Loading...
BSOL2022-0212DESIGN & DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Permit Type: Solar Permit Number: BSOL2022-0212 Property Address: 80080 VISTA GRANDE APN: 600120004 Legal Description Property Zoning: Valuation: $29,000.00 BUILDING PERMIT PHONE (760) 777-7125 �� WWW.LAQUINTACA.GOV APPLIED DATE: 05/11/2022 eca QISSUED DATE: 06/30/2022 CALIFORNIA Owner: SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253 Applicant: Ara Petrosyan 16238 B Raymer Street, Van Nuys, CA 91406 Contractor: LA SOLAR GROUP INC DBA A P ELECTRICAL 16238 RAYMER ST UNIT B, VAN NUYS, CA 91406 PRIOR TO THE ISSUANCE OF THIS PERMIT FOR CONSTRUCTION, ALTERATION, IMPROVEMENT, DEMOLITION, OR REPAIR THE OWNER, APPLICANT AND/OR CONTRACTOR UNDER PENALTY OF PERJURY HAVE AFFIRMED WHEN APPLICABLE, THROUGH THE SUBMITTAL OF FORMS OR BY OTHER ELECTRONIC MEANS, THE FOLLOWING: LICENSED CONTRACTOR OR OWNER -BUILDER DECLARATION (1 or 2) 1) They are licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and the referenced License is in full force and effect, or; 2) That they are exempt from the Contractors' State License Law for the reason(s) indicated by either (2)(a) and/or (2)(b), or (2)(c) where he or she is exempt from licensure by a valid exemption. [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code] Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) a) As owner of the property, or my employees with wages as their sole compensation, will do all of or portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). b) As owner of the property, will be exclusively contracting with licensed c) Are exempt from licensure under the Contractors' State License Law. As an Owner -Builder, they acknowledge that, except for their personal residence in which they must have resided in for at least one year prior to completion of the improvements covered by this permit, they cannot legally sell a structure built as an owner -builder if it has not been constructed in its entirety by licensed contractors. It is understood that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application was submitted at the following Web site: http://www.leginfo.ca.gov/calaw.html. DECLARATION REGARDING CONSTRUCTION LENDING AGENCY (If applicable) A construction lender will be used for completion of the improvements covered by this permit and the name and information of which is on file for public inspection during the regular business hours of the public entity. Failure of the applicant to indicate the construction lender on the application does not relieve that person of the requirement to give the construction lender preliminary notice from that duty. WORKERS' COMPENSATION DECLARATION (1, 2 or 3) WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. 1) Has and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 2) Has and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 3) Certifies that, in the performance of the work for which this permit is issued, shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, shall forthwith comply with those provisions. NOTICE TO APPLICANT (1, 2 and 3) 1) Each person upon whose behalf this application was made, each person at whose request and for whose benefit work is being performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2) Any permit issued as a result of this application becomes null and void if work is not commenced within 360 days from date of issuance of such permit, or if cessation of work for 180 days will subject permit to cancellation. On or after January 1, 2019, every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 12 months after the time the work is commenced. 