BCOM2019-0069Description: CART MART / 15,744 SF GOLF CART SALES SHOWROOM T.I.
Type: BUILDING COMMERCIAL Subtype: REMODEL Status: FINALED Applied: 11/24/2019 EPRS
(WEB)
Parcel No: 643220025 Site Address: 78525 HIGHWAY 111 STE 200 LA QUINTA,CA 92253 Approved: 2/4/2020 JFU
Subdivision: PM 29791 Block: Lot: 1 Issued: 2/6/2020 EPRS
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: 5/22/2020 JFU
Valuation: $125,000.00 Occupancy Type: Construction Type: Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: CART MART/ 15,744 SF GOLF CART SALES SHOWROOM TENANT IMPROVEMENT [VA/M-OCC/238-OL/SPRINKLED] THIS PERMIT
DOES NOT INCLUDE BUILDING SIGNAGE, ALTERATION TO EXISTING FIRE RESISTANCE RATED CONSTRUCTION, NOR ALTERATION TO
LOAD BEARING OR LATERAL RESISTING CONSTRUCTION. NO TUMF ASSESSMENT PER 2018 HANDBOOK. NEW SIGNAGE, NEW CURB
RAMP, RESTROOM UPGRADES AND DRINKING FOUNTAIN AS PATH OF TRAVEL UPGRADES. 2016 CALIFORNIA BUILDING CODES.
Unit 200.
*Existing LG's Restaurant is Unit 100
**Existing Vacant Suite on SE Corner is Unit 300
60 -DAY TEMPORARY CERTIFICATE OF OCCUPANCY ISSUED 4/7/2020 (EXPIRES 6/6/2020). SEE FINAL INSPECTION NOTES DATED
4/7/2020 FOR LIST OF ITEMS REQUIRED TO BE CORRECTED IN ORDER TO GAIN FINAL APPROVAL AND ISSUANCE OF THE PERMANENT
CERTIFICATE OF OCCUPANCY.
REVISION 1 - ELECTRICAL CHANGES. ADDED CIRCUITRY AND REVISED PANEL SCHEDULES.
2
72
106
i Applied to Approved
Approved to Issued
Issued to Finaled
Printed: Wednesday, July 05, 2023 10:07:28 AM 1 of 15
RWsYsrEMS
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
60 -DAY TEMPORARY CERTIFICATE OF OCCUPANCY ISSUED
4/7/2020 (EXPIRES 6/6/2020). SEE FINAL INSPECTION NOTES
CERTIFICATE OF
JAKE FUSON
4/7/2020
4/7/2020
DATED 4/7/2020 FOR LIST OF ITEMS REQUIRED TO BE
OCCUPANCY
CORRECTED IN ORDER TO GAIN FINAL APPROVAL AND
ISSUANCE OF THE PERMANENT CERTIFICATE OF OCCUPANCY.
E-MAIL
JAKE FUSON
1/9/2020
1/9/2020
NOTIFIED RUBEN CORONADO OF IST PLAN REVEIW
CORRECTIONS, SENT CORRECTION LIST VIA EMAIL.
Printed: Wednesday, July 05, 2023 10:07:28 AM 1 of 15
RWsYsrEMS
FINANCIAL INFORMATION
CLTD
NOTIFIED RUBEN CORONADO OF 2ND REVIEW CORRECTIONS.
E-MAIL
JAKE FUSON
1/31/2020
1/31/2020
DESCRIPTION
NO FORMAL CORRECTION LIST CREATED DUE TO MINOR
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
SCOPE OF CORRECTIONS.
BY
TEMPORARY
NOTIFIED APPLICANT, CONTRACTOR AND BUSINESS OWNER
E-MAIL
JAKE FUSON
2/4/2020
2/4/2020
THAT PLANS WERE APPROVED AND PERMIT IS READY TO
101-0000-42600
0
$483.00
$483.00
4/10/20
WEB4855
CREDIT
Ruben Coronado
ISSUE ONLINE.
OCCUPANCY
CONDITIONS
CONDITION
DATE
Total Paid for ADMINISTRATIVE: $483.00 $483.00
DATE
DATE
CONTACT
STATUS
REMARKS
NOTES
TYPE
ADDED
REQUIRED
SATISFIED
PROPERTY OWNER NAME DOES NOT MATCH
COUNTY RECORDS. PLEASE PROVIDE COPY OF
GRANT DEED. ALSO, LETTER OF AUTHORIZATION
READY TO ISSUE
BUILDING
FROM PROPERTY OWNER IS REQUIRED FOR
CHECKLIST
BUCKET
11/27/2019
2/4/2020
COMPLETE
TENANT IMPROVEMENTS.
