BSOL2022-0594Permit Details PERMIT NUMBER City of La Quinta BSOL2022-0594 Description: ELMGREN/3.96kW PV SYSTEM - (11) 360W PANELS/(1) INVERTER Type: SOLAR (WEB) Subtype: RESIDENTIAL LESS THAN Status: FINALED 10KW Applied: 9/20/2022 ECON Approved: 12/1/2022 JFU Issued: 12/1/2022 ONLINE Finaled: 1/18/2023 JAN Expired: Parcel No: 774115005 Site Address: 53620 AVENIDA OBREGON LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA AT VALE LA QUINTA Block: 188 Lot: 5 UNIT 19 Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Valuation: $11,000.00 Occupancy Type: Construction Type: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 3.96kW SOLAR ARRAY - (11) 360W PANASONIC EVPV360K PANELS + SOLAREDGE P400 POWER OPTIMIZERS W/ (1) SOLAREDGE SE3800H-US INVERTER [220SF] 2019 CALIFORNIA BUILDING CODES. Process Summary 4 72 Applied to Approved Approved to Issued Issued to Finaled ADDITIONAL SITES L ■ ; I 1 I CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL JAKE FUSON 12/1/2022 12/1/2022 NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND PERMIT IS READY TO ISSUE. CONDITIONS CONTACTS NAME TYPE NAME ADDRESS1 CITY STATE ZIP PHONE FAX EMAIL APPLICANT HOT PURPLE INC DBA HOT PURPLE ENERGY 810 N Farrell Dr PALM SPRINGS CA 92263 (0)-0 spencer@hotpurpleen ergy.com CONTRACTOR HOT PURPLE INC DBA HOT PURPLE ENERGY 810 N Farrell Dr PALM SPRINGS CA 92263 (0)-0 spencer@hotpurpleen ergy.com OWNER STEVEN L ELMGREN (0)-0 FINANCIAL INFORMATION Printed: Monday, July 24, 2023 5:29:22 PM 1 of 3 CRWSYSTE S Permit Details City of La Quints PERMIT NUMBER BSOL2022-0594 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD ■ ■ PAID BY CLTD BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 12/1/22 WEB13735 763033103 CREDIT HOT PURPLE INC ECON Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM LESS THAN 10KW 101-0000-42403 0 $27.79 $27.79 12/1/22 WEB13735 763033103 CREDIT HOT PURPLE INC ECON PV SYSTEM LESS THAN 10KW PC 101-0000-42600 0 $27.79 $27.79 12/1/22 WEB13735 763033103 CREDIT HOT PURPLE INC ECON Total Paid for ELECTRICAL 2021: $55.58 $55.58 PERMIT ISSUANCE 101-0000-42404 0 $105.60 $105.60 12/1/22 WEB13735 763033103 CREDIT HOT PURPLE INC ECON Total Paid for PERMIT ISSUANCE: $105.60 $105.60 RECORDS MANAGEMENT FEE 101-0000-42416 0 $11.00 $11.00 12/1/22 WEB13735 763033103 CREDIT HOT PURPLE INC ECON Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00 ENHANCEMENT FEE TECHNOLOGY 502-0000-43611 I 0 $5.00 $5.00 12/1/22 WEB13735 763033103 CREDIT HOT PURPLE INC ECON Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00 TOTALS: $178.18 $178.18 INSPECTION' SEQID INSPECTION TYPE INSPECTOR SCHEDULED DATE COMPLETED DATE RESULT REMARKS NOTES SOLAR FINAL** JAN 1/17/2023 1/18/2023 APPROVED eTRAKiT Inspection Request 1/13/2023 2:45 PM HOT PURPLE INC DBA HOT PURPLE ENERGY SOLAR ONLY Contact Name: HOT PURPLE INC DBA HOT PURPLE ENERGY Site Address: 53620 AVENIDA OBREGON Phone: 7608983939 e-Mail: spencer@hotpurpleenergy.com Printed: Monday, July 24, 2023 5:29:22 PM 2 of 3 CRWSYSTE S Permit Details City of La Quinta PERMIT NUMBER BSOL2022-0594 PARENT PROJECTS REVIEWS REVIEW TYPE REVIEWER SENT DATE DUE DATE RE DUAR EED STATUS REMARKS NOTES 1ST BLDG NS - ETRAKIT (1 DAY) JAKE FUSON 9/20/2022 9/21/2022 12/1/2022 APPROVED ATTACHMENTS Attachment Type I CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 9/20/2022 Etrakit Contractor 1ST SUBMITTAL SOLAR PLAN 53620 Avenida Obregon - PLAN SET - Rev A.pdf 1 DOC 12/1/2022 JAKE FUSON SOLAR PLAN (APPROVED) BSOL2022-0594 - SOLAR PLAN (APPROVED).pdf 1 Printed: Monday, July 24, 2023 5:29:22 PM 3 of 3 CRWSYSTEMS f .. . . a Calle Colima Calle Colima 1 ra Revisions: Date: Rev A 7/28/22 1 " 141 ' . •• _ • + , �` * l : ' ► - r "' - A a w n a a I _ y 0 o BSOL2022-0594 3.96kW SOLAR ARRAY - (11) 360W PANASONIC coQ d EVPV360K PANELS + N SOLAREDGE P400 POWER OPTIMIZERS W/ — Michael Rango TliC�tAEl %ZGGY6gV 760.322.4433 Lic. No.940550 M ..- ---,-- ,...— — _ .-- • , ti. - _� _. - w. , . _ �,,� i�':�. ' i — s _ I t. `•- � , .,, ' r _ _ — • _ .�- f ■- ! - . � �, 4.0,Y,ti + 810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www.HotPurpleEnergy.com n m c m 0 9 1 SOLAREDGE ( ) SE3800H-US INVERTER [220SF] 2019 a CALIFORNIA BUILDING ti CODES. } •I Q a N Things Mobile =talling service.,. o Q o = a CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE12/01/2022 BY IF �. �- " ............................. j �[ • _ INTEGRA TOR: H P 0 Hot Purple Energy A _,._�I — . '% ` r _ �. ; _ ' • • '-' —F411. • , she Calle Arroba Calle Armin Calle Arroba Calle Arroba • ' GENERAL NOTES: DESCRIPTION OF WORK: o Title: iv Hafif Residence E COVER SHEET 73 53620 Avenida Obregon La Quinta, CA 92253 1. ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED LICENSED ELECTRICIAN AND APPRENTICES WORKING UNDER ROOF MOUNTED PHOTOVOLTAIC (SOLAR ELECTRIC) INSTALLATION TILT MOUNTED @ 5° FACING THE DIRECT SUPERVISION OF A LICENSED ELECTRICIAN. AN AZIMUTH OF 180° CONSISTING OF (11) PANASONIC EVPV360K - 360 WATT MODULES (3.96Kw). 2. ALL SOLAR MODULES SHALL BE UL LISTED 1703 AND CEC APPROVED. ALL INVERTERS SHALL BE UL LISTED 1741 SA RACK MOUNTING SYSTEM IS UNIRAC SOLARMOUNT ALUMINUM SUPPORT RAILS AND FAST JACK CERTIFIED AND CEC APPROVED. ALL ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED AND APPROVED SOLAR STANCHIONS. FOR IT'S PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR EQUIPMENT SHALL MEET INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: APPROPRIATE NEMA STANDARDS. CEC 2019 - ARTICLE 690, 705,706 AND OTHERS 3. THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY SERVICE PROVIDER. ANTI-ISLANDING CPC 2019 PROTECTION IS A REQUIREMENT OF UL1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PHOTOVOLTAIC CBC 2019 SYSTEM WHEN THE UTILITY GRID IS NOT IN OPERATION. CMC 2019 CFC 2019 CRC 2019 4. PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS AND APPROVALS BY THE LOCAL LA QUINTA MUNICIPAL CODE AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. ALL CONSTRUCTION SHALL COMPLY WITH THE 2019 CALIFORNIA RESIDENTIAL, MECHANICAL, ELECTRICAL, PLUMBING, GREEN BUILDING AND ENERGY CODES AND THE LA QUINTA MUNICIPAL CODE DRAWING SHEETS: Checked by: BD 5. THE METHOD OF MOUNTING SHALL BE DONE IN ACCORDANCE WITH THE RACKING MANUFACTURER TO MEET DEAD COVER SHEET PV-0.0 LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. PHOTOVOLTAIC MODULES WILL BE SECURED AND MOUNTED ON OPTIMIZER STRINGING NOTES NOT FOR PERMITTING) PV-0.0 (2) THE ROOF AS SPECIFIED ON THE STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED BY THE SITE PLAN PV 1.0 PHOTOVOLTAIC SYSTEM OR INSTALLATION. SYSTEM PERFORMANCE NOTES )NOT FOR PERMITTING) PV-1.0 (2) ROOF PLAN PV-2.0 6. ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR THE SITE CONDITIONS. SINGLE LINE DIAGRAM PV-3.0 MOUNTING DETAIL PV-4.0 7. ALL ROOFING REPAIRS MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF AND ALL WORK SHALL BE IN WARNING LABELING PV-5.0 ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTALLATION REQUIREMENTS. SPECIFICATION SHEETS: Date: 7/25/22 Scale: NTS Job Number: 22157 Sheet Number: P` V ,—O . Sheet 0 8. TO BE INSTALLED IN SUCH A MANNER THAT IS DISCREET AND DOES NOT DETRACT FROM THE HOMES ARCHITECTURE EVPV360K MODULE SE3800H-US INVERTER UNIRAC CERTIFICATION OPTIMIZER / STRINGING (INSTALLATION NOTES NOT FOR PERMITTING) 1 13 25 37 49 61 2 14 26 38 50 62 3 15 27 39 51 63 4 16 28 40 52 64 5 17 29 41 53 65 6 18 30 42 54 66 7 19 31 43 55 67 8 20 32 44 56 68 9 21 33 45 57 69 10 22 34 46 58 70 11 23 35 47 59 71 12 24 36 48 60 Panel S/N: n 0 n Revisions: Date: Rev A 7/28/22 AVENIDA OBREGON (1 1) PANASONIC EVPV360K 360 WATT MODULE ARE SHOWN 3.96kW DRIVEWAY 113 PROPERTY LINE PROPERTY LINE SITE PLAN KEYNOTE: EXISTING ELECTRICAL 1.1 200A MAIN ELECTRICAL PANEL NEW ELECTRICAL (ADJACENT TO MSP) 2.1 SYSTEM AC DISCONNECT 2.2 SE3800H-US PV INVERTER SIT��EE LEGEND FIRE EASEMENT/ACCESS CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE12/01/2022 BY jF Michael Rango JKiL�i .. t jZG�t��O 760.322.4433 Lic. No. 940550 Lu Z 810 N. Farrell Drive co U CV ._ w 0 U ui c N Q CV G7 CD a N- License No. 940550 a 2 Hot Purple Energy Hafif Residence SITE PLAN 0 Is _o 0 co C a) N cy) LC) La Quinta, CA 92253 Drawn by: MJR Checked by: BD Date: 7/25/22 Scale: 1"=15' Job Number: 22157 Sheet Number: PV-1.0 Sheet SYSTEM PERFORMANCE (INSTALLATION NOTES NOT FOR PERMITTING) INVERTER M/N INVERTER M/N INVERTER M/N INVERTER S/N INVERTER S/N INVERTER S/N INPUT # 1 2 INPUT # 1 2 INPUT # 1 2 STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) STRING CONFIG (1 column each MPPT) AZIMUTH/ ORIENTATION AZIMUTH/ ORIENTATION AZIMUTH/ ORIENTATION SLOPE/TILT SLOPE/TILT SLOPE/TILT VOC @ Jbox VOC @ Jbox VOC @ Jbox VOC © Inverter VOC © Inverter VOC @ Inverter V+ to Gnd V+ to Gnd V+ to Gnd V- to Gnd V- to Gnd V- to Gnd AC L 1-L2 AC L 1-L2 AC L 1-L2 AC L1-N AC Ll-N AC Ll-N AC L2-N AC L2-N AC L2-N WATTS @ TIME OF DAY WATTS @ TIME OF DAY WATTS @ TIME OF DAY AMBIENT TEMP. AMBIENT TEMP. AMBIENT TEMP. WEATHER SUNNY