Loading...
04-5066 (SFD) Title 24F rA I TITLE 24 REPORT Title 24 Report for: Sibert Residence 77-225 Avenida Arteaga La Quinta, CA CITY OF LA QUANTA BUILDING & SAFETY DEPT. APPROVE 1 ro' ct Designer: FOR CONST UCTI 9 DATE Q 113 04 g Report Prepared By: Joan D. Hacker. Insu-Form Inc. 68255 Corta Road Cathedral City, CA 92234 (760) 324-0216 Job Number: Date: 8i24i2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400. EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 77*425 HuE 01"FRGA FF1 kc F TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Checklist Form C -2R Computer Method Summary HVAC System Heating and Cooling Loads Summary Room Load Summary 1 2 3 8 10 16 20 EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 1 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Sibert Residence 8/24/2004 Project Title Date 77-225 Avenida Arteapa La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,410 ft2 Average Ceiling Height: 10.2 ft Total Conditioned Slab Area: 3,021 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northwest) 315 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ❑ Raised Floor Component Tvpe Const. Frame Assembly Location/Comments Type U -Value (attic, garage, typical, etc.) R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front (Northwest) 81.0 0.58 0.38 Bug Screen X❑ ❑ ❑ X❑ Left (Northeast) 124.0 0.58 0.38 Bug Screen X❑ ❑ ❑ X❑ Rear (Southeast) 32.0 0.58 0.38 Bug Screen X❑ ❑ ❑ x❑ Right (Southwest) 72.0 0.55 0.38 Bug Screen X❑ ❑ ❑ x❑ Right (Southwest) 136.0 0.58 0.38 Bug Screen X❑ ❑ ❑ X❑ Front (Northwest) 72.0 0.60 0.38 Bug Screen[i] ❑ ❑ X❑ Front (Northwest) 80.0 0.55 0.38 Bug Screen x❑ ❑ ❑X❑ Front (North) 15.0 0.58 0.38 Bug Screen X❑ ❑ ❑ X❑ Front (North) 9.0 0.60 0.38 Bug Screen X❑ ❑ ❑ X❑ Left (Northeast) 26.5 0.60 0.38 Bug Screen X❑ ❑ ❑ X❑ Rear (Southeast) 216.0 0.55 0.38 Bug Screen X❑ ❑ ❑ X❑ Rear (Southeast) 89.9 0.60 0.38 Bug Screen X❑ ❑ ❑ x❑ Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 E nergyPro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:3 of 23 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Sibert Residence . 8/24/2004 Project Title Date 77-225 Avenida Arteaga La Quinta Project Address Building Permit # Insu-Form Inc. (760) 324-0216 Plan Check / Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,410 ft2 Average Ceiling Height: 10.2 ft Total Conditioned Slab Area: 3,021 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: (Northwest) 315 deg Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 2 ❑ Raised Floor BUILDING SHELL INSULATION Const. Component Frame Assembly Location/Comments Type Type U -Value (attic, garage, typical, etc.) FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shadinq Yes / No Yes / No Right (Southwest) 92.3 0.60 0.38 Bug Screen X❑ ❑ ❑ 0 Right (West) 15.0 0.58 0.38 Bug Screen 0 ❑ ❑ 0 Right (West) 9.0 0.60 0.38 Bug Screen 0 El El 0 Left (East) 48.0 0.58 0.38 Bug Screen X❑ ❑ ❑ X❑ Left (East) 17.5 0.60 0.38 Bug Screen X❑ ❑ ❑ X❑ Rear (Southeast) 48.0 0.58 0.38 Roll -down Awning_ 0 ❑ ❑ 0 Rear (South) 17.5 0.60 0.38 Bug Screen 0 ❑ ❑X❑ Rear (South) 48.0 0.58 0.38 Bug Screen 0 ❑ ❑ o Skylight 17.0 0.45 0.45 None ❑ X❑ ❑X❑ Left (Northeast) 48.0 0.55 0.38 Bug ScreenX❑ ❑ ❑ 0 1:1 El ❑❑ 1:1 1:1 ❑❑ Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 Ener Pro 3.1 By Ener Soft User Number: 2655 Job Number: Pa e:4 of 23 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Sibert Residence 8/24/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Tank Distribution External Water Heater Water Heater Distribution # in Input Heating Equipment Minimum Type and Duct or System Name Type Type Syst. Btu/hr Type (furnace, heat, Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type Comments r:entral Furnace 80°% AFUE Ducts in Attic 4.2 Setback Second Floor Central Furnace Central F urna . 