05-4517 (SFD) Title 24TITLE 24 REPORT Title 24 Report for: Fuller Residence 57 370 Peninsula Lane La Quinta, CA 92253 Project Designer: Andrzej W. Weber Architect AIA 74 133 EI Paseo, Suite A Palm Desert, CA 92260 (760) 340-3002 Report Prepared By: CITY OF � �'DEP.AT BUILDING APPROVED FOR CONSTIR DATE�=( BY Wayne Seward, CEA R01-04-273 Bear Technologys 7774 Calle Mejor Carlsbad, CA 92009 (760) 635-2327 Job Number: 5082910 Date: 2/13/2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.0 by EnergySoft Job Number. 5082910 User Number: 5956 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary 1 2 3 11 13 14 EnergyPro 4.0 by EnergySoft Job Number: 5082910 User Number: 5956 Certificate Of Compliance: Residential (Part 1 of 4) CF -1 R Filler Residence 2/13/2006 Date Project Title 57 37_0 Peninsula I ane I a_Qtiinta Project Address Building Permit # Rear Technoloava (760) 635-2327 Documentation Author Telephone Plan Check/Date Prn C mpl��cee Method 15 Climate Zone Field Check/Date TDV EnergyUse Standard Proposed Compliance (kBtu/sf-yr Design Design Margin Space Heating 1.76 1.18 0.58 Space Cooling 56.95 54.38 2.57 Fans 8.56 8.25 0.31 Domestic Hot Water 3.34 6.29 -2.95 Pumps 0.00 0.07 -0.07 Totals 70.61 70.17 0.44 Percent better than Standard: U.ti% I BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: Single Family ❑ Addition Total Conditioned Floor Area: 7,677 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ftz Building Front Orientation: (W) 270 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 7,677 ft2 Fenestration: Average Ceiling Height: 10.1 ft Area: 1,947 ft2 Avg. U: 0.37 Number of Dwelling Units: 1.00 Ratio: 25.4% Avg. SHGC: 0.32 Number of Stories: 1 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAr System 7.R77 77 384 1 nn Slee. SleeningStat n/a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Roof Wood 4606 n 019 -R-10 R-0 n 0 n Roof Wood 1051 0.036 13-30 R-0.0 a 0 Wall Wood 664 0.074 R_19 R-0.0 0 go Wall Wand 1,314 0074 R-19 R-0.0 _90 g0 Wall Wood 640 0.074 R_19 R-0.0 180 90 Wall Wood 1,297 0.074 R_19 R-0.0 270 90 Wall Wand 1 031 0 074 R-19 R-0.0 n An Gains Condition Y / N Status JA IV Reference Location / Comments Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page:3 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Fuller Residence Project Title SHGC Hgt.. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. Date 2/13/2006 FENESTRATION SURFACES # Type Area True Cond. U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Location/ Comments _1_ Skylight Left (N) 4.0 0.370 NFR __0..29, NFRC 0 _0_ New Skylight LowP2 Tinted 1st Floor 2 3 Skylight Skylight Left Left (N) (N) 4.0 4.0 0.370 NFRC 0_29 NFRC 0 0 New Skylight Lowe2 Tinted 0.370 NFRC 0_29 NFRC 0 0 New Skylight Lowe2 Tinted 1st Floor 1st Floor 4 Skylight Left (N) 4.0 0.370 NFRC 0_29 NFRC 0 0 New Skylight Lowe2 Tinted 1st Floor 5 Skylight Left (N) 4.0 0.370 NFRC 0_29 NFRC 0 0 New Skylight Lowe2 Tinted 1st Floor 6 Window Left (N) 6.0 0.370 NFRC 0_32 NFRC 0 90 New Double Non Metal Low -E 1st Floor L Window Left (N) 33.3 0.370 NFRC 0.32 NFRC 0 90 New Double Non Metal Low -E 1st Floor 8 Window Left (N) 4.0 0.370 NFRC 0.32 NFRC 0 90 New Double Non Metal Low -E 1st Floor 3 Window Left (Nl 20.0 0.37 NFRC 0.32 NFRQ 090( New Double Non Metal Low -E 1st Floor 1Q Window Left (N) 12.5 0.370 NFRC 0.32 NFRC 0 90 New Double Non Metal Low -E 1st Floor 11 12 Aa Window Window Window Left Left Left (N) (N) (N) 12.5 0.370 NFRC 0_32 NFRC 0 90 New Double Non Metal Low -E 12.5 0.370 NFRC 0_32 NFRC 0 90 New Double Non Metal Low -E 12.5 0.3.79 NFRQ 0-32 NFRC 0 __c9Q New Double Non Metal Low -E 1st Floor list Floor 1 st Floor 14 Window Left (N) 48.0 0.370 NFRC 0_32 NFRC 0 90 New Double Non Metal Low -E 1st Floor 15 16 Window Window Left Left (N) (N) 48.0 4.0 0.370 NFRC 0_32 NFRC 0 90 New Double Non Metal Low -E 0.370 NFRC 0_32 NFRC 0 90 New Double Non Metal Low -E 1st Floor 1st Floor 17 18 Window Window Left Rear (N) (E) 4.0 6.0 0.370 NFRC 0_32 NFRC: 0 90 New Double Non Metal Low -E 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 1st Floor 19 Window Rear (E) 6.0 0.37 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt.. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 _ 4 None 1.00 _ 5 None 1.00 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 _ 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Tvoe (sf) (in.) CaD. Cond. R -Val. JA IV Reference Status , Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 580 None No Insulation 26-A1 New 1st Floor Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page:4 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Fuller Residence 2/13/2006 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGCZ True Cond. Azm. Tilt Stat. Glazing Type Location/ Comments ZQ Window Rear (E) 80.0 0.370ER._0.32 NERC 90_ q0_New Double Non Metal Low -F 1st Floor 21 Window Rear (E) 6.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E list Floor 22 Window Rear (E) 10.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E list Floor 23 Window Rear (E) 10.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 24 Window Rear (E) 10.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 25 Window Rear (E) 140.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 2& Window Rear (E) 4.0 0.370 NFRC 0..32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 27 Window Rear (E) 4.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 21 Window Rear (E) 4.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 21 Window Rear (E) 4.0 0.37 NFRC 0.32 NFRC 9090 New Double Non Metal Low -E 1 st Floor 30 Window Rear (E) 25.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 31 Window Rear (E) 25.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor Window Rear (E) 25.0 0.370 NFRC 0.32 NFRC 90_ 90 New Double Non Metal Low -E 1st Floor 33 Window Rear (E) 24.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 34 Window Rear (E) 4.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 35 Window Rear (E) 48.8 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 36 Window Rear (E) 48.0 0.370 NFRC 0_32 NFRC: 90 90 New Double Non Metal Low -E 1st Floor 37 Window Rear (E) 15.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 38 Window Rear (E) 15.0 0.370NFIRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 21 Bug Screen 0.76 _ 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 _ 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 Bug Screen 0.76 32 Bug Screen 0.76 33 Bug Screen 0.76 _ 34 Bug Screen 0.76 35 Bug Screen 0.76 36 Bug Screen 0.76 37 Bug Screen 0.76 38 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ TvDe (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Length R -Val. Insulation Location Condition JA IV Reference Status Location/ Comments Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page:5 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Fuller Residence 2/13/2006 Project Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments 3R Window Rear (E) 48.0 0.370 NFRC 032 (NFRC _90 _90_New Double Non Metal Low -E 1st Floor 40 Window Rear (E) 80.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 41 Window Rear (E) 24.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E list Floor 42 Window Rear (E) 40.