BRES2022-0157 Building Plans-compressed4' 8"X 5'
.47 .24
6' X 5'
.47 .24
4' X 3'
.47 .24
8' X 8'
.48 .25
10' X 8'
.48 .25
10' X 3'6"
.37 .24
BRES2022-0157
CI TY OF LA QU N TA
BULDNGDVISON
REVI EVED FOR
COCE COWL! AV CE
BY A. o : 0313112022
(10) RETROFIT FENESTRATION
SURFACE CHANGEOUTS. THIS
PERMIT DOES NOT INCLUDE
FRAMING ALTERATIONS. 2019
CALIFORNIA BUILDING CODES.
23.5 SQ FT
ENRTY DOOR
6' X 5'
.47 .24
4'X1'6"
.47 .24
6' X 5'
.47 .24
NOTES:
-Window replacement in bedrooms shall
meet tho requirements of 2019 CRC
Chapter R310. "Emergency Escape and
Rescue Openings".
-All window/door fenestration labels shall
remain attached until after final
inspection.
-All new windows/doors shall comply with
the Safety Glazing for Hazardous
Locations per the 2019 California
Residential Code, Chapter R308.
Comply with 2019 CRC
Chapter R310.
54-125 OAK HILL PGA PALMER
NTS
.4.1 .44
Design and Title 24, Inc.
74-818 VELIE WAY STE 8
PALM DESERT, CA 92260
(760) 200-4780 OFFICE
(760) 702-5406 CELL
www.scottdesignandtitle24.com
Project Name and Address
Residence
54-125 OAK HILL
PGA PALMER
LA QU I NTA CA 92253
Sheet
title 24
Date
8-12-21
T24
Scale
NONE
CERTIFICATE OF COMPLIANCE
Project Name: 54-125 Oak Hill PGA
Calculation Description: Title 24 Analysis
Calcofatkkn Datedme: 2021-0S 12T15:10:23.07:OO
Input File Name: 54-125 Oak HIII-PGA-IW Glass-21_ri#td19x
CF1R-PRF-01E
(Page 1 of 8)
GENERAL INFORMATION
01
Project Name.
S4.1250.31. Hill PGA
02
Run Title
Title 24 Anatysls
03
Project Location
54.125 oak Hill PGA
04
City
LaQUinta
OS
standards version
2019
06
Zip rode
9.1253
07
Software Version
fnergypro 82
08
Climate Zone
15
09
front Orientation (deg/ Cardinal)
45
10
Building Type
Single family
11
NurnberofDwelling units
1
12
Project Scope
AdditionAlteration
13
Number of Bedrooms
3
14
Addition Cond. Floor Area (ft1)
0
15
Number of stories
1
16
Existing Cond. Floor Area (ft).
1573
i7
Fenestration Average U-factor
0.43
18
Total Cond. Floor Area (ftl)
1673
19
Glazing Percentage [91j
20.93%
20
ADU Bedroom Count
n/a
21
ADU Conditioned Wont Area
n/a
22
Is Natural Gas Available?'
Yes
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
Building does not require field testing or HERS verification
03
This building incorporates one or more Special Features shown below
ENERGY USE SUMMARY
Energy Use IkTDV/ftl-yr]
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
space Cooling
IA4'.'entilation
Water Heating
self Utilization/Flei[ibility Credit
Compliance Energy Total
3.93
256.14
0
18.113
n/a
278.3
6.06
251.78
0
18.16
0
276.02
-2.0S
4-56
0
0
0
2.48
-52.3
1.3
0
nia
0.9
Registration Number.
