BCOM2021-0079 Title 24I BUILDING ENERGY ANALYSIS REPORT I PROJECT: Rapport - La Quinta 44125 Jefferson St La Qu i nta, CA 92253 Project Designer: 82410 Padova dr BCOM2021-0079 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE BY: A DATE: 0112712022 Indio, CA 92203 13,916SF RETAIL STORE (760) 774-3487 WITH STORAGE TI/VB/M, S-OCC/126-OL/SPRINKLED [RAPPORT RM FURNITURE] THIS PERMIT DOES NOT Report Prepared by: INCLUDE BUILDING SIGNAGE, STORAGE RACKS Arash Nazari OR PLUMBING A & N Design Group ALTERATIONS. TUMF AND 21550 Oxnard Street #300 DIF NOT ASSESSED BASED Woodland Hills, CA, CA 91367 ON NO CHANGE OF USE OR ADDITIONAL SQUARE 818-288-4361 FOOTAGE. 2019 CALIFORNIA BUILDING CODES. A & N DESIGN GROUP Job Number: 287 Date: 1/24/2022 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards. This program developed by EnergySoft Software — www.energysoft.com. I TABLE OF CONTENTS I Cover Page Table of Contents Form NRCC-LTI-E Indoor Lighting Form NRCC-MCH-E Mechanical Systems 2 3 10 STATE OF CALIFORNIA Indoor Lighting N RCC-LTI-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E This document is used to demonstrate compliance with requirements in 110.9 §110.12(c), 130.0 130.1 140.6 and §141.0(b)2 for indoor lighting scopes using the prescriptive path. Project Name: Rapport - La QuintaReport Page: (Page 1 of 7) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 A. GENERAL INFORMATION 01 Project Location (city) La Quinta 04 Total Conditioned Floor Area (ft2) 14,416 02 Climate Zone 15 05 Total Unconditioned Floor Area (ft2) 0 03 Occupancy Types Within Project (select all that apply): 06 # of Stories (Habitable Above Grade) 1 ® Office 10 IRetail 10 1warehouse ❑ Hotel/Motel ❑ School Areas ® Altered Lighting System n g Garage ❑ High -Rise Residential ElRelocatable ElHealthcare Tport ElOther (Write in)See Table I B. PROJECT SCOPE This table includes any lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in1§ 40.6 or §141.0(b)2 for alterations. Scope of Work Conditioned Spaces Unconditioned Spaces 01 02 03 04 05 My Project Consists of (check all that apply): Calculation Method Area (ft2) Calculation Method Area (ft2) ❑ New Lighting System ❑ New Lighting System - Parking Garage ® Altered Lighting System n Area Category Method 14416 Area Category Method 0 Total Area of Work (ft2) 14416 0 Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Indoor Lighting N RCC-LTI-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Rapport - La Quints Report Page: (Page 2 of 7) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 C. COMPLIANCE RESULTS If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance. Designed Wattage: Conditioned Spaces Allowed Lighting Power per §140.6 b (Watts) 02 Adjusted Lighting Power per §140.6(a) (Watts) 05 Compliance Results Lighting in 08 09 01 02 03 04 Small Aperture & 05 06 07 Excluded per 08 09 conditioned and Fail Tag Description (Track) Fixture Color Changer luminaireZ Area of Luminaires §140.6(a)3 Adjustments Lithonia JCBL-LED Damp No unconditioned 84 Mfr. Spec 33 No 2,772 ❑ ❑ Rated High Bay PAF LightingTotal spaces must not be Complete Area Category Tailored Total > Total Adjusted � combined forAllowed Building Category Additional§140.6(c)3 = Designed Control Credits = (Watts) Watts 05 must be >= 08 compliance per §140.6(c)1 §140.6(c)2 §140.6(c)2G ( +) (Watts) (Watts)4140.6(a)2 *Includes 140.6 §140.6(b)1 ( +) (-) Adjustments (See Table 1) (See Table I) (See Table J) (See Table K) (See Table F) (See Table P) Conditioned 8,109.5 0 = 8,110 >_ 7,744 0 = 7744 COMPLIES Unconditioned Controls Compliance (See Table H for Details) COMPLIES Rated Power Reduction Compliance (See Table Q for Details) D. EXCEPTIONAL CONDITIONS This table is auto filled with uneditable comments because of selections made or data entered in tables throughout the form. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. INDOOR LIGHTING FIXTURE SCHEDULE This table includes all permanent designed lighting and all portable lighting in offices. Designed Wattage: Conditioned Spaces 01 02 03 04 05 06 07 08 09 10 Name or Item Complete Luminaire Modular Small Aperture & Watts per How is Wattage Total Number Excluded per Design Watts Field Inspector Pass Fail Tag Description (Track) Fixture Color Changer luminaireZ determined of Luminaires §140.6(a)3 T1 Lithonia JCBL-LED Damp No No 84 Mfr. Spec 33 No 2,772 ❑ ❑ Rated High Bay Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Indoor Lighting N RCC-LTI-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Rapport - La Quints Report Page: (Page 3 of 7) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 F. INDOOR LIGHTING FIXTURE SCHEDULE T2 JUNO 351-170 Yes No 660 Mfr. Spec 7 No 4,620 ❑ ❑ T3 Lithonia LDN4 No No 32 Mfr. Spec 11 No 352 ❑ ❑ Total Designed Watts: CONDITIONED SPACES 7,744 'FOOTNOTE: Design Watts for small aperture and color changing luminaires which qualify per §140.6(a)4B is adjusted to be 75% of their rated wattage. Table F automatically makes this adjustment, the permit applicant should enter full rated wattage in column 05. ZAuthority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per 4130.0(c) Wattage used must be the maximum rated for the luminaire, not the lamp. G. MODULAR LIGHTING SYSTEMS This table includes lighting controls for conditioned and unconditioned spaces. When a control having a * is shown, the notes section of this table provides more detail on how compliance is achieved. The lighting controls section of the Compliance Summary Table on the first page will show "DOES NOT COMPLY" if the notes are left blank. Building Level Controls 01 02 03 This table calculates wattage for modular lighting systems/ track lighting fixtures indicated on Table F and transfers wattage to Table F. Field Inspector Pass I Fail 01 02 03 04 Name or Complete Track Description Calculation Method per §130.0(66 Track Item Tag Wattage iv Power supplied by T2 JUNO 351-170 ® i Installed Luminaires Elii Current Limiter ElPanel iii Overcurrent Protection Eldriver, power supply or vs Default 30 W/ft transformer' Rated Default Number of luminaires in Watts per Total Watts Linear ft of track or W/LF Total Watts system X luminaire - OR busway X 30 - 660 22 30 660 'FOOTNOTE: For power -over -Ethernet lighting systems, power provided to installed non -lighting devices may be subtracted from the total power rating of the power -over -Ethernet system. H. INDOOR LIGHTING CONTROLS (Not including PAFs) This table includes lighting controls for conditioned and unconditioned spaces. When a control having a * is shown, the notes section of this table provides more detail on how compliance is achieved. The lighting controls section of the Compliance Summary Table on the first page will show "DOES NOT COMPLY" if the notes are left blank. Building Level Controls 01 02 03 Mandatory Demand Response §110.12(c) Shut-off controls §130.1(c) Field Inspector Pass I Fail Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Indoor Lighting N RCC-LTI-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Rapport - La Quints Report Page: (Page 4 of 7) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 H. INDOOR LIGHTING CONTROLS (Not including PAFs) Not Required <= 10,000 SF Whole Building Auto Time Switch ❑ ❑ Area Level Controls 04 05 06 07 08 09 10 11 12 Allowed Wattage (Watts) Additional Allowance / Adjustment Area Category PAF Storage Area Commercial Industrial Storage Area Primary/SkySecondary 10,837 4,876.7 No No Complete Building or Area Area Controls Multi -Level Shut -Off Controls lit Interlocked Field Inspector Area Description Category Primary Function 130. 1 a Controls 130.1 c Daylighting Daylighting Systems Area §130.1(b) §130.1(d) §140.6(d) §140.6(a)1 Pass Fail RESTROOM Restrooms ManualS Manual Dimmer Occupancy Sensor N/A N/A No ❑ ❑ Offices Office 250 square feet or less Manual Manual Dimmer Occupancy Sensor Included Included No ❑ ❑ Sales Area All Other Space Types Manual Manual Dimmer Occupancy Sensor Included Included No ❑ ❑ Furniture Storage Warehouse Manual ManualDimmer Occupancy Sensor Included Included No El El Breakroom Office 250 square feet or less Manual ManualDimmer Occupancy Sensor N/A N/A I No ❑ON/OFF El *NOTES: Controls with a * require a note in the space below explaining how compliance is achieved. 