BWFE2021-0358Permit Details
PERMIT NUMBER
City of La Quints BWFE2021-0358
Description: HAFIF / 162LF OF BLOCK WALLS AT WEST, NORTH & EAST P/L
Type: WALL/FENCE (WEB) Subtype: CITY STANDARD/PRE- Status: FINALED
APPROVED
Applied: 12/20/2021 ECON
Approved: 1/25/2022 JFU
Issued: 1/28/2022 JFU
Finaled: 7/24/2023 JAN
Expired:
Parcel No: 774115005 Site Address: 53620 AVENIDA OBREGON LA QUINTA,CA 92253
Subdivision: SANTA CARMELITA AT VALE LA QUINTA Block: 188 Lot: 5
UNIT 19
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $4,500.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: HAFIF / 162LF OF 5' GARDEN GARDEN WALL AT WEST, NORTH, AND EAST PROPERTY LINES [CITY STANDARD SPECIFICATIONS]
PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE FROM OUTSIDE THE
PROPERTY. FOOTINGS AND CMU MUST BE LOCATED WITHIN PROPERTY LINES. 2019 CALIFORNIA BUILDING CODES.
REVISION 1- SCOPE REVISED TO CONSTRUCT COMBINATION RETAINING/GARDEN WALLS AT NORTH AND EAST PROPERTY LINES
(ANGLEUS S-1.6 SPECIFICATIONS). 16" RETAINING AT NORTH P/L, 24" RETAINING AT EAST (REAR) P/L, BOTH W/ 5' GARDEN WALLS
ON TOP OF THE RETAINING PORTION.
Process Summary
542
,36
li 3
Applied to Approved
Approved to Issued
Issued to Finaled
a. ADDITIONAL SITES
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
E-MAIL
AARON HICKSON
7/24/2023
7/24/2023
We received a phone call from the homeowner of the
above address. Concerning this wall permit. This permit was
not finaled. You will need to recall for final if the corrections
have been made.
E-MAIL
JAKE FUSON
1/20/2022
1/20/2022
EMAILED APPLICANT TO DISCUSS 1ST REVIEW COMMENTS.
E-MAIL
JAKE FUSON
1/25/2022
1/25/2022
NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND
PERMIT IS READY TO ISSUE.
E-MAIL
JAKE FUSON
2/1/2022
2/1/2022
NOTIFIED APPLICANT THAT REVISION 1 PLANS ARE
APPROVED AND FEE IS READY FOR ISSUANCE.
Printed: Monday, July 24, 2023 5:30:43 PM
1 of 9
CRI f'SYSTEMS
NOTE
Permit Details
City of La Quinta
SIJIFREDO FERNANDEZ
5/12/2023
5/12/2023
SPOKE TO CONTRACTOR OVER THE COUNTER. THE
APPLICANT I5 GOING TO USE A CLEAR COAT TO PROVIDE A
FINISH. WITH VINES TO BE USED AS A BUFFER.
