-1" CLG.I'V HALL I STOR r----------------------- - 11M 1 ______ ® ® ® 10'-1" CLG. ® ® i 10'-1" CLG. I r I I-"-_15'-10 " 3'-s" -5 LOW5 3 2 w T 1 1 20X20 Alk 20X20 2L1 5-5 SPACING G 1 1 SPACING - 15-101i 5- d '-3d"5 -3" -s" co HALL --- g I 10'-1" CLG. / CL J 3'-6 13'-4" got" R3'-0" 10'-1" CLG. N d55 —d55 — SS 0 L OFFICE I U 1 --- 20X20 CLOSET 1 1 12'-1" CLG. H4 ti wQ C11\ / '� SPACING N 1L1-"JCL 10�-1" CL . 0-6 0-8 1 ESIGN A_ N A I BED 1 ® ® ® I --� i I I 1 12'-1 CLG. I � L' l03 �' / L' I 1 1 s dmS — S99 — d*S 1d�S des J 1 1 I 1 2 101 i, 5 15-101� 5-3 - -3 3-6)�Z 4 I ® ® o" o Df� 2i ^c. � 0 2-11 / HEAT ZONE 06 `� 10'-1 C I HALL i �= FIRE PLACE 0'-1" CLG. EE L 1ft 016 0-8 � CL S tx 4-8 � �I ® ® ° I I I Q - T 10 BACKLIT ONYX ______ 4 I s----r------ -Ll LG. CHANGE FIRE PLACE 1 I 1 I a M N 0 HEAT ZONE I j I L5'-94" 12-5 F IIII 12'-5" LIVING RM I I 12'-1" CLG. �0 I I I I I 0 I I I I I I I C) 1 I I j 0 I * I 12-5 I I 0 I i 0 I I I I io I n CD I 1 z LIVING RM I I � 12'-1" CLG. I 0 i 0 I I I 1 12-5 I I I I I I I I I I I I I I I I I I I 10'-0" WINE 0 20X20 1-10 ❑ %__ ® --- 10'-1" CLGSPACING Li y 1 -9S4 4-8 —12'-5 � �2 1 1 .❑. -M. I I I - I I ;110'-1" G. HALL ® 0 10'-1" CLG. c>I ® I I II f 1 1 �� 0 I I ,, I 11-10 T I 3- � I _ M - FM I I I 1 BATH i 9-1" CLG. i I II I I I I II �- BED 2 12'-1" CLG. o1 1 1 6-3 I^ I I I I L i 11'-10" SPRINKLER HEAD LEGEND SYMBOL MANUFACTURER MODEL SIN I TYPE TEMP.F ORIFCEK-FACTOR N.P.T FINISH ESC QTY. SENJU RC-RES I SS8464 ICONCEALED PENDEN 162° 7 16" 4.9 1 2" WHITE CON. 130 • SENJU RC-RES I SS8464 ICONCEALED PENDEN 205° 17 16" 4.9 1 2" WHITE CON. 18 TOTAL SPRINKLERS THIS PROJECT 148 SENJU SS8464 162 SPRINKLERS ARE DESIGNED FOR 16'x16' (256 S.F.) MAXIMUM & 8' MINIMUM SPACING. 13gpm @ 7psi. COMPARTMENTS WITH ONLY 1 SPRINKLER SHALL BE ALLOWED TO BE SPACED 20' x 20' 10' MAXIMUM OFF ANY WALL PER DESIGN AREA #2. 7'-221"—�-7'-24 I 7'-5" 3'-8" M 1 6 SQ. r - 0-5 ® IS BED 1 BATH CL 0, LG. I 10'-1" CLG. -1 CL . - CT_ _I I •� rn -3 -11 BED 2 I I r I dAS — dAS J 10'-1" CLG. r i o a �/ I I I HALL 1 - 15 0'- ®CLG. 1 '-1" CLG. LL I 1 Io' 1 o 0•� 50 SQ.FT 3 - I e I 0-5 ® 1 0® 10'-1d S ____ 0-7 1 7 I (0 3-0 \ M I ® LI a 3'-6 3'-6" I � 2 S Ff V "' 1 •cn 1 10 7-7 7-9 5 11 9-4Fi I N 0 0 0 BED 3 I pKITCHE®- • ^ 10'-1" CLG.- N o o LIVING RM T 0 10'-1" CLG. �I L0 / o j o 010- ---- 1 0I� 0-7 1 -7 Ll I = 0 -1 CLG. 1 \ O N I 0-61i II 0 2-11 I t7'-11"—I -�' 15'- 0" 7'- L 10 0 I LL I L---------------------------------------------- 2 BTH >60" COUNTRYARD COUNTRYARD I EXTERIOR EXTERIOR I EN Y II 11'-1 CLG. PIPING CONCEALED ABOVE STUCCO CLG I L�� 7 -101 4 - - - - - - - - - - - - - - - - - - - - EQ 10'-l" CLG. L - 0 0 I � ®10' 6 111 I 1 1 1 1 1 1 1 1 3 11 2-4h I 111-11 1 113-54-5 f 0 1 0 �M ® ® M ® ® M ® T 1 BAR REC N _ � o I I n I i ,I I 2'-1" CLG. o 0 12'-1" CLG. o GARAGE I 'T'1 ao ao 00 10'-1" CLG. I I I I I ® ® 1 W Z ® ® 0 0 a 1 ®0-8 Iv co UI c ° N C> VI ® _I I -8" -34" -7" _--- CL 1 I 1 0 1---------------------- N0'-1" 7-11¢ ' 3l1 -2" .8 ® BED 3/GYM o 0 ® 1 0 0 10,-1" C �, L. - s 10'-1" CLG. � I MUD LG. 13-1 I FAU FAU / I -------------------------- MEDIA i 20X200 1 1 i 10'-1" CLG. i j SPACING r rI EQ 110'-1" CLG." 116 �r 0- CLG 10- G N �ULN a 28 FT 0 0 - 28 FT ® 10'-1" CLG. 0 dAS dBS J `Y '"I -6" 5'-3" 10'-6j" 5'-3" AAW I ------------------------------------------------------------------------------ OPEN TO ABOVE 0 I I i� I L--- KITCHEN---�Q+--------- 0 4 I �I 04 - I u 1 ,o I; x 1 ­4 JIE�/--� 0-9 , l5d 14—L AEAT 0_UY1 ' Lj 0—OX2 ' 0-1CLG. CHANGE ZONE TP4, qj� "' CLG. CHAME ------ 10 CLI co I, 1 SPACING 1 6-5 2-7 4-5 00 0 0 00 HALL 10, PAN/KIT 2 - - ° " °i 10'-1" CLG. ® 0 10'-]" CLG. _3 1'-11J" cv o '�� L111 ---------- j - 4-5 a dAS — CBS — dAS — d*S — d*S (G I 20X2��y PDR 1 o SPACINGS ® 10'-1 1 CLG. I 0 1 N 2-10 11-714 _ I I ` � $ I " I I N of I I� I AmFIRE PROTECTION AND BACKFLOW CONTACT INFO OFFICE :949.770.5371/www.cafireprotection,,com OPEN TO ABOVE COUNTRYARD EXTERIOR c � BAT O, 0 ° 10'-1 CLG, I I I ---------------------------------------------------------- G 1ST FLOOR PIPING PLAN ? 