BSOL2021-0197-compressedPermit Details PERMIT NUMBER
City of La Quints BSOL2021-0197
111111i Ark. M
Description: EAST OF MADISON/ 16.1kW PV SYSTEM - (46) PANELS/(2) INV/SUB
Type: SOLAR (WEB) Subtype: Status: FINALED
Applied: 10/18/2021 ECON
Approved: 2/8/2022 JFU
Issued: 2/8/2022 DCL
Finaled: 10/21/2022 JAN
Expired:
Parcel No: 767700026 Site Address: 53845 HUMBOLDT BLVD LA QUINTA,CA 92253
Subdivision: TR 33076-2 Block: Lot: 74
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Valuation: $58,000.00 Occupancy Type: Construction Type:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
Details: 16.1kW SOLAR ARRAY - (46) 350W LONG! SOLAR LR4-60HPB-350M PANELS W/ (2) SMA SUNNYBOY SB7.7-1SP-US-41 INVERTERS +
100A PV LOAD CENTER [920SF] 2019 CALIFORNIA BUILDING CODES.
Process Summary
255
113
Applied to Approved
Approved to Issued
Issued to Finaled
ADDITIONAL SITES
— CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
E-MAIL
JAKE FUSON
11/2/2021
11/2/2021
NOTIFIED APPLICANT OF 1ST REVIEW COMMENTS, SENT
CORRECTION LIST VIA EMAIL.
E-MAIL
JAKE FUSON
2/8/2022
2/8/2022
NOTIFIED APPLICANT THAT PLANS ARE APPROVED AND
PERMIT IS READY TO ISSUE.
LOCATION TRANSFER
JAKE FUSON
11/2/2021
11/2/2021
LINKED TO ADDRESS 53845 HUMBOLDT BLVD FROM 53805
HUMBOLDT.
RESUBMITTAL
JAKE FUSON
1/11/2022
1/11/2022
CONDITIONS
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY I STATE ZIP PHONE FAX EMAIL
APPLICANT
HEGGE ELECTRICAL CONTRACTORS
INC
83852 AVE 45
INDIO
CA
92201
sherryl@heggeelectrica
I.com
Printed: Sunday, August 13, 2023 10:39:20 PM
1 of 4
CRWSYSTEMS
All
Permit Details
City of La Quinta
PERMIT NUMBER
BSOL2021-0197
CONTACTS
NAME TYPE
NAME
ADDRESS1
CITY I STATE ZIP PHONE I FAX EMAIL
CONTRACTOR
OWNER
HEGGE ELECTRICAL CONTRACTORS
INC
EAST OF MADISON
83852 AVE 45
P 0 BOX 1482
INDIO
LA QUINTA
CA
CA
92201
0
sherryl@heggeelectrica
I.com
FINANCIAL
INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
BY
BSAS SB1473 FEE
101-0000-20306
0
$3.00
$3.00
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for BUILDING STANDARDS ADMINISTRATION
BSA: $3.00 $3.00
PV SYSTEM GREATER
THAN 10KW
101-0000-42403
0
$41.68
$41.68
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
PV SYSTEM GREATER
THAN 10KW PC
101-0000-42600
0
$41.68
$41.68
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
PV SYSTEM MISC
EQUIPMENT
101-0000-42403
0
$27.79
$27.79
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
PV SYSTEM MISC
EQUIPMENT PC
101-0000-42600
0
$27.79
$27.79
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for ELECTRICAL 2021: $138.94 $138.94
PERMIT ISSUANCE
101-0000-42404
0
$105.60
$105.60
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for PERMIT ISSUANCE: $105.60 $105.60
RECORDS
MANAGEMENT FEE
101-0000-42416
0
$11.00
$11.00
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for RECORDS MANAGEMENT FEE: $11.00 $11.00
TECHNOLOGY
ENHANCEMENT FEE
502-0000-43611
0
$5.00
$5.00
2/8/22
WEB10657
635277509
67
CREDIT
HEGGE ELECTRICAL
CONTRACTORS INC
ECON
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 $5.00
Printed: Sunday, August 13, 2023 10:39:20 PM
2 of 4
CRWSYSTEMS
Permit Details
City of La Quinta
PERMIT NUMBER
BSOL2021-0197
INSPECTION
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
ROUGH ELEC
DCL
2/24/2022
2/24/2022
DISAPPROVE
D
- PROVIDE SOLAR PV POWER SOURCE
LABELING AT ATTIC CONDUIT.