3) Certified that they read the application and state that the information provided is correct. Agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. IMPORTANT: An Application for Permit was made to the Building Official, subject to the conditions and restrictions set forth at the time of application, which is now hereby an Issued Permit. If any part of the information being supplied on this permit is inaccurate or untrue, please contact the City of La Quinta at (760) 777-7125 immediately for correction. Printed: 9/1/23 6:13 pm Page 1 of 3 1-3111111]1Z"a4 N IT, IkI Permit Type: Solar Permit Number: BSOL2022-0212 Property Address: 80080 VISTA GRANDE KING / 12.35kW PV SYSTEM, PV SUB & MSP UPGRADE - 19.35kW SOLAR ARRAY - (43) 450W LA SOLAR LS450BL PANELS W/ (9) HOYMILES HM-150ON & (4) HM-70ON MICROINVERTER, 125A PV SUBPANEL + NEW 200A SERVICE PANEL W/ 100A DEDICATED SOLA INPUT [860SF] 2019 CALIFORNIA BUILDING CODES. #111# KING / 12.35kW PV SYSTEM, PV SUB & MSP UPGRADE ` REVISION 1 - ADD 100A EXTERIOR AC DISCONNECT. System Size (kW DC) 19.35 PV Strings (EA) 5 PV Miscellaneous 2 Equipment EA Type Group Sq Ft Value Invoice No. Fee PERMIT-BSOL2022-021 PERMIT ISSUANCE 2 PV SYSTEM GREATER THAN 10KW PV SYSTEM MISC EQUIPMENT RECORDS MANAGEMENT FEE HOURLY CHARGE - CITY BUILDING STAFF BSAS SB1473 FEE PV SYSTEM MISC EQUIPMENT PC PV SYSTEM GREATER THAN 10KW PC TECHNOLOGY ENHANCEMENT FEE Total for Invoice PERMIT-BSOL2022-0212 Grand Total for Permit Fee Amount Amount Paid $105.60 $105.60 $41.68 $41.68 $55.58 $55.58 $11.00 $11.00 $41.75 $41.75 $2.00 $2.00 $55.58 $55.58 $41.68 $41.68 $5.00 $5.00 $359.87 $359.87 $359.87 $359.87 Workflow Step / Action Name Action Type Start Date End Date Application Completeness Check v.1 Submittal Document Verification v.1 Generic Action Plan Check v.1 Building Review (1 Day) Receive Submittal Permit Issuance v.1 Verify Contractor info & Conditions have been met v.1 Generic Action Verify & Invoice Fees v.1 Generic Action Verify Fee Payment & Issue Permit v.1 Generic Action Print, Attach, and Email Building Permit v.1 Create Report Solar Inspections v.1 Rough Electrical v.1 Inspection Rough Plumbing v.1 Inspection Temp Use of Permanent Power v.1 Inspection Inspections - Final v.1 Solar Final v.1 Inspection Printed: 9/1/23 6:13 pm Page 2 of 3 1-31111111]1Z"a4 N IT, IkI Permit Type: Solar Permit Number: BSOL2022-0212 Property Address: 80080 VISTA GRANDE Construction or work for which a permit is required shall be subject to inspection by the building official and such construction or work shall remain visible and able to be accessed for inspection purposes until approved. Approval as a result of an inspection shall not be construed to be an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel the provisions of the applicable code and other ordinances of the jurisdiction shall not be valid. It shall be the duty of the owner or the owner's authorized agent to cause the work to remain visible and able to be accessed for inspection purposes. Neither the building official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection. It shall be the duty of the holder of the building permit or their duly authorized agent to notify the building official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued a certificate of occupancy therefor as provided herein. Issuance of a certificate