BCOM2021-0079 Title 24I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Rapport - La Quinta
44125 Jefferson St
La Qu i nta, CA 92253
Project Designer:
82410 Padova dr
BCOM2021-0079
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
BY: A DATE: 0112712022
Indio, CA 92203
13,916SF RETAIL STORE
(760) 774-3487
WITH STORAGE TI/VB/M,
S-OCC/126-OL/SPRINKLED
[RAPPORT RM FURNITURE]
THIS PERMIT DOES NOT
Report Prepared by:
INCLUDE BUILDING
SIGNAGE, STORAGE RACKS
Arash Nazari
OR PLUMBING
A & N Design Group
ALTERATIONS. TUMF AND
21550 Oxnard Street #300
DIF NOT ASSESSED BASED
Woodland Hills, CA, CA 91367
ON NO CHANGE OF USE OR
ADDITIONAL SQUARE
818-288-4361
FOOTAGE. 2019 CALIFORNIA
BUILDING CODES.
A & N
DESIGN GROUP
Job Number:
287
Date:
1/24/2022
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form NRCC-LTI-E Indoor Lighting
Form NRCC-MCH-E Mechanical Systems
2
3
10
STATE OF CALIFORNIA
Indoor Lighting
N RCC-LTI-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
This document is used to demonstrate compliance with requirements in 110.9 §110.12(c), 130.0 130.1 140.6 and §141.0(b)2 for indoor lighting scopes using the prescriptive
path.
Project Name: Rapport - La QuintaReport Page: (Page 1 of 7)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
A. GENERAL INFORMATION
01
Project Location (city)
La Quinta
04
Total Conditioned Floor Area (ft2) 14,416
02
Climate Zone
15
05
Total Unconditioned Floor Area (ft2) 0
03
Occupancy Types Within Project (select all that apply):
06
# of Stories (Habitable Above Grade) 1
®
Office 10 IRetail 10 1warehouse
❑
Hotel/Motel ❑ School Areas
® Altered Lighting System
n
g Garage ❑ High -Rise Residential ElRelocatable
ElHealthcare
Tport
ElOther (Write in)See Table I
B. PROJECT SCOPE
This table includes any lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in1§ 40.6 or
§141.0(b)2 for alterations.
Scope of Work
Conditioned Spaces
Unconditioned Spaces
01
02 03
04 05
My Project Consists of (check all that apply):
Calculation Method Area (ft2)
Calculation Method Area (ft2)
❑ New Lighting System
❑ New Lighting System - Parking Garage
® Altered Lighting System
n
Area Category Method 14416
Area Category Method 0
Total Area of Work (ft2)
14416
0
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Indoor Lighting
N RCC-LTI-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: Rapport - La Quints Report Page: (Page 2 of 7)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
C. COMPLIANCE RESULTS
If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance.
Designed Wattage: Conditioned Spaces
Allowed Lighting Power per §140.6 b (Watts)
02
Adjusted Lighting Power per §140.6(a)
(Watts)
05
Compliance Results
Lighting in
08
09
01
02
03
04
Small Aperture &
05
06
07
Excluded per
08
09
conditioned and
Fail
Tag
Description
(Track) Fixture
Color Changer
luminaireZ
Area
of Luminaires
§140.6(a)3
Adjustments
Lithonia JCBL-LED Damp
No
unconditioned
84
Mfr. Spec
33
No
2,772
❑
❑
Rated High Bay
PAF LightingTotal
spaces must not be
Complete
Area
Category
Tailored
Total
>
Total
Adjusted
�
combined forAllowed
Building
Category
Additional§140.6(c)3
=
Designed
Control Credits
=
(Watts)
Watts
05 must be >= 08
compliance per
§140.6(c)1
§140.6(c)2
§140.6(c)2G
( +)
(Watts)
(Watts)4140.6(a)2
*Includes
140.6
§140.6(b)1
( +)
(-)
Adjustments
(See Table 1)
(See Table I)
(See Table J)
(See Table K)
(See Table F)
(See Table P)
Conditioned
8,109.5
0
=
8,110
>_
7,744
0
=
7744
COMPLIES
Unconditioned
Controls Compliance (See Table
H for Details)
COMPLIES
Rated Power Reduction Compliance (See Table Q for Details)
D. EXCEPTIONAL CONDITIONS
This table is auto filled with uneditable comments because of selections made or data entered in tables throughout the form.
E. ADDITIONAL REMARKS
This table includes remarks made by the permit applicant to the Authority Having Jurisdiction.
F. INDOOR LIGHTING FIXTURE SCHEDULE
This table includes all permanent designed lighting and all portable lighting in offices.
