Loading...
BRES2020-0329 Title 24CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis Calculation Date/Time: 2022-08-31T07:59:44-07:00 Input File Name: Lot 42A Madison Club.ribdl9x CF1R-PRF-01E (Page 1 of 23) GENERAL INFORMATION 01 Project Name Lot 42A Madison Club 02 Run Title Title 24 Analysis 03 Project Location 53-804 Ross Avenue 04 City La Quinta 05 Standards Version 2019 06 Zip code 92253 07 Software Version EnergyPro 8.1 08 Climate Zone 15 09 Front Orientation (deg/ Cardinal) 0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope NewConstruction 13 Number of Bedrooms 6 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 2 16 Existing Cond. Floor Area (ft) n/a 17 Fenestration Average U -factor 0.5 18 Total Cond. Floor Area (ft) 15847 19 Glazing Percentage (%) 20.89% 20 ADU Bedroom Count 0 21 ADU Conditioned Floor Area 0 22 Is Natural Gas Available? I Yes VALID ONLY FOR NEW PERMIT APPLICATIONS THROUGH DECEMBER 31, 2021 COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 10/03/2022 arm BRES2020-0329 - 53804 ROSS AVENUE REVISION 3 - ENERGY REPORT REVISION TO REFLECT SOLAR PV SYSTEM SIZE AND LAYOUT. REFER TO BSOL2022-0055. 2019 CALIFORNIA BUILDING CODES. Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE CF1R-PRF-01E Project Name: Lot 42A Madison Club Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 2 of 23) Calculation Description: Title 24 Analysis Input File Name: Lot 42A Madison Club.ribdl9x ENERGY DESIGN RATING 01 Energy Design Ratings Compliance Margins 04 Efficiency' (EDR) Total' (EDR) Efficiency' (EDR) Total' (EDR) Standard Design 35.7 19.1 3.09 Proposed Design 32.7 18.3 3 0.8 RESULT: 3: COMPLIES 1: Efficiency EDR includes improvements to the building envelope and more efficient equipment 2: Total EDR includes efficiency and demand response measures such as photovoltaic (PV) systems and batteries 3: Building complies when efficiency and total compliance margins are greater than or equal to zero • Standard Design PV Capacity: 16.09 kWdc REQUIRED PV SYSTEMS - SIMPLIFIED 01 ENERGY USE SUMMARY 03 04 Energy Use (kTDV/ftz-yr) Standard Design 07 Proposed Design Compliance Margin Percent Improvement Space Heating 3.09 4.78 -1.69 -54.7 Space Cooling 62.53 54.84 7.69 12.3 IAQ Ventilation 1.72 1.72 0 0 Water Heating 1.48 0.93 0.55 37.2 Self Utilization Credit n/a 0 0 n/a Compliance Energy Total 68.82 62.27 6.55 9.5 REQUIRED PV SYSTEMS - SIMPLIFIED 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size Azimuth Tilt Array Angle Inverter Eff. Annual (kWdc) Exception Module Type Array Type Power Electronics CFI (deg) Input (deg) Tilt: (x in 12) N Solar Access N 15 NA Standard Fixed(r) f Microinverters false 180 Degrees 0 0 98.3 100 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis REQUIRED SPECIAL FEATURES CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 3 of 23) Input File Name: Lot 42A Madison Club.ribdl9x The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. • Cool roof • Insulation above roof deck • Insulation below roof deck • Window overhangs and/or fins HERS FEATURE SUMMARY The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the buildng tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry Building -level Verifications: • Quality insulation installation (QII) • Building air leakage/reduced infiltration • Indoor air quality ventilation • Kitchen range hood Cooling System Verifications: • Minimum Airflow • Verified EER • Verified SEER • Verified Refrigerant Charge • Fan Efficacy Watts/CFM Heating System Verifications: • Verified HSPF • Verified heat pump rated heating capacity HVAC Distribution System Verifications: • Duct leakage testing • Low -leakage Air Handling Unit