Loading...
BRES2020-0329 Geotechnical Report*Sladden Engineering 45090 Golf Center Parkway, Suite 1{, Indio, CA 92201 (760) 863-0713 6782 Stanton Avenue, Suite C, Buena Park, CA 90621 (714) 523-0952 450 Egan Avenue, Beaumont, CA 92223 (951) 845-7743 www.Sladdenengineering.com October 22, 2020 Discovery Builders California, Inc. 53965 Humboldt Boulevard La Quinta, California 92253 Subject: Geotechnical Update Project No. 544-20342 20-10-536 BRES2020-0329 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE03/30/2021 ev JF Project: Proposed Custom Residence 53804 Ross Avenue 15,847SF S.F.D. The Madison Club La Quinta, California Ref: Geotechnical Investigation report prepared by Sladden Engineering dated January 28,2005; Project No. 544-4810, Report No. 05-01-101 Report of Testing and Observation During Rough Grading prepared by Sladden Engineering dated March 2, 2006; Project No. 522-4810; Report No. 06-02-120 In accordance with your request, we have reviewed the above referenced geotechnical reports as they relate to the design and construction of the proposed custom residence to be constructed on the subject site located at 53804 Ross Avenue within the Madison Club development in the City of La Quinta, California. It is our understanding that the proposed residential structure will be of relatively lightweight wood -frame construction and will be supported by conventional shallow spread footings and concrete slabs on grade. The referenced reports include recommendations pertaining to the design and construction of residential structure foundations. The previous reports also address the potential for liquefaction, subsidence and differential settlement. Based upon our review of the referenced reports, it is our opinion that the structural values included in these reports remain applicable for the design and construction of the proposed residential structure foundations. The allowable bearing pressures recommended in the referenced Geotechnical Investigation report remain applicable. Conventional shallow spread footings should be bottomed into properly compacted fill material a minimum of 12 inches below lowest adjacent grade. Continuous footings should be at least 12 inches wide and isolated pad footings should be at least 2 feet wide. Continuous footings and isolated pad footings should be designed utilizing allowable bearing pressures of 1500 psf and 2000 psf, respectively. Allowable increases of 300 psf for each additional 1 foot of width and 300 psf for each additional 6 inches of depth may be utilized, if desired. The maximum allowable bearing pressure should be 3000 psf. The recommended allowable bearing pressures may be increased by one-third for wind and seismic loading. Sladden Engineering October 22, 2020 -2- Project No. 544-20342 20-10-536 Lateral forces may be resisted by friction along the base of the foundations and passive resistance along the sides of the footings. A friction coefficient of 0.48 times the normal dead load forces is recommended fox use in design. Passive resistance may be estimated using an equivalent fluid weight of 300 pcf. If used in combination with the passive resistance, the frictional resistance should be reduced by one third to 0.33 times the normal dead load forces. The bearing soil is generally non -expansive and falls within the "very low' expansion category in accordance with the 2019 (CBC) classification criteria. Slab thickness and reinforcement should be determined by the Project Structural Engineer. We recommend a minimum floor slab thickness of 4.0 inches and minimum reinforcement of M3 bars at 24 inches on center in both directions. All slab reinforcement should be supported on concrete chairs to ensure that reinforcement is placed at slab mid -height. Slabs with moisture sensitive surfaces should be underlain with a moisture vapor retarder consisting of a polyvinyl chloride membrane such as 10 -mil visqueen, or equivalent. All laps within the membrane should be sealed and at least 2 inches of clean sand should be placed over the membrane to promote uniform curing of the concrete. To reduce the potential for punctures, the membrane should be placed on a pad surface that has been graded smooth without any sharp protrusions. If a smooth surface cannot be achieved by grading, consideration should be given to placing a 1 -inch thick leveling course of sand across the pad surface prior to placement of the membrane. The seismic design category for a structure may be determined in accordance with Section 1613 of the 2019 CBC or ASCE?