BSOL2022-0136 Building PlansO O TRANSITION BOX (TYP.) (N) LOAD CENTER (INSIDE GARAGE) UTILITY AC DISCONNECT SWITCH (OUTSIDE GARAGE WITHIN SIGHT FROM THE MAIN SERVICE PANEL) C (E) SERVICE POINT AND UTILITY METERING D&E TO ELECTRIC UTILITY GRID NOTES & LEGENDS LOT & ARRAY INFORMATION ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. FIRE ACCESS POINTS SHALL NOT BE LOCATED OVER DOORS AND WINDOWS OR BE OTHERWISE OBSTRUCTED BY ATTIC VENT, PLUMBING VENT, MECHANICAL VENT. PLAN 4 SYSTEM SIZE ELEVATION B STORY TYPE ROOF TYPE S-TILE ORIENTATION ROOF PITCH 4:12 LOCATION (3') WIDE ACCESS PATH (TILE ROOF) / (4') WIDE ACCESS PATH (FLAT ROOF) ARRAY SQ. FT. 322 SQ. FT. LAYOUT/SCHEME 6.30 KW 1-STORY 150° & 240° FRONT & LEFT 4 DRIVEWAY ROOF ACCESS POINT MODULE QTY. 18 MODULE TYPE SPR-X21-350-BLK-E-AC LOT NUMBER 45 MOUNTING & ATTACHMENT INSET - INVISIMOUNT PHASE NUMBER 1 CONDUCTOR / CONDUIT SCHEDULE TAG DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE(AWG) NUMBER OF CONDUCTORS CONDUIT/ CABLE TYPE CONDUIT SIZE (WHEN NEEDED) ❑A SUNPOWER PROVIDED AC MODULES EXTENSION CABLE, LISTED AS AN ASSEMBLY #12 2 WITH EGC #6 1 TYPE -ER, PER BRANCH CIRCUIT CU-NM-B #10 2 EGC BARE CU #10 1 NM CABLE OR EQ INSTALLED IN WALL CAVITY CU-NM-B #10 3 EGC BARE CU #10 1 NM CABLE OR EQ INSTALLED IN WALL CAVITY ❑D CU-NM-B #14 3 EGC BARE CU #14 1 NM CABLE OR EQ INSTALLED IN WALL CAVITY ❑E AWG TWISTED PAIR #22 3 NMFC INSTALLED IN WALL CAVITY 1/2" FRONT OF HOUSE (FOH) ROOF ACCESS POINT BSOL2022-0136 CI TY OF LA QU N TA BULONGOVI9ON REVI EVED FOR CUE COPRLI AV CE J.ANAYA D E: 0412812022 6.3kW SOLAR ARRAY - (18) 350W SUNPOWER SPR-X21-350-BLK-E-AC PANELS W/ INTEGRATED MICROINVERTERS + 100A PV LOAD CENTER [360SF] REFERENCE BCPR2021-0030 FOR APPROVED MASTER PLANS. 2019 CALIFORNIA BUILDING CODES. 4 SYSTEMS Z 0 0 0 U 0 v o, 0 0 0 S 0 (510) 540-0550 Ln o, 0 co Lu w 0 J U TRACT/PARCEL #: 31249 Z 0 W Ir BEAZER HOMES - SOUTHERN CALIFORNIA SOLAR INDIVIDUAL PLOT PLAN PACKAGE 8■■■■■■■■■■■■■■ B11111■■■■■■■■■ 0 0 11111111111111 111111■■■■■■■■■ COMMUNITY ID PROJECT NO. DATE DRAWN DRAWN BY DATE CHECKED CHECKED BY C002295 RP-214753 FOR 1 SHEET PVA-1 PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 18 MODULES/MICRO-INVERTER SPR-X21-350-BLK-E-AC (240) INSET (S-TILE) PEGASUS 4 PHOTOVOLTAIC - ARRAY ON ROOF LOAD CENTER PHOTOVOLTAIC AC DISCONNECT MAIN SERVICE PANEL T 1 F —+— i F —+— i F —+— i F —+— i L_-L_J DRIVEWAY 58-181 CORAL VIEW WAY CI TY OF LA QU N TA BULDNGOVISON REVI EYED FOR MICE COPRLI AV CE J.ANAYi- o E: 04/28/2022 SIGNAGE NOTES 1. MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2. ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHIN MINIMUM 3/8" LETTER HEIGHT, WHITE ON RED BACKGROUND. 3. DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. SYSTEMS z 0 0 a 0 O u co rn 0 O _ u 0 (510) 540-0550 TRACT/PARCEL #:31249 0 W 0 w o a BEAZER HOMES - SOUTHERN CALIFORNIA 8■■■■■■■■■■■■■■ B11111■■■■■■■■■ 0 0 11111111111111 111111■■■■■■■■■ COMMUNITY ID PROJECT NO. DATE DRAWN DRAWN BY DATE CHECKED C002295 RP-214753 CHECKED BY FOR SHEET PVA-2