PARTLY CLOUDY CLOUDY WEATHER SUNNY PARTLY CLOUDY CLOUDY WEATHER SUNNY PARTLY CLOUDY CLOUDY AC POWER AC POWER AC POWER CREW NOTES: Revisions: Date: NO ROOF VENTS, ATTIC VENTS OR OTHER NECESSARY BUILDING COMPONENTS MAY BE COVERED OR ALTERED BY THE INSTALLATION OF THE NEW PV ARRAY 2.1 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE12/01/2022 BY J F 2' 0' 2.5' 10' 20' 5'' 7 MOUNT PLAN KEYNOTE: RACK MOUNT COMPONENTS 1.1 UNIRAC ALUMINUM SUPPORT RAIL 1.2 FAST JACK SOLAR STANCHIONS STRUCTURAL 2.1 ROOF SUPPORTS 2x10 ENGINEERED TRUSS/JOIST (24" O.C.) 1. VERIFY RAFTER SPACING IN THE FIELD BEFORE ATTACHING MOUNTS ROOF. 2. ENSURE THAT MOUNTING LAGS PENETRATE CENTER OF RAFTERS AND MAKE STRUCTURAL CONNECTION TO THE RAFTERS. 3. STRUCTURAL CONNECTION TO ENGINEERED TRUSS SHALL BE MADE BY 3-1 /2" X 5/16" STAINLESS STEEL LAG SCREWS 3" MIN. EMBEDMENT. 4. ALL MOUNTS SHALL BE 20" FROM ALL VALLEYS. 5. PHOTOVOLTAIC MODULES SHALL HAVE 2.2 MOUNTS (LAG SCREWS) PER PANEL. 6. (E) ROOF STRUCTURE IS FLAT 2X10 ENGINEERED TRUSS/JOIST 24" O.0 TYP. 7. (E) ROOFING MATERIAL IS 1 LAYER OF HOT MOP OVER 1 LAYER OF 30LB. FELT PAPER AND 1 /2" OSB PLYWOOD DECKING. 8. MODULE DIMENSIONS 67.7" x 40.0" 48" SPACING BETWEEN MOUNTS IS TYPICAL - MAX SPAN 6' Analysis of dead load we icitit added to roof by installation of solar array Array di Panasonic EVPV3601C No. of Solar modules Totel weight of modules Weight of each Solar Rack set No. of rack sets Td al weight of rack sots 43.00 Pounds 11 473 pounds 10 pounds 11.0 I05 pounds Total weight of solar array 570 pounds Height of each module Width of each module Area of we module Area of entire solar array Weight of solar array per unit area of roof No. of stanchions connected to roof Joist raters Wright loading per stanchion 5.85 feet 3.33 feet 22 4.4 18.8 square feet 207.0 Square feet 24 24.1, poundslsquare Got pout dslcennecti on mounts per module lags per module with SIC hooks Rev A 7/28/22 Michael Rango JKiLk ,. t jZGTt4�0 760.322.4433 Lic. No. 940550 O Lu License No. 940550 a 2 Hot Purple Energy ROOF PLAN Drawn by: MJR 53620 Avenida Obregon La Quinta, CA 92253 Checked by: BD Date: 7/25/22 Scale: 1"=5' Job Number: 22157 Sheet Number: PV-2.o Sheet Revisions: Date: Rev A 7/28/22 USE THIS ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISED SPECFIED ID WI RE AND CONDUIT SCHEDULE AMPS MULTI- FLIER REQ. AMPS WIRE GUAGE 90C WIRE AMPS 90C TEMP DERATE FACTOR WIRE DEBATED AMPS WIRE COLUMN 75C WIRE AMPS 75C WIRE TYPE USED GND SIZE COND. QNTY CONDUIT FILL FACTOR CONDUIT SIZE CONDUIT TYPE A MODULETOJ-BOX 15 1.56 23.40 10 40 0.71 28.40 10 35 RHW-2 6 2 1 NA FREE AIR * B J-BOX TOSE380BH-US INVERTER 15 1.56 23.40 10 40 0.81 32.40 10 35 THWN-2 8 2 1 0.50 METALLIC C SE3800H-US TO MSP 16 1.25 20.00 10 40 0.81 32.40 10 35 THWN-2 8 2 1 0.50 METALLIC * DC ICS VALUES ACCOUNT FOR 125% CLOUD ENHANCEMENT(NEC 690.8(A)(1)) 3,960 WATT DC (3,713 WATT AC) INDIVIDUAL MODULE RATING: SOLAR ELECTRIC ARRAY PTC = 341.0 WATTS 11 PANASONIC 360 WATT MODULES Voc = 44.0 VDC MODEL NO. EVPV360K Isc = 10.37 AMPS 11 x 341.0 PTC x 99% EFF = 3.713 kW AC 1 STRING OF 11 0 0 0 0 0 0 11 O 0 J-BOX 1 L Rooftop conduit shall be installed a minimum of 7/8" above the rooftop. SOLAREDGE POWER OPTIMIZER P400 RATED DC INPUT POWER - 400 WATTS MAXIMUM INPUT VOLTAGE - 80 VDC MPPT RANGE - 8 TO 80 VDC MAXIMUM INPUT CURRENT - 12.5 ADC MAXIMUM OUTPUT CURRENT - 15 ADC STRING LIMITATIONS - 8 TO 25 OPTIMIZERS, 5250 WATTS STC PER STRING MAXIMUM AC OUT PV DC IN 0-0 V o-0 6-o-o SOLAREDGE SE3800H-US GRID -TIE INVERTER INPUT: 400 TO 480 VDC OUTPUT: 3800 WATTS MAX OUTPUT EFFICIENCY: 99% 240 VAC, 16 AMPS MAX INTEGRATED GFCI AND DC DISCONNECTS SolarEdge systems are not solidly grounded (functional grounded) PV systems as permitted under Article 690.47. NOTES: EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690, 705 , 706 AND OTHERS. (N) PV DISCONNECT ADJACENT TO INVERTER/MSP 30A/240V 1. EACH PHOTOVOLTAIC DISCONNECTING MEANS PER NEC 690.14 SHALL BE PARENTALLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC DISCONNECT. 2. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS -TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION" 3. PROVIDE WARNING SIGN PER NEC 690.54 AT THE PV AC DISCONNECTING MEANS: 1. INVERTER OUTPUT CURRENT 2. INVERTER OUTPUT VOLTAGE 4. LABEL PANEL "PHOTOVOLTAIC POWER SOURCE CONNECTED" PER NEC 705-10, AND IDENTIFY BACKFED BREAKERS PER NEC 690-64(b)7. 5. INDIVIDUAL INVERTERS ARE GROUNDED THROUGH THE MANUFACTURES NRTL TESTED AND CERTIFIED AC CABLE. 