Loading...
BWFE2022-0073Description: TOLL BROS/253LF OF 6' GARDEN WALL AT EAST AND WEST PROPERTY Type: WALL/FENCE (WEB) Subtype: CITY STANDARD/PRE- Status: ISSUED Applied: 2/24/2022 ECON APPROVED Approved: 3/17/2022 JAN Parcel No: 762440002 Site Address: 80394 OLD RANCH TRL NORTH LA QUINTA,CA 92253 Subdivision: TR 30834 Block: Lot: 21 Issued: 3/31/2022 AOR Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $14,674.00 Occupancy Type: Construction Type: Expired: 3/31/2023 AOR No. Buildings: 0 No. Stories: 0 No. Unites: 0 ADDRESSI Details: TOLL BROS/253LF OF 6' GARDEN WALL AT EAST AND WEST PROPERTY LINES.[ ORCO SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA BUILDING CODES. CHRONOLOGY CONDITIONS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT TOLL BROS INC DBA TOLL BROS IN 1140 VIRGINIA DR HORSHAM PA 19034 (215)938-8000 AJANISCH@TOLLBROT HERS.COM CONTRACTOR TOLL BROS INC DBA TOLL BROS IN 1140 VIRGINIA DR HORSHAM PA 19034 (215)938-8000 AJANISCH@TOLLBROT HERS.COM OWNER TOLL LAND XXII LTD PARTNERSH 50400 JEFFERSON ST I LA QUINTA CA 92253 (215)938-8000 ajanisch@tollbrothers. com Printed: Friday, April 28, 2023 2:12:30 PM 1 of 4 WSYSiEMS DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY WALL/FENCE - EA 101-0000-42404 0 $66.68 $66.68 3/31/22 WEB11210 636301075 CREDIT 777699 ECON ADDITIONAL 50LF 71 WALL/FENCE - FIRST 636301075 101-0000-42404 0 $55.58 $55.58 3/31/22 WEB11210 CREDIT 777699 ECON 100LF 71 WALL/FENCE - FIRST 636301075 101-0000-42600 0 $69.47 $69.47 3/31/22 WEB11210 CREDIT 777699 ECON 100LFPC I I I I I 1 171 Total Paid for BLOCK WALL 2021: $191.73 $191.73 BSAS SB1473 FEE 101-0000-203060 $1.00 $1.00 3/31/22 WEB11210 636 01075 CREDIT 777699 ECON 71 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: RECORDS 101-0000-424160 $11.00 $11.00 3/31/22 WEB11210 636301075 CREDIT 777699 ECON MANAGEMENT FEE 71 Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 TECHNOLOGY 502-0000-436110 $5.00 $5.00 3/31/22 WEB11210 636301075 CREDIT 777699 ECON ENHANCEMENT FEE 71 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: $208.73 $208.73 SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES DATE DATE 7/21/2022 10:11 AM TOLL BROS INC DBA TOLL BROS INC PALM SPRINGS CA DIVISION Contact Name: TOLL BROS INC DBA TOLL FOOTINGS MHU 7/22/2022 7/22/2022 APPROVED eTRA Inspection BROS INC PALM SPRINGS CA DIVISION Re Request Site Address: 80394 OLD RANCH TRL NORTH Phone:2159388000 e -Mail: AJANISCH@TOLLBROTHERS.COM Printed: Friday, April 28, 2023 2:12:30 PM 2 of 4 WsYsrEMS PARENT PROJECTS JAM REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS DATE 8/10/2022 5:20 PM TOLL BROS INC DBA NOTES 1ST BLDG NS - ETRAKIT (1 DAY) JULIO ANAYA 2/24/2022 2/25/2022 3/17/2022 APPROVED TOLL BROS INC PALM SPRINGS CA DIVISION Contact Name: TOLL BROS INC DBA TOLL PARTIALLY eTRAKiT Inspection BROS INC PALM SPRINGS CA DIVISION BOND BEAM MHU 8/12/2022 8/12/2022 APPROVED Request Site