4 y SCALE 1/8"=1'-O" General Notes Symbols Symbol Description All Pipe Locations are to be Field Measured Prior to Fabrication 0 Hydraulic Reference Points and Installation by Sprinkler Contractor. Ceiling Height All Dimensions Shown are Center to Center. Denotes Hanger Location High Temperature Heads are to be Field Located Where Required. o Rise up or down All Pipes and Hangers are to be Installed per NFPA #13D. Hangers are to be U.L. Listed. 0 1j" FIRE RISER INSIDE WALL WITH INTERIOR ACCESS PANEL "^ACCESS ^PANEL " ® 0 1 0 1 1 TOR 13 5 � 9 0 8-1 I � I 0 I o 0 0 [--7'-10" GARAGE STORAGE 10'-1" CLG. 10'-1" CLG. EQ 10'-1" APPROVED BY: BUILDING SUMMARY Drawing 1st Floor -Fire Sprinkler Piping Plan Title Job: Doan Residence 53821 ROSS Avenue La uinta Ca 92253 OCCUPANCY: R3/U CONSTRUCTION TYPE: V-B Contract No. 22-53821 Revisions: Date: NFPA 13D 2016 EDITION DOAN RESIDENCE Drawn By CFP&B 1ST FLOOR AREA = 11,162 SF 1ST FLOOR -GUEST HOUSE AREA = 2,203 SF Scale "As Noted" Contractor: California Fire Protection & Backflow 647 Camino De Los Mares San Clemente, Ca 92673 2ND FLOOR AREA = 4033 SF A = 40 LIVING AREA s SF Date 9.29.22 GARAGE & STOR., EQUIP RM = 2,043 SF COVERED ENTRY & VERABDA & PATIO = 1,626 SF Approval By AHJ: CITY OF LA QUINTA �, L =_" cf) W �\\p pFtOTECT)�\ �Q P V IRE 2� oI oT U CLASSIFICATION C-16 0 v LICENSE NO. 1016781 FOF CA1IF 02PJD FLOOR PIPING PLAN SCALE 1/8"=1'—O" CALIFORNIA FIRE PROTECTION AND BACKFLOW CONTACT INFO OFFICE :949.770.5371/www.cafireprotection,,com SECTION A I I SCALE 1 /8"i 0 i INSTALLATIONS NOTES: — WHERE SOLVENT CEMENT IS USED AS THE PIPE AND FITTINGS BONDING AGENT, SPRINKLERS SHALL NOT BE INSTALLED IN THE FITTINGS PRIOR TO THE FITTINGS BEING CEMENTED IN PLACE. — SPRINKLER HEADS SHALL BE LOCATED A MINIMUM OF 3 FEET FROM THE CENTER OF A CEILING FAN, SURFACE MOUNTED LUMINAIRE OR SIMILAR OBJECTS. — COVER PLATES ARE NOT TO BE INSTALLED 0 FINAL INSPECTION BUT ARE TO BE ON THE JOB SITE. NOTE: ALL CPVC PIPING IN ATTIC SHALL BE PROVIDED WITH INSULATION ON THE ATTIC SIDE OF THE PIPING TO AVOID EXPOSURE OF THE PIPING TO TEMPERATURES IN EXCESS OF THE PIPES RATED TEMPERATURE. PIPING SUPPORT NOTES: SECTION 7.4.1: 2014 RC, SECTION R313.3.3 PIPING SHALL BE SUPPORTED IN ACCORDANCE WITH THE PIPE MANUFACTURER'S AND SPRINKLER MANUFACTURERE'S INSTALLTION INSTRUCTION. 2016 NFPA 13D. Table 1 Maximum Support Spacing Distance End Line Sprinkler Head Drop Elbow Pie Size Svstem Pressure inches <1 0 si >100 PSI 3 4 9 6 1 12 9 1-1 4 16 12 1-1 2 — 3 24 12 Table 2 Maximum Support Spacing Distance Inline Sprinkler Head Drop Tee Pie Size Svstem Pressure inches <1 0 IDS11 >100 psi 3 4 4 3 1 5 4 1-1 4 6 5 1-1 2— 3 7 7 VFPA 13, 2016 Edition, Maximum Distance Between Hangers ft—in. Jominal Pipe Size (in.) 3/4 1 1 1 /4 1 1 /2 2 2 1 /2 3 CPVC 5-6 6-0 6-6 1 7-0 1 8-0 1 9-0 1 10-0 HANGER DETAILS HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE TRIT CPVC DOUBLE FASTENER STRAP TYPE HANGER FIGURE 23 — CPVC HANGER AFCON AFCON FIG 514 U.L. LISTED CPVC/COPPER PIPE BRACKET General Notes All Pipe Locations are to be Field Measured Prior to Fabrication and Installation by Sprinkler Contractor. All Dimensions Shown are Center to Center. High Temperature Heads are to be Field Located Where Required. All Pipes and Hangers are to be Installed per NFPA #13D. Hangers are to be U.L. Listed. HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE b K FIGURE 22 — CPVC HANGER AFCON /q AFCON FIG 515 U.L. LISTED CPVC/COPPER PIPE BRACKET 0 Hydraulic Reference Points Ceiling Height Denotes Hanger Location 0 Rise up or down TABLE 8.2.5.3.2 Positioning of Sptinklcry to At•oid Obatrttctinnr to Discharge (Residential Upright and Pendent Spray Sprinklers) lfarimum ABowalik Distance of Deflector Distance from Sprinklers to Sole of Above Bottom of Obsituction (A) Obstniction (in.) (B) Less than I R (300 term) 0 1 R (300 mm) to less than 1 116 in. (450 min) 0 1 116 in. (430 min) to less than 2 ft (600 mm) 1 (25 mm) 2 ft (600 mm) to less than 2 ft 6 in. (730 nun) 1 (25 ram) 2 R (750 tam) 6 in. to less than 3 ft (900 rein) 1 (25 ram) 3 ft (900 nun) to less than 3 ft 6 in. (1050 mm) 3 (75 ram) 3 R (1050 mm) 6 in. to less than 4 ft (1200 rain) 3 (75 min) 4 R (1200 man) to less than 4 R 6 in. (1350 min) 5 (125 min) 4 R (1351) mm) 6 in. to less than 5 ft (1500 mm) 7 (175 mm) 5 R (1500 nun) to less than 5 ft 6 in. (1650 mm) 7 (175 mm) 5 R 6 in. (1650 min) to less than 6 ft (1800 ram) 7 (175 min) 6 ft (1800 mm) to less than 6 ft 6 in. (1950 mm) 9 (225 ram) 6 R 6 (1950 mm) in. to less than 7 ft (2100 mm) 11 (275 nun) 7 A and greater 14 (350 ram) Note: For A and U. refer to Figure Obstruction A Elswtlon View FIGURE 8.2..5_i.2 Positioning ojSprinkler to Amid Obstntcrion to Discharge (Residential Upright and Pendent Spray Sprinklers). OBSTRUCTION NOTES NFPA 13D Ceairg % otxtrudb„ �`� Ceititg A. 