CA Building Energy Efficiency Standards - 2019 Residential Compliance
CERTIFICATE OF COMPLIANCE
Project Name: 54-125 Oak Hill PGA
Calculation Descri ption: Title 24 Analysis
Registration laate;Time
Report Ver5i0n- 2019.1.300
Schema '.rersion. rev 26200401
HERS Provider
Report Generated. 2021-08-12 13.5o:39
Calculation Date/Tune: 2021-08-12T15:10.23(17:00
Input File Name: 54-125 Oak Hill-PGA-1W Glass-21.rihd19x
CF1R-PRF-01E
(Page 4 of 8)
FENESTRATION / GLAZING
GI
02
03
04
05
06
07
08
09
10
II
12
13
IA
15
16
Name
type
surface
Orientation
Azimuth
width
lit)
Height
Ill
MOIL-
Area
( j
U-factor
U•factor
Source
SHGC
SHGC
Source
Exterior
shading
status
verified
Existing
Condition
window a
Window
5 wall
180
1
64
[Lag
NFRC
0-25
NFRC
Bug Screen
Altered
Na
window 9
Window
5 wall
180
1
80
0.48
NFRC
0.25
NFRC
Bug screen
Altered
No
Window 10
window
5 :'rail
130
1
35
0.48
NFRC
0.25
NFRC
lug screen
Altered
NO
SLAB PUDORs
91
02
03
04
05
06
07
03
09
10
Name
Zone
Area (ft2l
Perimeter (ft)
Edge Insul.
R-value and
Depth
Edge insul.
R•value and
Depth
Carpeted Fraction
Heated
Status
Verified Existing
Condition
51ab-on-Grade
Residence
1673
162
none
0
605E
No
Existing
No
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
ult erior / Exterior
Continuous
R-value
U-factor
Assembly Layers
3-13 'Nall
Exterior Walls
wood Framed Wal i
284 6 16 in. o. c.
R-13
None f Node
0.101
Inside Finish: Gypsum Board
Cavity f Frame: R-13 / 254
Exterior Finish: 3 Coat Stucco
R-13 wan
Interior Walls
ch'ocd Framed wall
2x1.a 15 in 0 C
R•13
None I Node
0.092
Inside Finish: Gypsum Board
Cavity f Frame: R•13 / 21r4
Other side Finish: Gypsum Board
Attic RoofResidence
Attic Roofs
wood Framed2x4
Ceiling
.: 2141 1 O. C
R-0
None / None
o.6Si
Roofing: Light Roof (Asphalt Shingle}
Root Deck: wood
5 iding/sfiearthingldecking
cavity / Frame: no intul. / 2x4
Registration Number:
CA Building Energy Efficiency standards - 2019 Residential compliance
Registration Dater rime:
Report Version: 2019.1.300
Schema version: rev 202013901
HERS Provider:
Report Generated. 2021-08-12 is. 10:39
C E RTiFICATE OF COMPLIANCE
Project Name: 54-:25 Oak Hill PGA
Calculation Description: Tale 24 Analysis
Calculation Date/Time:2021-08-12T15:10:23-07:00
Input File Name: 54-125 Oak Hill -PGA -NY Glass-21._ritd19x
CF1R-PRF-01E
[Page 2 of 8]
REQUIRED SPECIAL FEATURES
The following are features that must be Installed as condition for meeting the modeled energy performance for this computer analysis.
ventral pars Ilel piping
HERS FEATURE 5UMMARY
The following Is a summary of the features that must he field -'verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional
detail is provided in the buildngtabi s below_ Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry
Building -level verifications'.
• -- None --
Cooling System Verifications:
• -- Ndne --
Heating System verifications:
• -- None --
HVAC Distribution System Verifications:
• -- None -
Domestic Hot Water System Venfrcations:
• -- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of dwelling
Units
Number of Bedrooms
Number of zones
Number of ventilation
cooling systems
Number of Water
Heating systems
34.125 Dak Hill PG..
1673
1
3
1
0
ZONE INFORMATION
61
02
r
05
04
OS
06
07
lone Name
Zone Type
HVAC System Name
Zone Floor Area Ift2j
Avg. Ceiing Height
Water Heating System 1
Water Heating System 2
Residence
Conditioned
HVACI
1673
9
DH'r.' SpS I
f3./;.