80°% AFUE Ducts in Attic 80°% AFUE Ducts in Attic 42 4.2 Setback Setback lone 1 Zone 3 (ventral Furnace 80°% AFUE Ducts in Attic 4.2 Setback Zone 2 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 42 sethack SPrnnd Flnnr Split Air Conditioner 12 0 SEER Ducts in Attic 4_7 Setback 7nne 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 3 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 2 WATER HEATING SYSTEMS Rated 1 Tank Energy Fact! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A O SMITH EPR -50-994 Small Gas Pipe Insulation 43,000 so 0.62 n/a n/a For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or (Owner (per Business & Professions Code) Documentation Author Name: Name: Joan D. Hacker Title/Firm: ( Title/Firm: Insu-Form Inc. Address: 3 SftAddress: 68255 Corta Road Cathedral City, CA 92234 Telepho e: Telephone: (760) 324-0216 Lic. #: $7 LeviD (sign re) (date) (sign". (date) Enf ement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 23 Certificate of Compliance: Residential (Addendum) CF -1 R Sibert Residence 8/24/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "Second Floor" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Second Floor' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "Zone 1" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1225 sgft Exposed Slab Floor, 3.50" thick at Zone 1 The HVAC System "Zone 3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Zone 3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1224 sgft Exposed Slab Floor, 3.50" thick at Zone 3 The HVAC System "Zone 2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 572 sgft Covered Slab Floor, 3.50" thick at Zone 2 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan IField The HVAC System "Second Floor' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Second Floor' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. Run Initiation Time: 08/24/0417:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 23 Certificate of Compliance: Residential (Addendum) CFA R Sibert Residence 8/24/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adecivacv of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan I Field HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 08/24/0417:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:7 of 23 Mandatory Measures Checklist: Residential (Page 1 -of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures '§150(a): Minimum R-19 ceiling insulation. a§150(b): Loose fill insulation manufacturers labeled R -Value. *§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does 1^1 not apply to exterior mass walls). '§150(d): Minimum R-13 raised Floor insulation in framed Floors or equivalent. 0 §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. FX] §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(1): Setback thermostat on all applicable heating and/or cooling systems. F] §1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 23 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) nX 1150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. r IA -11 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3,1 By EnergySoft User Number: 2655 Job Number: Page:9 of 23 Computer Method Summary (Part 1 of 3) C -2R Sibert Residencg 8/24/2004 Project Title Date 77-225 Avenida ArtPaaa I a Quints Project Address Building Permit # Insti-Form Inc (760) 324-0216 plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Climate Zone Source Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 3.53 6.18 -2.65 Space Cooling 35.91 33.22 2.69 Domestic Hot Water 8.36 8.38 -0.02 Totals 47.80 47.78 0.02 Percent better than Standard: 2 Total Conditioned Slab Area: 0.0% Total Conditioned Floor Area: 3,410 ft2 Floor Construction Type: ❑ Raised FloorX❑ Slab Floor Building Type: Single Fam Detached Building Front Orientation: (Northwest) 315 deg Total Fenestration Area: 38.5% Number of Dwelling Units: 1.00 Total Conditioned Volume: 34,936 ft 3 Number of Stories: 2 Total Conditioned Slab Area: 3,021 ft 2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area Sernnd Flnnr 3A9 3 SO 1 nn 111 SIpppinq SIPPpin9Stat n/a Zone 1 1 295 13.475 nn 36 Living- l_ivingStat 8 n/a 7one 3 1994, 12,240 _036_ Sleeping _SIPPpingCt;d 8 n/a Zone 2 572 5,720 0.17 Living Living, tam t 8 n Solar OPAQUE SURFACES Act. Gains Type Area U -Fac. Azm. Tilt Y / N Form 3 Reference Location / Comments Wall 99 0.059 315 3Q ® ❑ R-21 Wall (&21.2x6.16) Second Floor &.all 208 0 059 45 —q0_ ® ❑ R-21 Wall pN 21 20 161 Sernnd Floor wall_ 112 0 059 135 —.Q ®❑ R-21 Wall fW_12 2x616) Second Floor Wall 106 0.059 225 —gQ ®❑ R-21 Wall (&.212x6.16) Sernnd Flnnr Rnnf 389 0.028 315 — ® ❑ R-38 Roof (R_382x14.16) Sernnd Flnor Wall 385 0 054 315 — -go ® ❑ R-21 Wall (&212x6 16) 7nne 1 Wall 16 0.059 0 90 IN ❑ R-21 Wall (&21.2x6.16) 7nne 1 Wall 306 0.059 455o ® ❑ R-21 Wall (&.212x6.16) 7nne 1 Wall 297 0 059 135 A0_ IN ❑ R-21 Wall (W 21 2x6.16) 7nne 1 Wall 426 0 059 299; 5.0_ ®❑ R-21 Wall (VV 21 2x6 16) 7nne 1 Wall 36 0.059 270 90 ® ❑ R-21 Wall (W.21.2x6-161 7nne 1 -Roof— 1 225_ 0.028 135 o ® ❑ R-38 Roof (R.38.2x14.16) 7nne 1 ANall 414 0.059 45_ —90_ IN El R21 Wall (&.21.2x6.16) 7one 3 ANall— 83 0.059 90- 9D- ® ❑ R-21 Wall (W 21 2x6 16) 7nne 3 _uall 176 0059 135 go ®❑ R-21 Wall(,N2t2x616) 7nne' W;411 63 0 059 180 9R ® ❑ R-21 Wall (& 212x6 161 7nne 3 W;;11 252 0 059 225 —g0- ® ❑ R-21 Wall (W 21 2x6 16) Zone 3 Roof 400 0.028 50 n ®❑ R-38 Roof (R 382x14 16) 7nne 3 Wall 93 0.059 _315_ —2Q ®❑ R-21 Wall (1N2t2x6_16) 7nne 2 Wall 254 0.059 45 gn ®❑ R-21 Wall ON 212x6.16) 7nne 2 Wall 32 0.059 5.0 gn ®❑ R-21 Wall QN.21 2x6.16) Zone 2 Wall 60 0 059 135 gn ®❑ R-21 Wall QN 21 2x6.16) 7nne 2 Wall 32 0 059 180 9Q Ex El 2x6.16) Zone 9 wall 146 0 059 925_ qn ® ❑ R-21 Wall (W 212x6.16) 7nne 2 Rnnf 564 0 028 go 0_ ® ❑ R-38 Roof (R 38 2x14 16) Zone 2 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:10 of 23 Computer Method Summary (Part 2 of 3) C -2R Sibert Residence 8/24/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 1 Window Front(Northwest) Wd. 21 0 0 580 wig 31.9 An Milgard Windows Second Floor 2 Window Left (Northeast) 12.0 0.580 0.38 45 90 Milgard Windows Second Floor 3 Window Rear (Southeast) 8.0 0.580 0.38 135 90 Milgard Windows Second Floor 4 Window Right (Southwest) 24.0 0.550 0.38 225 90 Milgard Windows Second Floor 5 Window Right (Southwest) 20.0 0.580 0.38 225 90 Milgard Windows Second Floor 6 Window Front (Northwest) 15.0 0.580 0.38 315 90 Milgard Windows Zone 1 Z Window Front (Northwest) 9.0 0.600 0.38 315 90 Milgard Windows Zone 1 8 Window Front (Northwest) 32.0 0.550 0.38 315 90 Milgard Windows Zone 1 ,9- Window Front(Northwest) 4.0 16.0 0.600 0.38 315 90 Milgard Windows Zone 1 1Q Window Front (Northwest) 19.0 0.600 0.38 315 90 Milgard Windows Zone 1 " Window Front (Northwest) 15.0 0.580 0.38 315 90 Milgard Windows Zone 1 12 Window Front (Northwest) 9.0 0.600 0.38 315 90 Milgard Windows Zone 1 J_a Window Front (North) 15.0 _0_580 0.38 0 90 Milgard Windows Zone 1 14 Window Front (North) 9.0 0.600 0.38 0 90 