04-5066 (SFD) Title 24F
rA
I
TITLE 24 REPORT
Title 24 Report for:
Sibert Residence
77-225 Avenida Arteaga
La Quinta, CA
CITY OF LA QUANTA
BUILDING & SAFETY DEPT.
APPROVE 1 ro' ct Designer:
FOR CONST UCTI 9
DATE Q 113 04 g
Report Prepared By:
Joan D. Hacker.
Insu-Form Inc.
68255 Corta Road
Cathedral City, CA 92234
(760) 324-0216
Job Number:
Date:
8i24i2004
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC (415) 897-6400.
EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655
77*425 HuE 01"FRGA FF1
kc
F TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Checklist
Form C -2R Computer Method Summary
HVAC System Heating and Cooling Loads Summary
Room Load Summary
1
2
3
8
10
16
20
EnergyPro 3.1 By EnergySoft Job Number: User Number: 2655 1
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Sibert Residence 8/24/2004
Project Title Date
77-225 Avenida Arteapa La Quinta
Project Address Building Permit #
Insu-Form Inc. (760) 324-0216 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,410 ft2 Average Ceiling Height: 10.2 ft
Total Conditioned Slab Area: 3,021 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (Northwest) 315 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 2 ❑ Raised Floor
Component
Tvpe
Const.
Frame Assembly Location/Comments
Type U -Value (attic, garage, typical, etc.)
R-21 Wall (W.21.2x6.16)
Wood
0.059
Exterior Wall
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof
Slab On Grade
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
FENESTRATION
Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shading
Yes / No
Yes
/ No
Front
(Northwest)
81.0
0.58
0.38
Bug
Screen
X❑
❑
❑
X❑
Left
(Northeast)
124.0
0.58
0.38
Bug
Screen
X❑
❑
❑
X❑
Rear
(Southeast)
32.0
0.58
0.38
Bug
Screen
X❑
❑
❑
x❑
Right
(Southwest)
72.0
0.55
0.38
Bug
Screen
X❑
❑
❑
x❑
Right
(Southwest)
136.0
0.58
0.38
Bug
Screen
X❑
❑
❑
X❑
Front
(Northwest)
72.0
0.60
0.38
Bug
Screen[i]
❑
❑
X❑
Front
(Northwest)
80.0
0.55
0.38
Bug
Screen
x❑
❑
❑X❑
Front
(North)
15.0
0.58
0.38
Bug
Screen
X❑
❑
❑
X❑
Front
(North)
9.0
0.60
0.38
Bug
Screen
X❑
❑
❑
X❑
Left
(Northeast)
26.5
0.60
0.38
Bug
Screen
X❑
❑
❑
X❑
Rear
(Southeast)
216.0
0.55
0.38
Bug
Screen
X❑
❑
❑
X❑
Rear
(Southeast)
89.9
0.60
0.38
Bug
Screen
X❑
❑
❑
x❑
Run Initiation
Time: 08/24/04 17:28:36 Run Code: 1093393716
E nergyPro
3.1 By Ener Soft
User Number: 2655
Job Number:
Pa e:3 of 23
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
Sibert Residence . 8/24/2004
Project Title Date
77-225 Avenida Arteaga La Quinta
Project Address Building Permit #
Insu-Form Inc. (760) 324-0216 Plan Check / Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: 3,410 ft2 Average Ceiling Height: 10.2 ft
Total Conditioned Slab Area: 3,021 ft2
Building Type:
(check one or more)
X❑ Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: (Northwest) 315 deg Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 2 ❑ Raised Floor
BUILDING SHELL INSULATION
Const.
Component Frame Assembly Location/Comments
Type Type U -Value (attic, garage, typical, etc.)
FENESTRATION Shading Devices
Type
Orientation
Area
Fenestration
Exterior
Overhang Side Fins
SF
U -Factor
SHGC
Shadinq
Yes / No
Yes / No
Right
(Southwest)
92.3
0.60
0.38
Bug Screen
X❑
❑
❑ 0
Right
(West)
15.0
0.58
0.38
Bug Screen
0
❑
❑ 0
Right
(West)
9.0
0.60
0.38
Bug Screen
0
El
El 0
Left
(East)
48.0
0.58
0.38
Bug Screen
X❑
❑
❑ X❑
Left
(East)
17.5
0.60
0.38
Bug Screen
X❑
❑
❑ X❑
Rear
(Southeast)
48.0
0.58
0.38
Roll -down Awning_
0
❑
❑ 0
Rear
(South)
17.5
0.60
0.38
Bug Screen
0
❑
❑X❑
Rear
(South)
48.0
0.58
0.38
Bug Screen
0
❑
❑ o
Skylight
17.0
0.45
0.45
None
❑
X❑
❑X❑
Left
(Northeast)
48.0
0.55
0.38
Bug ScreenX❑
❑
❑ 0
1:1
El
❑❑
1:1
1:1
❑❑
Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716
Ener Pro 3.1 By Ener
Soft
User Number: 2655
Job Number:
Pa e:4 of 23
Certificate of Compliance: Residential (Part 2 of 2) CF -1 R
Sibert Residence 8/24/2004
Project Title Date
HVAC SYSTEMS
Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Tank
Distribution
External
Water Heater Water Heater Distribution
# in Input
Heating Equipment
Minimum Type and
Duct or
System Name Type Type
Syst. Btu/hr
Type (furnace, heat,
Efficiency Location
Piping
Thermostat
Location /
pump, etc.)
