BSPN2017-0026 b-compressedCERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-20 Duct Leakage Test — Completely New or Replacement Duct System (Page 1 of 2) Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 Enter the Duct System Name or Identification/Tag: HOUSE: SYSTEM 1 Enter the Duct System Location or Area Served: WHOLE HOUE Note: Submit one Installation Certificate for each duct system that must demonstrate compliance in the dwelling. This certificate is required for compliance for completely new duct systems installed in new dwelling construction, and also for completely new or replacement duct systems in existing dwellings. For existing dwellings, a completely new or replacement duct system can also include existing parts of the original duct system (e.g., register boots, air handler, coil, plenums, etc.) if those parts are accessible and they can be sealed. Duct Leakage Diagnostic Test — completely new or replacement duct system Enter a value for the Allowed Leakage (CFM) for the duct system leakage verification. The value entered must be the Verified Low Leakage Ducts in Conditioned Space criteria or one of the three calculated leakage rates described below. Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Compliance Credit. If compliance credit for verified low leakage ducts in conditioned space is shown in the special features section of the CF-1R, the leakage to outside test method must be used to verify duct leakage (refer to RA3.1.4.3.4), and 25 CFM must be entered for Allowed Leakage. Allowed Leakage (CFM) Allowed leakage calculation — (select one calculation method from this section). Use 6% (leakage factor = 0.06) for calculations. When utilizing Low Leakage Air Handler (LLAH) credit, the allowed duct leakage may be specified by the CF-1R to be less than 6%, in which case the user -specified leakage rate must be used in the calculations below. For example, if the user -specified leakage (specified as a percentage of fan airflow) is reported on the CF-1R as 3%, then use a leakage factor of 0.03 in the calculations below. 0 Cooling system method: Nominal capacity of condenser in Tons 4.0 x 400 x leakage factor = 96 (CFM) 96 ❑ Heating system method: 21.7 x Output Capacity in Thousands of Btu/hr x leakage factor = (CFM) ❑ Measured airflow method (RA3.3): Enter measured fan flow in CFM here x leakage factor = (CFM) Enter value for Actual leakage (CFM) in the right column, from measurement using applicable duct leakage pressurization test procedure from Reference Residential Appendix RA3.1(CFM @ 25 Pa). List Actual Leakage from duct leakage test (CFM) Actual Leakage (CFM) 73 Pass if Actual Leakage is less than Allowed Leakage 0 Pass 0 Fail For complete replacement of duct systems only, if the 6 percent leakage rate criteria cannot be met, a smoke test should be performed to verify that the excess leakage is coming only from a pre-existing furnace cabinet (air handler cabinet), and not from other accessible portions of the duct system. A HERS rater must verify the installation (No sampling allowed). List Actual Leakage from smoke test(CFM) Pass if all accessible leaks (except for existing air handler) are sealed using smoke 0 Pass 0 Fail Registration Number: 413-N0012978B-M2000005A-M20A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:25 AM HERS Provider: CHEERS August 2009 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-20 Duct Leakage Test — Completely New or Replacement Duct System (Page 2 of 2) Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 D Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct leakage testing. D All supply and return register boots must be sealed to the drywall El New duct installations cannot utilize building cavities as plenums or platform returns in lieu of ducts. 0 Mastic and draw bands must be used in combination with Cloth backed, rubber adhesive duct tape to seal leaks at duct connections. DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. • I am the certified HERS rater who performed the verification services identified and reported on this certificate (responsible rater). • The installed feature, material, component, or manufactured device requiring HERS verification that is identified on this certificate (the installation) complies with the applicable requirements in Reference Residential Appendices RA2 and RA3 and the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the local enforcement agency. • The information reported on applicable sections of the Installation Certificate(s) (CF-6R), signed and submitted by the person(s) responsible for the installation conforms to the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the enforcement agency. Builder or Installer information as shown on the Installation Certificate (CF-6R) Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) True Air Mechanical, Inc. Responsible Person's Name: Sergio Samuyo CSLB License: C20 HVAC (956171) HERS Provider Data Registry Information Sample Group # (if applicable): RNC13336 D tested/verified dwelling 0 not-tested/verified