ROUGH ELEC
DCL
10/14/2022
10/14/2022
APPROVED
SOLAR FINAL**
DCL
10/14/2022
10/14/2022
DISAPPROVE
D
eTRAKiT Inspection
Request
10/13/2022 9:42 AM HEGGE ELECTRICAL
CONTRACTORS INC
Contact Name: HEGGE ELECTRICAL
CONTRACTORS INC
Site Address: 53845 HUMBOLDT BLVD
Phone: 7607754855
e-Mail: Jim.Hegge@heggeelectrical.com
- REVISE PLANS AND MAIN SERVICE
ELECTRICAL PANEL PLACARD TO
ACCURATELY REFLECT THE LOCATIONS OF
MAIN SERVICE AND SOLAR PV EQUIPMENT. -
NUMBER 6 AWG WIRE USED FROM LOAD
CENTER TO INVERTER. PLEASE CLARIFY
INCREASE IN CONDUCTOR SIZE.- RATED AC
OUTPUT CURRENT SIGNAGE MISSING AT
MAIN SERVICE BACK FED BREAKER. REFER
TO PLAN SHEET 004.- PROVIDE LADDER FOR
ROOF ACCESS TO VERIFY PANEL WATTAGE,
CONDUCTOR TYPE/SIZE, AND BONDING.
ADDITIONAL CORRECTIONS MAY APPLY.
SOLAR FINAL**
JAN
10/21/2022
10/21/2022
APPROVED
PARENT PROJECTS
REVIEWS
Printed: Sunday, August 13, 2023 10:39:20 PM
3 of 4
CRWSYSTEMS
Permit Details
imilmit City of La Quints
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
1ST BLDG NS
ETRAKIT (1 DAY)
JAKE FUSON
10/18/2021
10/19/2021
11/2/2021
REVISIONS REQUIRED
SEE 1ST REVIEW CORRECTION LIST.
2ND BLDG NS —
ETRAKIT (1 WK)
JAKE FUSON
1/11/2022
1/18/2022
2/8/2022
APPROVED
BOND INFORMATION
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
10/18/2021
Etrakit Contractor
1ST SUBMITTAL SOLAR
PLAN
Lot 74 Ps-V10-14.pdf
1
DOC
1/11/2022
Etrakit Contractor
2ND SUBMITTAL SOLAR
PLAN
Lot 74 Ps -REV 11-23.pdf
1
DOC
1/11/2022
Etrakit Contractor
2ND SUBMITTAL
RESPONSES
RESPOPNSES- BSOL2021
-0197 - 1ST REVIEW
CORRECTION LIST.pdf
1
DOC
1/20/2022
Etrakit Contractor
REVISED SFD ENERGY
REPORT (FOR
REFERENCE ONLY)
BRE52021 0164-
REVISION 1 ENERGY
REPORT
(APPROVED).pdf
1
DOC
10/17/2022
Etrakit Contractor
003-SIGNAGE
DIAGRAM -LOT 74.pdf
1
DOC
11/2/2021
JAKE FUSON
1ST REVIEW
CORRECTION LIST
BSOL2021-0197 - 1ST
REVIEW CORRECTION
LIST.pdf
1
DOC
2/8/2022
JAKE FUSON
SOLAR PLAN
(APPROVED)
BSOL2021-0197 - SOLAR
PLAN (APPROVED).pdf
1
Printed: Sunday, August 13, 2023 10:39:20 PM
4of4
CRWSYSTEMS