(AFUE/HSPF)(ducts, attic, etc.)
R -Value
Type
Comments
r:entral Furnace
80°% AFUE Ducts in Attic
4.2
Setback
Second Floor
Central Furnace
Central F urna .
80°% AFUE Ducts in Attic
80°% AFUE Ducts in Attic
42
4.2
Setback
Setback
lone 1
Zone 3
(ventral Furnace
80°% AFUE Ducts in Attic
4.2
Setback
Zone 2
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 42 sethack SPrnnd Flnnr
Split Air Conditioner 12 0 SEER Ducts in Attic 4_7 Setback 7nne 1
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 3
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback Zone 2
WATER HEATING SYSTEMS
Rated 1
Tank
Energy Fact! 1
External
Water Heater Water Heater Distribution
# in Input
Cap.
or Recovery Standby
Tank Insul.
System Name Type Type
Syst. Btu/hr
(gal)
Efficiency Loss (%)
R -Value
A O SMITH EPR -50-994 Small Gas Pipe Insulation
43,000
so
0.62 n/a
n/a
For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification
and field verification by an approved HERS rater.
Designer or (Owner (per Business & Professions Code) Documentation Author
Name: Name: Joan D. Hacker
Title/Firm: ( Title/Firm: Insu-Form Inc.
Address: 3 SftAddress: 68255 Corta Road
Cathedral City, CA 92234
Telepho e: Telephone: (760) 324-0216
Lic. #:
$7 LeviD
(sign re) (date) (sign". (date)
Enf ement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature/stamp) (date)
Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:5 of 23
Certificate of Compliance: Residential (Addendum) CF -1 R
Sibert Residence 8/24/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "Second Floor" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "Second Floor' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
The HVAC System "Zone 1" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1225 sgft Exposed Slab Floor, 3.50" thick at Zone 1
The HVAC System "Zone 3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "Zone 3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1224 sgft Exposed Slab Floor, 3.50" thick at Zone 3
The HVAC System "Zone 2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 572 sgft Covered Slab Floor, 3.50" thick at Zone 2
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan IField
The HVAC System "Second Floor' includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Second Floor' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Zone 1" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed
by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed
by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
Run Initiation Time: 08/24/0417:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:6 of 23
Certificate of Compliance: Residential (Addendum) CFA R
Sibert Residence 8/24/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement aaencv determines the adecivacv of the justification, and may reject a building or design that otherwise complies
)ased on the adequacy of the special justification and documentation submitted.
Plan I Field
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field
The HVAC System "Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed
by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 08/24/0417:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:7 of 23
Mandatory Measures Checklist: Residential (Page 1 -of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Building Envelope Measures
'§150(a): Minimum R-19 ceiling insulation.
a§150(b): Loose fill insulation manufacturers labeled R -Value.
*§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does
1^1 not apply to exterior mass walls).
'§150(d): Minimum R-13 raised Floor insulation in framed Floors or equivalent.
0
§150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
FX] §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
§150(1): Setback thermostat on all applicable heating and/or cooling systems.
F] §1500): Pipe and Tank Insulation
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
insulation having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:8 of 23
Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
nX 1150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601,
603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in
conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system
that meets the applicable requirements of UL181, UL181 A, or UL181 B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not
be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and
drawbands.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other
than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building
cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be
compressed to cause reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
duct tapes unless such a tape is used in combination with mastic and drawbands.
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually
operated dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture,
equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable
for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam
insulation shall be protected as above or painted with a coating that is water retardant and provides shielding
from solar radiation that can cause degradation of the material.
❑ §114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance
heating, and no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or
spas.
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation pump time switch.
X❑ §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no
continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
❑ §118 (f): Cool Roof material meet specified criteria
Lighting Measures
® §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for
general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting
control panel at an entrance to the kitchen.
r IA -11 §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of
40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement
allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved.