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 43 Window Rear (E) 80.0 0.370 NFRC 0.32 NFRC 90 90 New Double Non Metal Low -E 1st Floor 44 Window Rear (E) 20.0 0.370 NFRC 0_32 NFRC 90 90 New Double Non Metal Low -E 1st Floor A5 Window Rear ()a 8.0 0.370 NFRC -O-a2 11FRC 90 90 New Double Non Metal Low -E list Floor 46 Window Right (S) 10.0 0.370 NFRC 0.32 NFRC 180 90 New Double Non Metal Low -E list Floor 47 Window Right (S) 36.0 0.370 INFRC 0.32 NFRC 180 90 New Double Non Metal Low -E 1st Floor -4,$ Window Right (S) 48.0 0.370 NFRC 0.32 NFRQ 180 90 New Double Non Metal Low -E list Floor 49 Window Right (S) 8.0 0.370 NFRC 0_32 NFRC 180 90 New Double Non Metal Low -E list Floor 50 Window Right (S) 144.0 0.370 NFRC 0_32 NFRC 180 90 New Double Non Metal Low -E 1st Floor J1 Window Right (S) 180.0 0.370 NFRC 0.32 NFRC 180 --Q New Double Non Metal Low -E 1st Floor 52 Window Right (S) 12.5 0.370 NFRC 0_32 NFRC 180 90 New Double Non Metal Low -E 1st Floor 53 Window Right (S) 12.5 0.370 NFRC 0_32 NFRC 180 90 New Double Non Metal Low -E list Floor 54 Window Right (S) 12.5 0.370 NFRC 0_32 NFRC 180 90 New Double Non Metal Low -E 1st Floor 55 Window Right (S) 12.5 0.370 NFRC 0_32 NFRC: 180 90 New Double Non Metal Low -E list Floor 56 Window Right (S) 25.0 0.370 NFRC 0_32 NFRC 180 90 New Double Non Metal Low -E list Floor 57 Window Right (S) 25.0 0.370! FRC0 32 NFRC 18090 New Double Non Metal Low -E list Floor 1. Indicate source either from NFRC or Table 116A, 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 39 Bug Screen 0.76 40 Bug Screen 0.76 _ 41 Bug Screen 0.76 42 Bug Screen 0.76 43 Bug Screen 0.76 44 Bug Screen 0.76 45 Bug Screen 0.76 46 Bug Screen 0.76 47 Bug Screen 0.76 48 Bug Screen 0.76 49 Bug Screen 0.76 50 Bug Screen 0.76 51 Bug Screen 0.76 52 Bug Screen 0.76 53 Bug Screen 0.76 54 Bug Screen 0.76 55 Bug Screen 0.76 56 Bug Screen 0.76 _ 57 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type L Insulation R -Val. Location JA IV Reference Condition Location/ Status Comments Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page:6 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Fuller Residence 2/13/2006 Project Title Date FENESTRATION SURFACES pe Area U -Factor' SHGCZ �$ Window Right (.S) 25.0 0 370r1EBC 032 59 Window Right (S) 4.0 0.370 NFRC 0_32 60 Window Front (W) 4.0 0.370 NFRC 0_32 61 Window Front (W) 4.0 0.370 NFRC 0.32 62 Window Front (W) 4.0 0.370 NFRC 0.32 63 Window Front (W) 4.0 0.370 NFRC 0.32 _64 Window Front (yyl 4.0 0.370 NFRC 0.32 65 Window Front (W) 10.0 0.370 NFRC 0.32 6M Window Front (W) 15.0 0.370 NFRC 0.32 _QZ Window Front (VVI�4 .0 0.37 NFRC 0.32 68 Window Front (W) 15.0 0.370 NFRC 0_32 69 Window Front (W) 10.0 0.370 NFRC 0_32 ]Q Window Front (4 4.0 0.370 NF$Q-0-32 71 Window Front (W) 8.0 0.370 NFRC 0_32 72 Window Front (W) 8.0 0.370 NFRC 0.32 73 Window Front (W) 48.0 0.370 NFRC 0_32 74 Window Front (W) 25.0 0.370 NFRC 0_32 75 Window Front (W) 6.0 0.370 NFRC 0.32 776 Window Front (W) 6 0 0.370 NFRC 0.32 True Cond. Azm. Tilt Stat. Glazi Location/ Comments NFRC 180 q.0_ New Double Nnn Metal Low -E 1st Floor NFRC 180 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1 st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC: 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor NFRC 270 90 New Double Non Metal Low -E 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 58 Bug Screen 0.76 59 Bug Screen 0.76 60 Bug Screen 0.76 61 Bug Screen 0.76 62 Bug Screen 0.76 63 Bug Screen 0.76 64 Bug Screen 0.76 65 Bug Screen 0.76 _ 66 Bug Screen 0.76 67 Bug Screen 0.76 _ 68 Bug Screen 0.76 69 Bug Screen 0.76 70 Bug Screen 0.76 71 Bug Screen 0.76 72 Bug Screen 0.76 _ 73 Bug Screen 0.76 74 Bug Screen 0.76 _ 75 Bug Screen 0.76 _ 76 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by Energysoft User Number. 