Loading...
BRES2018-0353Permit Details City of La Quinta PERMIT NUMBER BRES2018-0353 Description: CASA CHI LLC/2,4405F SFD W/ CASITA / VB/RES-3/CLASS A-FR/13D Type: BUILDING RESIDENTIAL Subtype: DWELLING - SINGLE Status: FINALED (WEB) FAMILY DETACHED Applied: 11/6/2018 AMA Approved: 6/11/2020 JFU Issued: 6/30/2020 SSW Finaled: 4/11/2022 JFU Expired: Parcel No: 774041001 Site Address: 77285 CALLE CHIHUAHUA LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 178 Lot: 24 UNIT 18 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $153,450.10 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: CASA CHI LLC / 2,4405F DWELLING W/ CASITA (MAIN HOUSE 2,112SF + CASITA 328SF) [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. REVISION 2 - UPDATED FENESTRATION VALUES, ADDED HVAC SYSTEM AND NEW HVAC CLOSET. (REVISION 1 WITHDRAWN AND INCORPORATED INTO REVISION 2). Process Summary 650 19 583 Applied to Approved Approved to Issued Issued to Finaled ADDITIONAL SITES CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL JAKE FUSON 8/21/2019 8/21/2019 SENT 3RD REVIEW CORRECTIONS TO ISH CORONEL AND EXPLAINED TO HIM THAT ANY RESUBMITTAL MUST BE A COMPLETE RESUBMITTAL OF ALL PLANS AND DOCUMENTS AS ONLY A PRECISE GRADING PLAN WAS SUBMITTED FOR THIS 3RD REVIEW. E-MAIL JAKE FUSON 3/3/2020 3/3/2020 NOTIFIED ISH CORONEL OF 4TH REVIEW CORRECTIONS AND ALL REMAINING ITEMS REQUIRED FOR PERMIT ISSUANCE. E-MAIL JAKE FUSON 6/11/2020 6/11/2020 NOTIFIED ISH CORONEL THAT PLANS ARE APPROVED AND PERMIT IS READY TO ISSUE PENDING RESOLUTION OF CONDITIONS FOR ISSUANCE (SEE CONDITIONS TAB). E-MAIL JAKE FUSON 12/9/2020 12/9/2020 NOTIFIED ISH CORONEL OF REVISION 2 COMMENTS. E-MAIL JAKE FUSON 12/17/2020 12/17/2020 NOTIFIED GABRIEL RIOS AND ISH CORONEL THAT REVISION 2 PLANS ARE APPROVED AND READY FOR FEE PAYMENT. Printed: Thursday, July 27, 2023 5:05:55 PM 1 of 23 CRI f'SYSTEMS Permit Details City of La Quinta PERMIT NUMBER BRE52018-03 PLAN CHECK COMMENTS FROM CONSULTANT RECEIVED AARON HICKSON 11/28/2018 11/28/2018 RECEIVED REVISIONS REQUESTED PLAN CHECK PICKED UP AARON HICKSON 12/19/2018 12/19/2018 GABRIEL RIOS PICKED UP PLAN CHECK PLAN CHECK PICKED UP AARON HICKSON 12/3/2019 12/3/2019 ISH CORONEL CAME IN TO SUBMIT PARCEL MERGER AND PRECISE GRADING .ACCORDING TO NOTES BY JF ONLY TAKE IN FULL SUBMITTAL WITH PRECISE CORRECTIONS IN PLAN SET.ISH CORNEL PICKED UP PLAN CHECK. HE DID NOT REALIZE 2ND PC WAS NEVER PICKED UP. INFORMED HIM TO BRING IN A LETTER FROM OWNER ASSIGNEING HIM AS CONTRACTOR. PLAN CHECK PICKED UP JACK LIMA 3/3/2020 3/3/2020 4TH PLAN REVIEW PICKED UP BY ISH CORONEL. RESUBMITTAL AARON HICKSON 1/31/2020 1/31/2020 RESUBMITTAL AJ ORTEGA 6/10/2020 6/10/2020 REVIEWED ATTACHMENTS (NOT FOR 4TH REVIEW COMMENTS), RENAMED FILE NAME AND DESCRIPTION, CREATED REVIEW. RESUBMITTAL JAKE FUSON 12/15/2020 12/15/2020 REVISION 2 - 2ND SUBMITTAL RECEIVED 12/15/2020. RESUBMITTAL JACK LIMA 5/8/2019 5/9/2019 PLANS SUBMITTED BY GABRIEL RIOS. CHECKED WITH A.J. AND WE WILL KEEP THESE IN HOUSE. SUBMITTAL AJ ORTEGA 10/1/2020 10/1/2020 REVISION DETERMINED INCOMPLETE, NO PLANS WERE UPLOADED WITH ENERGY COMPLIANCE REPORT, AND IT IS UNREGISTERED, EMAIL SENT TO CONTRACTOR AND APPLICANT. SUBMITTAL JACK LIMA 8/1/2019 8/1/2019 PRECISE GRADING PLANS SUBMITTED BY ISH CORONEL. TELEPHONE CALL JAKE FUSON 5/16/2019 5/16/2019 NOTIFIED GABRIEL RIOS OF CORRECTIONS FROM 2ND REVIEW. CONDITIONS CONDITION TYPE CONTACT DATE ADDED DATE REQUIRED DATE SATISFIED STATUS REMARKS NOTES READY TO ISSUE CHECKLIST AJ ORTEGA 12/3/2018 6/30/2020 COMPLETE PARCEL MERGER PMER2019-0001 IS RECORDED AND ATTACHED Printed: Thursday, July 27, 2023 5:05:55 PM 2 of 23 CRWSYSTEMS Permit Details City of La Quinta PERMIT NUMBER BRE52018-035 0 READY TO ISSUE CHECKLIST AJ ORTEGA 12/3/2018 6/30/2020 COMPLETE THE FOLLOWING ARE REQUIRED PRIOR TO ISSUANCE: -SCHOOL FEE RECEIPT -WASTE MANAGEMENT PLAN -GRANT DEED ALL OUTSTANDING ITEMS RECEIVED. CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT GABRIEL RIOS 49901 CINNABAR LN COACHELLA CA 92236 RIOSDESIGNS@YAHOO .COM CONTRACTOR CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO CA 92201 ISH@CORONELENT.CO M OWNER WILSON JACK M & MAJEL A 77285 CALLE CHIHUAHUA LA QUINTA CA 92253 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY RE -INSPECTION FEE 101-0000-42400 0 $83.37 $83.37 4/8/22 WEB11352 636500522 46 CREDIT CORONEL ENTERPRISES INC ECON Total Paid for ADMINISTRATIVE: $83.37 $83.37 HOURLY CHARGE CITY BUILDING STAFF 101-0000-42600 0.75 $120.00 $120.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW HOURLY CHARGE CITY BUILDING STAFF 101-0000-42600 1 $161.00 $161.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW HOURLY CHARGE CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 $80.50 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW HOURLY CHARGE CITY BUILDING STAFF 101-0000-42600 1.5 $241.50 $241.50 12/17/20 WEB6994 01991G CREDIT CORONEL ENTERPRISES INC ECON Total Paid for BLDG CITY STAFF - PER HOUR: $603.00 $603.00 Printed: Thursday, July 27, 2023 5:05:55 PM 3 of 23 CRWSYSTEMS Permit Details PERMIT NUMBER City of La Quinta BRES2018-0353 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $7.00 $7.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for BUILDING STANDARDS ADMINISTRATION $7.00 $7.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF PARK MAINTENANCE 256-0000-43200 0 $40.00 $40.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF STREET MAINTENANCE 255-0000-43200 0 $116.00 $116.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $26.68 $26.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW TEMP POWER SERVICE PC 101-0000-42600 0 $18.68 $18.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for ELECTRICAL: $45.36 $45.36 RESIDENTIAL, EA ADDITION 1,0005F 101-0000-42403 0 $27.22 $27.22 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Printed: Thursday, July 27, 2023 5:05:55 PM 4 of 23 CRWSYSTE S Permit Details PERMIT NUMBER City of La Quinta BRES2018-0353 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ PAID BY CLTD BY RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $11.20 $11.20 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 $160.10 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 $52.83 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for ELECTRICAL - NEW CONSTRUCTION: $251.35 $251.35 RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF 101-0000-42408 0 $40.02 $40.02 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC 101-0000-42600 0 $200.12 $200.12 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for GRADING: $240.14 $240.14 AIR HANDLER 101-0000-42402 0 $40.02 $40.02 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW AIR HANDLER PC 101-0000-42600 0 $13.34 $13.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW CONDENSER/COMPRES SOR 101-0000-42402 0 $80.04 $80.04 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW CONDENSER/COMPRES SOR PC 101-0000-42600 0 $53.36 $53.36 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW EXHAUST HOOD 101-0000-42402 0 $13.34 $13.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW EXHAUST HOOD PC 101-0000-42600 0 $5.34 $5.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW FURNACE 101-0000-42402 0 $40.02 $40.02 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW FURNACE PC 101-0000-42600 0 $26.68 $26.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Printed: Thursday, July 27, 2023 5:05:55 PM 5 of 23 CRWSYSTEMS Permit Details PERMIT NUMBER City of La Quinta BRES2018-0353 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ PAID BY CLTD BY VENT FAN 101-0000-42402 0 $80.04 $80.04 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW VENT FAN PC 101-0000-42600 0 $32.04 $32.04 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for MECHANICAL: $384.22 $384.22 MULTI SPECIES RESIDENTIAL 0-8 UNITS - 2019 UPDATE 101-0000-20310 0 $1,331.00 $1,331.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for MULTI -SPECIES RESIDENTIAL: $1,331.00 $1,331.00 NEW CONSTRUCTION PERMIT 101-0000-42400 0 $600.89 $600.89 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for NEW CONSTRUCTION PERMIT: $600.89 $600.89 NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,223.64 $1,223.64 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,223.64 $1,223.64 PLAN CHECK DEPOSIT RESIDENTIAL 101-0000-42600 1 $750.00 $750.00 11/6/18 R40960 4338 CHECK J. FREDERICK WILSON AMA Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00 $750.00 BACKFLOW DEVICE 101-0000-42401 0 $13.34 $13.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 $5.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW BUILDING SEWER 101-0000-42401 0 $26.68 $26.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW BUILDING SEWER PC 101-0000-42600 0 $18.68 $18.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW FIXTURE/TRAP 101-0000-42401 0 $213.44 $213.44 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW FIXTURE/TRAP PC 101-0000-42600 0 $213.44 $213.44 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Printed: Thursday, July 27, 2023 5:05:55 PM 6 of 23 CRI f'SYSTEMS Permit Details PERMIT NUMBER City of La Quinta BRES2018-0353 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ PAID BY CLTD BY GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 $40.02 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 $26.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW WATER HEATER/VENT 101-0000-42401 0 $26.68 $26.68 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW WATER HEATER/VENT PC 101-0000-42600 0 $16.00 $16.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.34 $13.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.34 $13.34 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for PLUMBING FEES: $626.98 $626.98 RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 $21.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00 SMI - RESIDENTIAL 101-0000-20308 0 $19.95 $19.95 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for STRONG MOTION INSTRUMENTATION SMI: $19.95 $19.95 TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 $5.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 101-0000-42600 ($750.00) ($750.00) 5/16/19 OFFSET OFFSET JFU SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $750.00 $750.00 5/16/19 DEPOSIT DEPOSIT JFU Printed: Thursday, July 27, 2023 5:05:55 PM 7 of 23 CRWSYSTE S Permit Details PERMIT NUMBER City of La Quinta BRES2018-0353 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $1,560.00 $1,560.00 6/30/20 R61474 10394 CHECK TERRACE EAST APARTMENTS SSW Total Paid for TUMF - RESIDENTIAL: $1,560.00 $1,560.00 TOTALS: $14,646.90 $14,646.90 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES UNDERGROUND PLBG AOR 9/1/2020 9/1/2020 APPROVED eTRAKiT Inspection Request 8/31/2020 1:10 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM TEMPLATE FOOTING JAN 9/16/2020 9/16/2020 APPROVED eTRAKiT Inspection Request 9/15/2020 11:53 AM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM CALL FOR DRY -PACK INSPECTION WHEN READY. Printed: Thursday, July 27, 2023 5:05:55 PM 8 of 23 CRWSYSTE S Permit Details City of La Quinta SLAB JAN 9/16/2020 9/16/2020 DISAPPROVE D eTRAKiT Inspection Request 9/15/2020 11:53 AM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM REFERENCE TO FOOTING NOTES FOOTINGS JAN 9/16/2020 9/16/2020 DISAPPROVE D eTRAKiT Inspection Request 9/15/2020 11:53 AM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM -OBTAIN DRY -PACK INSPECTION APPROVAL PRIOR TO FOOTING INSPECTION PER DETAIL SD1/16 SLAB DCL 9/21/2020 9/21/2020 CANCELED eTRAKiT Inspection Request 9/18/2020 3:29 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM - CANCELLED PER CONTRACTOR REQUEST. Printed: Thursday, July 27, 2023 5:05:55 PM 9 of 23 CRWSYSTE S Permit Details City of La Quinta FOOTINGS DCL 9/21/2020 9/21/2020 CANCELED eTRAKiT Inspection Request 9/18/2020 3:29 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM - CANCELLED PER CONTRACTOR REQUEST. DRYPACK DCL 9/21/2020 9/21/2020 CANCELED eTRAKiT Inspection Request 9/18/2020 3:29 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM - CANCELLED PER CONTRACTOR REQUEST. SLAB DCL 9/22/2020 9/22/2020 DISAPPROVE D eTRAKiT Inspection Request 9/21/2020 1:23 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM - SEE FOOTING INSPECTION CORRECTIONS. DRYPACK DCL 9/22/2020 9/22/2020 APPROVED eTRAKiT Inspection Request 9/21/2020 1:23 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM Printed: Thursday, July 27, 2023 5:05:55 PM 10 of 23 CRWSYSTE S Permit Details City of La Quinta DRYPACK DCL 9/22/2020 9/22/2020 APPROVED eTRAKiT Inspection Request - SEE SPECIAL INSPECTION REPORT FOR DRY PACK IN ATTACHMENTS. FOOTINGS DCL 9/22/2020 9/22/2020 DISAPPROVE D eTRAKiT Inspection Request 9/21/2020 1:23 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM - PROVIDE THREE INCH MINIMUM CLEARANCE FROM REINFORCEMENT TO ADJACENT EARTH. SEE CASITA AND GARAGE GRADE BEAMS.AND FOOTING TRENCHES THROUGHOUT.- PROVIDE TWO REINFORCEMENT BARS IN RAISED CURB SECTION AT GARAGE PER 3, SD-1.- SIX FOOT , NUMBER FOUR SHEAR WALL AT EAST CORNER OF GARAGE MISSING.- PROVIDE CBSQ AT RIGHT SIDE OF ENTRY DOOR PER 12, SD-1.- PROVIDE UFER GROUND.- DEBRIS CONTAINER REQUIRED ON SITE. - FURTHER INSPECTION DISAPPROVALS WILL RESULT IN REINSPECTION FEES ASSESSED. - DEBRIS CONTAINER REQUIRED.- PROVIDE UFER GROUND.- THREE INCH MINIMUM CLEARANCE REQUIRED FROM REINFORCEMENT TO ADJACENT EARTH. SEE GRADE BEAMS AND FOOTINGS THROUGHOUT.- CBSQ MISSING AT RIGHT SIDE OF FRONT ENTRY.- NUMBER FOUR SHEAR WALL MISSING AT EAST CORNER OF GARAGE SEPARATION.- SIMPSON HARDWARE CALLED OUT. PROVIDE SIMPSON HARDWARE OR FOR APPROVAL FOR ALTERNATE. Printed: Thursday, July 27, 2023 5:05:55 PM 11 of 23 CRWSYSTE S Permit Details City of La Quinta FOOTINGS DCL 9/23/2020 9/23/2020 APPROVED eTRAKiT Inspection Request 9/22/2020 2:00 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM SLAB DCL 9/23/2020 9/23/2020 APPROVED eTRAKiT Inspection Request 9/22/2020 1:59 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM TEMPORARY POWER KKI 9/24/2020 9/24/2020 APPROVED eTRAKiT Inspection Request 9/23/2020 1:30 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM ROOF NAIL JAN 10/8/2020 10/8/2020 APPROVED SEWER CONNECTION KKI 12/11/2020 12/11/2020 APPROVED eTRAKiT Inspection Request 12/10/2020 2:10 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM Printed: Thursday, July 27, 2023 5:05:55 PM 12 of 23 CRWSYSTE S Permit Details City of La Quinta OKAY TO WRAP JAN 1/12/2021 1/12/2021 APPROVED eTRAKiT Inspection Request 1/11/2021 1:54 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM OVERHEAD ROUGH PIPING KHET 1/28/2021 1/28/2021 APPROVED ROUGH PLBG JAN 2/9/2021 2/9/2021 APPROVED eTRAKiT Inspection Request 2/8/2021 2:20 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM ROUGH MECH JAN 2/9/2021 2/9/2021 APPROVED eTRAKiT Inspection Request 2/8/2021 2:20 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM ROUGH ELEC JAN 2/9/2021 2/9/2021 APPROVED eTRAKiT Inspection Request 2/8/2021 2:19 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM Printed: Thursday, July 27, 2023 5:05:55 PM 13 of 23 CRWSYSTE S Permit Details City of La Quinta ROOF DRAIN JAN 2/9/2021 2/9/2021 NOT READY eTRAKiT Inspection Request 2/8/2021 2:19 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM -NOT ON TEST FRAMING JAN 2/9/2021 2/9/2021 APPROVED eTRAKiT Inspection Request 2/8/2021 2:19 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM ROOF DRAIN JAN 2/10/2021 2/10/2021 APPROVED eTRAKiT Inspection Request 2/9/2021 1:15 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM INSULATION KKI 2/25/2021 2/25/2021 APPROVED eTRAKiT Inspection Request 2/24/2021 2:26 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM LATH KKI 3/8/2021 3/8/2021 APPROVED DRYWALL NAIL KKI 3/8/2021 3/8/2021 APPROVED Printed: Thursday, July 27, 2023 5:05:55 PM 14 of 23 CRWSYSTE S Permit Details City of La Quinta SHOWER PAN KKI 3/31/2021 3/31/2021 APPROVED eTRAKiT Inspection Request 3/30/2021 3:11 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM TEMP USE OF PERM PWR KKI 5/18/2021 5/18/2021 NOT READY eTRAKiT Inspection Request 5/17/2021 1:01 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM TEMP USE OF PERM PWR AOR 5/19/2021 5/19/2021 NOT READY eTRAKiT Inspection Request 5/18/2021 2:26 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM MAIN SERVICE AND SUB -PANELS NOT OPEN FOR INSPECTION. TEMP USE OF PERM PWR JAN 5/20/2021 5/20/2021 APPROVED eTRAKiT Inspection Request 5/19/2021 1:45 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM FINAL INSPECTION KHET 10/18/2021 10/18/2021 APPROVED Printed: Thursday, July 27, 2023 5:05:55 PM 15 of 23 CRWSYSTE S Permit Details City of La Quinta PERMIT NUMBER BRE52018-035 111 GAS LINE/TEST JAN 2/10/2022 2/10/2022 DISAPPROVE D eTRAKiT Inspection Request 2/9/2022 1:11 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM -NO ACCESS PROVIDED,GATES LOCKED GAS LINE/TEST JAN 2/11/2022 2/11/2022 APPROVED FINAL** JAN 3/22/2022 3/22/2022 DISAPPROVE D eTRAKiT Inspection Request 3/21/2022 1:05 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM -PROVIDE VACANCY SENSOR AT BATHROOMS AND LAUNDRY ROOM - INSTALL GAS SHUT OFF AT LAUNDRY ROOM - COMPLETE LABELING OF SUB PANEL -AT CASITA PROVIDE AFC! FOR LIGHTS AND PLUGS -MECHANICAL ROOM LOCATED ON THE EAST EXTERIOR WALL LOCKED NO ACCESS PROVIDE -PROVIDE ACCESS TO MAIN SERVICE PANEL UNABLE TO OPEN AT TIME OF INSPECTION -PROVIDE HERS CERTIFICATION Printed: Thursday, July 27, 2023 5:05:55 PM 16 of 23 CRWSYSTE S Permit Details City of La Quinta PERMIT NUMBER BRE52018-035 111 FINAL** JAN 3/30/2022 3/30/2022 DISAPPROVE D eTRAKiT Inspection Request 3/29/2022 2:49 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM Inspector MHU changed the inspection assignment from MHU to JAN -MOTORIZED ROLLER SHADES WIRING CONNECTION SHALL COMPLY WITH THE REQUIREMENTS OF CEC 314- OBTAINED HERS CERTIFICATION FOR CASITA FINAL** JAN 4/4/2022 4/4/2022 DISAPPROVE D eTRAKiT Inspection Request 4/1/2022 2:11 PM CORONEL ENTERPRISES INC Contact Name: CORONEL ENTERPRISES INC Site Address: 77285 CALLE CHIHUAHUA Phone: 7607751234 e-Mail: ISH@CORONELENT.COM -JUNCTION BOXES INSTALLED ARE NOT LISTED FOR SURFACE MOUNT INSTALLATION, -PROVIDE LISTED CABLE CONNECTORS AT EACH KNOCKOUTS A RE INSPECTION FEE HAS BEEN ASSESSED. SEE ATTACHMENTS FOR REFERENCE FINAL** MHU 4/8/2022 4/8/2022 DISAPPROVE FEES ARE DUE FINAL** JFU 4/11/2022 4/11/2022 APPROVED PREVIOUS COMMENT RESOLVED OUTSTANDING FEES HAVE BEEN PAID. PARENT PROJECTS REVIEWS Printed: Thursday, July 27, 2023 5:05:55 PM 17 of 23 CRWSYSTE S _ Permit Details PERMIT NUMBER 1111111111 City of La Quints BRES2018-0353 REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED DATE STATUS REMARKS NOTES 1ST PERMIT TECH (1 DAY) ARMANDO MAGALLON 11/6/2018 11/7/2018 11/7/2018 COMPLETE 1ST PLANNING (2 WK) CHERI FLORES 11/6/2018 11/20/2018 11/19/2018 REVISIONS REQUIRED 1 SET FOR PLANNING AND FIRE PLEASE SUBMIT A SITE PLAN SHOWING SETBACKS.INCLUDE THE CALCULATION OF LANDSCAPE AREA. IF MORE THAN 2,500 SF, PLEASE SUBMIT LANDSCAPE PLANS TO CVWD FOR REVIEW AND APPROVAL.SUBMIT CVWD APPROVED AND SIGNED LANDSCAPE PLANS TO PLANNING PRIOR TO FINAL BUILDING PERMIT ISSUANCE. 1ST FIRE (2 WK) EDGAR GONZALEZ 11/6/2018 11/20/2018 11/21/2018 READY FOR APPROVAL 1 SET FOR PLANNING AND FIRE 1ST BLDG NS (2 WK) AJ ORTEGA 11/7/2018 11/26/2018 12/3/2018 REVISIONS REQUIRED SEE REVIEW EDITS ON COMPLETE HR GREEN REVIEW - THIS PERMIT ALSO REQUIRES PARCEL MERGER APPROVAL AND RECORDING PRIOR TO PERMIT ISSUANCE, SEE ATTACHED 1ST REVIEW CORRETION LIST. 1ST BLDG COMPLETE (2 WK) HR GREEN 11/7/2018 11/20/2018 11/19/2018 REVISIONS REQUIRED HR GREEN WILL CONDUCT A FULL REVIEW Comment letter in Attachments. Paul Armstrong COMMENTS REVIEWED IN HOUSE, INFORMATION EITHER FOUND ON PLANS OR DIRECTLY RESOLVED WITH APPLICANT, SEE 1ST REVIEW CORRECTION LIST FOR OFFICIAL/FINAL COMMENTS. 2ND PLANNING (1 WK) CHERI FLORES 5/8/2019 5/15/2019 5/14/2019 READY FOR APPROVAL 2ND BLDG NS (1 WK) JAKE FUSON 5/8/2019 5/15/2019 5/16/2019 REVISIONS REQUIRED CORRECTIONS REMAIN FROM FIRST PLAN REVIEW, SEE 2ND REVIEW CORRECTION LIST. 1ST PW GREEN SHEET AMY YU 8/1/2019 8/8/2019 8/8/2019 READY FOR APPROVAL FOR PM-10 ONLY Printed: Thursday, July 27, 2023 5:05:55 PM 18 of 23 CRWSYSTE S Permit Details City of La Quinta 3RD BLDG NS (1 WK) JAKE FUSON 8/1/2019 8/8/2019 8/21/2019 REVISIONS REQUIRED PRECISE GRADING PLAN PRECISE GRADING PLAN SUBMITTED BY ISH CORONEL AND IS WITH FILE FOLDER. -PROVIDE NOTE ON PLANS FROM ENGINEER STATING "THIS PLAN HAS BEEN PREPARED SO THAT EARTH FILL WILL NOT EXCEED WHAT IS NECESSARY TO PROVIDE MINIMUM REQUIRED DRAINAGE TO THE STREET." -PROVIDE 2" CLEARANCE FROM FINISH FLOOR TO FLAT WORK AT FRONT ENTRY DOOR AREA TO ALLOW FOR WEEP SCREED INSTALLATION -PROVIDE THE ENTIRE REVISED PLAN SET AND ALL OTHER DOCUMENTS UPON RESUBMITTAL 4TH BLDG NS (1 WK) JAKE FUSON 2/3/2020 2/10/2020 3/3/2020 REVISIONS REQUIRED -RESOLVE 3RD REVIEW CORRECTIONS GIVEN REGARDING PRECISE GRADING PLAN INCORPORATE THE REVISED PRECISE GRADING PLANS INTO THE PLAN SETS PRIOR TO RESUBMITTING -PROVIDE FOR APPROVAL OF TRUSS DESIGNS 5TH BLDG NS (1 WK) JAKE FUSON 6/10/2020 6/17/2020 6/11/2020 APPROVED 1ST PERMIT TECH — ETRAKIT (1 DAY) AJ ORTEGA 9/30/2020 10/1/2020 10/1/2020 INCOMPLETE REVISION 1: ENERGY COMPLIANCE DETERMINED INCOMPLETE, NO PLANS WERE UPLOADED WITH ENERGY COMPLIANCE REPORT, AND IT IS UNREGISTERED, EMAIL SENT TO CONTRACTOR AND APPLICANT. 1ST BLDG NS ETRAKIT (1 WK) JAKE FUSON 12/1/2020 12/8/2020 12/9/2020 REVISIONS REQUIRED REVISION 2 REVISION 2 - ADD MECHANICAL CLOSET AND RELOCATE HVAC UNITS. IT APPEARS THAT REVISION 1 AND REVISION 2 WERE COMBINED INTO ONE NEW REVISED PLAN SET & ENERGY REPORT, HOWEVER FENESTRATION VALUES DO NOT MATCH. EMAIL SENT TO ISH CORONEL. 2ND BLDG NS — ETRAKIT (1 WK) JAKE FUSON 12/15/2020 12/22/2020 12/17/2020 APPROVED REVISION 2 REVISION 2 UPDATED FENESTRATION VALUES, ADDED HVAC SYSTEM AND NEW HVAC CLOSET. BOND INFORMATION Printed: Thursday, July 27, 2023 5:05:55 PM 19 of 23 CRWSYSTE S Permit Details Ai City of La Quinta PERMIT NUMBER BRES2018-0353 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/3/2018 AJ ORTEGA 1ST REVIEW COMPLETE CORRECTIONS BRE52018 0353 1ST REVIEW COMPLETE CORRECTIONS.pdf 1 DOC 12/3/2018 AJ ORTEGA SCHOOL FEE CERTIFICATION OF BUILDING AREA BRES2018-0353 - SCHOOL FEE CERTIFICATION OF BUILDING AREA.pdf 1 DOC 8/8/2019 AMY YU GREEN SHEET BRES2018 0353 GREEN SHEET.pdf 0 DOC 1/6/2020 AMY YU RECORDED PARCEL MERGER 2019-0001 RECORDED PARCEL MERGER 2019-0001.pdf 0 DOC 6/10/2020 EtrakitContractor 5TH SUBMITTAL TRUSS CALCULATIONS BRES2018 0353 4TH SUBMITTAL TRUSS CALCULATIONS.pdf 1 DOC 6/10/2020 EtrakitContractor 5TH SUBMITTAL ENERGY DOCUMENTS (CASITA) BRES2018-0353 - 5TH SUBMITTAL ENERGY DOCUMENTS (CASITA).pdf 1 DOC 6/10/2020 EtrakitContractor 5TH SUBMITTAL ENERGY DOCUMENTS (MAIN DWELLING) BRES2018-0353 - 5TH SUBMITTAL ENERGY DOCUMENTS (MAIN DWELLING).pdf 1 DOC 6/10/2020 EtrakitContractor 5TH SUBMITTAL STRUCTURAL CALCULATIONS BRES2018-0353 - 5TH SUBMITTAL STRUCTURAL CALCULATIONS.pdf 1 DOC 6/10/2020 EtrakitContractor 5TH SUBMITTAL PLAN SET BRES2018 0353 5TH SUBMITTAL PLAN SET.pdf 1 DOC 6/30/2020 EtrakitContractor WASTE MANAGEMENT PLAN CHIHUAHUA, DEBRI.pdf 1 Printed: Thursday, July 27, 2023 5:05:55 PM 20 of 23 CRWSYSTEMS Permit Details City of La Quinta In PERMIT NUMBER BRES2018-0353 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/30/2020 EtrakitContractor PROPERTY DETAILS CHIHUAHUA, DEED.pdf 1 DOC 6/30/2020 EtrakitContractor SCHOOL FEE RECEIPT (CERTIFICATE OF COMPLIANCE) CHIHUAHUA, SCHOOL.pdf 1 DOC 6/30/2020 EtrakitContractor GRANT DEED 20200630_151259.pdf 1 DOC 9/10/2020 EtrakitContractor PAD CERT 185549p.001 Pad and Form Certification.pdf 1 DOC 9/22/2020 EtrakitContractor Dry pack deputy inspector Scan2020 09 22_064227.pdf 1 DOC 9/30/2020 EtrakitContractor REVISION 1- ENERGY REPORT CHIHUAHUA, REVISED TITLE 24.pdf 1 DOC 12/3/2020 EtrakitContractor REVISION 2 1ST SUBMITTAL PLAN SET 77285 Calle Chihuahua Revised Title 24s.pdf 1 DOC 12/3/2020 EtrakitContractor Revised Title 24's Casa Chi Revised CD Set [2020.12.03].pdf 1 DOC 12/3/2020 EtrakitContractor REVISION 2 - 1ST SUBMITTAL STRUCTURAL CALCULATIONS Structural Calcs (rev2).pdf 1 DOC 12/14/2020 EtrakitContractor Revised Title 24's 77285 Calle Chihuahua Revised Title 24s_1.pdf 1 DOC 12/14/2020 EtrakitContractor REVISION 2 2ND SUBMITTAL PLAN SET Casa Chi Revised CD Set [2020.12.15].pdf 1 DOC 1/11/2021 EtrakitContractor STRUCTURAL WALK CHIHUAHUA WALK.pdf 1 DOC 1/24/2022 Etrakit Contractor HERS TESTING 77-285 Calle Chihuahua - All Documents (4).pdf 1 DOC 4/6/2022 Etrakit Contractor CASITA HERS TESTING 77-285 Calle Chihuahua - All Documents (8).pdf 1 Printed: Thursday, July 27, 2023 5:05:55 PM 21 of 23 CRWSYSTEMS Permit Details Ai City of La Quinta PERMIT NUMBER BRES2018-0353 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 11/19/2018 HR GREEN 1ST REVIEW HR GREEN (DO NOT DISTRIBUTE) BRES2018-0353 - BRES2018 0353 1ST REVIEW HR GREEN (DO NOT DISTRIBUTE).docx 0 DOC 5/16/2019 JAKE FUSON 2ND REVIEW CORRECTION LIST BRES2018-0353 - 2ND REVIEW CORRECTION LIST.pdf 1 DOC 6/11/2020 JAKE FUSON APPROVED ENERGY DOCUMENTS (CASITA) BRES2018-0353 - APPROVED ENERGY DOCUMENTS (CASITA).pdf 1 DOC 6/11/2020 JAKE FUSON APPROVED ENERGY DOCUMENTS (MAIN DWELLING) BRES2018 0353- APPROVED ENERGY DOCUMENTS (MAIN DWELLING).pdf 1 DOC 6/11/2020 JAKE FUSON APPROVED PLAN SET BRES2018-0353 - APPROVED PLAN SET.pdf 1 DOC 6/11/2020 JAKE FUSON APPROVED STRUCTURAL CALCULATIONS BRES2018-0353 - APPROVED STRUCTURAL CALCULATIONS.pdf 1 DOC 6/11/2020 JAKE FUSON APPROVED TRUSS CALCULATIONS BRES2018 0353- APPROVED TRUSS CALCULATIONS.pdf 1 DOC 12/17/2020 JAKE FUSON REVISION 2 - APPROVED ENERGY REPORT BRES2018 0353- REVISION 2 - APPROVED ENERGY REPORT.pdf 1 DOC 12/17/2020 JAKE FUSON REVISION 2 - APPROVED PLAN SET BRES2018 0353- REVISION 2 - APPROVED PLAN SET.pdf 1 Printed: Thursday, July 27, 2023 5:05:55 PM 22 of 23 CRWSYSTEMS Permit Details City of La Quinta PERMIT NUMBER BRE52018-0351d1 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 12/17/2020 JAKE FUSON REVISION 2 - APPROVED STRUCTURAL CALCULATIONS BRES2018 0353 - REVISION 2 APPROVED STRUCTURAL CALCULATIONS.pdf 1 Printed: Thursday, July 27, 2023 5:05:55 PM 23 of 23 CRWSYSTE S 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type/Subtype: Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: GABRIEL RIOS 49901 CINNABAR LN COACHELLA, CA 92236 c6iiiti 4Otibtlai DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT BUILDING RESIDENTIAL (WEB)/DWELLING - SINGLE FAMILY DETACHED BRES2018-0353 77285 CALLE CHIHUAHUA 774041001 CASA CHI LLC/2,440SF SFD W/ CASITA / VB/RES-3/CLASS A-FR/13D $153,450.10 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: WILSON JACK M & MAJEL A 77285 CALLE CHIHUAHUA LA QUINTA, CA 92253 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 Llc. No.: 727199 Date: 3/6/2023 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000} of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 727199 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: () I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: BENCHMARK INSURANCE COMPANY Policy Number: CST5018011 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above -mentioned property for inspection purposes. Date: Signature (Applicant or Agent): Date: 3/6/2023 Application Number: Property Address: APN: Application Description: Property Zoning: Application Valuation: Applicant: GABRIEL RIOS 49901 CINNABAR LN COACHELLA, CA 92236 BRES2018-0353 77285 CALLE CHIHUAHUA 774041001 CASA CHI LLC/2,440SF SFD W/ CASITA / VB/RES-3/CLASS A-FR/13D $153,450.10 Owner: WILSON JACK M & MAJEL A 77285 CALLE CHIHUAHUA LA QUINTA, CA 92253 Contractor: CORONEL ENTERPRISES INC 42760 MADIO STREET INDIO, CA 92201 (760)775-1234 Llc. No.: 727199 Detail: CASA CHI LLC / 2,440SF DWELLING W/ CASITA (MAIN HOUSE 2,112SF + CASITA 328SF) [VB/RES-3/CLASS A-FR/13D] THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES. FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT RE -INSPECTION FEE 101-0000-42400 0 $83.37 Total Paid for ADMINISTRATIVE: $83.37 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.75 $120.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 1 $161.00 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 0.5 $80.50 DESCRIPTION ACCOUNT QTY AMOUNT HOURLY CHARGE - CITY BUILDING STAFF 101-0000-42600 1.5 $241.50 Total Paid for BLDG CITY STAFF - PER HOUR: $603.00 DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $7.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $7.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - CIVIC CENTER 252-0000-43200 0 $942.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - LIBRARIES 253-0000-43200 0 $344.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - PARKS/REC 251-0000-43200 0 $2,048.