Designed Wattage: Conditioned Spaces
01
02
03
04
05
06
07
08
09
10
Name or Item
Complete Luminaire
Modular
Small Aperture &
Watts per
How is Wattage
Total Number
Excluded per
Design Watts
Field Inspector
Pass
Fail
Tag
Description
(Track) Fixture
Color Changer
luminaireZ
determined
of Luminaires
§140.6(a)3
T1
Lithonia JCBL-LED Damp
No
No
84
Mfr. Spec
33
No
2,772
❑
❑
Rated High Bay
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Indoor Lighting
N RCC-LTI-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: Rapport - La Quints Report Page: (Page 3 of 7)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
F. INDOOR LIGHTING FIXTURE SCHEDULE
T2 JUNO 351-170
Yes No
660
Mfr. Spec 7
No 4,620 ❑ ❑
T3 Lithonia LDN4
No No
32
Mfr. Spec 11
No 352 ❑ ❑
Total Designed Watts: CONDITIONED SPACES 7,744
'FOOTNOTE: Design Watts for small aperture and color changing luminaires which qualify per §140.6(a)4B is adjusted to be 75% of their rated wattage. Table F automatically makes
this adjustment, the permit applicant should enter full rated wattage in column 05.
ZAuthority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per 4130.0(c) Wattage used must be the maximum rated for the luminaire, not
the lamp.
G. MODULAR LIGHTING SYSTEMS
This table includes lighting controls for conditioned and unconditioned spaces. When a control having a * is shown, the notes section of this table provides more detail on how
compliance is achieved. The lighting controls section of the Compliance Summary Table on the first page will show "DOES NOT COMPLY" if the notes are left blank.
Building Level Controls
01 02
03
This table calculates wattage for modular lighting systems/ track lighting fixtures indicated on Table F and transfers wattage to Table F.
Field Inspector
Pass I Fail
01
02
03
04
Name or
Complete Track Description
Calculation Method per §130.0(66
Track
Item Tag
Wattage
iv Power supplied by
T2
JUNO 351-170
®
i Installed Luminaires
Elii
Current Limiter
ElPanel
iii Overcurrent Protection
Eldriver,
power supply or
vs Default 30 W/ft
transformer'
Rated
Default
Number of luminaires in
Watts per
Total Watts
Linear ft of track or
W/LF
Total Watts
system
X
luminaire
-
OR
busway
X
30
-
660
22
30
660
'FOOTNOTE: For power -over -Ethernet lighting systems, power provided to installed non -lighting devices may be subtracted from the total power rating of the power -over -Ethernet
system.
H. INDOOR LIGHTING CONTROLS (Not including PAFs)
This table includes lighting controls for conditioned and unconditioned spaces. When a control having a * is shown, the notes section of this table provides more detail on how
compliance is achieved. The lighting controls section of the Compliance Summary Table on the first page will show "DOES NOT COMPLY" if the notes are left blank.
Building Level Controls
01 02
03
Mandatory Demand Response §110.12(c) Shut-off controls §130.1(c)
Field Inspector
Pass I Fail
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Indoor Lighting
N RCC-LTI-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: Rapport - La Quints Report Page: (Page 4 of 7)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
H. INDOOR LIGHTING CONTROLS (Not including PAFs)
Not Required <= 10,000 SF
Whole Building Auto Time Switch
❑
❑
Area Level Controls
04
05
06
07
08
09
10
11
12
Allowed Wattage
(Watts)
Additional Allowance / Adjustment
Area Category PAF
Storage Area
Commercial Industrial Storage Area
Primary/SkySecondary
10,837
4,876.7
No No
Complete Building or Area
Area Controls
Multi -Level
Shut -Off Controls
lit
Interlocked
Field Inspector
Area Description
Category Primary Function
130. 1 a
Controls
130.1 c
Daylighting
Daylighting
Systems
Area
§130.1(b)
§130.1(d)
§140.6(d)
§140.6(a)1
Pass
Fail
RESTROOM
Restrooms
ManualS
Manual
Dimmer
Occupancy Sensor
N/A
N/A
No
❑
❑
Offices
Office 250 square feet or less
Manual Manual
Dimmer
Occupancy Sensor
Included
Included
No
❑
❑
Sales Area
All Other Space Types
Manual Manual
Dimmer
Occupancy Sensor
Included
Included
No
❑
❑
Furniture Storage
Warehouse
Manual ManualDimmer
Occupancy Sensor
Included
Included
No
El
El
Breakroom
Office 250 square feet or less
Manual ManualDimmer
Occupancy Sensor
N/A
N/A
I
No
❑ON/OFF
El
*NOTES: Controls with a * require a note in the space below explaining how compliance is achieved.
