BSOL2021-0197 aFORMAT: WHITE LETTERING ON A RED BACKGROUND.(2) MINIMUM 3/8" LETTER HEIGHT.(3)ALL LETTERS SHALL BE CAPILAZIDED.(4)ARIAL OR SIMILAR FONT,
NON -BOLD. MATERIAL: REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARDS FOR WEATHER RATING)
DURABLE ADHESIVE MATERIAL MEETS THIS REQUIREMENT.
CAUTION
THE SUN IS SUPPLYING ELECTRICITY TO THIS BUILDING THROUGH SOLAR
PANELS ON ROOF
LEGEND:
SERVICE PANEL OO AC DISCONNECT
3 SUBPANEL 4; INVERTER PV MODULES
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS OVERCURRENT DEVICE
RATED AC OUTPUT CURRENT 64.0 A
NOM OPERATING AC VOLTAGE 240 V
To be installed at the existing panel board
next to the backfed PV breaker
WARNING
INVERTER OUTPUT CONNECTION DO NOT
RELOCATE OVERCURRENT DEVICE
To be installed at inverter grounded systems
WARNING
ELECTRIC SHOCK HAZARD
IF GROUND FAULTS IS INDICATED
NORMALLY GROUNDED CONDUCTORS
MAY BE UNGROUNDED AND ENERGIZED
Conduits and Raceways
label every 10'
CAUTION: SOLAR CIRCUIT
To be installed at Solar AC disconnect
and any Toad centers.
SOLAR AC DISCONNECT
To be installed at the PV Subpanel.
WARNING:
THIS EQUIPMENT FED BY MULTIPLE SOURCES
TOTAL RATING OF ALL OVERCURRENT DEVICES
EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE
SHALL NOT EXCEED AMPACITY OF BUSBAR
To be installed on the face of service meter.
CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED
To be installed at inverter
MAXIMUM VOLTAGE
MAXIMUM CIRCUIT CURRENT
MAX RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER OR
DC -TO -DC CONVERTER (IF INSTALLED)
480 V
20.0 A
15 A
ONE ON EACH INVERTER
WARNING:
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE
LINE AND THE LOAD SIDES MAY
BE ENERGIZED IN THE OPEN
POSITION
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID SHUTDOWN I
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
The title "SOLAR PV SYSTEM IS
EQUIPPED WITH RAPID SHUTDOWN"
shall utilize capitalized characters with a
minimum height of 9.5 mm (3/8 in.) in black
on yellow background, and the remaining
characters shall be capitalized with a
minimum height of 4.8 mm (3/16 in.)in black
on white background(690.56(c))
To be installed outside or within 3' of the service panel board
To be installed next to the rapid
shutdown disconnect
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
Hegge Electrical
Contractor Inc.
Contractor
License Type C10
Lic # 748171
83-852 Ave. 45th
Indio, CA. 92201
Jim Hegge
Tel. 760-775-4855
jim@heggeelectrical.com
Contractor:
Jim Hegge
Signature
Revisions
Date
City Revisions
11-11-21
Equipment Location
10-17-22
M
rn
o
CO U
To
c U
E
(6 J
> ,
c.) cjIm
� co
c
o .0 ti °
O O
_c
0
co
1
M
Lf)
l
Legal Description:
APN # 779440017
Scale: NTS
Date: 10-13-21
Drawn by:
Solar Permit Design Services
Cell. 760-409-6289
solarpermitds@gmait com
Project No.
21-788
Sheet No.
004