of occupancy shall not be construed as an approval of a violation of the provisions of the applicable code and other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the iurisdiction shall not be valid. A person shall not make connections from a utility, a source of energy, fuel, or power, or a water system or sewer system to any building or system that is regulated by the applicable code and other ordinances of the jurisdiction for which a permit is required, until approved by the building official. Printed: 9/1/23 6:13 pm Page 3 of 3 PROPERTY INFORMATION PROPERTY ADDRESS: 80080 Vista Grande, La Quinta, CA 92253, USA A.H.J. City of La Quinta PROJECT DESCRIPTION 43 LA SOLAR 450 WATT MODULES WITH 9 HOYMILES HM-1500,4HM-700 MICROINVERTERS 1 125A PV SUB PANEL 1 100A AC DISCONNECT PARCEL NUMBER: 600120004 PROPERTY TYPE: Single Family Residence VICINITY MAP OWNER: SYLVIA KING DESIGNED BY: Rafik Avagyan DATE: MAY 06, 2022 SYSTEM RATING 19.350KW DC (16.447KW AC) STC EQUIPMENT SUMMARY 43 LA SOLAR 450 WATT MODULES WITH 9 HOYMILES HM-1500,4HM-700 MICROINVERTERS GOVERNING CODES ALL CONSTRUCTION TO COMPLY WITH THE FOLLOWING CODES: t UNDERWRITERS LABORATORIES (UL) STANDARTS vimG��� OSHA 29 CFR 1910.296 • 2019 California Residential Code • 2019 California Green Building Standard Code a • 2019 International Property Maintenance Code • 2019 California Building Code, ; �,■es at La ;iintaSpring& • 2019 California Electrical Code, • 2019 California Plumbing Code, • 2019 California Mechanical Code, • 2020 California Fire Code, • 2019 California Energy Code, • 2019 California Administrative Code. • 2020 La Quinta Municipal Code STREET VIEW SHEET INDEX T-01 COVER PAGE PV -01 SITE MAP & PV LAYOUT PV -02 PROPERTY PLAN PV -03 GROUNDING & BONDING DETALS PV -04 ELECTRICAL 1 -LINE DIAGRAM PV -05 SYSTEM LABELING DETAIL PV -06 ATTACHMENT LAYOUT S-07 INVERTER DATA SHEET S-08 HOYMILES UL CATERIFICATE S-09 MODULE DATA SHEET S-10 MODULE CERTIFICATION S-11 RACKING SPECS S-12 RACKING CERTIFICATION AND ATTACHMENT SPECS S-13 SIEMENS MAIN PANEL WITH SOLAR INPUT SITE SPECIFICATIONS ONE STORY HOUSE CONSTRUCTION TYPE: VB OCCUPANCY GROUP: R3 REVISION 1 BSOL2022-0212 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ❑nTE09/13/2022 By IF ADD 100A EXTERIOR AC DISCONNECT CONTRACTOR LA SOLAR GROUP, INC Ara Petrosyan IMP ADDRESS: 16238 B Raymer St., Van Nuys, CA 91406 GENERAL NOTES LAS LAR EMAIL: Engineering@lasolargroup.com PHONE: (818) 373-0077 LIC #: 974115 LIC TYPE: C-46, C-10, C-39 All materials, equipment, Installation and work shall comply with the following applicable codes: 2019 CBC / 201916C, - 2019 CRC / 2019 IRC, - 2019 CEC,- 2019 CENC, - 2019 CMC / 2019 UMC, - 2019CPC/ 2019UPC, - 2019 CFC / 20191FC, - 2019 Building Energy Efficiency Standards • Existing plumbing vents, skylights, exhaust outlets, ventilations intake air openings shall not be covered by the solar photovoltaic system. • All outdoor equipment shall be NEMA 3R rated, including all roof mounted transition boxes and switches. • All equipment shall be properly grounded and bonded In accordance with CEC article 250. • All circuits connected to more than one source shall have over current devices located so as to provide over current protection from all sources. [CEC 690.9(A)] • The utility -interactive Inverters shall automatically de -energize Its output to the connected electrical production and distribution network upon loss of voltage in the system and shall remain in that state until the electrical production and distribution network voltage has been restored.