Address: 80394 OLD RANCH TRL NORTH Phone:2159388000 e -Mail: AJANISCH@TOLLBROTHERS.COM PL ONLY 9/13/2022 2:42 PM TOLL BROS INC DBA TOLL BROS INC PALM SPRINGS CA DIVISION Contact Name: TOLL BROS INC DBA TOLL BOND BEAM MHU 9/14/2022 9/14/2022 APPROVED eTRAKiT Inspection BROS INC PALM SPRINGS CA DIVISION Request Site Address: 80394 OLD RANCH TRL NORTH Phone:2159388000 e -Mail: AJANISCH@TOLLBROTHERS.COM 9/14/2022 1:08 PM TOLL BROS INC DBA TOLL BROS INC PALM SPRINGS CA DIVISION Contact Name: TOLL BROS INC DBA TOLL BOND BEAM MHU 9/15/2022 9/16/2022 CANCELED eTRAKiT Inspection BROS INC PALM SPRINGS CA DIVISION Request Site Address: 80394 OLD RANCH TRL NORTH Phone:2159388000 e -Mail: AJANISCH@TOLLBROTHERS.COM PARENT PROJECTS JAM Printed: Friday, April 28, 2023 2:12:30 PM 3 of 4 WsYsrEMS REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED STATUS DATE REMARKS NOTES 1ST BLDG NS - ETRAKIT (1 DAY) JULIO ANAYA 2/24/2022 2/25/2022 3/17/2022 APPROVED Printed: Friday, April 28, 2023 2:12:30 PM 3 of 4 WsYsrEMS Printed: Friday, April 28, 2023 2:12:30 PM 4 of 4 WsYsrEMS ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 2/24/2022 Etrakit Contractor 1'ST SUBMITTAL SITE Lot 21.pdf 1 PLAN DOC 3/17/2022 JULIO ANAYA SITE PLAN (APPROVED) BWFE2022-0073 - SITE 1 PLAN (APPROVED).pdf Printed: Friday, April 28, 2023 2:12:30 PM 4 of 4 WsYsrEMS LEGEND 4 R,V� NOTE: DIMENSIONS SHOW FACE AND NOT ARCHITEC' BWFE2022-0073 P/L Cl N OF LA QU N TA BU LEI N GCI VI S CN REM EYED FCR CCCE COWU AV CE Em J.ANAYA ice: 0311712022 ARE TO BUILDING P/L P/L TOLL BROS/253LF OF 6' GARDEN WALL AT EAST AND WEST PROPERTY LINES. [ ORCO SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE 'RECISE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE RS NOT CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA RUCTION 'BUILDING CODES. MSA CONSULTING, INC.TOLL BROTHERS / STONE CREEK RANCH OCTOBER 2021 > PLANNING Drive, ENGINEERING LAND SURVEYING TRACT NO. 30834 34200 Bob Hope Drive, Rancho Mirage, CA 922 270 760.320.98„ msaconsultinginacom LOT 21 - OLD RANCH TRAIL NORTH LOT AREA 1 1,053 SF ADDRESS: LA QUINTA, RIVERSIDE COUNTY, CALIFORNIA BUYER'S ACCEPTANCE DATE: PROPERTY LINE EXISTING BOUNDARY EXISTING EASEMENT R. EXISTING RIGHT OF WAY CABLE ELECTRIC GAS TELEPHONE SEWER WATER GARDEN WALL STEEL VIEW FENCE GARDEN WALL W/ VIEW FENCE COMBO RETAINING /GARDEN WALL �.nP � TOP OF SLOPE OE TOE OF SLOPE ❑® AIR CONDITIONING PAD CONCRETE DOOR/GATE FIRE HYDRANT WATER METER S SEWER LATERAL 4 R,V� NOTE: DIMENSIONS SHOW FACE AND NOT ARCHITEC' BWFE2022-0073 P/L Cl N OF LA QU N TA BU LEI N GCI VI S CN REM EYED FCR CCCE COWU AV CE Em J.ANAYA ice: 0311712022 ARE TO BUILDING P/L P/L TOLL BROS/253LF OF 6' GARDEN WALL AT EAST AND WEST PROPERTY LINES. [ ORCO SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE PROPERTY. THE AREA BETWEEN THE BACK OF CURB AND ANY FENCING SHALL BE 'RECISE LANDSCAPED, HAVE A SUITABLE PERMANENT IRRIGATION SYSTEM, AND BE RS NOT CONTINUOUSLY MAINTAINED BY THE PROPERTY OWNER. 