BMCH2018-0132Permit Details
City of La Quinta
Description: HVAC INSTALL / CHANGEOUT
Type: MECHANICAL - HVAC Subtype: Status: FINALED
CHANGEOUT (WEB)
Applied: 4/24/2018 ECON
Approved: 4/25/2018 MFA
Issued: 4/25/2018 MFA
Finaled: 7/19/2018 crw
Expired:
Parcel No: 773152022 Site Address: 51935 AVENIDA CORTEZ LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 29 Lot: 10
UNIT 2
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $15,000.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: HVAC CHANGE OUT - 25 SEER/80AFUE SPLIT SYSTEM. CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION.
2016 CALIFORNIA BUILDING CODES.
Process Summary
85
1
Applied to Approved
Approved to Issued
Issued to Finaled
ADDITIONAL SITES
CHRONOLOGY
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
VOTTA ENTERPRISES INC DBA
COMFORT AIR
72248 NORTHSHORE ST
STE 101
THOUSAND
PALMS
CA
92276
(760)320-5800
kellypennington@comf
ortac.com
CONTRACTOR
VOTTA ENTERPRISES INC DBA
COMFORT AIR
72248 NORTHSHORE ST
STE 101
THOUSAND
PALMS
CA
92276
(760)320-5800
kellypennington@comf
ortac.com
OWNER
TINA HAURUM
51935 AVENIDA
CORTEZ
LA QUINTA
CA
92253
(
FINANCIAL INFORMATION
Printed: Wednesday, June 28, 2023 10:12:14 AM
1 of 3
CRWSYSTEMS
Permit Details PERMIT NUMBER
City of La Quinta BMCH2O18-0132
jA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
■ ■
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$1.00
4/24/18
WEB2512
CREDIT
VOTTA ENTERPRISES
INC DBA COMF
ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00
BSA:
$1.00
HVAC CHANGEOUT
SPLIT -SYSTEM
101-0000-42402
0
$39.01
$39.01
4/24/18
WEB2512
CREDIT
VOTTA ENTERPRISES
INC DBA COMF
ECON
HVAC CHANGEOUT
SPLIT -SYSTEM PC
101-0000-42600
0
$78.02
$78.02
4/24/18
WEB2512
CREDIT
VOTTA ENTERPRISES
INC DBA COMF
ECON
Total Paid for CHANGEOUT: $117.03
$117.03
Credit Card Fee
101-0000-43505
0
$3.99
$3.99
4/24/18
WEB2512
CREDIT
VOTTA ENTERPRISES
INC DBA COMF
ECON
Total Paid for Credit Card Fee: $3.99
$3.99
PERMIT ISSUANCE
101-0000-42404
0
$98.83
$98.83
4/24/18
WEB2512
CREDIT
VOTTA ENTERPRISES
INC DBA COMF
ECON
Total Paid for PERMIT ISSUANCE: $98.83
$98.83
TECHNOLOGY
ENHANCEMENT FEE
502 0000 43611
I 0
$5.00
$5.00
4/24/18
WEB2512
CREDIT
VOTTA ENTERPRISES
INC DBA COMF
ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00
$5.00
TOTALS:
$225.85
$225.85
INSPECTIONS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
MECHANICAL FINAL**
DCL
7/19/2018
7/19/2018
APPROVED
PARENT PROJECTS
REVIEWS
REVIEW TYPE REVIEWER SENT DATE DUE DATE I REDATE
STATUS
REMARKS
NOTES
Printed: Wednesday, June 28, 2023 10:12:14 AM
2 of 3
CRWSYSTE S
vigil.
Permit Details
City of La Quinta
PERMIT NUMBER
BMCH2O18-0132
1ST PERMIT TECH —
ETRAKIT (1 DAY)
MARY4/24/2018 4/25/2018 4/25/2018 I APPROVED
FASANO
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
4/24/2018
EtrakitContractor
CF1R
638849ad6e4345c878cf
6ceee397292be5dd9516
.pdf
1
Printed: Wednesday, June 28, 2023 10:12:14 AM 3 of 3
CRWSYSTE S
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 1 of 3)
Project Name:
TINA HAURUM
Date Prepared:
2018-04-24
A. General Information
CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CF1R-ALT-02 document for each dwelling unit.