Registration Number:
CA 5uiiding Energy tFFiciency standards - 2019 Residential compliance
C E RTiFI CATE OF COMPLIANCE
Project Name: 54-125 Oak Hill PGA
Calculation Description: TRIe 24 Analysis
Registration Date/Time:
Report Version: 2019.1.300
Schema Version: rev 20200901
HERS Pros; ider:
Report Generated. 2021-08-12 15'10:59
Calculation Datefrime; 2021-08-12T15:10 23.07:00
Input File Name: 54-125 Oak Hill-PGA-1W Glass-21_01d19x
CF1R-PRF-01E
(Page 5 of 8)
0PAOIJE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
68
Construction Name
surface Type
construction Type
Framing
Total Cavity
Rica lue
Interior if Exterior
Continuous
R-value
U-factor
Assembly Layers
Oefaul: 1978 to present
Ceilings (below
attic)
wood Framed
ceiling
2e4 igg 14 tn. O_ C.
R-11
None d None
0.083
Over Ceilingraists. R-1.9 insul.
Cavlry / Frame: R-9.1 I zed
Inside Finish: Gypsum Board
BUILDING ENVELOPE - HERS VERIFICATION
01
02
03
04
Quality insulation Installation itl1il
High R-value Spray Foam Insulation
Building Envelope Air Leakage
t:FM50
Not Required
Not Required
Not Required
n/a
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
04
(19
10
Name
system Type
DlStributionType
water Heater Name iv)
501arfleating
System
cam pact
Distribution
HERS Verificatlen
status
vetiGed
Existing
Cand fti on
Existing
water
Heating
system
0f1W Sys 1
Domestic Hat
L4'ater IDHwI
Parallel Piping
DEW H1111
n/a
None
Ala
'a
Existing
Nr•
WATER HEATERS
01
02
03
04
05
05
07
08
09
10
11
12
13
14
Name
Heating
Element
Type
Tank Type
e of
Units
Tank
Vol,
[gal]
Energy
Factor or
Efficiency
Input Rating
or Pilot
Tank
insulation
R-value
(Tot/Ert}
Standby
Loss or
Recovery EHFlow
istHr.
Rating or
Rate
NEEA (teat Pump
Brand or Model
Tank Location
or Ambient
Condition
status
Verified
Existing
Condition
HW
}f e 1
Gas
Small Storage
1
50
0.55-EF
kBtishr
0
76
nfa
n'a
n/a
Existing
No
Registration Number:
CA Building Energy Efficiency Standards - 2019 Residential compliance
C E RTiFI CATE OF COMPLIANCE
Project Name: 54-:..25 Oak Hill PGA
Calculation Descrption: Tale 24 Analysis
Registration Dater rime:
Report Version- 2019.1.300
Schema version: rev 26200901
HERS Provider:
Report Generated. 2021-08-12 15:10:59
Calculation Dateffirne; 2021-08-12T15:10 23.07:00
Input File Name: 54-125 Dak Hill-PGA-IW Glass-21-tt7]d19x
CF1R-PRF-01E
(Page 7 of 8)
IMVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
66
07
08
05
10
11
12
13
14
15
16
Dila Ins R-value
Duct Location
surface .Area
Name
Type
Design
Type
supply
Return
Supply
Return
Supply
Return
Bypass
Duct
Dud
Leakage
HERS
verification
5t_etllt
verified
Existing
condition
Existing
Distribution
system
New Ducts
40 ft
Air
Distributi
on
System 1
unconditioned
attic
Non-
Verified
R-6
R-6
Attic
Wit- c
nra
nfa
No
Bypass
Duct
existing
{not
Specked}
Air
Dig [ibUti
on System
1-Ners-
dist
Existing
No
n:a
tiVAC FAN SYSTEMS -HERS VERIFICATION
01
02
03
Name
Verified Fan Watt D raw
Required Fan Efficacy (Watts/C F M i
HVAC Fan 1-hers-fan
Not Pe gUired
a