UPDATE: OWNER CORRECTED, OWNER
AUTHORIZATION NOT REQUIRED PER BUILDING
OFFICIAL'S DETERMINATION.
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
Ruben Coronado
73-700 Dinah Shore
Palm Desert
CA
92211
ruben@statewideinc.n
Drive
et
CONTRACTOR
STATEWIDE SERVICES INC DBA
73-700 DINAH SHORE
PALM DESERT
CA
92211
RUBEN@STATEWIDEIN
STATEWIDE CON
DR #405
1
1
1
1
1
1 C.NET
OWNER
JDD
FINANCIAL INFORMATION
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
TEMPORARY
CERTIFICATE OF
101-0000-42600
0
$483.00
$483.00
4/10/20
WEB4855
CREDIT
Ruben Coronado
EPRS
OCCUPANCY
Total Paid for ADMINISTRATIVE: $483.00 $483.00
Printed: Wednesday, July 05, 2023 10:07:28 AM 2 of 15
WsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 3 of 15
WsYsrEMS
CLTD
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID
BY
ART IN PUBLIC PLACES -
270-0000-43201
0
$125.00
$125.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
COMMERCIAL REMOD
Total Paid for ART IN PUBLIC PLACES - AIPP: $125.00 $125.00
HOURLY CHARGE - CITY
101-0000-42600
1
$161.00
$161.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
BUILDING STAFF
HOURLY CHARGE - CITY
101-0000-42600
0.33
$53.13
$53.13
5/20/20
WEB5227
CREDIT
Ruben Coronado
EPRS
BUILDING STAFF
HOURLY CHARGE -
INTERWEST
101-0000-42600
1
$125.00
$125.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
STRUCTURAL PLAN
REVIEW
Total Paid for BLDG CITY STAFF - PER HOUR: $339.13 $339.13
BSAS SB1473 FEE
1 101-0000-20306
1 0
$5.00
$5.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
Total Paid for BUILDING STANDARDS ADMINISTRATION $5.00 $5.00
BSA:
Credit Card Fee
101-0000-43505
0
$2.72
$2.72
11/24/19
WEB4344
CREDIT
Ruben Coronado
EPRS
Total Paid for Credit Card Fee: $2.72 $2.72
NON-RESIDENTIAL, EA
101-0000-42403
0
$281.75
$281.75
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
ADDITIONAL 2,000SF
NON-RESIDENTIAL, EA
101-0000-42600
0
$75.11
$75.11
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
ADDITIONAL 2,000SF PC
NON-RESIDENTIAL,
101-0000-42403
0
$120.75
$120.75
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
FIRST 2,OOOSF
NON-RESIDENTIAL,
101-0000-426000
$93.38
$93.38
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
FIRST 2,000SF PC
Total Paid for ELECTRICAL - NEW CONSTRUCTION 2019: $570.99 $570.99
101-0000-42600
($125.00)
($125.00)
12/9/19
OFFSET
OFFSET
KHET
FIRE COMMERCIAL TI
101-0000-42421
0
$125.00
$125.00
12/9/19
DEPOSIT
DEPOSIT
KHET
Printed: Wednesday, July 05, 2023 10:07:28 AM 3 of 15
WsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 4 of 15
WsYsrEMS
■ ■
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
FIRE COMMERCIAL TI
101-0000-42421
0
$36.00
$36.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
FIRE COMMERCIAL TI
101-0000-42420
0
$242.00
$242.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
PC
FIRE FAILED OR
ADDITIONAL RE-
101-0000-42421
0
$161.00
$161.00
4/7/20
WEB4833
CREDIT
Ruben Coronado
EPRS
INSPECTION
Total Paid for FIRE FEES: $439.00 $439.00
OTHER MECHANICAL
101-0000-42402
0
$161.00
$161.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
EQUIPMENT
OTHER MECHANICAL
101-0000-42600
0
$161.00
$161.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
EQUIPMENT PC
VENT FAN
101-0000-42402
0
$26.84
$26.84
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
VENT FAN PC
101-0000-42600
0
$10.74
$10.74
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
Total Paid for MECHANICAL 2019: $359.58 $359.58
PLAN CHECK DEPOSIT -