Domestic Hot Water System Verifications: • Pipe Insulation, All Lines BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name 2 Conditioned Floor Area (ft) Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems Lot 42A Madison Club 15847 1 6 12 0 1 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 4 of 23) Input File Name: Lot 42A Madison Club.ribdl9x ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft) Avg. Ceiling Height Water Heating System 1 Water Heating System 2 Zone 1 Conditioned HVAC System 11 663 10 DHW Sys 1 N/A Zone 2 Conditioned HVAC System 22 660 10 DHW Sys 1 N/A Zone 3 Conditioned HVAC System 33 622 10 DHW Sys 1 N/A Zone 4 Conditioned HVAC System 44 664 10 DHW Sys 1 N/A Zone 5 Conditioned HVAC System 55 1413 10 DHW Sys 1 N/A Zone 6 Conditioned HVAC System 66 1465 10 DHW Sys 1 N/A Zone 7 Conditioned HVAC System 77 2027 10 DHW Sys 1 N/A Zone 8 Conditioned HVAC System 88 2041 10 DHW Sys 1 N/A Zone 9 Conditioned HVAC System 99 2221 10 DHW Sys 1 N/A Zone 10 Conditioned HVAC System 1010 640 10 DHW Sys 1 N/A Zone 11 Conditioned HVAC System 1111 2566 10 DHW Sys 1 N/A Zone 12 Conditioned HVAC System 1212 865 10 DHW Sys 1 N/A OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) North Exterior Wall Zone 1 R-21 Wall 0 Front 312 135 90 East Exterior Wall Zone 1 R-21 Wall 90 Left 156 0 90 West Exterior Wall Zone 1 R-21 Wall 270 Right 346 0 90 North Exterior Wall 2 Zone 2 R-21 Wall 0 Front 300 134 90 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 5 of 23) Input File Name: Lot 42A Madison Club.ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) East Exterior Wall 2 Zone 2 R-21 Wall 90 Left 98 0 90 North Exterior Wall 3 Zone 3 R-21 Wall 0 Front 396 128 90 South Exterior Wall Zone 3 R-21 Wall 180 Back 96 0 90 East Exterior Wall 3 Zone 3 R-21 Wall 90 Left 192 0 90 North Exterior Wall 4 Zone 4 R-21 Wall 0 Front 9 0 90 South Exterior Wall 2 Zone 4 R-21 Wall 180 Back 240 14 90 West Exterior Wall 2 Zone 4 R-21 Wall 270 Right 396 124 90 East Exterior Wall 4 Zone 5 R-21 Wall 90 Left 312 216 90 South Exterior Wall 3 Zone 6 R-21 Wall 180 Back 264 192 90 West Exterior Wall 3 Zone 6 R-21 Wall 270 Right 672 576 90 South Exterior Wall 4 Zone 8 R-21 Wall 180 Back 444 90 90 East Exterior Wall 5 Zone 8 R-21 Wall 90 Left 684 0 90 Weat Exterior Wall Zone 8 R-21 Wall 270 Right 684 432 90 North Exterior Wall 5 Zone 9 R-21 Wall 0 Front 420 139.92 90 South Exterior Wall 5 Zone 9 R-21 Wall 180 Back 420 0 90 West Exterior Wall 4 Zone 9 R-21 Wall 270 Right 396 269 90 West Exterior Wall 5 Zone 10 R-21 Wall 270 Right 420 45 90 North Exterior Wall 6 Zone 11 R-21 Wall 0 Front 336 0 90 East Exterior Wall 6 Zone 11 R-21 Wall 90 Left 900 450 90 West Exterior Wall 6 Zone 11 R-21 Wall 270 Right 900 197 90 South Exterior Wall 6 Zone 12 R-21 Wall 180 Back 240 0 90 East Exterior Wall 7 Zone 12 R-21 Wall 90 Left 390 110 90 West Exterior Wall 7 Zone 12 R-21 Wall 270 Right 480 110 90 Roof Zone 1 R-38 HP Attic 38-21 n/a n/a 663 n/a n/a Roof 2 Zone 2 R-38 HP Attic 38-21 n/a n/a 660 n/a n/a Roof 3 Zone 3 R-38 HP Attic 38-21 n/a n/a 622 n/a n/a Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 6 of 23) Input File Name: Lot 42A Madison Club.ribdl9x OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft) Window and Door Area (ft2) Tilt (deg) Roof 4 Zone 4 R-38 HP Attic 38-21 n/a n/a 664 n/a n/a Roof 5 Zone 5 R-38 HP Attic 38-21 n/a n/a 1413 n/a n/a Roof 6 Zone 6 R-38 HP Attic 38-21 n/a n/a 1465 n/a n/a Roof 7 Zone 7 R-38 HP Attic 38-21 n/a n/a 2027 n/a n/a Roof 8 Zone 8 R-38 HP Attic 38-21 n/a n/a 1161 n/a n/a Roof 9 Zone 10 R-38 HP Attic 38-21 n/a n/a 640 n/a n/a Roof 10 Zone 11 R-38 HP Attic 38-21 n/a n/a 2566 n/a n/a Roof 11 Zone 