dwelling in a HERS sample group HERS Rater Information HERS Rater Company Name: Energy Inspectors Corporation Responsible Rater's Name Daniel Lawrence Responsible Rater's Signature Daniel Lawrence Responsible Rater's Certification Number w/ this HERS Provider: RCN10124 Date Signed: 11/18/2014 10:25 AM Registration Number: 413-N0012978B-M2000005A-M20A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:25 AM HERS Provider: CHEERS August 2009 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-20 Duct Leakage Test — Completely New or Replacement Duct System (Page 1 of 2) Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 Enter the Duct System Name or Identification/Tag: HOUSE: SYSTEM 1 Enter the Duct System Location or Area Served: WHOLE HOUE Note: Submit one Installation Certificate for each duct system that must demonstrate compliance in the dwelling. This certificate is required for compliance for completely new duct systems installed in new dwelling construction, and also for completely new or replacement duct systems in existing dwellings. For existing dwellings, a completely new or replacement duct system can also include existing parts of the original duct system (e.g., register boots, air handler, coil, plenums, etc.) if those parts are accessible and they can be sealed. Duct Leakage Diagnostic Test — completely new or replacement duct system Enter a value for the Allowed Leakage (CFM) for the duct system leakage verification. The value entered must be the Verified Low Leakage Ducts in Conditioned Space criteria or one of the three calculated leakage rates described below. Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Compliance Credit. If compliance credit for verified low leakage ducts in conditioned space is shown in the special features section of the CF-1R, the leakage to outside test method must be used to verify duct leakage (refer to RA3.1.4.3.4), and 25 CFM must be entered for Allowed Leakage. Allowed Leakage (CFM) Allowed leakage calculation — (select one calculation method from this section). Use 6% (leakage factor = 0.06) for calculations. When utilizing Low Leakage Air Handler (LLAH) credit, the allowed duct leakage may be specified by the CF-1R to be less than 6%, in which case the user -specified leakage rate must be used in the calculations below. For example, if the user -specified leakage (specified as a percentage of fan airflow) is reported on the CF-1R as 3%, then use a leakage factor of 0.03 in the calculations below. 0 Cooling system method: Nominal capacity of condenser in Tons 5.0 x 400 x leakage factor = 120 (CFM) 120 ❑ Heating system method: 21.7 x Output Capacity in Thousands of Btu/hr x leakage factor = (CFM) ❑ Measured airflow method (RA3.3): Enter measured fan flow in CFM here x leakage factor = (CFM) Enter value for Actual leakage (CFM) in the right column, from measurement using applicable duct leakage pressurization test procedure from Reference Residential Appendix RA3.1(CFM @ 25 Pa). List Actual Leakage from duct leakage test (CFM) Actual Leakage (CFM) 98 Pass if Actual Leakage is less than Allowed Leakage 0 Pass 0 Fail For complete replacement of duct systems only, if the 6 percent leakage rate criteria cannot be met, a smoke test should be performed to verify that the excess leakage is coming only from a pre-existing furnace cabinet (air handler cabinet), and not from other accessible portions of the duct system. A HERS rater must verify the installation (No sampling allowed). List Actual Leakage from smoke test(CFM) Pass if all accessible leaks (except for existing air handler) are sealed using smoke 0 Pass 0 Fail Registration Number: 413-N0012978B-M2000005A-M20A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:25 AM HERS Provider: CHEERS August 2009 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-20 Duct Leakage Test — Completely New or Replacement Duct System (Page 2 of 2) Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 D Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct leakage testing. D All supply and return register boots must be sealed to the drywall El New duct installations cannot utilize building cavities as plenums or platform returns in lieu of ducts. 0 Mastic and draw bands must be used in combination with Cloth backed, rubber adhesive duct tape to seal leaks at duct connections. DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. • I am the certified HERS rater who performed the verification services identified and reported on this certificate (responsible rater). • The installed feature, material, component, or manufactured device requiring HERS verification that is identified on this certificate (the installation) complies with the applicable requirements in Reference Residential Appendices RA2 and RA3 and the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the local enforcement agency. • The information reported on applicable sections of the Installation Certificate(s) (CF-6R), signed and submitted by the person(s) responsible for the installation conforms to