6. ALL EQUIPMENT SHALL BE PROTECTED FROM PHYSICAL DAMAGE. /77 SE3800H-US = 16A x 1.25 = 20A CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 12/01 /2022 BY IF 200A x 1.2 = 240A 240A - 200A = 40A 20A <= 40A (E) MAIN SERVICE PANEL 200A BUSS, 120/240V, 1PH, 3W 10 0 0 0 200A BREAKER o 20A MSP /77 7. ALL LIVE PARTS IN SYSTEM, INCLUDING FUSES ARE NOT ACCESSIBLE TO ANYONE OTHER THAN QUALIFIED PERSONS. 8. ALL PV SYSTEM EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY. 9. ALL EXTERIOR WIRING MATERIAL SHALL BE SUITABLE FOR A SUN EXPOSURE AND WET LOCATIONS. 10. REMOVAL OF THE INVERTER SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GEC AND/OR OUTPUT CIRCUIT CONDUCTOR. 11. CONNECT THE UTILITY WIRES TO THE LINE SIDE OF AC DISCONNECT WHEN INSTALLED. 12. ELECTRICAL INSTALLATION IN ACCORDANCE WITH 2019 CALIFORNIA ELECTRIC CODE & NEC 2020 705.13. 13. BACKFED BREAKER SHALL BE LOCATED AT THE BOTTOM OF THE SERVICE PANEL OR AT THE END OF THE CIRCUIT. 14. ANY LOADS RELOCATED TO A BU LOADS PANEL BEYOND SIX FEET SHALL REQUIRE AFC! PROTECTION. Michael Rango JKickxat JZA44.g17 760.322.4433 Lic. No. 940550/ O cc Lu N a) N.V o no Q co a)01- L (n D) I LL C• Z o CO oolTo v License No. 940550 E E O0 O a) a) C c aLULu i_0 Q Q D- 0- 0 0 2 S o � c 0 a T Hafif Residence L.I. 0 I0 z_ J uJ 0 0 VJ Drawn by: MJR Hot Purple Energy 53620 Avenida Obregon La Quinta, CA 92253 Checked by: BD Date: 7/25/22 Scale: NTS Job Number: 22157 Sheet Number: PV-3.0 Sheet Revisions: Date: Rev A 7/28/22 1.4 1.6 1.7 1.9 2.2 �\ 2.3 / '/l // / //// -l'// /-/(//./'/yl /'///l'/-// /7I//' /// N N 1.8 '0/7'iy / // /'/ /, /'/ /I i /'/'// /'/ / /,/'//, 1.3 1.5 MOUNT DETAIL KEYNOTE: RACK MOUNT COMPONENTS 1.1 PHOTOVOLTAIC MODULE 1.2 MODULE CLAMP 1.3 UNIRAC "SOLARMOUNT" SUPPORT RAIL 1.4 SS RAIL T-BOLT AND NUT 1.5 UNIRAC L-FOOT 1.6 ADJUSTABLE ALL TREAD 1.7 FAST JACK SOLAR STANCHION (4.5" - 7" typical) 1.8 3.5" SS LAG SCREWS (3" minimum embedment ) 1.9 OATEY FLASHING STRUCTURAL 2.1 HOT MOP 2.2 30LB FELT PAPER 2.3 1 /2" OSB ROOF DECKING 2.4 2 x 10 ENGINEERED TRUSS (RAFTER) 16" O.C. TYP. 1\ 5-7 DEGREE TILT DETAIL Scale: 1" = 1' CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE 12/01 /2022 BY IF N Michael Rango7KjLf%A. t jZG�t�g0 760.322.4433 Lic. No. 940550 4= Lu Z co a) N CV U C 0) 0 1 < M a)U� (p U- c N z 07, E o aN. License No. 940550 a 2 Hot Purple Energy J_ L1J 0 cp Z O L1J Q ▪ (6 ▪ = < Drawn by: MJR La Quinta, CA 92253 Checked by: BD Date: 7/25/22 Scale: 1"=5' Job Number: 22157 Sheet Number: PV-4.0 Sheet CONTRACTOR TO PROVIDE A PERMANENT PLACARD OR DIRECTORY DENOTING ALL ELECTRICAL POWER SOURCES ON THE PREMISES. THE PLACARD SHALL BE INSTALLED IN EACH SERVICE EQUIPMENT LOCATION AND AT LOCATION OF ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING INTERCONNECTED. CEC ARTICLES 690.56(B) AND 705.10. FORMAT: WHITE LETTERING ON A RED BACKGROUND, MINIMUM 3/8" HEIGHT, ALL LETTERS SHALL BE CAPITALIZED, AERIAL OR SIMILAR FONT, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. NOTE: LABELS AND PLACARDS MAY NOT BE HANDWRITTEN PER CEC 101.21 (B) (2) SE3800H-US Revisions: Date: Rev A 7/28/22 WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE Michael Rango Micitaat JZA44.10 760.322.4433 Lic. No. 940550 INTEGRA TOR: 810 N. Farrell Drive Palm Springs, CA 92262 (760) 322 - 4433 office License No. 940550 info@HotPurpleEnergy.com www. HotPurpleEnergy.com ADJACENT TO BACK FED BREAKER 705.12(B) (1) (3) (b) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE SUN IS CAU SUPPLYING 1 53620 AVENIDA ELECTRICITY 2 3 ION TO THIS BUILDING THROUGH PANELS ON ROOF OBREGON, LA QUINTA, CA 92253 4 SOLAR PLACE NEXT TO INVERTER AC DISCONNECTS 690.56(C) (3) H P 0 Hot Purple Energy WARNING: PHOTOVOLTAIC POWER SOURCE CONDUITS AND RACEWAYS EVERY 10' 690.31(G) (3) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED MAXIMUM VOLTAGE 480 V MAXIMUM CIRCUIT CURRENT 10.5 A MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC -TO -DC CONVERTER (IF INSTALLED) 15A PLACE ON MSP WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAYBE ENERGIZED IN THE OPEN POSITION p Title: iv Hafif Residence E WARNING LABELS 53620 Avenida Obregon La Quinta, CA 92253 1 PLACE ON DC DISCONNECT DC DISCONNECTS AND J-BOXES PV SYSTEM AC DISCONNECT WARNING - DUAL POWER SOURCE SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM MAX AC CURRENT : 16 A ACVOLTAGE:240V r- SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN LEGEND: n SERVICE PANEL (YOU ARE HERE) E SYSTEM AC DISCONNECT 