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
KEVIN FARMER CONSTRUCTION
53460 AVENIDA
MADERO
LA QUINTA
CA
92253
(760)469-7057
TWOXBACK@AOL.COM
CONTRACTOR
KEVIN FARMER CONSTRUCTION
53460 AVENIDA
MADERO
LA QUINTA
CA
92253
(760)469-7057
TWOXBACK@AOL.COM
OWNER
HAFIF, RUSTON
TWOXBACK@AOL.COM
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
HOURLY CHARGE CITY
BUILDING STAFF
101-0000-42600
0.25
$43.75
$43.75
12/1/22
WEB13738
763131534
CREDIT
678677
ECON
HOURLY CHARGE CITY
BUILDING STAFF
101-0000-42600
0.75
$125.25
$125.25
2/1/22
WEB10573
635150279
79
CREDIT
678677
ECON
Total Paid for BLDG CITY STAFF - PER HOUR: $169.00 $169.00
WALL/FENCE EA
ADDITIONAL 50LF
101-0000-42404
0
$33.34
$33.34
1/26/22
WEB10504
635016983
57
CREDIT
678677
ECON
WALL/FENCE FIRST
100LF
101-0000-42404
0
$55.58
$55.58
1/26/22
WEB10504
635016983
57
CREDIT
678677
ECON
WALL/FENCE FIRST
100LF PC
101-0000-42600
0
$69.47
$69.47
1/26/22
WEB10504
635016983
57
CREDIT
678677
ECON
Total Paid for BLOCK WALL 2021: $158.39 $158.39
Printed: Monday, July 24, 2023 5:30:43 PM
2 of 9
CRWSYSTE S
Permit Details PERMIT NUMBER
City of La Quinta BWFE2021-0358
__A
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
B5A5 5B1473 FEE
101-0000-20306
0
$1.00
$1.00
1/26/22
WEB10504
6350 983
57
CREDIT
678677
ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00
BSA:
RECORDS
MANAGEMENT FEE
101-0000-42416
0
$11.00
$11.00
1/26/22
WEB10504
635016983
57
CREDIT
678677
ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
0
$5.00
$5.00
1/26/22
WEB10504
635016983
57
CREDIT
678677
ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
TOTALS: $344.39 $344.39
INSPECTIONS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
FOOTINGS
JFU
1/31/2022
1/31/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
1/28/2022 4:32 PM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
Printed: Monday, July 24, 2023 5:30:43 PM
3 of 9
CRWSYSTE S
Permit Details
City of La Quinta
FOOTINGS
JFU
1/31/2022
1/31/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
REAR P/L FOOTING EXCAVATION
INCOMPLETE, BUT UPON REVIEW OF THE
EXISTING AND PROPOSED PAD ELEVATIONS
A STANDARD GARDEN WALL WILL NOT BE
ABLE TO BE USED TO GRADE DIFFERENTIALS
EXCEEDING 6". REVISE SCOPE OF PERMIT TO
CONSTRUCT THESE WALLS AS
COMBINATION RETAINING/GARDEN WALLS
AND RECALL INSPECTION WHEN FOOTING
CONSTRUCTION IS COMPLETE.
FOOTINGS
JAN
2/2/2022
2/2/2022
APPROVED
eTRAKiT Inspection
Request
2/1/2022 4:15 PM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
BOND BEAM
DCL
2/8/2022
2/8/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
2/7/2022 3:39 PM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
- ONE NUMBER FOUR AT FIRST COURSE OF
RETAINING MISSING PER ANGELUS DETAIL.
RECALL BOND BEAM WHEN READY.
Printed: Monday, July 24, 2023 5:30:43 PM
4 of 9
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BWFE2021-035. 8. low
FOOTINGS
DCL
2/9/2022
2/9/2022
PARTIALLY
APPROVED
eTRAKiT Inspection
Request
2/8/2022 11:51 AM KEVIN FARMER
CONSTRUCTION
re inspect with engineer approval
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
- ALTERNATE HORIZONTAL REINFORCEMENT
APPROVED PER FOR APPROVAL. SEE
ATTACHMENTS.- CALL IN FRONT YARD AND
SIDE YARD RETURN WALL FOOTINGS WHEN
READY.
BOND BEAM
JAN
2/15/2022
2/15/2022
PARTIALLY
APPROVED
eTRAKiT Inspection
Request
2/12/2022 7:32 AM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
NORTH AND EAST PL WALLS TOP OUT BOND,
REFERENCE TO ATTACHMENTS
UNDERGROUND PLBG
JAN
3/31/2022
3/31/2022
CANCELED
eTRAKiT Inspection
Request
3/29/2022 5:09 PM KEVIN FARMER
CONSTRUCTION
re inspect, possibly wednesday???
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
Inspection scheduled by mistake
Printed: Monday, July 24, 2023 5:30:43 PM
5 of 9
CRWSYSTE S
Permit Details
City of La Quinta
PERMIT NUMBER
BWFE2021-0358
FOOTINGS
JFU
12/2/2022
12/2/2022
DISAPPROVE
D
INSPECTION SCHEDULED FOR FRONT YARD
WALLS.