-16. According to the 2019 CBC, Site Class D measured may be used to estimate design seismic loading for the proposed structures with sufficient understanding of the subsurface conditions. The 2019 CBC Site Specific Seismic Hazard Analyses are attached. The subject lot was previously graded during the rough grading of the Madison Club project site. The rough grading included over -excavation and re -compaction of the native surface soil along with the placement of engineered fill material to construct the building pads. The site grading is summarized in the referenced report of Testing and Observation During Rough Grading along with the compaction test results. Because the lot has been previously rough graded, the remedial grading required at this time should be minimal provided that the building area falls within the previously assumed building envelope. The building areas should be cleared of surface vegetation, scarified and moisture conditioned prior to precise grading. The exposed surface should be compacted to a minimum of 90 percent relative compaction prior to fill placement. The previously removed soil and any fill material should be placed in thin lifts at near optimum moisture content and compacted to at least 90 percent relative compaction. Sladden Engineering October 22, 2020 -3- Project No.544-20342 20-10-536 We appreciate the opportunity to provide service to you on this project. If you have any questions regarding this letter or the referenced reports,. please contact the undersigned. Respectfully submitted, SLADDEN ENGINEERING Brett L. Anderso AND@R90N Principal Engineer C7 No. 045389 � CNIL it ENGINEERING s SER/ra T'9T,� _ ,,nF Copies: 4/Discovery Builders California, Tnc. .. gg`" - Ja Minor III a JAMES W S for Geologist MINOR III No. 9735 N�, ATF OF CA��F Sladden Engineering 5 �{I- - Z03 L(2. Please verify that soils reports contain all of the above Information. in addition, to assure continuity between the investigation/reporfing stage and the execution stage, please use the following checklist to verify that the conclusions and recommendations in the report cover all the required elements. Only then can we be assured that the construction documents address all of the site soil conditions. La Qulnta Geotechnical Report Checklist Does the "Conclusions and Recommendations" section of the report address each of the following criteria? "Address" means. (a) the criterion is considered significant and mitigation measure(s) noted, or; (b) the criterion is considered insignificant and explicitly so stated. Yds .No Criterion C] ❑ Foundation criteria based upon bearing capacity of natural or compacted soil. [l/ ❑ Foundation criteria to mitigate the effects of expansive sobs. t� ❑ Foundation criteria based upon bearing capacity, of natural or compacted soil. l_I ❑ Foundation criteria to mitigate.the effects of liquefaction. t[I ❑ Foundation criteria to mitigate the effects of seismically induced differential —/ settlement. - ' Lr ❑ Foundation criteria to mitigate the effects of long-term differential settlement. CC ❑ Foundation criteria to mitigate the effects of varying soil strength. ❑ Foundation criteria to mitigate expected total and differential setflement. Any "No" answers to the above checklist should be noted as specific required corrections. BRETT L. ANDERSON rr0. C45389 CNIL Project: Custom Residence <=0.2, Project Number: 544-20342 0.907 Client: Discovery Builders California, inc Site Let/Long: 3346582/-116.2479 Controlling Seismic Source: Southern San Andreas REFERENCE NOTATION VALUE Site Class C, D, D default, or E D measured Site Class D -Table 11.44 Fa 1.0 Site Class D - 21.3(11) F„ 2.5 0.2*(Sm/SDs) To 0.137 Sol/Sos Ts 0.686 Fundamental Period (12.8.2) T Period CRI Seismic Design Maps or Fig 22-14 Ti 8 Equation 11.4-4-2/3*SMI SDI 0,6857* Equation 11.4-2 - Fv*SI SMI 1.0285* Cr - At Perods <=0.2, Cr=Cas Cas 0.907 Cr -At Periods >=1,0, Cr=CRI CRI 0.89 " Cedo based desigro value. See accompanying data for Site Specific Design values. Sladden Engineering REFERENCE NOTATION