3 PV INVERTER ® ROOF MOUNTED SOLAR (Igib HOT PURPLE ENERGY O 760.322.4433mber: PLACE ON SYSTEM DISCONNECTS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO ARRIC PV PANELS 166 SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE DATE12/01/2022 By JF Checked bv: BD J CEC 690.56(C)(1)(A) Date: 7/25/22 Label for PV Systems that shut down the array and the conductors leaving the array. The title "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" shall utilize capitalized characters with a minimum height of 9.5 mm )3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (316 in.) in black on white background. Scale: NTS Job Number: 22157 PV-5.O Sheet EverVo EVERVOLT" SOLAR MODULE BLACK SERIES Panasonic EverVo EVERVOLT" SOLAR MODULE BLACK SERIES Panasonic 370W / 360W TRUST. BUILT IN. The Panasonic Adv initaIr Higher Module Efficiency Superior module efficiency of 21.2% and 20.6%, -L� respectively, allows maximum power production with less roof space. With one of the industry's Lowest annual degradation rates, power output of at least 92% is guaranteed after 25 years. AllGuard and TripleGuard 25-Year Warranty' A long-term warranty is only as reliable as the company behind it. AllGuard and TripleGuard 25-year warranties cover EverVolt panels for performance, product, parts and labor for 25 years. Whether in year three or year 25, your Panasonic warranty will be there when you need it. High Efficiency in High Temperatures Produce more energy throughout the day even on the hottest days in the warmest climates. EverVolt solar panels outperform others when temperatures rise due to our industry -leading 0.26%/°C temperature coefficient. Heterojunction Cell Technology Half -cut cells with heterojunction technology minimizes electron loss, maximizes conversion efficiency, and produces considerably higher power output over conventional panels. Durability & Quality Assurance N-type cells result in minimal Low Induced degradation (LID) and Potential Induced degradation (PID), which supports reliability and longevity. As a solar pioneer for over 40 years, Panasonic EverVolt solar panels are backed by innovation, experience and a brand you can trust. Improved Performance When Shaded Continuous power production in shaded areas for greater energy yields and output. More sunlight absorption means more clean power to your home. Panasonic Panasonic Life Solutions Company of America Two Riverfront Plaza, Newark, NJ 07102 panasonicHIT@us.panasonic.com us/solar TRIPLE GUARD WARRANTY YrAf` * PRODUCT * * TABOR All Rights Reserved 0 2021 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice RS211337DS-R3 370W / 360W TRUST. BUILT IN. "ELECTRICAL SPECIFICATIONS Model EVPV370K EVPV360K Rated Power IPmaxl' Maximum Power Voltage IVpm) Maximum Power Current (lpml Open Circuit Voltage (Vocl Short Circuit Current (lscl Temperature Coefficient (Pmaxl Temperature Coefficient IVocl Temperature Coefficient (lscl NOCT CEC PTC Rating Module Efficiency Maximum System Voltage Maximum Series Fuse Watt Class Sorting 370W 37.4V 9.90A 44.1V 10.55A 360W 36.7V 9.82A 43.9V 10.49A -0.26 %/°C -0.24 %/°C 0.04 %/°C 44°C 1±2°C) 350.7W 340.3W 21.2% 20.6% 1000V 25 A -0/+10W MECHANICAL SPECIFICATIONS Junction Box Connector Type Cable Size / Type Max Snow Load (+)2 Max Wind Load I-12 Dimensions LxWxH Weight Pallet Dimensions LxWxH Quantity per Pallet / Pallet Weight Quantity per 40' Container 3-part, 3 bypass diodes. IP67 rated in accordance with UL 3730 Staubli MC4 PV-KBT4/KST4 14 mm1) in accordance with UL 6703 IP68 only when connected 4 mm2 solar cable, 1.0 m + 1.2 m in accordance with UL 4703 146 psI 17000 Pal' 83 psI 14000 Pal* 67.8 x 40.0 x 1.2 in 11721 x 1016 x 30 mml 43.0 lbs 119.5 kg) 70 x 42 x 48 in 33 pcs./1512 lbs. 1686 kg) 858 pcs *Test Load. Design Load should be multiplied by two thirds. OPERATING CONDITIONS AND SAFETY RATINGS Certifications Operating Temperature Limited Warranty Power Output in Year 1 Annual Degradation Power Output in Year 25 UL 61730 IEC61215-2:2016 [Hailstone 35mm] Fire Type 2 IUL 617301 Salt Mist DEC 61701] PIO (IEC 628041 Ammonia Resistance DEC 627161 -40°F to 185°F I-40°C to 85°C) 25' Yrs Workmanship and Power Output ILinearl" 98% 0.25% 92% NOTE: Values at standard test conditions)STC: air massAM1.5 irradiance 1000W/m2, temperature 25°C). Maximum power at delivery. For guarantee conditions, please check our guarantee document. " Installation need to be registered through ourwebsite www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (251 year Product workmanship. Otherwise, Product Workmanship will be only fifteen 115)years. 