13 EX: Conference 1: Primary/Skylight Daylighting: Exempt because less than 120 watts of general lighting; EXCEPTION 1 to §119.1(d)2 Plan Sheet Showing Daylit Zones: I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS Each area complying using the Complete Building or Area Category Methods per §140.6(b) are included in this table. Column 06 indicates if additional lighting power allowances per §140.6(c) or adjustments per 114Q.6LaI are being used. Conditioned Spaces 01 02 03 04 05 06 Area Description Complete Building or Area Category Primary Function Area Allowed Density (W/ftZ ) Area (ft Z) Allowed Wattage (Watts) Additional Allowance / Adjustment Area Category PAF Storage Area Commercial Industrial Storage Area 0.45 10,837 4,876.7 No No Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Indoor Lighting NRCC-LTI-E CALIFORNIA ENERGY COMMISSION 'ERTIFICATE OF COMPLIANCE NRCC-LTI-1 3roject Name: Rapport - La Quinta Report Page: (Page 5 of 7 3roject Address: 44125 Jefferson St Date Prepared: 1/24/202: I. LIGHTING POWER ALLOWANCE: COMPLETE BUILDING OR AREA CATEGORY METHODS Showroom Retail Merchandise Sales 1 2,490 2,490 No No Loading Office 250 square feet or less 0.7 300 210 No No RESTROOM Restrooms 0.65 389 252.8 No No OFFICE & BREAI<ROOM Office 250 square feet or less 0.7 400 280 No No TOTALS: 14,416 8,109.5 See Tables J, or P for detail I. ADDITIONAL ALLOWANCE: AREA CATEGORY METHOD QUALIFYING LIGHTING SYSTEM -his section does not apply to this project. <. TAILORED METHOD GENERAL LIGHTING POWER ALLOWANCE -his section does not apply to this project. _. ADDITIONAL LIGHTING ALLOWANCE: TAILORED WALL DISPLAY -his section does not apply to this project. VI. ADDITIONAL LIGHTING ALLOWANCE: TAILORED FLOOR AND TASK LIGHTING Fhis section does not apply to this project. V. ADDITIONAL LIGHTING ALLOWANCE: TAILORED ORNAMENTAL/SPECIAL EFFECTS Fhis section does not apply to this project. 3. ADDITIONAL LIGHTING ALLOWANCE: TAILORED VERY VALUABLE MERCHANDISE Fhis section does not apply to this project. :. POWER ADJUSTMENT: LIGHTING CONTROL CREDIT (POWER ADJUSTMENT FACTOR (PAF)) -his section does not apply to this project. :1. RATED POWER REDUCTION COMPLIANCE FOR ALTERATIONS Fhis section does not apply to this project. Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Indoor Lighting N RCC-LTI-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-E Project Name: Rapport - La Quints Report Page: (Page 6 of 7] Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 R. 80% LIGHTING POWER FOR ALL ALTERATIONS - CONTROLS EXCEPTIONS This section does not apply to this project. S. DAYLIGHT DESIGN POWER ADJUSTMENT FACTOR (PAF) This section does not apply to this project. T. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in this document. If any selection have been changed by permit applicant an explanation should be included in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCl/ Yes No Form/Title Field Inspector Pass Fail ❑ ❑ • 0 • ❑ ❑ NRCI-LTI-01-E - Must be submitted for all buildings ❑ ❑ 0 • NRCI-LTI-02-E- Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), to be ❑ ❑ recognized for compliance. rl • NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a ❑ ❑ multipurpose room or a theater to be recognized for compliance. • NRCI-LTI-05-E- Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. ❑ ❑ • NRCI-LTI-06-E- Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. ❑ ❑ U. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Selections have been made based on information provided in this document. If any selection have been changed by the permit applicant, an explanation should be included in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and any with "-A" in the form name must be completed through an Acceptance Test Technician Certification Provider (ATTCP). For more information visit: http://www. energy. ca.gov/title24/attcp/providers.html Yes No Form/Title Field Inspector Pass Fail • 0 NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. ❑ ❑ • 0 NRCA-LTI-03-A - Must be submitted for automatic daylight controls. ❑ ❑ 0 • NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls. ❑ ❑ 0 1 • NRCA-LTI-05-A. - Must be submitted for institutional tuning power adjustment factor (PAF) ❑ ❑ Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E This document is used to demonstrate compliance for mechanical systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in140.4 or §141.0(bl2 for alterations. Project Name: Rapport - La Quinta Report Page: (Page 1 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 A. GENERAL INFORMATION 01 Project Location (city) La Quinta 04 Total Conditioned Floor Area 14416 02 Climate Zone 15 05 Total Unconditioned Floor Area 0 03 Occupancy Types Within Project: 06 # of Stories (Habitable Above Grade) 1 ® Office (B) ® Retail (M) ® Non -refrigerated Warehouse (S) ® Heating Air System PHigh_H/ MotelGuest Rooms (R-1) ❑School (E) ❑Healthcare Facility (I) Air Economizer Rise Residential (R -2/R-3) ❑ Relocatable Class Bldg (E) ® Other (write in) See Table J B. PROJECT SCOPE This table Includes mechanical systems or components that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.4 or §141.0(bl2 for alterations. 