2019 CALIFORNIA RUCTION 'BUILDING CODES. MSA CONSULTING, INC.TOLL BROTHERS / STONE CREEK RANCH OCTOBER 2021 > PLANNING Drive, ENGINEERING LAND SURVEYING TRACT NO. 30834 34200 Bob Hope Drive, Rancho Mirage, CA 922 270 760.320.98„ msaconsultinginacom LOT 21 - OLD RANCH TRAIL NORTH LOT AREA 1 1,053 SF ADDRESS: LA QUINTA, RIVERSIDE COUNTY, CALIFORNIA BUYER'S ACCEPTANCE DATE: ORCO STANDARD CMU SITE WALLS W/ TRENCH FOOTING FOR 110 MPH 3 SEC. GUST Cad EXP C REBAR NOTE: • DO NOT RUN HORIZONTAL REINFORCEMENT THROUGH WALL RETURNS & CONSTRUCTION JOINTS. • PROVIDE DOWEL & DROP-IN BAR ACCORDING TO DETAIL AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES. w 0 00 N CAP UNIT DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF t 3 SEISMIC/WIND PER SOILS REPORT. 2. EQUIVALENT FLUID PRESSURE = 45 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 300 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION = 60% PER SOILS REPORT. 7. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. ORCO 6816 OR 6616 CMU GROUTED ONLY @ VERT STEEL #4 - DROP-IN BAR @ 40" O/C @ CENTER OF CMU #6 STD JOINT REINFORCEMENT @ 24" O/C (3 PLACES). USE #5 STD. FOR SLUMP BLOCK NOTE: FOR SIDEYARD RETURN WALLS WHERE DRAINAGE SWALE OCCURES, A 1/2 BLOCK MAY LEFT OUT @ SWALE GRADE. PROVIDE #4 DOWEL AND #4 DROP-IN BAR ON EACH SIDE OF THE 1/2 BLOCK DRAIN. #4 DOWEL @ 40" O/C @ CENTER OF CMU. PROVIDE 24" MIN. LAP. Z 17 V M #4 HORZ. CONTT, 6' MIN. TO DAYLIGHT 8" CONT. NOTE: DIMENSIONS ARE NOT TO SCALE. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. SLUMP BLOCK AND SPLITFACE BLOCK ARE ACCEPTABLE. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL BLOCK CELLS CONTAINING VERTICAL REBAR SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10, FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11. FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12. MAXIMUM CONTROL JOINT SPACING: 40'01C OR 20'01C IF THE WALL IS TO BE STUCCO COATED. TOLL BROTHERS STONE CREEK RANCH TRACT No. 30834 LA QUINTA, CALIFORNIA DETAIL #1 ORCO 6' WALL WITH RETAINING & TRENCH FOOTING FOR 110 MPH WIND 3 SEC. GUST C) EXP C f CAP UNIT NOTE: PROVIDE #4 DOWEL & #4 DROP-IN BAR AT EACH SIDE OF CONTROL JOINTS, ENDS OF WALLS AND @ WALL HEIGHT CHANGES ORCO 6816 OR 6616 CMU GROUTED ONLY @ VERT STEEL #4 VERT DROP-IN BAR @ 32" O/C PROVIDE 24" LAP INTO 8" CMU k � #6 STD JOINT REINFORCEMENT @ 24" O/C (3 PLACES). USE #5 m STD. FOR SLUMP BLOCK SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRY STEM. #4 HORZ CONT. @ 24" O/C LEVEL BACKFILL COMPACTED TO MIN. 90% COMPACTION PER ASTM 1557-D DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF + i SEISMIC/WIND. 2. EQUIVALENT FLUID PRESSURE = 45 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 300 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION = 60% PER SOILS REPORT. 7. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. SLUMP BLOCK AND SPLITFACE BLOCKARE ACCEPTABLE. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11, FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12, MAXIMUM CONTROL JOINT SPACING: 40'01C OR 20'01C IF THE WALL IS TO BE STUCCO COATED. DETAIL #2 'A' 'D' Z 2" CLR. #4032" 0/C 2x'DO DAYLIGHT 10" CONT O • X' DOWEL � V PROVIDE 4"DIA. SDR 35 Q PERF PIPE W11 FT WIDE Z OF 4 TO 1 " GRAVEL WRAPPED W1 MIRAFI 140N p- FILTER FABRIC TO WITHIN 1 FT OF FG - SLOPE TO Op DRAIN. WATERPROOF 0 r � / BACKSIDE OF RETAINING WALL. #4 HORZ. CONT. @18" O/C DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF + i SEISMIC/WIND. 2. EQUIVALENT FLUID PRESSURE = 45 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 300 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION = 60% PER SOILS REPORT. 7. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. SLUMP BLOCK AND SPLITFACE BLOCKARE ACCEPTABLE. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11, FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12, MAXIMUM CONTROL JOINT SPACING: 40'01C OR 20'01C IF THE WALL IS TO BE STUCCO COATED. DETAIL #2 'A' 'D' Z � v #4032" 0/C 2x'DO DAYLIGHT 10" CONT DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF + i SEISMIC/WIND. 2. EQUIVALENT FLUID PRESSURE = 45 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 300 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION = 60% PER SOILS REPORT. 7. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. SLUMP BLOCK AND SPLITFACE BLOCKARE ACCEPTABLE. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2" INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10. FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11, FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12, MAXIMUM CONTROL JOINT SPACING: 40'01C OR 20'01C IF THE WALL IS TO BE STUCCO COATED. DETAIL #2 'A' 'D' 'X' DOWEL #4032" 0/C #4032" 0/C TOLL BROTHERS STONE CREEK RANCH TRACT No. 30834 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE. ORCO RETAINING WALL WITH LEVEL BACKFILL SPECIAL INSPECTION NOTE: PROVIDE LEVEL 2 SPECIAL INSPECTION PER TMS 602-16 TABLES 3 & 4 OF THE MASONRY STEM. v � 14 HORZ CONT. @ 12" O/CAS SHOWN. 6" I. 12" B' DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF + 17 SEISMIC/WIND. 2. EQUIVALENT FLUID PRESSURE = 45 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 300 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION = 60% PER SOILS REPORT. 7. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. 'HT' WALL PER 'C' DETAIL #1 NOTE: PROVIDE DOWEL & A'4 DROP-IN BAR A A T EACH OR #2 SIDE OF CONTROL JOINTS, 4" ENDS OF WALLS AND @ WALL N/A HEIGHT CHANGES ol 2'-9" MIN. OPTIONAL CAP 2'-8" V-9" LEVEL BACKFILL #4@32" 0/C4/" J COMPACTED TO MIN. 90% COMPACTION #4 HORZ CONT. PER ASTM 1557-D @ 24" O/C #4@32" 0/C J49" #4@32" 0/C /5" IF I'D uj CL W Z O D' DOWEL00 4'-0" k OCK Q eC-1 g l'-0" lo b PROVIDE 4"DIA. SDR 35 OPERF PIPE W1 SFT WIDE U OF 4 TO 1"GRA VEL D W1 AFI 14OTHIN /8„ FABRIC FILTER FABRIC TO WITHIN FILTER T 3'-3" 1 FT OF FG - SLOPE TO #4@l6" 0/C165" DRAIN. WATERPROOF • BACKSIDE OF RETAINING WALL. N ti • 'E' BAR 3" CLR. v � 14 HORZ CONT. @ 12" O/CAS SHOWN. 