101-0000-426001
$125.00
$125.00
11/24/19
WEB4344
CREDIT
Ruben Coronado
EPRS
ADDITION/REMODEL
Total Paid for PLAN CHECK DEPOSIT - ADDITION/REMODEL: $125.00 $125.00
FIXTURE/TRAP
101-0000-42401
0
$40.26
$40.26
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
FIXTURE/TRAP PC
101-0000-42600
0
$40.26
$40.26
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
WATER HEATER/VENT
101-0000-42401
0
$13.42
$13.42
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
WATER HEATER/VENT
101-0000-42600
0
$8.05
$8.05
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
PC
WATER SYSTEM
101-0000-42401
0
$13.42
$13.42
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
INST/ALT/REP
WATER SYSTEM
101-0000-42600
0
$13.42
$13.42
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
INST/ALT/REP PC
Total Paid for PLUMBING 2019: $128.83 $128.83
Printed: Wednesday, July 05, 2023 10:07:28 AM 4 of 15
WsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 5 of 15
RWsYsrEMS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID
BY
RECORDS
MANAGEMENT FEE -
101-0000-42416
0
$21.00
$21.00
11/24/19
WEB4344
CREDIT
Ruben Coronado
EPRS
MAJOR
Total Paid for RECORDS MANAGEMENT FEE - MAJOR: $21.00 $21.00
REMODEL, EA
101-0000-42400
0
$772.80
$772.80
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
ADDITIONAL 500SF
REMODEL, EA
101-0000-42600
0
$618.24
$618.24
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
ADDITIONAL 500SF PC
REMODEL, FIRST 100SF
101-0000-42600
0
$149.73
$149.73
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
PC
Total Paid for REMODEL 2019: $1,540.77 $1,540.77
SMI -COMMERCIAL
101-0000-20308
0
$35.00
$35.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $35.00 $35.00
TECHNOLOGY
502-0000-436110
$5.00
$5.00
11/24/19
WEB4344
CREDIT
Ruben Coronado
EPRS
ENHANCEMENT FEE
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
ALTERATIONS/ADDITIO
101-0000-424000
$161.00
$161.00
2/6/20
WEB4556
CREDIT
Ruben Coronado
EPRS
NS - NON-RESIDENTIAL
Total Paid for ZONING CLEARANCE - PLANNING PLAN
$161.00 $161.00
CHECK:
TOTALS:
INSPECTIONS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED RESULT REMARKS NOTES
DATE DATE
BREAK ROOM SINK AND FUTURE COFFEE
STATION ONLY. VERIFY CLEANOUTS AT BOTH
UNDERGROUND PLBG JFU 2/12/2020 2/12/2020
PARTIALLY
OF THESE LOCATIONS AT ROUGH PLUMBING
APPROVED
INSPECTION. DOES NOT INCLUDE MOP SINK
PIPING, TO BE INSPECTED AT A LATER TIME.
Printed: Wednesday, July 05, 2023 10:07:28 AM 5 of 15
RWsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 6 of 15
WsYsrEMS
2/13/2020 1:17 PM Ruben Coronado
Contact Name: Ruben Coronado
Site Address: 78525 HIGHWAY 111
Phone:7608921494
e -Mail: mike@greentowneinc.com
DISAPPROVE
eTRAKiT Inspection
FRAMING
JFU
2/14/2020
2/14/2020
D
Request
INSPECTION ENDED BY INSPECTOR DUE TO
INCOMPLETENESS OF CONSTRUCTION.
COMPLETE ALL REMAINING FRAMING AND
ROUGH ELECTRICAL AND RECALL
INSPECTION. CONTRACTOR NOTIFIED OF
WATER CLOSET CLEARANCES AND THE NEED
FOR A 3'0" DOOR AT THE ELECTRICAL ROOM.
2/19/2020 1:50 PM Ruben Coronado
Contact Name: Ruben Coronado
Site Address: 78525 HIGHWAY 111
Phone:7608921494
e -Mail: ruben@statewideinc.net
VERIFY EXCEPTIONS BELOW AT NEXT
INSPECTION
REMOVE ACCESSIBLE ABANDONED
ELECTRICAL ITEMS
FRAME OUT OR INSTALL ACCESS PANEL FOR
J -BOX AT NORTHWEST INTERIOR WALL
PROVIDE PERMANENT CAPS AT
ABANDONED PLASTIC PIPING
THROUGHOUT. SEE DRAIN PIPE ON
NORTHWEST CORNER WALL, NEW OFFICE
AREA PASS THROUGH AREA, AND
SOUTHEAST ELECTRICAL ROOM.