5956 Job Number: 5082910 Page:7 of 14 Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R Fuller Residence 2/13/2006 Project.Title Date FENESTRATION SURFACES True Cond. Location/ # Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type Comments ]Z Window Front (yo 8.0 (1.37(1 NFRC JLU NFRC 270 q_New Double Non Metal Low -F 1st Floor 78 Window Front (W) 4.0 0.370 NFRC 0_32 NFRC 270 90 New Double Non Metal Low -E 1st Floor 79 Window Front (W) 4.0 0.370 NFRC 0_32 NFRC 270 90 New Double Non Metal Low -E 1st Floor 80 Window 'Front (W) 6.0 0.370 NFRC 0_32 NFRC 270 90 New Double Non Metal Low -E 1st Floor 81 Window Front (W) 48.0 0.370 NFRC 0.32 NFRC 270 90 New Double Non Metal Low -E 1st Floor 82 Window Front (W) 48.0 0.370 NFRC 0_32 NFRC 270 90 New Double Non Metal Low -E 1st Floor 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 77 Bug Screen 0.76 _ 78 Bug Screen 0.76 _ 79 Bug Screen 0.76 80 Bug Screen 0.76 81 Bug Screen 0.76 82 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Type Len Insulation Condition Location/ R -Val. Location JA IV Reference Status Comments Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page:8 of 14 Certificate Of ComDliance : Residential (Part 3 of 4) CF -1 R Fuller Residence 2/13/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? HVAC System Ducted Ducted Attic 6.0 New Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated' Tank Energy Standby' Tank Insul. Water Heater # in Input Cap. Condition Factor Loss R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE 1 (%) Ext. Generic 75 Gal Small Gas Recirc/rime+Temp 2 60,000 75 New 0.50 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Attached Heating & Cooling load summary is submitted as part of the calculations required by the current regulations. DO NOT USE FOR ACTUAL EATING & AC DESIGN. COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Documentation Author Name: Wayne Seward, CEA R01-04-273 Title/Firm: Andrzej W. Weber Architect AIA Title/Firm: Bear Technologys Address: 74 133 EI Paseo, Suite A Address: 7774 Calle Mejor Palm Des n CA 92260 Carlsbad, CA 92009 Telephone 760 340 3002 Telephone: (760) 635-2327 Lic. #: `A Z/ k �) _ /I �/ / 02/13/2006 (sign—atur4 / / (date) (signatui ` / , (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature/stamp) (date) Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R Fuller Residence 2/13/2006 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement aaencv determines the adeauacv of the iustification, and may refect a building or design that otherwise complies based on the idequacy of the special justification and documentation submitted. Plan I Field The HVAC System "HVAC System" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. I I� HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- ipprOVeU nCRJ PIUV1UM Ub1119 VGV OF/F/IVVCu lCJ111119 OIIV/VI VCIIIIUaLIVII IIICl11VUZI OIIY III- YC ICF WIW VII LICvl y1� I Plan I Field nstallation certificate. on CF -4R. Run Initiation Time: 02/13/06 16:22:36 Run Code: 1139876556 EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page: 10 of 14 Mandatory Measures Summary: Residential (Page 1 of 2) MFA R NOTE: Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercedes the items marked with and asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures �§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ N ❑ § 150(b): Loose fill insulation manufacturers labeled R -Value: N ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ a ❑ apply to exterior mass walls). § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑X ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: Q ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑x ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. 0 ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑X ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑X ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑X ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑K ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiftration Controls. ❑X ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ER ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑x ❑ Coefficient (SHGC), and infiltration certification. Page: 11 of 14 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ ❑X ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑X ❑ ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ 0 ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑X ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external Q ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑X ❑ ❑ indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑X ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑X ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑X ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. Q ❑ ❑ EnergyPro 4.0 by EnergySoft User Number. 