3,1 By EnergySoft User Number: 2655 Job Number: Page:9 of 23
Computer Method Summary (Part 1 of 3) C -2R
Sibert Residencg 8/24/2004
Project Title Date
77-225 Avenida ArtPaaa I a Quints
Project Address Building Permit #
Insti-Form Inc (760) 324-0216 plan Check/Date
Documentation Author Telephone
Computer Performance 15 Field Check/Date
Compliance Method (Package or Computer) Climate Zone
Source Energy Use Standard Proposed Compliance
(kBtu/sf-yr) Design Design Margin
Space Heating
3.53
6.18
-2.65
Space Cooling
35.91
33.22
2.69
Domestic Hot Water
8.36
8.38
-0.02
Totals
47.80
47.78
0.02
Percent better than Standard:
2
Total Conditioned Slab Area:
0.0%
Total Conditioned Floor Area:
3,410 ft2
Floor Construction Type: ❑
Raised FloorX❑ Slab Floor
Building Type:
Single Fam Detached
Building Front Orientation:
(Northwest) 315 deg
Total Fenestration Area:
38.5%
Number of Dwelling Units:
1.00
Total Conditioned Volume:
34,936 ft 3
Number of Stories:
2
Total Conditioned Slab Area:
3,021 ft 2
BUILDING ZONE INFORMATION
# of Thermostat Vent
Zone Name
Floor Area Volume
Units Zone Type
Type Hgt. Area
Sernnd Flnnr
3A9 3 SO 1
nn 111 SIpppinq SIPPpin9Stat
n/a
Zone 1
1 295 13.475
nn 36 Living-
l_ivingStat 8 n/a
7one 3
1994, 12,240
_036_ Sleeping _SIPPpingCt;d
8 n/a
Zone 2
572 5,720
0.17 Living
Living, tam t 8 n
Solar
OPAQUE SURFACES Act.
Gains
Type Area U -Fac. Azm.
Tilt Y / N Form
3 Reference Location / Comments
Wall 99 0.059 315
3Q ® ❑ R-21 Wall (&21.2x6.16)
Second Floor
&.all 208 0 059 45
—q0_ ® ❑ R-21 Wall pN 21
20 161 Sernnd Floor
wall_ 112 0 059 135
—.Q ®❑ R-21 Wall fW_12
2x616) Second Floor
Wall 106 0.059 225
—gQ ®❑ R-21 Wall (&.212x6.16)
Sernnd Flnnr
Rnnf 389 0.028 315
— ® ❑ R-38 Roof (R_382x14.16)
Sernnd Flnor
Wall 385 0 054 315
— -go ® ❑ R-21 Wall (&212x6
16) 7nne 1
Wall 16 0.059 0
90 IN ❑ R-21 Wall (&21.2x6.16)
7nne 1
Wall 306 0.059 455o
® ❑ R-21 Wall (&.212x6.16)
7nne 1
Wall 297 0 059 135
A0_ IN ❑ R-21 Wall (W 21
2x6.16) 7nne 1
Wall 426 0 059 299;
5.0_ ®❑ R-21 Wall (VV 21
2x6 16) 7nne 1
Wall 36 0.059 270
90 ® ❑ R-21 Wall (W.21.2x6-161
7nne 1
-Roof— 1 225_ 0.028 135
o ® ❑ R-38 Roof (R.38.2x14.16)
7nne 1
ANall 414 0.059 45_
—90_ IN El R21 Wall (&.21.2x6.16)
7one 3
ANall— 83 0.059 90-
9D- ® ❑ R-21 Wall (W 21
2x6 16) 7nne 3
_uall 176 0059 135
go ®❑ R-21 Wall(,N2t2x616)
7nne'
W;411 63 0 059 180
9R ® ❑ R-21 Wall (& 212x6
161 7nne 3
W;;11 252 0 059 225
—g0- ® ❑ R-21 Wall (W 21
2x6 16) Zone 3
Roof 400 0.028 50
n ®❑ R-38 Roof (R 382x14
16) 7nne 3
Wall 93 0.059 _315_
—2Q ®❑ R-21 Wall (1N2t2x6_16)
7nne 2
Wall 254 0.059 45
gn ®❑ R-21 Wall ON 212x6.16)
7nne 2
Wall 32 0.059 5.0
gn ®❑ R-21 Wall QN.21
2x6.16) Zone 2
Wall 60 0 059 135
gn ®❑ R-21 Wall QN 21
2x6.16) 7nne 2
Wall 32 0 059 180
9Q Ex El
2x6.16) Zone 9
wall 146 0 059 925_
qn ® ❑ R-21 Wall (W 212x6.16)
7nne 2
Rnnf 564 0 028 go
0_ ® ❑ R-38 Roof (R 38
2x14 16) Zone 2
❑ ❑
❑ ❑
❑ ❑
❑ ❑
Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft
User Number: 2655
Job Number:
Paae:10 of 23
Computer Method Summary (Part 2 of 3) C -2R
Sibert Residence 8/24/2004
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
1
Window
Front(Northwest)
Wd.