Printed: Wednesday, July 05, 2023 10:07:28 AM 6 of 15
WsYsrEMS
FRAMING
DCL
2/21/2020 1
2/21/2020
APPROVED
W/EXCEPTIO
N
eTRAKiT Inspection
Request
SECURE SILL TRACK TO WALL STUDS ON
BOTH SIDES AT FURRED WALLS PER PLAN
PROVIDE BOX BEAM HEADER AND SUPPORT
STUDS AT OFFICE PASS THROUGH
SECURE PLUMBING THROUGH STUDS AT
BREAK ROOM SINK
PROVIDE DRAIN PIPING ON TEST FOR
INSPECTION
PROVIDE LIGHT SWITCH ROUGH IN AT
ICES. WIRELESS LUTRON VIBE SYSTEM TO
BE USED PER ELECTRICIAN.
UNDERGROUND INSPECTION OF MOP SINK
REQUIRED. NO UNDERGROUND INSPECTION
ON RECORD. WORK COVERED AT JANITOR'S
CLOSET PRIOR TO INSPECTION.
CLEAN OUTS REQUIRED AT BREAK ROOM
AND FUTURE COFFEE MACHINE AREA.
PARTIAL DRYWALL NAIL INSPECTION
APPROVAL FOR SINGLE SIDE SHEETED WALLS
ACCESS REQUIRED TO ENCLOSED ATTIC
SPACE ABOVE RESTROOMS AND JANITOR'S
CLOSET. MINIMUM 20X30 ACCESS OPENING
REQUIRED PER 2016 CBC 1209.2.
PROVIDE BOX HEADER AT ELECTRICAL
ROOM, SEE 2, 5-103
VERIFY UNDERGROUND INSPECTION FOR
MOP SINK AND COFFEE MACHINE FUTURE
WITH PREVIOUS INSPECTOR.
Printed: Wednesday, July 05, 2023 10:07:28 AM 7 of 15
RWsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 8 of 15
WsYsrEMS
2/19/2020 1:51 PM Ruben Coronado
Contact Name: Ruben Coronado
APPROVED
eTRAKiT Inspection
Site Address: 78525 HIGHWAY 111
ROUGH ELEC
DCL
2/21/2020
2/21/2020
W/EXCEPTIO
Request
Phone: 7608921494
N
e -Mail: ruben@statewideinc.net
- SEE 2/21/2020 FRAMING INSPECTION.
DRYWALL NAIL
DCL
2/21/2020
2/21/2020
PARTIALLY
- SINGLE SIDES AT PARTITION WALLS
APPROVED
THROUGHOUT.
2/25/2020 7:43 AM Ruben Coronado
restroom wall plumbing
Contact Name: Mike
Site Address: 78525 HIGHWAY 111
Phone:7608805195
e -Mail: mike@greentowneinc.com
ROUGH PLBG
DCL
2/26/2020
2/26/2020
APPROVED
eTRAKiT Inspection
UNDERGROUND INSPECTION OF MOP SINK
Request
REQUIRED. WORK COVERED AT JANITOR'S
CLOSET. PICTURES FORTHCOMING FROM
PROJECT MANAGER. REQUESTED
CLARIFICATION ON USE FOR PLUMBING
FUTURE AT SOUTHWEST CORNER OF
BUILDING PRIOR TO DRYWALLING
SOUTHWEST WALL, AT PLUMBING TIE INS.
FRAMING
DCL
2/26/2020
2/26/2020
APPROVED
- SEE ROUGH PLUMBING EXCEPTION.