01 02 03 Air System(s) Wet System Components Dry System Components ® Heating Air System ❑ Water Economizer ® Air Economizer ® Cooling Air System ❑ Pumps ❑ Electric Resistance Heat Mechanical Controls ❑ System Piping ® Fan Systems ® Mechanical Controls (existing to remain, altered or new) ❑ Cooling Towers ® Ductwork (existing to remain, altered or new) ❑ Chillers ® Ventilation ❑ Boilers ❑ Zonal Systems/ Terminal Boxes Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 2 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 C. COMPLIANCE RESULTS Table C will indicate if the project data input into the compliance document is compliant with mechanical requirements. This table is not editable by the user. If this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D., or the table indicated as not compliant for guidance. 01 02 03 04 05 06 07 08 09 System Fans/ System Summary AND Pumps AND Economizers AND Controls AND Ventilation AND Terminal Box AND Distribution AND Cooling Towers §110.1,§140.4(k)110.2 140.4 c , 120.1 Controls 120.3 §110.2(e)2 Compliance Results 110.2, 140.4 e §120.2 §140.4(d) 140.4 140.4 Uf (See Table F) (See Table G) (See Table H) (See Table 1) (See Table J) (See Table K) (See Table L) I I (See Table M) Yes AND AND Yes AND Yes AND I Yes AND AND Yes AND I I COMPLIES Mandatory Measures Compliance (See Table Q for Details) COMPLIES D. EXCEPTIONAL CONDITIONS This table is auto filled with uneditable comments because of selections made or data entered in tables throughout the form. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 3 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) This table is used to demonstrate compliance for mechanical equipment with mandatory requirements found in 110.1 and 110.2 a and prescriptive requirements found in §140.4(a) §140.4(b) and 140.4 k or §141.0(b)2 for alterations. Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters) 01 02 03 04 05 06 07 08 09 10 11 Equipment Sizing per Mechanical Schedule (kBtu/h) 140.4 (a&b) Smallest Size Heating Output2,3 Cooling Output2,3 Load Calculations 3,4 Name or Item Equipment Category per Equipment Type per Tables 110.2 /Title Available'Total Tag Tables 110.2 20 §140.4(a) Supp' Sensible Total Sensible per Design Rated Heating Per Design Rated Heating Cooling (kBtu/h) (kBtu/h) Output (kBtu/h) (kBtu/h) Load Load (kBtu/h) (kBtu/h) (kBtu/h) AC -A, -B, -C, Unitary Heat Pumps Air-cooled, split (3 phase) NA: Load 213.6 57 0 262.23 38.85 134.92 290.67 -D,-E,-F Controls AC-G, AC -H, Unitary Heat Pumps Air-cooled, split (3 phase) NA: Load 106.8 57 0 124.94 38.85 43.31 125.87 AC -1 Controls AC -J Unitary Heat Pumps Air-cooled, split (3 phase) NA: Load 29.98 48 0 40.64 44.85 14.14 48.69 Controls 'FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per §140.4(a). Healthcare facilities are excepted. ZIt is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables. 31f equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank. 4 Authority Having Jurisdiction may ask for load calculations used for compliance per §140.4(b). Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 4 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) Dry System Equipment Efficiency (other than Package Terminal Air Conditioners (PTAC) and Package Terminal Heat Pumps (PTHP)) 01 02 03 04 05 06 07 08 09 Fixed Enthalpy Economizer Heating Mode Cooling Mode Constant Volume Name: Minimum Minimum (m) Name or Item Size Category Rating 04 Efficiency 06 07 Efficiency Tag (Btu/h) Condition Efficiency Unit Required per Design Efficiency Efficiency Unit Required per Design Efficiency Maximum Design Supply Airflow HP Unite ( °F) Tables 110.2 / Item Tag Tables 110.2 / (CFM) Device Title 20 Title 20 AC -A, -B, -C, <65,000 Device (CFM) HSPF 8.2 9 SEER 13.0 14 -D, -E, -F Total System Design Supply Airflow (CFM): 12000 Total System Design 4.5 Maximum System Fan 1.88 AC-G, AC -H, AC -1 <65,000 HSPF 8.2 9 SEER 13.0 14 AC -J <65,000 HSPF 18.2 9 1 SEER 13.0 14 G. PUMPS This section does not apply to this project. H. FAN SYSTEMS & AIR ECONOMIZERS This table is used to demonstrate compliance with prescriptive requirements found in §140.4(c) §140.4(e) and 4140.4(m) for fan systems. Fan systems serving only process loads are exempt from these requirements and do not need to be included in Table H. System AC -A, -B, -C, Economizer: 1 Fixed Enthalpy Economizer Designed per §140.4(e) and System Fan Type: Constant Volume Name: -D, -E, -F Controls: (m) 01 02 03 04 05 06 07 08 Fan Power Pressure Drop Adjustment - Table 140.4-B Fan Name or Fan Function Qty y Maximum Design Supply Airflow HP Unite Design HP g Design Airflow through Item Tag (CFM) Device Device (CFM) SF Supply 6 12000 BHP 0.75 Total System Design Supply Airflow (CFM): 12000 Total System Design 4.5 Maximum System Fan 1.88 (B)HP: Power (B)HP: Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 5 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 H. FAN SYSTEMS & AIR ECONOMIZERS System AC-G, AC -H, AC -1 Economizer: 1 Fixed Enthalpy Economizer Designed per §140.4(e) and System Fan Type: Constant Volume Name: Controls: (m) 01 02 03 04 05 06 07 08 Fan Power Pressure Drop Adjustment - Table 140.4-B Fan Name or Fan Function Qt y Maximum Design Supply Airflow HP Unitz Design HP g Design Airflow through Item Tag (CFM) Device Device (CFM) SF Supply 3 6000 BHP 0.75 Total System Design Supply Airflow (CFM): 6000 Total System Design 2.25 Maximum System Fan 1.88 (B)HP: Power (B)HP: System AC -J Economizer: 1 NA: <=54 kBtu/h cooling Economizer Designed per §140.4(e) and System Fan Type: Constant Volume Name: Controls: (m) 01 02 03 04 05 06 07 08 Fan Power Pressure Drop Adjustment - Table 140.4-B Fan Name or Fan Function Qty y Maximum Design Supply Airflow HP Unite Design HP g Design Airflow through Item Tag (CFM) Device Device (CFM) SF Supply 1 1600 BHP 0.5 EF Exhaust 2 0 BHP 0.03 Total System Design Maximum System Fan Total System Design Supply Airflow (CFM): 1600 0.56 1.5 (B)HP: Power (B)HP: 1 FOOTNOTES: Computer room economizers must meet requirements of §140.9(a) and will be documented on the NRCC-PRC-E document. Z The unit used for HP must be consistent for all fans within a system. Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 6 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 I. SYSTEM CONTROLS This table is used to demonstrate compliance with mandatory controls in 110.2 and 120.2 and prescriptive controls in 140.4 and (n) or requirements in §141.0(b)2E for altered space conditioning systems. 01 02 03 04 05 06 07 08 09 Conditioned Thermostats Shut -Off Isolation Supply Air System Name System Floor Area 1 110.2 b & (c) Controls Zone Demand Response Temp. Reset Window Interlocks per Zoning Being Served , §120.2(a)or §141.0(b)2E §120.2(e) Controls 1§ 10.12 and 120.2 b §140.4(f) §140.4(n) (ft2) §120.2(g) NA: 7 day AC -A, -B, -C,-D,-E,-F Single zone <= 25,000 ft2 Setback per 4 Hour Timer DR Tstat per 110.12 Included NA: No operable windows §120.2(e)1 NA: 7 day AC-G, AC -H, AC -1 Single zone <= 25,000 ft2 Setback per 4 Hour Timer DR Tstat per1§ 10.12 Included NA: No operable windows §120.2(e)1 NA: 7 day AC -J Single zone <= 25,000 ft2 Setback per 4 Hour Timer DR Tstat per 110.12 Included NA: No operable windows §120.2(e)1 'FOOTNOTES: Gravity gas wall heaters, gravity floor heaters, gravity room heaters, non -central electric heaters, fireplaces or decorative gas appliances, wood stoves are not required to have setback thermostats. *Notes: Controls with a * require a note in the space below explaining how compliance is achieved. EX: system 1: SA Temp Reset: Exempt because zones compliant with §140.4(d); EXCEPTION 1 to §140.4(f) J. VENTILATION AND INDOOR AIR QUALITY This table is used to demonstrate compliance with mandatory ventilation requirements in 120.1 and §120.2(e)3B for all nonresidential, high-rise residential and hotel/motel occupancies. For alterations, only ventialtion systems being altered within the scope of the permit application need to be documented in this table. In lieu of this table, the required outdoor ventilation rates and airflows may be shown on the plans or the calculations can be presented in a spreadsheet. 