CORRECTIONS:
NO PORTION OF THE FOOTING MAY BE
CONSTRUCTED WITHIN THE RIGHT OF WAY
(12' FROM FACE OF CURB). WHEN THE
FOOTING IS ADJUSTED TO THE CORRECT
LOCATION IT WILL NOT HAVE THE REQUIRED
29" WIDTH FOR A 5' HIGH WALL PER
APPROVED DETAILING.
FOOTINGS
BBL
12/5/2022
12/5/2022
APPROVED
Remaining portions of front footings are
approved.
BOND BEAM
BBL
12/9/2022
12/9/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
12/8/2022 1:25 PM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
Bond beam exceeds 32 inches maximum
spacing. Correct is required.Additionally
bond beam block required at top course
with steel.Vertical steel is missing in the
cells.
BOND BEAM
BBL
12/12/2022
12/12/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
12/9/2022 3:20 PM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
Printed: Monday, July 24, 2023 5:30:43 PM
6 of 9
CRWSYSTEMS
Permit Details
City of La Quinta
BOND BEAM
BBL
12/12/2022
12/12/2022
DISAPPROVE
D
eTRAKiT Inspection
Re quest
q
The block wall exceeds 5 feet from bottom
of footing to top of wall, remove blocks
greater than 5 feet from top of footing.lt
does appear that an additional 3'6" of wall
was placed at North front facing wall
without inspection. It does appear that the
East West facing 15' wall without inspection
and approval. Contact Bob bland 760-777-
7002 to discuss.
BOND BEAM
BBL
12/14/2022
12/14/2022
APPROVED
eTRAKiT Inspection
Request
12/13/2022 3:07 PM KEVIN FARMER
CONSTRUCTION
re inspect
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
Corrections have been completed top of
bond is approved.
FINAL**
JAN
5/9/2023
7/24/2023
APPROVED
eTRAKiT Inspection
Request
5/8/2023 11:08 AM KEVIN FARMER
CONSTRUCTION
Contact Name: KEVIN FARMER
CONSTRUCTION
Site Address: 53620 AVENIDA OBREGON
Phone: 7604697057
e-Mail: TWOXBACK@AOL.COM
Precision block shall be painted to match
dwelling or stucco
APPROVAL OBTAIN FROM PLANING
DEPARTMENT (SIJI FERNANDEZ)
PARENT PROJECTS
Printed: Monday, July 24, 2023 5:30:43 PM
7 of 9
CRWSYSTEMS
Permit Details AIL PERMIT NUMBER
City of La Quints BWFE2021-0358
REVIEWS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
1ST BLDG NS
ETRAKIT (1 DAY)
JAKE FUSON
12/20/2021
12/21/2021
1/20/2022
REVISIONS REQUIRED
SITE PLAN SHOWS 30" RETAINING AT THE NORTH
P/L, HOWEVER THE DETAIL PROVIDED CANNOT
BE USED FOR A RETAINING CONDITION. WILL
WORK WITH APPLICANT AND PROVIDE PRE -
APPROVED DETAILING FOR RETAINING AND
COMBO WALLS.
2ND BLDG NS —
ETRAKIT (1 DAY)
JAKE FUSON
1/24/2022
1/25/2022
1/25/2022
APPROVED
1ST BLDG NS
ETRAKIT (1 DAY)
JAKE FUSON
1/31/2022
2/1/2022
2/1/2022
APPROVED
REVISION 1
REVISION 1- SCOPE REVISED TO CONSTRUCT
COMBINATION RETAINING/GARDEN WALLS AT
NORTH AND EAST PROPERTY LINES (ANGLEUS 5-
1.6 SPECIFICATIONS). 16" RETAINING AT NORTH
P/L, 24" RETAINING AT EAST (REAR) P/L, BOTH
W/ 5' GARDEN WALLS ON TOP OF THE RETAINING
PORTION.