ROUGH ELEC
DCL
2/26/2020
2/26/2020
APPROVED
2/25/2020 7:41 AM Ruben Coronado
correction list by Inspector completed
Contact Name: mike Green
DRYWALL NAIL
DCL
2/27/2020
2/27/2020
APPROVED
eTRAKiT Inspection
Site Address: 78525 HIGHWAY 111
Request
Phone:7608805195
e -Mail: mike@greentowneinc.com
Printed: Wednesday, July 05, 2023 10:07:28 AM 8 of 15
WsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 9 of 15
WsYsrEMS
OVERHEAD ROUGH
KHET
3/10/2020
3/10/2020
APPROVED
PIPING
PENDING OVERHEAD APPROVAL FROM
FIRE.- PROVIDE RIVETS AND CLIPS AT
ADJACENT WALLS AS REQUIRED. SOME
T-BAR/OVERHEAD
DCL
3/10/2020
3/10/2020
DISAPPROVE
AREAS INCOMPLETE.- COMPLETE
D
OVERHEAD ELECTRICAL TO LIGHTING. -
PROVIDE SUPPORT WIRES TO REGISTERS
AND LIGHTING AS REQUIRED
3/11/2020 3:35 PM Ruben Coronado
Contact Name: mike green
T-BAR/OVERHEAD
DCL
3/12/2020
3/12/2020
APPROVED
eTRAKiT Inspection
Site Address: 78525 HIGHWAY 111
Request
Phone:7608805195
e -Mail: mike@greentowneinc.com
WORK INCOMPLETE. DESIGNER AND
FINAL"
JFU
3/16/2020
3/16/2020
NOT READY
CONTRACTOR NOTIFIED OF NOW
COMPLIANCE OF NEW FRONT CURB RAMP.
WORK HAD ALREADY BEEN INSPECTED AND
T-BAR/OVERHEAD
AOR
3/20/2020
3/20/2020
PARTIALLY
APPROVED, THIS INSPECTION WAS FOR
APPROVED
CLEAN UP OF REMOVED ELECTRICAL
INSTALLATIONS.
T/I FINAL
KHET
3/25/2020
3/25/2020
DISAPPROVE
See corrections in Attachments
FINAL FOR OCCUPANCY
KHET
3/25/2020
3/25/2020
DISAPPROVE
See corrections in attachments
T/I FINAL
KHET
4/6/2020
4/6/2020
APPROVED
Remote Video Inspection
FINAL FOR OCCUPANCY
KHET
4/6/2020
4/6/2020
APPROVED
Remote Video Inspection
Printed: Wednesday, July 05, 2023 10:07:28 AM 9 of 15
WsYsrEMS
FINAL"
JFU
4/7/2020
4/7/2020
DISAPPROVE
D
-PROVIDE CLOSEOUT ENERGY FORMS (NRCA
& NRCI FORMS)
-REVISE PANEL SCHEDULES FOR ACCURACY
-OBTAIN FINAL APPROVAL FOR THE SIGN
PERMIT ASSOCIATED WITH THIS BUSINESS
-OBTAIN FINAL APPROVAL FROM THE CITY'S
PLANNING DIVISION
-CORRECT THE CURB RAMP
-PROVIDE KNEE CLEARANCE IN
ACCORDANCE WITH CBC 1113-306.3 AT THE
BREAK ROOM SINK
-REMOVE THE LOCK FROM THE EXIT DOOR
AT THE REAR OF THE BUILDING
-PROVIDE PEDESTRIAN PROTECTION AT
DRINKING FOUNTAIN
-PROVIDE PLAN REVISION FOR THE OMITTED
OFFICE
-CORRECT THE HARDWARE AT THE
SOUTHEAST EXIT DOOR PER PLAN, THIS
DOOR SHOULD NOT BE ABLE TO BE LOCKED
FROM THE EGRESS SIDE
UPDATE: CERTIFICATES OF INSTALLATION
AND ACCEPTANCE RECEIVED VIA EMAIL.
CURB RAMP REMOVED AND REPLACED
WITH ACCESSIBLE, LEVEL CIRCULATION PATH
ABOVE, WITH CITY STANDARD "C" CURB
FINAL" JFU 5/22/2020 5/22/2020 APPROVED TRANSITION TO LOWER LEVEL VEHICULAR
WAY PER CONVERSATIONS BETWEEN
BUILDING DEPARTMENT STAFF AND
CONTRACTOR.
Printed: Wednesday, July 05, 2023 10:07:28 AM
10 of 15
CRWSY5TEM5
1ST PERMIT TECH —
ETRAKIT (1 DAY)
JACK LIMA
11/25/2019
12/5/2019
12/2/2019
COMPLETE
SENT EMAIL TO INTERWEST CONTACT DIEGO
GOMEZ INTERWEST INFORMING HIM OF THE
COMPLETE REVIEW.
IST PLANNING —
SIJIFREDO
11/25/2019
12/5/2019
12/2/2019
READY FOR APPROVAL
ETRAKIT (1 WK)
FERNANDEZ
FIRE GENERAL CONDITIONS
Fire Department approval is based upon the 2016
CBC requirements for B and M occupancies. It is
prohibited to use, process or store any materials
in the occupancy that would classify it as a Group
H occupancy, without further review and
approval.