12 R-38 HP Attic 38-21 n/a n/a 865 n/a n/a Raised Floor Zone 11 R-22 Floor Crawlspace n/a n/a 2566 n/a n/a Raised Floor 2 Zone 12 R-22 Floor Crawlspace n/a n/a 865 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12) Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Zone 1 Attic RoofZone 1 Unventilated 0 0.79 0.9 No Yes Attic Zone 2 Attic RoofZone 2 Unventilated 0 0.79 0.9 No Yes Attic Zone 3 Attic RoofZone 3 Unventilated 0 0.79 0.9 No Yes Attic Zone 4 Attic RoofZone 4 Unventilated 0 0.79 0.9 No Yes Attic Zone 5 Attic RoofZone 5 Unventilated 0 0.79 0.9 No Yes Attic Zone 6 Attic RoofZone 6 Unventilated 0 0.79 0.9 No Yes Attic Zone 7 Attic RoofZone 7 Unventilated 0 0.79 0.9 No Yes Attic Zone 8 Attic RoofZone 8 Unventilated 0 0.79 0.9 No Yes Attic Zone 10 Attic RoofZone 10 Unventilated 0 0.79 0.9 No Yes Attic Zone 11 Attic RoofZone 11 Unventilated 0 0.79 0.9 No Yes Attic Zone 12 Attic RoofZone 12 Unventilated 0 0.79 0.9 No Yes Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 7 of 23) Input File Name: Lot 42A Madison Club.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area (ft2) U -factor U -factor Source SHGC SHGC Sourc a Exterior Shading Window W-1 Window North Exterior Wall Front 0 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window W-2 Window North Exterior Wall Front 0 1 11 0.47 NFRC 0.19 NFRC Bug Screen Window D-37 Window North Exterior Wall Front 0 1 110 0.51 NFRC 0.23 NFRC Bug Screen Window W-3 Window North Exterior Wall 2 Front 0 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window D-23 Window North Exterior Wall 2 Front 0 1 120 0.51 NFRC 0.23 NFRC Bug Screen Window W-4 Window North Exterior Wall 3 Front 0 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window W-5 Window North Exterior Wall 3 Front 0 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window D-25 Window North Exterior Wall 3 Front 0 1 100 0.51 NFRC 0.23 NFRC Bug Screen Window W-8 Window South Exterior Wall 2 Back 180 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window W-7 Window West Exterior Wall 2 Right 270 1 14 0.47 NFRC 0.19 NFRC Bug Screen Window D-08 Window West Exterior Wall 2 Right 270 1 110 0.51 NFRC 0.23 NFRC Bug Screen Window D-28 Window East Exterior Wall 4 Left 90 18 12 1 216 0.51 NFRC 0.23 NFRC Bug Screen Window D-32 Window South Exterior Wall 3 Back 180 16 12 1 192 0.51 NFRC 0.23 NFRC Bug Screen Window W -D31 Window West Exterior Wall 3 Right 270 48 12 1 576 0.51 NFRC 0.23 NFRC Bug Screen Window W-6 Window South Exterior Wall 4 Back 180 6 6 1 36 0.47 NFRC 0.19 NFRC Bug Screen Window D-35 Window South Exterior Wall 4 Back 180 1 27 0.34 NFRC 0.23 NFRC Bug Screen Window D-33 Window Weat Exterior Wall Right 270 36 12 1 432 0.51 NFRC 0.23 NFRC Bug Screen Window D-04 Window North Exterior Wall 5 Front 0 60 12 0 79.92 0.34 NFRC 0.23 NFRC Bug Screen Window W-11 Window North Exterior Wall 5 Front 0 20 3 1 60 0.47 NFRC 0.19 NFRC Bug Screen Window D-12 Window West Exterior Wall 4 Right 270 1 180 0.51 NFRC 0.23 NFRC Bug Screen Window W-09 Window West Exterior Wall 4 Right 270 1 65 0.47 NFRC 0.19 NFRC Bug Screen Window D-14 Window West Exterior Wall 5 Right 270 4 9 1 45 0.34 NFRC 0.23 NFRC Bug Screen Window D-108 Window East Exterior Wall 6 Left 90 1 150 0.51 NFRC 0.23 NFRC Bug Screen Window D-112 Window East Exterior Wall 6 Left 90 1 160 0.51 NFRC 0.23 NFRC Bug Screen Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 8 of 23) Input File Name: Lot 42A Madison Club.ribdl9x FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft) Mult. Area z (ft) U -factor U -factor Source SHGC SHGC Sourc a Exterior Shading Window D-113 Window East Exterior Wall 6 Left 90 0.1 10 1 140 0.51 NFRC 0.23 NFRC Bug