[CEC 705.40] • Single conductor cable Type USE -2 and single conductor listed and identified as PV wire shall be permitted in exposed outdoor locations in PV source circuits within the PV array. PV wire shall be installed in accordance with 338.10(B)(4)(b) and 334.30. [CEC 690.31 (C)(1)] • The module conductors must be type USE -2 or listed for photovoltaic (PV) wire. [CEC 690.31(B)(1)] • PV system circuit conductors shall be identified at all accessible points of termination, connection, and splices . [CEC 690.31 (B(1)] • All grounded conductor shall be property color identified as white. [CEC 200.6] • PV system connected on the load side of the service disconnecting means of the other source(s) at any distribution equipment on the premises shall meet the following [CEC 705.12(B)] - Each source connection shall be made at a dedicated circuit breaker or fusible disconnecting means. [CEC 705.12(B)(1)] The sum of the ampere rating of the over current devices in circuits supplying power to the bus bar or conductor shall not exceed 120% of the rating of bus bar or conductor. (CEC 705.12(B)(2)(3)(b) The interconnection point shall be on the line side of all ground -fault protection equipment. [CEC 705.32] Equipment containing over current devices In circuits supplying power to a bus bar or conductor supplied from multiple sources shall be marked to Indicate the presence of all sources. [CEC 705.12(B)(3)] Circuit breaker, if back fed, shall be suitable for such operation. [CEC 705.12(B)(4)] • To minimize overheating of the bus bar In panel board, the panel board main circuit breaker and the PV power source circuit breaker shall be physically located at the opposite end of the bus bar.[CEC 705.12(B)(2)(3)(b)] • Marking and Labeling Methods and Locations. The labels or markings shall be visible after installation. The labels shall be reflective, and all letters shall be capitalized and shall be a minimum height of 9.5 mm (31 In.) in white on a red background. [CEC 690.31 (G)(4)] • Flexible, fine stranded cables shall be terminated only with terminals, lugs, devices or connector that are Identified and listed for such use. [CEC 690.31(H)] • Connectors shall be of latching or locking type. Connectors that are readily accessible and operating at over 30 volts shall require tool to open and marked "Do Not Disconnect Under Load' or 'Not For Current Interrupting". [CEC 690.33(C) & (E)(2)] • Equipment grounding conductor for PV modules smaller than 6AWG shall be protected from physical damage by a raceway or cable armor. [CEC 690.45 & 250.120(C)) • Equipment grounding conductor for PV systems without Ground Fault Protection (GFP) and installed on non -dwelling unit must have ampacity of at least 2 times the temperature and conduit fill corrected circuit conductor ampacity, [CEC 690.45(B)] • Fine -stranded cables used for battery terminals, devices, and connections requirelugs and terminals listed and marked for the use. [CEC 690.74 (A)] • " A permanent plaque or directory denoting the location of all electric power sourcedisconnecting means on or in the premises shall be installed at each service equipment location and at the location(s) of the system disconnect(S) for all electric power production sources capable of being interconnected" 2019 CEC 705.10 Directory • Fuses and Fixed -Trip Circuit Breakers. The standard ampere ratings for fuses and Inverse time circuit breakers shall be considered 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 130, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700,100, 1030, 1200, 1600, 2000, 2500, 3000,4000, 5030, and 6000 amperes. 