'Mal (ArID-0R in)+e1 where! D 5 30 In. (0.76 m) Elevation View / FIGURE 8.2 U.3(a) Positioning of Sprinkler to Avoid j Obstruction Against ll'alls (Residential bprighr and Pendent Spray Sprinklers). j D A Aa(D-8In.)+B Wafl whoroD 0 30 in (0.76 m) Etevationview FIGURE8.2.5.3.3(b) Positioning of Sprinkler to Avoid Obstruction Against Walls (Residential Upright atul Pendent Spn v Sprinklers). 2 OBSTRUCTION NOTES NFPA 13D BUILDING SUMMARY OCCUPANCY: R3/U CONSTRUCTION TYPE: V-B NFPA 13D 2016 EDITION DOAN RESIDENCE 1ST FLOOR AREA = 11,162 SF 1ST FLOOR -GUEST HOUSE AREA = 2,203 SF 2ND FLOOR AREA = 4033 SF LIVING AREA = 17,398 SF GARAGE & STOR., EQUIP RM = 2,043 SF COVERED ENTRY & VERABDA & PATIO = 1,626 SF 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING CONDITIONS: (1) THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED 100 FT3 (2.83 M3). (2) THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS AT THE LOWER CEILING ELEVATION. (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE TREATMENTS IS NONCOMBUSTIBLE OR LIMITED -COMBUSTIBLE MATERIAL. (4) SKYLIGHTS NOT EXCEEDING 32 FT2 (2.97 M2) SHALL BE PERMITTED TO HAVE A PLASTIC COVER. closer to the heat source. TABLE 7.5.6.3 Minimum Distances jor Onlinan, and Intermediate Temperature Residential Sprinklers From Fdge of Source to Ordinary From Edge of Source to Temperature Sprinkler Intermediate Temperature Sprinkler Beat Source in. mm in. nun Side of open or recessed fireplace 36 900 12 300 Front of recessed fireplace 60 1500 36 900 Coal- or wood -burning stove 42 1050 12 300 Kitchen range 18 450 9 229 Wall oven 18 450 9 229 Hot air flues 18 450 9 229 Uninsulated heat ducts 18 450 9 229 Uninsulated hot water pipes 12 300 6 150 Side of ceiling- or wall -mounted hot air diRusen 24 600 12 300 Front of wall -mounted hot air diffusers 36 900 18 450 Hot water heater or furnace 6 ISO 3 76 Light fixture 0 W-250 W 6 I50 3 76 250 W-499 W 12 300 6 150 Automatic Sprinkler Systems for Residential Occupancies Handbook 1016 HEAT SOURCE NOTES NFPA 13D APPROVED BY: Drawing 2nd Floor -Fire Sprinkler Piping Plan Job: Title Revisions: Date: Contract No. 22-53821 Drawn By CFP&B Scale "As Noted" Date 9.29.22 Approval By Doan Residence 53821 Ross Avenue La Quinta Ca 92253 Contractor: California Fire Protection & Backflow 647 Camino De Los Mares San Clemente, Ca 92673 Hydraulic Calculations by HydraCALC California Fire Protection 647 Camino De Los Mares San Clemente, Ca 92673 949.770.5371 Job Name Doan Residence Drawing Residence Location 53821 Ross Ave. Remote Area 1 Contract 53821 Data File Design Area 1.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 California Fire Protection Page 1 Doan Residence Date 9.30.22 HYDRAULIC DESIGN INFORMATION SHEET Name - Doan Residence Date - 9.30.22 Location - 53821 Ross Ave. Building - Residence System No. - 1 Contractor - California Fire Protection & Backflow Contract No. - 53821 Calculated By - California Fire Protection & Backflo Drawing No. - 53821 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - Res. NFPA 13D S Y S T E M D E S I G N Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) ( )Other ( )Specific Ruling Made by Date Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction Domestic Flow Added - +5 Gpm Sprinkler or Nozzle Additional Flow Added - Gpm Make Senju Model SS8464 Elevation at Highest Outlet - Feet Size K-Factor 4.9 Note: Temperature Rating 162 Calculation Gpm Required 26.45 Psi Required 46.989 BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 71.86 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.54.4 Water Supply Curve California Fire Protection Doan Residence Page 2 Date 9.30.22 City Water Supply: Demand: C1 - Static Pressure : 64.674 D1 - Elevation 11.780 C2 - Residual Pressure: 18 D2 - System Flow : 31.454 C2 - Residual Flow 500 D2 - System Pressure 54.266 Hose ( Demand ) D3 - System