Screen Window W-101 Window West Exterior Wall 6 Right 270 0.1 6 1 83 0.47 NFRC 0.19 NFRC Bug Screen Window W-102 Window West Exterior Wall 6 Right 270 0.1 10 1 48 0.47 NFRC 0.19 NFRC Bug Screen Window W-103 Window West Exterior Wall 6 Right 270 0.1 4 1 66 0.47 NFRC 0.19 NFRC Bug Screen Window D-105 Window East Exterior Wall 7 Left 90 0.1 6 1 110 0.51 NFRC 0.23 NFRC Bug Screen Window D-106 Window West Exterior Wall 7 Right 270 1 110 0.51 NFRC 1 0.23 NFRC Bug Screen OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2) U -factor Door D-201 South Exterior Wall 4 27 0.5 Door D-03 West Exterior Wall 4 24 0.5 OVERHANGS AND FINS 01 02 03 04 05 06 07 O8 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-28 20 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-32 3 0.1 6 6 0 0 0 0 0 0 0 0 0 Window W -D31 20 0.1 10 10 0 0 0 0 0 0 0 0 0 Window W-6 4 0.1 4 4 0 0 0 0 0 0 0 0 0 Window D-33 3 0.1 6 6 0 0 0 0 0 0 0 0 0 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 9 of 23) Input File Name: Lot 42A Madison Club.ribdl9x OVERHANGS AND FINS 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Window Overhang Left Fin Right Fin Depth Dist Up Left Extent Right Extent Flap Ht. Depth Top Up Dist L Bot Up Depth Top Up Dist R Bot Up Window D-04 12 0.1 10 10 0 0 0 0 0 0 0 0 0 Window W-11 12 0.1 10 10 0 0 0 0 0 0 0 0 0 Window D-14 12 0.1 10 10 0 0 0 0 0 0 0 0 0 SLAB FLOORS 01 02 03 04 05 06 07 Name Zone Area (ft2) Perimeter (ft) Edge Insul. R -value and Depth Carpeted Fraction Heated Slab -on -Grade Zone 1 663 30 None 100% No Slab -on -Grade 2 Zone 2 660 0.1 None 100% No Slab -on -Grade 3 Zone 3 622 0.1 None 100% No Slab -on -Grade 4 Zone 4 664 0.1 None 100% No Slab -on -Grade 5 Zone 5 1413 30 None 100% No Slab -on -Grade 6 Zone 6 1465 70 None 100% No Slab -on -Grade 7 Zone 7 2027 70 None 100% No Slab -on -Grade 8 Zone 8 2041 140 None 100% No Slab -on -Grade 9 Zone 9 2221 90 None 100% No Slab -on -Grade 10 Zone 10 640 10 None 80% No Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 10 of 23) Input File Name: Lot 42A Madison Club.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U -factor Assembly Layers R -value R -value Inside Finish: Gypsum Board R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.069 Cavity / Frame: R-21 / 2x6 Exterior Finish: 3 Coat Stucco Inside Finish: Gypsum Board R-21 Walll Interior Walls Wood Framed Wall 2x6 @ 16 in. 0. C. R-21 None / None 0.064 Cavity / Frame: R-21 / 2x6 Other Side Finish: Gypsum Board Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 1 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 2 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 3 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 4 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 11 of 23) Input File Name: Lot 42A Madison Club.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Interior / Exterior Total Cavity Construction Name Surface Type Construction Type Framing R -value Continuous U -factor Assembly Layers R -value Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 5 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 6 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 7 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 8 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 10 Attic Roofs Wood Framed 2x4 @ 24 in. O. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 12 of 23) Input File Name: Lot 42A Madison Club.ribdl9x OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Required Not Required Required 5282.3 Interior / Exterior Construction Name Surface Type Construction Type Framing Total Cavity Continuous U -factor Assembly Layers R -value R -value Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 11 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Roofing: Light Roof (Asphalt Shingle) Above Deck Insulation: R-6 Sheathing Attic RoofZone 12 Attic Roofs Wood Framed 2x4 @ 24 in. 0. C. R-38 None / R-6 0.027 Roof Deck: Wood Ceiling Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-25.0 insul. Floor Surface: Carpeted R-22 Floor Crawlspace Floors Over Wood Framed Floor 2x8 @ 16 in. 0. C. R-19 None / None 0.047 Floor Deck: Wood Crawlspace Siding/sheathing/decking Cavity / Frame: R-19 / 2x8 R-38 HP Attic 38-21 Ceilings (below Wood Framed 2x12 @ 24 in. O. C. R-21 None /None 0.035 Cavity / Frame: R-21.0 / 2x12 attic) Ceiling Inside Finish: Gypsum Board BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50 Required Not Required Required 5282.3 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 13 of 23) Input File Name: Lot 42A Madison Club.ribdl9x WATER HEATING SYSTEMS 01 02 03 04 05 06 07 Name System Type Distribution Type Water Heater Name (#) Solar Heating System Compact Distribution HERS Verification DHW Sys 1 Domestic Hot Water (DHW) HERS Verified Pipe Insulation credit DHW Heater 1 (2) n/a None DHW Sys 1-hers-dhw WATER HEATERS 01 02 03 04 05 06 07 08 09 10 11 12 Type Compact Distribution Heating Central DHW Distribution Shower Drain Water Heat Recovery Tank Energy Not Required Tank Standby Loss Not Required Not Required Not Required Name Element Tank Type # Vol. Factor or Input Rating Insulation or Recovery 1st Hr. Rating NEEA Heat Pump Tank Location or Name Type Name Units (gal) Efficiency or Pilot R -value Eff. or Flow Rate Brand or Model Ambient Condition Air (Int/Ext) Heat pump heating cooling HVAC Fan 1 DHW Heater 1 Gas Consumer Storage 2 45 0.97-UEF 75 = k <<= 75 0 78 80 gal n/a n/a WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 08 Name Pipe Insulation Parallel Piping Compact Distribution Type Compact Distribution Recirculation Control Central DHW Distribution Shower Drain Water Heat Recovery DHW Sys 1 - 1/2 Required Not Required Not Required None Not Required Not Required Not Required SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count Heat Pump Heat Pump Air HVAC System 11 Heat pump heating cooling HVAC Fan 1 Distribution Setback New NA 1 1 System 1 System 1 System 1 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 14 of 23) Input File Name: Lot 42A Madison Club.ribdl9x SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Distribution Required Verified Heating Cooling Name System Type Fan Name Thermostat Status Existing Equipment Equipment Name Name Name Type Condition Count Count Air HVAC System 22 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 2 Distribution Setback New NA 1 1 System 2 System 2 System 2 Air HVAC System 33 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 3 Distribution Setback New NA 1 1 System 3 System 3 System 3 Heat Pump Heat Pump Air HVAC System 44 Heat pump heating cooling HVAC Fan 4 Distribution Setback New NA 1 1 System 4 System 4 System 4 Heat Pump Heat Pump Air HVAC System 55 Heat pump heating cooling HVAC Fan 5 Distribution Setback New NA 1 1 System 5 System 5 System 5 Air HVAC System 66 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 6 Distribution Setback New NA 1 1 System 6 System 6 System 6 Air HVAC System 77 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 7 Distribution Setback New NA 1 1 System 7 System 7 System 7 Air HVAC System 88 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 8 Distribution Setback New NA 2 2 System 8 System 8 System 8 Heat Pump Heat Pump Air HVAC System 99 Heat pump heating cooling HVAC Fan 9 Distribution Setback New NA 1 1 System 9 System 9 System 9 Heat