6" I. 12" B' DESIGN CRITERIA PER THE 2019 CBC: 1. ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF + 17 SEISMIC/WIND. 2. EQUIVALENT FLUID PRESSURE = 45 PCF. 3. ALLOWABLE LATERAL PASSIVE PRESSURE = 300 PCF PER SOILS REPORT. 4. GROUT STRENGTH = 2000 PSI @ 28 DAYS. 5. REINFORCING STEEL : GRADE 60. 6. SEISMIC - 1 SEC. ACCELERATION = 60% PER SOILS REPORT. 7. MASONRY COMPRESSION STRENGTH f 'm = 2000 PSI. 'HT' 'B' 'C' 'D' DOWEL 'E' BAR 2'-0" V-6" 4" #4@32" o/81 N/A —j33" 2'-8" V-9" 6" #4@32" 0/C4/" J N/A 8„ #4@32" 0/C J49" #4@32" 0/C /5" 4'-0" 2'-9" l'-0" #4@16" 0/C57" #4@l6" 0/C 2/" 8„ /8„ 4'-8" 3'-3" V-2" #4@l6" 0/C165" #4@l6" O/C 27" 8"-] F GENERAL NOTES: 1. CONCRETE BLOCK SHALL BE MANUFACTURED BY ORCO ASTM C 90. SLUMP BLOCK AND SPLITFACE BLOCK ARE ACCEPTABLE. 2. CONCRETE FOR FOOTING SHALL BE 1 PART CEMENT TO 2-1/2 PARTS SAND TO 3-1/2 PARTS GRAVEL WITH A MAXIMUM OF 1-1/2 GALLONS OF WATER PER SACK. PORTLAND CEMENT SHALL CONFORM TO ASTM C 150 TYPE II/V. Fc = 2500 PSI 3. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A 615 GRADE 60. PROVIDE 48 BAR DIAMETER LAP. 4. REBAR SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED. 5. CONCRETE BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN WITH VERTICAL CONTINUITY OF THE CELLS UNO. 6. ALL RETAINING WALL BLOCK CELLS SHALL BE SOLID GROUTED. 7. USE TYPE S MORTAR PROPORTIONED USING ASTM C 270 PART CEMENT TO 1/2 PART LIME TO 4-1/2 PARTS DAMP, LOOSE SAND. 8. GROUT FOR CONCRETE BLOCK PER ASTM C 476 TO BE 1 PART CEMENT TO 3 PARTS SAND (GROUT MAY CONTAIN 2 PARTS 3/8" PEA GRAVEL IF WEATHER CONDITIONS ARE FAVORABLE AND BLOCK UNOBSTRUCTED CELL SIZE IS SUFFICIENT TO ALLOW GOOD GROUT FLOW). WATER SHALL BE ADDED TO PRODUCE GOOD GROUT FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. 9. BLOCK STEM MAY BE WET -SET 1-1/2"INTO THE FOOTING WHILE THE CONCRETE IS PLASTIC. BLOCK STEM MAY BE PLACED TO EITHER EDGE OF THE TRENCH TYPE FOOTING. 10, FOOTING MUST BE POURED ON OR INTO UNDISTURBED NATURAL SOIL OR ON COMPACTED FILL WITH A MINIMUM COMPACTION OF 90%. 11, FIRST INSPECTION TO BE AFTER FOOTING TRENCHES ARE READY FOR CONCRETE AND ALL REQUIRED STEEL IS TIED IN PLACE. SECOND INSPECTION TO BE WHEN THE REQUIRED VERTICAL IS IN PLACE AND THE BLOCK WALL IS READY TO GROUT. 12, MAXIMUM CONTROL JOINT SPACING: 40'01C OR 20'01C IF THE WALL IS TO BE STUCCO COATED. ENGINEERING STAMP APPROVAL IS CONDITIONAL; REQUIRING USE OF ORCO MANUFACTURED CMU ON ALL ORCO WALL SYSTEM DESIGNS. DETAIL #3 PRU, — I ON �EFtDU Lu Q o�2��02� m N0. 83660 D * EXP. 03/3//2023 PT9T C / v 1 \- ��\P F o OF CA0� TOLL BROTHERS STONE CREEK RANCH TRACT No. 30834 LA QUINTA, CALIFORNIA NOTE: DIMENSIONS ARE NOT TO SCALE.