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 DESCRIPTION ACCOUNT QTY AMOUNT DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE 101-0000-42403 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT TEMP POWER SERVICE PC 101-0000-42600 0 $18.68 Total Paid for ELECTRICAL: $45.36 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF 101-0000-42403 0 $27.22 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, EA ADDITION 1,000SF, PC 101-0000-42600 0 $11.20 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $160.10 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $52.83 Total Paid for ELECTRICAL - NEW CONSTRUCTION: $251.35 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF 101-0000-42408 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT RESIDENTIAL PRECISE GRADING - CUSTOM HOME LOT >7KSF PC 101-0000-42600 0 $200.12 Total Paid for GRADING: $240.14 DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT AIR HANDLER PC 101-0000-42600 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $80.04 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $53.36 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD 101-0000-42402 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT EXHAUST HOOD PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE 101-0000-42402 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT FURNACE PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN 101-0000-42402 0 $80.04 DESCRIPTION ACCOUNT QTY AMOUNT VENT FAN PC 101-0000-42600 0 $32.04 Total Paid for MECHANICAL: $384.22 DESCRIPTION ACCOUNT QTY AMOUNT MULTI -SPECIES RESIDENTIAL 0-8 UNITS - 2019 UPDATE 101-0000-20310 0 $1,331.00 Total Paid for MULTI -SPECIES RESIDENTIAL: $1,331.00 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PERMIT 101-0000-42400 0 $600.89 Total Paid for NEW CONSTRUCTION PERMIT: $600.89 DESCRIPTION ACCOUNT QTY AMOUNT NEW CONSTRUCTION PLAN CHECK 101-0000-42600 0 $1,223.64 Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,223.64 DESCRIPTION ACCOUNT QTY AMOUNT PLAN CHECK DEPOSIT - RESIDENTIAL I 101 0000 42600 I 1 I $750.00 Total Paid for PLAN CHECK DEPOSIT - RESIDENTIAL: $750.00 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT BACKFLOW DEVICE PC 101-0000-42600 0 $5.34 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT BUILDING SEWER PC 101-0000-42600 0 $18.68 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP 101-0000-42401 0 $213.44 DESCRIPTION ACCOUNT QTY AMOUNT FIXTURE/TRAP PC 101-0000-42600 0 $213.44 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS 101-0000-42401 0 $40.02 DESCRIPTION ACCOUNT QTY AMOUNT GAS SYSTEM, 5+ OUTLETS PC 101-0000-42600 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $26.68 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $16.00 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $13.34 DESCRIPTION ACCOUNT QTY AMOUNT WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $13.34 Total Paid for PLUMBING FEES: $626.98 DESCRIPTION ACCOUNT QTY AMOUNT RECORDS MANAGEMENT FEE - MAJOR 101-0000-42416 0 $21.00 Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $19.95 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $19.95 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 DESCRIPTION ACCOUNT QTY AMOUNT 101-0000-42600 ($750.00) DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 0 $750.00 DESCRIPTION ACCOUNT QTY AMOUNT SINGLE FAMILY DETACHED 2018 UPDATE 224-0000-20320 I 0 I Total Paid for TUMF - RESIDENTIAL: $1,560.00 $1,560.00 TOTALS: $14,646.90 1 Certificate of Occupancy Design and Development Department GEM of the DESERT This Certificate is issued pursuant to the requirements of Chapter 1 Section R110 of the California Residential Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 77285 CALLE CHIHUAHUA Use classification: RESIDENTIAL - SINGLE FAMILY DWELLING Permit No.: BRES2018-0353 Occupancy Group: R-3/U Type of Construction: VB Land Use Zone: RVL Code Edition: 2016 Sprinkler Installed: NO Sprinkler Required: NO By: JAKE FUSON Owner of Building: MARY PETERSON Date: 4/11/2022 Address: 77285 CALLE CHIHUAHUA Building Official: A) ORTEGA City, ST, ZIP: LA QUINTA, CA 92253 POST IN A CONSPICUOUS PLACE CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:20, Wed, Apr 06, 2022 Calculation Description: Title 24 Analysis Input File Name: Pepe Builds 77285 Calle Chihuahua Casita.ribdl6x CF1 R-PRF-01 Page 1 of 6 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 Project Location 77-285 Calle Chihuahua 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 328 15 Number of Zones 1 16 Slab Area (ft2) 328 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 31.7% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 1.08 3.38 -2.30 -213.0% Space Cooling 233.38 231.52 1.86 0.8% IAQ Ventilation 4.67 4.67 0.00 0.0% Water Heating 35.00 29.08 5.92 16.9% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 274.13 268.65 5.48 2.0% Registration Number: 422-P010049211A-000-000-0000000-0000 Registration Date/Time: 04/06/2022 13:17 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2022-04-06 13:21:16 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:20, Wed, Apr 06, 2022 Calculation Description: Title 24 Analysis Input File Name: Pepe Builds 77285 Calle Chihuahua Casita.ribdl6x CF1 R-PRF-01 Page 2 of 6 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 65.4 64.6 0.0 64.6 • Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ■ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. • Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins • Central parallel piping HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • -- None -- HVAC Distribution System Verifications: • -- None -- Domestic Hot Water System Verifications: • -- None -- BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 328 1 3 1 0 1 Registration Number: 422-P010049211 A-000-000-0000000-0000 Registration Date/Time: 04/06/2022 13:17 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2022-04-06 13:21:16 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:20, Wed, Apr 06, 2022 Calculation Description: Title 24 Analysis Input File Name: Pepe Builds 77285 Calle Chihuahua Casita.ribdl6x CF1 R-PRF-01 Page 3 of 6 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Casita Conditioned Casital 328 9 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Front Wall Casita R-21 Wall 0 Front 320 79.996 90 Left Wall Casita R-21 Wall 90 Left 250 6 90 Rear Wall Casita R-21 Wall 180 Back 320 0 90 Right Wall Casita R-21 Wall 270 Right 250 18 90 Roof Casita R-38 Roof Attic n/a n/a 328 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Casita Attic RoofCasita Ventilated 0 0.7 0.75 Yes Yes FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Window Window Front Wall (Front-0) 8.0 8.0 1 64.0 0.40 0.30 Insect Screen (default) Window 2 Window Front Wall (Front-0) 8.0 1.5 0.833 10.0 0.40 0.30 Insect Screen (default) Window 3 Window Front Wall (Front-0) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 4 Window Left Wall (Left-90) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 5 Window Right Wall (Right-270) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 6 Window Right Wall (Right-270) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 7 Window Right Wall (Right-270) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Registration Number: 422-P010049211A-000-000-0000000-0000 Registration Date/Time: 04/06/2022 13:17 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2022-04-06 13:21:16 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:20, Wed, Apr 06, 2022 Calculation Description: Title 24 Analysis Input File Name: Pepe Builds 77285 Calle Chihuahua Casita.ribdl6x CF1 R-PRF-01 Page 4 of 6 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 2 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 3 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 4 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 5 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Attic RoofCasita Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. none 0.644 • Cavity/Frame: no insul. /2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking • Roofing: Light Roof (Asphalt Shingle) R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: 3 Coat Stucco R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 • Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 • Over Ceiling Joists: R-28.9 insul. SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Casita 328 85 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a Registration Number: 422-P010049211 A-000-000-0000000-0000 Registration Date/Time: 04/06/2022 13:17 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2022-04-06 13:21:16 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:20, Wed, Apr 06, 2022 Calculation Description: Title 24 Analysis Input File Name: Pepe Builds 77285 Calle Chihuahua Casita.ribdl6x CF1 R-PRF-01 Page 5 of 6 WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (1) 1 .0% WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Instantaneous 1 0.100000 0.99 EF <= 200 kBtu/hr R-0/R-0 0 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Casita1 Heat Pump Heating and Cooling System Heat Pump System 1 Heat Pump System 1 None - none - HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 DuctlessMiniSplitHeatPump 1 6 25000 17500 14 12.2 Not Zonal Single Speed Heat Pump System 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Heat Pump System 1-hers-cool Not Required n/a Not Required Not Required Not Required IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 33 0.25 Default 0 Required Registration Number: 422-P010049211 A-000-000-0000000-0000 Registration Date/Time: 04/06/2022 13:17 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2022-04-06 13:21:16 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Date/Time: 13:20, Wed, Apr 06, 2022 Calculation Description: Title 24 Analysis Input File Name: Pepe Builds 77285 Calle Chihuahua Casita.ribdl6x CF1 R-PRF-01 Page 6 of 6 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Joan Hacker Documentation Author Signature: JoYAAyV 1- CGOICRAE Company: Joan Hacker Signature Date: 04/06/2022 Address: 72875 Fred Waring Drive CEA/HERS Certification Identification (If applicable): City/State/Zip: Palm Desert, CA 92260 Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Joan Hacker Responsible Designer Signature: J019(/ cc,c,kor Company: Joan Hacker Date Signed: 04/06/2022 Address: 72875 Fred Waring Drive License: City/State/Zip: Palm Desert, CA 92260 Phone: 760-345-1352 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211 A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 04/06/2022 13:17 HERS Provider: CHEERS Report Version - CF1 R-01162019-1149 Report Generated at: 2022-04-06 13:21:16 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-SRA-01-E Solar Ready Buildings - New Construction (Page 1 of 2) Project Name: Pepe Builds - Casita Date Prepared: 2022-04-06 A. General Information Do not use this form to show solar ready compliance for hotel/motel occupancies and high-rise multifamily buildings with ten stories or fewer and all other nonresidential buildings with three stories or fewer. Instead, use form N RCC-SRA-01-E 01 Building Type Single family 02 Method of Compliance Residence not in an applicable subdivision B. Building Meets the Solar Ready Requirements This section does not apply to this project. C. Residence not in an Applicable Subdivision 01 The single family residence is located in a subdivision with fewer than ten single family residences, or where the application for a tentative subdivision map for the residences was deemed complete by the enforcement agency, before January 1, 2014. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. D. Permanently Installed Solar Photovoltaic (PV) System This section does not apply to this project. E. Permanently Installed Solar Water Heating System This section does not apply to this project. F. Smart Thermostats and Alternative Efficiency Measure This section does not apply to this project. G. Roof is Designed for Vehicle Traffic or Parking or for Heliport (Applies to Low-rise Multifamily only) This section does not apply to this project. Registration Number: 422-P010049211A-R01002A CA Building Energy Efficiency Standards 2016 Residential Compliance Registration Date/Time: 2022-04-06 13:40:55 HERS Provider: CHEERS Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:56 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-SRA-01-E Solar Ready Buildings - New Construction (Page 2 of 2) Documentation Author's Declaration Statement 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 'r Bat,( , Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: David Leal Responsible Designer Signature: 'vim Lec 2• Company : Compressor Air Conditioning and Heating Date Signed: 2022-04-06 Address: 47892 Pheonix Street License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-R01002A CA Building Energy Efficiency Standards 2016 Residential Compliance Registration Date/Time: 2022-04-06 13:40:55 HERS Provider: CHEERS Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:56 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 1 of 3) Project Name: Pepe Builds - Casita Enforcement Agency: La Quinta, City of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. The signer agrees that all applicable Mandatory Measures were met. Temporary labels are not to be removed before verification by the building inspector. A. Fenestration Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) and SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacture r/Brand Fenestration z Area (ft) Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/S pecial Features Window OWENS 64.0000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 2 OWENS 10.0000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 3 OWENS 6.0000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 4 OWENS 6.0000 90 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 5 OWENS 6.0000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Registration Number: 422-P010049211A-000-001-E01017A-0000 Registration Date/Time: 2022-04-06 13:40:01 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:33 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 2 of 3) A. Fenestration Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) and SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacture r/Brand Fenestration Area (ft2) Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/S pecial Features Window 6 OWENS 6.0000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 7 OWENS 6.0000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens B. Fenestration Installation 01 For new construction, installed window U-factor and SHGC values should be equal to or less than listed on the CF1R. 02 For existing buildings the U-factor and SHGC values should be the same or better than the required Energy Commission prescriptive requirements. 03 Temporary labels should not be removed until verified by the building inspector. 04 The fenestration product manufacturer's installation specifications shall be followed when installing these products. The space between the fenestration product and rough opening shall be completely filled with insulation. If batt insulation is used, it is cut to size and placed properly around the fenestration product. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-E01017A-0000 Registration Date/Time: 2022-04-06 13:40:01 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:33 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-VV►i 13a.drld w Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douv1.th (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E01017A-0000 Registration Date/Time: 2022-04-06 13:40:01 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:33 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 1 of 8) Project Name: Pepe Builds - Casita Enforcement Agency: La Quinta, City of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Medium and light density SPF manufacturers claim various R-values per inch. In California the maximum R-value that can be claimed for ccSPF is an R-value of 5.8 per inch and for ocSPF is an R-value of 3.6 per inch unless documentation is provided showing that the product and/or manufacturer has a current ICC Evaluation Service Report (ESR) that shows compliance with Acceptance Criteria for Spray -Applied Foam Plastic Insulation-AC377. Note: The Energy Standards Section 110.7 requires that 'all joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weather stripped, or otherwise sealed to limit infiltration and exfiltration.' In areas where spray foam (SPF) insulation is used, the SPF can be considered the air barrier. Other than rigid board insulation, all other forms of insulation are not considered as an air barrier. A. Roof/Ceiling Insulation 01 02 03 04 05 06 07 08 09 10 I.D. Manufacturer and Brand Assembly/Frami ng Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value Roof OWENS Wood Framed Ceiling 15.12 2x4 @ 24 in. O.C. Expanded polystyrene This field or section is not applicable 38 5.5 21 Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 2 of 8) B. Wall Insulation 01 02 03 04 05 06 07 08 09 10 I.D. Manufacturer and Brand Assembly/Frami ng Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value Front Wall OWENS Wood Framed Wall 6.88 2x6 @ 16 in. O.C. Fiberglass This field or section is not applicable 21 5.5 21 Left Wall OWENS Wood Framed Wall 6.88 2x6 @ 16 in. O.C. C Fiberglass This field or section is not applicable 21 5.5 21 Rear Wall Wood Framed Wall 6.88 2x6 @ 16 in. C O.C. Fiberglass This field or section is not applicable 21 This field or section is not applicable This field or section is not applicable Right Wall Wood Framed Wall 6.88 2x6 @ 16 in. O.C. C Fiberglass This field or section is not applicable 21 This field or section is not applicable This field or section is not applicable C. Mass Insulation This section does not apply to this project. D. Raised Floor Insulation This section does not apply to this project. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 3 of 8) E. Slab Floor/Perimeter Insulation (See Section F. For Insulation Requirements For Heated Slabs) This section does not apply to this project. F. Heated Slabs Insulation 01 All heated slabs shall be insulated as required by Section 110.8(g). Footings must meet required insulation levels. 02 Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-15 require R-5, and climate zone 16 requires R-10. 03 Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires R-10 vertical and R-7 horizontal. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Minimum Mandatory Measures 01 Insulation - 110.8(a): All installed Insulation is certified and listed with Department of Consumer Affairs, "Standards for Insulating Material". 02 Insulation - 110.8(b): Urea formaldehyde foam insulation is protected by 4 mil polyethylene vapor retarder. 03 Insulation - 110.8(c): Flame spread and smoke density requirements of CBC are met. 04 Raised Floor - 150.0(d): All raised wood -frame floor have a minimum R-19 insulation or equivalent U-factor 05 Slab Floor/Perimeter - 150.0(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and is protected from physical damage and UV Tight deterioration. 06 Above Grade Exterior Wall - 150.0(c)1: All 2x4 wood -frame walls have a minimum R-13 insulation or equivalent U-factor. 07 Above Grade Exterior Wall - 150.0(c)2: All 2x6 wood -frame walls have a minimum R-19 insulation or equivalent U-factor. 08 Ceiling/Rafter Roof - 150.0(a)1: All wood -frame ceiling have a minimum R-22 insulation or equivalent U-factor. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 4 of 8) G. Minimum Mandatory Measures 09 Vapor Retarder - 150(g)1: In Climate Zones 1 through 16, the earth floor of unvented crawl space shall be covered with a Class I or Class II vapor retarder. This requirement shall also apply to controlled ventilation crawl space for buildings complying with the Exception to Section 150.0(d). 10 Vapor Retarder - 150(g)2: In Climate Zones 14 and 16, a Class I or Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. 11 Heated Slabs - 110.8(g): All heated slabs shall be insulated as required. • Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-5 require R-5, and climate zone 16 requires R-10. • Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires R-10 vertical and R-7 horizontal. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. H. Installed Insulation 01 Installed insulation R-values are the same or greater than listed on the CF1R. 02 No gaps or voids between the insulation and framing. 03 No gaps between the sides or ends of batt insulation. 04 Loose -fill insulation must be installed to the minimum installed weight per square foot (density) of the manufacturer's cut sheet for the proposed R-value. 05 Batt insulation is not compressed (no stuffing of the insulation into the cavity) and is installed to its full thickness. 06 Insulation is cut around obstructions such as electrical boxes. 07 Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors. 08 Band joists are insulated to the same R-value as the wall. 09 In all narrow cavities the insulation shall be cut to fit or filled with expanding foam. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 5 of 8) H. Installed Insulation 10 Insulation was installed per manufacturer instructions. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Wall Insulation 01 When allowed by manufacturer, low expanding foam shall be used to fill gaps and voids around windows and doors. If not, the cavity must be air tight and filled completely with insulation. Batt insulation must be cut to width. No stuffing allowed. 02 Install wall insulation before installing tubs, showers and fireplaces. 03 Electric panels on walls separating conditioned and unconditioned space are sealed and insulated behind the panel with rigid insulation or expanding foam. 04 All walls of interior closets vented to the outside for HVAC or water heating equipment have the same R-value and air barrier as the exterior walls and ceiling. Doors are insulated and weather stripped. 05 Ducting not allowed in exterior walls unless insulated to R6 or greater and the insulation and duct are not crushed. Ducting not allowed in 2x4 wall assemblies. 06 Corner channels, wall intersections, and double sided shear walls insulated to the required R-value before enclosing the wall. 07 Insulation that does not fill the cavity placed against exterior air barrier. 08 Band joists are insulated to the same R-value as the walls. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. J. Ceiling Roof Insulation 01 Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams/baffles. 02 Insulation is in direct contact with ceiling, so there are no gaps between the ceiling and the insulation. 03 For chimneys and flues, the insulation is in contact with the sheet metal collar. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 6 of 8) J. Ceiling Roof Insulation 04 Can lights are covered with insulation to the same depth as required by the CF1R for ceiling insulation. If not an area weighted calculation is required to be turned in with this compliance document. 05 Walkways and mechanical platforms insulated to the same R-value as required for the ceiling. If not an area weighted calculation is required to be turned in with this compliance document. 06 Insulate soffits by adding an air barrier and cover with insulation, or insulate the entire soffit including floor and walls. 07 Knee walls and skylight shafts are insulated to the wall R-value and in full contact with the interior air barrier. If framing on these surfaces is laid flat batt insulation is cut to fit around the framing. Batt insulation is not allowed to be draped over the framing. 08 Attic access doors insulated to the same R-value as ceiling. The insulation is permanently attached using adhesive or mechanical fasteners. 09 Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation. 10 Batt insulation cut to fit around cross bracings and truss webs in attic. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. K. Raised Floor Insulation 01 Insulation in full contact with subfloor. 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 04 If the basement is conditioned the walls adjacent to the crawlspace must meet minimum wall R-value requirements. This includes framed stem walls, and vertical concrete retaining walls. 05 If access to the crawl space is from the conditioned area, the raised floor must have an airtight insulated access hatch. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 7 of 8) L. Floor Above Garage Insulation 01 Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage/house wall. 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 04 If air barrier is at the perimeter of the garage, below conditioned subfloor, the insulation is placed on the garage ceiling. The perimeter of subfloor is also insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. M. Cantilevered Floor Insulation 01 Insulation in full contact with cantilevered subfloor. Insulation hangers spaced at 18 inches or less, insulation hangers do not compress insulation. 02 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 03 Sealed blocking is installed between joists where wall rim joist would be located in the absence of a cantilever. Insulation is placed on both sides of this block. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. N. Attached Porch Roof Insulation 01 The exterior insulated wall at the intersection with the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is at the top and bottom of each wall/roof section and insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 8 of 8) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-VV►i 13a.drld w Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douvilth (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E03015A-0000 Registration Date/Time: 2022-04-06 13:37:36 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:45:37 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 1 of 5) Project Name: Pepe Builds - Casita Enforcement Agency: La Quinta, City of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Radiant Barrier 01 Brand Name and product number 02 Installation Type Attached to underside of roof deck, with perforations to allow moisture/vapor transfer 03 Total Attic Area (ft2) 1000 B. Schedule of Lower Vents The Net Free Area (NFA) of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non -manufactured products, assume that the net free area is one third of the total aperture area. 01 02 03 04 Type of Vent For instance, eyebrow vent, eave vent, round vent NFA per vent (in2) (Manufacturers Specification Sheet) Number of Vents Installed Total NFA Per Vent Type (in2) Other 10 20 200 C. Schedule of Upper Vents The Net Free Area of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non -manufactured products, assume that the net free area is one third of the total aperture area. 01 02 03 04 Registration Number: 422-P010049211A-000-001-E04016A-0000 Registration Date/Time: 2022-04-06 13:39:28 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:47:29 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 2 of 5) C. Schedule of Upper Vents Type of Vent For instance, eyebrow vent, eave vent, round vent NFA per vent (in2)/Per Linear Foot (Manufacturer Specification Sheet) Total NFA Per Vent Type (in2) Other 5 100 500 D. Required Vent Area 01 Combined NFA of installed upper and lower vents (in2) 700 02 Minimum required combined NFA of upper and lower vents (in2) 480 03 NFA of installed upper vents (in2) 500 04 Minimum required NFA of upper vents (in2) 144 05 Compliance Statement Building complies E. Radiant Barrier and Attic Ventilation - Additional Requirements Radiant Barrier 01 Radiant barrier must be installed on all vertical surfaces in the attic including gable ends. 02 The emittance of the radiant barrier shall be less than or equal to 0.05 as tested with ASTM C1371, or E408. 03 The product shall meet all requirements for California certified insulation materials (radiant barriers) of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation, as specified by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material 04 When determining the Total Attic Area, the area over unconditioned spaces such as the garage is included when the attic spaces are connected Lower Vents Registration Number: 422-P010049211A-000-001-E04016A-0000 Registration Date/Time: 2022-04-06 13:39:28 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:47:29 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 3 of 5) E. Radiant Barrier and Attic Ventilation - Additional Requirements 05 Lower vents are within one foot of the eave. Upper Vents 06 Upper vents are within three feet of the ridge. Vent Area 07 The NFA of upper vents must be within required NFA range of upper vents Note: per Exception to R806.2 of the CBC Title 24, Part2, VoI.2.5, if the net free ventilating area is less than 1:150, then the upper ventilation must be at least 40% and no more than 50%. Part 2 contains additional requirements that must be met if the area is less than 1:150. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. F. Roofing Products (Cool Roof) Installation Information 01 02 03 04 05 06 07 08 09 10 11 12 Tag/ID Roof Pitch CRRC Product ID Number Product type CRRC Listed Aged Solar Reflectance Installed Required Initial Solar Reflectance Aged Solar Reflectance Thermal Emittance SRI Aged Solar Reflectance Thermal Emittance SRI 156167321 Roof pitch is greater than 2 :12 21578315 Clay roof tiles No 1 .79 .89 314654412 0.7 .79 126541564 G. Roofing Products (Cool Roof) - Additional Requirements 01 Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements 02 Liquid field applied coatings must comply with installation criteria from section 110.8(i)4 Registration Number: 422-P010049211A-000-001-E04016A-0000 Registration Date/Time: 2022-04-06 13:39:28 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:47:29 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 4 of 5) G. Roofing Products (Cool Roof) - Additional Requirements 03 Mass roof 25 Ib/ft2 or greater: Mass roofs are not required to have a cool roof even if the climate zone specifies minimum performance requirements The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-E04016A-0000 Registration Date/Time: 2022-04-06 13:39:28 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:47:29 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 5 of 5) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Tf?-VV►i 13a.drldw Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douv1.th (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E04016A-0000 Registration Date/Time: 2022-04-06 13:39:28 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:47:29 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 1 of 1) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Quality Insulation Installation (QII) applies to the entire thermal envelope of the building. By signing below, you are certifying that all of the applicable requirements in Residential Appendices (RA) 3.5 have been met. A qualified Home Energy Rating System (HERS) rater will need to verify its conformance for meeting the requirements of Sections 150.0, 150.1(c), and 110.7(a) and (b). Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-01Mi 13 bbs, Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv' d/ LP.a,L' Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E21010A-0000 Registration Date/Time: 2022-04-06 13:40:33 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:34 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 1 of 1) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Quality Insulation Installation (QII) applies to the entire thermal envelope of the building. By signing below, you are certifying that all of the applicable requirements in Residential Appendices (RA) 3.5 have been met. A qualified Home Energy Rating System (HERS) rater will need to verify its conformance for meeting the requirements of Sections 150.0, 150.1(c), and 110.7(a) and (b). Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-01Mi 13 bbs, Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv' d/ LP.a,L' Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E22011A-0000 Registration Date/Time: 2022-04-06 13:40:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:41 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 1 of 1) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Quality Insulation Installation (QII) applies to the entire thermal envelope of the building. By signing below, you are certifying that all of the applicable requirements in Residential Appendices (RA) 3.5 have been met. A qualified Home Energy Rating System (HERS) rater will need to verify its conformance for meeting the requirements of Sections 150.0, 150.1(c), and 110.7(a) and (b). Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-01Mi 13 bbs, Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv' d/ LP.a,L' Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E23012A-0000 Registration Date/Time: 2022-04-06 13:40:46 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:47 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 1 of 3) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Installed Lighting and Controls Select Yes or No according to whether your work on the project includes each of the following types of lighting and controls. See sections B through H for applicable requirements. 01 High Efficacy luminaires installed in any interior rooms. (See Section B.) No 02 JA8 compliant luminaires and controls installed in any interior rooms. (See Section B.) No 03 Recessed downlight luminaires in ceilings in any interior room (See Section C). No 04 Screw -based luminaires installed in any interior rooms (See Section D.) No 05 Lighting and controls in bathrooms (See Section E.) No 06 Lighting and controls in laundry rooms (See Section E.) No 07 Lighting and controls in utility rooms (See Section E.) No 08 Lighting and controls in garage (See Section E.) No 09 Outdoor lighting and controls (See Section H.) No 10 Blank electrical boxes installed more than 5 feet from finished floor. (See Section F.) No 11 Internally illuminated address signs. (See Section G.) No B. High Efficacy Luminaires and Controls This section does not apply to this project. C. Recessed Downlight Luminares in Ceilings This section does not apply to this project. D. Additional Luminaire Requirements This section does not apply to this project. Registration Number: 422-P010049211A-000-001-L01013A-0000 Registration Date/Time: 2022-04-06 13:40:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:30 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 2 of 3) E. Additional Lighting Controls This section does not apply to this project. F. Blank Electrical Boxes This section does not apply to this project. G. Address Signs This section does not apply to this project. H. Single Family Outdoor Lighting This section does not apply to this project. Registration Number: 422-P010049211A-000-001-L01013A-0000 Registration Date/Time: 2022-04-06 13:40:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:30 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: D cut/1. ' L ,a..i Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-L01013A-0000 Registration Date/Time: 2022-04-06 13:40:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:30 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 8) Project Name: Pepe Builds - Casita Enforcement Agency: La Quinta, City of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. General Information 01 Dwelling Unit Name Single Family Dwelling 02 Climate Zone 15 03 Dwelling Unit Total Conditioned Floor Area (ft2) 328 04 Number of Space Conditioning Systems in this dwelling unit. 1 05 Certificate of Compliance Type Performance (CF1R-PRF) 06 Method Used to Calculate HVAC Loads ACCA Manual J 07 Calculated Dwelling Unit Sensible Cooling Load (Btu/h) 24000 08 Calculated Dwelling Unit Heating Load (Btu/h) 24000 09 Dwelling Unit Number of Bedrooms 3 MCH-01a - Space Conditioning Systems Ducts and Fans - For use with Performance Certificate of Compliance Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 8) B. Design Space Conditioning (SC) System Component Specifications from CF1R This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project. 