BSOL2022-0136 Building PlansO
O
TRANSITION BOX (TYP.)
(N) LOAD CENTER
(INSIDE GARAGE)
UTILITY AC DISCONNECT
SWITCH (OUTSIDE GARAGE
WITHIN SIGHT FROM THE MAIN
SERVICE PANEL)
C
(E) SERVICE POINT AND
UTILITY METERING
D&E
TO ELECTRIC
UTILITY GRID
NOTES & LEGENDS
LOT & ARRAY INFORMATION
ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR
INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR
BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT.
PLAN
4
SYSTEM SIZE
ELEVATION
B
STORY TYPE
ROOF TYPE
S-TILE
ORIENTATION
ROOF PITCH
4:12
LOCATION
(3') WIDE ACCESS PATH (TILE ROOF) / (4') WIDE ACCESS PATH (FLAT ROOF)
ARRAY SQ. FT.
322 SQ. FT.
LAYOUT/SCHEME
6.30 KW
1-STORY
150° & 240°
FRONT & LEFT
4
DRIVEWAY
ROOF ACCESS POINT
MODULE QTY.
18
MODULE TYPE
SPR-X21-350-BLK-E-AC
LOT NUMBER
45
MOUNTING &
ATTACHMENT
INSET - INVISIMOUNT
PHASE NUMBER
1
CONDUCTOR / CONDUIT SCHEDULE
TAG
DESCRIPTION &
CONDUCTOR TYPE
CONDUCTOR
SIZE(AWG)
NUMBER
OF
CONDUCTORS
CONDUIT/ CABLE
TYPE
CONDUIT SIZE
(WHEN NEEDED)
❑A
SUNPOWER PROVIDED AC MODULES EXTENSION
CABLE, LISTED AS AN ASSEMBLY
#12
2
WITH EGC
#6
1
TYPE -ER, PER
BRANCH CIRCUIT
CU-NM-B
#10
2
EGC BARE CU
#10
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
CU-NM-B
#10
3
EGC BARE CU
#10
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
❑D
CU-NM-B
#14
3
EGC BARE CU
#14
1
NM CABLE OR EQ
INSTALLED IN WALL CAVITY
❑E
AWG TWISTED PAIR
#22
3
NMFC
INSTALLED IN WALL
CAVITY
1/2"
FRONT OF HOUSE (FOH)
ROOF ACCESS POINT
BSOL2022-0136
CI TY OF LA QU N TA
BULONGOVI9ON
REVI EVED FOR
CUE COPRLI AV CE
J.ANAYA D E: 0412812022
6.3kW SOLAR ARRAY - (18) 350W SUNPOWER
SPR-X21-350-BLK-E-AC PANELS W/
INTEGRATED MICROINVERTERS + 100A PV LOAD
CENTER [360SF] REFERENCE BCPR2021-0030
FOR APPROVED MASTER PLANS. 2019 CALIFORNIA
BUILDING CODES.
4
SYSTEMS
Z
0
0
0
U
0
v
o,
0
0
0
S
0
(510) 540-0550
Ln
o,
0
co
Lu
w
0
J
U
TRACT/PARCEL #: 31249
Z
0
W
Ir
BEAZER HOMES - SOUTHERN CALIFORNIA
SOLAR INDIVIDUAL PLOT PLAN PACKAGE
8■■■■■■■■■■■■■■
B11111■■■■■■■■■
0
0
11111111111111
111111■■■■■■■■■
COMMUNITY ID
PROJECT NO.
DATE DRAWN
DRAWN BY
DATE CHECKED
CHECKED BY
C002295
RP-214753
FOR
1
SHEET
PVA-1
PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES
CAUTION
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS
LOCATED AS SHOWN:
18 MODULES/MICRO-INVERTER
SPR-X21-350-BLK-E-AC (240)
INSET (S-TILE)
PEGASUS
4
PHOTOVOLTAIC -
ARRAY ON ROOF
LOAD CENTER
PHOTOVOLTAIC
AC DISCONNECT
MAIN SERVICE
PANEL
T 1
F —+—
i
F —+—
i
F —+—
i
F —+—
i
L_-L_J
DRIVEWAY
58-181 CORAL VIEW WAY
CI TY OF LA QU N TA
BULDNGOVISON
REVI EYED FOR
MICE COPRLI AV CE
J.ANAYi- o E: 04/28/2022
SIGNAGE NOTES
1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT.
2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHIN MINIMUM 3/8" LETTER HEIGHT, WHITE ON RED BACKGROUND.
3. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE.
SYSTEMS
z
0
0
a
0
O
u
co
rn
0
O
_
u
0
(510) 540-0550
TRACT/PARCEL #:31249
0
W
0
w o
a
BEAZER HOMES - SOUTHERN CALIFORNIA
8■■■■■■■■■■■■■■
B11111■■■■■■■■■
0
0
11111111111111
111111■■■■■■■■■
COMMUNITY ID
PROJECT NO.
DATE DRAWN
DRAWN BY
DATE CHECKED
C002295
RP-214753
CHECKED BY
FOR
SHEET
PVA-2