DEFERRED SUBMITTALS REQUIRED
1) FIRE SPRINKLER—Tenant Improvement plans
must be submitted and reference the installing
contractor performing the work. Permit fees will
be required.
PRIOR TO FINAL INSPECTION
1) Install Knox Key Lock box, mounted per
recommended standard of the Knox Company.
Special forms are available from this office for the
ordering of the Key Switch. This form must be
authorized and signed by this office for the
correctly coded system to be purchased.
2) Provide keys to the tenant space for inclusion
in the main building Knox Box. Key(s) shall have
durable and legible tags affixed for identification
of the correlating tenant space.
3) Approved building address shall be placed in
such a position as to be plainly visible and legible
from the street and rear access if applicable.
Building address numbers shall be a minimum of
12". Minimum 6" tall suite addressing shall be
1ST FIRE - ETRAKIT
KOHL
11/25/2019
12/5/2019
12/9/2019
READY FOR APPROVAL
SEE NOTES
provided to both the front and rear entrances. All
(1 WK)
HETRICK
addressing must be legible and of a contrasting
color with the to be visible from the street at all
hours.
Printed: Wednesday, July 05, 2023 10:07:28 AM 11 of 15
RWsYsrEMS
1ST BLDG NS (3 WK) I JAKE FUSON 11/25/2019 12/18/2019 1 1/9/2020 1 REVISIONS REQUIRED
4) Install portable fire extinguishers per Title 19,
but not less than 2A10BC in rating. All new and
existing portable fire extinguishers shall have
current annual servicing performed and tagged.
5) Applicable room door(s) shall be posted
"ELECTRICAL", "FACP", "FIRE RISER" and "ROOF
ACCESS" on the outside of the door so it is visible
and in a contrasting color.
6) A durable sign stating: "THIS DOOR TO REMAIN
UNLOCKED WHEN THIS SPACE IS OCCUPIED" shall
be placed on or adjacent to the front exit doors.
The sign shall be in letters not less than one inch
high on a contrasting background (A <300, B, F, M
and S).
7) Illuminated Exit Signage and Egress
Illumination placement and functional test will be
witnessed by OFM Fire Inspector at time of final
inspection.
The Fire Department approved plans and
conditions letter must be at the job site.
Applicant/installer shall be responsible to contact
the Fire Department to schedule inspections.
Requests for inspections are to be made at least
72 hours in advance and may be arranged by
calling (760)777-7131.
SENT EMAIL TO INTERWEST CONTACT DIEGO
GOMEZ INTERWEST INFORMING HIM OF THE
COMPLETE REVIEW.
SEE IST REVIEW COMPLETE CORRECTION LIST.
1ST BLDG INTERWEST I
11/27/2019 I
12/16/2019 12/17/2019 I REVISIONS REQUIRED I I COMPLETE REVIEW - PLEASE SEE ATTACHMENTS.
COMPLETE (2 WK) I
COMPLETE
2ND
(1 WK) I BLDG INTERWEST I
1/21/2020 I 1/28/2020 I 1/27/2020 I APPROVED I I WEB PERMIT --DN ATTAR MENTS.IGITAL REVIEW. LANS LOCATED
Printed: Wednesday, July 05, 2023 10:07:28 AM 12 of 15
WsYsrEMS
2ND BLDG NS —
ETRAKIT (1 WK)
JAKE FUSON 1 1/21/2020 1 1/28/2020 1 1/31/2020 1 REVISIONS REQUIRED
-PROVIDE DETAILED DRAWINGS FOR THE WORK
AT THE FRONT ENTRY/CURB RAMP AREA. SHOW
DIMENSIONS OF CURB RAMP LANDINGS, DOOR
LANDINGS/MANEUVERING CLEARANCES,
ACCESSIBLE ROUTE WIDTHS AND ALL
APPROPRIATE SLOPES AT THIS AREA
REVISE THE ACCESSIBLE SINK DETAIL H9/A500 TO
SHOW THE REQUIRED KNEE CLEARANCE
DIMENSIONS THAT ARE NOT SHOWN. THIS
WOULD INCLUDE THE 29" HEIGHT REQUIRED AT
THE FRONT OF THE COUNTER AND THE 11"
MINIMUM DEPTH. I HAVE ATTACHED A SNIPPET
FROM THE CODE BOOK THAT SHOWS THESE
DIMENSIONS
NO CORRECTION LIST CREATED DUE TO MINOR
SCOPE OF CORRECTIONS. CORRECTIONS SENT VIA
EMAIL.