01 02 03 04 05 06 07 08 09 10 11 12 Zone Name SC System Identification or Name SC System Type Heating System Type Cooling System Type SC Fan Type Distribution System Type Required Thermostat Type Low Leakage Air -Handling Unit (LLAHU) Status Bypass Duct Status Cooling Zoning Type Cooling System Compressor Speed This field or section is not applicable Casital Heat pump heating cooling Ductless mini -split HP Ductless mini -split HP PSC Permanent Split Capacitor No ducts OCST per JA5 No, credit is not taken No Bypass Duct Not Zonal Single Speed Notes: C. Design Space Conditioning (SC) System Compliance Requirements from CF1R This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project. 01 02 03 04 05 06 07 08 09 10 SC System Identification or Name Heating Efficiency Type Minimum Heating Efficiency Value Heat Pump Heating Capacity at 47°F Heat Pump Heating Capacity at 17°F Minimum Cooling Efficiency SEER Minimum Cooling Efficiency EER Minimum Cooling System Airflow Rate (CFM/ton) Maximum Fan Efficacy (W/CFM) Minimum Duct R-Value Casital Heating Seasonal Performance Factor (HSPF) 6 25000 17500 14 12.2 350 This field or section is not applicable This field or section is not applicable Notes: Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 8) D. Installed Space Conditioning (SC) System Component Information 01 02 03 04 05 06 07 08 09 10 11 SC System Identification or Name SC System Location or Area Served Conditioned Floor Area Served by the System (ft2) Heating System Type Cooling System Type SC Fan Type Distribution System Type SC System Thermostat Type Cooling Zoning Type Cooling System Compressor Speed Type Central Fan Integrated (CFI) Ventilation System Status Casital CASITA 182 Electric Ductless mini -split AC PSC Permanent Split Capacitor No ducts Setback Not Zonal Single Speed Not a CFI system Notes: E. Installed Heating System Equipment Information (not heat pumps) 01 02 03 04 05 06 07 08 SC System Identification or Name SC System Location or Area Served Heating Efficiency Type Heating Efficiency Value Heating Unit Manufacturer Heating Unit Model Number Heating Unit Serial Number Rated Heating Capacity, Output (Btu/h) Casital CASITA Heating Seasonal Performance Factor (HSPF) 11 SAMSUNG RXS24XBT AR24TSFYBWKX 24000 Notes: Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 4 of 8) F. Installed Cooling System Outdoor Condensing Unit or Package Unit Equipment Information (not heat pumps) 01 02 03 04 05 06 07 08 09 SC System Identificatio n or Name SC System Location or Area Served Cooling Efficiency SEER Cooling Efficiency EER Condenser or Package Unit Manufacturer Condenser or Package Unit Model Number Condenser or Package Unit Serial Number System Rated Cooling Capacity at Design Conditions (Btu/h) Condenser Rated Nominal Capacity (ton) Casital CASITA 14 12.2 Samsung RXS24YBT AR24TSFYBWKX 24000 2 Notes: G. Installed Split System Indoor Coil or Fan Coil Unit Equipment Information (applicable to DX or hydronic heating/cooling coils or fan coil units) Systems with more than one indoor coil or fan coil unit (e.g. multi -split systems) shall provide information for each of the system indoor coils or fan coil units. 01 02 03 04 05 SC System Identification or Name SC System Location or Area Served Indoor Coil or Fan Coil Unit Manufacturer Indoor Coil or Fan Coil Unit Model Number Indoor Coil or Fan Coil Unit Serial Number Casital CASITA SAMSUNG RXS24XBT AR24TSFYBWKX Notes: H. Installed Heat Pump System - Split System Condensing Unit or Package Unit Equipment Information This section does not apply to this project. I. Installed Heat Pump System -Efficiency and Performance Compliance Information This section does not apply to this project. Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 8) J. Installed Duct System Information This section does not apply to this project. K. Installed Air Filter Device Information Mandatory requirements for air filter devices are specified Section 150.0(m)12. This section does not apply to this project. L. Air Filter Device Requirements This section does not apply to this project. M. HERS Verification Requirements 01 02 03 04 05 06 07 08 09 10 11 12 SC System Identificati on or Name SC System Location or Area Served MCH-20 Duct Leaka a g Test MCH-21 Duct Location Verification MCH-22 AHU Fan Efficacy (W/cfm) MCH-23 AHU Airflow Rate (cfm/ton) MCH-25 Refrigerant Charge g MCH-26 Rated SC System Equipment Verification MCH-27 IAQ Mechanical Ventilation MCH-28 Return Duct Design Table 150.0-B or C MCH-29 Supply Duct Surface Area R-Value Buried Ducts MCH30 Ventilation Cooling Credit Casital CASITA No No No No No No Yes No No No Notes: Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 8) N. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)1 and 2). 04 Furnace Temperature Rise: Central forced -air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet -to -outlet temperature rise specification. See Section 150.0(h)4. 05 Standby Losses and Pilot Lights: Fan -type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Liquid Line Filter Drier: If applicable, a liquid line filter drier shall be installed according to the manufacturer's specifications. Section 150.0(h)3B 10 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 8) N. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures Note. Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. 11 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)1. 12 Connections and Closures: All installed air -distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 13 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 14 The thermostat shall be installed in accordance with the manufacturers published installation specifications 15 First stage of heating shall be assigned to heat pump heating. 16 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 8 of 8) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: "Term/ 13cw, Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: t cut/1, i Leath Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-M01008A-0000 Registration Date/Time: 2022-04-06 13:34:40 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:42:41 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 1 of 7) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Title 24, Part 6, Section 150.0(o) Ventilation for Indoor Air Quality. All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Equation and table numbering on this form corresponds to the numbering for that information in the published ANSI/SHRAE Standard 62.2-2010. A. Dwelling Mechanical Ventilation - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single Family 03 Project scope Newly constructed building 04 Total Conditioned Floor Area of Dwelling Unit (For addition projects the conditioned floor area equals existing area plus addition area. ) 328 05 Number of bedrooms in dwelling unit (For addition projects the number of bedrooms equals the existing bedrooms plus addition bedrooms) 3 06 Ventilation Operation Schedule Continuous 07 Whole -Building Ventilation Rate Calculation Method Fan Ventilation Rate Method (4.1.1) 08 Whole Building Ventilation System Type Standalone - Exhaust 09 IAQ Fan Location Note: Non -dwelling units do not meet the definition for a dwelling unit as defined in Section 100.1(b). Non -dwelling units are not designed to provide independent living facilities and do not provide permanent provisions for living, sleeping, eating, cooking and sanitation. MCH-27a - Continuous Ventilation Airflow - Fan Ventilation Rate Method B. Whole -Building Continuous Ventilation - Fan Ventilation Rate Method A mechanical supply system, exhaust system, or combination thereof shall provide whole -building ventilation with outdoor air each hour at no less than the rate in equation 4.1a. 01 Required Continuous Whole -Building Ventilation Rate (Qfan) 33.28 02 Installed Continuous Whole -Building Ventilation Rate 200 Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 2 of 7) C. Compliance Statement 01 Building passes continuous whole -building ventilation rate test Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 3 of 7) D. Local Mechanical Exhaust System - Fan selection and duct design criteria for compliance Local mechanical exhaust fans shall be installed in each kitchen and bathroom. Delivered local ventilation rates: • All local ventilation rates have been measured using a flow hood, flow grid, or other airflow measuring device and meet the requirements of 62.2 Tables 5.1 or 5.2. OR • The airflow rating at a pressure of 0.25 in. w.c. of a certified fan is assumed because the local ventilation system duct sizing meets the prescriptive requirements of 62.2 Table 5.3, or manufacturer's design criteria. Table 5.1 Intermittent Local Ventilation Exhaust Airflow Rates Application Airflow Notes Kitchen 100 cfm Vented range hood (including appliance -range hood combinations) required if exhaust fan flow is less than 5 ACH. Bathroom 50 cfm Table 5.2 Continuous Local Ventilation Exhaust Airflow Rates Application Airflow Notes Kitchen 5 ACH Based on Kitchen volume. Bathroom 20 cfm Table 5.3 Prescriptive Duct Sizing Requirements Duct Type Flex Duct Smooth Duct Fan Rating cfm @ 0.25 in. w.g. 50 80 100 125 50 80 100 125 Maximum Allowable Duct Length (ft) Diameter, (in) Flex Duct Smooth Duct 3 X X X X 5 X X X 4 70 3 X X 105 35 5 X 5 NL 70 35 20 NL 135 85 55 6 NL NL 125 95 NL NL NL 145 7andabove NL NL NL NL NL NL NL NL This table assumes no elbows. Deduct 15 ft of allowable duct length for each turn, elbow, or fitting. Interpolation and extrapolation in 62.2 Table 5.3 is not allowed. For airflow values not listed, use the next higher value. This table is not applicable for airflow > 125 cfm. NL = no limit on duct length of this size. X = not allowed, any length of duct of this size with assumed turns, elbows, fittings will exceed the rated pressure drop. Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 4 of 7) E. Other Requirements The items listed below (6.1 through 6.8) correspond to the information given in ASHRAE 62.2 Section 6 "Other Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.5) for information describing these "Other Requirements". The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable. 01 6.1 Transfer Air. Measures shall be taken to minimize air movement across envelope components to occupiable spaces from garages, unconditioned crawl spaces, and unconditioned attics. Supply and balanced ventilation systems shall be designed and constructed to provide ventilation air directly from the outdoors. 02 6.2 Instructions and Labeling. Information on the ventilation design and/or ventilation systems installed, instructions on their proper operation to meet the requirements of this standard, and instructions detailing any required maintenance (similar to that provided for HVAC systems) shall be provided to the owner and the occupant of the dwelling unit. Controls shall be labeled as to their function (unless that function is obvious, such as toilet exhaust fan switches). See Chapter 13 of Guideline 24 2 for information on instructions and labeling. 03 6.3 Clothes Dryers. Clothes dryers shall be exhausted directly to the outdoors 04 6.4 Combustion and Solid -Fuel Burning Appliances. Combustion and solid -fuel burning appliances must be provided with adequate combustion and ventilation air and vented in accordance with manufacturer installation instructions, NFPA 54 ANSI 2223.1, National Fuel Gas Code, NFPA 31, Standard for the Installation of Oil -Burning Equipment, or NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid -Fuel Burning Appliances, or other equivalent code acceptable to the building official. Where atmospherically vented combustion appliances or solid -fuel burning appliances are located inside the pressure boundary, the total net exhaust flow of the two largest exhaust fans (not including a summer cooling fan intended to be operated only when windows or other air inlets are open) shall not exceed 15 cfm/100 ft2 (75 Lps/100 m2) of occupiable space when in operation at full capacity. If the designed total net flow exceeds this limit, the net exhaust flow must be reduced by reducing the exhaust flow or providing compensating outdoor airflow. Atmospherically vented combustion appliances do not include direct -vent appliances. 05 6.5 Garages. When an occupiable space adjoins a garage, the design must prevent migration of contaminants to the adjoining occupiable space. Air seal the walls, ceilings, and floors that separate garages from occupiable space. To be considered air sealed, all joints, seams, penetrations, openings between door assemblies and their respective jambs and framing, and other sources of air leakage through wall and ceiling assemblies separating the garage from the residence and its attic area shall be caulked, gasketed, weather stripped, wrapped, or otherwise sealed to limit air movement. Doors between garages and occupiable spaces shall be gasketed or made substantially airtight with weather stripping. 06 6.6 Ventilation Opening Area. Spaces shall have ventilation openings as listed below. Such openings shall meet the requirements of Section 6.8 07 6.7 Minimum Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 ft (3 m) in length and through a thermal conditioning component, except evaporative coolers, shall be provided with a filter having a designated minimum efficiency of MERV 6, or better, when tested in accordance with ANSI ASHRAE Standard 52.2, Method of Testing General Ventilation Air -Cleaning Devices for Removal Efficiency by Particle Size, or a minimum Particle Size Efficiency of 50 percent in the 3.0-10 µm range in accordance with AHRI Standard 680, Performance Rating of Residential Air Filter Equipment. The system shall be designed such that all recirculated and mechanically supplied outdoor air is filtered before passing through the thermal conditioning components. The filter shall be located and installed in such a manner as to facilitate access and regular service by the owner. Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 5 of 7) E. Other Requirements The items listed below (6.1 through 6.8) correspond to the information given in ASHRAE 62.2 Section 6 "Other Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.5) for information describing these "Other Requirements". The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable. 08 6.8 Air Inlets. Air inlets that are part of the ventilation design shall be located a minimum of 10 ft (3 m) from known sources of contamination such as a stack, vent, exhaust hood, or vehicle exhaust. The intake shall be placed so that entering air is not obstructed by snow, plantings, or other material. Forced air inlets shall be provided with rodent insect screens (mesh not larger than 1/2 inch). 09 6.9 Carbon Monoxide Detectors. A carbon monoxide alarm shall be installed in each dwelling unit in accordance with NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 14, and shall be consistent with requirements of applicable laws, codes, and standards. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. F. Air Moving Equipment The items listed below (7.1 through 7.3) correspond to the information given in ASHRAE 62.2 Section 7Air-Moving Equipment. Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.6) for information describing these requirements in more detail. The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 7.1 through 7.3 if applicable. 01 7.1 Selection and Installation. Ventilation devices and equipment shall be tested and listed in accordance with specific standards. Installations of systems or equipment shall be carried out in accordance with manufacturers' design requirements and installation instructions. 02 7.2 Sound Ratings for Fans. Ventilation fans shall be rated for sound at no less than the minimum airflow rate required by this standard, as noted below. These sound ratings shall be at a minimum of 0.1 in. w.c. (25 Pa) static pressure. 7.2.1 Whole Building or Continuous Ventilation Fans. These fans shall be rated for sound at a maximum of 1.0 sone. 7.2.2 Intermittent Local Exhaust Fans. Fans used to comply with Section 5.2 shall be rated for sound at a maximum of 3 sone, unless their maximum rated airflow exceeds 400 cfm (200 L/s). (Some exceptions may apply.) 03 7.3 Multibranch Exhaust Ducting. If more than one of the exhaust fans in a dwelling unit shares a common exhaust duct, each fan shall be equipped with a back draft damper to prevent the recirculation of exhaust air from one room to another through the exhaust ducting system. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 6 of 7) G. Multifamily Buildings -Other Requirements The items listed below correspond to the information given in ASHRAE 62.2 Section 8 "Multifamily Buildings". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.5) for information describing these requirements in more detail. The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 8, if applicable. 8.2 Whole -Building Mechanical Ventilation. For multifamily buildings, the term "building" in Section 4 refers to a single dwelling unit. 8.4.1 Transfer Air. Measures shall be taken to minimize air movement across envelope components separating dwelling units, including sealing penetrations in the common walls, ceilings, and floors of each unit and by sealing vertical chases adjacent to the units. All doors between dwelling units and common hallways shall be gasketed or made substantially airtight. 8.4.1.1 Compliance. One method of demonstrating compliance with Section 8.4.1 shall be to verify a leakage rate below a maximum of 0.2 cfm/ ft2 (100 Lis per 100 m2) of the dwelling unit envelope area (i.e., the sum of the area of the walls 01 between dwelling units, exterior walls, ceiling and floor) at a test pressure of 50 Pa by a blower door test. The test shall be conducted with the dwelling unit as if it were exposed to outdoor air on all sides, top, and bottom by opening doors and windows of adjacent dwelling units. 8.5.1 Exhaust Ducts. Exhaust fans in separate dwelling units shall not share a common exhaust duct. Exhaust inlets from more than one dwelling unit may be served by a single exhaust fan downstream of all the exhaust inlets if the fan is designated and intended to run continuously or if each inlet is equipped with a back -draft damper to prevent cross -contamination when the fan is not running. 8.5.2 Supply Ducts. Supply outlets to more than one dwelling unit may be served by a single fan upstream of all the supply outlets if the fan is designed and intended to run continuously or if each supply outlet is equipped with a back -draft damper to prevent cross -contamination when the fan is not running. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 7 of 7) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-M 27009A-0000 Registration Date/Time: 2022-04-06 13:40:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:20 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 1 of 5) Project Name: Pepe Builds - Casita Enforcement Agency: La Quinta, City of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. General Information 01 Dwelling Unit Name Single Family Dwelling B. Design Dwelling Unit Water Heating Systems Information This table reports the water heating system features that were specified on the registered CF1R compliance document for this project. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Water Heating System ID or Name Water Heating System Type Water -Heater Type # of Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss (%) Exterior Insul. R-Value Central DHW System Distribution Type Dwelling Unit DHW System Distribution yPe Type DHW Sys 1 Domestic Hot Water (DHW) Small Instantaneous 1 0.10 Natural Gas Btu/Hr 200000.00 Energy Factor (EF) 0.99 This field or section is not applicable This field or section is not applicable This field or section is not applicable Parallel Piping C. Installed Dwelling Unit Water Heating Systems Information 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Water Heating System ID or Name Water Heating System Type Water -Heater Type # of Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss (%) Exterior Insul. R-Value Central DHW System Distribution Type Dwelling Unit DHW System Distribution ype Type DHW Sys 1 Domestic Hot Water (DHW) Small Instantaneous 1 0.1 Natural Gas Btu/Hr 200000 Energy Factor (EF) 0.99 This field or section is not applicable This field or section is not applicable This field or section is not applicable Parallel Piping Registration Number: 422-P010049211A-000-001-B02014A-0000 Registration Date/Time: 2022-04-06 13:35:05 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:43:06 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 2 of 5) D. Installed Water Heater Manufacturer Information 01 02 03 Water Heating System ID or Name Manufacturer Model Number DHW Sys 1 A 0 SMITH 656418 E. Mandatory Measures For All Domestic Hot Water Distribution Systems 01 Equipment shall meet the applicable requirements of the Appliance Efficiency Regulations (Section 110.3(b)1). 02 Unfired Storage Tanks are insulated with an external R-12 or combination of R-16 internal and external Insulation. (Section 110.3(c)4). 03 The following pipes are insulated, to the thicknesses required by Table 120.3A, except for those sections of pipe that are subject to one of the exceptions below: (RA4.4.1) • The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. • All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. • All piping associated with a domestic hot water recirculation system regardless of the pipe diameter, except when cold water return is used in a demand system. • Piping from the heating source to storage tank or between tanks. • Piping buried below grade. • All hot water pipes from the heating source to the kitchen fixtures. The following sections of pipe do not have to be insulated: (RA4.4.1) • Piping installed in interior or exterior walls that is surrounded on all sides by at least 1 inch of insulation. • Piping installed in attics with a minimum of 4 inches (10 cm) of attic insulation on top • Piping that penetrates framing members shall not be required to have pipe insulation for the distance of the framing penetration. Metal piping that penetrates metal framing shall use grommets, plugs, wrapping or other insulating material to assure that no contact is made with the metal framing. Insulation shall butt securely against all framing members. 04 Piping buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. (Section 150.0(j)) 05 All elbows and tees shall be fully insulated. (RA4.4.1) 06 Where insulation is required, no piping shall be visible due to insulation voids, and all insulation shall fit tightly to the pipe. (RA4.4.1) Registration Number: 422-P010049211A-000-001-B02014A-0000 Registration Date/Time: 2022-04-06 13:35:05 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:43:06 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 3 of 5) E. Mandatory Measures For All Domestic Hot Water Distribution Systems 07 For Gas or Propane Water Heaters: Ensure the following are installed (Section 150.0(n)) 1. A 120V electrical receptacle is within 3 feet from the water heater and accessible with no obstructions 2. A Category III or IV vent, or a Type B vent with straight pipe between outside and water heater 3. A condensate drain no more than 2 inches higher than the base on water heater for natural draining 4. A gas supply line with capacity of at least 200,000 Btu/Hr The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. F. Standard Distribution System Requirements (trunk and branch systems only) This section does not apply to this project. G. Pipe Insulation Credit Requirements (for trunk and branch Hot Water system) This section does not apply to this project. H. Parallel Piping Requirements 01 Each central manifold has 15 feet or less of pipe between manifold and water heater (RA 4.4.15) 02 For manifolds that include valves, the manifold must be readily accessible in accordance with the plumbing code. (RA 4.4.4) 03 Hot water distribution system piping from the manifold to the fixtures and appliances must take the most direct path. For instance, piping from a second story manifold cannot supply the first floor. (RA 4.4.4) 04 The hot water distribution piping must be separated by at least 2 inches from any other hot water supply piping, and at least 6 inches from any cold water supply piping. Alternatively, the hot water supply piping must be insulated to the thicknesses shown in TABLE 120.3-A. (RA 4.4.4) The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010049211A-000-001-B02014A-0000 Registration Date/Time: 2022-04-06 13:35:05 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:43:06 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 4 of 5) I. Point of Use Requirements This section does not apply to this project. J. Recirculation Non -Demand Controls Requirements This section does not apply to this project. K. Demand Recirculation Manual Control Requirements This section does not apply to this project. L. Demand Recirculation Sensor Control Requirements This section does not apply to this project. Registration Number: 422-P010049211A-000-001-B02014A-0000 Registration Date/Time: 2022-04-06 13:35:05 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:43:06 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 5 of 5) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-VV►i 13a.drld w Company: MLC Building Performance Signature Date: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douvilth (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-B02014A-0000 Registration Date/Time: 2022-04-06 13:35:05 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:43:06 Schema Version: rev 20180426 CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 1 of 6) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Air Infiltration And Insulation Installation (Qii) - Framing Stage 01 The requirements below cover the required air sealing and installation of insulation that must occur in the framing stage. 02 An air barrier is required in all thermal envelope assemblies to limit air movement between unconditioned/outside spaces and conditioned/inside spaces and must meet one of the following: 1. Using individual materials that have an air permeance not exceeding 0.004 cfm/ft2 under pressure differential of 0.3 in w.g. (1.57 psf) (0.02 L/s.m2 at 75 pa) when tested in accordance with ASTM E2178; or • A list of example materials meeting the air permenace testing performance levels of 1 above is available in RA3.5.2 2 Using assemblies of materials and components that have an average air leakage not to exceed 0.04 cfm/ft2 under a pressure differential of 0.3 in w.g. (1.57 psf) (0.2 L/s.m2 at 75 pa) when tested in accordance with ASTM E2357, ASTM E1677, ASTM E1680 or ASTM E283, or 3. Testing the complete building and demonstrating that the air leakage rate of the building envelope does not exceed 0.4 cfm/ft2 at a pressure differential of 0.3 in w.g. (1.57 psf) (2.0 L/m2 at 75 pa) in accordance with ASTM E779 or an equivalent approved method. 03 Air Barrier Material Installed 04 Verification Status Pass - all applicable requirements are met 05 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. B. Raised Floor 01 All gaps in the raised floor are sealed. 02 All chases sealed at floor level using a hard cover and the hard covers are sealed. 03 All Plumbing and electrical wires that penetrate the floor are sealed. 04 Subfloor sheathing is glued or sealed at all exterior panel edges, to create a continuous air tight subfloor. 05 Verification Status Pass - all applicable requirements are met 06 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: 422-P010049211A-000-001-E21004A-E21A Registration Date/Time: 2022-04-06 13:40:35 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:36 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 2 of 6) C. Walls/Knee Walls 01 All penetrations through the exterior wall air barrier are sealed to provide an air -tight envelope to unconditioned spaces such as the outdoors, attic, garage and crawl space. 02 Exterior wall air barrier is sealed to the top plate and bottom plate in each stud bay. 03 All electrical boxes including knockouts that penetrate the air barrier to unconditioned space are sealed. 04 All openings in top and bottom plate, including all interior and exterior walls, to unconditioned space are sealed. Such as holes drilled for electrical and plumbing. 05 Exterior bottom plates (all stories) are sealed to the floor using the appropriate sealing method. 06 All gaps around windows and doors are sealed. Proper sealant used was specified by window manufacturer. 07 Rim Joists all gaps and openings fully sealed. 08 Fan exhaust ducts that run between conditioned floors to exterior walls have a damper at the exterior wall. 09 Metal tie downs are insulated between exterior framing and tie down. 10 Insulation is installed in hard to access wall stud cavities, such as corner channels, wall intersections are insulated to the proper R-value prior to exterior sheathing, or the exterior stucco lath. 11 Insulation is installed behind tub, when located against exterior walls. shower, fireplace enclosures, and exterior stairwells to the R-value listed on the CF1R Insulation is required to be installed before tub, shower, and fireplace are installed. 12 A solid air barrier is installed on the interior wall from floor to ceiling tub, shower, and fireplace enclosures are installed in exterior walls. Insulation in contact on all six sides of air barrier on exterior walls. 13 All single -member window and door headers shall be insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a minimum of R-5 for all other assemblies. Insulation is to be placed between the interior face of the header and inside surface of the interior wall finish. If continuous exterior rigid insulation is used an insulated header is not required. No header insulation is required for single -member headers that are the same width as the wall, so long as the entire wall has at least R-2 insulation. 14 Knee walls have solid and sealed blocking at the bottom, top, left side and right side of the knee wall. 15 Verification Status Pass - all applicable requirements are met 16 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Ceiling/Attic 01 For vented attics much of the ceiling air barrier is verified after the ceiling drywall is installed using the ENV-22. 02 For non -vented attics ensure all penetrations through the roof deck and gable ends are sealed and air tight. Registration Number: 422-P010049211A-000-001-E21004A-E21A Registration Date/Time: 2022-04-06 13:40:35 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-04-06 13:48:36 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 3 of 6) D. Ceiling/Attic 03 All eave vents are covered with a rigid ventilation baffle that maintains the Net free -ventilation area. 04 All dropped ceilings and soffits are covered with hard covers and sealed to framing. 05 All chases are covered with hard covers and sealed to framing. 06 HVAC ducts that travel down a chase the chase is sealed at the ceiling level. 07 Chimney and Flue require sheet metal flashing. The flashing shall be sealed to the chimney or flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 08 All Eave/soffit baffles are installed to stop air movement around the baffle and into insulation. Net free -ventilation of the eave/soffit shall be maintained. 09 Double walls that open to attic are covered with an air barrier and cover has an air tight seal to the framing. 10 Verification Status Pass - all applicable requirements are met 11 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Conditioned Space Above Or Adjacent To Garage Air Barrier 01 All penetrations in the subfloor above the garage into conditioned space must follow the raised floor air barrier requirements above. 02 Infiltration between the space above the garage and subfloor is prevented by one of the following methods: • Seal all edges of garage ceiling (typically drywall) at the perimeter of the garage to create a continuous air tight surface between the garage and adjacent conditioned envelope. Seal all plumbing, electric and mechanical penetrations between the garage and the adjacent conditioned space. For an open -web truss, airtight blocking is added on four sides of the garage perimeter. Insulation can be placed on the garage ceiling. • Seal band joist above the wall at the garage to conditioned space transition. Seal all subfloor seams and penetrations between the conditioned space and the garage. Insulation must be placed in contact of subfloor below conditioned space. 