Milgard Windows Zone 1 15 Window Left (Northeast) 9.0 0.600 0.38 45 90 Milgard Windows Zone 1 16 Window Left (Northeast) 15.0 0.580 0.38 45 90 Milgard Windows Zone 1 17 Window Rear (Southeast) 144.0 0.550 0.38 135 90 Milgard Windows Zone 1 18 Window Rear (Southeast) 59.4 0.600 0.38 135 90 Milgard Windows Zone 1 J,Q Window Right (Southwest) 9.0 0.600 0.38 225 90 Milgard Windows Zone 1 20 Window Right (Southwest) 15.0 0.580 0.38 225 90 Milgard Windows Zone 1 21 Window Right (West) 15.0 0.580 0.38 270 90 Milgard Windows Zone 1 .22 Window Right (West) 9.0 0.600 0.38 270 90 Milgard Windows Zone 1 23 Window Left (Northeast) 25.0 0.580 0.38 45 90 Milgard Windows Zone 3 24 Window Left (Northeast) 24.0 0.580 0.38 45 90 Milgard Windows Zone 3 25 Window Left (Northeast) 24.0 0.580 0.38 45 90 Milqard Windows Zone 3 26 Window Left (Northeast) 13.0 0.600 0.38 45 90 Milgard Windows Zone 3 27 Window Left (East) 24.0 0.580 0.38 90 90 Milgard Windows Zone 3 28 Window Left (East) 13.0 0.600 0.38 90 90 Milgard Windows Zone 3 29 Window Rear (Southeast) 48.0 0.580 0.38 135 90 Milgard Windows Zone 3 INTERIOR AND EXTERIOR SHADING 6.0 4.0 8.0 0.1 8.0 Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 23 Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 4.3 5.0 2.0 0.1 2.0 2.0 2 Buq Screen 0.76 2.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 2.0 4.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 5 Bug Screen 0.76 5.0 4.0 2.0 0.1 2.0 2.0 6 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 7 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 8 Bug Screen 0.76 8.0 4.0 2.0 0.1 2.0 2.0 9 Bug Screen 0.76 8.0 1.0 2.0 0.1 2.0 2.0 10 Bug Screen 0.76 3.1 6.0 2.0 0.1 2.0 2.0 11 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 12 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 13 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 14 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 15 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 16 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 17 Buq Screen 0.76 8.0 6.0 14.0 0.1 14.0 14.0 18 Bug Screen 0.76 3.3 6.0 14.0 0.1 14.0 14.0 19 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 20 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 21 Bug Screen 0.76 5.0 3.0 2.0 0.1 2.0 2.0 22 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 23 Bug Screen 0.76 5.0 5.0 2.0 0.1 2.0 2.0 24 Bug Screen 0.76 3.5 1.8 2.0 0.1 2.0 2.0 25 Bug Screen 0.76 6.0 4.0 2.0 0.1 2.0 2.0 26 Bug Screen 0.76 3.2 4.0 2.0 0.1 2.0 2.0 27 Bug Screen 0.76 6.0 4.0 8.0 0.1 8.0 8.0 28 Bug Screen 0.76 3.3 4.0 2.0 0.1 2.0 _ 2.0 29 Roll -down Awning 0.13 6.0 4.0 8.0 0.1 8.0 _ 8.0 Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 23 Computer Method Summary (Part 2 of 3) C -2R Sibert Residence 8/24/2004 Project Title Date FENESTRATION SURFACES # Type Area U- Factor SHGC Act. Azm. Glazing Type Tilt Location/ Comments 30. Window Rear (Southeast) 96 n 0 600 038 135 -90. Miloard Windows 7one 3 31 Window Rear (South) 13.0 0.600 0.38 180 90 Milgard Windows Zone 3 32 Window Rear (South) 24.0 0.580 0.38 180 90 Milgard Windows Zone 3 33 Window Right (Southwest) 13.0 0.600 0.38 225 90 Milgard Windows Zone 3 34 Window Right (Southwest) 39.0 0.600 0.38 225 90 Milgard Windows Zone 3 35 Window Right (Southwest) 48.0 0.550 0.38 225 90 Milgard Windows Zone 3 3R Window Right (Southwest) 48.0 0.580 0.38 225 90 Milgard Windows Zone 3 37 Skylight Left (East) 9.0 0.450 0.45 90 0 Milgard Windows Zone 3 _$ Window Front orthwest) 30.0 0.580 0.38 315 90 Milgard Windows Zone 2 3R Window Front orthwest) 48.0 0.550 0.38 315 90 Milgard Windows Zone 2 40 