Demand : 31.454 Safety Margin 10.128 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 E 50 40 30 20 10 50 100 150 200 250 300 350 400 450 FLOW (N " 1.85) C2 Computer Programs by Hydratec Inc. Revision: 50.54.4 Fittings Used Summary California Fire Protection Doan Residence Page 3 Date 9.30.22 Fitting Legend Abbrev. Name 'h % 1 14 1'/2 2 2'h 3 3'h 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 N' CPVC 90'EII Harvel-Spears 0 2.0 2.5 3.8 4 5.7 6.9 7.9 0 0 0 0 0 0 0 0 0 0 0 0 O* CPVC Tee - Branch 0 4.9 6 7.3 8.4 12.0 14.7 16.4 0 0 0 0 0 0 0 0 0 0 0 0 R' CPVC Coupling Tee - Run 0 1 1.7 2.6 2.7 4 4.9 6.1 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.54.4 Pressure / Flow Summary - STANDARD California Fire Protection Page 4 Doan Residence Date 9.30.22 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SRP1 23.7 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 24.2 6.91 na SRP2 23.7 4.9 7.04 na 13.0 0.05 256 7.039 EQ=2 24.2 7.02 na H1 24.2 K = K @ EQ=2 7.52 na 13.45 1 24.2 9.53 na 2 24.2 10.87 na 3 24.2 12.5 na 4 12.6 19.13 na 5 12.6 20.68 na 6 12.6 28.92 na 7 10.6 30.3 na H2 24.2 K = K @ EQ=1 6.91 na 13.0 1.1 24.2 7.52 na 1.2 24.2 8.33 na 1.3 24.2 9.3 na 1.4 24.2 10.35 na 1.5 24.2 11.34 na TOR 10.6 42.38 na BOR 2.0 46.99 na 5.0 UG1 -3.0 49.95 na METE -3.0 53.07 na TEST -3.0 54.27 na The maximum velocity is 8.91 and it occurs in the pipe between nodes 3 and 4 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 5 Doan Residence Date 9.30.22 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 23.700 4.90 13.00 1 N 2.5 0.500 150 7.039 to 2.500 -0.217 EQ=1 24.200 13.0 1.101 3.000 0.0307 0.092 Vel = 4.38 0.0 EQ=1 13.00 6.914 K Factor = 4.94 SRP2 23.700 4.90 13.00 1 O 6.0 0.500 150 7.039 to 6.000 -0.217 EQ=2 24.200 13.0 1.101 6.500 0.0308 0.200 Vel = 4.38 0.0 EQ=2 13.00 7.022 K Factor = 4.91 H 1 24.200 4.91 13.05 1 5R 8.5 50.667 150 7.520 K = K @ EQ=2 to O 6.0 14.500 0.0 1 24.200 13.05 1.101 65.167 0.0309 2.012 Vel = 4.40 1 24.200 0.0 1 5R 8.5 32.417 150 9.532 to N 2.5 11.000 0.0 2 24.200 13.05 1.101 43.417 0.0309 1.341 Vel = 4.40 2 24.200 0.0 1 6R 10.2 34.167 150 10.873 to N 2.5 18.700 0.0 3 24.200 13.05 1.101 O 6.0 52.867 0.0309 1.632 Vel = 4.40 3 24.200 13.40 1 N 2.5 11.500 150 12.505 to 2.500 5.024 4 12.600 26.45 1.101 14.000 0.1141 1.598 Vel = 8.91 4 12.600 0.0 1 O 6.0 7.583 150 19.127 to 6.000 0.0 5 12.600 26.45 1.101 13.583 0.1141 1.550 Vel = 8.91 5 12.600 0.0 1 2R 3.4 66.333 150 20.677 to N 2.5 5.900 0.0 6 12.600 26.45 1.101 72.233 0.1142 8.246 Vel = 8.91 6 12.600 0.0 1 N 2.5 2.000 150 28.923 to 2.500 0.866 7 10.600 26.45 1.101 4.500 0.1140 0.513 Vel = 8.91 7 10.600 0.0 1 9R 15.3 88.000 150 30.302 to N 2.5 17.800 0.0 TOR 10.600 26.45 1.101 105.800 0.1141 12.077 Vel = 8.91 0.0 TOR 26.45 42.379 K Factor = 4.06 H2 24.200 4.94 13.00 1 N 2.5 11.250 150 6.914 K = K @ EQ=1 to O 6.0 8.500 0.0 1.1 24.200 13.0 1.101 19.750 0.0307 0.606 Vel = 4.38 1.1 24.200 0.41 1 R 1.7 17.333 150 7.520 to O 6.0 7.700 0.0 1.2 24.200 13.41 1.101 25.033 0.0325 0.813 Vel = 4.52 1.2 24.200 0.0 1 R 1.7 22.083 150 8.333 to O 6.0 7.700 0.0 1.3 24.200 13.41 1.101 29.783 0.0324 0.966 Vel = 4.52 1.3 24.200 0.0 1 3R 5.1 21.333 150 9.299 to O 6.0 11.100 0.0 1.4 24.200 13.41 1.101 32.433 0.0325 1.053 Vel = 4.52 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 6 Doan Residence Date 9.30.22 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1.4 24.200 0.0 1 R 1.7 22.833 150 10.352 to O 6.0 7.700 0.0 1.5 24.200 13.41 1.101 30.533 0.0325 0.991 Vel = 4.52 1.5 24.200 0.0 1 R 1.7 25.583 150 11.343 to N 2.5 10.200 0.0 3 24.200 13.41 1.101 O 6.0 35.783 0.0325 1.162 Vel = 4.52 0.0 3 13.41 12.505 K Factor = 3.79 1.1 24.200 -0.41 1 R 1.7 0.667 150 7.520 to 1.700 0.0 H 1 24.200 -0.41 1.101 2.367 0 0.0 Vel = 0.14 0.0 H 1 -0.41 7.520 K Factor = -0.15 TOR 10.600 26.45 1.25 S 11.11 8.600 150 42.379 to E 4.762 15.871 3.725 BOR 2 26.45 1.394 24.471 0.0362 0.885 Vel = 5.56 BOR 2 + 5.00 5.00 1.25 2E 5.935 4.000 150 46.989 to 5.935 2.166 UG1 -3 31.45 1.265 9.935 0.0799 0.794 Vel = 8.03 UG1 -3 0.0 2 F 3.022 150.000 150 49.949 to 3.022 2.000 * " Fixed Loss = 2 METE -3 31.45 2.067 153.022 0.0073 1.120 Vel = 3.01 METE -3 0.0 2 126.000 150 53.069 to 0.0 TEST -3 31.45 1.959 126.000 0.0095 1.197 Vel = 3.35 0.0 TEST 31.45 54.266 K Factor = 4.27 Computer Programs by Hydratec Inc. Revision: 50.54.4 Hydraulic Calculations by HydraCALC California Fire Protection 647 Camino De Los Mares San Clemente, Ca 92673 949.770.5371 Job Name Doan Residence Drawing Residence Location 53821 Ross Ave. Remote Area 2 Contract 53821 Data File Design Area 2.