5956 Job Number: 5082910 Page: 11 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) WAR NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial.applicable boxes when completed or check NIA if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ Q ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑X ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive ❑ © ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ® ❑ ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating X❑ ❑ ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ❑X ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ FAI ❑ 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the X❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. © ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑x ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑X ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ® ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria X❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ❑x ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ Q ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ ❑X ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑ OR are controlled by an occupant sensor(s) ceritfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ ❑X ❑ controlled by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑X ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑X ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.X❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more X❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number. 5082910 Page: 12 of 14 Residential Kitchen Lighting Worksheet WS -5R Fuller Residence 2/13/2006 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. High Efficacy Luminaire Type High Efficacy? Wafts Quantity Watts Other Watts 1 55w Fluorescent Circline T5 Rapid Start Yes X No 55.0 x 19 = 1.045 or g40w Fluorescent Circline T5 Elec Yes X No 80.0 x 4 = 320 or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes Nox = or Yes No x = or Total A: 1,365 B: 0 COMPLIES IF Aa B YES ® NO ❑ EnergyPro 4.0 by EnergySoft User Number: 5956 Job Number: 5082910 Page: 13 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Fuller Residence 2/13/2006 SYSTEM NAME FLOOR AREA HVAC System 7 677 FMr 1PdFFRINr: CHECKS SYSTEM 1 AAr] Number of Systems 7 Heating System Output per System 80,000 Total Output (Btuh) 560,000 Output (Btuh/sgft) 72.9 Cooling System Output per System 60,000 Total Output (Btuh) 420,000 Total Output (Tons) 35.0 Total Output (Btuh/sgft) 54.7 Total Output (sgft/Ton) 219.3 Air System CFM per System 0 Airflow (cfm) 0 Airflow (cfm/sgft) 0.00 Airflow (cfm/Ton) 0.0 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 ote: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 130,797 7,900 1 120,827 Furnance (80.0/13.0) 358,994 0 560,000 Total Adjusted System Output 358,994 0 560,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK I Aug 2 F Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 OF 70.0 OF 110.0 OF I Supply Air Ducts Outside Air 0 cfm Heating Coil 110'0 of ROOMS 70.0 of 70.0 of I :OGLING SYSTEM 11.0 / 77.6 of Outside Air 17 0 cfm 78.0/62.2 of h Return Air Ducts 'I 78.0 / 62.3 of ® 55.0 / 53.7 of Cooling Coil o..a. ,.., A;. n, ,..a.. Supply Air Ducts 55.0/53.7OF 41.2% R.H. ROOMS 78.0 / 62.2 of I I EnergyPro 4.0 by EnergySoft User Number. 5956 Job Number: 5082910 Page: 14 of 14 1