Registration Number:
CA 8uiiding Energy Efficiency standards - 2019 Residential compliance
Registration DatetTime:
Report version: 2019.1.300
Schema version: rev 20200901
HERS Provider:
Report Generated• 2021-08-12 is. 10:39
CERTIFICATE OF COMPLIANCE
Project Name: 54-125 Oak Hill PGA
Calculation Description: Tele 24 Analysis
Calculation Date/Time: 2021-08-12T15:10.23.07:00
Input File Name: 54-125 Dak Hill-PGA-IW Glass-21_rilTdlgx
CF1R-P11F-41E
(Page 9 of F4
OPAQUE SURFACES
01
02
93
04
05
06
07
08
09
16
11
Name
Zone
Construction
Azimuth
Orientation
z
Gross Area (ft I
window and
Door Area (ft2j
Tilt (deg)
Wall Exceptions
Status
verified Existing
condition
N Wall
Residence
Ft-13 Wall
0
n/a
300
64
90
none
Existing
No
NC Wall
Residence
R-13 wall
45
Front
300
12
90
none
Existing
No
E wall
Residence
R-13 Wall
90
n/a
500
72
90
none
Existing
N ❑
5 Wall
Residence
R-13 Wall
i80
n/a
320
203
90
none
Existing
No
W wail
Residence
R-13Wall
270
n/a
640
0
90
none
Existing
No
Interior Surface
Residence
R-13Wall1
n/a
n/a
3E9
0
nia
Existing
No
ROW
Residence
Defaul' 147ft to
present
n/a
n/a
1673
5-9
c/a
Existing
Na
ATTIC
01
02
03
04
05
06
07
08
09
10
Name
Construction
Type
Roof RISC
{x Iri 12j
Roof
Reflectance
ROOF
Emltta ace
Radiant
barrier
Cool Roof
Status
verified Existing
condition
Attic Residence
Attic RoofResidence
ventilated
3
0.1
0.35
No
No
Existing
No
FENESTRATION / GLAZING
01
02
03
I14
OS
06
07
06
04
10
11
12
13
14
15
16
Name
Type
Surface
Orientation
Azimuth
Width
UT)
Height
InI
Mult.
Area
( `
U-[actor
u-factor
source
SHGC
SHGC
SOYrce
Exterior
Shading
Status
verified
Existing
Condition
window
window
N wail
0
1
64
0.48
NFRC
0.23
NFRC
Bug Screen
Altered
No
Window 2
Window
NE wall
Front
45
1
12
0.48
NFRC
0.25
NFRC
Bug Screen
Altered
No
Window 3
Window
E'Wall
90
1
30
0.48
NFRC
0.25
NFRC
Bug Screen
Altered
No
WlndoW 4
Window
E 'Nall
90
1
6
0.46
NFRC
0-2-5
NFRC
Bug screen
Altered
No
Window 5
Window
E '.Wall
90
1
6
0.48
NFRC
0.25
NFRC
Bug screen
Altered
No
Window 6
Window
E :Wall
90
1
30
0.48
NFRC
0.25
NFRC
Bug Screen
Altered
No
Window 7
Window
5 Wall
180
1
24
0.48
NFRC
0.25
NFRC
Bug Screen
Altered
No
Registration Number:
CA Building Energy Efficiency standards - 2019 Residential compliance
CERTIFICATE OF COMPLIANCE
Project Name: 54-125 Oak Hill PGA
Calculation Description: Tele 24 Analysis
Registration Da e/Tirne
Report Version: 2019.1.300
Schema version: rev 20200901
HERS Provider:
Report Generated 2021-08-12 15'10:39
Ca l c ul stian Date/Time: 2021-08-12T15:10.23.07:00
Input File Name: 54-125 Oak Hill-PGA-IW Glass-21_rilTdlgx
CF1R-PRF-01E
(Page 6 of 8)
WATER HEATING - HERS VERIFICATION
01
02
63
04
05
06
07
08
Name
Pipe Insulation
Parallel Piping
Comport Distribution
compact Distribution
Type
Recirculation Control
centralDHW
Distribution
shower Drain water
Heat Rec9Yery
DHW Sys 1- 1/1
Not Required
Hot Required
Not Required
None
Nut Required
Nat Required
Not Required
5 PACE C ON DIITON ING SYSTEMS
01
02
01
04
05
06
07
08
09
10
11
Name
9pt.rnTyp.