21 0
0 580
wig
31.9
An Milgard Windows
Second Floor
2
Window
Left
(Northeast)
12.0
0.580
0.38
45
90 Milgard Windows
Second Floor
3
Window
Rear
(Southeast)
8.0
0.580
0.38
135
90 Milgard Windows
Second Floor
4
Window
Right
(Southwest)
24.0
0.550
0.38
225
90 Milgard Windows
Second Floor
5
Window
Right
(Southwest)
20.0
0.580
0.38
225
90 Milgard Windows
Second Floor
6
Window
Front
(Northwest)
15.0
0.580
0.38
315
90 Milgard Windows
Zone 1
Z
Window
Front
(Northwest)
9.0
0.600
0.38
315
90 Milgard Windows
Zone 1
8
Window
Front
(Northwest)
32.0
0.550
0.38
315
90 Milgard Windows
Zone 1
,9-
Window
Front(Northwest)
4.0
16.0
0.600
0.38
315
90 Milgard Windows
Zone 1
1Q
Window
Front
(Northwest)
19.0
0.600
0.38
315
90 Milgard Windows
Zone 1
"
Window
Front
(Northwest)
15.0
0.580
0.38
315
90 Milgard Windows
Zone 1
12
Window
Front
(Northwest)
9.0
0.600
0.38
315
90 Milgard Windows
Zone 1
J_a
Window
Front
(North)
15.0
_0_580
0.38
0
90 Milgard Windows
Zone 1
14
Window
Front
(North)
9.0
0.600
0.38
0
90 Milgard Windows
Zone 1
15
Window
Left
(Northeast)
9.0
0.600
0.38
45
90 Milgard Windows
Zone 1
16
Window
Left
(Northeast)
15.0
0.580
0.38
45
90 Milgard Windows
Zone 1
17
Window
Rear
(Southeast)
144.0
0.550
0.38
135
90 Milgard Windows
Zone 1
18
Window
Rear
(Southeast)
59.4
0.600
0.38
135
90 Milgard Windows
Zone 1
J,Q
Window
Right
(Southwest)
9.0
0.600
0.38
225
90 Milgard Windows
Zone 1
20
Window
Right
(Southwest)
15.0
0.580
0.38
225
90 Milgard Windows
Zone 1
21
Window
Right
(West)
15.0
0.580
0.38
270
90 Milgard Windows
Zone 1
.22
Window
Right
(West)
9.0
0.600
0.38
270
90 Milgard Windows
Zone 1
23
Window
Left
(Northeast)
25.0
0.580
0.38
45
90 Milgard Windows
Zone 3
24
Window
Left
(Northeast)
24.0
0.580
0.38
45
90 Milgard Windows
Zone 3
25
Window
Left
(Northeast)
24.0
0.580
0.38
45
90 Milqard Windows
Zone 3
26
Window
Left
(Northeast)
13.0
0.600
0.38
45
90 Milgard Windows
Zone 3
27
Window
Left
(East)
24.0
0.580
0.38
90
90 Milgard Windows
Zone 3
28
Window
Left
(East)
13.0
0.600
0.38
90
90 Milgard Windows
Zone 3
29
Window
Rear
(Southeast)
48.0
0.580
0.38
135
90 Milgard Windows
Zone 3
INTERIOR AND EXTERIOR SHADING
6.0
4.0
8.0
0.1
8.0
Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 23
Window
Overhang
Left Fin Right Fin
#
Exterior
Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt.
LExt.