690.9(A) • Protection devices for PV source circuits and PV output circuits shall be in accordance with the requirements of 690.9(C) • Where single overcurrent protection devices are used to protect PV source or output circuits, all overcurrent devices shall. be placed In the same polarity for all circuits within a PV system. The overcurrent devices shall be accessible but shall not be required to be readily accessible. 690.9 (C) -Equipment that performs the rapid shut down shall be listed and identified CEC.690.12 The rapid shutdown initiation methods shall be labeled in accordance with 690.56(B) •PV source circuits and PV output circuits shall not be contained in the same raceway. cable tray. cable. outlet box. junction box, or similar fitting as conductors, feeders, branch circuits of other non -PV systems, or Inverter output circuits, unless the conductors of the different systems are separated by a partition. CEC 690.31(8) • Where PV system do circuits run inside a building, they shall be contained in metal raceways.[CEC 690.31 (G)] SOLAR MODULES N 43 LASolar 450 Watt Gene al Noles Model #LS450BL CONTRACTOR: INVERTER INVERTER , • , LA Solar Group INVERTER TYPE: Micro: INVERTER TYPE: Micro: 9 HoyMiles 4 HoyMiles 16238 B Raymer St., Model#HM-1500N 240V S11 Model#HM-700N 240V S11 A. ALL WORK AHLL COMPLY WITH Van Nuys, CA 91406 THE CURRENT CALIFORNIA CODE Phone: (818) 373-0077 OF REGULATIONS TILTLE 24 AND LIC TYPE: C-46, C-10, C-39 MSP (N) Siemens 200A Main Service Panel - MANUFACTURERS LISTINGS. Lic#974115 With 100A Solar Input B. PRIOR TO CALLINGFOR FINAL / AC (N) 100A AC Disconnect 3' PVAmay5 ONSPECTION, THE CONTRACTOR PV A0 J 6 LA SOLAR 450W modules W 9 LA SOLAR 450 Wali modules iHM-1500,1HM-700N HOYMILES SHALL: PV(N) 125A PV Sub Panel 2HM-1500N,iHM-700N,HOYMILES Tilt 12 Deg Tilt"Deg 5 0 Azimuth: 64 De 1. BE COMPLETED WITH THE WORK. Azimuth: 334 De LAS� LAR (N)Junction Box 1 -6 5 2. HAVE A LADDER IN PLACE AND JB 3' \ SECURED TO THE ROOF> ------ EMT type Conduit ° Ara PetrosYan \ 0 5 5 HAVE THE SYSTEMENERGIZED Fire Setback Line ° READY FOR THE RUPID SHUTDOWN 3' 3 VERIFICATION 5 ------ HM -1500 O0 30 °° 1t 3 BY THE CITY INSPECTOR.(FAILURE , ° 3 TO COMPLY WITH THE ABOVE / 3 HM -700 3 a3 5/ - - ITEMS IS SUBJECT TO A 3 3 3' 5'/ � RE -INSPECTION FEE.) 5 3 4\ 4 5 PV MODULES SHALL MAINTAIN A 0 4\ 4 MINIMUM 12" HORIZONTAL 4 CLEARANCE FROM ALL PLUMBING 4'4 PV Arm 1 VENTS UNLESS ° 2L3HML1 00HAR 460Oyg WeILESit modules THE VENT IS EXTENDED SO AS TO 21SOLAR50W Watt modules ° '// 1 - JB#2 A.m. 154 BE ABOVE THE ARRAY. IHM-700 HOMILIES Q / ';I / 2 Til 12 Deg ° Azimuth: 334D 2 2 ROOF 3' 2 2 1 1 ACCESS' 3' working clearance in ° PV14 a50Wmodules front of equipment is SITE MAP & PV / 1 1 3HM-150lHM-700HOYMILES required by CEC 110.26 / Tilt: 12 Deg LAYOUT Azimuth. 154 De MSP - * Roof access is not located in areas that AC require placement of ground ladders over PV exterior wall openings CRC R331.4.1. JB#1 ae G tam �•�Stia O O Revision/Issue D CITY OF LA QUINTA EQUIPMENT ELEVATION BUILDING DIVISION Designed By: Rafik Avagyan REVIEWED FOR -- CODE COMPLIANCE 09/1€�nrE 30 /2022sr F Project Name and Address SYLVIA KING t D 80080 Vista Grande, La Quinta, CA 92253, USA 1 Projec PV SYSTEM Date MAY 06, 2022 PV 01 0 5' 10, s-iaAS SCALE INDICATED NOTE: CONDUIT SHALL BE PAINTED TO MATCH EXISTING SURFACE. A. ALL WORK AHLL COMPLY WITH THE CURRENT CALIFORNIA CODE OF REGULATIONS TILTLE 24 AND MANUFACTURERS LISTINGS. C Gene al Noles B. PRIOR TO CALLINGFOR FINAL ONSPECTION, THE CONTRACTOR SHALL: CONTRACTOR: W 1. BE COMPLETED WITH THE WORK. 2. HAVE A LADDER IN PLACE AND SECURED TO THE ROOF> W W W HAVE THE SYSTEMENERGIZED READY FOR THE RUPID SHUTDOWN W W W W W \ LA Solar Group VERIFICATION W W W W W W PROPERTY LINE 16238 B Raymer St., BY THE CITY INSPECTOR.