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 California Fire Protection Page 1 Doan Residence Date 9.30.22 HYDRAULIC DESIGN INFORMATION SHEET Name - Doan Residence Date - 9.30.22 Location - 53821 Ross Ave. Building - Residence System No. - 2 Contractor - California Fire Protection & Backflow Contract No. - 53821 Calculated By - California Fire Protection & Backflo Drawing No. - 53821 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - Res. NFPA 13D S Y S T E M D E S I G N Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: (x)1 ( )2 ( )4 ( ) ( )Other ( )Specific Ruling Made by Date Listed Flow at Start Point - 21 Gpm System Type Listed Pres. at Start Point - 18.4 Psi (X) Wet ( ) Dry MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction Domestic Flow Added - +5 Gpm Sprinkler or Nozzle Additional Flow Added - Gpm Make Senju Model SS8464 Elevation at Highest Outlet - Feet Size K-Factor 4.9 Note: Temperature Rating 162 Calculation Gpm Required 21.02 Psi Required 49.533 BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 71.86 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.54.4 Water Supply Curve California Fire Protection Doan Residence Page 2 Date 9.30.22 City Water Supply: Demand: C1 - Static Pressure : 64.674 D1 - Elevation 11.780 C2 - Residual Pressure: 18 D2 - System Flow : 26.019 C2 - Residual Flow 500 D2 - System Pressure 55.889 Hose ( Demand ) D3 - System Demand : 26.019 Safety Margin 8.588 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 E 50 40 30 20 10 50 100 150 200 250 300 350 400 450 FLOW (N " 1.85) C2 Computer Programs by Hydratec Inc. Revision: 50.54.4 Fittings Used Summary California Fire Protection Doan Residence Page 3 Date 9.30.22 Fitting Legend Abbrev. Name 'h % 1 14 1'/2 2 2'h 3 3'h 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 N' CPVC 90'EII Harvel-Spears 0 2.0 2.5 3.8 4 5.7 6.9 7.9 0 0 0 0 0 0 0 0 0 0 0 0 O* CPVC Tee - Branch 0 4.9 6 7.3 8.4 12.0 14.7 16.4 0 0 0 0 0 0 0 0 0 0 0 0 R' CPVC Coupling Tee - Run 0 1 1.7 2.6 2.7 4 4.9 6.1 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.54.4 Pressure / Flow Summary - STANDARD California Fire Protection Page 4 Doan Residence Date 9.30.22 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SRP1 23.7 4.9 18.4 na 21.02 0.05 400 18.4 EQ=1 24.2 18.41 na H3 24.2 K = K @ EQ=1 18.41 na 21.02 2.1 24.2 19.81 na H1 24.2 21.52 na 1 24.2 22.38 na 2 24.2 22.96 na 3 24.2 23.67 na 4 12.6 29.74 na 5 12.6 30.75 na 6 12.6 36.14 na 7 10.6 37.34 na 1.1 24.2 21.48 na 1.2 24.2 21.15 na 1.3 24.2 20.75 na 1.4 24.2 21.71 na 1.5 24.2 22.61 na TOR 10.6 45.23 na BOR 2.0 49.53 na 5.0 UG1 -3.0 52.26 na METE -3.0 55.05 na TEST -3.0 55.89 na The maximum velocity is 7.08 and it occurs in the pipe between nodes SRP1 and EQ=1 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 5 Doan Residence Date 9.30.22 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 23.700 4.90 21.02 1 N 2.5 0.500 150 18.400 to 2.500 -0.217 EQ=1 24.200 21.02 1.101 3.000 0.0747 0.224 Vel = 7.08 0.0 EQ=1 21.02 18.407 K Factor = 4.90 H3 24.200 4.9 21.02 1 O 6.0 12.833 150 18.407 K = K @ EQ=1 to 6.000 0.0 2.1 24.200 21.02 1.101 18.833 0.0746 1.405 Vel = 7.08 2.1 24.200 0.0 1 R 1.7 4.917 150 19.812 to O 6.0 7.700 0.0 1.3 24.200 21.02 1.101 12.617 0.0746 0.941 Vel = 7.08 0.0 1.3 21.02 20.753 K Factor = 4.61 H 1 24.200 8.29 1 5R 8.5 50.667 150 21.515 to O 6.0 14.500 0.0 1 24.200 8.29 1.101 65.167 0.0133 0.869 Vel = 2.79 1 24.200 0.0 1 5R 8.5 32.417 150 22.384 to N 2.5 11.000 0.0 2 24.200 8.29 1.101 43.417 0.0133 0.578 Vel = 2.79 2 24.200 0.0 1 6R 10.2 34.167 150 22.962 to N 2.5 18.700 0.0 3 24.200 8.29 1.101 O 6.0 52.867 0.0133 0.705 Vel = 2.79 3 24.200 12.73 1 N 2.5 11.500 150 23.667 to 2.500 5.024 4 12.600 21.02 1.101 14.000 0.0746 1.044 Vel = 7.08 4 12.600 0.0 1 O 6.0 7.583 150 29.735 to 6.000 0.0 5 12.600 21.02 1.101 13.583 0.0747 1.014 Vel = 7.08 5 12.600 0.0 1 2R 3.4 66.333 150 30.749 to N 2.5 5.900 0.0 