the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the enforcement agency. Builder or Installer information as shown on the Installation Certificate (CF-6R) Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) True Air Mechanical, Inc. Responsible Person's Name: Sergio Samuyo CSLB License: C20 HVAC (956171) HERS Provider Data Registry Information Sample Group # (if applicable): RNC13336 D tested/verified dwelling 0 not-tested/verified dwelling in a HERS sample group HERS Rater Information HERS Rater Company Name: Energy Inspectors Corporation Responsible Rater's Name Daniel Lawrence Responsible Rater's Signature Daniel Lawrence Responsible Rater's Certification Number w/ this HERS Provider: RCN10124 Date Signed: 11/18/2014 10:25 AM Registration Number: 413-N0012978B-M2000005A-M20A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:25 AM HERS Provider: CHEERS August 2009 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-20 Duct Leakage Test — Completely New or Replacement Duct System (Page 1 of 2) Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 Enter the Duct System Name or Identification/Tag: HOUSE: SYSTEM 1 Enter the Duct System Location or Area Served: WHOLE HOUSE Note: Submit one Installation Certificate for each duct system that must demonstrate compliance in the dwelling. This certificate is required for compliance for completely new duct systems installed in new dwelling construction, and also for completely new or replacement duct systems in existing dwellings. For existing dwellings, a completely new or replacement duct system can also include existing parts of the original duct system (e.g., register boots, air handler, coil, plenums, etc.) if those parts are accessible and they can be sealed. Duct Leakage Diagnostic Test — completely new or replacement duct system Enter a value for the Allowed Leakage (CFM) for the duct system leakage verification. The value entered must be the Verified Low Leakage Ducts in Conditioned Space criteria or one of the three calculated leakage rates described below. Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Compliance Credit. If compliance credit for verified low leakage ducts in conditioned space is shown in the special features section of the CF-1R, the leakage to outside test method must be used to verify duct leakage (refer to RA3.1.4.3.4), and 25 CFM must be entered for Allowed Leakage. Allowed Leakage (CFM) Allowed leakage calculation — (select one calculation method from this section). Use 6% (leakage factor = 0.06) for calculations. When utilizing Low Leakage Air Handler (LLAH) credit, the allowed duct leakage may be specified by the CF-1R to be less than 6%, in which case the user -specified leakage rate must be used in the calculations below. For example, if the user -specified leakage (specified as a percentage of fan airflow) is reported on the CF-1R as 3%, then use a leakage factor of 0.03 in the calculations below. 0 Cooling system method: Nominal capacity of condenser in Tons 2.5 x 400 x leakage factor = 60 (CFM) 60 ❑ Heating system method: 21.7 x Output Capacity in Thousands of Btu/hr x leakage factor = (CFM) ❑ Measured airflow method (RA3.3): Enter measured fan flow in CFM here x leakage factor = (CFM) Enter value for Actual leakage (CFM) in the right column, from measurement using applicable duct leakage pressurization test procedure from Reference Residential Appendix RA3.1(CFM @ 25 Pa). List Actual Leakage from duct leakage test (CFM) Actual Leakage (CFM) 50 Pass if Actual Leakage is less than Allowed Leakage 0 Pass 0 Fail For complete replacement of duct systems only, if the 6 percent leakage rate criteria cannot be met, a smoke test should be performed to verify that the excess leakage is coming only from a pre-existing furnace cabinet (air handler cabinet), and not from other accessible portions of the duct system. A HERS rater must verify the installation (No sampling allowed). List Actual Leakage from smoke test(CFM) Pass if all accessible leaks (except for existing air handler) are sealed using smoke 0 Pass 0 Fail Registration Number: 413-N0012978B-M2000005A-M20A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:25 AM HERS Provider: CHEERS August 2009 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-20 Duct Leakage Test — Completely New or Replacement Duct System (Page 2 of 2) Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 D Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct leakage testing. D All supply and return register boots must be sealed to the drywall El New duct installations cannot utilize building cavities as plenums or platform returns in lieu of ducts. 