13
EX: Conference 1: Primary/Skylight Daylighting: Exempt because less than 120 watts of general lighting; EXCEPTION 1
to §119.1(d)2
Plan Sheet Showing Daylit Zones:
I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS
Each area complying using the Complete Building or Area Category Methods per §140.6(b) are included in this table. Column 06 indicates if additional lighting power allowances per
§140.6(c) or adjustments per 114Q.6LaI are being used.
Conditioned Spaces
01
02
03
04
05
06
Area Description
Complete Building or Area Category Primary
Function Area
Allowed Density
(W/ftZ )
Area (ft Z)
Allowed Wattage
(Watts)
Additional Allowance / Adjustment
Area Category PAF
Storage Area
Commercial Industrial Storage Area
0.45
10,837
4,876.7
No No
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Indoor Lighting
NRCC-LTI-E CALIFORNIA ENERGY COMMISSION
'ERTIFICATE OF COMPLIANCE NRCC-LTI-1
3roject Name: Rapport - La Quinta Report Page: (Page 5 of 7
3roject Address: 44125 Jefferson St Date Prepared: 1/24/202:
I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS
Showroom
Retail Merchandise Sales 1
2,490
2,490
No
No
Loading
Office 250 square feet or less 0.7
300
210
No
No
RESTROOM
Restrooms 0.65
389
252.8
No
No
OFFICE & BREAI<ROOM
Office 250 square feet or less 0.7
400
280
No
No
TOTALS:
14,416
8,109.5
See Tables J, or P for detail
I. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM
-his section does not apply to this project.
<. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE
-his section does not apply to this project.
_. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY
-his section does not apply to this project.
VI. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING
Fhis section does not apply to this project.
V. ADDITIONAL LIGHTING ALLOWANCE: TAILORED ORNAMENTAL/SPECIAL EFFECTS
Fhis section does not apply to this project.
3. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE
Fhis section does not apply to this project.
:. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF))
-his section does not apply to this project.
:1. RATED POWER REDUCTION COMPLIANCE FOR ALTERATIONS
Fhis section does not apply to this project.
Registration Number: Registration Date/Time: Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Indoor Lighting
N RCC-LTI-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-LTI-E
Project Name: Rapport - La Quints Report Page: (Page 6 of 7]
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS
This section does not apply to this project.
S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF)
This section does not apply to this project.
T. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION
Selections have been made based on information provided in this document. If any selection have been changed by permit applicant an explanation should be included in Table E.
Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at
https://www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCl/
Yes
No
Form/Title
Field Inspector
Pass
Fail
❑ ❑
•
0
•
❑ ❑
NRCI-LTI-01-E - Must be submitted for all buildings
❑
❑
0
•
NRCI-LTI-02-E- Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), to be
❑
❑
recognized for compliance.
rl
•
NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a
❑
❑
multipurpose room or a theater to be recognized for compliance.
•
NRCI-LTI-05-E- Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance.
❑
❑
•
NRCI-LTI-06-E- Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance.
❑
❑
U. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE
Selections have been made based on information provided in this document. If any selection have been changed by the permit applicant, an explanation should be included in Table E.
Additional Remarks. These documents must be provided to the building inspector during construction and any with "-A" in the form name must be completed through an Acceptance
Test Technician Certification Provider (ATTCP). For more information visit: http://www. energy. ca.gov/title24/attcp/providers.html
Yes
No
Form/Title
Field Inspector
Pass Fail
•
0
NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls.
❑ ❑
•
0
NRCA-LTI-03-A - Must be submitted for automatic daylight controls.
❑ ❑
0
•
NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls.
❑ ❑
0
1 •
NRCA-LTI-05-A. - Must be submitted for institutional tuning power adjustment factor (PAF)
❑ ❑
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
This document is used to demonstrate compliance for mechanical systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive
path outlined in140.4 or §141.0(bl2 for alterations.
Project Name: Rapport - La Quinta Report Page: (Page 1 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
A. GENERAL INFORMATION
01
Project Location (city) La Quinta
04 Total Conditioned Floor Area 14416
02
Climate Zone 15
05
Total Unconditioned Floor Area 0
03
Occupancy Types Within Project:
06 # of Stories (Habitable Above Grade) 1
® Office (B) ® Retail (M)
®
Non -refrigerated Warehouse (S)
® Heating Air System
PHigh_H/ MotelGuest Rooms (R-1) ❑School (E)
❑Healthcare
Facility (I)
Air Economizer
Rise Residential (R -2/R-3) ❑ Relocatable Class Bldg (E)
®
Other (write in)
See Table J
B. PROJECT SCOPE
This table Includes mechanical systems or components that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in
140.4 or §141.0(bl2 for alterations.