REA. Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug
Screen
0.76
4.3
5.0
2.0
0.1
2.0
2.0
2
Buq
Screen
0.76
2.0
2.0
2.0
0.1
2.0
2.0
3
Bug
Screen
0.76
2.0
4.0
2.0
0.1
2.0
2.0
4
Bug
Screen
0.76
8.0
3.0
2.0
0.1
2.0
2.0
5
Bug
Screen
0.76
5.0
4.0
2.0
0.1
2.0
2.0
6
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
7
Bug
Screen
0.76
3.0
3.0
2.0
0.1
2.0
2.0
8
Bug
Screen
0.76
8.0
4.0
2.0
0.1
2.0
2.0
9
Bug
Screen
0.76
8.0
1.0
2.0
0.1
2.0
2.0
10
Bug
Screen
0.76
3.1
6.0
2.0
0.1
2.0
2.0
11
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
12
Bug
Screen
0.76
3.0
3.0
2.0
0.1
2.0
2.0
13
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
14
Bug
Screen
0.76
3.0
3.0
2.0
0.1
2.0
2.0
15
Bug
Screen
0.76
3.0
3.0
2.0
0.1
2.0
2.0
16
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
17
Buq
Screen
0.76
8.0
6.0
14.0
0.1
14.0
14.0
18
Bug
Screen
0.76
3.3
6.0
14.0
0.1
14.0
14.0
19
Bug
Screen
0.76
3.0
3.0
2.0
0.1
2.0
2.0
20
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
21
Bug
Screen
0.76
5.0
3.0
2.0
0.1
2.0
2.0
22
Bug
Screen
0.76
3.0
3.0
2.0
0.1
2.0
2.0
23
Bug
Screen
0.76
5.0
5.0
2.0
0.1
2.0
2.0
24
Bug
Screen
0.76
3.5
1.8
2.0
0.1
2.0
2.0
25
Bug
Screen
0.76
6.0
4.0
2.0
0.1
2.0
2.0
26
Bug
Screen
0.76
3.2
4.0
2.0
0.1
2.0
2.0
27
Bug
Screen
0.76
6.0
4.0
8.0
0.1
8.0
8.0
28
Bug
Screen
0.76
3.3
4.0
2.0
0.1
2.0
_
2.0
29
Roll -down Awning
0.13
6.0
4.0
8.0
0.1
8.0
_
8.0
Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 11 of 23
Computer Method Summary (Part 2 of 3) C -2R
Sibert Residence 8/24/2004
Project Title Date
FENESTRATION SURFACES
# Type
Area
U-
Factor
SHGC
Act.
Azm.
Glazing Type
Tilt
Location/
Comments
30.
Window Rear
(Southeast)
96 n
0 600
038
135
-90.
Miloard Windows
7one 3
31
Window Rear
(South)
13.0
0.600
0.38
180
90 Milgard Windows
Zone 3
32
Window Rear
(South)
24.0
0.580
0.38
180
90 Milgard Windows
Zone 3
33
Window Right
(Southwest)
13.0
0.600
0.38
225
90 Milgard Windows
Zone 3
34
Window Right
(Southwest)
39.0
0.600
0.38
225
90 Milgard Windows
Zone 3
35
Window Right
(Southwest)
48.0
0.550
0.38
225
90 Milgard Windows
Zone 3
3R
Window Right
(Southwest)
48.0
0.580
0.38
225
90 Milgard Windows
Zone 3
37
Skylight Left
(East)
9.0
0.450
0.45
90
0 Milgard Windows
Zone 3
_$
Window Front
orthwest)
30.0
0.580
0.38
315
90 Milgard Windows
Zone 2
3R
Window Front
orthwest)
48.0
0.550
0.38
315
90 Milgard Windows
Zone 2
40
Window Front
Northwest)
19.0
0.600
0.38
315
90 Milgard Windows
Zone 2
41
Window Left
(Northeast)
48.0
0.550
0.38
45
90 Milgard Windows
Zone 2
92
Window Left
(Northeast)
24.0
0.580
0.38
45
90 Milgard Windows
Zone 2
43
Window Left
(Northeast)
4.5
0.600
0.38
45
90 Milgard Windows
Zone 2
44
Window Left
(East)
24.0
0.580
0.38
90
90 Milgard Windows
Zone 2
45
Window Left
(East)
4.5
0.600
0.38
90
90 Milgard Windows
Zone 2
46
Window Rear
(Southeast)
4.5
0.600
0.38
135
90 Milgard Windows
Zone 2
47
Window Rear
(Southeast)
24.0
0.550
0.38
135
90 Milgard Windows
Zone 2
AB
Window Rear
(Southeast)
24.0
0.580
0.38
135
90 Milgard Windows
Zone 2
49
Window Rear
(Southeast)
48.0
0.550
0.38
135
90 Milgard Windows
Zone 2
50
Window Rear
(South)
24.0
0.580
0.38
180
90 Milgard Windows
Zone 2
a
Window Rear
(South)
4.5
0.600
0.38
180
90 Milgard Windows
Zone 2
52
Window Right
(Southwest)
18.0
0.580
0.38
225
90 Milgard Windows
Zone 2
53
Window Right
(Southwest)
20.0
0.600
0.38
225
90 Miilcl and Windows
Zone 2
54
Window Right
(Southwest)
11.3
0.600
0.38
225
90 Milgard Windows
Zone 2
55
Window Right
(Southwest)
10.0
0.580
0.38
225
90 Milgard Windows
Zone 2
56
Window Right
(Southwest)
25.0
0.580
0.38
225
90 Milgard Windows
Zone 2
57
Skylight Left
(East)
8.0
0.450
0.45
90
0 Milgard Windows
Zone 2
INTERIOR AND EXTERIOR SHADING
Window
Overhang Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len. Hgt.