6 12.600 21.02 1.101 72.233 0.0746 5.387 Vel = 7.08 6 12.600 0.0 1 N 2.5 2.000 150 36.136 to 2.500 0.866 7 10.600 21.02 1.101 4.500 0.0747 0.336 Vel = 7.08 7 10.600 0.0 1 9R 15.3 88.000 150 37.338 to N 2.5 17.800 0.0 TOR 10.600 21.02 1.101 105.800 0.0746 7.892 Vel = 7.08 0.0 TOR 21.02 45.230 K Factor = 3.13 1.1 24.200 -8.29 1 R 1.7 17.333 150 21.484 to O 6.0 7.700 0.0 1.2 24.200 -8.29 1.101 25.033 -0.0133 -0.334 Vel = 2.79 1.2 24.200 0.0 1 R 1.7 22.083 150 21.150 to O 6.0 7.700 0.0 1.3 24.200 -8.29 1.101 29.783 -0.0133 -0.397 Vel = 2.79 1.3 24.200 21.02 1 3R 5.1 21.333 150 20.753 to O 6.0 11.100 0.0 1.4 24.200 12.73 1.101 32.433 0.0295 0.957 Vel = 4.29 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 6 Doan Residence Date 9.30.22 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1.4 24.200 0.0 1 R 1.7 22.833 150 21.710 to O 6.0 7.700 0.0 1.5 24.200 12.73 1.101 30.533 0.0295 0.901 Vel = 4.29 1.5 24.200 0.0 1 R 1.7 25.583 150 22.611 to N 2.5 10.200 0.0 3 24.200 12.73 1.101 O 6.0 35.783 0.0295 1.056 Vel = 4.29 0.0 3 12.73 23.667 K Factor = 2.62 1.1 24.200 8.29 1 R 1.7 0.667 150 21.484 to 1.700 0.0 H 1 24.200 8.29 1.101 2.367 0.0131 0.031 Vel = 2.79 0.0 H 1 8.29 21.515 K Factor = 1.79 TOR 10.600 21.02 1.25 S 11.11 8.600 150 45.230 to E 4.762 15.871 3.725 BOR 2 21.02 1.394 24.471 0.0236 0.578 Vel = 4.42 BOR 2 + 5.00 5.00 1.25 2E 5.935 4.000 150 49.533 to 5.935 2.166 UG1 -3 26.02 1.265 9.935 0.0563 0.559 Vel = 6.64 UG1 -3 0.0 2 F 3.022 150.000 150 52.258 to 3.022 2.000 * " Fixed Loss = 2 METE -3 26.02 2.067 153.022 0.0051 0.788 Vel = 2.49 METE -3 0.0 2 126.000 150 55.046 to 0.0 TEST -3 26.02 1.959 126.000 0.0067 0.843 Vel = 2.77 0.0 TEST 26.02 55.889 K Factor = 3.48 Computer Programs by Hydratec Inc. Revision: 50.54.4 Hydraulic Calculations by HydraCALC California Fire Protection 647 Camino De Los Mares San Clemente, Ca 92673 949.770.5371 Job Name Doan Residence Drawing Residence Location 53821 Ross Ave. Remote Area 3 Contract 53821 Data File Design Area 3.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 California Fire Protection Page 1 Doan Residence Date 9.30.22 HYDRAULIC DESIGN INFORMATION SHEET Name - Doan Residence Date - 9.30.22 Location - 53821 Ross Ave. Building - Residence System No. - 3 Contractor - California Fire Protection & Backflow Contract No. - 53821 Calculated By - California Fire Protection & Backflo Drawing No. - 53821 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - Res. NFPA 13D S Y S T E M D E S I G N Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) ( )Other ( )Specific Ruling Made by Date Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction Domestic Flow Added - +5 Gpm Sprinkler or Nozzle Additional Flow Added - Gpm Make Senju Model SS8464 Elevation at Highest Outlet - Feet Size K-Factor 4.9 Note: Temperature Rating 162 Calculation Gpm Required 26 Psi Required 52.130 BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 71.86 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.54.4 Water Supply Curve California Fire Protection Doan Residence Page 2 Date 9.30.22 City Water Supply: Demand: C1 - Static Pressure : 64.674 D1 - Elevation 6.756 C2 - Residual Pressure: 18 D2 - System Flow : 31.003 C2 - Residual Flow 500 D2 - System Pressure 59.325 Hose ( Demand ) D3 - System Demand : 31.003 Safety Margin 5.077 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 R 60 E 50 40 30 20 10 D1 50 100 150 200 250 300 350 400 450 FLOW (N " 1.85) C2 Computer Programs by Hydratec Inc. Revision: 50.54.4 Fittings Used Summary California Fire Protection Doan Residence Page 3 Date 9.30.22 Fitting Legend Abbrev. Name 'h % 1 14 1'/2 2 2'h 3 3'h 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 N' CPVC 90'EII Harvel-Spears 0 2.0 2.5 3.8 4 5.7 6.9 7.9 0 0 0 0 0 0 0 0 0 0 0 0 O* CPVC Tee - Branch 0 4.9 6 7.3 8.4 12.0 14.7 16.4 0 0 0 0 0 0 0 0 0 0 0 0 R' CPVC Coupling Tee - Run 0 1 1.7 2.6 2.7 4 4.9 6.1 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.54.4 Pressure / Flow Summary - STANDARD California Fire Protection Page 4 Doan Residence Date 9.30.22 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SRP1 12.1 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 12.6 6.91 na H4 12.6 K = K @ EQ=1 6.92 na 13.0 101 12.6 7.28 na 102 12.6 9.7 na 