Window Front Northwest) 19.0 0.600 0.38 315 90 Milgard Windows Zone 2 41 Window Left (Northeast) 48.0 0.550 0.38 45 90 Milgard Windows Zone 2 92 Window Left (Northeast) 24.0 0.580 0.38 45 90 Milgard Windows Zone 2 43 Window Left (Northeast) 4.5 0.600 0.38 45 90 Milgard Windows Zone 2 44 Window Left (East) 24.0 0.580 0.38 90 90 Milgard Windows Zone 2 45 Window Left (East) 4.5 0.600 0.38 90 90 Milgard Windows Zone 2 46 Window Rear (Southeast) 4.5 0.600 0.38 135 90 Milgard Windows Zone 2 47 Window Rear (Southeast) 24.0 0.550 0.38 135 90 Milgard Windows Zone 2 AB Window Rear (Southeast) 24.0 0.580 0.38 135 90 Milgard Windows Zone 2 49 Window Rear (Southeast) 48.0 0.550 0.38 135 90 Milgard Windows Zone 2 50 Window Rear (South) 24.0 0.580 0.38 180 90 Milgard Windows Zone 2 a Window Rear (South) 4.5 0.600 0.38 180 90 Milgard Windows Zone 2 52 Window Right (Southwest) 18.0 0.580 0.38 225 90 Milgard Windows Zone 2 53 Window Right (Southwest) 20.0 0.600 0.38 225 90 Miilcl and Windows Zone 2 54 Window Right (Southwest) 11.3 0.600 0.38 225 90 Milgard Windows Zone 2 55 Window Right (Southwest) 10.0 0.580 0.38 225 90 Milgard Windows Zone 2 56 Window Right (Southwest) 25.0 0.580 0.38 225 90 Milgard Windows Zone 2 57 Skylight Left (East) 8.0 0.450 0.45 90 0 Milgard Windows Zone 2 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 30 Bug Screen 0.76 3.3 4.0 8.0 0.1 8.0 8.0 31 Buq screen 0.76 3.3 4.0 8.0 0.1 8.0 8.0 32 Bug Screen 0.76 3.3 4.0 8.0 0.1 8.0 8.0 33 Bug Screen 0.76 3.3 4.0 8.0 0.1 8.0 8.0 34 Bug Screen 0.76 3.3 4.0 8.0 0.1 8.0 8.0 35 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 _ 8.0 36 Bug Screen 0.76 6.0 4.0 8.0 0.1 8.0 8.0 37 None 1.00 38 Bug Screen 0.76 5.0 6.0 2.0 0.1 2.0 2.0 39 Bug Screen 0.76 8.0 6.0 2.0 0.1 2.0 2.0 40 Bug Screen 0.76 3.2 6.0 2.0 0.1 2.0 2.0 41 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 42 Bug Screen 0.76 6.0 4.0 8.0 0.1 8.0 8.0 43 Bug Screen 0.76 2.3 2.0 8.0 0.1 8.0 8.0 44 Bug Screen 0.76 6.0 4.0 8.0 0.1 8.0 8.0 45 Bug Screen 0.76 2.3 2.0 8.0 0.1 8.0 8.0 46 Bug Screen 0.76 2.3 2.0 8.0 0.1 8.0 8.0 47 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.0 2.0 48 Bug Screen 0.76 6.0 4.0 10.0 0.1 10.0 10.0 49 Bug Screen 0.76 8.0 6.0 8.0 0.1 8.0 8.0 50 Bug Screen 0.76 6.0 4.0 8.0 0.1 8.0 8.0 51 Bug Screen 0.76 2.3 2.0 8.0 0.1 8.0 8.0 52 Bug Screen 0.76 3.0 3.0 2.0 0.1 2.0 2.0 53 Bug Screen 0.76 4.0 5.0 2.0 0.1 2.0 2.0 54 Bug Screen 0.76 2.3 5.0 2.0 0.1 2.0 2.0 55 Bug Screen 0.76 2.0 5.0 2.0 0.1 2.0 2.0 56 Buq Screen 0.76 5.0 2.5 2.0 0.1 2.0 2.0 57 None 1.00 Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 12 of 23 Computer Method Summary (Part 3 of 3) C -2R Sibert Residence 8/24/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete ea eight 1225. 3 50 98 0 98 n/a 0 lone 1 / Slab on Grade Concrete Heavyweight 1.224 . 3_50 28 0_98 n/a 0 Zone 3 / Slab on Grade Concrete,He�eight 572 3.50 98 0.98 n/a 2 Zone 2 / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length 'Factor R -Val. Depth Location / Comments Slab Perimeter _ 18 –QZfz 0.0 0 Zone 1 Slab Perimeter _ 160 0.76 0.0 —0 Zone 3 Slab Perimeter ___I8 0.76 0.0 0 Zone 2 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPFxducts/attic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Second Floor Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone 1 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone 3 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback Zone 2 Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Second Floor Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 1 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 3 Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 ' Setback Zone 2 WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (al) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Pipe Insulation _2_ X3,000 50 • 0.62 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Computer Method Summary (Addendum) C -2R Sibert Residence 8/24/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The HVAC System "Second Floor' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Second Floor' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "Zone 1" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1225 sqft Exposed Slab Floor, 3.50" thick at Zone 1 The HVAC System "Zone 3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "Zone 3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R - Verify Thermal Mass: 1224 sqft Exposed Slab Floor, 3.50" thick at Zone 3 The HVAC System "Zone 2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 572 sqft Covered Slab Floor, 3.50" thick at Zone 2 HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -61R. Plan I Field The HVAC System "Second Floor" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Second Floor' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone V is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. WA -M EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 23 1 Computer Method Summary (Addendum) C -2R Sibert Residence 8/24/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS Plan I Field provider. i ne rlr-Kb rater must aocument the tiew venncanon and diagnostic testing of tnese measures on a toren t:F-5K. Plan Field The HVAC System "Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. v I -r EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:15 of 23 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Sibert Residence 8/24/2004 SYSTEM NAME FLOOR AREA Second Floor 389 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I I CFM I Sensible 376 5,559 18,11 98 3,991 0 278 200 0 0 0 0 0 0 0 0 0 278 200 6,114T7714 4,3901 BDP CO. 563AN024-A 13,773 7,820 37,000 Total Adjusted System Output 13,773 7,820 37,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am HEATING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Heatina Peak) I 26.0 OF 69.8 OF 69.8 OF 108.4 OF Outside Air 0 cfm Supply Fan Heating Coil 895 cfm 69.8 of i1 Return Air Ducts 4 Supply Air Ducts 108.1 OF ROOMS 70.0 of DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.4OF 78.3/67.6°F 78.3/67.5°F 63.9/62.9OF Supply Air Ducts Outside Air M 0 cfm Supply Fan Cooling Coil 64.2 / 63.0 of 895 cfm 58.6% R.H. FROOMS1 78.3/67.60F 78.0/67.5 OF 1% Return Air Ducts '� EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 16 of 23 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Sibert Residence 8/24/2004 SYSTEM NAME FLOOR AREA Zone 1 1,225 26.0 OF Outside Air 0 cfm 69.5 °F EM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK I COIL HTG. PEAK CFM Sensible Latent I CFM I Sensible 1,952 29,585 3,156 648 27,215 0 1,479 1,361 0 0 0 0 0 0 0 0 0 1,479 1,361 32,544 3 156 29 937 BDP CO. 563AN036-A 42,373 22,753 112,000 Total Adjusted System Output 42,373 22,753 112,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 69.5°F 69.5°F 109.70F ,:::>::: Supply Fan Heating Coil 2600 cfm res at Time of Supply Air Ducts 109.2 of ROOMS 70.0 OF Return Air Ducts I ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Cooling Peak) I 11.0 / 77.4 OF Outside Air 0 cfm 78.5/67.6 ° F 78.5/67.6°F 78.5/67.5°F ® 63.3/62.3°F Supply Fan Cooling Coil 2600 cfm �% Return Air Ducts 4 Supply Air Ducts 63.9 / 62.5 OF 58.3°% R.H. ROOM) 78.0/67.4°F EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:17 