Pump Heat Pump Air HVAC System 1010 Heat pump heating cooling HVAC Fan 10 Distribution Setback New NA 1 1 System 10 System 10 System 10 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 15 of 23) Input File Name: Lot 42A Madison Club.ribdl9x SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 Heating Unit Cooling Unit Cooling Distribution Required Verified Heating Cooling Name System Type HERS Verification Fan Name Thermostat Status Existing Equipment Equipment HSPF/COP Cap 47 Name Name EER Name Type Condition Count Count 10 27600 26220 18.6 12.5 Air Multi- Heat Pump System HVAC System 1111 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 11 Distribution Setback New NA 4 4 10 27600 System 11 System 11 12.5 System 11 Multi- Heat Pump System Air speed 2-hers-htpump Heat Pump System 3 Central split HP 1 HVAC System 1212 Heat pump heating cooling Heat Pump Heat Pump HVAC Fan 12 Distribution Setback New NA 1 1 System 12 System 12 System 12 speed 3-hers-htpump Heat Pump System 4 Central split HP 1 HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 1 Central split HP 1 10 27600 26220 18.6 12.5 Zonally Multi- Heat Pump System Controlled speed 1-hers-htpump Heat Pump System 2 Central split HP 1 10 27600 26220 18.6 12.5 Zonally Multi- Heat Pump System Controlled speed 2-hers-htpump Heat Pump System 3 Central split HP 1 10 27600 26220 18.6 12.5 Zonally Multi- Heat Pump System Controlled speed 3-hers-htpump Heat Pump System 4 Central split HP 1 12 24000 21800 22 14 Zonally Multi- Heat Pump System Controlled speed 4-hers-htpump Heat Pump System 5 Central split HP 1 11 59000 49500 21 13 Zonally Multi- Heat Pump System Controlled speed 5-hers-htpump Heat Pump System 6 Central split HP 1 12 56000 52500 18 12.5 Zonally Multi- Heat Pump System Controlled speed 6-hers-htpump Heat Pump System 7 Central split HP 1 11 59000 49500 21 13 Zonally Multi- Heat Pump System Controlled speed 7-hers-htpump Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 16 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 Airflow Target Verified EER Verified SEER Heating Cooling Zonally Compressor Name System Type Number of Units Controlled Type HERS Verification Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes HSPF/COP Cap 47 Cap 17 SEER EER Heat Pump System 8 Central split HP 2 11 45500 43225 17 11 Zonally Multi- Heat Pump System Yes Yes 2-hers-htpump Controlled speed 8-hers-htpump Heat Pump System 9 Central split HP 1 11 59000 49500 21 13 Zonally Multi- Heat Pump System Heat Pump System Controlled speed 9-hers-htpump Heat Pump System Central split HP 1 10 27600 26220 18.6 12.5 Not Zonal Single Heat Pump System 10 Heat Pump System Required 350 Required Required Yes Speed 10-hers-htpump Heat Pump System Central split HP 4 12 24000 21800 22 14 Zonally Multi- Heat Pump System 11 350 Required Required Yes Yes Yes Yes Controlled speed 11-hers-htpump Heat Pump System Central split HP 1 12 24000 21800 22 14 Zonally Multi- Heat Pump System 12 Controlled speed 12-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 1-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 2-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 3-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 4-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 5-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 6-hers-htpump Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 17 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant Verified HSPF Verified Heating Verified Heating Charge Cap 47 Cap 17 Heat Pump System Required 350 Required Required Yes Yes Yes Yes 7-hers-htpump Return Duct Leakage Heat Pump System Required 350 Not Required Required Yes Yes