'Equipment must be installed by a Panasonic Authorized, Premium, or Elite installer and registered at www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (251 year AllGuard and TripleGuard warranty. ' Refer to installation manual for detailed mechanical loading information ***1st year 98%, after 2nd year 0.25% annual degradation to year 25. PERFORMANCE IARRANTY 100% 98% 90% 80% i Panasonic • Conventional More power over 25 years DIMENSIONS 67.75 [17211 31.5 [802] 17.9 [4551 + U " 39[t000] E .« 0.4310.00 4 iii±0.21 0.8110.02 t V [20.5±0.51 47 [12001 f - :T 1.8 [451 D.9 [22.51 24.5 [621] Measurements in in (mm] 2-1 118[301 DEPENDENCE ON IRRADIANCE 12 10 a s 6 4 2 1000W/r ' 05.0W/in2 600W/m2 0 10 20 30 Voltage IV] Reference data for model : EVPV370K Cell temperature : 77°F )25°C) • 40 50 NOTE: Specifications and information above may change without notice. ®CAUTION! Please read the installation manual carefully before using the products. Used electrical and electronic products must not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation. Panasonic Life Solutions Company of America Panasonic Two Riverfront Plaza, Newark, NJ 07102 panasonicHIT@us.panasonic.com na.panasonic.com/us/solar All Rights Reserved O? 2021 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice RS2 I037DS•R3 Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US ip solar v • • • • 0 O • W 12-25 YEAR I WARRANTY 9 • • • • Optimized installation with HD -Wave technology / Specifically designed to work with power optimizers / Record -breaking efficiency / Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 / UL1741 SA certified, for CPUC Rule 21 grid compliance solaredge.com / Extremely small / Built-in module -level monitoring / Outdoor and indoor installation / Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) S2f312i3nNI solar- • • I Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT 3000 10000 Rated AC Power Output 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom: Max. (211 - 240 - 264) i se se I ✓ i i Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) Vac AC Frequency (Nominal) 59.3 - 60 - 60.5", Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output- Current @208V 16 24 48.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer -less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240W' 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V0 - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 600ku Sensitivity Maximum Inverter Efficiency 99 992 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional'* Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1' Maximum / 14-6 AWG 1' Maximum /14-4 AWG DC Input Conduit Size / of Strings / AWG Range 1" Maximum / 1-2 strings / 14-6 AWG 1" Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -13 to +140 / -25 to +60"' (-40'F / -40'C option)°' 'F /'C Protection Rating NEMA 4X (Inverter with Safety Switch) ro For other regional settings please contact SolarEdge support m A higher current source may be used; the inverter will limit its input current to the values stated of Revenue grade inverter P/N: SEecoH-US000NNC2 "I For power de -rating information refer to: https://wwwsolaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Isl -40 version P/N: SEbowH-US000NNU4 ® SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2019/V01/ENG NAM. Subject to change without notice. RoHS Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 0 m 0 N m PV power optimization at the module -level s; Specifically designed to work with SolarEdge inverters / Up to 25% more energy Superior efficiency (99.5%) G' Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization / Fast installation with a single bolt / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) /' Module -level voltage shutdown for installer and firefighter safety I Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high - power 60-cell modules) P370 (for higher - power 60 and 72- cell modules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell modules) P405 (for high - voltage modules) P485 (for high - voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power71 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 1250 832) Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 -105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current Maximum Output Voltage 15 60 85 