Loading...
BPOL2022-0214Description: TOLL BROTHERS / POOL AND SPA AT REAR YARD Type: POOL CONSTRUCTION Subtype: PRIVATE Status: FINALED Applied: 5/23/2022 ECON (WEB) Approved: 6/21/2022 AOR Parcel No: 762440002 Site Address: 80394 OLD RANCH TRL NORTH LA QUINTA,CA 92253 Subdivision: TR 30834 Block: Lot: 21 Issued: 6/22/2022 AHI Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 11/18/2022 MHU Valuation: $15,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: POOL AND SPA AT REAR YARD [PATRELL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION. TWO DROWNING SAFETY FEATURES AND THE ADDITIONAL POOL BARRIER ARE REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODE. 149- 29 1 I Applied to Approved Approved to Issued Issued to Finaled Printed: Friday, April 28, 2023 2:10:23 PM 1 of 5 WSYSiEMS CHRONOLOGY • NAME TYPE NAME ADDRESSICITY STATE ZIP PHONE FAX EMAIL APPLICANT TESERRA P O BOX 1280 COACHELLA CA 92236 KEVING@TESERRAOUT DOORS.COM CONTRACTOR TESERRA P O BOX 1280 COACHELLA CA 92236 KEVING@TESERRAOUT DOORS.COM OWNER TOLL LAND XXII LTD PARTNERSHIP 725 W TOWN AND COUNTRY RD STE 200 ORANGE CA 92868 Printed: Friday, April 28, 2023 2:10:23 PM 1 of 5 WSYSiEMS Printed: Friday, April 28, 2023 2:10:23 PM 2 of 5 WsYsrEMS ■ ■ CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 6/22/22 R71006 171798 CHECK TESERRA AHI Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA. SWIMMING POOL/SPA/WATER 101-0000-42404 0 $208.41 $208.41 6/22/22 R71006 171798 CHECK TESERRA AHI FEATURE SWIMMING POOL/SPA/WATER 101-0000-42600 0 $113.38 $113.38 6/22/22 R71006 171798 CHECK TESERRA AHI FEATURE PC Total Paid for POOL / SPA 2021: $321.79 $321.79 RECORDS 101-0000-424160 $11.00 $11.00 6/22/22 R71006 171798 CHECK TESERRA AHI MANAGEMENT FEE Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY 502-0000-436110 $5.00 $5.00 6/22/22 R71006 171798 CHECK TESERRA FAH ENHANCEMENT FEE Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE 9/26/2022 11:06 AM TESERRA Contact Name: TESERRA eTRA Inspection BOND BEAM BLD Site Address: 80394 OLD RANCH TRL NORTH Re Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM Printed: Friday, April 28, 2023 2:10:23 PM 2 of 5 WsYsrEMS Printed: Friday, April 28, 2023 2:10:23 PM 3 of 5 WsYsrEMS 7/20/2022 3:25 PM TESERRA Contact Name: TESERRA Site Address: 80394 OLD RANCH TRL NORTH Phone:7603899222 PRE-GUNITE MHU 7/21/2022 7/21/2022 DISAPPROVE eTRAKiT Inspection a -Mail: KEVING@TESERRAOUTDOORS.COM D Request EQUIPOTENTIAL BONDING REQUIRES 4 POINTS OF CONNECTION EVENLY SPACED AROUND THE POOL, THE NORTH SIDE OF POOL HAS NO BONDING WHIP 7/22/2022 2:19 PM TESERRA Contact Name: TESERRA PRE-GUNITE MHU 7/25/2022 7/25/2022 APPROVED eTRAKiT Inspection Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM 9/15/2022 3:19 PM TESERRA Contact Name: TESERRA UNDERGROUND PLBG MHU 9/16/2022 9/16/2022 APPROVED eTRAKiT Inspection Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM 9/15/2022 3:19 PM TESERRA Contact Name: TESERRA UNDERGROUND GAS MHU 9/16/2022 9/16/2022 APPROVED eTRAKiT Inspection Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM Printed: Friday, April 28, 2023 2:10:23 PM 3 of 5 WsYsrEMS PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS DATE REMARKS NOTES 1ST BLDG NS - MARK HUNT 5/23/2022 5/24/2022 ETRAKIT (1 DAY) 9/15/2022 3:19 PM TESERRA APPROVED BY MHU, PERMIT LOGGED BY AOR. eTRAKiT Inspection Contact Name: TESERRA UNDERGROUND ELEC MHU 9/16/2022 9/16/2022 APPROVED Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM 9/26/2022 1:58 PM TESERRA eTRAKiT Inspection Contact Name: TESERRA DECK BOND MHU 9/27/2022 9/27/2022 APPROVED Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM 10/5/2022 