Yes Yes 8-hers-htpump Heat Pump System Required 350 Required Required Yes Yes Yes Yes 9-hers-htpump NO Air Distribution Heat Pump System Required 350 Required Required No Yes Yes Yes 10-hers-htpump Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass Heat Pump System Required 350 Required Required Yes Yes Yes Yes 11-hers-htpump Tested System Heat Pump System Required 350 Required Required Yes Yes Yes Yes 12-hers-htpump HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R -value Duct Location Surface Area Bypass HERS Name Type Design Type Supply Return Supply Return Supply Return Duct Leakage Verification Air NO Air Distribution Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 1 Tested System Duct 1 -hers -dist Air NO Air Distribution Sealed and Distribution Unconditioned attic Non Verified R-8 R-8 Attic Attic n/a n/a Bypass System 2 Tested System Duct 2 -hers -dist Air Air Distribution NO Sealed and Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 3 Tested System Duct 3 -hers -dist Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 18 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R -value Duct Location Surface Area Bypass HERS Name Type Design Type Supply Return Supply Return Supply Return Duct Leakage Verification Air NO Air Distribution Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 4 System Duct 4 -hers -dist Air NO Air Distribution Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 5 System Duct 5 -hers -dist Air NO Air Distribution Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 6 System Duct 6 -hers -dist Air NO Air Distribution Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 7 System Duct 7 -hers -dist Air Air Distribution NO Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 8 System Duct 8 -hers -dist Air NO Air Distribution Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 9 System Duct 9 -hers -dist Air NO Air Distribution Sealed and Distribution Unconditioned attic Non Verified R-8 R-8 Attic Attic n/a n/a Bypass System 10 Tested System Duct 10 -hers -dist Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 19 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Duct Ins. R -value Duct Location Surface Area Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Bypass HERS Name Type Design Type Supply Return Supply Return Supply Return Duct Leakage Space Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Verification No System 1 -hers -dist Air Distribution Air 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 2 -hers -dist NO Air Distribution Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Distribution No Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass Air Distribution Yes System 11 Not Required Not Required Not Required Credit not taken Required No System 4 -hers -dist System Air Distribution Yes 3.0 Not Required Not Required Duct Credit not taken Required No System 5 -hers -dist 11 -hers -dist Air NO Air Distribution Distribution Unconditioned attic Non -Verified R-8 R-8 Attic Attic n/a n/a Bypass System 12 System Duct 12 -hers -dist HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target (%) Location Design g Ducts Handler Conditioned Space Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 1 -hers -dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 2 -hers -dist Air Distribution Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No System 3 -hers -dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 4 -hers -dist Air Distribution Yes 3.0 Not Required Not Required Not Required Credit not taken Required No System 5 -hers -dist Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 20 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 