103 10.6 11.06 na 104 10.6 16.12 na 105 10.6 18.14 na 106 12.6 17.77 na 107 12.6 23.19 na 5 12.6 26.5 na 6 12.6 34.49 na 7 10.6 35.85 na H5 12.6 K = K @ EQ=1 6.91 na 13.0 TOR 10.6 47.55 na BOR 2.0 52.13 na 5.0 UG1 -3.0 55.07 na METE -3.0 58.16 na TEST -3.0 59.32 na The maximum velocity is 8.76 and it occurs in the pipe between nodes 101 and 102 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 5 Doan Residence Date 9.30.22 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 12.100 4.90 13.00 1 N 2.5 0.500 150 7.039 to 2.500 -0.217 EQ=1 12.600 13.0 1.101 3.000 0.0307 0.092 Vel = 4.38 0.0 EQ=1 13.00 6.914 K Factor = 4.94 H4 12.600 4.94 13.00 1 O 6.0 5.917 150 6.917 K = K @ EQ=1 to 6.000 0.0 101 12.600 13.0 1.101 11.917 0.0306 0.365 Vel = 4.38 101 12.600 13.00 1 R 1.7 17.667 150 7.282 to N 2.5 4.200 0.0 102 12.600 26.0 1.101 21.867 0.1106 2.418 Vel = 8.76 102 12.600 0.0 1 N 2.5 2.000 150 9.700 to 2.500 0.866 103 10.600 26.0 1.101 4.500 0.1107 0.498 Vel = 8.76 103 10.600 0.0 1 4R 6.8 32.917 150 11.064 to O 6.0 12.800 0.0 104 10.600 26.0 1.101 45.717 0.1106 5.055 Vel = 8.76 104 10.600 0.0 1 2R 3.4 12.333 150 16.119 to N 2.5 5.900 0.0 105 10.600 26.0 1.101 18.233 0.1106 2.016 Vel = 8.76 105 10.600 0.0 1 N 2.5 2.000 150 18.135 to 2.500 -0.866 106 12.600 26.0 1.101 4.500 0.1107 0.498 Vel = 8.76 106 12.600 0.0 1 3R 5.1 37.917 150 17.767 to O 6.0 11.100 0.0 107 12.600 26.0 1.101 49.017 0.1106 5.420 Vel = 8.76 107 12.600 0.0 1 R 1.7 22.250 150 23.187 to O 6.0 7.700 0.0 5 12.600 26.0 1.101 29.950 0.1106 3.311 Vel = 8.76 5 12.600 0.0 1 2R 3.4 66.333 150 26.498 to N 2.5 5.900 0.0 6 12.600 26.0 1.101 72.233 0.1106 7.987 Vel = 8.76 6 12.600 0.0 1 N 2.5 2.000 150 34.485 to 2.500 0.866 7 10.600 26.0 1.101 4.500 0.1107 0.498 Vel = 8.76 7 10.600 0.0 1 9R 15.3 88.000 150 35.849 to N 2.5 17.800 0.0 TOR 10.600 26.0 1.101 105.800 0.1106 11.699 Vel = 8.76 0.0 TOR 26.00 47.548 K Factor = 3.77 H5 12.600 4.94 13.00 1 O 6.0 6.000 150 6.914 K = K @ EQ=1 to 6.000 0.0 101 12.600 13.0 1.101 12.000 0.0307 0.368 Vel = 4.38 0.0 101 13.00 7.282 K Factor = 4.82 TOR 10.600 26.00 1.25 S 11.11 8.600 150 47.548 to E 4.762 15.871 3.725 BOR 2 26.0 1.394 24.471 0.0350 0.857 Vel = 5.47 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 6 Doan Residence Date 9.30.22 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf BOR 2 + 5.00 5.00 1.25 2E 5.935 4.000 150 52.130 to 5.935 2.166 UG1 -3 31.0 1.265 9.935 0.0778 0.773 Vel = 7.91 UG1 -3 0.0 2 F 3.022 150.000 150 55.069 to 3.022 2.000 * * Fixed Loss = 2 METE -3 31.0 2.067 153.022 0.0071 1.090 Vel = 2.96 METE -3 0.0 2 126.000 150 58.159 to 0.0 TEST -3 31.0 1.959 126.000 0.0093 1.166 Vel = 3.30 0.0 TEST 31.00 59.325 K Factor = 4.02 Computer Programs by Hydratec Inc. Revision: 50.54.4 Hydraulic Calculations by HydraCALC California Fire Protection 647 Camino De Los Mares San Clemente, Ca 92673 949.770.5371 Job Name Doan Residence Drawing Residence Location 53821 Ross Ave. Remote Area 3 Contract 53821 Data File Design Area 3.WXF Computer Programs by Hydratec Inc. Revision: 50.54.4 California Fire Protection Page 1 Doan Residence Date 5.3.23 HYDRAULIC DESIGN INFORMATION SHEET Name - Doan Residence Date - 5.3.23 Location - 53821 Ross Ave. Building - Residence System No. - 3 Contractor - California Fire Protection & Backflow Contract No. - 53821 Calculated By - California Fire Protection & Backflo Drawing No. - 53821 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - Res. NFPA 13D S Y S T E M D E S I G N Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) ( )Other ( )Specific Ruling Made by Date Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction Domestic Flow Added - +5 Gpm Sprinkler or Nozzle Additional Flow Added - Gpm Make Senju Model SS8464 Elevation at Highest Outlet - Feet Size K-Factor 4.9 Note: Temperature Rating 162 Calculation Gpm Required 26 Psi Required 55.931 BOR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 71.86 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Revision: 50.54.4 Water Supply Curve California Fire Protection Doan Residence Page 2 Date 5.3.23 City Water Supply: Demand: C1 - Static Pressure : 64.674 D1 - Elevation 6.756 C2 - Residual Pressure: 18 D2 - System Flow : 31.003 C2 - Residual Flow 500 D2 - System Pressure 62.547 