01
02
03
Air System(s)
Wet System Components
Dry System Components
® Heating Air System
❑
Water Economizer
®
Air Economizer
® Cooling Air System
❑
Pumps
❑
Electric Resistance Heat
Mechanical Controls
❑
System Piping
®
Fan Systems
® Mechanical Controls (existing to remain, altered
or new)
❑
Cooling Towers
®
Ductwork (existing to remain, altered or new)
❑
Chillers
®
Ventilation
❑ Boilers
❑
Zonal Systems/ Terminal Boxes
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 2 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
C. COMPLIANCE RESULTS
Table C will indicate if the project data input into the compliance document is compliant with mechanical requirements. This table is not editable by the user. If this table says "DOES
NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D., or the table indicated as not compliant for guidance.
01
02
03
04
05
06
07
08
09
System
Fans/
System
Summary
AND
Pumps
AND
Economizers
AND
Controls
AND
Ventilation
AND
Terminal Box
AND
Distribution
AND
Cooling Towers
§110.1,§140.4(k)110.2
140.4 c ,
120.1
Controls
120.3
§110.2(e)2
Compliance Results
110.2,
140.4 e
§120.2
§140.4(d)
140.4
140.4 Uf
(See Table F)
(See Table G)
(See Table H)
(See Table 1)
(See Table J)
(See Table K)
(See Table L)
I
I (See Table M)
Yes
AND
AND
Yes
AND
Yes
AND
I Yes
AND
AND
Yes
AND
I
I COMPLIES
Mandatory Measures Compliance (See Table Q for Details)
COMPLIES
D. EXCEPTIONAL CONDITIONS
This table is auto filled with uneditable comments because of selections made or data entered in tables throughout the form.
E. ADDITIONAL REMARKS
This table includes remarks made by the permit applicant to the Authority Having Jurisdiction.
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 3 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS)
This table is used to demonstrate compliance for mechanical equipment with mandatory requirements found in 110.1 and 110.2 a and prescriptive requirements found in §140.4(a)
§140.4(b) and 140.4 k or §141.0(b)2 for alterations.
Dry System Equipment
Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters)
01
02
03
04
05
06
07
08
09
10
11
Equipment Sizing per Mechanical Schedule (kBtu/h)
140.4 (a&b)
Smallest Size
Heating Output2,3
Cooling Output2,3
Load Calculations 3,4
Name or Item
Equipment Category per
Equipment Type per Tables 110.2 /Title
Available'Total
Tag
Tables 110.2
20
§140.4(a)
Supp'
Sensible
Total
Sensible
per Design
Rated
Heating
Per Design
Rated
Heating
Cooling
(kBtu/h)
(kBtu/h)
Output
(kBtu/h)
(kBtu/h)
Load
Load
(kBtu/h)
(kBtu/h)
(kBtu/h)
AC -A, -B, -C,
Unitary Heat Pumps
Air-cooled, split (3 phase)
NA: Load
213.6
57
0
262.23
38.85
134.92
290.67
-D,-E,-F
Controls
AC-G, AC -H,
Unitary Heat Pumps
Air-cooled, split (3 phase)
NA: Load
106.8
57
0
124.94
38.85
43.31
125.87
AC -1
Controls
AC -J
Unitary Heat Pumps
Air-cooled, split (3 phase)
NA: Load
29.98
48
0
40.64
44.85
14.14
48.69
Controls
'FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per
§140.4(a). Healthcare facilities are excepted.
ZIt is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables.
31f equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank.
4 Authority Having Jurisdiction may ask for load calculations used for compliance per §140.4(b).
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 4 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS)
Dry System Equipment Efficiency (other than Package Terminal Air Conditioners (PTAC) and Package Terminal Heat Pumps (PTHP))
01
02
03 04 05 06
07 08 09
Fixed Enthalpy
Economizer
Heating Mode
Cooling Mode
Constant Volume
Name:
Minimum
Minimum
(m)
Name or Item
Size Category
Rating
04
Efficiency
06
07
Efficiency
Tag
(Btu/h)
Condition
Efficiency Unit
Required per
Design Efficiency
Efficiency Unit
Required per
Design Efficiency
Maximum Design Supply Airflow
HP Unite
( °F)
Tables 110.2 /
Item Tag
Tables 110.2 /
(CFM)
Device
Title 20
Title 20
AC -A, -B, -C,
<65,000
Device (CFM)
HSPF
8.2
9
SEER
13.0
14
-D, -E, -F
Total System Design Supply Airflow (CFM):
12000
Total System Design
4.5
Maximum System Fan
1.88
AC-G, AC -H, AC -1
<65,000
HSPF
8.2
9
SEER
13.0
14
AC -J
<65,000
HSPF
18.2
9
1 SEER
13.0
14
G. PUMPS
This section does not apply to this project.