1ST BLDG NS (1
DAY)
JULIO ANAYA
12/1/2022
12/2/2022
12/12/2022
APPROVED
REVISION 2
1ST PLANNING —
ETRAKIT (1 DAY)
SIJIFREDO
FERNANDEZ
7/24/2023
7/25/2023
7/24/2023
READY FOR APPROVAL
CONTRACTOR STATED THAT THEY HAVE
SEALED/FINISHED WALL WITH CLEARCOAT
SEALANT.
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
12/1/2022
ARMANDO MAGALLON
REVISION 2 - SITE PLAN
3495_001.pdf
0
DOC
12/20/2021
Etrakit Contractor
1ST SUBMITTAL SITE
PLAN
hafif site plan for city
permit.pdf
1
DOC
12/13/2022
Etrakit Contractor
REVISION 2 - 1ST
SUBMITTAL SITE PLAN
obregon wall rev 2.pdf
1
Printed: Monday, July 24, 2023 5:30:43 PM
8 of 9
CRWSYSTEMS
Permit Details
City of La Quinta
PERMIT NUMBER
BWFE2021-0358
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
12/1/2022
JULIO ANAYA
REVISION 1 - SITE PLAN
(APPROVED)
BWFE2021 0358-
REVISION 1 - SITE PLAN
(APPROVED).pdf
1
DOC
1/25/2022
JAKE FUSON
SITE PLAN (APPROVED)
BWFE2021-0358 - SITE
PLAN (APPROVED).pdf
1
DOC
2/1/2022
JAKE FUSON
REVISION 1 - SITE PLAN
(APPROVED)
BWFE2021 0358-
REVISION 1 SITE PLAN
(APPROVED).pdf
1
Printed: Monday, July 24, 2023 5:30:43 PM 9 of 9
CRWSYSTEMS
KAFCON Co,
53460 Avenida Madero
La Quinta, CA 92253
53-ao cD(gz
k . IJ(1)n
67gti 6Q-61
6/ .‘4('{
1.11
peors 2 fgz,o+1
License # B678677
760-469-7057 cell
PROPOSAL
r a e" ero
era- . h tufi l l
•ALL FOOTINGS AND WALLS MUST BE
CONSTRUCTED ENTIRELY WITHIN THE
PROPERTY AND MAY NOT CROSS
PROPERTY LINES
•GARDEN WALLS MAY NOT HAVE GRADE
DIFFERENTIALS GREATER THAN 6"
27LF OF 5' GARDEN WALLS
1
12' MINIMUM
FROM FACE OF
CURB
BWFE2021-0358
HAFIF / 162LF OF 5' GARDEN
GARDEN WALL AT WEST,
NORTH, AND EAST PROPERTY
LINES [CITY STANDARD
SPECIFICATIONS] PRECISION
CONCRETE BLOCK SHALL BE
COVERED WITH STUCCO,
PAINT, OR TEXTURED
COATING WHERE VISIBLE
FROM OUTSIDE THE
PROPERTY. FOOTINGS AND
CMU MUST BE LOCATED
WITHIN PROPERTY LINES. 2019
CALIFORNIA BUILDING CODES.
lid
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE01I25I2022 BY IF
ritigOL
6060)1 (,)1,
iL;3�es
CITY OF LA QUINTA
A
„h„
heightfrom top
of footing
Reverse
direction of
hook on every
other rebar
10"
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE01/25/2022 By ji
Required when
Adjacent to Property Line
#4 Horizonta ebar
(use bond beat )lock)
6"or8"b ck
#4 horizontal at
(use bond be
SEE TABLE "A"
FOR REBAR SIZE
AND SPACING
(locate rebar in center of cell)
(FO)TING WIDTH)
SEE TABLE "A"
(Shown at 6' Height)
Table "a"
..h„
.�W„
Vertical
reinforcement
3'
17"
#4@48"O.C.
4'
20"
#4 @ 48" O.C.