03 Verification Status Pass - all applicable requirements are met 04 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. F. Walls For Attached Porch, Attic, Double Wall 01 All walls that separate conditioned and unconditioned space includes a continuous air barrier on the interior and exterior wall. Registration Number: 422-P010049211A-000-001-E21004A-E21A Registration Date/Time: 2022-04-06 13:40:35 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-04-06 13:48:36 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 4 of 6) F. Walls For Attached Porch, Attic, Double Wall 02 Exterior wall, air barrier required at the intersection of the porch and exterior wall when there is conditioned space on the other side. The exterior wall where the attic attaches to the conditioned space does includes an air barrier. 03 Truss framing blocking is used at the top and bottom of each wall/roof section. 04 Verification Status Pass - all applicable requirements are met 05 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. G. Cantilevered Floor Air Barrier 01 Airtight blocking is installed between joists where the wall rim joist would have been located in the absence of a cantilever. 02 Exterior sheathing is installed to the bottom of the cantilever so that there is a continuous air and weather barrier for the cantilever. The cantilevered joist must be insulated to the same R value as would be required for the subfloor prior to closing. 03 Any gaps, cracks or penetrations in the air barrier of the cantilever are sealed. Can lights in the cantilever are IC and AT rated and properly sealed to sheathing. 04 Verification Status Pass - all applicable requirements are met 05 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. H. Multifamily Air Barrier 01 Multifamily buildings must meet all air sealing requirements for single family buildings listed above. 02 Each dwelling unit must be air sealed to stop air movement from one unit to another. 03 Floor AND Ceiling of each Dwelling Unit: All penetrations through the floor and ceiling of each unit are sealed including, electric and gas utilities, water pipes, drain pipes, fire protection service pipes, communication wiring. 04 Elevator penthouse, mechanical penthouse, stairwell doors, roof access hatch, plumbing stacks sealed to reduce air transfer from attached spaces. 05 Common Walls: Bottom plate between units is sealed to the subfloor. All penetrations in the common walls are sealed including electrical boxes, wiring and plumbing penetrations. Perpendicular Interior walls that open into the common walls are sealed. 06 Vertical Chases for garbage chutes, elevator shafts, and HVAC ducting plumbing must be sealed to the floor and ceiling of each unit to stop air movement up and around the chase due to stack effect. Registration Number: 422-P010049211A-000-001-E21004A-E21A Registration Date/Time: 2022-04-06 13:40:35 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-04-06 13:48:36 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 5 of 6) H. Multifamily Air Barrier 07 Vertical Chases such as garbage chutes, elevator shafts, and HVAC ducting plumbing, wiring etc. must be sealed to stop air movement through the chase to the surrounding spaces. 08 Common Hallways - Penetrations between dwelling unit and common hallways are sealed, doors to the dwelling unit are gasketed or made substantially airtight . 09 Verification Status Pass - all applicable requirements are met 10 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. I. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010049211A-000-001-E21004A-E21A Registration Date/Time: 2022-04-06 13:40:35 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:36 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 6 of 6) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7 oin' BCA, 1/14.44, Company: MLC Building Performance Date Signed: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN 10140 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E21004A-E21A Registration Date/Time: 2022-04-06 13:40:35 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:36 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 1 of 3) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 For typical vented attics where the insulation is at the roof deck ceiling air barrier must be verified after the ceiling drywall is installed and before attic insulation is installed. If SPF will be used in the attic this can be considered the air barrier. Soffit and chases must still be covered and chimneys and flues require metal flashing. Buildings with a Non vented attic all air sealing requirements appropriate for the roof must be verified. A. Ceiling Inspection - Vented Attics 01 If there is a continuous air barrier at the ceiling level; All opening into walls, drops, chasses, double walls are sealed. Examples are below. 02 Chimney and Flue require sheet metal flashing. The flashing shall be sealed to the chimney or flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 03 All penetration through the top plate of interior and exterior walls are sealed. 04 All penetrations shall be sealed to the surrounding drywall or have a secondary air barrier created around the fixture; with the exception of fire sprinklers. 05 All installed recessed light fixtures that penetrate the ceiling to unconditioned space, or where insulation is present, are rated to be Insulation Contact and Air Tight (IC and AT) which allows direct contact with insulation. Housing is sealed to the drywall. 06 Exhaust fan housing is sealed to surrounding drywall and all holes and seams in the housing sealed. 07 All soffits and chases are covered with a hard cover that is sealed to the framing with caulk or foam. 08 Double walls that open to attic are covered and the cover sealed to the framing. 09 Attic Access forms airtight seal from conditioned space to unconditioned space. Vertical attic access requires mechanical compression using screws, or latches. 10 Knee walls require solid and sealed blocking at the bottom, top left side and right side of the knee wall. When the knee wall is placed on top of a subfloor the open cavity below the subfloor and the ceiling below are sealed. 11 HVAC ducts that travel down a chase the chase are sealed at the ceiling level. 12 HVAC boots that penetrate the ceiling are sealed to the surrounding drywall. 13 All top plates of interior and exterior walls sealed to drywall. 14 Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation. 15 There must be a dam placed at the exterior edge of all kneewalls and all edges of insulation to stop air movement through insulation. 16 Verification Status: Pass - all applicable requirements are met Registration Number: 422-P010049211A-000-001-E22005A-E22A Registration Date/Time: 2022-04-06 13:40:42 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-04-06 13:48:43 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 2 of 3) A. Ceiling Inspection - Vented Attics 17 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. B. Roof Inspection - Non -Vented Attics 01 There is a continuous air barrier at the roof deck and gable ends. 02 Chimney and Flue require sheet metal flashing at the roof deck. The flashing is sealed to the chimney or flue with fire rated caulk. The flashing is sealed to the surrounding framing. 03 All penetrations for plumbing, electrical etc in the roof deck and gable ends are sealed. 04 Verification Status: Pass - all applicable requirements are met 05 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. C. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010049211A-000-001-E22005A-E22A Registration Date/Time: 2022-04-06 13:40:42 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:43 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E22005A-E22A Registration Date/Time: 2022-04-06 13:40:42 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:43 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 1 of 7) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Quality Insulation Installation (QII) Preparation For Insulation 01 Air barrier installation and preparation for insulation was done and verified at framing stage prior to insulation being installed. Where applicable, CF3R-ENV21 and 22 compliance documents have been signed off. 02 All structural framing areas shall be insulated in a manner that resists thermal bridging of the assembly separating conditioned from unconditioned space. Structural bracing, tie -downs, and framing of steel, or specialized framing used to meet structural requirements of the CBC are allowed and must be insulated. These areas shall be called out on the building plans with diagrams and or specific design drawings indicating the R-value of insulation and fastening method to be used. It is recommended that spray foam be used. 03 All insulation was installed to the manufactures insulation installation instructions. 04 Verification Status: Pass - all applicable requirements are met 05 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. B. Quality Of All Installed Insulation 01 Installed insulation R-values is the same or greater than specified on the CF1R. 02 No gaps or voids between the insulation and framing. 03 Gaps between studs shall be filled with insulation. 04 Batt - ensure the ends are cut so there are no gaps. 05 Batt - Insulation is cut around obstructions like electrical boxes and no gaps exist. 06 Batt - insulation is not compressed (no stuffing of the insulation into the cavity. 07 Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors. 08 An air barrier is installed at all exposed faces of batt, loose fill and SPF insulation. 09 Loose -fill insulation installed to the minimum installed weight per ft2 per the manufacturer labeled R-value specification. 10 SPF insulation shall be spray -applied to fully adhere to structural assembly framing, floor and ceiling joists, and other framing surfaces within the construction cavity. 11 SPF - with multiple layers applied, each foam lift (i.e. spray application) adheres to the substrate and foam interfaces. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:50 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 2 of 7) B. Quality Of All Installed Insulation 12 SPF - if values other than R-5.8 per inch for closed -cell SPF (ccSPF) and R-3.6 per inch for open -cell SPF (ocSPF) are used, the ICC Evaluation Service Report (ESR) number (e.g. ESR-xxxx) will be documented in the CF2R-ENV-03. 13 ccSPF in areas where an air barrier is required the foam is at least 2 inches thick. 14 ocSPF depressions in the foam insulation surface is not greater than 1-inch of the required thickness provided these depressions do not exceed 10 percent of the surface area being insulated. 15 ocSPF insulation completely fills cavities of 2x4 inch framing or less. 16 ocSPF cavities greater than 2x4 inch framing are filled to the thickness that meets the required R-value used for compliance. 17 SPF installed as an air barrier is sprayed at a minimum thickness of 5.5 inches for open cell and 2.0 inches for closed cell. 18 The insulation installer provided a CF2R-ENV-03. Labels or specification/data sheets are attached to the CF2R-ENV-03 for each insulating material. The material datasheet for the installed material meets the performance specifications of the required R-Values. Blown in material also includes insulation material bag labels or coverage charts. 19 Verification Status: Pass - all applicable requirements are met 20 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. C. Ceiling/Roof Insulation Quality 01 Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams or baffles. 02 Insulation is in direct contact with ceiling so there are no gaps between the ceiling and the insulation. 03 Chimneys and flues (except for zero clearance) require a sheet metal collar around the stack. The collar must be at least as tall as the depth of the insulation. The collar shall be 1 inch from the chimney or flue for double wall vents, and 6 inches from the chimney/flue for single wall vents unless the manufacturer requires otherwise. The collar must be sealed to the ceiling with high temperature sealant to prevent air leakage. The insulation is in contact with the sheet metal collar. 04 Required eave ventilation shall not be obstructed - the net free -ventilation area of the eave vent is maintained 05 Eave vent baffles are installed to prevent air movement under or into the ceiling insulation 06 Recessed downlights are covered with insulation. If they are not covered to the same depth as required by the CF1R for ceiling insulation then a area weighted calculation is required. Recessed downlights are AT and IC rated. 07 SPF insulation shall not be applied directly to recessed lighting fixtures. Recessed downlights where SPF insulation is installed shall: (a) be covered with a minimum of 1.5 inches of mineral fiber insulation, or (b) be enclosed in a box fabricated from 1/4 inch plywood, 18 gauge metal, 3/8 inch hard board or gypboard. Hard board or gypboard does not cause a recessed downlights to meet the zero clearance insulation contact requirements. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:50 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page3of7) C. Ceiling/Roof Insulation Quality 08 Walkways and mechanical platforms are insulated to the same R-value as required by the CF1R for ceiling insulation. If not, an area weighted calculation is completed and turned in with this compliance document. 09 Soffits, chasses and drop ceiling areas have a sealed hard cover and the insulation is in direct contact with the hard cover. 10 Knee walls - an air dam the full depth of the ceiling insulation is added to the exterior edge of the knee wall so the ceiling insulation overlaps the knee wall to the full depth of the ceiling insulation. 11 Attic access doors are insulated to the same R-value required by the CF1R for roof insulation and the insulation is permanently attached using adhesive or mechanical fasteners. The preferred method is rigid insulation. 12 Attic access forms an airtight seal from conditioned space to unconditioned space. Vertical attic access requires mechanical compression using screws, or latches. 13 Attic access must have a dam around the access to at least the same depth as the insulation. 14 Insulation batts must be cut to fit around cross bracings and truss webs. 15 Attic rulers appropriate to the material are installed and evenly distributed throughout the attic to verify depth (one ruler for every 250 ft2) The rulers are clearly readable from the attic access and scaled to read inches of insulation and the R-value installed. 16 Loose -fill and SPF insulation - a HERS rater shall measure the installed thickness (including low and high areas) and density of insulation in at least 6 random locations on roof/ceilings and floors to ensure minimum thickness levels and installed density necessary to meet the R-value specified on the Certificate of Compliance, and consistency with the manufacturer coverage chart. 17 Steel -framed knee walls, skylight shafts, and gable ends, external surfaces of steel studs are covered with insulation 18 Verification Status: Pass - all applicable requirements are met 19 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Wall Insulation 01 Batts, loose fill mineral fiber, mineral and natural wool, and cellulose: fills cavity and is in contact with air barrier on six sides. 02 ocSPF: completely fill cavities of 2x4 inch framing or less. Not required to fill cavities greater than 2x4 inch framing unless required to meet R-value. 03 ccSPF: insulation is not required to fill the cavities of framed assemblies unless required to meet R-value. 04 Double walls and bump -outs - insulation fills the cavity, or additional air barrier is installed so the insulation fills the cavity and is in contact with the insulation on all six sides unless SPF is used. Insulation shall be installed on the exterior of the double walls or bump -outs. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-04-06 13:48:50 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 4 of 7) D. Wall Insulation 05 Low expanding foam used around windows and doors, if allowed by the manufacturer. If not allowed fill cavity with insulation. Batts are not allowed to be stuffed into space. 06 Electrical panel in exterior insulated wall the panel is air tight and insulation is installed behind the panel. 07 Skylight shafts and attic knee wall insulation must meet all the requirements for walls and is in contact with the air barrier on six sides unless SPF is used. 08 Skylight shafts and attic kneewalls insulation shall be in full contact with the drywall or other interior wall finish. Batt insulation must be cut to fit around 2x4 framing that are laid flat. 09 Skylight shafts and attic kneewalls shall be completely enclosed by vertical and horizontal framing, including horizontal plates at top and bottom of the insulation. 10 Band/Rim joists are insulated to the same R-value as the wall. 11 Verification Status: Pass - all applicable requirements are met 12 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Raised Floor Insulation Quality 01 Insulation is in full contact with subfloor. 02 Insulation hangers are spaced at 18 inches or less, insulation hangers do not compress insulation. 03 Netting or mesh can be used if the cavity under the floor is filled and in contact with the subfloor. 04 When daylight basements are adjacent to crawlspaces, if the basement is conditioned the walls adjacent to the crawlspace are insulated to the R-value listed on the CF1R. This includes framed stem walls, and vertical concrete retaining walls. 05 If access to the crawlspace is from the conditioned area the raised floor includes an airtight insulated access hatch. Where possible locate crawl space access from the exterior. 06 Verification Status: Pass - all applicable requirements are met 07 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. F. Floor Above Garage Insulation Quality 01 Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage house wall. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:50 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page5of7) F. Floor Above Garage Insulation Quality 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 Netting or mesh can be used if the cavity under the floor is filled and in contact with the subfloor. 04 If air barrier is at the perimeter of the garage below the conditioned subfloor then the insulation may be placed on the garage ceiling. Perimeter of subfloor must also be insulated. 05 Verification Status: Pass - all applicable requirements are met 06 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. G. Cantilevered Floor Insulation Quality 01 Insulation is in full contact with cantilevered subfloor. Insulation hangers are spaced at 18 inches or less, insulation hangers do not compress insulation. Netting or mesh can be used if the cavity under the floor is filled and in contact with the subfloor. 02 Sealed Blocking shall be installed between joists where the wall rim joist would have been located in the absence of a cantilever. Insulation shall be placed on both sides of this block. 03 Verification Status: Pass - all applicable requirements are met 04 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. H. Attached Porch Roof Insulation Quality 01 Exterior wall at the intersection of the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is used at the top and bottom of each wall/roof section and insulated. 03 Verification Status: Pass - all applicable requirements are met 04 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:50 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page6of7) I. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:50 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 7 of 7) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-E23006A-E23A Registration Date/Time: 2022-04-06 13:40:49 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:50 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 1 of 3) Project Name: Pepe Builds - Casita Enforcement Agency: City La Quinta, of Permit Number: 2022- Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Title 24, Part 6, Section 150.0(o) Ventilation for Indoor Air Quality. All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Equation and table numbering on this form corresponds to the numbering for that information in the published ANSI/SHRAE Standard 62.2-2010. A. Dwelling Mechanical Ventilation - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single family 03 Project scope Newly constructed building 04 Total Conditioned Floor Area of Dwelling Unit (For addition projects the conditioned floor area equals existing area plus addition area. ) 328 05 Number of bedrooms in dwelling unit (For addition projects the number of bedrooms equals the existing bedrooms plus addition bedrooms) 3 06 Ventilation Operation Schedule Continuous 07 Whole -Building Ventilation Rate Calculation Method Fan Ventilation Rate Method (4.1.1) 08 Whole Building Ventilation System Type Standalone - Exhaust 09 IAQ Fan Location MCH-27a - Continuous Ventilation Airflow - Fan Ventilation Rate Method B. Whole -Building Continuous Ventilation - Fan Ventilation Rate Method A mechanical supply system, exhaust system, or combination thereof shall provide whole -building ventilation with outdoor air each hour at no less than the rate in equation 4.1a. 01 Required Continuous Whole -Building Ventilation Rate (Qfan) 33.28 02 Installed Continuous Whole -Building Ventilation Rate 200 C. Compliance Statement 01 Building passes continuous whole -building ventilation rate test Registration Number: 422-P010049211A-000-001-M 27003A-M 27A Registration Date/Time: 2022-04-06 13:40:24 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:25 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 2 of 3) D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010049211A-000-001-M 27003A-M 27A Registration Date/Time: 2022-04-06 13:40:24 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:25 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-04-06 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-04-06 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010049211A-000-001-M 27003A-M 27A Registration Date/Time: 2022-04-06 13:40:24 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-04-06 13:48:25 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. DATE DOCUMENT CHEERS REGISTRY PROJECT STATUS REPORT PROJECT SUMMARY Project Name: Address: City, State, Zip: Building Department: Permit Number: Building Energy Code: Pepe Builds - Casita 77-285 Calle Chihuahua La Quinta, CA 92253 La Quinta, City of 2022- 2016 Standards HERS VERIFIABLE MEASURES ENERGY CODE COMPLIANCE CERTIFICATE OF COMPLIANCE (CF1R) DATE 04/06/2022 04/06/2022 DOCUMENT CF1 R-PRF-01-E C F 1 R-S RA-01-E TITLE Performance Compliance Solar New Construction Scan to Validate COMPLETE O COMPLETE O REGISTRATION NUMBER 422-P010049211A-000-000-0000000-0000 422-P010049211A-R01002A CERTIFICATE OF INSTALLATION (CF2R) TITLE 04/06/2022 CF2R-ENV-01-E Fenestration 04/06/2022 CF2R-ENV-03-E Insulation Installation 04/06/2022 CF2R-ENV-04-E Roofing Radiant Barrier 04/06/2022 CF2R-ENV-21-H QII 04/06/2022 CF2R-ENV-22-H QII 04/06/2022 CF2R-ENV-23-H QII 04/06/2022 CF2R-LTG-01-E Lighting 04/06/2022 CF2R-MCH-01a-E HVAC, Ducts and Fans D04 changed from "DuctlessSplitHP" to "Electric" D05 changed from "DuctlessSplitHP" to "DuctlessSplitAC" 04/06/2022 CF2R-MCH-27a-H Mechanical Ventilation 04/06/2022 CF2R-PLB-02a-E Single Family Hot Water - continued on next page - REGISTRATION NUMBER 422-P010049211A-000-001-E01017A-0000 422-P010049211A-000-001-E03015A-0000 422-P010049211A-000-001-E04016A-0000 422-P010049211A-000-001-E21010A-0000 422-P010049211A-000-001-E22011A-0000 422-P010049211A-000-001-E23012A-0000 422-P010049211A-000-001-L01013A-0000 422-P010049211 A-000-001-M01008A-0000 422-P010049211A-000-001-M27009A-0000 422-P010049211A-000-001-B02014A-0000 NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. STATUS O O STATUS Page 1 of 2 CERTIFICATE OF VERIFICATION (CF3R) DATE 04/06/2022 04/06/2022 04/06/2022 04/06/2022 DOCUMENT TITLE CF3R-ENV-21-H QII CF3R-ENV-22-H QII CF3R-ENV-23-H QII CF3R-MCH-27a-H CHEERS Mechanical Ventilation REGISTRATION NUMBER 422-P01004921 E21A 422-P01004921 E22A 422-P01004921 E23A 422-P01004921 M27A 1A-000-001-E21004A- 1 A-000-001-E22005A- 1 A-000-001-E23006A- 1 A-000-001-M27003A- Scan to Validate NOTICE: This compliance summary report has been generated by a registration platform provided by CHEERS using information that has been uploaded to that registration platform by third parties that are not affiliated or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this certificate. STATUS !n� r Page 2 of 2 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 1 of 9 GENERAL INFORMATION 01 Project Name Single Family Residence 02 Calculation Description Title 24 Analysis 03 Project Location 77-285 Calle Chihuahua 04 City La Quinta 05 Standards Version Compliance 2017 06 Zip Code 92253 07 Compliance Manager Version BEMCmpMgr 2016.3.1 (1149) 08 Climate Zone CZ15 09 Software Version EnergyPro 7.2 10 Building Type Single Family 11 Front Orientation (deg/Cardinal) 0 12 Project Scope Newly Constructed 13 Number of Dwelling Units 1 14 Total Cond. Floor Area (ft2) 2112 15 Number of Zones 1 16 Slab Area (ft2) 2112 17 Number of Stories 1 18 Addition Cond. Floor Area(ft2) n/a 19 Natural Gas Available Yes 20 Addition Slab Area (ft2) n/a 21 Glazing Percentage (%) 25.8% COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below ENERGY USE SUMMARY 04 05 06 07 08 Energy Use (kTDV/ft2-yr) Standard Design Proposed Design Compliance Margin Percent Improvement Space Heating 2.36 7.12 -4.76 -201.7% Space Cooling 104.22 94.36 9.86 9.5% IAQ Ventilation 1.11 1.11 0.00 0.0% Water Heating 6.06 9.28 -3.22 -53.1% Photovoltaic Offset ---- 0.00 0.00 ---- Compliance Energy Total 113.75 111.87 1.88 1.7% Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 2 of 9 ENERGY DESIGN RATING Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV energy. Because EDR includes consideration of components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen). As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable energy can both be seen EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR 55.0 54.3 0.0 54.3 • Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite. ■ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite. Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ15 (CALGreen A4.203.1.2.3) including on -site photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System and QII must be verified. • Notes: • Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering (NEM) rules REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Window overhangs and/or fins • Central parallel piping HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building components tables below. Building -level Verifications: • High quality insulation installation (QII) • IAQ mechanical ventilation Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM HVAC Distribution System Verifications: • Duct Sealing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • -- None -- Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 3 of 9 BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Single Family Residence 2112 1 3 1 0 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Whole House Conditioned Whole Housel 2112 9 DHW Sys 1 n/a OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2) Window & Door Area (ft2) Tilt (deg) Front Wall Whole House R-21 Wall 0 Front 800 156.595 90 Left Wall Whole House R-21 Wall 90 Left 600 55 90 Rear Wall Whole House R-21 Wall 180 Back 800 31.5 90 Right Wall Whole House R-21 Wall 270 Right 700 297.401 90 Roof 2 Whole House R-38 Roof Attic n/a n/a 2108.6 n/a n/a OPAQUE SURFACES — Cathedral Ceilings 01 02 03 04 05 06 07 08 09 10 Name Zone Type Orientation Area (ft2) Skylight Area (ft2) Roof Rise (x in 12) Roof Reflectance Roof Emittance Cool Roof Roof Whole House R-38 Roof Atticl Front 3.5 3.4 0 0.8 0.75 Yes ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Whole House Attic RoofWhole House Ventilated 0 0.8 0.75 Yes Yes Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 4 of 9 FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 Name Type Surface (Orientation -Azimuth) Width (ft) Height (ft) Multiplier Area (ft2) U-factor SHGC Exterior Shading Window Window Front Wall (Front-0) 3.0 8.0 1 24.0 0.40 0.30 Insect Screen (default) Window 2 Window Front Wall (Front-0) 3.4 1.5 0.98 5.0 0.40 0.30 Insect Screen (default) Window 3 Window Front Wall (Front-0) 6.5 1.5 1.005 9.8 0.40 0.30 Insect Screen (default) Window 4 Window Front Wall (Front-0) 6.5 1.5 1.005 9.8 0.40 0.30 Insect Screen (default) Window 5 Window Front Wall (Front-0) 13.5 8.0 1 108.0 0.48 0.20 Insect Screen (default) Window 6 Window Left Wall (Left-90) 5.0 1.5 1 7.5 0.40 0.30 Insect Screen (default) Window 7 Window Left Wall (Left-90) 5.0 1.5 1 7.5 0.40 0.30 Insect Screen (default) Window 8 Window Left Wall (Left-90) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) Window 9 Window Left Wall (Left-90) 4.0 5.0 1 20.0 0.40 0.30 Insect Screen (default) Window 10 Window Rear Wall (Back-180) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 11 Window Rear Wall (Back-180) 9.0 1.5 1 13.5 0.40 0.30 Insect Screen (default) Window 12 Window Rear Wall (Back-180) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 13 Window Rear Wall (Back-180) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 14 Window Right Wall (Right-270) 5.0 7.4 0.992 36.7 0.40 0.30 Insect Screen (default) Window 15 Window Right Wall (Right-270) 5.0 7.4 0.992 36.7 0.40 0.30 Insect Screen (default) Window 16 Window Right Wall (Right-270) 5.0 1.5 1 7.5 0.40 0.30 Insect Screen (default) Window 17 Window Right Wall (Right-270) 5.0 1.5 1 7.5 0.40 0.30 Insect Screen (default) Window 18 Window Right Wall (Right-270) 6.5 1.5 1.005 9.8 0.40 0.30 Insect Screen (default) Window 19 Window Right Wall (Right-270) 6.5 1.5 1.005 9.8 0.40 0.30 Insect Screen (default) Window 20 Window Right Wall (Right-270) 13.5 8.0 1 108.0 0.48 0.20 Insect Screen (default) Window 21 Window Right Wall (Right-270) 4.0 1.5 1 6.0 0.40 0.30 Insect Screen (default) Window 22 Window Right Wall (Right-270) 3.9 1.5 0.974 5.7 0.40 0.30 Insect Screen (default) Window 23 Window Right Wall (Right-270) 8.0 8.0 1 64.0 0.40 0.30 Insect Screen (default) Window 24 Window Right Wall (Right-270) 3.9 1.5 0.974 5.7 0.40 0.30 Insect Screen (default) Skylight Skylight Roof (Front-0) 1 3.4 0.36 0.26 Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 5 of 9 OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Overhang Left Fin Right Fin Window Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 2 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 3 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 4 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 5 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 6 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 7 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 8 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 9 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 10 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 11 8 0.1 8 8 0 0 0 0 0 0 0 0 0 Window 12 6 0.1 6 6 0 0 0 0 0 0 0 0 0 Window 13 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 14 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 15 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 16 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 17 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 18 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 19 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 20 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 21 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 22 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 23 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Window 24 2 0.1 2 2 0 0 0 0 0 0 0 0 0 Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 6 of 9 OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 Construction Name Surface Type Construction Type Framing Total Cavity R-value Winter Design U-factor Assembly Layers Attic RoofWhole House Attic Roofs Wood Framed Ceiling 2x4 Top Chord of Roof Truss @ 24 in. O.C. none 0.644 • Cavity / Frame: no insul. / 2x4 Top Chrd • Roof Deck: Wood Siding/sheathing/decking • Roofing: Light Roof (Asphalt Shingle) R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. O.C. R 21 0.069 • Inside Finish: Gypsum Board • Cavity / Frame: R-21 / 2x6 • Exterior Finish: 3 Coat Stucco R-38 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.025 • Inside Finish: Gypsum Board • Cavity/Frame: R-9.1 /2x4 • Over Ceiling Joists: R-28.9 insul. R-38 Roof Atticl Cathedral Ceilings Wood Framed Ceiling 2x4 @ 24 in. O.C. R 38 0.036 • Inside Finish: Gypsum Board • Cavity / Frame: R-38 / 2x4 • Roof Deck: Wood Siding/sheathing/decking • Roofing: Light