H. FAN SYSTEMS & AIR ECONOMIZERS
This table is used to demonstrate compliance with prescriptive requirements found in §140.4(c) §140.4(e) and 4140.4(m) for fan systems. Fan systems serving only process loads are
exempt from these requirements and do not need to be included in Table H.
System
AC -A, -B, -C,
Economizer: 1
Fixed Enthalpy
Economizer
Designed per §140.4(e) and
System Fan Type:
Constant Volume
Name:
-D, -E, -F
Controls:
(m)
01
02
03
04
05
06
07
08
Fan Power Pressure Drop Adjustment - Table 140.4-B
Fan Name or
Fan Function
Qty
y
Maximum Design Supply Airflow
HP Unite
Design HP
g
Design Airflow through
Item Tag
(CFM)
Device
Device (CFM)
SF
Supply
6
12000
BHP
0.75
Total System Design Supply Airflow (CFM):
12000
Total System Design
4.5
Maximum System Fan
1.88
(B)HP:
Power (B)HP:
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 5 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
H. FAN SYSTEMS & AIR ECONOMIZERS
System
AC-G, AC -H, AC -1
Economizer: 1
Fixed Enthalpy
Economizer
Designed per §140.4(e) and
System Fan Type:
Constant Volume
Name:
Controls:
(m)
01
02
03
04
05
06
07
08
Fan Power Pressure Drop Adjustment - Table 140.4-B
Fan Name or
Fan Function
Qt y
Maximum Design Supply Airflow
HP Unitz
Design HP
g
Design Airflow through
Item Tag
(CFM)
Device
Device (CFM)
SF
Supply
3
6000
BHP
0.75
Total System Design Supply Airflow (CFM):
6000
Total System Design
2.25
Maximum System Fan
1.88
(B)HP:
Power (B)HP:
System
AC -J
Economizer: 1
NA: <=54 kBtu/h cooling
Economizer
Designed per §140.4(e) and
System Fan Type:
Constant Volume
Name:
Controls:
(m)
01
02
03
04
05
06
07
08
Fan Power Pressure Drop Adjustment - Table 140.4-B
Fan Name or
Fan Function
Qty
y
Maximum Design Supply Airflow
HP Unite
Design HP
g
Design Airflow through
Item Tag
(CFM)
Device
Device (CFM)
SF
Supply
1
1600
BHP
0.5
EF
Exhaust
2
0
BHP
0.03
Total System Design
Maximum System Fan
Total System Design Supply Airflow (CFM):
1600
0.56
1.5
(B)HP:
Power (B)HP:
1 FOOTNOTES: Computer room economizers must meet requirements of §140.9(a) and will be documented on the NRCC-PRC-E document.
Z The unit used for HP must be consistent for all fans within a system.
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 6 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
I. SYSTEM CONTROLS
This table is used to demonstrate compliance with mandatory controls in 110.2 and 120.2 and prescriptive controls in 140.4 and (n) or requirements in §141.0(b)2E for altered
space conditioning systems.
01
02
03
04
05
06
07
08
09
Conditioned
Thermostats
Shut -Off
Isolation
Supply Air
System Name
System
Floor Area
1
110.2 b & (c)
Controls
Zone
Demand Response
Temp. Reset
Window Interlocks per
Zoning
Being Served
,
§120.2(a)or §141.0(b)2E
§120.2(e)
Controls
1§ 10.12 and 120.2 b
§140.4(f)
§140.4(n)
(ft2)
§120.2(g)
NA: 7 day
AC -A, -B, -C,-D,-E,-F
Single zone
<= 25,000 ft2
Setback
per
4 Hour Timer
DR Tstat per 110.12
Included
NA: No operable windows
§120.2(e)1
NA: 7 day
AC-G, AC -H, AC -1
Single zone
<= 25,000 ft2
Setback
per
4 Hour Timer
DR Tstat per1§ 10.12
Included
NA: No operable windows
§120.2(e)1
NA: 7 day
AC -J
Single zone
<= 25,000 ft2
Setback
per
4 Hour Timer
DR Tstat per 110.12
Included
NA: No operable windows
§120.2(e)1
'FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non -central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to
have setback thermostats.