Heating Unit
Name
cooling Unit
Name
Fan Name
Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
cooling
Equipment
taunt
I•i'JAC1
Heating and cooling system
other
Heating
Component
1
Cooling
Component
1
N4'AC Fan 1
Air
Distribution
system 1
ilia
Existing
No
1
1
HVAC • HEATING UNITTYPES
01
02
03
04
Name
system Type
Number of units
Heating Efficiency
Heating Component 1
central gas furnace
1
AFUE-110
HVAC • COOLING UNIT TYPES
01
02
03
04
05
06
07
08
Name
system Type
Number of Units
Efficiency EER/CEER
Efficiency SEER
Zonally controlled
Mulit-speed
Compressor
HERS verification
Cooling Component 1
Central split AC
1
10
-2
Nat lanai
single speed
COO ling Component
1-hers-cool
Registration Number:
CA Building Energy Effciency standards - 2019 Residential compliance
CE RTi FI CATE OF COMPLIANCE
Project Name: 54-125 Oak Hill PGA
Calculation Description: Title 24 Analysis
Registration Detect ime:
Report Version: 2019.1.390
Schema version: rev 26200901
HERS Provider:
Report Generated 2021-08-12 15'10:39
Calculation Dateflirne: 2021-08-12115:10.23.07:00
Input File Name: 54-125 Dark Hill PGA IW Glass-21.r1lbd19x
CF1R-PRF-01E
(Page 8 of 8)
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. l certify that this Certificate of Compliance documentation is accurate and complete
Documennton Author Name:
Jon d. Scott
Doeumesmtian Author 5.ignanue:
Jon d. Scott 8-13-21
Cam part':
Scott Design and Ttle 24, Inc,
signature Dane:
8/13/2021
Address:
74-818 Velie Way STE 8
CEAr HERS C-..iC .t:...i Identilicition LIE applicable):
City/StaoefZip:
Palm Desert, CA 92260
Phone:
760-204-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the Following under pen uhty of perjury, under the laws of she S;aoe or California:
1. lam eligible .rider Diuis:n 3 of the $2si nese and Professions Code to acre rat responsibility for the build ng design identified on this Certificate of Compfrpnce.
2, I certify that the energy feature; an l per5v rance speci(;catians identified arr'his Ce.tiF Cate of Compliance wrdw*n to Aire •equirements of Tsle 24, Pars 1 and Part 6 of the California Code of Regina[ ans-
3. The building design features or _system design features ide nt -,fed an this Cer =leAte of Compliance are consistent with the information provided on other applieeble corn p!ianee documents. worksheets,
caikiliations. plans and rpeeir.catiarr submrRet to the enfarrernent a6eretf For approval With this building permit 2ppficatien.
Resporuaaie Designer Name.
IW Mirror and Glass
Responsible Des gnrr Signal are .
Cornpsr.y,
Indian Wells Mirror and Glass
Date Signed.
Address_
St Charles Place
l dose:
Cit /Stateflip:
Palm Desert, CA 92260
Phone:
(760) 779-0671
Registration Number:
CA Building Energy Efficiency Standards - 2019 Residential compliance
Registration Irate rime:
Report VerSion: 2019.1.300
schema version: rey 20200901
HERS Provider
Report Generated.2021-08-12 15:10:59
BRES2022-0157
CI TY OF LA QU N TA
BULEI NGOVISCN
REVI EYED FOR
COCE COWL! AV CE
BY: A. ME: 03/31/2022
Design and Title 24, Inc.
74-818 VELIE WAY STE 8
PALM DESERT, CA 92260
(760) 200-4780 OFFICE
(760) 702-5406 CELL
www.scottdesignandtitle24.com
Project Name and Address
Residence
54-125 OAK HILL
PGA PALMER
LA QU I NTA CA 92253
Sheet
title 24
Date
8-12-21
T24.1
Scale
NONE