11:12 AM TESERRA Contact Name: TESERRA PRE -PLASTER MHU 10/6/2022 10/6/2022 APPROVED eTRAKiT Inspection Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603899222 e -Mail: KEVING@TESERRAOUTDOORS.COM 11/17/2022 2:32 PM TESERRA Contact Name: TESERRA FINAL" MHU 11/18/2022 11/18/2022 APPROVED eTRAKiT Inspection Site Address: 80394 OLD RANCH TRL NORTH Request Phone:7603409000 e -Mail: KEVING@TESERRAOUTDOORS.COM PARENT PROJECTS Printed: Friday, April 28, 2023 2:10:23 PM 4of5 CRWSYSTEMS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS DATE REMARKS NOTES 1ST BLDG NS - MARK HUNT 5/23/2022 5/24/2022 ETRAKIT (1 DAY) 6/21/2022 APPROVED APPROVED BY MHU, PERMIT LOGGED BY AOR. Printed: Friday, April 28, 2023 2:10:23 PM 4of5 CRWSYSTEMS Printed: Friday, April 28, 2023 2:10:23 PM 5 of 5 WsYsrEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 6/21/2022 AJ ORTEGA SITE PLAN (APPROVED) BPOL2022-0214 - SITE 1 PLAN (APPROVED).pdf DOC 5/23/2022 Etrakit Contractor Stone Creek lot 21.pdf 0 Printed: Friday, April 28, 2023 2:10:23 PM 5 of 5 WsYsrEMS • NO EXISTING LANDSCAPE LIGHTING IN REAR YARD NO EXISTING OVERHEAD UTILITY LINES IN REAR YARD ` PATIO FURNITURE FOR ILLUSTRATION PURPOSES ONLY RAISED SPAAT Or NTH 15' WIDE NATURAL GRAY BROOM FINISH CAP, TILE VENEER EXTERIOR, (6) HYDROTHERAPY JETS AT ALTERNATE HEIGHTS, 24" TILE LIP SPILLWAY 15' WIDE NATURAL GRAY BROOM FINISH COPING AROUND POOL SR. SMITH ARTISAN SERIES DECK TO DECK HANDRAIL TANNINGS ELF AT 12" WATER DEPTH WITH TWO UMBRELLA SLEEVE POOL/SPAUGHTJUNCTIONBOX POOL / SPA LIGHT ON GROUND FAULT CIRCUIT INTERRUPTER TRANSFORMER SPAAIR UNE POOL EQUIPMENT SD AMP SUBPANEL WITH 36" CLEARANCE AT FRONT AND SIDE ELECTRIC COMMIT POOL EQUIPMENT: 260,000 BTU HEATER "ALL EQUIPMENT SHALL BE SEISMICALLY ANCHORED 3T-11" POLYPROPYLENE GAS APE EXISTING 5'-0"H BLOCK WALL EXISTING 5'-O'H SELF LATCHING/SELF CLOSING GATE OPENING OUT GAS METER MAIN HOUSE 200 AMP ELECTRICAL PANEL INSTALLATION OF POOL SYSTEMS ANO EQUIPMENT WILL COMPLY WITH SECTION 114 -MANDATORY REQUIREMENTS EXIT ALARMS TO BE INSTALLED ON ALL DOORS WITH DIRECT ACCESS TO THE POOL POOL HEATERS / PUMP EQUIPMENT SHALL BE INSTALLED PER MANUFA RECOMMENDATIONS AND IN ACCORDANCE WITH LOCAL REGULATIONS ALLDECKING EXPANSION JOINTS FOR REPRESENTATION ONLY, FIELD LAYOUT WILL VARY t PL POOL SPUT MAIN DRAIN SUCTION MINIMUM 3' APART. ANTI -COVERS IO"ASME/ANSI APPROVED MEWILLE PLANK PAVERS SAND SET OVER H-4” CLASS II ROAD BASE AND H-1" BEDDING SAND, MUD SET PERIMETER PAVER, COLOR T.&D. ��.Ff. _ Ff. POOLCOPINO BPOL2022-0214 CITY OF LA QUINTAf BUILDING LXVISION REWEWEDFOR CODE COMPLIANCE x, A AJy„ o.�. A9RIms POOL AND SPA AT REAR YARD IPATRELL ENGINEERING] THIS PERMIT DOES NOT INCLUDE EQUIPMENT ENCLOSURE. WET STAMPED POOL ENGINEERING SHEET REQUIRED TO BE ONSITE FOR INSPECTION, TWO DROWNING SAFETY FEATURES AND THE ADDITIONAL POOL BARRIER ARE REQUIRED TO BE EXI,TING 5'-0'H BLCCK INSTALLED AT WALL PRE -PLASTER INSPECTION. 2019 CALIFORNIA BUILDING CODE. TgIJNDY 9� eb 9pR. oR�.Ra wA0@DO�LE c- E HSC gWE r'E CO • �°°u ^°x^rauexn u+xmo uv..oxuomur,a.urwm.xowawnneiaeomnux. E STONE CREEK RANCH LOT 21 COMMUNDY STONE [REEK R M—DRUS 90-394 OLD RNSH TRAIL HBtTH ­AQUI QUI HOMEOWNER MONLE HOMEONMER EMNL PROJECT MANAGER MOBILE )00289-9214 PROIECTMANAGERGANL ka4n5Qlemerraaut UBTOMER NUMBER: &CNE WTE DESIGNED BY I- ROJECTING-0S98R KEMN B. -0— REVISIONS 1 _ TOEUMRQE�I„,� 2019 eO RI 20, 9 eA :Niro eU_ Ho ec101 2019 CALIFORNIA NreCNANIe e(eumaxmleuRcl 2019 CALIFORNIA PLUMNING uFl . 20, 9 CALIFORNIA RLECTRICA zaz I 2019 CALIFORNIANERCY aCo.. 2019 CALIFCIRNIA ENERGY 2 S 4 5 s;a 8 SELECTIONS CONSTRUCTION AUTHORIZATION STONE 'EBBIPUS IOULOERS DRAINAGE xoTE: 12