Loading...
BSOL2021-0197 aFORMAT: WHITE LETTERING ON A RED BACKGROUND.(2) MINIMUM 3/8" LETTER HEIGHT.(3)ALL LETTERS SHALL BE CAPILAZIDED.(4)ARIAL OR SIMILAR FONT, NON -BOLD. MATERIAL: REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARDS FOR WEATHER RATING) DURABLE ADHESIVE MATERIAL MEETS THIS REQUIREMENT. CAUTION THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR PANELS ON ROOF LEGEND: SERVICE PANEL OO AC DISCONNECT 3 SUBPANEL 4; INVERTER PV MODULES POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE RATED AC OUTPUT CURRENT 64.0 A NOM OPERATING AC VOLTAGE 240 V To be installed at the existing panel board next to the backfed PV breaker WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE OVERCURRENT DEVICE To be installed at inverter grounded systems WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULTS IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Conduits and Raceways label every 10' CAUTION: SOLAR CIRCUIT To be installed at Solar AC disconnect and any Toad centers. SOLAR AC DISCONNECT To be installed at the PV Subpanel. WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR To be installed on the face of service meter. CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED To be installed at inverter MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC -TO -DC CONVERTER (IF INSTALLED) 480 V 20.0 A 15 A ONE ON EACH INVERTER WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN I SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY The title "SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN" shall utilize capitalized characters with a minimum height of 9.5 mm (3/8 in.) in black on yellow background, and the remaining characters shall be capitalized with a minimum height of 4.8 mm (3/16 in.)in black on white background(690.56(c)) To be installed outside or within 3' of the service panel board To be installed next to the rapid shutdown disconnect RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM Hegge Electrical Contractor Inc. Contractor License Type C10 Lic # 748171 83-852 Ave. 45th Indio, CA. 92201 Jim Hegge Tel. 760-775-4855 jim@heggeelectrical.com Contractor: Jim Hegge Signature Revisions Date City Revisions 11-11-21 Equipment Location 10-17-22 M rn o CO U To c U E (6 J > , c.) cjIm � co c o .0 ti ° O O _c 0 co 1 M Lf) l Legal Description: APN # 779440017 Scale: NTS Date: 10-13-21 Drawn by: Solar Permit Design Services Cell. 760-409-6289 solarpermitds@gmait com Project No. 21-788 Sheet No. 004