HVAC Fan 0.23 HVAC Fan 1 -hers -fan HVAC Fan 2 HVAC Fan 0.23 HVAC Fan 2 -hers -fan Low Leakage Name Duct Leakage Duct Leakage Verified Duct Verified Duct Buried Ducts Deeply Buried Low -leakage Air Ducts Entirely in Verification Target g ( ) Location Design Ducts Handler Conditioned Space Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 6 -hers -dist Air Distribution Yes 3.0 Not Required Not Required Not Required Credit not taken Required No System 7 -hers -dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 8 -hers -dist Air Distribution Yes 2.0 Not Required Not Required Not Required Credit not taken Required No System 9 -hers -dist Air Distribution System Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No 10 -hers -dist Air Distribution System Yes 2.0 Not Required Not Required Not Required Credit not taken Required No 11 -hers -dist Air Distribution System Yes 2.0 Not Required Not Required Not Required Credit not taken Required No 12 -hers -dist HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 1 HVAC Fan 0.23 HVAC Fan 1 -hers -fan HVAC Fan 2 HVAC Fan 0.23 HVAC Fan 2 -hers -fan Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 21 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM) Name HVAC Fan 3 HVAC Fan 0.23 HVAC Fan 3 -hers -fan HVAC Fan 4 HVAC Fan 0.23 HVAC Fan 4 -hers -fan HVAC Fan 5 HVAC Fan 0.33 HVAC Fan 5 -hers -fan HVAC Fan 6 HVAC Fan 0.33 HVAC Fan 6 -hers -fan HVAC Fan 7 HVAC Fan 0.32 HVAC Fan 7 -hers -fan HVAC Fan 8 HVAC Fan 0.28 HVAC Fan 8 -hers -fan HVAC Fan 9 HVAC Fan 0.58 HVAC Fan 9 -hers -fan HVAC Fan 10 HVAC Fan 0.58 HVAC Fan 10 -hers -fan HVAC Fan 11 HVAC Fan 0.32 HVAC Fan 11 -hers -fan HVAC Fan 12 HVAC Fan 0.23 HVAC Fan 12 -hers -fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1 -hers -fan Required 0.23 HVAC Fan 2 -hers -fan Required 0.23 HVAC Fan 3 -hers -fan Required 0.23 HVAC Fan 4 -hers -fan Required 0.23 HVAC Fan 5 -hers -fan Required 0.33 HVAC Fan 6 -hers -fan Required 0.33 HVAC Fan 7 -hers -fan Required 0.32 HVAC Fan 8 -hers -fan Required 0.28 HVAC Fan 9 -hers -fan Required 0.58 Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 22 of 23) Input File Name: Lot 42A Madison Club.ribdl9x HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 10 -hers -fan Required 0.58 HVAC Fan 11 -hers -fan Required 0.32 HVAC Fan 12 -hers -fan Required 0.23 IAQ (INDOOR AIR QUALITY) FANS 01 02 03 04 05 06 Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type IAQ Recovery Effectiveness (%) IAQ Recovery Effectiveness - SREIAQ Recovery Effectiveness -SRE SFam IAQVentRpt 464 0.25 Default 0 n/a Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101 CERTIFICATE OF COMPLIANCE Project Name: Lot 42A Madison Club Calculation Description: Title 24 Analysis CF1R-PRF-01E Calculation Date/Time: 2022-08-31T07:59:44-07:00 (Page 23 of 23) Input File Name: Lot 42A Madison Club.ribdl9x DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Butch White 13 [rock W1We., Company: Signature Date: Breeze Air Conditioning LLC 08/31/2022 Address: CEA/ HERS Certification Identification (If applicable): 75-145 Street Charles Place City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name: Responsible Designer Signature: Butch White 18 atck Whitel Company: Date Signed: Breeze Air Conditioning LLC 08/31/2022 Address: License: 75-145 Street Charles Place 1045015 City/State/Zip: Phone: Palm Desert, CA 92211 (760) 346-0855 Digitally signed by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 422-P010137120A-000-000-0000000-0000 Registration Date/Time: 08/31/2022 08:00 HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.108 Report Generated: 2022-08-31 08:04:01 Schema Version: rev 20200101