*Notes: Controls with a * require a note in the space below explaining how compliance is achieved. EX: system 1: SA Temp Reset: Exempt because zones compliant with §140.4(d);
EXCEPTION 1 to §140.4(f)
J. VENTILATION AND INDOOR AIR QUALITY
This table is used to demonstrate compliance with mandatory ventilation requirements in 120.1 and §120.2(e)3B for all nonresidential, high-rise residential and hotel/motel
occupancies. For alterations, only ventialtion systems being altered within the scope of the permit application need to be documented in this table. In lieu of this table, the required
outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented in a spreadsheet.
01
❑ Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table.
02
® Check this box if the project included Nonresidential or Hotel/Motel spaces
❑ Check this box if the project included new or altered high-rise residential dwelling units.
03
❑ Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per J12Q.1 c 2.
Nonresidential
and Hotel/ Motel Ventilation Systems
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 7 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
J. VENTILATION AND INDOOR AIR QUALITY
04
05
06
07
Air Filtration per 120.1 c and §141.0(b)2 z
System Design OA CFM
System Design
Provided per §120.1(c) (NR and
System Name
AC -A, -B, -C,-D,-E,-F
Airflow i
1626
Transfer Air CFM
0
Hotel/Motel))
08
09
10 11
12
13
14
15
16
Mechanical Ventilation Required
per §120.1(c)3
3
Exh. Vent per §120.1(c)4
Space Name
DCV or Sensor Controls per 4120.1(d)3,
Conditioned
# of Shower
Required
of item Tag
Occupancy Type
Floor Area
heads/
# of
Min OA
Required
Provided per Design
§120.1(d)5, and §120.1(e)3 6
(ft2)
toilets
peoples
CFM
Min CFM
CFM
Provided per
Occupiable storage rooms for dry
DCV
§120.1(d)4
Storage Area
materials
10837
1625.6
0
0
NA: Not required
Occ Sensor
space type
17
Total System Required Min OA CFM
1626
18
Ventilation for this System Complies?
Yes
04
05
06
07
Air Filtration per 120.1 c and §141.0(b)2 Z
System Design OA CFM
System Design
Provided per §120.1(c) (NR and
System Name
AC-G, AC -H, AC -1
622
Airflow 1
Transfer Air CFM
0
Hotel/Motel))
08
09
10 11 12
13
14
15
16
Mechanical Ventilation Required
per §120.1(c)3
3
Exh. Vent per §120.1(c)4
Space Name
DCV or Sensor Controls per 4120.1(d)3,
Conditioned
# of Shower
Required
of item Tag
Occupancy Type
Floor Area
heads/
# of
Min OA
Required
Provided per Design
§120.1(d)5, and §120.1(e)3 6
(ftz)
toilets
peoples
CFM
Min CFM
CFM
Provided per
DCV
§120.1(d)4
Showroom
Retail sales
2490
622.5
0
0
NA: Not required
Occ Sensor
space type
17
Total System Required Min OA CFM
622
18
Ventilation for this System Complies?
Yes
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 8 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
J. VENTILATION AND INDOOR AIR QUALITY
04
05
06
07
Air Filtration per 120.1 c and §141.0(b)2 z
System Design OA CFM
System Design
Provided per §120.1(c) (NR and
System Name
AC -J
Airflow i
45
Transfer Air CFM
0
Hotel/Motel))
08
09
10 11
12
13
14
15
16
Mechanical Ventilation Required
per §120.1(c)3
3
Exh. Vent per §120.1(c)4
Space Name
DCV or Sensor Controls per 4120.1(d)3,
Conditioned
# of Shower
Required
of item Tag
Occupancy Type
Floor Area
heads/
# of
Min OA
Required
Provided per Design
§120.1(d)5, and §120.1(e)3 6
(ft2)
toilets
peoples
CFM
Min CFM
CFM
DCV
NA: Not required per
§120.1(d)3
Loading
Office space
300
45
0
0
NA: Not required
Occ Sensor
spacetype
DCV
NA: Not required per
§120.1(d)3
RESTROOM
Toilet, private
389
0
0
100
NA: Not required
Occ Sensor
space type
17
Total System Required Min OA CFM
45
18
Ventilation for this System Complies?
Yes
1 FOOTNOTES: System CFM should include both mechanical and natural ventilation for the zone/system
2 Air filtration requirements apply to the following three system types per §120.101A : space conditioning systems utilizing ducts to supply air to occupiable space, supply -only
ventilation systems providing outside air to occupiable space, supply side of balanced ventilation systems including heat recovery and energy recovery ventilation systems providing
outside air to occupiable space.