Roof (Asphalt Shingle) SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R-value & Depth Carpeted Fraction Heated Slab -on -Grade Whole House 2112 545 None 1 No BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Not Required n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%) DHW Sys 1 DHW Central Parallel Piping DHW Heater 1 (1) 1 .0% Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 7 of 9 WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Name Heater Element Type Tank Type Number of Units Tank Volume (gal) Uniform Energy Factor / Energy Factor / Efficiency Input Rating / Pilot / Thermal Efficiency Tank Insulation R-value (Int/Ext) Standby Loss / Recovery Eff First Hour Rating / Flow Rate NEEA Heat Pump Brand / Model / Other Tank Location or Ambient Condition DHW Heater 1 Gas Small Storage 1 50 0.65 EF <= 75 kBtu/hr R-0/R-0 0 n/a n/a n/a SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 SC Sys Name System Type Heating Unit Name Cooling Unit Name Fan Name Distribution Name Whole House1 Other Heating and Cooling System Heating Component 1 Cooling Component 1 HVAC Fan 1 Air Distribution System 1 HVAC - HEATING UNIT TYPES 01 02 03 04 Name System Type Number of Units Efficiency Heating Component 1 CntrlFurnace 1 80 AFUE HVAC - COOLING UNIT TYPES 01 02 03 04 05 06 07 08 Name System Type Number of Units Efficiency EER SEER Zonally Controlled Compressor Type HERS Verification Cooling Component 1 SplitAirCond 1 13 16 Not Zonal Single Speed Cooling Component 1-hers-cool HVAC COOLING - HERS VERIFICATION 01 02 03 04 05 06 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Charge Cooling Component 1-hers-cool Required 350 Required Required Required HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 Name Type Duct Leakage Insulation R-value Duct Location Bypass Duct HERS Verification Air Distribution System 1 DuctsAttic Specified Lower Leakage Target 8 Attic None Air Distribution System 1-hers-dist Registration Number: 422-P010008074A-000-000-0000000-0000 Registration Date/Time: 01/19/2022 14:25 CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-01162019-1149 HERS Provider: CHEERS Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 8 of 9 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low -leakage Air Handler Air Distribution System 1-hers-dist Required 6.0 Not Required Not Required Not Required Not Required Required HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) HERS Verification HVAC Fan 1 Single Speed PSC Furnace Fan 0.58 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficiency (Watts/CFM) HVAC Fan 1-hers-fan Required 0.58 IAQ (Indoor Air Quality) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification SFam IAQVentRpt 51 0.25 Default 0 Required Registration Number: 422-P010008074A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 01/19/2022 14:25 HERS Provider: CHEERS Report Version - CF1 R-01162019-1149 Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD Project Name: Single Family Residence Calculation Description: Title 24 Analysis Calculation Date/Time: 16:44, Thu, Sep 17, 2020 Input File Name: Pepe Builds 77285 Calle Chihuahua.ribdl6x CF1 R-PRF-01 Page 9 of 9 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Joan Hacker Documentation Author Signature: JoYAAyV 1- CGOICRAE Company: Joan Hacker Signature Date: 01/19/2022 Address: 72875 Fred Waring Drive CEA/HERS Certification Identification (If applicable): City/State/Zip: Palm Desert, CA 92260 Phone: 760-345-1352 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Joan Hacker Responsible Designer Signature: J019(/ cc,c,kor Company: Joan Hacker Date Signed: 01/19/2022 Address: 72875 Fred Waring Drive License: City/State/Zip: Palm Desert, CA 92260 Phone: 760-345-1352 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-000-0000000-0000 CA Building Energy Efficiency Standards - 2016 Residential Compliance Registration Date/Time: 01/19/2022 14:25 HERS Provider: CHEERS Report Version - CF1 R-01162019-1149 Report Generated at: 2020-09-17 16:45:11 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-SRA-01-E Solar Ready Buildings - New Construction (Page 1 of 2) Project Name: Pepe Builds Chihuahua Date Prepared: 2022-01-21 A. General Information Do not use this form to show solar ready compliance for hotel/motel occupancies and high-rise multifamily buildings with ten stories or fewer and all other nonresidential buildings with three stories or fewer. Instead, use form N RCC-SRA-01-E 01 Building Type Single family 02 Method of Compliance Residence not in an applicable subdivision B. Building Meets the Solar Ready Requirements This section does not apply to this project. C. Residence not in an Applicable Subdivision 01 The single family residence is located in a subdivision with fewer than ten single family residences, or where the application for a tentative subdivision map for the residences was deemed complete by the enforcement agency, before January 1, 2014. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. D. Permanently Installed Solar Photovoltaic (PV) System This section does not apply to this project. E. Permanently Installed Solar Water Heating System This section does not apply to this project. F. Smart Thermostats and Alternative Efficiency Measure This section does not apply to this project. G. Roof is Designed for Vehicle Traffic or Parking or for Heliport (Applies to Low-rise Multifamily only) This section does not apply to this project. Registration Number: 422-P010008074A-R01001A CA Building Energy Efficiency Standards 2016 Residential Compliance Registration Date/Time: 2022-01-21 06:29:43 HERS Provider: CHEERS Report Version: 2018.0.001 Report Generated: 2022-01-21 06:36:51 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF COMPLIANCE CF1R-SRA-01-E Solar Ready Buildings - New Construction (Page 2 of 2) Documentation Author's Declaration Statement 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 'r Bat,( , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: David Leal Responsible Designer Signature: 'vim Lec 2• Company : Compressor Air Conditioning and Heating Date Signed: 2022-01-21 Address: 47892 Pheonix Street License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-R01001A CA Building Energy Efficiency Standards 2016 Residential Compliance Registration Date/Time: 2022-01-21 06:29:43 HERS Provider: CHEERS Report Version: 2018.0.001 Report Generated: 2022-01-21 06:36:51 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 1 of 5) Project Name: Pepe Builds Chihuahua Enforcement Agency: La Quinta, City of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible. Alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. The signer agrees that all applicable Mandatory Measures were met. Temporary labels are not to be removed before verification by the building inspector. A. Fenestration Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) and SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacture r/Brand Fenestration z Area (ft) Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/S pecial Features Window owens 24.0000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 2 owens 5.0000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 3 owens 9.8000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 4 owens 9.8000 0 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 5 owens 108.0000 0 No 0.48 NFRC 0.2 NFRC Standard bug screens Registration Number: 422-P010008074A-000-001-E01001A-0000 Registration Date/Time: 2022-01-21 06:15:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 2 of 5) A. Fenestration Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) and SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacture r/Brand Fenestration Area (ft2) Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/S pecial Features Window 6 owens 7.5000 90 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 7 owens 7.5000 90 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 8 owens 20.0000 90 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 9 owens 20.0000 90 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 10 owens 6.0000 180 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 11 owens 13.5000 180 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 12 owens 6.0000 180 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 13 owens 6.0000 180 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 14 owens 36.7000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Registration Number: 422-P010008074A-000-001-E01001A-0000 Registration Date/Time: 2022-01-21 06:15:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 3 of 5) A. Fenestration Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) and SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacture r/Brand Fenestration Area (ft2) Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/S pecial Features Window 15 owens 36.7000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 16 owens 7.5000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 17 owens 7.5000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 18 owens 9.8000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 19 owens 9.8000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 20 owens 108.0000 270 No 0.48 NFRC 0.2 NFRC Standard bug screens Window 21 owens 6.0000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 22 owens 5.7000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Window 23 owens 64.0000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Registration Number: 422-P010008074A-000-001-E01001A-0000 Registration Date/Time: 2022-01-21 06:15:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 4 of 5) A. Fenestration Glazing Includes all Windows, Skylights, Greenhouse or Bay Windows and Glazed Doors.Note: If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 glass in door, it is assumed to meet the minimum required U-factor (0.32) and SHGC (0.25). If meeting Exception 1 to 150.1(c)3A, Installing <= 3 ft2 tubular skylight, it is assumed to meet the minimum required U-factor (0.55) and SHGC (0.30). 01 02 03 04 05 06 07 08 09 10 11 12 Tag ID Manufacture r/Brand Fenestration Area (ft2) Orientation Chromogenic U-factor Source SHGC Source Fenestration Type Exterior Shading Devices Comments/S pecial Features Window 24 owens 5.7000 270 No 0.4 NFRC 0.3 NFRC Standard bug screens Skylight owens 3.0000 0 No 0.36 NFRC 0.26 NFRC Skylight None B. Fenestration Installation 01 For new construction, installed window U-factor and SHGC values should be equal to or less than listed on the CF1R. 02 For existing buildings the U-factor and SHGC values should be the same or better than the required Energy Commission prescriptive requirements. 03 Temporary labels should not be removed until verified by the building inspector. 04 The fenestration product manufacturer's installation specifications shall be followed when installing these products. The space between the fenestration product and rough opening shall be completely filled with insulation. If batt insulation is used, it is cut to size and placed properly around the fenestration product. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-E01001A-0000 Registration Date/Time: 2022-01-21 06:15:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-01-E Fenestration Installation (Page 5 of 5) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-VV►i 13a.drld w Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douv1.th (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E01001A-0000 Registration Date/Time: 2022-01-21 06:15:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 1 of 8) Project Name: Pepe Builds Chihuahua Enforcement Agency: La Quinta, City of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Medium and light density SPF manufacturers claim various R-values per inch. In California the maximum R-value that can be claimed for ccSPF is an R-value of 5.8 per inch and for ocSPF is an R-value of 3.6 per inch unless documentation is provided showing that the product and/or manufacturer has a current ICC Evaluation Service Report (ESR) that shows compliance with Acceptance Criteria for Spray -Applied Foam Plastic Insulation-AC377. Note: The Energy Standards Section 110.7 requires that 'all joints, penetrations and other openings in the building envelope that are potential sources of air leakage shall be caulked, gasketed, weather stripped, or otherwise sealed to limit infiltration and exfiltration.' In areas where spray foam (SPF) insulation is used, the SPF can be considered the air barrier. Other than rigid board insulation, all other forms of insulation are not considered as an air barrier. A. Roof/Ceiling Insulation 01 02 03 04 05 06 07 08 09 10 I.D. Manufacturer and Brand Assembly/Frami ng Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value Roof owens Wood Framed Ceiling 4.7 2x4 @ 24 in. O.C. Cellulose This field or section is not applicable 38 2.5 21 Roof 2 owens Wood Framed Ceiling 15.12 2x4 @ 24 in. 0 C Cellulose This field or section is not applicable 38 5.5 This field or section is not applicable Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 2 of 8) B. Wall Insulation 01 02 03 04 05 06 07 08 09 10 I.D. Manufacturer and Brand Assembly/Frami ng Material Assembly Thickness (inches) Framing Size and Spacing Insulation Type ESR Number Core/Cavity Insulation R-value Insulation Depth (inches) Continuous Insulation R-value Front Wall Wood Framed Wall 6.88 2x6 @ 16 in. O.C. Cellulose This field or section is not applicable 21 This field or section is not applicable This field or section is not applicable Left Wall Wood Framed Wall 6.88 2x6 @ 16 in. O.C. C Cellulose This field or section is not applicable 21 This field or section is not applicable This field or section is not applicable Rear Wall Wood Framed Wall 6.88 2x6 @ 16 in. C O.C. Cellulose This field or section is not applicable 21 This field or section is not applicable This field or section is not applicable Right Wall Wood Framed Wall 6.88 2x6 @ 16 in. O.C. C Cellulose This field or section is not applicable 21 This field or section is not applicable This field or section is not applicable C. Mass Insulation This section does not apply to this project. D. Raised Floor Insulation This section does not apply to this project. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 3 of 8) E. Slab Floor/Perimeter Insulation (See Section F. For Insulation Requirements For Heated Slabs) This section does not apply to this project. F. Heated Slabs Insulation 01 All heated slabs shall be insulated as required by Section 110.8(g). Footings must meet required insulation levels. 02 Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-15 require R-5, and climate zone 16 requires R-10. 03 Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires R-10 vertical and R-7 horizontal. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. G. Minimum Mandatory Measures 01 Insulation - 110.8(a): All installed Insulation is certified and listed with Department of Consumer Affairs, "Standards for Insulating Material". 02 Insulation - 110.8(b): Urea formaldehyde foam insulation is protected by 4 mil polyethylene vapor retarder. 03 Insulation - 110.8(c): Flame spread and smoke density requirements of CBC are met. 04 Raised Floor - 150.0(d): All raised wood -frame floor have a minimum R-19 insulation or equivalent U-factor 05 Slab Floor/Perimeter - 150.0(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and is protected from physical damage and UV Tight deterioration. 06 Above Grade Exterior Wall - 150.0(c)1: All 2x4 wood -frame walls have a minimum R-13 insulation or equivalent U-factor. 07 Above Grade Exterior Wall - 150.0(c)2: All 2x6 wood -frame walls have a minimum R-19 insulation or equivalent U-factor. 08 Ceiling/Rafter Roof - 150.0(a)1: All wood -frame ceiling have a minimum R-22 insulation or equivalent U-factor. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 4 of 8) G. Minimum Mandatory Measures 09 Vapor Retarder - 150(g)1: In Climate Zones 1 through 16, the earth floor of unvented crawl space shall be covered with a Class I or Class II vapor retarder. This requirement shall also apply to controlled ventilation crawl space for buildings complying with the Exception to Section 150.0(d). 10 Vapor Retarder - 150(g)2: In Climate Zones 14 and 16, a Class I or Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior walls, vented attics and unvented attics with air -permeable insulation. 11 Heated Slabs - 110.8(g): All heated slabs shall be insulated as required. • Insulation shall be installed from the top of the slab, down 16 inches or to the frost line, whichever is greater. Climate zones 1-5 require R-5, and climate zone 16 requires R-10. • Alternatively, vertical insulation from top of slab at inside edge of outside wall down to the top of the horizontal insulation. Horizontal insulation from the outside edge of the vertical insulation extending 4 feet toward the center of the slab in a direction normal to the outside of the building in plain view. Climate zones 1-5 require R-5, and climate zone 16 requires R-10 vertical and R-7 horizontal. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. H. Installed Insulation 01 Installed insulation R-values are the same or greater than listed on the CF1R. 02 No gaps or voids between the insulation and framing. 03 No gaps between the sides or ends of batt insulation. 04 Loose -fill insulation must be installed to the minimum installed weight per square foot (density) of the manufacturer's cut sheet for the proposed R-value. 05 Batt insulation is not compressed (no stuffing of the insulation into the cavity) and is installed to its full thickness. 06 Insulation is cut around obstructions such as electrical boxes. 07 Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors. 08 Band joists are insulated to the same R-value as the wall. 09 In all narrow cavities the insulation shall be cut to fit or filled with expanding foam. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 5 of 8) H. Installed Insulation 10 Insulation was installed per manufacturer instructions. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. I. Wall Insulation 01 When allowed by manufacturer, low expanding foam shall be used to fill gaps and voids around windows and doors. If not, the cavity must be air tight and filled completely with insulation. Batt insulation must be cut to width. No stuffing allowed. 02 Install wall insulation before installing tubs, showers and fireplaces. 03 Electric panels on walls separating conditioned and unconditioned space are sealed and insulated behind the panel with rigid insulation or expanding foam. 04 All walls of interior closets vented to the outside for HVAC or water heating equipment have the same R-value and air barrier as the exterior walls and ceiling. Doors are insulated and weather stripped. 05 Ducting not allowed in exterior walls unless insulated to R6 or greater and the insulation and duct are not crushed. Ducting not allowed in 2x4 wall assemblies. 06 Corner channels, wall intersections, and double sided shear walls insulated to the required R-value before enclosing the wall. 07 Insulation that does not fill the cavity placed against exterior air barrier. 08 Band joists are insulated to the same R-value as the walls. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. J. Ceiling Roof Insulation 01 Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams/baffles. 02 Insulation is in direct contact with ceiling, so there are no gaps between the ceiling and the insulation. 03 For chimneys and flues, the insulation is in contact with the sheet metal collar. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 6 of 8) J. Ceiling Roof Insulation 04 Can lights are covered with insulation to the same depth as required by the CF1R for ceiling insulation. If not an area weighted calculation is required to be turned in with this compliance document. 05 Walkways and mechanical platforms insulated to the same R-value as required for the ceiling. If not an area weighted calculation is required to be turned in with this compliance document. 06 Insulate soffits by adding an air barrier and cover with insulation, or insulate the entire soffit including floor and walls. 07 Knee walls and skylight shafts are insulated to the wall R-value and in full contact with the interior air barrier. If framing on these surfaces is laid flat batt insulation is cut to fit around the framing. Batt insulation is not allowed to be draped over the framing. 08 Attic access doors insulated to the same R-value as ceiling. The insulation is permanently attached using adhesive or mechanical fasteners. 09 Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation. 10 Batt insulation cut to fit around cross bracings and truss webs in attic. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. K. Raised Floor Insulation 01 Insulation in full contact with subfloor. 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 04 If the basement is conditioned the walls adjacent to the crawlspace must meet minimum wall R-value requirements. This includes framed stem walls, and vertical concrete retaining walls. 05 If access to the crawl space is from the conditioned area, the raised floor must have an airtight insulated access hatch. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 7 of 8) L. Floor Above Garage Insulation 01 Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage/house wall. 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 04 If air barrier is at the perimeter of the garage, below conditioned subfloor, the insulation is placed on the garage ceiling. The perimeter of subfloor is also insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. M. Cantilevered Floor Insulation 01 Insulation in full contact with cantilevered subfloor. Insulation hangers spaced at 18 inches or less, insulation hangers do not compress insulation. 02 If netting or mesh is used, the cavity under the floor is filled and in contact with the subfloor. 03 Sealed blocking is installed between joists where wall rim joist would be located in the absence of a cantilever. Insulation is placed on both sides of this block. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. N. Attached Porch Roof Insulation 01 The exterior insulated wall at the intersection with the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is at the top and bottom of each wall/roof section and insulated. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-03-E Insulation Installation (Page 8 of 8) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-VV►i 13a.drld w Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douvilth (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E03002A-0000 Registration Date/Time: 2022-01-21 06:16:21 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 1 of 5) Project Name: Pepe Builds Chihuahua Enforcement Agency: La Quinta, City of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Radiant Barrier 01 Brand Name and product number owens 02 Installation Type Attached to underside of roof deck, with perforations to allow moisture/vapor transfer 03 Total Attic Area (ft2) 2000 B. Schedule of Lower Vents The Net Free Area (NFA) of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non -manufactured products, assume that the net free area is one third of the total aperture area. 01 02 03 04 Type of Vent For instance, eyebrow vent, eave vent, round vent NFA per vent (in2) (Manufacturers Specification Sheet) Number of Vents Installed Total NFA Per Vent Type (in2) Eyebrow vent 100 5 500 C. Schedule of Upper Vents The Net Free Area of a manufactured product is stated on the packaging or on the manufacturer's specification data sheet. For non -manufactured products, assume that the net free area is one third of the total aperture area. 01 02 03 04 Registration Number: 422-P010008074A-000-001-E04003A-0000 Registration Date/Time: 2022-01-21 06:19:06 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 2 of 5) C. Schedule of Upper Vents Type of Vent For instance, eyebrow vent, eave vent, round vent NFA per vent (in2)/Per Linear Foot (Manufacturer Specification Sheet) Total NFA Per Vent Type (in2) Other 100 5 500 D. Required Vent Area 01 Combined NFA of installed upper and lower vents (in2) 1000 02 Minimum required combined NFA of upper and lower vents (in2) 960 03 NFA of installed upper vents (in2) 500 04 Minimum required NFA of upper vents (in2) 288 05 Compliance Statement Building complies E. Radiant Barrier and Attic Ventilation - Additional Requirements Radiant Barrier 01 Radiant barrier must be installed on all vertical surfaces in the attic including gable ends. 02 The emittance of the radiant barrier shall be less than or equal to 0.05 as tested with ASTM C1371, or E408. 03 The product shall meet all requirements for California certified insulation materials (radiant barriers) of the Department of Consumer Affairs, Bureau of Home Furnishings and Thermal Insulation, as specified by CCR, Title 24, Part 12, Chapter 12-13, Standards for Insulating Material 04 When determining the Total Attic Area, the area over unconditioned spaces such as the garage is included when the attic spaces are connected Lower Vents Registration Number: 422-P010008074A-000-001-E04003A-0000 Registration Date/Time: 2022-01-21 06:19:06 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 3 of 5) E. Radiant Barrier and Attic Ventilation - Additional Requirements 05 Lower vents are within one foot of the eave. Upper Vents 06 Upper vents are within three feet of the ridge. Vent Area 07 The NFA of upper vents must be within required NFA range of upper vents Note: per Exception to R806.2 of the CBC Title 24, Part2, VoI.2.5, if the net free ventilating area is less than 1:150, then the upper ventilation must be at least 40% and no more than 50%. Part 2 contains additional requirements that must be met if the area is less than 1:150. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. F. Roofing Products (Cool Roof) Installation Information 01 02 03 04 05 06 07 08 09 10 11 12 Tag/ID Roof Pitch CRRC Product ID Number Product type CRRC Listed Aged Solar Reflectance Installed Required Initial Solar Reflectance Aged Solar Reflectance Thermal Emittance SRI Aged Solar Reflectance Thermal Emittance SRI 521452225 Roof pitch is greater than 2 :12 412897545 Clay roof tiles No .23 .51 .2 11245554 0.8 .52 1145252 G. Roofing Products (Cool Roof) - Additional Requirements 01 Any roof area covered by building integrated photovoltaic panels and solar thermal panels are exempt from the above Cool Roof requirements 02 Liquid field applied coatings must comply with installation criteria from section 110.8(i)4 Registration Number: 422-P010008074A-000-001-E04003A-0000 Registration Date/Time: 2022-01-21 06:19:06 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 4 of 5) G. Roofing Products (Cool Roof) - Additional Requirements 03 Mass roof 25 Ib/ft2 or greater: Mass roofs are not required to have a cool roof even if the climate zone specifies minimum performance requirements The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-E04003A-0000 Registration Date/Time: 2022-01-21 06:19:06 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-04-E Roofing Radiant Barrier (Page 5 of 5) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: Tf?-VV►i 13a.drldw Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douv1.th (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E04003A-0000 Registration Date/Time: 2022-01-21 06:19:06 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 1 of 1) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Quality Insulation Installation (QII) applies to the entire thermal envelope of the building. By signing below, you are certifying that all of the applicable requirements in Residential Appendices (RA) 3.5 have been met. A qualified Home Energy Rating System (HERS) rater will need to verify its conformance for meeting the requirements of Sections 150.0, 150.1(c), and 110.7(a) and (b). Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-01Mi 13 bbs, Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv' d/ LP.a,L' Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E21004A-0000 Registration Date/Time: 2022-01-21 06:19:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 1 of 1) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Quality Insulation Installation (QII) applies to the entire thermal envelope of the building. By signing below, you are certifying that all of the applicable requirements in Residential Appendices (RA) 3.5 have been met. A qualified Home Energy Rating System (HERS) rater will need to verify its conformance for meeting the requirements of Sections 150.0, 150.1(c), and 110.7(a) and (b). Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-01Mi 13 bbs, Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv' d/ LP.a,L' Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E22005A-0000 Registration Date/Time: 2022-01-21 06:19:26 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 1 of 1) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Quality Insulation Installation (QII) applies to the entire thermal envelope of the building. By signing below, you are certifying that all of the applicable requirements in Residential Appendices (RA) 3.5 have been met. A qualified Home Energy Rating System (HERS) rater will need to verify its conformance for meeting the requirements of Sections 150.0, 150.1(c), and 110.7(a) and (b). Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-01Mi 13 bbs, Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv' d/ LP.a,L' Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E23006A-0000 Registration Date/Time: 2022-01-21 06:19:29 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:58 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Installed Lighting and Controls Select Yes or No according to whether your work on the project includes each of the following types of lighting and controls. See sections B through H for applicable requirements. 01 High Efficacy luminaires installed in any interior rooms. (See Section B.) No 02 JA8 compliant luminaires and controls installed in any interior rooms. (See Section B.) No 03 Recessed downlight luminaires in ceilings in any interior room (See Section C). No 04 Screw -based luminaires installed in any interior rooms (See Section D.) No 05 Lighting and controls in bathrooms (See Section E.) No 06 Lighting and controls in laundry rooms (See Section E.) No 07 Lighting and controls in utility rooms (See Section E.) No 08 Lighting and controls in garage (See Section E.) No 09 Outdoor lighting and controls (See Section H.) No 10 Blank electrical boxes installed more than 5 feet from finished floor. (See Section F.) No 11 Internally illuminated address signs. (See Section G.) No B. High Efficacy Luminaires and Controls This section does not apply to this project. C. Recessed Downlight Luminares in Ceilings This section does not apply to this project. D. Additional Luminaire Requirements This section does not apply to this project. Registration Number: 422-P010008074A-000-001-L01014A-0000 Registration Date/Time: 2022-01-21 06:28:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 2 of 3) E. Additional Lighting Controls This section does not apply to this project. F. Blank Electrical Boxes This section does not apply to this project. G. Address Signs This section does not apply to this project. H. Single Family Outdoor Lighting This section does not apply to this project. Registration Number: 422-P010008074A-000-001-L01014A-0000 Registration Date/Time: 2022-01-21 06:28:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-LTG-01-E Lighting Single Family Dwellings (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: D cut/1. ' L ,a..i Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-L01014A-0000 Registration Date/Time: 2022-01-21 06:28:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 10) Project Name: Pepe Builds Chihuahua Enforcement Agency: La Quinta, City of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. General Information 01 Dwelling Unit Name Single Family Dwelling 02 Climate Zone 15 03 Dwelling Unit Total Conditioned Floor Area (ft2) 2112 04 Number of Space Conditioning Systems in this dwelling unit. 1 05 Certificate of Compliance Type Performance (CF1R-PRF) 06 Method Used to Calculate HVAC Loads ACCA Manual J 07 Calculated Dwelling Unit Sensible Cooling Load (Btu/h) 96000 08 Calculated Dwelling Unit Heating Load (Btu/h) 96000 09 Dwelling Unit Number of Bedrooms 3 MCH-01a - Space Conditioning Systems Ducts and Fans - For use with Performance Certificate of Compliance Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 10) B. Design Space Conditioning (SC) System Component Specifications from CF1R This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project. 