0 Mastic and draw bands must be used in combination with Cloth backed, rubber adhesive duct tape to seal leaks at duct connections. DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. • I am the certified HERS rater who performed the verification services identified and reported on this certificate (responsible rater). • The installed feature, material, component, or manufactured device requiring HERS verification that is identified on this certificate (the installation) complies with the applicable requirements in Reference Residential Appendices RA2 and RA3 and the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the local enforcement agency. • The information reported on applicable sections of the Installation Certificate(s) (CF-6R), signed and submitted by the person(s) responsible for the installation conforms to the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the enforcement agency. Builder or Installer information as shown on the Installation Certificate (CF-6R) Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) True Air Mechanical, Inc. Responsible Person's Name: Sergio Samuyo CSLB License: C20 HVAC (956171) HERS Provider Data Registry Information Sample Group # (if applicable): RNC13336 D tested/verified dwelling 0 not-tested/verified dwelling in a HERS sample group HERS Rater Information HERS Rater Company Name: Energy Inspectors Corporation Responsible Rater's Name Daniel Lawrence Responsible Rater's Signature Daniel Lawrence Responsible Rater's Certification Number w/ this HERS Provider: RCN10124 Date Signed: 11/18/2014 10:25 AM Registration Number: 413-N0012978B-M2000005A-M20A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:25 AM HERS Provider: CHEERS August 2009 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING CF-4R-MECH-23 Verification of Hi h EER E s ui ment (Pale 1 of 1 Site Address: 81-275 Storm Cat Ct Enforcement Agency: City of La Quinta Permit Number: 13-1634 Verification of High EER Equipment Procedures for verification of High EER Equipment are described in Reference Residential Appendix RA3.4. For dwelling units with multiple systems, the procedures must be applied to each system separately. As many as 4 systems in the dwelling can be documented for compliance usin this form. Attach an additional forms) for any additional systems in the dwelling as applicable. 1 System Name or Identification/Tag HOUSE: SYSTEM 1 HOUSE: SYSTEM 1 HOUSE: SYSTEM 1 2 System Location or Area Served WHOLE HOUE WHOLE HOUE WHOLE HOUSE 3 Certified EER Rating of the installed equipment (Btu/Watt-hr) 11.50 11.50 11.50 4 Make and Model Number of the installed Outdoor Unit AIRE FLO 4ac13148p-7a AIRE FLO 4ac13160p-7a AIRE FLO 4ac13130p-7a 5 Make and Model Number of the installed Inside Coil ALLSTYLE ASFM48-24A34GVS ALLSTYLE ASFM60-24A36GVS ALLSTYLE ASLT30-20A28GVS 6 Make and Model Number of the installed Furnace or Air Handler. AIRE FLO 80AF1U110P2OCL AIRE FLO 80AF1UH110P2OCL AIRE FLO 80AF1UH070P12AL 7 Minimum Equipment EER required for compliance as reported on the CF-1R 11.50 11.50 11.50 0 When a high EER system specification includes a time delay relay, the installation of the time delay relay must be verified for compliance credit. Refer to Reference Residential Appendix RA3.4.3 for the Time Delay Relay Verification Procedure. El When installation of specific matched equipment is necessary to achieve a high EER, installation of the specific equipment must be verified for compliance credit. Refer to Reference Residential Appendix RA3.4.3 for the Matched Equipment Verification Procedure. 8 If the Certified EER Rating in row 3 is equal or greater than the required minimum EER in row 7, the unit complies. If the unit complies enter Pass Pass Pass Pass DECLARATION STATEMENT • • I certify under penalty of perjury, under the laws of the State of California, the information provided on this form is true and correct. • I am the certified HERS rater who performed the verification services identified and reported on this certificate (responsible rater). • The installed feature, material, component, or manufactured device requiring HERS verification that is identified on this certificate (the installation) complies with the applicable requirements in Reference Residential Appendices RA2 and RA3 and the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the local enforcement agency. • The information reported on applicable sections of the Installation Certificate(s) (CF-6R), signed and submitted by the person(s) responsible for the installation conforms to the requirements specified on the Certificate(s) of Compliance (CF-1R) approved by the enforcement agency. Builder or Installer information as shown on the Installation Certificate (CF-6R) Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) True Air Mechanical, Inc. Responsible Person's Name: Sergio Samuyo CSLB License: C20 HVAC (956171) HERS Provider Data Registry Information Sample Group # (if applicable): RNC13336 D tested/verified dwelling 0 not-tested/verified dwelling in a HERS sample group HERS Rater Information HERS Rater Company Name: Energy Inspectors Corporation Responsible Rater's Name Daniel Lawrence Responsible Rater's Signature Daniel Lawrence Responsible Rater's Certification Number w/ this HERS Provider: RCN10124 Date Signed: 11/18/2014 10:26 AM Registration Number: 413-N0012978B-M2300006A-M23A 2008 Residential Compliance Forms Registration Date/Time: 11/18/2014 10:26 AM HERS Provider: CHEERS August 2009