3RD BUILDING — JAKE FUSON 2/3/2020 2/10/2020 2/4/2020 APPROVED
ETRAKIT (1 WK)
1ST BLDG NS - JAKE FUSON 4/14/2020 4/15/2020 4/14/2020 APPROVED REVISION 1 - REVISION 1 - ELECTRICAL CHANGES. ADDED
ETRAKIT (1 DAY) ELECTRICAL CIRCUITRY AND REVISED PANEL SCHEDULES.
Printed: Wednesday, July 05, 2023 10:07:28 AM 13 of 15
WsYsrEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
11/24/2019
EtrakitPublicReg
IST SUBMITTAL -PLAN
Architectural Plan Check
1
SET
Set 11-15-2019.pdf
DOC
11/24/2019
EtrakitPublicReg
IST SUBMITTAL - TITLE
calculations 11-22-
1
24 CALCULATIONS
19.pdf
DOC
1/17/2020
EtrakitPublicReg
2ND SUBMITTAL -
calculations 1-8-20 pc
1
ENERGY REPORT
corr.pdf
2ND SUBMITTAL -
DOC
1/17/2020
EtrakitPublicReg
INDOOR LIGHTING
calculations Rx controls
1
1-8-20 pc corr.pdf
ENERGY FORMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 13 of 15
WsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 14 of 15
WsYsrEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
Cart Mart Digital Plan
DOC
1/17/2020
EtrakitPublicReg
2ND SUBMITTAL - PLAN
Check Re -Submittal
1
SET
-01-
17-2020.pdf
DOC
1/17/2020
EtrakitPublicReg
ELECTRICAL FIXTURE
Cart Mart
1
SPECIFICATIONS
Submittal_opt.pdf
DOC
1/17/2020
EtrakitPublicReg
LIGHTING CONTROL
LIGHTING
1
SPECIFICATIONS
CONTROLS.pdf
PATH OF TRAVEL
DOC
1/17/2020
EtrakitPublicReg
UPGRADE
Path travel
1
determination. pdf
DETERMINATION
2ND SUBMITTAL - CITY
DOC
1/17/2020
EtrakitPublicReg
CORRECTION
PCR_City
1
Quinta_01-17-
RESPONSES
2ND SUBMITTAL -
PCR lnterwest
DOC
1/17/2020
EtrakitPublicReg
INTERWEST
Consulting Group_01-17
1
CORRECTION
-2020.pdf
RESPONSES
Cart Mart Digital Plan
DOC
2/3/2020
EtrakitPublicReg
3RD SUBMITTAL - PLAN
Check Re -Submittal
1
SET
-02-
03-2020.pdf
DOC
12/17/2019
INTERWEST
1ST REVIEW INTERWEST
201910716 (BCOM2019-
0
COMMENTS
0069) PC1.docx
La Quinta - 201910716;
DOC
12/17/2019
INTERWEST
1ST REVIEW INTERWEST
BCOM2019-0069 -
0
TRANSMITTAL
Invoice 55727.pdf
2ND REVIEW -
201910716 (BCOM2019-
DOC
1/27/2020
INTERWEST
INTERWEST APPROVAL
0
0069) PCF.docx
TRANSMITTAL
La Quinta - 201910716;
DOC
1/27/2020
INTERWEST
2ND REVIEW -
BCOM2019-0069 -
0
INTERWEST INVOICE
Invoice 56863.pdf
Printed: Wednesday, July 05, 2023 10:07:28 AM 14 of 15
WsYsrEMS
Printed: Wednesday, July 05, 2023 10:07:28 AM 15 of 15
WsYsrEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BCOM2019-0069 - 1ST
DOC
1/9/2020
JAKE FUSON
1ST REVIEW COMPLETE
REVIEW COMPLETE
1
CORRECTION LIST
CORRECTION LIST.pdf
BCOM2019-0069 -
DOC
2/4/2020
JAKE FUSON
APPROVED PLAN SET
APPROVED PLAN
1
SET.pdf
CERTIFICATE OF
DOC
4/10/2020
JAKE FUSON
ACCEPTANCE - NRCA-
Cart Mart -
1
NRCA LTI 02_A.pdf
LTI-02-A
— —
CERTIFICATE OF
DOC
4/10/2020
JAKE FUSON
INSTALLATION - NRCI-
Cart Mart -
1
NRCI_LTI_01_E.pdf
LTI-01-E
CERTIFICATE OF
DOC
4/10/2020
JAKE FUSON
INSTALLATION - NRCI
Cart Mart -
1
NRCI_LTI_02_E.pdf
LTI-02-E
BCOM2019-0069 -
DOC
4/14/2020
JAKE FUSON
REVISION 1 - APPROVED