Adc Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC Safety Material RoHS FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 IEC62109-1 (class II safety), UL1741 UL94 V-0 , UV Resistant Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase Inverters Dimensions (INxLxH) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129x153x33.5 /5.1x6x1.3 129x153x29.5 /5.1x6x1.16 129x159x49.5/5.1x6.3x1.9 129x162x59/ 5.1x6.4x2.3 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr/ lb Input Connector P MC4(3) Single or dual MC4ai(4) MC4CCI Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Ranger') -40 - +85 / -40 - +185 °C / °F Protection Rating IP68 / NEMA6P Relative Humidity 0 -100 % (1) Rated power of the module at STC will not exceed the optimizer °Rated Input DC Power°. Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals. (5) For ambient temperature above +85°C / +185°F power de -rating is applied. Refer to Power Optimizers Temperature De -Rating Technical Note for more details. PV System Design Using a SolarEdge Inverter''"7) ring Length P320, P340, P370, P400, P401 Minimum St (Power Optimizers) P405, P485, P505 Maximum String Length (Power Optimizers) Maximum Power per String Parallel Strings of Different Lengths or Orientations Single Phase HD -Wave Single phase 8 6 25 5700 (6000 with SE7600-US - SE11400- US) 5250 Three Phase for 208V . rid 10 8 Three Phase for 277/480V grid 18 14 25 60000) 50te 127500D) Yes (6) For detailed string sizing information refer to: http✓/www.solaredge.com/sites/default/files/string-sizing-na.pdf (7) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W W solaredge.com O SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2020/V02/ENG NAM. Subject to change without notice. 41Vus RoHS Intertek SOLARMOUNT OUNIRAC SOLARMOUNT defined the standard in solar racking. Features are designed to get installers off the roof faster. Our grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Systems can be configured with standard or light rail to meet your design requirements at the lowest cost possible. The superior aesthetics package provides a streamlined clean edge for enhanced curb appeal. with no special brackets required for installation. Now Featuring: THE NEW FACE OF SOLAR RACKING Superior Aesthetics Package !OPP- 5-- 11111 [e] enN F R phaseG F FRONT TRIM ( END CAPS LOSE ALL OF THE COPPER & LUGS SMALL IS THE NEXT NEW BIG THING ENHANCED DESIGN & LAYOUT TOOLS System grounding through Enphase microinverters and trunk cables Light Rail is Fully Compatible with all SM Components Featuring Google Map Capabilities within U-Builder FAST INSTALLATION. SUPERIOR AESTHETICS OPTIMIZED COMPONENTS • VERSATILITY • DESIGN TOOLS • QUALITY PROVIDER SOLARMOUNT OPTIMIZED COMPONENTS INTEGRATED BONDING & PRE -ASSEMBLED PARTS Components are pre assembled and optimized to reduce installation steps and save labor time. Our new grounding & bonding process eliminates copper wire and grounding straps or bonding jumpers to reduce costs. Utilize the microinverter mount with a wire management clip for an easier installation. VERSATILITY ONE PRODUCT - MANY APPLICATIONS Quickly set modules flush to the roof or at a desired till angle. Change module orientation to portrait or landscape while securing a large variety of framed modules on flat, low slope or steep pitched roofs. Available in mill, clear and dark anodized finishes to outperform your projects financial and aesthetic aspirations. AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE Creating a bill of materials is just a few clicks away with U-Builder, a powerful online tool that streamlines the process of designing a code compliant solar mounting system. Save time by creating a user profile. and recall preferences and projects automatically when you log in. You will enjoy the ability to share projects with customers: there's no need to print results and send to a distributor, just click and share. N o BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATION :PUNIRAC INTEGRATED BONDING SPLICE BAR INTEGRATED BONDING MICROINVERTER MOUNT w/ WIRE MANAGEMENT INTEGRATED BONDING MIDCLAMP INTEGRATED BONDING L-FOOT w/ T-BOLT UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT i UNMATCHED EXPERIENCE CERTIFIED QUALITY TECHNICAL SUPPORT Unirac's technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports. stamped letters and technical data sheets greatly simplifies your permitting and project planning process. ENGINEERING EXCELLENCE CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001.2008. 