3 Uniform Mechanical Code may have more stringent ventilation requirements; the most stringent code requirement takes precedence.
4 See Standards Tables 120.1-A and 120.1-B.
s For lecture halls with fixed seating, the expected number of occupants shall be shall be determined in accordance with the California Building Code.
6 §120.2(e)3 requires systems serving rooms that are required by 4130.1(c) to have lighting occupancy sensing controls to also have occupancy sensing zone controls for ventilation.
Examples of spaces which require lighting occupancy sensors include offices 250ft2 or smaller, multipurpose rooms less than 1,000 ft2, classrooms, conference rooms, restrooms, aisles
and open areas in warehouses, library book stack aisles, corridors, stairwells, parking garages, and loading and unloading zones, unless excepted by §130.1(c).
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 9 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
K. TERMINAL BOX CONTROLS
This section does not apply to this project.
L. DISTRIBUTION (DUCTWORK and PIPING)
This table is used to show compliance with mandatory pipe insulation requirements found in 120.3 and prescriptive requirements found in §140.4(l) for duct leakage testing.
Duct Leakage Sealing
The answers to the questions below apply to the following duct systems: AC -A, -B, -C,-D,-E,-F Duct leakage testing triggered for these systems? No
11 No
The scope of the project includes only duct systems serving healthcare facilities
12 Yes
Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space -conditioning system.
13 No
The space conditioning system serves less than 5,000 ftz of conditioned floor area.
14 No
The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system:
❑
Outdoors
❑
In a space directly under a roof that has a U -factor greater than the u -factor of the ceiling, or if the roof does not meet the
requirements of J140.3 a1113 or if the roof has fixed vents or openings to the outside/ unconditioned spaces
❑
In an unconditioned crawl space
❑
iln other unconditioned spaces
15
The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos.
16
The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification
and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2.
17
Yes
Duct system shall be sealed in acordance with the California Mechanical Code
The answers to the questions below apply to the following duct systems: IAC -G, AC -H, AC -1 Duct leakage testing triggered for these systems? No
11
No
The scope of the project includes only duct systems serving healthcare facilities
12
Yes
Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space -conditioning system.
13
Yes
The space conditioning system serves less than 5,000 ftz of conditioned floor area.
14
No
The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system:
❑
Outdoors
❑
In a space directly under a roof that has a U -factor greater than the u -factor of the ceiling, or if the roof does not meet the
requirements of §140.31a11B or if the roof has fixed vents or openings to the outside/ unconditioned spaces
❑
In an unconditioned crawl space
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 10 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
L. DISTRIBUTION (DUCTWORK and PIPING)
❑
In other unconditioned spaces
15
The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos.
16
The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification
and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2.
17
Yes
Duct system shall be sealed in acordance with the California Mechanical Code
The answers to the questions below apply to the following duct systems: AC -J IDuct leakage testing triggered for these systems? No
11 No
The scope of the project includes only duct systems serving healthcare facilities
12 Yes
Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space -conditioning system.
13 Yes
The space conditioning system serves less than 5,000 ft2 of conditioned floor area.
14 No
The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system:
❑
Outdoors
❑
In a space directly under a roof that has a LI -factor greater than the u -factor of the ceiling, or if the roof does not meet the
requirements of §140.3(a)113 or if the roof has fixed vents or openings to the outside/ unconditioned spaces
❑
In an unconditioned crawl space
❑
In other unconditioned spaces
15
The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos.
16
The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification
and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2.
17
Yes
Duct system shall be sealed in acordance with the California Mechanical Code
M. COOLING TOWERS
This section does not apply to this project.
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 11 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
N. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION
Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks.
These documents must be provided to the building inspector during construction and can be found online at
https.11www. energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential Documents/NRCl/
Yes
No
Form/Title
Field Inspector
Pass
Fail
•
Q
NRCI-MCH-01-E - Must be submitted for all buildings
❑
❑
O. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE
Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks.
These documents must be provided to the building inspector during construction and can be found online at
https.11www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCA/
Yes
No
Form/Title
Systems To Be Field Verified
Field Inspector
Pass
TFail
NRCA-MCH-02-A - Outdoor Air must be submitted for all newly installed HVAC units. Note:
•
O
MCH -02-A can be performed in conjunction with MCH -07-A Supply Fan VFD Acceptance (if
❑
❑
applicable) since testing activities overlap.