01
Project Name
TINA HAURUM
02
Date Prepared
2018-04-24
03
Project Location
51935 AVENIDA CORTEZ
04
Building Type
Single family
05
CA City
La Quinta
06
Dwelling Unit Name
HOUSE
07
Zip Code
92253
08
Dwelling Unit Conditioned
Floor Area (ft2)
1479
09
Climate Zone
15
10
Number of Space
Conditioning (SC) Systems in
this Dwelling Unit:
1
B. Space Conditioning (SC) System Information
01
02
03
04
05
06
07
08
09
10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System (ft2)
Is the SC
system a
ducted
system?
Installing a
refrigerant
containing
component?
Installing new SC
system
components?
Installing
more than 40
feet of ducts?
Installing
entirely new
duct system?
Installing
entirely new
SC system?
Alteration Type
SYSTEM 1
LOCATION 1
1479
Yes
Yes
Yes
No
No
No
Altered space
conditioning system
C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib)
This section does not apply to this project.
Registration Number: 418-A020025997A-000-000-0000000-0000
Registration Date/Time: 2018-04-24 13:13:08
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version: 2016.1.006
Schema Version: rev 10/16
Report Generated: 2018-04-24 13:13:09
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System Sections 150.2(b)1E and F)
01
02
03
04
05
06
07
08
09
10
11
12
System
Identification
or Name
Heating
System
Type
Altered
Heating
Components
Heating
Efficiency
Type
Heating
Minimum
Efficiency
Value
Cooling
System Type
Altered
Cooling
Components
Cooling
Efficiency
Type
Cooling
Minimum
Efficiency
Value
Required
Thermostat
Type
New or
Replaced
Duct Length
New Duct
R-Value
SYSTEM 1
Central gas
furnace
All new
heating
components
AFUE
0.8
Central split
AC
All new
cooling
components
SEER
25
Setback
This field or
section is not
applicable
This field or
section is not
applicable
Required Documentation:
Systems
new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced
<= 10% leakage to outside, or seal all accessible leaks.
Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
>= 300 CFM per ton required when MCH-25 is required.
provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements.
CF2R-MCH-01-E - Space
- Duct insulation requirement
CF2R and CF3R-MCH-20-H
-Leakage rate compliance:
CF2R and CF3R-MCH-25-H
CF2R and CF3R-MCH-23
Exceptions:
Conditioning
for the
- Duct Leakage
<= 15% or
Refrigerant
Airflow Rate
with HERS
and Air Handler
constructed, insulated
- Duct systems registered
- Heating -only systems
-Existing duct systems
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C)
This section does not apply to this project.
Registration Number: 418-A020025997A-000-000-0000000-0000
Registration Date/Time: 2018-04-24 13:13:08 HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2016.1.006 Report Generated: 2018-04-24 13:13:09
Schema Version: rev 10/16
CERTIFICATE OF COMPLIANCE
CF1R-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)
(Page 3 of 3)
Documentation Author's Declaration Statement
1. I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Patty Hernandez
Documentation Author Signature:
Pattiyiferhandeis,
Company:
I Permit E Raters
Signature Date:
2018-04-24
Address:
31225 La Baya Drive
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Westlake Village CA 91362
Phone:
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
5. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Tracy Garza
Responsible Designer Signature:
Tracy Garza,
Company :
Votta Enterprises, Inc. dba Comfort Air
Date Signed:
2018-04-24
Address:
72248 Northshore Street #101
License:
763937
City/State/Zip:
Thousand Palms CA 92276
Phone:
760-320-5800
Digitally signed by CHEERSTM. This digital signature is provided in order to secure the content of this registered
document, and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 418-A020025997A-000-000-0000000-0000 Registration Date/Time: 2018-04-24 13:13:08
HERS Provider: CHEERS
CA Building Energy Efficiency Standards - 2016 Residential Compliance
Report Version: 2016.1.006 Report Generated: 2018-04-24 13:13:09
Schema Version: rev 10/16