REVISION 1 - 1ST
1
ELECTRICAL PLAN
SUBMITTAL ELECTRICAL
PLANS.pdf
BCOM2019-0069 -
DOC
5/22/2020
JAKE FUSON
CERTIFICATE OF
CERTIFICATE OF
1
OCCUPANCY
OCCUPANCY.pdf
BCOM2019-0069 - 3-25-
BCOM2019-0069 - 3 -25 -
DOC
3/25/2020
KOHL HETRICK
2020 - FIRE
2020 - FIRE
1
CORRECTIONS (1).pdf
CORRECTIONS (1).pdf
Printed: Wednesday, July 05, 2023 10:07:28 AM 15 of 15
WsYsrEMS
Certificate of Occupancy
Design & Development Department
This Certificate is issued pursuant to the requirements of Chapter 1 Section 111 of the California
Building Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 78525 HIGHWAY 111 STE 200
Use classification: MERCANTILE - GOLF CART RETAIL SALES FACILITY
Occupancy Group: M
Code Edition: 2016
By:
Date:
Building Official:
JAKE FUSON
5/22/2020
AJ ORTEGA
Type of Construction: VA
Sprinkler Installed: YES
Owner of Building:
Address:
City, ST, ZIP:
JOUS PLACE
Building Permit No.: BCOM2019-0069
Land Use Zone: CR
Occupant Load: 238
JDD
78555 HIGHWAY 111
LA QUINTA, CA 92253
PERM IT/CASE#:
FACILITY NAME:
FACILITY ADDRESS:
RIVERSIDE COUNTY FIRE DEPARTMENT
OFFICE OF THE FIRE MARSHAL
CITY OF LA QUINTA
78-495 CALLE TAMPICO, Lam, QUINTA CA 92253
MAIN: 760-777-7000 DIRECT: 760-777-7074
FIRE AND LIFE SAFETY
INSPECTION LOG/ORDER TO COMPLY
BCOM2019-0069
CART MART
78525 HIGHWAY 111
NOTICE NO: 1
DATE: 3/25/2020
CONTACT: CHARLES PRUITT
PAGE OF
The items below are in violation of or shall meet additional requirements of one or more of the following:
❑ CALIFORNIA FIRE CODE
❑ CALIFORNIA BUILDING CODE
❑ LA QUINTA MUNICIPAL CODE
❑ NFPA STD.
❑ CCR TITLE
❑ OTHER
THE FIRE FINAL INSPECTION IDENTIFIED THE FOLLOWING CORRECTIONS REQUIRED:
1) The new electrical panels being installed for use need to be complete and provided with all required labeling and panel
schedule.(CFC 605.3.1 & CEC)
2) Signage and/or marking shall be provided around electrical service panels and distributions to identify no storage within
36 -inches infront of these pieces of equipment. (CFC 605.3)
3) Exterior and Interior doors giving direct access to electrical rooms shall be provided with textual signage "ELECTRICAL
ROOM". (CFC 605.3.1)
4) All outlets and switches require face plates or blank covers be installed. (CEC)
5) "This Door to Remain Unlocked ..." signage is required above the main entry door that has a key -operated locking
device from the inside. (CBC 1010.1.9.3)
*Tenant access keys, appropriately labeled, shall be provided at a later date to be installed in the existing Knox Box
located on the building.
The listed violations/requirements shall be corrected immediately.
A re -inspection will be conducted on or after REQUEST 2020 .
FAILURE TO COMPLY MAY RESULT IN LEGAL ACTION AND/OR SIGNIFICANT DELAYS FOR APPROVAL.
Received By: charles_a_pruitt@yahoo.com
Fire Inspector: Kohl Hetrick
Signature:
Radio I.D.: I-120
IF YOU HAVE ANY QUESTIONS OR NEED ADDITIONAL INFORMATION, PLEASE CALL 760-777-7074.