NRCA-MCH-03-A - Constant Volume Single Zone HVAC NOTE: This form does not automatically
•
O
move to "Yes'. If Constant Volume Single Zone HVAC Systems are included in the scope, permit
❑
❑
applicant should move this form to "Yes".
•
NRCA-MCH-04-A - Air Distribution Duct Leakage
❑
❑
•
O
NRCA-MCH-05-A - Air Economizer Controls
❑
❑
NRCA-MCH-06-A Demand Control Ventilation Systems must be submitted for all systems
•
O
required to employ demand controlled ventilation (refer to §120.1(c)3 ) can vary outside
❑
❑
ventilation flow rates based on maintaining interior carbon dioxide (CO2) concentration
setpoints.
O
•
NRCA-MCH-07-A Supply Fan Variable Flow Controls
❑
❑
O
•
NRCA-MCH-08-A Valve Leakage Test
❑
❑
O
•
NRCA-MCH-09-A Supply Water Temperature Reset Controls
❑
❑
O
•
NRCA-MCH-10-A Hydronic System Variable Flow Controls
❑
❑
•
0
INRCA-MCH-11-A Automatic Demand Shed Controls
❑
❑
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 12 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
O. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE
•
0
NRCA-MCH-12-A FDD for Packaged Direct Expansion Units
Form/Title Field Inspector
Pass Fail
❑
❑
0
•
NRCA-MCH-13-A Automatic FDD for Air Handling Units and Zone Terminal Units Acceptance
NRCV-MCH-24 Enclosure Air Leakaage Worksheet NOTE: Must be completed by a HERS Rater ❑ ❑
❑
❑
0
•
NRCA-MCH-14-A Distributed Energy Storage DX AC Systems Acceptance NOTE: This form does
not automatically move to "Yes". If Distributed Energy System DX AC Systems are included in teh
scope permit applicant should move this form to 'Yes".
NRCV-MCH-32 Local Mechanical Exhaust NOTE: Must be completed by a HERS Rater ❑ ❑
❑
❑
0
•
NRCA-MCH-15-A Thermal Energy Storage (TES) System Acceptance NOTE: This form does not
automatically move to "Yes". If Chilled water Storage, Ice -on -Coil Internal Melt, Ice -on -Coil
External melt, Ice Harvester, Brine, Ice -Slurry, Eutecti Salt, Clathrate Hydrate Slurry (CHS),
Cryogenic or Encapsulated (Ice Ball) Systems are included in the scope, permit applicant should
move this form to 'Yes".
❑
❑
•
0
NRCA-MCH-16-A Supply Air Temperature Reset Controls
❑
❑
0
•
NRCA-MCH-17-A Condenser Water Temperature Reset Controls
❑
❑
0
•
NRCA-MCH-18-A Energy Management Control Systems
❑
❑
•
NRCA-MCH-19-A Occupancy Sensor Controls
❑
❑
0
•
NRCA-MCH-20 Multi -Family Ventilation
❑
❑
0
•
NRCA-MCH-21 Multi -Family Envelope Leakage
❑
❑
P. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION
Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks.
These documents must be completed by a HERS Rater and provided to the building inspector during construction. The final documents must be created by a HERS Provider's registry, but
drafts can be found online at https://www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCV/
Yes
No
Form/Title Field Inspector
Pass Fail
0
•
NRCV-MCH-04-H Duct Leakaage Test NOTE: Must be completed by a HERS Rater ❑ ❑
0
•
NRCV-MCH-24 Enclosure Air Leakaage Worksheet NOTE: Must be completed by a HERS Rater ❑ ❑
0
•
NRCV-MCH-27 High-rise Resdential NOTE: Must be completed by a HERS Rater ❑ ❑
0
•
NRCV-MCH-32 Local Mechanical Exhaust NOTE: Must be completed by a HERS Rater ❑ ❑
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601
STATE OF CALIFORNIA
Mechanical Systems
NRCC-MCH-E
CALIFORNIA ENERGY COMMISSION
CERTIFICATE OF COMPLIANCE NRCC-MCH-E
Project Name: Rapport - La Quints Report Page: (Page 13 of 14)
Project Address: 44125 Jefferson St Date Prepared: 1/24/2022
Q. MANDATORY MEASURES DOCUMENTATION LOCATION
This table is used to indicate where mandatory measures are documented in the plan set or construction documentation.
01
02
Compliance with Mandatory Measures documented through MCH
Mandatory Measures Note Block
Yes
Plan sheet or construction document location
M -Sheets
Registration Number:
Registration Date/Time:
Registration Provider: Energysoft
CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43
Schema Version: rev 20200601