LExt. RExt. Dist. Len.
Hgt. Dist. Len. Hgt.
30
Bug Screen
0.76
3.3
4.0
8.0
0.1
8.0 8.0
31
Buq screen
0.76
3.3
4.0
8.0
0.1
8.0 8.0
32
Bug Screen
0.76
3.3
4.0
8.0
0.1
8.0 8.0
33
Bug Screen
0.76
3.3
4.0
8.0
0.1
8.0 8.0
34
Bug Screen
0.76
3.3
4.0
8.0
0.1
8.0 8.0
35
Bug Screen
0.76
8.0
6.0
8.0 0.1
8.0 _ 8.0
36
Bug Screen
0.76
6.0
4.0
8.0
0.1
8.0 8.0
37
None
1.00
38
Bug Screen
0.76
5.0
6.0
2.0
0.1
2.0 2.0
39
Bug Screen
0.76
8.0
6.0
2.0
0.1
2.0 2.0
40
Bug Screen
0.76
3.2
6.0
2.0
0.1
2.0 2.0
41
Bug Screen
0.76
8.0
6.0
8.0
0.1
8.0 8.0
42
Bug Screen
0.76
6.0
4.0
8.0
0.1
8.0 8.0
43
Bug Screen
0.76
2.3
2.0
8.0
0.1
8.0 8.0
44
Bug Screen
0.76
6.0
4.0
8.0
0.1
8.0 8.0
45
Bug Screen
0.76
2.3
2.0
8.0
0.1
8.0 8.0
46
Bug Screen
0.76
2.3
2.0
8.0
0.1
8.0 8.0
47
Bug Screen
0.76
8.0
3.0
2.0
0.1
2.0 2.0
48
Bug Screen
0.76
6.0
4.0
10.0
0.1
10.0 10.0
49
Bug Screen
0.76
8.0
6.0
8.0
0.1
8.0 8.0
50
Bug Screen
0.76
6.0
4.0
8.0
0.1
8.0 8.0
51
Bug Screen
0.76
2.3
2.0
8.0
0.1
8.0 8.0
52
Bug Screen
0.76
3.0
3.0
2.0
0.1
2.0 2.0
53
Bug Screen
0.76
4.0
5.0
2.0
0.1
2.0 2.0
54
Bug Screen
0.76
2.3
5.0
2.0
0.1
2.0 2.0
55
Bug Screen
0.76
2.0
5.0
2.0
0.1
2.0 2.0
56
Buq Screen
0.76
5.0
2.5
2.0
0.1
2.0 2.0
57
None
1.00
Run Initiation Time: 08/24/04 17:28:36 Run Code: 1093393716
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 12 of 23
Computer Method Summary (Part 3 of 3) C -2R
Sibert Residence 8/24/2004
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Concrete ea eight 1225. 3 50 98 0 98 n/a 0 lone 1 / Slab on Grade
Concrete Heavyweight 1.224 . 3_50 28 0_98 n/a 0 Zone 3 / Slab on Grade
Concrete,He�eight 572 3.50 98 0.98 n/a 2 Zone 2 / Slab on Grade
PERIMETER LOSSES
F2 Insulation
Type Length 'Factor R -Val. Depth Location / Comments
Slab Perimeter _ 18 –QZfz 0.0 0 Zone 1
Slab Perimeter _ 160 0.76 0.0 —0 Zone 3
Slab Perimeter ___I8 0.76 0.0 0 Zone 2
HVAC SYSTEMS
Heating Equipment
Minimum
Distribution Type
Type (furnace, heat
Efficiency
and Location
Duct
Thermostat
Location /
pump, etc.)
(AFUE/HSPFxducts/attic,
etc.)