of 23 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Sibert Residence 8/24/2004 SYSTEM NAME FLOOR AREA Zone 3 1,224 SYSTEM Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 1,124 17,352 569 485 20,159 0 868 1,008 0 0 0 0 0 0 0 0 0 868 1,008 19,087F77;69 22 175 BDP CO.563AN036-A 21,804 10,518 56,000 Total Adjusted System Output 21,804 10,518 56,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 69.3°F 69.3°F 109.5°F Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 108'7 °F 1300 cfm ROOMS 70.0 OF 69.3 °F i k Return Air Ducts `{ ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak) I 11.0/77.4°F 78.6/67.1°F 78.6/67.0°F ® 63.0/61.9°F Outside Air 0 cfm 78.6/67.1 ° F Supply Fan Cooling Coil 1300 cfm h Return Air Ducts `I Supply Air Ducts 63.6/62.1OF 56.6% R.H. ROOMS 78.0/66.9°F EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 18 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Sibert Residence 8/24/2004 SYSTEM NAME FLOOR AREA Zone 2 572 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems t Heating System Output per System 56,000 Total Output (Btuh) 56,000 Output (Btuh/sgft) 97.9 Cooling System Output per System 35,000 Total Output (Btuh) 35,000 Total Output (Tons) 2.9 Total Output (Btuh/sqft) 61.2 Total Output (sgft/Ton) 196.1 Air System CFM per System 1,300 Airflow (cfm) 1,300 Airflow (cfm/sqft) 2.27 Airflow (cfm/Ton) 445.7 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,143 17,770 266 326 13,701 0 888 685 0 0 0 0 0 0 0 0 0 888 685 19 547 266 HVAC EQUIPMENT SELECTION BDP CO. 563AN036-A 21,983 10,262 Total Adjusted System Output 21 983 10,262 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm 56,000 56,000 Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 69.5°F 69.5°F 109.7°F .1 00W Supply Air Ducts Outside Air 0 cfm Supply Fan Heating Coil 109.2 °F 1300 cfm ROOMS 70.0 OF 69.5 °F f% Return Air Ducts 4 ratures at Time of Cooli 11.0/77.4°F 78.6/67.0°F 78.6/66.9°F 62.9/61.8°F i!^ Outside Air 0 cfm 78.6/67.0 ° F Supply Fan Cooling Coil 1300 cfm K Return Air Ducts `i Supply Air Ducts 63.5 / 62.0 OF 56.1% R. H. ROO6+c 78.0/66.8°F EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:19 of 23 ROOM LOAD SUMMARY PROJECT NAME Sibert Residence DATE 8/24/2004 SYSTEM NAME Second Floor FLOOR AREA 389 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Second Floor Second Floor 1 376 5,559 181 376 5,559 181 98 3,991 PAGE TOTAL 1 376 5,559 181 98 3,991 TOTAL 1 376 5,559 18111 98 3,991 EnergyPro 3.1 By EnergySofl User Number: 2655 Job Number: Page:20 of 23 ROOM LOAD SUMMARY PROJECT NAME Sibert Residence DATE 8/24/2004 SYSTEM NAME Zone 1 FLOOR AREA 1,225 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 1 Zone 1 1 1,952 29,585 3,156 1,952 29,585 3,156 648 27,215 PAGE TOTAL TOTAL 1 1,952 29,585 3,156 648 27,215 1 1,952 29,585 3,156 648 27,215 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:21 of 23 ROOM LOAD SUMMARY PROJECT NAME Sibert Residence DATE 8/24/2004 SYSTEM NAME Zone 3 FLOOR AREA 1,224 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 3 Zone 3 1 1,124 17,352 569 1,124 17,352 569 485 20,159 PAGE TOTAL 1 1,124 17,352 569 485 20,159 TOTAL 1 1,124 17,352 56911 485 20,159 EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:22 of 23 ROOM LOAD SUMMARY PROJECT NAME Sibert Residence DATE 8/24/2004 SYSTEM NAME Zone 2 FLOOR AREA 572 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Zone 2 Zone 2 1 1 143 17,770 266 1,143 17,770 266 326 13,701 PAGE TOTAL 1 1,143 17,770 266 326 13,701 TOTAL 1 1,143 17,770 266 326 13,701 EnergyPro 3.1 By EnergySofl User Number: 2655 Job Number: Page: 23 of 23