Hose ( Demand ) D3 - System Demand : 31.003 Safety Margin 1.855 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 2 R 60 E 50 40 30 20 10 D1 50 100 150 200 250 300 350 400 450 FLOW (N " 1.85) C2 Computer Programs by Hydratec Inc. Revision: 50.54.4 Fittings Used Summary California Fire Protection Doan Residence Page 3 Date 5.3.23 Fitting Legend Abbrev. Name 'h 3/4 1 14 1'/2 2 2'h 3 3'h 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 N' CPVC 90' - Elbow 0 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 O* CPVC Tee - Branch 0 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R' CPVC Coupling Tee - Run 0 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.54.4 Pressure / Flow Summary - STANDARD California Fire Protection Page 4 Doan Residence Date 5.3.23 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. SRP1 12.1 4.9 7.04 na 13.0 0.05 256 7.039 EQ=1 12.6 7.05 na H4 12.6 K = K @ EQ=1 7.05 na 13.0 101 12.6 7.39 na 102 12.6 10.34 na 103 10.6 12.2 na 104 10.6 16.46 na 105 10.6 20.0 na 106 12.6 20.12 na 107 12.6 25.78 na 108 10.6 27.64 na 109 10.6 28.26 na 110 12.6 30.15 na 6 12.6 31.14 na 7 12.6 39.3 na 8 10.6 41.16 na 9 10.6 50.52 na H5 12.6 K = K @ EQ=1 7.05 na 13.0 TOR 10.6 51.24 na BOR 2.0 55.93 na 5.0 UG1 -3.0 58.24 na METE -3.0 61.38 na TEST -3.0 62.55 na The maximum velocity is 8.76 and it occurs in the pipe between nodes 101 and 102 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 5 Doan Residence Date 5.3.23 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SRP1 12.100 4.90 13.00 1 N 7.0 0.500 150 7.039 to 7.000 -0.217 EQ=1 12.600 13.0 1.101 7.500 0.0307 0.230 Vel = 4.38 0.0 EQ=1 13.00 7.052 K Factor = 4.90 H4 12.600 4.9 13.00 1 O 5.0 5.917 150 7.055 K = K @ EQ=1 to 5.000 0.0 101 12.600 13.0 1.101 10.917 0.0307 0.335 Vel = 4.38 101 12.600 13.00 1 2R 2.0 17.667 150 7.390 to N 7.0 9.000 0.0 102 12.600 26.0 1.101 26.667 0.1105 2.948 Vel = 8.76 102 12.600 0.0 1 N 7.0 2.000 150 10.338 to 7.000 0.866 103 10.600 26.0 1.101 9.000 0.1107 0.996 Vel = 8.76 103 10.600 0.0 1 3R 3.0 30.500 150 12.200 to O 5.0 8.000 0.0 104 10.600 26.0 1.101 38.500 0.1106 4.257 Vel = 8.76 104 10.600 0.0 1 2R 2.0 16.000 150 16.457 to 2N 14.0 16.000 0.0 105 10.600 26.0 1.101 32.000 0.1106 3.538 Vel = 8.76 105 10.600 0.0 1 N 7.0 2.000 150 19.995 to 7.000 -0.866 106 12.600 26.0 1.101 9.000 0.1106 0.995 Vel = 8.76 106 12.600 0.0 1 3R 3.0 41.167 150 20.124 to N 7.0 10.000 0.0 107 12.600 26.0 1.101 51.167 0.1106 5.658 Vel = 8.76 107 12.600 0.0 1 N 7.0 2.000 150 25.782 to 7.000 0.866 108 10.600 26.0 1.101 9.000 0.1106 0.995 Vel = 8.76 108 10.600 0.0 1 O 5.0 0.583 150 27.643 to 5.000 0.0 109 10.600 26.0 1.101 5.583 0.1107 0.618 Vel = 8.76 109 10.600 0.0 1 O 5.0 19.917 150 28.261 to 5.000 -0.866 110 12.600 26.0 1.101 24.917 0.1106 2.755 Vel = 8.76 110 12.600 0.0 1 O 5.0 4.000 150 30.150 to 5.000 0.0 6 12.600 26.0 1.101 9.000 0.1106 0.995 Vel = 8.76 6 12.600 0.0 1 4R 4.0 62.750 150 31.145 to N 7.0 11.000 0.0 7 12.600 26.0 1.101 73.750 0.1106 8.155 Vel = 8.76 7 12.600 0.0 1 N 7.0 2.000 150 39.300 to 7.000 0.866 8 10.600 26.0 1.101 9.000 0.1106 0.995 Vel = 8.76 8 10.600 0.0 1 8R 8.0 76.667 150 41.161 to 8.000 0.0 9 10.600 26.0 1.101 84.667 0.1106 9.362 Vel = 8.76 9 10.600 0.0 1.25 R 1.0 11.333 150 50.523 to N 8.0 9.000 0.0 TOR 10.600 26.0 1.394 20.333 0.0350 0.712 Vel = 5.47 Computer Programs by Hydratec Inc. Revision: 50.54.4 Final Calculations: Hazen -Williams California Fire Protection Page 6 Doan Residence Date 5.3.23 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 TOR 26.00 51.235 K Factor = 3.63 H5 12.600 4.9 13.00 1 O 5.0 6.000 150 7.052 K = K @ EQ=1 to 5.000 0.0 101 12.600 13.0 1.101 11.000 0.0307 0.338 Vel = 4.38 0.0 101 13.00 7.390 K Factor = 4.78 TOR 10.600 26.00 1.25 S 11.11 8.600 150 51.235 to N 8.0 19.110 3.725 BOR 2 26.0 1.394 27.710 0.0350 0.971 Vel = 5.47 BOR 2 + 5.00 5.00 2 2E 12.407 4.000 150 55.931 to 12.407 2.166 UG1 -3 31.0 1.985 16.407 0.0087 0.142 Vel = 3.21 UG1 -3 0.0 2 F 2.882 150.000 150 58.239 to 2.882 2.000 * * Fixed Loss = 2 METE -3 31.0 2.047 152.882 0.0075 1.142 Vel = 3.02 METE -3 0.0 2 126.000 150 61.381 to 0.0 TEST -3 31.0 1.959 126.000 0.0093 1.166 Vel = 3.30 0.0 TEST 31.00 62.547 K Factor = 3.92 Computer Programs by Hydratec Inc. Revision: 50.54.4