VALUE Fv (Table 11.4-2)[Used for General Spectrum] Fv 1.7 Design Maps S, 1.500 Design Maps 51 0.605 Equation 11.4-1- FA*Ss SMS Equation11.4-3 - 2/3*SMs SOS -- Design Maps PGA 0.649 Table 11.8-1 FPGA 1.1 Equation 11.8-1- FPGA*PGA PGAM 14* Section 21.5.3 80% of PGAM 0.571 Design Maps Cas0.907 Design Maps CRI 0.89 Cr - At Periods between 0.2 and 1.0 Period Cr use trendline formula to complete 0.200 0.907 0.300 0.905 0.400 0.903 0.500 0.901 0.600 0.899 0.680 0.897 1.000 0.89 Mapped values from httos//seismicmaas.or PRO BABILISTICSPECr I 2% in 50 year Exceedence Period UGHM RTHM Max Directional Scale Factor' Probabilistic MCE 0.010 0.802 0.769 1.19 0.915 0.100 1.333 1.305 '1, 1r1 1.553 0.200 1.777 1.747 1.10 2.096 0.300 .2.041 1.939 1.22 2.366 0.500 2.033 1.872 1.23 2.303 0.750 1.686 1.532 1.24 1.900 1.000 1.445 1.286 7..74 1.595 2.000 0.834 0.739 1.24 0.916 3.000 0.573 0.505 1.15 0.631 4.000 0.423 0.371 1..'Z; 0.464 5.000 0.322 0.283 1.7.6 0,357 ProbabiAstic PGA: 0.802 IS ProbabjOsticSalm„151.2Fat_ NO Project No: 544-20342 'Data Sources: htt i//e nho k sas eov/hazards/interacive/ htt s://eanhouakeusaseoy/desixnmBRslrtem/ z 5hahi-Baker RotD100/RotD50 Factors (2014) Sladden Engineering MCER DETERMINISTIC SPECTRUM largest Amplitudes ot6raund Motiqns [onsitl¢dng All spurces Calculated using Weighted Mean of Attenuation Equattorrs' Canttolling Source: gouthem San Andreas IS Probabilistic Salm,y<1.2Fa1 NO Period Deterministic PSa Median+S.o for 9% Damping Max Directional Scale Factor! Deterministic MCE Section 21.2.2 Scaling Factor Applied 0.010 0.626 1.39 0.749 - - 0.020 0.628 1.19 0.748 .-�. 0.030 0.639 119 0.761 U.iul 0.050 0.683 1.19 0.813 U..;15 0.073 0.823 1.19 0.979 U:'%J 0.100 0.978 1.19 1.164 1.1 �,4 0.150 1.207 1.20 1.448 '�..•`1' O.ZOD 1.351 1.20 1.621 !���'�- 0.250 1.444 1.21 1.747 ;. x.1'1 0300 1.490 L22 1.818 l.�'x5 0.400 1.490 L23 1.833 ...... 0.900 1.434 1.23 1.764 .. �.. 0.760 1.194 1.24 1.430 -� . -1.!700 --096fi___.._ _.__.1.24_..___. _.. 1.197__ __ ��"_"_-__. 1500 O.fi94 1.24 0.861 �.,.o.. 2.000 0.529 1.24 0.657 U.i:S!' 3.000 0.363 1.29 0.454 ,�...� 4.D00 0.256 1.29 0.322 U.3:7 9A00 0.192 LZ6 0.242 ii2�l: 1.50 � � S.pO I¢ 050 0.00 0.000 Project No: 944-20342 Is Detennlnstic 9al�l<1.5"Fa7 NO Section 2LZ.25wling Factor. N/A Deterministic PGA: 0.626 Is Deterministic PGA>=Frw,"0.57 YE5 r NGAWest2GMPEworksheetand - - Ungorm Cal'rfarnta Earthquake Rupture Fomcas4 Version 3ftICERF31-Time pependemmpdel s Shahi-Baker Rotpi0o/RIND50 Factors (2019) Sladden Engineering L000 z.oa0 3.a0o a.000 s.00o Pertgd Isemnds) __ ___--.-- _ __ --�-D¢cermmiade MCER circ cocririr CPFCTRA Period Probabilistic MCE Deterministic MCE Site -Specific MCE Design Response Spectrum (Sa) 0.010 0.915 ,.- 0.745 - 0.100 1.553 0.030 1.164 - 0.200 2.096 0.908 1.621 1.636 0.300 2.366 I.;.1.<. 1.818 ..-.. -. 0.500 2.303 ;..:Ez, 1.764 ....-.... 0.750 1.900 0.705 1.430 -- - 1.000 1.595 _....-: 1.197 --- 2.000 0.916 b.5".7 0.657 _ 3.000 0.631 .:. _ 0.454 - 4.000 0.464 6.�-'___ 0.322 0.250 5.000 1 0.357 1 u.._'.'. 0.242 0.800 SDS: SDI: SMS: SM1: Site Specific PGAm: Site Class: ASCE 7-16: Section 21.4 Site Specific 0.422 Calculated 0.010 Design Value 0.020 Value 1.091 0.030 1.091 0. -5 0.908 0.619 0.908 0.060 1.636 0-`•�"-' 1.636 0.728 1.362 0.090 1.362 0.635 0.626 0.838 0.626 0.110 D measured 0.705 0.120 Seismic Design Category -Short* D SeismicDes ignCategory * Risk Categories I, II, or III Sladden Engineering Period ASCE 7 SECTION 11.4.6 General Spectrum 80% General Response Spectrum 0.005 0.422 0.010 0.444 0.020 0.488 0..'••:;u 0.030 0.531 0. -5 0.050 0.619 0.060 0.663 0-`•�"-' 0.075 0.728 0.090 0.794 0.635 0.100 0.838 0.670 0.110 0.881 0.705 0.120 0.925 0.740 0.136 0.995 0.79u - 50 - - - 1.000 0.800 0.160 1.000 0.800 0.170 1.000 0.800 0.180 1.000 4800 0.200 1.000 0.250 1.000 0. %'-6 0.300 1.000 0.800 0.400 1.000 0.800 0.500 1.000 0.800 0.600 1.000 0,800 0.640 1.000 0.800 0.680 1.000 0.800 0.850 0.807 0.645 0.900 0.762 0.609 0.950 0.722 0.577 1.000 0.686 0.549 1.500 0.457 0.366 2.000 0.343 0.27 � 3.000 0.229 0.183 4.000 0.171 0.137 5.000 0.137 X01%10 Project No: 544-20342 Slada9ana Engineering =Probabilistic MCE Deterministic MCE ma® Site -Specific MCE Design Response Spectrum —Df —ASCE 7 Section 11.4.6 General Spectrum •–..==g0%General Response Spectrum Project No: 54420342