5'
23"
#4 @ 48" O.C.
6'
29"
#4 @ 24" O.C.
NOTES:
1)this design does not allow grade differentials of
more than 6" on opposing sides of the wall. This is
not a retaining wall_
2)fence heights are regulated — consult zoning
regulations before beginning construction.
3) no water course or natural drainage shall be
obstructed.
EMI
lilt=
=Ilil
Finish gn
ontinuous
(2)
" max. o.c.
n block)
SEE TABLE "B"
FOR REBAR SIZE
AND SPACING
(locate rebar in center of cell)
e
I) - #4 rebar
#4 rebar
tinuous
All footings ac cent to
slopes to be at ast5'to
daylightasshol below.
BOTTOM
OF
FOOTING
4) yr out only the ells containing rebar This wall
is not designed for all cells to be grouted_
5)all rebar to be astm spec A615, grade 40 minimum
6)all rebarlapsplicestobe 24" minimum.
7) all masonry unitsto be astm C-90grade N.
8)1 ebar to be centered in masonry cells
"SEE PAGE 2 FOR ADDI IIONAL INFORMATION"
DISCLAIMER:
Alternate designs may be possible
when provided with an engineered
analysis. Use of this standard design
is at the user's risk and carries no
implied or inferred guarantee against
failure or defects.
„h„
heightfrom top
of footing
IIIIf. .=1111=1u1
I
1111E
=1111
10"
2'
=IiIL1
"w„
NG
)
WIDTH)
SEE TABLE "B"
(Shown at 5' Height)
Table "b"
Vertical
reinforcement
3'
19"
#4 @ 48" O.C.
4'
22"
#4 @ 48" O.C.
fi0.
29"
#4 @ 48" D.C.
6'
34"
#4 @ 24" O.C.
^h�..�..,r*h •�� Q•'ilr+ina Department tr
When a permit is required, the following
inspections are required:
1) FOOTING; Excavation trench clean with
steel in place and supported 3" above and
away from the surrounding earth/dirt.
2) REBAR/PRE-GROUT; Bond beam rebar and
vertical rebar in place - inspection prior to
placing grout.
3) FINAL; After grout is placed - prior to any
decorative cap placement.
western I-tivei slde Guar ity Guile Ur riful n rlty Nr uyr an l
40idea,
(A1 IFDRNiA ---
((60) fff-/125
City of La Uuinta
Building Department
Freestanding Block Wall
78-495 Calle Tampico, La Quints, CA 92260
I-AX(/so) ((f-1011
11,1 5/2U14
Uealan d,ia Uevrlu,n nc nt
I'ACit'1 01- 2
REBAR PLACEMENT
ILLUSTRATION
—0.- (TYPICAL)
All rebar splices
24" min. overlap
FOOTING OPTION A
DESIGN PARAMETERS:
ACTIVE SOIL PRESSURE (PSF) = 30
PASSIVE SOIL BEARING (PSF) =150
COEFFICIENT OF FRICTION = 0.25
ALLOWABLE SOIL BEARING (PSF) =1500
WIND = 80 MPH, EXPOSURE C
SEISMIC:
Na=1.3, Nv=1.6, Z=0.4, SOIL PROFILE=Sd
CITY OF LA QUINTA
BUILDING DIVISION
REVIEWED FOR
CODE
COMPLIANCE
DATE01/25/2022 BY F
44 II14si
N'k.,,,, FOOTING OPTION B
—0- (TYPICAL)
only cells and bond beam
courses with rebar to be
grouted
(do not solid grout entire wall - use
grout stop mesh as appropriate)
-0- (TYPICAL)
All rebar shall have a
minimum of3"concrete
cover at footings
Western Riverside County Code Uniformity Program
�Q
CAUFORNIA
(760) 777-7125
City of La Quinta
Buildin Department
Freestanding BlockWall
78-495 Calle Tampico, La Quinta, CA92260
FAX (760) 777-7011
1 1 /13/2014
Design and Development
PAGE2OF2