01 02 03 04 05 06 07 08 09 10 11 12 Zone Name SC System Identification or Name SC System Type Heating System Type Cooling System Type SC Fan Type Distribution System Type Required Thermostat Type Low Leakage Air -Handling Unit (LLAHU) Status Bypass Duct Status Cooling Zoning Type Cooling System Compressor Speed This field or section is not applicable Whole Housel Heating and cooling system other Central gas furnace Central split AC PSC Permanent Split Capacitor Unconditione d attic Setback Yes credit is taken No Bypass Duct Not Zonal Single Speed Notes: C. Design Space Conditioning (SC) System Compliance Requirements from CF1R This table reports the space conditioning system features that were specified on the registered CF1R-PRF compliance document for this project. 01 02 03 04 05 06 07 08 09 10 SC System Identification or Name Heating Efficiency Type Minimum Heating Efficiency Value Heat Pump Heating Capacity at 47°F Heat Pump Heating Capacity at 17°F Minimum Cooling Efficiency SEER Minimum Cooling Efficiency EER Minimum Cooling System Airflow Rate (CFM/ton) Maximum Fan Efficacy (W/CFM) Minimum Duct R-Value Whole Housel Annual Fuel Utilization Efficiency (AFUE) 80 This field or section is not applicable This field or section is not applicable 16 13 350 0.58 R-8 Notes: Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 10) D. Installed Space Conditioning (SC) System Component Information 01 02 03 04 05 06 07 08 09 10 11 SC System Identification or Name SC System Location or Area Served Conditioned Floor Area Served by the System (ft2) Heating System Type Cooling System Type SC Fan Type Distribution System Type SC System Thermostat Type Cooling Zoning Type Cooling System Compressor Speed Type Central Fan Integrated (CFI) Ventilation System Status Whole Housel bedrooms 2112 Central gas furnace Central split AC PSC Permanent Split Capacitor Unconditioned attic Setback Not Zonal Single Speed Not a CFI system Notes: E. Installed Heating System Equipment Information (not heat pumps) 01 02 03 04 05 06 07 08 SC System Identification or Name SC System Location or Area Served Heating Efficiency Type Heating Efficiency Value Heating Unit Manufacturer Heating Unit Model Number Heating Unit Serial Number Rated Heating Capacity, Output (Btu/h) Whole Housel bedrooms Annual Fuel Utilization Efficiency (AFUE) 96 TRANE TEM6A03611315BA 21183M4B63 36000 Notes: Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 4 of 10) F. Installed Cooling System Outdoor Condensing Unit or Package Unit Equipment Information (not heat pumps) 01 02 03 04 05 06 07 08 09 SC System Identificatio n or Name SC System Location or Area Served Cooling Efficiency SEER Cooling Efficiency EER Condenser or Package Unit Manufacturer Condenser or Package Unit Model Number Condenser or Package Unit Serial Number System Rated Cooling Capacity at Design Conditions (Btu/h) Condenser Rated Nominal Capacity (ton) Whole Housel bedrooms 16 13 TRANE 4TWR6036H1000 2020170W4F 36000 3 Notes: G. Installed Split System Indoor Coil or Fan Coil Unit Equipment Information (applicable to DX or hydronic heating/cooling coils or fan coil units) Systems with more than one indoor coil or fan coil unit (e.g. multi -split systems) shall provide information for each of the system indoor coils or fan coil units. 01 02 03 04 05 SC System Identification or Name SC System Location or Area Served Indoor Coil or Fan Coil Unit Manufacturer Indoor Coil or Fan Coil Unit Model Number Indoor Coil or Fan Coil Unit Serial Number Whole Housel bedrooms NA NA NA Notes: H. Installed Heat Pump System - Split System Condensing Unit or Package Unit Equipment Information This section does not apply to this project. Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 10) I. Installed Heat Pump System -Efficiency and Performance Compliance Information This section does not apply to this project. J. Installed Duct System Information 01 02 03 04 05 06 07 08 09 10 11 12 SC System Identification or Name SC System Location or Area Served Supply Duct Location Supply Duct R-Value Return Duct Location Return Duct R-Value Exemption from Min R-Value for Ducts In Conditioned Space Method of compliance with duct and filter grille sizing Req's in 150.0(m)13 Exemption From Duct Leakage Requirement s Bypass Duct Status Number of Air Filter Devices on System Can RA3.3 Airflow Protocols be used to test this System? Whole Housel bedrooms Unconditio ned attic R-8 Unconditio ned attic R-8 Not applicable HERS verified fan efficacy (W/cfm) and airflow rate (cfm/ton) None No Bypass Duct 1 Yes Notes: K. Installed Air Filter Device Information Mandatory requirements for air filter devices are specified Section 150.0(m)12. 01 02 03 04 05 06 07 SC System Identification or Name SC System Location or Area Served Air Filter Device Identification or Name Air Filter Device Type Air Filter Device Location Determined Design Airflow Rate for Air Filter Device (cfm) Determined Design Allowable Pressure Drop for Air Filter Device (inch W.C.) Whole Housel bedrooms 1 Filter Grille FAU 1200 .25 Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 10) K. Installed Air Filter Device Information Mandatory requirements for air filter devices are specified Section 150.0(m)12. 01 02 03 04 05 06 07 SC System Identification or Name SC System Location or Area Served Air Filter Device Identification or Name Air Filter Device Type Air Filter Device Location Determined Design Airflow Rate for Air Filter Device (cfm) Determined Design Allowable Pressure Drop for Air Filter Device (inch W.C.) Notes: L. Air Filter Device Requirements 01 The system shall be designed to ensure that all recirculated air and all outdoor air supplied to the occupiable space is filtered before passing through the system's thermal conditioning components. 02 The system shall be designed to accommodate the clean -filter pressure drop imposed by the system air filter device(s). The design airflow rate and maximum allowable clean -filter pressure drop at the design airflow rate applicable to each air filter device shall be determined, and all system air filter device locations shall be labeled to disclose the applicable design airflow rate and the maximum allowable clean -filter pressure drop. The labels shall be permanently affixed to the air filter device, readily legible, and visible to a person replacing the air filter media, and the air filter devices shall be provided with air filter media that conforms to these determined or labeled maximum allowable clean -filter pressure drop values as rated using AHRI Standard 680. 03 All system air filter devices shall be located and installed in such a manner as to allow access and regular service by the system owner. 04 The system shall be provided with air filter media having a designated efficiency equal to or greater than MERV 6 when tested in accordance with ASHRAE Standard 52.2, or a particle size efficiency rating equal to or greater than 50% in the 3.0 to10 iim range when tested in accordance with AHRI Standard 680. 05 The system shall be provided with air filter media that has been labeled by the manufacturer to disclose the efficiency and pressure drop ratings that conform to the required efficiency and pressure drop requirements for the air filter device. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 10) M. HERS Verification Requirements 01 02 03 04 05 06 07 08 09 10 11 12 SC System Identificati on or Name SC System Location or Area Served MCH-20 Duct Leaka a g Test MCH-21 Duct Location Verification MCH-22 AHU Fan Efficacy (W/cfm) MCH-23 AHU Airflow Rate (cfm/ton) MCH-25 Refrigerant Charge g MCH-26 Rated SC System Equipment Verification MCH-27 IAQ Mechanical Ventilation MCH-28 Return Duct Design Table 150.0-B or C MCH-29 Supply Duct Surface Area R-Value Buried Ducts MCH30 Ventilation Cooling Credit Whole Housel bedrooms Yes No Yes Yes Yes Yes Yes No No No Notes: Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 8 of 10) N. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)1 and 2). 04 Furnace Temperature Rise: Central forced -air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet -to -outlet temperature rise specification. See Section 150.0(h)4. 05 Standby Losses and Pilot Lights: Fan -type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Liquid Line Filter Drier: If applicable, a liquid line filter drier shall be installed according to the manufacturer's specifications. Section 150.0(h)3B 10 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 9 of 10) N. Space Conditioning Systems, Ducts and Fans -Mandatory Requirements and Additional Measures Note. Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. 11 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)1. 12 Connections and Closures: All installed air -distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 13 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 14 The thermostat shall be installed in accordance with the manufacturers published installation specifications 15 First stage of heating shall be assigned to heat pump heating. 16 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 10 of 10) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: "Term/ 13cw, Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: t cut/1, i Leath Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M01007A-0000 Registration Date/Time: 2022-01-21 06:25:24 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 1 of 7) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Title 24, Part 6, Section 150.0(o) Ventilation for Indoor Air Quality. All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Equation and table numbering on this form corresponds to the numbering for that information in the published ANSI/SHRAE Standard 62.2-2010. A. Dwelling Mechanical Ventilation - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single Family 03 Project scope Newly constructed building 04 Total Conditioned Floor Area of Dwelling Unit (For addition projects the conditioned floor area equals existing area plus addition area. ) 2112 05 Number of bedrooms in dwelling unit (For addition projects the number of bedrooms equals the existing bedrooms plus addition bedrooms) 3 06 Ventilation Operation Schedule Continuous 07 Whole -Building Ventilation Rate Calculation Method Fan Ventilation Rate Method (4.1.1) 08 Whole Building Ventilation System Type Standalone - Exhaust 09 IAQ Fan Location Note: Non -dwelling units do not meet the definition for a dwelling unit as defined in Section 100.1(b). Non -dwelling units are not designed to provide independent living facilities and do not provide permanent provisions for living, sleeping, eating, cooking and sanitation. MCH-27a - Continuous Ventilation Airflow - Fan Ventilation Rate Method B. Whole -Building Continuous Ventilation - Fan Ventilation Rate Method A mechanical supply system, exhaust system, or combination thereof shall provide whole -building ventilation with outdoor air each hour at no less than the rate in equation 4.1a. 01 Required Continuous Whole -Building Ventilation Rate (Qfan) 51.12 02 Installed Continuous Whole -Building Ventilation Rate 75 Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 2 of 7) C. Compliance Statement 01 Building passes continuous whole -building ventilation rate test Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 3 of 7) D. Local Mechanical Exhaust System - Fan selection and duct design criteria for compliance Local mechanical exhaust fans shall be installed in each kitchen and bathroom. Delivered local ventilation rates: • All local ventilation rates have been measured using a flow hood, flow grid, or other airflow measuring device and meet the requirements of 62.2 Tables 5.1 or 5.2. OR • The airflow rating at a pressure of 0.25 in. w.c. of a certified fan is assumed because the local ventilation system duct sizing meets the prescriptive requirements of 62.2 Table 5.3, or manufacturer's design criteria. Table 5.1 Intermittent Local Ventilation Exhaust Airflow Rates Application Airflow Notes Kitchen 100 cfm Vented range hood (including appliance -range hood combinations) required if exhaust fan flow is less than 5 ACH. Bathroom 50 cfm Table 5.2 Continuous Local Ventilation Exhaust Airflow Rates Application Airflow Notes Kitchen 5 ACH Based on Kitchen volume. Bathroom 20 cfm Table 5.3 Prescriptive Duct Sizing Requirements Duct Type Flex Duct Smooth Duct Fan Rating cfm @ 0.25 in. w.g. 50 80 100 125 50 80 100 125 Maximum Allowable Duct Length (ft) Diameter, (in) Flex Duct Smooth Duct 3 X X X X 5 X X X 4 70 3 X X 105 35 5 X 5 NL 70 35 20 NL 135 85 55 6 NL NL 125 95 NL NL NL 145 7andabove NL NL NL NL NL NL NL NL This table assumes no elbows. Deduct 15 ft of allowable duct length for each turn, elbow, or fitting. Interpolation and extrapolation in 62.2 Table 5.3 is not allowed. For airflow values not listed, use the next higher value. This table is not applicable for airflow > 125 cfm. NL = no limit on duct length of this size. X = not allowed, any length of duct of this size with assumed turns, elbows, fittings will exceed the rated pressure drop. Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 4 of 7) E. Other Requirements The items listed below (6.1 through 6.8) correspond to the information given in ASHRAE 62.2 Section 6 "Other Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.5) for information describing these "Other Requirements". The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable. 01 6.1 Transfer Air. Measures shall be taken to minimize air movement across envelope components to occupiable spaces from garages, unconditioned crawl spaces, and unconditioned attics. Supply and balanced ventilation systems shall be designed and constructed to provide ventilation air directly from the outdoors. 02 6.2 Instructions and Labeling. Information on the ventilation design and/or ventilation systems installed, instructions on their proper operation to meet the requirements of this standard, and instructions detailing any required maintenance (similar to that provided for HVAC systems) shall be provided to the owner and the occupant of the dwelling unit. Controls shall be labeled as to their function (unless that function is obvious, such as toilet exhaust fan switches). See Chapter 13 of Guideline 24 2 for information on instructions and labeling. 03 6.3 Clothes Dryers. Clothes dryers shall be exhausted directly to the outdoors 04 6.4 Combustion and Solid -Fuel Burning Appliances. Combustion and solid -fuel burning appliances must be provided with adequate combustion and ventilation air and vented in accordance with manufacturer installation instructions, NFPA 54 ANSI 2223.1, National Fuel Gas Code, NFPA 31, Standard for the Installation of Oil -Burning Equipment, or NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid -Fuel Burning Appliances, or other equivalent code acceptable to the building official. Where atmospherically vented combustion appliances or solid -fuel burning appliances are located inside the pressure boundary, the total net exhaust flow of the two largest exhaust fans (not including a summer cooling fan intended to be operated only when windows or other air inlets are open) shall not exceed 15 cfm/100 ft2 (75 Lps/100 m2) of occupiable space when in operation at full capacity. If the designed total net flow exceeds this limit, the net exhaust flow must be reduced by reducing the exhaust flow or providing compensating outdoor airflow. Atmospherically vented combustion appliances do not include direct -vent appliances. 05 6.5 Garages. When an occupiable space adjoins a garage, the design must prevent migration of contaminants to the adjoining occupiable space. Air seal the walls, ceilings, and floors that separate garages from occupiable space. To be considered air sealed, all joints, seams, penetrations, openings between door assemblies and their respective jambs and framing, and other sources of air leakage through wall and ceiling assemblies separating the garage from the residence and its attic area shall be caulked, gasketed, weather stripped, wrapped, or otherwise sealed to limit air movement. Doors between garages and occupiable spaces shall be gasketed or made substantially airtight with weather stripping. 06 6.6 Ventilation Opening Area. Spaces shall have ventilation openings as listed below. Such openings shall meet the requirements of Section 6.8 07 6.7 Minimum Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 ft (3 m) in length and through a thermal conditioning component, except evaporative coolers, shall be provided with a filter having a designated minimum efficiency of MERV 6, or better, when tested in accordance with ANSI ASHRAE Standard 52.2, Method of Testing General Ventilation Air -Cleaning Devices for Removal Efficiency by Particle Size, or a minimum Particle Size Efficiency of 50 percent in the 3.0-10 µm range in accordance with AHRI Standard 680, Performance Rating of Residential Air Filter Equipment. The system shall be designed such that all recirculated and mechanically supplied outdoor air is filtered before passing through the thermal conditioning components. The filter shall be located and installed in such a manner as to facilitate access and regular service by the owner. Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 5 of 7) E. Other Requirements The items listed below (6.1 through 6.8) correspond to the information given in ASHRAE 62.2 Section 6 "Other Requirements". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.5) for information describing these "Other Requirements". The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 6.1 through 6.9 if applicable. 08 6.8 Air Inlets. Air inlets that are part of the ventilation design shall be located a minimum of 10 ft (3 m) from known sources of contamination such as a stack, vent, exhaust hood, or vehicle exhaust. The intake shall be placed so that entering air is not obstructed by snow, plantings, or other material. Forced air inlets shall be provided with rodent insect screens (mesh not larger than 1/2 inch). 09 6.9 Carbon Monoxide Detectors. A carbon monoxide alarm shall be installed in each dwelling unit in accordance with NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 14, and shall be consistent with requirements of applicable laws, codes, and standards. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. F. Air Moving Equipment The items listed below (7.1 through 7.3) correspond to the information given in ASHRAE 62.2 Section 7Air-Moving Equipment. Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.6) for information describing these requirements in more detail. The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 7.1 through 7.3 if applicable. 01 7.1 Selection and Installation. Ventilation devices and equipment shall be tested and listed in accordance with specific standards. Installations of systems or equipment shall be carried out in accordance with manufacturers' design requirements and installation instructions. 02 7.2 Sound Ratings for Fans. Ventilation fans shall be rated for sound at no less than the minimum airflow rate required by this standard, as noted below. These sound ratings shall be at a minimum of 0.1 in. w.c. (25 Pa) static pressure. 7.2.1 Whole Building or Continuous Ventilation Fans. These fans shall be rated for sound at a maximum of 1.0 sone. 7.2.2 Intermittent Local Exhaust Fans. Fans used to comply with Section 5.2 shall be rated for sound at a maximum of 3 sone, unless their maximum rated airflow exceeds 400 cfm (200 L/s). (Some exceptions may apply.) 03 7.3 Multibranch Exhaust Ducting. If more than one of the exhaust fans in a dwelling unit shares a common exhaust duct, each fan shall be equipped with a back draft damper to prevent the recirculation of exhaust air from one room to another through the exhaust ducting system. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 6 of 7) G. Multifamily Buildings -Other Requirements The items listed below correspond to the information given in ASHRAE 62.2 Section 8 "Multifamily Buildings". Refer also to Chapter 4.6 of the Residential Compliance Manual (Section 4.6.5) for information describing these requirements in more detail. The signature of the Responsible Person in the declaration statement below certifies that the building complies with these requirements specified in ASHRAE 62.2 Section 8, if applicable. 8.2 Whole -Building Mechanical Ventilation. For multifamily buildings, the term "building" in Section 4 refers to a single dwelling unit. 8.4.1 Transfer Air. Measures shall be taken to minimize air movement across envelope components separating dwelling units, including sealing penetrations in the common walls, ceilings, and floors of each unit and by sealing vertical chases adjacent to the units. All doors between dwelling units and common hallways shall be gasketed or made substantially airtight. 8.4.1.1 Compliance. One method of demonstrating compliance with Section 8.4.1 shall be to verify a leakage rate below a maximum of 0.2 cfm/ ft2 (100 Lis per 100 m2) of the dwelling unit envelope area (i.e., the sum of the area of the walls 01 between dwelling units, exterior walls, ceiling and floor) at a test pressure of 50 Pa by a blower door test. The test shall be conducted with the dwelling unit as if it were exposed to outdoor air on all sides, top, and bottom by opening doors and windows of adjacent dwelling units. 8.5.1 Exhaust Ducts. Exhaust fans in separate dwelling units shall not share a common exhaust duct. Exhaust inlets from more than one dwelling unit may be served by a single exhaust fan downstream of all the exhaust inlets if the fan is designated and intended to run continuously or if each inlet is equipped with a back -draft damper to prevent cross -contamination when the fan is not running. 8.5.2 Supply Ducts. Supply outlets to more than one dwelling unit may be served by a single fan upstream of all the supply outlets if the fan is designed and intended to run continuously or if each supply outlet is equipped with a back -draft damper to prevent cross -contamination when the fan is not running. The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 7 of 7) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M27008A-0000 Registration Date/Time: 2022-01-21 06:25:40 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:39:59 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. System Information 01 Space Conditioning System Identification or Name Whole Housel 02 Space Conditioning System Location or Area Served bedrooms 03 Building Type from CF-1R Single family 04 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 05 Verified Low Leakage Air Handling Unit (VLLAHU) Credit from CF1R? Yes credit is taken 06 Duct System Compliance Category New MCH-20c - Low Leakage Air -Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Condenser Nominal Cooling Capacity (ton) 3 02 Heating Capacity (kBtu/h) 36 03 Conditioned Floor Area served by this HVAC system (ft2) 2112 04 Duct Leakage Test Conditions Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.06 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Cooling system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct Leakage (cfm) 72 10 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 66 11 Air Handling Unit Manufacturer Name TRANE Registration Number: 422-P010008074A-000-001-M20009A-0000 Registration Date/Time: 2022-01-21 06:25:59 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:00 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) B. Duct Leakage Diagnostic Test 12 Air Handling Unit Model Number TEM6A03611315BA 13 Compliance Statement System passes leakage test C. Additional Requirements for Compliance 01 The Low Leakage Air -handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air -Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment cert/Ilahu/low leakage air handling units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-M20009A-0000 Registration Date/Time: 2022-01-21 06:25:59 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:00 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M20009A-0000 Registration Date/Time: 2022-01-21 06:25:59 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:00 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Ducted Cooling System Information 01 System Identification or Name Whole Housel 02 System Location or Area Served bedrooms 03 System Installation Type New 04 Nominal Cooling Capacity (tons) of Condenser 3 05 Condenser Speed Type Single Speed 06 Cooling System Zonal Control Type Not Zonal 07 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 08 System Bypass Duct Status No Bypass Duct 09 Date of System Airflow Rate Measurement 2022-01-20 10 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus alnor 03 Model number of Airflow Measurement Apparatus 371 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas /index.html Registration Number: 422-P010008074A-000-001-M23010A-0000 Registration Date/Time: 2022-01-21 06:26:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:01 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 3) MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non -Zoned Systems or Zoned Multi -Speed Compressor D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton) 350 02 Required Minimum System Airflow Target (cfm) 1050 03 Actual System Airflow Rate Measurement (cfm) 1074 04 Compliance Statement: System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Installation. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Installation was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm that bypass ducts that deliver conditioned supply air directly to the space conditioning system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi -speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-M23010A-0000 Registration Date/Time: 2022-01-21 06:26:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:01 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M23010A-0000 Registration Date/Time: 2022-01-21 06:26:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:01 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Ducted Cooling System Information 01 System Identification or Name Whole Housel 02 System Location or Area Served bedrooms 03 System Installation Type New 04 Nominal Cooling Capacity (tons) of Condenser 3 05 Condenser Speed Type Single Speed 06 Cooling System Zonal Control Type Not Zonal 07 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 08 System Bypass Duct Status No Bypass Duct 09 Date of System Airflow Rate Measurement 2022-01-20 10 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used. Portable watt meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non -Zoned Systems or Zoned Multi -Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 621 02 Actual Tested Airflow from MCH-23 (cfm) 1074 03 Required Fan Efficacy (watts/cfm) 0.58 04 Actual Fan Efficacy (watts/cfm) 0.58 05 Compliance Statement: System fan efficacy complies Registration Number: 422-P010008074A-000-001-M22011A-0000 Registration Date/Time: 2022-01-21 06:26:41 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:01 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi -speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-M22011A-0000 Registration Date/Time: 2022-01-21 06:26:41 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:01 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M22011A-0000 Registration Date/Time: 2022-01-21 06:26:41 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:01 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 1 of 4) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. System Information Each system requiring refrigerant charge verification will be documented on a separate certificate. 01 System Identification or Name Whole Housel 02 System Location or Area Served bedrooms 03 Condenser (or package unit) Make or Brand TRANE 04 Condenser (or package unit) Model Number 4TWR6036H1000 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) Serial Number 2020170W4F 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable) This field or section is not applicable 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer). This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes, this is a ducted system and one of the system airflow rate measurement procedures in RA3.3 or RA3.3.3 can be used to verify system airflow rate requirements. 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55°F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2022-01-20 15 Refrigerant charge verification method used. Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling Registration Number: 422-P010008074A-000-001-M25012A-0000 Registration Date/Time: 2022-01-21 06:28:10 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 2 of 4) MCH-25b - Refrigerant Charge Verification - Subcooling Method B. Metering Device Verification Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2022-01-20 02 Date of Digital Thermocouple Calibration 2022-01-20 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 Minimum Required System Airflow Rate (cfm) 1050 02 System Airflow Rate Verification Status System complies with minimum airflow rate requirements F. Data Collection and Calculations Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2. 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure (°F) 70 02 Measured Condenser Air Entering Dry -Bulb Temperature (Tcondenser, db) 74 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method Registration Number: 422-P010008074A-000-001-M25012A-0000 Registration Date/Time: 2022-01-21 06:28:10 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:02 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 3 of 4) F. Data Collection and Calculations Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2. 04 Measured Liquid Line Temperature (-liquid) (°F) 102.3 05 Measured Liquid Line Pressure (Puquid) (psig) 245.2 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 (°F) 116.6 07 Measured Subcooling (Line F06 - Lilne F04 (°F) 14.3 08 Target Subcooling from Manufacturer (°F) 12 09 Compliance Statement: System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) (°F) 70.2 02 Measured Suction Line Pressure (Psuction) (psig) 114.2 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 (°F) 59.6 04 Measured Superheat (Line G01- Line G03) (°F) 10.6 05 Measured Superheat (Line G04) is between 4°F and 25°F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement Metering device verification passes MCH-25d - Refrigeration Charge Verification - Fault Indicator Display (FID) H. Fault Indicator Display This section does not apply to this project. I. Fault Indicator Display Additional Requirements This section does not apply to this project. Registration Number: 422-P010008074A-000-001-M25012A-0000 Registration Date/Time: 2022-01-21 06:28:10 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-25-H Refrigerant Charge Verification (Page 4 of 4) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M25012A-0000 Registration Date/Time: 2022-01-21 06:28:10 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 System Name or Identification/Tag Whole Housel 02 System Location or Area Served bedrooms 03 Status: SEER and EER performance compliance credit check Both SEER and EER HERS Verification is required 04 Directory used to certify product performance AHRI 05 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 1224588858 06 Does the directory used to certify product performance require a specific air handler/furnace make and model? No 07 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 08 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Verification The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. Data from Nameplate of Installed system component Data from the Directory used to certify product performance for the rated system component Outdoor Condenser or Package Unit - Installed Manufacturer Name 01 TRANE 02 TRANE Outdoor Condenser or Package Unit - Installed Model Number 03 4TWR6036H1000 04 4TWR6036H1000 Inside Coil - Installed Manufacturer Name 05 NA 06 NA Inside Coil - Installed Model Number 07 NA 08 NA Air Handler/Furnace - Installed Manufacturer Name 09 TRANE 10 TRANE Registration Number: 422-P010008074A-000-001-M26013A-0000 Registration Date/Time: 2022-01-21 06:28:42 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:02 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 3) B. Rated Space Conditioning System Equipment Verification The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. Air Handler/Furnace - Installed Model Number 11 TEM6A03611315BA 12 TEM6A03611315BA C. Verified Cooling System SEER 01 Required minimum SEER 16 02 Installed SEER 16 03 Compliance Statement: System passes SEER verification Signature by responsible party below certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. D. Verified Cooling System EER 01 Required minimum EER 13 02 Installed EER 13 03 Compliance Statement: System passes EER verification Signature by responsible party below certifies that the installed cooling equipment meets or exceeds the required value listed on the CF1R. E. Verified Cooling System Air Handler/Furnace This section does not apply to this project. F. Verified Cooling System Time Delay Relay 01 If a Time Delay Relay is required by the directory used to certify product performance, the responsible party certifies by signing below that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. G. Verified Cooling System TXV 01 If a TXV is required by the directory used to certify product performance, the responsible party certifies by signing below that the TXV is properly installed and has been visually verified, including proper placement of sensing bulb Registration Number: 422-P010008074A-000-001-M26013A-0000 Registration Date/Time: 2022-01-21 06:28:42 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7-(1-viu13cx,� , Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I understand that a HERS rater will check the installation to verify compliance and if such checking determines the installation fails to comply, I am required to offer any necessary corrective action at no charge to the building owner. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Dcv'LGli LPX4).J Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Third Party Quality Control Program (TPQCP) Status: Name of TPQCP (if applicable): Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M26013A-0000 Registration Date/Time: 2022-01-21 06:28:42 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:02 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 1 of 5) Project Name: Pepe Builds Chihuahua Enforcement Agency: La Quinta, City of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. General Information 01 Dwelling Unit Name Single Family Dwelling B. Design Dwelling Unit Water Heating Systems Information This table reports the water heating system features that were specified on the registered CF1R compliance document for this project. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Water Heating System ID or Name Water Heating System Type Water -Heater Type # of Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss (%) Exterior Insul. R-Value Central DHW System Distribution Type Dwelling Unit DHW System Distribution Type yPe DHW Sys 1 Domestic Hot Water (DHW) Small Storage 1 50.00 Natural Gas Btu/Hr 75000.00 Energy Factor (EF) 0.65 This field or section is not applicable This field or section is not applicable This field or section is not applicable Parallel Piping C. Installed Dwelling Unit Water Heating Systems Information 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Water Heating System ID or Name Water Heating System Type Water -Heater Type # of Water Heaters in System Water Heater Storage Volume (gal) Fuel Type Rated Input Type Rated Input Value Heating Efficiency Type Heating Efficiency Value Standby Loss (%) Exterior Insul. R-Value Central DHW System Distribution Type Dwelling Unit DHW System Distribution ype Type DHW Sys 1 Domestic Hot Water (DHW) Small Storage 1 50 Natural Gas Btu/Hr 75000 Energy Factor (EF) 0.65 This field or section is not applicable This field or section is not applicable This field or section is not applicable Parallel Piping Registration Number: 422-P010008074A-000-001-B02015A-0000 Registration Date/Time: 2022-01-21 06:29:10 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:03 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 2 of 5) D. Installed Water Heater Manufacturer Information 01 02 03 Water Heating System ID or Name Manufacturer Model Number DHW Sys 1 AO SMITH 142556545 E. Mandatory Measures For All Domestic Hot Water Distribution Systems 01 Equipment shall meet the applicable requirements of the Appliance Efficiency Regulations (Section 110.3(b)1). 02 Unfired Storage Tanks are insulated with an external R-12 or combination of R-16 internal and external Insulation. (Section 110.3(c)4). 03 The following pipes are insulated, to the thicknesses required by Table 120.3A, except for those sections of pipe that are subject to one of the exceptions below: (RA4.4.1) • The first 5 feet (1.5 meters) of hot and cold water pipes from the storage tank. • All piping with a nominal diameter of 3/4 inch (19 millimeter) or larger. • All piping associated with a domestic hot water recirculation system regardless of the pipe diameter, except when cold water return is used in a demand system. • Piping from the heating source to storage tank or between tanks. • Piping buried below grade. • All hot water pipes from the heating source to the kitchen fixtures. The following sections of pipe do not have to be insulated: (RA4.4.1) • Piping installed in interior or exterior walls that is surrounded on all sides by at least 1 inch of insulation. • Piping installed in attics with a minimum of 4 inches (10 cm) of attic insulation on top • Piping that penetrates framing members shall not be required to have pipe insulation for the distance of the framing penetration. Metal piping that penetrates metal framing shall use grommets, plugs, wrapping or other insulating material to assure that no contact is made with the metal framing. Insulation shall butt securely against all framing members. 04 Piping buried below grade must be installed in a water proof and non -crushable casing or sleeve that allows for installation, removal, and replacement of the enclosed pipe and insulation. (Section 150.0(j)) 05 All elbows and tees shall be fully insulated. (RA4.4.1) 06 Where insulation is required, no piping shall be visible due to insulation voids, and all insulation shall fit tightly to the pipe. (RA4.4.1) Registration Number: 422-P010008074A-000-001-B02015A-0000 Registration Date/Time: 2022-01-21 06:29:10 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:03 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 3 of 5) E. Mandatory Measures For All Domestic Hot Water Distribution Systems 07 For Gas or Propane Water Heaters: Ensure the following are installed (Section 150.0(n)) 1. A 120V electrical receptacle is within 3 feet from the water heater and accessible with no obstructions 2. A Category III or IV vent, or a Type B vent with straight pipe between outside and water heater 3. A condensate drain no more than 2 inches higher than the base on water heater for natural draining 4. A gas supply line with capacity of at least 200,000 Btu/Hr The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. F. Standard Distribution System Requirements (trunk and branch systems only) This section does not apply to this project. G. Pipe Insulation Credit Requirements (for trunk and branch Hot Water system) This section does not apply to this project. H. Parallel Piping Requirements 01 Each central manifold has 15 feet or less of pipe between manifold and water heater (RA 4.4.15) 02 For manifolds that include valves, the manifold must be readily accessible in accordance with the plumbing code. (RA 4.4.4) 03 Hot water distribution system piping from the manifold to the fixtures and appliances must take the most direct path. For instance, piping from a second story manifold cannot supply the first floor. (RA 4.4.4) 04 The hot water distribution piping must be separated by at least 2 inches from any other hot water supply piping, and at least 6 inches from any cold water supply piping. Alternatively, the hot water supply piping must be insulated to the thicknesses shown in TABLE 120.3-A. (RA 4.4.4) The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 422-P010008074A-000-001-B02015A-0000 Registration Date/Time: 2022-01-21 06:29:10 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:03 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 4 of 5) I. Point of Use Requirements This section does not apply to this project. J. Recirculation Non -Demand Controls Requirements This section does not apply to this project. K. Demand Recirculation Manual Control Requirements This section does not apply to this project. L. Demand Recirculation Sensor Control Requirements This section does not apply to this project. Registration Number: 422-P010008074A-000-001-B02015A-0000 Registration Date/Time: 2022-01-21 06:29:10 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:03 Schema Version: rev 20180426 CERTIFICATE OF INSTALLATION CF2R-PLB-02-E Single Dwelling Unit Hot Water System Distribution (Page 5 of 5) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-VV►i 13a.drld w Company: MLC Building Performance Signature Date: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement, or b) I am an authorized representative of the responsible person and attest to the declarations in this statement on the responsible person's behalf. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and specifications approved by the enforcement agency. 4. I will ensure that a registered copy of this Certificate of Installation shall be posted or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: David Leal Responsible Builder/Installer Signature: Douvilth (poth Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Compressor Air Conditioning and Heating Position With Company (Title): Contractor/Installer Address: 47892 Pheonix Street CSLB License: 957516 City/State/Zip: Indio CA 92201 Phone: (760) 610-3118 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-B02015A-0000 Registration Date/Time: 2022-01-21 06:29:10 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:03 Schema Version: rev 20180426 CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 1 of 6) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Air Infiltration And Insulation Installation (Qii) - Framing Stage 01 The requirements below cover the required air sealing and installation of insulation that must occur in the framing stage. 02 An air barrier is required in all thermal envelope assemblies to limit air movement between unconditioned/outside spaces and conditioned/inside spaces and must meet one of the following: 1. Using individual materials that have an air permeance not exceeding 0.004 cfm/ft2 under pressure differential of 0.3 in w.g. (1.57 psf) (0.02 L/s.m2 at 75 pa) when tested in accordance with ASTM E2178; or • A list of example materials meeting the air permenace testing performance levels of 1 above is available in RA3.5.2 2 Using assemblies of materials and components that have an average air leakage not to exceed 0.04 cfm/ft2 under a pressure differential of 0.3 in w.g. (1.57 psf) (0.2 L/s.m2 at 75 pa) when tested in accordance with ASTM E2357, ASTM E1677, ASTM E1680 or ASTM E283, or 3. Testing the complete building and demonstrating that the air leakage rate of the building envelope does not exceed 0.4 cfm/ft2 at a pressure differential of 0.3 in w.g. (1.57 psf) (2.0 L/m2 at 75 pa) in accordance with ASTM E779 or an equivalent approved method. 03 Air Barrier Material Installed 04 Verification Status Pass - all applicable requirements are met 05 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. B. Raised Floor 01 All gaps in the raised floor are sealed. 02 All chases sealed at floor level using a hard cover and the hard covers are sealed. 03 All Plumbing and electrical wires that penetrate the floor are sealed. 04 Subfloor sheathing is glued or sealed at all exterior panel edges, to create a continuous air tight subfloor. 05 Verification Status Pass - all applicable requirements are met 06 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: 422-P010008074A-000-001-E21004A-E21A Registration Date/Time: 2022-01-21 06:30:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 2 of 6) C. Walls/Knee Walls 01 All penetrations through the exterior wall air barrier are sealed to provide an air -tight envelope to unconditioned spaces such as the outdoors, attic, garage and crawl space. 02 Exterior wall air barrier is sealed to the top plate and bottom plate in each stud bay. 03 All electrical boxes including knockouts that penetrate the air barrier to unconditioned space are sealed. 04 All openings in top and bottom plate, including all interior and exterior walls, to unconditioned space are sealed. Such as holes drilled for electrical and plumbing. 05 Exterior bottom plates (all stories) are sealed to the floor using the appropriate sealing method. 06 All gaps around windows and doors are sealed. Proper sealant used was specified by window manufacturer. 07 Rim Joists all gaps and openings fully sealed. 08 Fan exhaust ducts that run between conditioned floors to exterior walls have a damper at the exterior wall. 09 Metal tie downs are insulated between exterior framing and tie down. 10 Insulation is installed in hard to access wall stud cavities, such as corner channels, wall intersections are insulated to the proper R-value prior to exterior sheathing, or the exterior stucco lath. 11 Insulation is installed behind tub, when located against exterior walls. shower, fireplace enclosures, and exterior stairwells to the R-value listed on the CF1R Insulation is required to be installed before tub, shower, and fireplace are installed. 12 A solid air barrier is installed on the interior wall from floor to ceiling tub, shower, and fireplace enclosures are installed in exterior walls. Insulation in contact on all six sides of air barrier on exterior walls. 13 All single -member window and door headers shall be insulated to a minimum of R-3 for a 2x4 framing, or equivalent width, and a minimum of R-5 for all other assemblies. Insulation is to be placed between the interior face of the header and inside surface of the interior wall finish. If continuous exterior rigid insulation is used an insulated header is not required. No header insulation is required for single -member headers that are the same width as the wall, so long as the entire wall has at least R-2 insulation. 14 Knee walls have solid and sealed blocking at the bottom, top, left side and right side of the knee wall. 15 Verification Status Pass - all applicable requirements are met 16 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Ceiling/Attic 01 For vented attics much of the ceiling air barrier is verified after the ceiling drywall is installed using the ENV-22. 02 For non -vented attics ensure all penetrations through the roof deck and gable ends are sealed and air tight. Registration Number: 422-P010008074A-000-001-E21004A-E21A Registration Date/Time: 2022-01-21 06:30:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:06 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 3 of 6) D. Ceiling/Attic 03 All eave vents are covered with a rigid ventilation baffle that maintains the Net free -ventilation area. 04 All dropped ceilings and soffits are covered with hard covers and sealed to framing. 05 All chases are covered with hard covers and sealed to framing. 06 HVAC ducts that travel down a chase the chase is sealed at the ceiling level. 07 Chimney and Flue require sheet metal flashing. The flashing shall be sealed to the chimney or flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 08 All Eave/soffit baffles are installed to stop air movement around the baffle and into insulation. Net free -ventilation of the eave/soffit shall be maintained. 09 Double walls that open to attic are covered with an air barrier and cover has an air tight seal to the framing. 10 Verification Status Pass - all applicable requirements are met 11 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Conditioned Space Above Or Adjacent To Garage Air Barrier 01 All penetrations in the subfloor above the garage into conditioned space must follow the raised floor air barrier requirements above. 02 Infiltration between the space above the garage and subfloor is prevented by one of the following methods: • Seal all edges of garage ceiling (typically drywall) at the perimeter of the garage to create a continuous air tight surface between the garage and adjacent conditioned envelope. Seal all plumbing, electric and mechanical penetrations between the garage and the adjacent conditioned space. For an open -web truss, airtight blocking is added on four sides of the garage perimeter. Insulation can be placed on the garage ceiling. • Seal band joist above the wall at the garage to conditioned space transition. Seal all subfloor seams and penetrations between the conditioned space and the garage. Insulation must be placed in contact of subfloor below conditioned space. 03 Verification Status Pass - all applicable requirements are met 04 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. F. Walls For Attached Porch, Attic, Double Wall 01 All walls that separate conditioned and unconditioned space includes a continuous air barrier on the interior and exterior wall. Registration Number: 422-P010008074A-000-001-E21004A-E21A Registration Date/Time: 2022-01-21 06:30:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:06 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 4 of 6) F. Walls For Attached Porch, Attic, Double Wall 02 Exterior wall, air barrier required at the intersection of the porch and exterior wall when there is conditioned space on the other side. The exterior wall where the attic attaches to the conditioned space does includes an air barrier. 03 Truss framing blocking is used at the top and bottom of each wall/roof section. 04 Verification Status Pass - all applicable requirements are met 05 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. G. Cantilevered Floor Air Barrier 01 Airtight blocking is installed between joists where the wall rim joist would have been located in the absence of a cantilever. 02 Exterior sheathing is installed to the bottom of the cantilever so that there is a continuous air and weather barrier for the cantilever. The cantilevered joist must be insulated to the same R value as would be required for the subfloor prior to closing. 03 Any gaps, cracks or penetrations in the air barrier of the cantilever are sealed. Can lights in the cantilever are IC and AT rated and properly sealed to sheathing. 04 Verification Status Pass - all applicable requirements are met 05 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. H. Multifamily Air Barrier 01 Multifamily buildings must meet all air sealing requirements for single family buildings listed above. 02 Each dwelling unit must be air sealed to stop air movement from one unit to another. 03 Floor AND Ceiling of each Dwelling Unit: All penetrations through the floor and ceiling of each unit are sealed including, electric and gas utilities, water pipes, drain pipes, fire protection service pipes, communication wiring. 04 Elevator penthouse, mechanical penthouse, stairwell doors, roof access hatch, plumbing stacks sealed to reduce air transfer from attached spaces. 05 Common Walls: Bottom plate between units is sealed to the subfloor. All penetrations in the common walls are sealed including electrical boxes, wiring and plumbing penetrations. Perpendicular Interior walls that open into the common walls are sealed. 06 Vertical Chases for garbage chutes, elevator shafts, and HVAC ducting plumbing must be sealed to the floor and ceiling of each unit to stop air movement up and around the chase due to stack effect. Registration Number: 422-P010008074A-000-001-E21004A-E21A Registration Date/Time: 2022-01-21 06:30:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:06 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 5 of 6) H. Multifamily Air Barrier 07 Vertical Chases such as garbage chutes, elevator shafts, and HVAC ducting plumbing, wiring etc. must be sealed to stop air movement through the chase to the surrounding spaces. 08 Common Hallways - Penetrations between dwelling unit and common hallways are sealed, doors to the dwelling unit are gasketed or made substantially airtight . 09 Verification Status Pass - all applicable requirements are met 10 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. I. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-E21004A-E21A Registration Date/Time: 2022-01-21 06:30:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-21-H Quality Insulation Installation (QII) Air Infiltration Sealing - Framing Stage for Batt, Loose Fill, and SPF (Page 6 of 6) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: 7 oin' BCA, 1/14.44, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN 10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E21004A-E21A Registration Date/Time: 2022-01-21 06:30:22 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 For typical vented attics where the insulation is at the roof deck ceiling air barrier must be verified after the ceiling drywall is installed and before attic insulation is installed. If SPF will be used in the attic this can be considered the air barrier. Soffit and chases must still be covered and chimneys and flues require metal flashing. Buildings with a Non vented attic all air sealing requirements appropriate for the roof must be verified. A. Ceiling Inspection - Vented Attics 01 If there is a continuous air barrier at the ceiling level; All opening into walls, drops, chasses, double walls are sealed. Examples are below. 02 Chimney and Flue require sheet metal flashing. The flashing shall be sealed to the chimney or flue with fire rated caulk. The flashing shall be sealed to the surrounding framing. 03 All penetration through the top plate of interior and exterior walls are sealed. 04 All penetrations shall be sealed to the surrounding drywall or have a secondary air barrier created around the fixture; with the exception of fire sprinklers. 05 All installed recessed light fixtures that penetrate the ceiling to unconditioned space, or where insulation is present, are rated to be Insulation Contact and Air Tight (IC and AT) which allows direct contact with insulation. Housing is sealed to the drywall. 06 Exhaust fan housing is sealed to surrounding drywall and all holes and seams in the housing sealed. 07 All soffits and chases are covered with a hard cover that is sealed to the framing with caulk or foam. 08 Double walls that open to attic are covered and the cover sealed to the framing. 09 Attic Access forms airtight seal from conditioned space to unconditioned space. Vertical attic access requires mechanical compression using screws, or latches. 10 Knee walls require solid and sealed blocking at the bottom, top left side and right side of the knee wall. When the knee wall is placed on top of a subfloor the open cavity below the subfloor and the ceiling below are sealed. 11 HVAC ducts that travel down a chase the chase are sealed at the ceiling level. 12 HVAC boots that penetrate the ceiling are sealed to the surrounding drywall. 13 All top plates of interior and exterior walls sealed to drywall. 14 Attic access must be surrounded with a dam at least the same depth as the insulation to prevent loss of ceiling insulation. 15 There must be a dam placed at the exterior edge of all kneewalls and all edges of insulation to stop air movement through insulation. 16 Verification Status: Pass - all applicable requirements are met Registration Number: 422-P010008074A-000-001-E22005A-E22A Registration Date/Time: 2022-01-21 06:30:16 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:05 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 2 of 3) A. Ceiling Inspection - Vented Attics 17 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. B. Roof Inspection - Non -Vented Attics 01 There is a continuous air barrier at the roof deck and gable ends. 02 Chimney and Flue require sheet metal flashing at the roof deck. The flashing is sealed to the chimney or flue with fire rated caulk. The flashing is sealed to the surrounding framing. 03 All penetrations for plumbing, electrical etc in the roof deck and gable ends are sealed. 04 Verification Status: Pass - all applicable requirements are met 05 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. C. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-E22005A-E22A Registration Date/Time: 2022-01-21 06:30:16 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-22-H Quality Insulation Installation (QII) Air Infiltration Sealing - Ceiling Roof Deck (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E22005A-E22A Registration Date/Time: 2022-01-21 06:30:16 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 1 of 7) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Quality Insulation Installation (QII) Preparation For Insulation 01 Air barrier installation and preparation for insulation was done and verified at framing stage prior to insulation being installed. Where applicable, CF3R-ENV21 and 22 compliance documents have been signed off. 02 All structural framing areas shall be insulated in a manner that resists thermal bridging of the assembly separating conditioned from unconditioned space. Structural bracing, tie -downs, and framing of steel, or specialized framing used to meet structural requirements of the CBC are allowed and must be insulated. These areas shall be called out on the building plans with diagrams and or specific design drawings indicating the R-value of insulation and fastening method to be used. It is recommended that spray foam be used. 03 All insulation was installed to the manufactures insulation installation instructions. 04 Verification Status: Pass - all applicable requirements are met 05 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. B. Quality Of All Installed Insulation 01 Installed insulation R-values is the same or greater than specified on the CF1R. 02 No gaps or voids between the insulation and framing. 03 Gaps between studs shall be filled with insulation. 04 Batt - ensure the ends are cut so there are no gaps. 05 Batt - Insulation is cut around obstructions like electrical boxes and no gaps exist. 06 Batt - insulation is not compressed (no stuffing of the insulation into the cavity. 07 Batt insulation is delaminated around all plumbing and electrical lines in ceilings, walls and floors. 08 An air barrier is installed at all exposed faces of batt, loose fill and SPF insulation. 09 Loose -fill insulation installed to the minimum installed weight per ft2 per the manufacturer labeled R-value specification. 10 SPF insulation shall be spray -applied to fully adhere to structural assembly framing, floor and ceiling joists, and other framing surfaces within the construction cavity. 11 SPF - with multiple layers applied, each foam lift (i.e. spray application) adheres to the substrate and foam interfaces. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 2 of 7) B. Quality Of All Installed Insulation 12 SPF - if values other than R-5.8 per inch for closed -cell SPF (ccSPF) and R-3.6 per inch for open -cell SPF (ocSPF) are used, the ICC Evaluation Service Report (ESR) number (e.g. ESR-xxxx) will be documented in the CF2R-ENV-03. 13 ccSPF in areas where an air barrier is required the foam is at least 2 inches thick. 14 ocSPF depressions in the foam insulation surface is not greater than 1-inch of the required thickness provided these depressions do not exceed 10 percent of the surface area being insulated. 15 ocSPF insulation completely fills cavities of 2x4 inch framing or less. 16 ocSPF cavities greater than 2x4 inch framing are filled to the thickness that meets the required R-value used for compliance. 17 SPF installed as an air barrier is sprayed at a minimum thickness of 5.5 inches for open cell and 2.0 inches for closed cell. 18 The insulation installer provided a CF2R-ENV-03. Labels or specification/data sheets are attached to the CF2R-ENV-03 for each insulating material. The material datasheet for the installed material meets the performance specifications of the required R-Values. Blown in material also includes insulation material bag labels or coverage charts. 19 Verification Status: Pass - all applicable requirements are met 20 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. C. Ceiling/Roof Insulation Quality 01 Insulation extends to the outside edge of the exterior top plates and is flush against any ventilation dams or baffles. 02 Insulation is in direct contact with ceiling so there are no gaps between the ceiling and the insulation. 03 Chimneys and flues (except for zero clearance) require a sheet metal collar around the stack. The collar must be at least as tall as the depth of the insulation. The collar shall be 1 inch from the chimney or flue for double wall vents, and 6 inches from the chimney/flue for single wall vents unless the manufacturer requires otherwise. The collar must be sealed to the ceiling with high temperature sealant to prevent air leakage. The insulation is in contact with the sheet metal collar. 04 Required eave ventilation shall not be obstructed - the net free -ventilation area of the eave vent is maintained 05 Eave vent baffles are installed to prevent air movement under or into the ceiling insulation 06 Recessed downlights are covered with insulation. If they are not covered to the same depth as required by the CF1R for ceiling insulation then a area weighted calculation is required. Recessed downlights are AT and IC rated. 07 SPF insulation shall not be applied directly to recessed lighting fixtures. Recessed downlights where SPF insulation is installed shall: (a) be covered with a minimum of 1.5 inches of mineral fiber insulation, or (b) be enclosed in a box fabricated from 1/4 inch plywood, 18 gauge metal, 3/8 inch hard board or gypboard. Hard board or gypboard does not cause a recessed downlights to meet the zero clearance insulation contact requirements. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page3of7) C. Ceiling/Roof Insulation Quality 08 Walkways and mechanical platforms are insulated to the same R-value as required by the CF1R for ceiling insulation. If not, an area weighted calculation is completed and turned in with this compliance document. 09 Soffits, chasses and drop ceiling areas have a sealed hard cover and the insulation is in direct contact with the hard cover. 10 Knee walls - an air dam the full depth of the ceiling insulation is added to the exterior edge of the knee wall so the ceiling insulation overlaps the knee wall to the full depth of the ceiling insulation. 11 Attic access doors are insulated to the same R-value required by the CF1R for roof insulation and the insulation is permanently attached using adhesive or mechanical fasteners. The preferred method is rigid insulation. 12 Attic access forms an airtight seal from conditioned space to unconditioned space. Vertical attic access requires mechanical compression using screws, or latches. 13 Attic access must have a dam around the access to at least the same depth as the insulation. 14 Insulation batts must be cut to fit around cross bracings and truss webs. 15 Attic rulers appropriate to the material are installed and evenly distributed throughout the attic to verify depth (one ruler for every 250 ft2) The rulers are clearly readable from the attic access and scaled to read inches of insulation and the R-value installed. 16 Loose -fill and SPF insulation - a HERS rater shall measure the installed thickness (including low and high areas) and density of insulation in at least 6 random locations on roof/ceilings and floors to ensure minimum thickness levels and installed density necessary to meet the R-value specified on the Certificate of Compliance, and consistency with the manufacturer coverage chart. 17 Steel -framed knee walls, skylight shafts, and gable ends, external surfaces of steel studs are covered with insulation 18 Verification Status: Pass - all applicable requirements are met 19 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Wall Insulation 01 Batts, loose fill mineral fiber, mineral and natural wool, and cellulose: fills cavity and is in contact with air barrier on six sides. 02 ocSPF: completely fill cavities of 2x4 inch framing or less. Not required to fill cavities greater than 2x4 inch framing unless required to meet R-value. 03 ccSPF: insulation is not required to fill the cavities of framed assemblies unless required to meet R-value. 04 Double walls and bump -outs - insulation fills the cavity, or additional air barrier is installed so the insulation fills the cavity and is in contact with the insulation on all six sides unless SPF is used. Insulation shall be installed on the exterior of the double walls or bump -outs. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:06 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 4 of 7) D. Wall Insulation 05 Low expanding foam used around windows and doors, if allowed by the manufacturer. If not allowed fill cavity with insulation. Batts are not allowed to be stuffed into space. 06 Electrical panel in exterior insulated wall the panel is air tight and insulation is installed behind the panel. 07 Skylight shafts and attic knee wall insulation must meet all the requirements for walls and is in contact with the air barrier on six sides unless SPF is used. 08 Skylight shafts and attic kneewalls insulation shall be in full contact with the drywall or other interior wall finish. Batt insulation must be cut to fit around 2x4 framing that are laid flat. 09 Skylight shafts and attic kneewalls shall be completely enclosed by vertical and horizontal framing, including horizontal plates at top and bottom of the insulation. 10 Band/Rim joists are insulated to the same R-value as the wall. 11 Verification Status: Pass - all applicable requirements are met 12 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Raised Floor Insulation Quality 01 Insulation is in full contact with subfloor. 02 Insulation hangers are spaced at 18 inches or less, insulation hangers do not compress insulation. 03 Netting or mesh can be used if the cavity under the floor is filled and in contact with the subfloor. 04 When daylight basements are adjacent to crawlspaces, if the basement is conditioned the walls adjacent to the crawlspace are insulated to the R-value listed on the CF1R. This includes framed stem walls, and vertical concrete retaining walls. 05 If access to the crawlspace is from the conditioned area the raised floor includes an airtight insulated access hatch. Where possible locate crawl space access from the exterior. 06 Verification Status: Pass - all applicable requirements are met 07 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. F. Floor Above Garage Insulation Quality 01 Insulation must be in full contact with subfloor if the air barrier is at the band joist at the garage house wall. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page5of7) F. Floor Above Garage Insulation Quality 02 Insulation hangers spaced at 18 inches or less, insulation hangers must not compress insulation. 03 Netting or mesh can be used if the cavity under the floor is filled and in contact with the subfloor. 04 If air barrier is at the perimeter of the garage below the conditioned subfloor then the insulation may be placed on the garage ceiling. Perimeter of subfloor must also be insulated. 05 Verification Status: Pass - all applicable requirements are met 06 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. G. Cantilevered Floor Insulation Quality 01 Insulation is in full contact with cantilevered subfloor. Insulation hangers are spaced at 18 inches or less, insulation hangers do not compress insulation. Netting or mesh can be used if the cavity under the floor is filled and in contact with the subfloor. 02 Sealed Blocking shall be installed between joists where the wall rim joist would have been located in the absence of a cantilever. Insulation shall be placed on both sides of this block. 03 Verification Status: Pass - all applicable requirements are met 04 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. H. Attached Porch Roof Insulation Quality 01 Exterior wall at the intersection of the porch roof is fully insulated above, below and behind the roof line. 02 Where truss framing is used, airtight blocking is used at the top and bottom of each wall/roof section and insulated. 03 Verification Status: Pass - all applicable requirements are met 04 Correction Notes: The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page6of7) I. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-ENV-23-H Quality Insulation Installation (QII) Insulation Installation (Page 7 of 7) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-E23006A-E23A Registration Date/Time: 2022-01-21 06:30:19 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:06 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 Title 24, Part 6, Section 150.0(o) Ventilation for Indoor Air Quality. All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Equation and table numbering on this form corresponds to the numbering for that information in the published ANSI/SHRAE Standard 62.2-2010. A. Dwelling Mechanical Ventilation - General Information 01 Dwelling unit name Single Family Dwelling 02 Building Type Single family 03 Project scope Newly constructed building 04 Total Conditioned Floor Area of Dwelling Unit (For addition projects the conditioned floor area equals existing area plus addition area. ) 2112 05 Number of bedrooms in dwelling unit (For addition projects the number of bedrooms equals the existing bedrooms plus addition bedrooms) 3 06 Ventilation Operation Schedule Continuous 07 Whole -Building Ventilation Rate Calculation Method Fan Ventilation Rate Method (4.1.1) 08 Whole Building Ventilation System Type Standalone - Exhaust 09 IAQ Fan Location MCH-27a - Continuous Ventilation Airflow - Fan Ventilation Rate Method B. Whole -Building Continuous Ventilation - Fan Ventilation Rate Method A mechanical supply system, exhaust system, or combination thereof shall provide whole -building ventilation with outdoor air each hour at no less than the rate in equation 4.1a. 01 Required Continuous Whole -Building Ventilation Rate (Qfan) 51.12 02 Installed Continuous Whole -Building Ventilation Rate 75 C. Compliance Statement 01 Building passes continuous whole -building ventilation rate test Registration Number: 422-P010008074A-000-001-M 27008A-M 27A Registration Date/Time: 2022-01-21 06:29:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 2 of 3) D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-M 27008A-M 27A Registration Date/Time: 2022-01-21 06:29:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M 27008A-M 27A Registration Date/Time: 2022-01-21 06:29:47 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. System Information 01 Space Conditioning System Identification or Name Whole Housel 02 Space Conditioning System Location or Area Served bedrooms 03 Building Type from CF-1R Single family 04 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CF1R? No, credit is not taken 05 Verified Low Leakage Air Handling Unit Credit from CF1R? Yes credit is taken 06 Duct System Compliance Category New MCH-20c - Low Leakage Air -Handling Unit (LLAHU) B. Duct Leakage Diagnostic Test 01 Condenser Nominal Cooling Capacity (ton) 3 02 Heating Capacity (kBtu/h) 36 03 Conditioned Floor Area served by this HVAC system (ft2) 2112 04 Duct Leakage Test Conditions Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.06 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Cooling system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct Leakage Rate (cfm) 72 10 Actual Duct Leakage Rate from Leakage Test Measurement (cfm) 66 11 Air Handling Unit Manufacturer Name TRANE 12 Air Handling Unit Model Number TEM6A03611315BA Registration Number: 422-P010008074A-000-001-M 20009A-M 20A Registration Date/Time: 2022-01-21 06:29:50 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:04 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) B. Duct Leakage Diagnostic Test 13 Compliance Statement System passes leakage test 14 Notes: C. Additional Requirements for Compliance 01 The Low Leakage Air -handling Unit Model identified on this compliance document is included in the list of certified Low Leakage Air -Handling Units published on the Energy Commission Website at: http://www.energy.ca.gov/title24/equipment cert/Ilahu/low leakage air handling units.pdf 02 System was tested in its normal operation condition. No temporary taping allowed. 03 Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required, may configure the OA damper to the closed position during duct leakage testing. 04 All supply and return register boots were sealed to the drywall. 05 Building cavities were not used as plenums or platform returns in lieu of ducts. 06 If cloth backed tape was used it was covered with Mastic and draw bands. 07 All connection points between the air handler and the supply and return plenums are completely sealed. 08 Verification Status: Pass - all applicable requirements are met 09 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-M 20009A-M 20A Registration Date/Time: 2022-01-21 06:29:50 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M 20009A-M 20A Registration Date/Time: 2022-01-21 06:29:50 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 4) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Ducted Cooling System Information 01 System Identification or Name Whole Housel 02 System Location or Area Served bedrooms 03 System Installation Type New 04 Nominal Cooling Capacity (tons) of Condenser 3 05 Condenser Speed Type Single Speed 06 Cooling System Zonal Control Type Not Zonal 07 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 08 System Bypass Duct Status No Bypass Duct 09 Date of System Airflow Rate Measurement 2022-01-20 10 Airflow Rate Protocol Utilized RA3.3 procedures for airflow rate measurement B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently Installed Static Pressure Probe (PSPP) in the Supply Plenum. Procedures for installing HSPP or PSPP are specified in RA3.3.1.1. 01 Method Used to Demonstrate Compliance with the HSPP/PSPP Requirement HSPP installed and labeled consistent with Figure RA3.3-1 C. Airflow Rate Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given in RA3.3.2. 01 Airflow Rate Measurement Type used for this airflow rate verification. Traditional Flow Capture Hood according to procedure in RA3.3.3.1.4 02 Manufacturer of Airflow Measurement Apparatus alnor 03 Model number of Airflow Measurement Apparatus 371 04 Certification Status of the Airflow Measurement Apparatus Accuracy Certified by Manufacturer and listed on CEC Website at http://www.energy.ca.gov/title24/equipment_cert/ama_fas /index.html Registration Number: 422-P010008074A-000-001-M 23010A-M 23A Registration Date/Time: 2022-01-21 06:29:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:04 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 2 of 4) MCH-23a Forced Air System Airflow Rate Measurement - Newly Installed Non -Zoned Systems or Zoned Multi -Speed Compressor D. Forced Air System Airflow Rate Measurement The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3. 01 Required Minimum System Airflow Rate (cfm/ton) 350 02 Required Minimum System Airflow Target (cfm) 1050 03 Actual System Airflow Rate Measurement (cfm) 1074 04 Compliance Statement: System airflow rate complies E. Additional Requirements 01 Air filters that meet the applicable requirements of Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in the system during system air flow rate measurement identified on this Certificate of Verification. 02 The airflow rate measurement apparatus used to perform the airflow rate measurement identified on this Certificate of Verification was calibrated in accordance with the apparatus manufacturer's specifications and conforms to the instrumentation specifications given in RA3.3.1. 03 A visual inspection shall confirm system return duct airflow are not of Compliance indicates an allowance Certificate of Compliance, the airflow that bypass ducts that deliver conditioned supply air directly to the space conditioning used on newly constructed zonally controlled systems unless the Performance Certificate for use of a bypass duct. When a bypass duct is accounted for on the Performance rate shall conform to the specifications listed on the Certificate of Compliance. 04 All registers were fully open during the diagnostic test. 05 System fan was set at maximum speed during the diagnostic test. 06 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 07 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 08 Multi -speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 09 Verification Status: Pass - all applicable requirements are met 10 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table Registration Number: 422-P010008074A-000-001-M 23010A-M 23A Registration Date/Time: 2022-01-21 06:29:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:04 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 3 of 4) F. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-M 23010A-M 23A Registration Date/Time: 2022-01-21 06:29:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 4 of 4) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN 10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M 23010A-M 23A Registration Date/Time: 2022-01-21 06:29:53 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2016.2.000 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 3) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. Ducted Cooling System Information 01 System Identification or Name Whole Housel 02 System Location or Area Served bedrooms 03 System Installation Type New 04 Nominal Cooling Capacity (tons) of Condenser 3 05 Condenser Speed Type Single Speed 06 Cooling System Zonal Control Type Not Zonal 07 Central Fan Integrated (CFI) Ventilation System Status Not a CFI system 08 System Bypass Duct Status No Bypass Duct 09 Date of System Airflow Rate Measurement 2022-01-20 10 Airflow Rate Protocol utilized RA3.3 procedures for airflow rate measurement B. Fan Watt Measurement Apparatus and Procedure Information Instrument Specifications are given in RA3.3.1, and system fan watt measurement apparatus information is given in RA3.3.2.2. 01 Fan Watt Verification Device Used. Portable watt meter MCH-22a Forced Air System Fan Efficacy Measurement - Newly Installed Non -Zoned Systems or Zoned Multi -Speed Compressor C. Forced Air System Fan Efficacy Measurement The procedures for System Fan Watt Verification are specified in Reference Residential Appendix RA3.3 01 Actual Tested Watts 621 02 Actual Tested Airflow from MCH-23 (cfm) 1074 03 Required Fan Efficacy (watts/cfm) 0.58 04 Actual Fan Efficacy (watts/cfm) 0.58 05 Compliance Statement: System fan efficacy complies Registration Number: 422-P010008074A-000-001-M 22011A-M 22A Registration Date/Time: 2022-01-21 06:29:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:04 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 2 of 3) D. Additional Requirements 01 All registers were fully open during the diagnostic test. 02 System fan was set at maximum speed during the diagnostic test. 03 If fresh air duct is part of the HVAC system it was not closed during the diagnostic test. 04 Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value. 05 Multi -speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air handler fan speed. 06 Zoned cooling air distribution systems with single speed compressors shall meet both the airflow (cfm/ton) and fan efficacy (Watt/cfm) criteria in every zonal control mode. 07 Verification Status Pass - all applicable requirements are met 08 Correction Notes The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. E. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-M 22011A-M 22A Registration Date/Time: 2022-01-21 06:29:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 3 of 3) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN 10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M 22011A-M 22A Registration Date/Time: 2022-01-21 06:29:57 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:04 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 1 of 4) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. System Information HERS Rater to field -verify all system information, discrepancies to be noted by overwriting entry. 01 System Identification or Name Whole Housel 02 System Location or Area Served bedrooms 03 Condenser (or package unit) make or brand TRANE 04 Condenser (or package unit) model number 4TWR6036H1000 05 Nominal Cooling Capacity (tons) of Condenser 3 06 Condenser (or package unit) serial number 2020170W4F 07 Refrigerant Type R-410A 08 Other Refrigerant Type (if applicable) This field or section is not applicable 09 Liquid Line Filter Drier Installed According to Manufacturers Specifications (if applicable) Yes 10 System Installation Type New 11 Fault Indicator Display (FID) Status (Note: Even systems with a FID must have refrigerant charge verified by installer) This system does not have a FID device installed 12 Is the system of a type that the minimum airflow can be verified using an approved measurement procedure (RA3.3 or RA3.3.3)? Yes, this is a ducted system and one of the system airflow rate measurement procedures in RA3.3 or RA3.3.3 can be used to verify system airflow rate requirements. 13 Is the system of a type that approved refrigerant charge verification procedures can be used to verify compliance with the refrigerant charge verification requirements when temperatures are >= 55°F (RA3.2.2, or RA1)? Yes, one of the Refrigerant charge verification procedures from RA3.2.2 or RA1 is applicable to this system and can be used to verify compliance 14 Date of Refrigerant Charge Verification for this system 2022-01-20 15 Refrigerant charge verification method used. Subcooling (outdoor temperature must be equal to or greater than 55 degF) 16 Person who performed the Refrigerant Charge Verification reported on this Certificate of Installation HVAC system installer 17 HERS Verification Compliance Requirement Status System qualifies for group sampling 18 Refrigerant charge verification method used by HERS Rater. Subcooling Registration Number: 422-P010008074A-000-001-M 25012A-M 25A Registration Date/Time: 2022-01-21 06:30:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:05 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 2 of 4) MCH-25b - Refrigerant Charge Verification - Subcooling Method B. Metering Device Verification HERS Rater is required to visually field verify all information from CF2R. Subcooling Method can only be used on systems that have a variable metering device. 01 Refrigerant metering device Thermostatic Expansion Valve (TXV) 02 Subcooling Method applicability status Subcooling Method is applicable to this system. C. Instrument Calibration HERS Raters are required to calibrate their diagnostic tools. Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Date of Digital Refrigerant Gauge Calibration 2022-01-20 02 Date of Digital Thermocouple Calibration 2022-01-20 03 Digital Refrigerant Gauge Calibration Status Calibration is current 04 Digital Thermocouple Calibration Status Calibration is current D. Measurement Access Hole (MAH) Verification HERS Raters are required to visually field verify MAH. Procedures for installing MAH are specified in Reference Residential Appendix RA3.2.2.3 01 Method Used to Demonstrate Compliance with the Measurement Access Hole (MAH) Requirement MAH installed and labeled consistent with Figure 3.2-1 E. Minimum System Airflow Rate Verification Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.3.3. 01 Minimum Required System Airflow Rate (cfm) 1050 02 System Airflow Rate Verification Status System complies with minimum airflow rate requirements F. Data Collection and Calculations HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 01 Lowest Return Air Dry Bulb Temperature that Occurred During the Refrigerant Charge Verification Procedure (°F) 70 02 Measured Condenser Air Entering Dry -Bulb Temperature (Tcondenser, db) 74 Registration Number: 422-P010008074A-000-001-M 25012A-M 25A Registration Date/Time: 2022-01-21 06:30:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:05 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 3 of 4) F. Data Collection and Calculations HERS Rater must independently collect all data in this section. Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2 03 Outdoor Temperature Qualification Status Outdoor temperature is within range for using Subcooling refrigerant charge verification method 04 Measured Liquid Line Temperature (Tuquid) (°F) 102.3 05 Measured Liquid Line Pressure (Puquid) (psig) 245.2 06 Condenser Saturation Temperature (Tcondenser, sat) from Digital Gauge or P-T Table using Line F05 (°F) 116.6 07 Measured Subcooling (Line F06 - Lilne F04 (°F) 14.3 08 Target Subcooling from Manufacturer (°F) 12 09 Compliance Statement: System complies with Subcooling Method - Must also pass metering device verification, next section G. Metering Device Verification HERS Rater must independently collect all data in this section. Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2 01 Measured Suction Line Temperature (Tsuction) (°F) 70.2 02 Measured Suction Line Pressure (Psuction) (psig) 114.2 03 Evaporator Saturation Temperature (Tevaporator, sat) from Digital Gauge or P-T Table using Line G02 (°F) 59.6 04 Measured Superheat (Line G01- Line G03) (°F) 10.6 05 Measured Superheat (Line G04) is between 3°F and 26°F (inclusive) Passes CEC requirement 06 Measured Superheat (Line G04) is within Manufacturer's Specifications ( if known) Yes, documentation to be provided upon request 07 Compliance Statement: Metering device verification passes H. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-M 25012A-M 25A Registration Date/Time: 2022-01-21 06:30:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-25-H Refrigerant Charge Verification (Page 4 of 4) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN 10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M 25012A-M 25A Registration Date/Time: 2022-01-21 06:30:09 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 1 of 4) Project Name: Pepe Builds Chihuahua Enforcement Agency: City La Quinta, of Permit Number: 2021 Dwelling Address: 77-285 Calle Chihuahua City: La Quinta Zip Code: 92253 A. System Information Procedures for verification of High SEER and EER Equipment are described in Reference Appendix RA3.4. Each HVAC system requiring verification must use a separate form. 01 System Name or Identification/Tag Whole Housel 02 System Location or Area Served bedrooms 03 Status: SEER and EER performance compliance credit check Both SEER and EER HERS Verification is required 04 Directory used to certify product performance AHRI 05 AHRI certification number for the installed space conditioning system from http://www.ahridirectory.org 1224588858 06 Does the directory used to certify product performance require a specific air handler/furnace make and model? No 07 Does the directory used to certify product performance require a time delay relay (+TDR)? Yes 08 Does the directory used to certify product performance require a TXV (+TXV)? Yes B. Rated Space Conditioning System Equipment Verification The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. Data from Nameplate of Installed System Component Data from the Directory Used to Certify the Rated System Component Outdoor Condenser or Package Unit - Installed Manufacturer Name 01 TRANE 02 TRANE Outdoor Condenser or Package Unit - Installed Model Number 03 4TWR6036H1000 04 4TWR6036H1000 Inside Coil - Installed Manufacturer Name 05 NA 06 NA Inside Coil - Installed Model Number 07 NA 08 NA Air Handler/Furnace - Installed Manufacturer Name 09 TRANE 10 TRANE Registration Number: 422-P010008074A-000-001-M 26013A-M 26A Registration Date/Time: 2022-01-21 06:30:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 2 of 4) B. Rated Space Conditioning System Equipment Verification The data on nameplate of the installed component shall conform to the data for the component as shown in the Directory used to certify product performance in order to demonstrate compliance. Air Handler/Furnace - Installed Model Number 11 TEM6A03611315BA 12 TEM6A03611315BA C. Verified Cooling System SEER 01 Required minimum SEER 16 02 Installed SEER 16 03 Compliance Statement: System passes SEER verification Signature by responsible party below certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. D. Verified Cooling System EER 01 Required minimum EER 13 02 Installed EER 13 03 Compliance Statement: System passes EER verification Signature by responsible party below certifies that the installed cooling equipment meets or exceeds the required value listed on the CF2R. E. Verified Cooling System Air Handler/Furnace This section does not apply to this project. F. Verified Cooling System Time Delay Relay 01 If a Time Delay Relay is required by the directory used to certify product performance, the responsible party certifies by signing below that the Time Delay Relay is installed and has been tested to operate correctly according to the protocols of RA3.4.3. 02 Verification Status: Pass - all applicable requirements are met 03 Correction Notes: G. Verified Cooling System TXV 01 If a TXV is required by the directory used to certify product performance, the responsible party certifies by signing below that the TXV is properly installed and has been visually verified, including proper placement of sensing bulb Registration Number: 422-P010008074A-000-001-M 26013A-M 26A Registration Date/Time: 2022-01-21 06:30:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards 2016 Residential Compliance Report Version: 2018.0.001 Schema Version: rev 20180426 Report Generated: 2022-01-21 06:40:05 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 3 of 4) G. Verified Cooling System TXV 02 Verification Status: Pass - all applicable requirements are met 03 Correction Notes: The responsible person's signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. H. Determination of HERS Verification Compliance All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 422-P010008074A-000-001-M 26013A-M 26A Registration Date/Time: 2022-01-21 06:30:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CERTIFICATE OF VERIFICATION CF3R-MCH-26-H Rated Space Conditioning System Equipment Verification (Page 4 of 4) Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Tom Bachus Documentation Author Signature: ro-vni Bab,cium, Company: MLC Building Performance Date Signed: 2022-01-21 Address: 77825 Delaware Place CEA/ HERS Certification Identification (if applicable): RCN10140 City/State/Zip: Palm Desert CA 92211 Phone: 760-360-0066 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): Compressor Air Conditioning and Heating Responsible Builder or Installer Name: David Leal CSLB License: 957516 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) N/A HERS Rater Information HERS Rater Company Name: MLC Building Performance Responsible Rater Name: Tom Bachus Responsible Rater Signature: ro-vn/ '3c hko, Responsible Rater Certification Number w/ this HERS Provider: RCN10140 Date Signed: 2022-01-21 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010008074A-000-001-M 26013A-M 26A Registration Date/Time: 2022-01-21 06:30:12 HERS Provider: CHEERS CA Building Energy Efficiency Standards Report Version: 2018.0.001 Report Generated: 2022-01-21 06:40:05 2016 Residential Compliance Schema Version: rev 20180426 NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. NTRUCTURAL ENGINEERING, INC. CIVIL AND STRUCTURAL ENGINEERING Palm Desert Tel: 760-360-9998 Fax: 760-360-9903 Email: Reza@rastructural.com www.Rastructural.com STRUCTURAL OBSERVATION REPORT FRAMING ONLY January 8, 2021 City of La Quinta Building And Safety Department Re.: 77285 Calle Chihuahua La Quinta, CA. Gentlemen, We have performed structural observation per 2016 C.B.C. section 1704 for the framing condition prior to drywall and stucco. Based on our visual observation and to the best of our knowledge and experience, we believe that the framing that was completed at the time of our visit, per approved plans. Please note that this letter does not include or waive the responsibility for the City or the Special Inspectors from determining compliance with the approved plans. Please contact me should you need additional information regarding this approval. Respectfully, 0,- Reza Asgharpo r, P.E. • <sG rf '4 •( g, tuf G ;:3,:t\l'icc, : - - io.CB'R?3m'' jr .4 ,qIt (IF Gr\-\ .:,'''.. 77570 Springfield Lane, Ste D, Palm Desert CA 92211 JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 Phone: 760-275-5020 - Fax: 760-327-8907 jINSPECTIONS RA INSPECTIONS INSPECTION REPORT Date:q 10 Project Name: Project No: 20-915A Cosa Chi, LLC Project Address: City: 77-285 Calle Chihuahua La Quinta, CA Client: Sub -Contractor: Owner General Contractor: Architect: Structural Engineer: Coronet Enterprises RA [✓, IBC [71 Title 24 Other: Q C Unresolved Items: None See Below Description C\Ne.A� of Work Inspected: ±n Non -Shrink Grouting _UG--1..0_O__ - OEM S �,LL C'6 4 — Q ,_ 0 oil Sirm'i ,__ Oa_ WkJ2, __ "_a_o,__________ os5k ��_s= 4 ROt____ — 1t r °:":17-- • Cf2t11 O'NNS 5---s-1-_/ CSL3l`n "L Ci)i .t) 1n _ c r1C r m (s,1 0*.1-_,_,.).94Ao_t_ _Ol -`cu R_ • i" sal ��t e� • Jo0.0. I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifica 'ons _applicable building laws. Final report issued at project completion. =j Inspector: Ja C. 'llin t C lc 0842216 4iiiii, Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page 4_ of JHA ENGINEERS CIVIL ENGINEERS • LAND SURVEYORS • LAND PLANNERS September 8, 2020 Counter Technician City of La Quinta, Public Works Department PO Box 1504 La Quinta, CA 92247-1504 RE: Pad and Form Certification APN: 774-041-001 and 002 Legal Description: Parcel A of Parcel Map Waiver 2019-0001 Site Address: 77285 Calle Chihuahua Dear Counter Technician This letter is to verify that the locations and elevation of the building pad were field checked by JHA Engineers and found to be in substantial conformance with the approved Grading Plan that was prepared by our office and with the City of La Quinta Standards. The results are as follows: Casita Main Residence Pad Elevation 102.3 Pad Elevation 101.8 High Side Top of Curb 103.82 High Side Top of Curb 100.04 Mid Top of Curb 102.38 Mid Top of Curb 99.60 Low Side Top of Curb 100.94 Low Side 99.16 Finish Floor 0.42 foot above mid point (Finish Floor 102.80) Finish Floor 2.7 above mid point (FF 102.3) Setbacks includes the Main Residence with Casita as one building envelope. Front 20.0 ft Right 10.0 ft Left 15.0 ft Rear 10.0 ft If you have any questions, please contact our office. Respectfully, . Hacker Exp. 3/31/21 R.C.E. 14614 JHH/sbg 185549p.001 Pad and Form Cert 43585 MONTEREY AVENUE, SUITE 7 PALM DESERT, CA 92260 760-345-1352 1 Building Permit Number. Project Description: SFR Exempt: 0 (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan Plan Submittal Date Job Site Address Owner's Name Number, Street, or PO Box City, State, Postal Code Owner's Phone Number Owner's E-Mail Address Project Manager's Name Project Manager's Phone Number Project Manager's E-mail Address Builder / Contractor Number, Street or PO Box City, State, Postal Code Project Square Footage Approval By Burrtec Date of City Approval 6/11/2020 77285 CALLE CHIHUAHUA MM WILSON ZEKE CORONEL 760-578-3446 ish@coronelent.com CORONEL ENT 42760 MADIO ST INDIO, CA.92201 2,440 Materials To Be Discarded: Product Trash Asphalt Brick/Block Cardboard Commingled Concrete Drywall Donated / Reuse* *Describe Items Tons Not recyclable Recyclable Recyclable Recyclable Recyclable Recyclable Recyclable Recyclable 9.00 0.00 0.00 0.65 0.00 12.00 1.25 0.00 Product Masonry (broken) Plaster Scrap Metal Tile (floor) Tile (roof) Wood Landscape Debris Tons Recyclable Recyclable Recyclable Recyclable Recyclable Recyclable Recyclable 0.00 3.00 0.00 0.25 0.35 4.50 0.00 Totals: Recycle 22.0 Trash 9.0 Projected Diversion: 70.97% I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 65% of the jobsite waste is diverted from Iandfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self - hauling, all refuse material from this project site must be taken to an approved recycler or transfer station. Date: 6/30/2020 No.: 20-01701-1 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760)771-8515 Owner: Wilson Jack M & Majel A Email: Address: 77285 Calle Chihuahua Jurisdiction: La Quinta City: La Quinta Tract #: Type: Single Family Residential Lot # Street No. 77285 Comments: Street Name Sq. Feet APN Calle Chihuahua 2440 774-041-001 DESERT SANDS UNIFIED SCHOOL DISTRICT Permit No. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement mobile homes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fess imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $4.08 X 2440 S.F. or $9,955.20 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in the proposed project may now be issued. Fees Paid By: CC/ Wells Fargo/ Ish Coronel Bank Name/Recipient of Certificate By Scott L. Ba i ley Superintendent Check No.: 7234705624 Telephone: Funding: Residential Fee Collected/ Exempted by: Yazmin Henry Certificate Fees Due: $9,955.20 Original Paymert(s) Rec'd: $0.00 New Payment Rec'd: $9,955.20 Over/Under: $0.00 NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. Notice to Building Department: THIS DOCUMENT VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.