R -Value
Type
Comments
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
Second Floor
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
Zone 1
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
Zone 3
Central Furnace
80% AFUE
Ducts in Attic
4.2
Setback
Zone 2
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment
Minimum
Duct
Type (air conditioner,
Efficiency
Location
Duct Thermostat
Location /
heat pump, evap. cooling)
(SEER)
(attic, etc)
R -Value Type
Comments
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2
Setback
Second Floor
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2
Setback
Zone 1
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2
Setback
Zone 3
Split Air Conditioner
12.0 SEER
Ducts in Attic
4.2 '
Setback
Zone 2
WATER HEATING SYSTEMS
Ratedl
Tank
Energy Facts
1 Tank Insul.
Water Heater
Water Heater Distribution
# in Input
Cap.
or Recovery
Standby R -Value
System Name
Type
Type
Syst. (Btu/hr)
(al)
Efficiency
Loss (%) Ext.
A.O. SMITH FPS -50-224
Small Gas
Pipe Insulation
_2_ X3,000
50
• 0.62
n/a n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
Computer Method Summary (Addendum) C -2R
Sibert Residence 8/24/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
based on the adequacy of the special justification and documentation submitted. I Plan I Field
The HVAC System "Second Floor' must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "Second Floor' includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
The HVAC System "Zone 1" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "Zone 1" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1225 sqft Exposed Slab Floor, 3.50" thick at Zone 1
The HVAC System "Zone 3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas.
The HVAC System "Zone 3" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R - Verify Thermal Mass: 1224 sqft Exposed Slab Floor, 3.50" thick at Zone 3
The HVAC System "Zone 2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas.
The HVAC System "Zone 2" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 572 sqft Covered Slab Floor, 3.50" thick at Zone 2
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -61R. Plan I Field
The HVAC System "Second Floor" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Second Floor' is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Zone 1" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Zone V is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed
by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Zone 3" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "Zone 3" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed
by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
The HVAC System "Zone 2" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verification of the TXV, or measure the Refrigerant Charge and Airflow.
WA -M
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 14 of 23 1
Computer Method Summary (Addendum) C -2R
Sibert Residence 8/24/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
)ased on the adequacy of the special justification and documentation submitted.
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
Plan I Field
provider. i ne rlr-Kb rater must aocument the tiew venncanon and diagnostic testing of tnese measures on a toren t:F-5K.
Plan
Field
The HVAC System "Zone 2" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed
by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
v I -r
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:15 of 23 1
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Sibert Residence 8/24/2004
SYSTEM NAME FLOOR AREA
Second Floor 389
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
I I CFM
I Sensible
376
5,559
18,11
98
3,991
0
278
200
0
0
0
0
0
0
0
0
0
278
200
6,114T7714 4,3901
BDP CO. 563AN024-A 13,773 7,820 37,000
Total Adjusted System Output 13,773 7,820 37,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
HEATING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Heatina Peak) I
26.0 OF 69.8 OF 69.8 OF 108.4 OF
Outside Air
0 cfm
Supply Fan Heating Coil
895 cfm
69.8 of
i1 Return Air Ducts 4
Supply Air Ducts
108.1 OF
ROOMS
70.0 of
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0/77.4OF 78.3/67.6°F 78.3/67.5°F 63.9/62.9OF
Supply Air Ducts
Outside Air M
0 cfm Supply Fan Cooling Coil 64.2 / 63.0 of
895 cfm 58.6% R.H. FROOMS1
78.3/67.60F 78.0/67.5 OF
1% Return Air Ducts '�
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 16 of 23
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Sibert Residence 8/24/2004
SYSTEM NAME FLOOR AREA
Zone 1 1,225
26.0 OF
Outside Air