14001.2004 and OHSAS 18001.2007. which means we deliver the highest standards for ht. form, and function. These certifications demonstrate our excellence and commitment to first class business practices. a I DESIGN TOOLS PERMIT DOCUMENTATION BANKABLE WARRANTY Dont leave your project to chance. Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are receiving products of exceptional quality. SOLARMOUNT is covered by a 10 year limited product warranty and a 5 year limited finish warranty. PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN s S stru ctu ra ENGINEERS March 30, 2021 Unirac 1411 Broadway Blvd. NE Albuquerque, NM 87102 Attn.: Unirac - Engineering Department Re: Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail Version PZSE, Inc. - Structural Engineers has reviewed the Unirac SOLARMOUNT rails, proprietary mounting system constructed from modular parts which is intended for rooftop installation of solar photovoltaic (PV) panels; and has reviewed the U- builder Online tool. This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail, SOLARMOUNT STANDARD rail, and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information, data and analysis contained within are based on, and comply with the following codes and typical specifications: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-16 2. 2019 California Building Code, by California Building Standards Commission. 3. 2018 International Building Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 4. 2018 International Residential Code, by International Code Council, Inc. w/ Provisions from SEAOC PV-2 2017. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES. 6. 2015 Aluminum Design Manual, by The Aluminum Association, 2015 Following are typical specifications to meet the above code requirements: Design Criteria: Attachment Spacing: Cantilever: Clearance: Tolerance(s): Installation Orientation: Ground Snow Load = 0 -100 (psf) Basic Wind Speed = 85 - 190 (mph) Roof Mean Height = 0 - 60 (ft) Roof Pitch = 0 - 45 (degrees) Exposure Category = B, C & D Per U-builder Engineering report. Maximum cantilever length is L/3, where "L" is the span noted in the U-Builder online tool. 2" to 10" clear from top of roof to top of PV panel. 1.0" tolerance for any specified dimension in this report is allowed for installation. See SOLARMOUNT Rail Flush Installation Guide. Landscape - PV Panel long dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the long side. Portrait - PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel is mounted on the short side. stru ctu ra ENGINEERS Components and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7-05, ASCE 7-10 & 7-16 Component and Cladding design. Notes: 1) U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not include roof capacity check. 2) Risk Category II per ASCE 7-16. 3) Topographic factor, kzt is 1.0. 4) Array Edge Factor YE = 1.5 5) Average parapet height is 0.0 ft. 6) Wind speeds are LRFD values. 7) Attachment spacing(s) apply to a seismic design category E or less. Design Responsibility: The U-Builder design software is intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, this U-builder software should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether the U-Builder Software is applicable to the project, and • Understand and determine the appropriate values for all input parameters of the U-Builder software. This letter certifies that the Unirac SM SOLARMOUNT Rails Flush, when installed according to the U-Builder engineering report and the manufacture specifications, is in compliance with the above codes and loading criteria. This certification excludes evaluation of the following components: 1) The structure to support the loads imposed on the building by the array; including, but not limited to: strength and deflection of structural framing members, fastening and/or strength of roofing materials, and/or the effects of snow accumulation on the structure. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. 3) The capacity of the solar module frame to resist the loads. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. — Structural Engineers Roseville, CA DIGITAL SIGNATURE 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 F 916.961.3965 VV www.pzse.com Experience I Integrity I Empowerment 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 916.961.3960 F 916.961.3965 \ www.pzse.com Experience I Integrity I Empowermen