01 ❑ Check the box if the project is showing ventilation calculations on the plans, or attaching the calculations instead of completing this table. 02 ® Check this box if the project included Nonresidential or Hotel/Motel spaces ❑ Check this box if the project included new or altered high-rise residential dwelling units. 03 ❑ Check the box if the project is using natural ventilation in any nonresidential or hotel/motel spaces to meet required ventilation rates per J12Q.1 c 2. Nonresidential and Hotel/ Motel Ventilation Systems Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 7 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 J. VENTILATION AND INDOOR AIR QUALITY 04 05 06 07 Air Filtration per 120.1 c and §141.0(b)2 z System Design OA CFM System Design Provided per §120.1(c) (NR and System Name AC -A, -B, -C,-D,-E,-F Airflow i 1626 Transfer Air CFM 0 Hotel/Motel)) 08 09 10 11 12 13 14 15 16 Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4 Space Name DCV or Sensor Controls per 4120.1(d)3, Conditioned # of Shower Required of item Tag Occupancy Type Floor Area heads/ # of Min OA Required Provided per Design §120.1(d)5, and §120.1(e)3 6 (ft2) toilets peoples CFM Min CFM CFM Provided per Occupiable storage rooms for dry DCV §120.1(d)4 Storage Area materials 10837 1625.6 0 0 NA: Not required Occ Sensor space type 17 Total System Required Min OA CFM 1626 18 Ventilation for this System Complies? Yes 04 05 06 07 Air Filtration per 120.1 c and §141.0(b)2 Z System Design OA CFM System Design Provided per §120.1(c) (NR and System Name AC-G, AC -H, AC -1 622 Airflow 1 Transfer Air CFM 0 Hotel/Motel)) 08 09 10 11 12 13 14 15 16 Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4 Space Name DCV or Sensor Controls per 4120.1(d)3, Conditioned # of Shower Required of item Tag Occupancy Type Floor Area heads/ # of Min OA Required Provided per Design §120.1(d)5, and §120.1(e)3 6 (ftz) toilets peoples CFM Min CFM CFM Provided per DCV §120.1(d)4 Showroom Retail sales 2490 622.5 0 0 NA: Not required Occ Sensor space type 17 Total System Required Min OA CFM 622 18 Ventilation for this System Complies? Yes Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 8 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 J. VENTILATION AND INDOOR AIR QUALITY 04 05 06 07 Air Filtration per 120.1 c and §141.0(b)2 z System Design OA CFM System Design Provided per §120.1(c) (NR and System Name AC -J Airflow i 45 Transfer Air CFM 0 Hotel/Motel)) 08 09 10 11 12 13 14 15 16 Mechanical Ventilation Required per §120.1(c)3 3 Exh. Vent per §120.1(c)4 Space Name DCV or Sensor Controls per 4120.1(d)3, Conditioned # of Shower Required of item Tag Occupancy Type Floor Area heads/ # of Min OA Required Provided per Design §120.1(d)5, and §120.1(e)3 6 (ft2) toilets peoples CFM Min CFM CFM DCV NA: Not required per §120.1(d)3 Loading Office space 300 45 0 0 NA: Not required Occ Sensor spacetype DCV NA: Not required per §120.1(d)3 RESTROOM Toilet, private 389 0 0 100 NA: Not required Occ Sensor space type 17 Total System Required Min OA CFM 45 18 Ventilation for this System Complies? Yes 1 FOOTNOTES: System CFM should include both mechanical and natural ventilation for the zone/system 2 Air filtration requirements apply to the following three system types per §120.101A : space conditioning systems utilizing ducts to supply air to occupiable space, supply -only ventilation systems providing outside air to occupiable space, supply side of balanced ventilation systems including heat recovery and energy recovery ventilation systems providing outside air to occupiable space. 3 Uniform Mechanical Code may have more stringent ventilation requirements; the most stringent code requirement takes precedence. 4 See Standards Tables 120.1-A and 120.1-B. s For lecture halls with fixed seating, the expected number of occupants shall be shall be determined in accordance with the California Building Code. 6 §120.2(e)3 requires systems serving rooms that are required by 4130.1(c) to have lighting occupancy sensing controls to also have occupancy sensing zone controls for ventilation. Examples of spaces which require lighting occupancy sensors include offices 250ft2 or smaller, multipurpose rooms less than 1,000 ft2, classrooms, conference rooms, restrooms, aisles and open areas in warehouses, library book stack aisles, corridors, stairwells, parking garages, and loading and unloading zones, unless excepted by §130.1(c). Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 9 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 K. TERMINAL BOX CONTROLS This section does not apply to this project. L. DISTRIBUTION (DUCTWORK and PIPING) This table is used to show compliance with mandatory pipe insulation requirements found in 120.3 and prescriptive requirements found in §140.4(l) for duct leakage testing. Duct Leakage Sealing The answers to the questions below apply to the following duct systems: AC -A, -B, -C,-D,-E,-F Duct leakage testing triggered for these systems? No 11 No The scope of the project includes only duct systems serving healthcare facilities 12 Yes Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space -conditioning system. 13 No The space conditioning system serves less than 5,000 ftz of conditioned floor area. 14 No The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system: ❑ Outdoors ❑ In a space directly under a roof that has a U -factor greater than the u -factor of the ceiling, or if the roof does not meet the requirements of J140.3 a1113 or if the roof has fixed vents or openings to the outside/ unconditioned spaces ❑ In an unconditioned crawl space ❑ iln other unconditioned spaces 15 The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes Duct system shall be sealed in acordance with the California Mechanical Code The answers to the questions below apply to the following duct systems: IAC -G, AC -H, AC -1 Duct leakage testing triggered for these systems? No 11 No The scope of the project includes only duct systems serving healthcare facilities 12 Yes Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space -conditioning system. 13 Yes The space conditioning system serves less than 5,000 ftz of conditioned floor area. 14 No The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system: ❑ Outdoors ❑ In a space directly under a roof that has a U -factor greater than the u -factor of the ceiling, or if the roof does not meet the requirements of §140.31a11B or if the roof has fixed vents or openings to the outside/ unconditioned spaces ❑ In an unconditioned crawl space Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 10 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 L. DISTRIBUTION (DUCTWORK and PIPING) ❑ In other unconditioned spaces 15 The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes Duct system shall be sealed in acordance with the California Mechanical Code The answers to the questions below apply to the following duct systems: AC -J IDuct leakage testing triggered for these systems? No 11 No The scope of the project includes only duct systems serving healthcare facilities 12 Yes Duct system provides conditioned air to an occupiable space for a constant volume, single zone, space -conditioning system. 13 Yes The space conditioning system serves less than 5,000 ft2 of conditioned floor area. 14 No The combined surface area of the ducts in the following locations is more than 25% of the total surface area of the entire duct system: ❑ Outdoors ❑ In a space directly under a roof that has a LI -factor greater than the u -factor of the ceiling, or if the roof does not meet the requirements of §140.3(a)113 or if the roof has fixed vents or openings to the outside/ unconditioned spaces ❑ In an unconditioned crawl space ❑ In other unconditioned spaces 15 The scope of the project includes extending an existing duct system, which is constructed, insulated or sealed with asbestos. 16 The scope of the project includes an existing duct system that is documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in the Reference Nonresidential Appendix NA2. 17 Yes Duct system shall be sealed in acordance with the California Mechanical Code M. COOLING TOWERS This section does not apply to this project. Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 11 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 N. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https.11www. energy.ca.gov/title24/2019standards/2019_compliance_documents/Nonresidential Documents/NRCl/ Yes No Form/Title Field Inspector Pass Fail • Q NRCI-MCH-01-E - Must be submitted for all buildings ❑ ❑ O. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https.11www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCA/ Yes No Form/Title Systems To Be Field Verified Field Inspector Pass TFail NRCA-MCH-02-A - Outdoor Air must be submitted for all newly installed HVAC units. Note: • O MCH -02-A can be performed in conjunction with MCH -07-A Supply Fan VFD Acceptance (if ❑ ❑ applicable) since testing activities overlap. NRCA-MCH-03-A - Constant Volume Single Zone HVAC NOTE: This form does not automatically • O move to "Yes'. If Constant Volume Single Zone HVAC Systems are included in the scope, permit ❑ ❑ applicant should move this form to "Yes". • NRCA-MCH-04-A - Air Distribution Duct Leakage ❑ ❑ • O NRCA-MCH-05-A - Air Economizer Controls ❑ ❑ NRCA-MCH-06-A Demand Control Ventilation Systems must be submitted for all systems • O required to employ demand controlled ventilation (refer to §120.1(c)3 ) can vary outside ❑ ❑ ventilation flow rates based on maintaining interior carbon dioxide (CO2) concentration setpoints. O • NRCA-MCH-07-A Supply Fan Variable Flow Controls ❑ ❑ O • NRCA-MCH-08-A Valve Leakage Test ❑ ❑ O • NRCA-MCH-09-A Supply Water Temperature Reset Controls ❑ ❑ O • NRCA-MCH-10-A Hydronic System Variable Flow Controls ❑ ❑ • 0 INRCA-MCH-11-A Automatic Demand Shed Controls ❑ ❑ Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 12 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 O. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE • 0 NRCA-MCH-12-A FDD for Packaged Direct Expansion Units Form/Title Field Inspector Pass Fail ❑ ❑ 0 • NRCA-MCH-13-A Automatic FDD for Air Handling Units and Zone Terminal Units Acceptance NRCV-MCH-24 Enclosure Air Leakaage Worksheet NOTE: Must be completed by a HERS Rater ❑ ❑ ❑ ❑ 0 • NRCA-MCH-14-A Distributed Energy Storage DX AC Systems Acceptance NOTE: This form does not automatically move to "Yes". If Distributed Energy System DX AC Systems are included in teh scope permit applicant should move this form to 'Yes". NRCV-MCH-32 Local Mechanical Exhaust NOTE: Must be completed by a HERS Rater ❑ ❑ ❑ ❑ 0 • NRCA-MCH-15-A Thermal Energy Storage (TES) System Acceptance NOTE: This form does not automatically move to "Yes". If Chilled water Storage, Ice -on -Coil Internal Melt, Ice -on -Coil External melt, Ice Harvester, Brine, Ice -Slurry, Eutecti Salt, Clathrate Hydrate Slurry (CHS), Cryogenic or Encapsulated (Ice Ball) Systems are included in the scope, permit applicant should move this form to 'Yes". ❑ ❑ • 0 NRCA-MCH-16-A Supply Air Temperature Reset Controls ❑ ❑ 0 • NRCA-MCH-17-A Condenser Water Temperature Reset Controls ❑ ❑ 0 • NRCA-MCH-18-A Energy Management Control Systems ❑ ❑ • NRCA-MCH-19-A Occupancy Sensor Controls ❑ ❑ 0 • NRCA-MCH-20 Multi -Family Ventilation ❑ ❑ 0 • NRCA-MCH-21 Multi -Family Envelope Leakage ❑ ❑ P. DECLARATION OF REQUIRED CERTIFICATES OF VERIFICATION Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E Additional Remarks. These documents must be completed by a HERS Rater and provided to the building inspector during construction. The final documents must be created by a HERS Provider's registry, but drafts can be found online at https://www.energy.ca.gov/title24/2019standards/2019 compliance documents/Nonresidential Documents/NRCV/ Yes No Form/Title Field Inspector Pass Fail 0 • NRCV-MCH-04-H Duct Leakaage Test NOTE: Must be completed by a HERS Rater ❑ ❑ 0 • NRCV-MCH-24 Enclosure Air Leakaage Worksheet NOTE: Must be completed by a HERS Rater ❑ ❑ 0 • NRCV-MCH-27 High-rise Resdential NOTE: Must be completed by a HERS Rater ❑ ❑ 0 • NRCV-MCH-32 Local Mechanical Exhaust NOTE: Must be completed by a HERS Rater ❑ ❑ Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601 STATE OF CALIFORNIA Mechanical Systems NRCC-MCH-E CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-MCH-E Project Name: Rapport - La Quints Report Page: (Page 13 of 14) Project Address: 44125 Jefferson St Date Prepared: 1/24/2022 Q. MANDATORY MEASURES DOCUMENTATION LOCATION This table is used to indicate where mandatory measures are documented in the plan set or construction documentation. 01 02 Compliance with Mandatory Measures documented through MCH Mandatory Measures Note Block Yes Plan sheet or construction document location M -Sheets Registration Number: Registration Date/Time: Registration Provider: Energysoft CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance Report Version: 2019.1.003 Report Generated: 2022-01-24 09:30:43 Schema Version: rev 20200601