0 cfm
69.5 °F
EM LOAD
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
I COIL HTG. PEAK
CFM
Sensible
Latent
I CFM
I Sensible
1,952
29,585
3,156
648
27,215
0
1,479
1,361
0
0
0
0
0
0
0
0
0
1,479
1,361
32,544 3 156 29 937
BDP CO. 563AN036-A 42,373 22,753 112,000
Total Adjusted System Output 42,373 22,753 112,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
69.5°F 69.5°F 109.70F
,:::>:::
Supply Fan Heating Coil
2600 cfm
res at Time of
Supply Air Ducts
109.2 of
ROOMS
70.0 OF
Return Air Ducts I
ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temoeratures at Time of Cooling Peak) I
11.0 / 77.4 OF
Outside Air
0 cfm
78.5/67.6 ° F
78.5/67.6°F 78.5/67.5°F ® 63.3/62.3°F
Supply Fan Cooling Coil
2600 cfm
�% Return Air Ducts 4
Supply Air Ducts
63.9 / 62.5 OF
58.3°% R.H. ROOM)
78.0/67.4°F
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Paae:17 of 23 1
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Sibert Residence 8/24/2004
SYSTEM NAME FLOOR AREA
Zone 3 1,224
SYSTEM
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensiblel
Latent
I CFM
I Sensible
1,124
17,352
569
485
20,159
0
868
1,008
0
0
0
0
0
0
0
0
0
868
1,008
19,087F77;69 22 175
BDP CO.563AN036-A 21,804 10,518 56,000
Total Adjusted System Output 21,804 10,518 56,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0°F 69.3°F 69.3°F 109.5°F
Supply Air Ducts
Outside Air
0 cfm Supply Fan Heating Coil 108'7 °F
1300 cfm ROOMS
70.0 OF
69.3 °F i
k Return Air Ducts `{
ICOOLING SYSTEM PSYCHROMETRICS (Airstream Temaeratures at Time of Coolina Peak) I
11.0/77.4°F 78.6/67.1°F 78.6/67.0°F ® 63.0/61.9°F
Outside Air
0 cfm
78.6/67.1 ° F
Supply Fan Cooling Coil
1300 cfm
h Return Air Ducts `I
Supply Air Ducts
63.6/62.1OF
56.6% R.H. ROOMS
78.0/66.9°F
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page: 18 of 23
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Sibert Residence 8/24/2004
SYSTEM NAME FLOOR AREA
Zone 2 572
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
t
Heating System
Output per System
56,000
Total Output (Btuh)
56,000
Output (Btuh/sgft)
97.9
Cooling System
Output per System
35,000
Total Output (Btuh)
35,000
Total Output (Tons)
2.9
Total Output (Btuh/sqft)
61.2
Total Output (sgft/Ton)
196.1
Air System
CFM per System
1,300
Airflow (cfm)
1,300
Airflow (cfm/sqft)
2.27
Airflow (cfm/Ton)
445.7
Outside Air (%)
0.0
Outside Air (cfm/sqft)
0.00
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
CFM
I Sensible
1,143
17,770
266
326
13,701
0
888
685
0
0
0
0
0
0
0
0
0
888
685
19 547 266
HVAC EQUIPMENT SELECTION
BDP CO. 563AN036-A 21,983 10,262
Total Adjusted System Output 21 983 10,262
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm
56,000
56,000
Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0°F 69.5°F 69.5°F 109.7°F
.1 00W Supply Air Ducts
Outside Air
0 cfm Supply Fan Heating Coil 109.2 °F
1300 cfm ROOMS
70.0 OF
69.5 °F
f% Return Air Ducts 4
ratures at Time of Cooli
11.0/77.4°F 78.6/67.0°F 78.6/66.9°F 62.9/61.8°F
i!^
Outside Air
0 cfm
78.6/67.0 ° F
Supply Fan Cooling Coil
1300 cfm
K Return Air Ducts `i
Supply Air Ducts
63.5 / 62.0 OF
56.1% R. H. ROO6+c
78.0/66.8°F
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:19 of 23
ROOM LOAD SUMMARY
PROJECT NAME
Sibert Residence
DATE
8/24/2004
SYSTEM NAME
Second Floor
FLOOR AREA
389
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Second Floor
Second Floor
1
376
5,559
181
376
5,559
181
98
3,991
PAGE TOTAL 1 376 5,559 181 98 3,991
TOTAL 1 376 5,559 18111 98 3,991
EnergyPro 3.1 By EnergySofl User Number: 2655 Job Number: Page:20 of 23
ROOM LOAD SUMMARY
PROJECT NAME
Sibert Residence
DATE
8/24/2004
SYSTEM NAME
Zone 1
FLOOR AREA
1,225
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 1
Zone 1
1
1,952
29,585
3,156
1,952
29,585
3,156
648
27,215
PAGE TOTAL
TOTAL
1 1,952
29,585
3,156
648
27,215
1 1,952
29,585
3,156
648
27,215
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:21 of 23
ROOM LOAD SUMMARY
PROJECT NAME
Sibert Residence
DATE
8/24/2004
SYSTEM NAME
Zone 3
FLOOR AREA
1,224
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 3
Zone 3
1
1,124
17,352
569
1,124
17,352
569
485
20,159
PAGE TOTAL 1 1,124 17,352 569 485 20,159
TOTAL 1 1,124 17,352 56911 485 20,159
EnergyPro 3.1 By EnergySoft User Number: 2655 Job Number: Page:22 of 23
ROOM LOAD SUMMARY
PROJECT NAME
Sibert Residence
DATE
8/24/2004
SYSTEM NAME
Zone 2
FLOOR AREA
572
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Zone 2
Zone 2
1
1 143
17,770
266
1,143
17,770
266
326
13,701
PAGE TOTAL 1 1,143 17,770 266 326 13,701
TOTAL 1 1,143 17,770 266 326 13,701
EnergyPro 3.1 By EnergySofl User Number: 2655 Job Number: Page: 23 of 23