(FAILURE TO COMPLY WITH THE ABOVE ITEMS IS �/ W W W W W W Van Nuys, CA 91406 SUBJECT TO A RE -INSPECTION FEE.) W W W W W W Phone: (818) 373-0077 PV MODULES SHALL MAINTAIN A MINIMUM 12" HORIZONTAL CLEARANCE FROM W W W W W W W W W W W W W W y W W W W W W W W LIC TYPE: C-46, C-10, C-39 ALL PLUMBING VENTS UNLESS W W W W W W W W W W W W W THE VENT IS EXTENDED SO AS TO BE ABOVE THE ARRAY. W W W W W W W W W W \ Lic # 974115 W W W W W W W W W W W W W W W LASOLAR Q R O V p Ara Petrosyan W W W W W W W W W W W W W W W W W W D W W W W CITY OF LA QUI NTA BUILDING DN1510N REVIEWED FOR CODE COMPLIANCE ' X09/13/2022 gY__JF_ W W W W W W W W W W 2 \\ W W W W W W W W W W D 0 \ O W W W W W W W W W W W W W W W W W D \ \ W W W W W W W O PROPERTY O 5'-2" PLAN \W W O O O O O O W V W W ° \ O ® O D '// O O O O O \ o O° / bRIVEWAY No. Revision/Issue Date o ° �/ D G / Designed By: p // // /j ° Rafik Avagyan M S P Name and Address ACProject LEGEND /'/ /j//'/j//'/j//'/ \Stia�'ta�ae SYLV IA KING 80080 Vista Grande, La Quinta, CA 92253, USA MSP Main Service Panel /i / /i / / Project PV PV Sub Panel /'//'i / PV SYSTEM Dat' ----IPV MAY 06, 2022 PV 02 AC AC Disconnect SCALE 0 5' 10 Sale AS INDICATED SOLAR MODULES 43 LASolar 450 Watt Model#LS450BL INVERTER INVERTER INVERTER TYPE: Micro: INVERTER TYPE: Micro: 9 HoyMiles 4 HoyMiles Model#HM-1500N(240V) [S11] Model#HM-700N(240V) [S11] 1 "New main service panel has CITY OF LA QUINTA 200AMain breaker BUILDING DIVISION and has additional 100A space for REVIEWED FOR Alternative Energy Input CODE which will be used for Solar system" COMPLIANCE Over HeadA l UTILITY INSTALL 90A DATE09/13/2022 By --IF �/�\� RAAINI /D INSTALL (5)20A PV �( (6) #10 AWG THWN/THWN-2 2 -POLE C/B \ (1) #8 AWG GND (2) #12 AWG PV WIRE 3/4" EMT 20 FEET (1)#6 AWG EGC FREE IN THE AIR -------------� n I m I 2 ••• 8 I J BOX #1 N NEMA3R 1 /� i BRANCH CIRCUIT #1 MODULES 8, 2HM+1500 I I 2 6 BRANCH CIRCUIT #2 ° + r MODULES 8, 1 HM -1 500,2HM-700 I I \ I I I 1 2 8 r� _J BRANCH CIRCUIT #3 ° MODULES 8, 2HM-1500,1 HM -700° I J BOX #2 NEMA3R I 2 6 I BRANCH °°° r ,I CIRCUIT #4 ° MODULES 8. 2HM-1500 I 1 I I I 2-1 10 BRANCH CIRCUIT #5 Ut MODULES 10, 21 -IM -1500,11 -IM -700 ALL WIRES WILL BE CONNECTED WITH 600V RATED WIRE NUTS WITH SEALANT CONNECTORS SHALL BE LOCKING, TOOL TYPE CONNECTION TO THE INTERIOR METAL WATER PIPING SHALL BE MADE WITHIN 5FT. FROM THE POINT OF ENTRANCE. PER SECTION 250.68(C)(1). Cold Water bond wwithin 5feet and at leaste 1 supplemental electrode are required. Art. 250.50 250.53(D)(2) LAEC Article 250.104 Bonding of Piping Systems and Exposed Structural Steel CODE LANGUAGE: (A) Metal Water Piping. The metal water piping system shall be bonded as required in (A)(1), (A)(2),or (A)(3) of this section. The bonding jumper(s) shall be installed in accordance with 250.64(A), (B), and (E). The points of attachment of the bonding i PV DISTRBT. PANEL 125A, 120/24OV, NEMA3R (3) #4 AWG THWN/THWN-2 (1) #8 AWG GND 1” EMT,2 FEET (4) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT. 45 FEET 100A NON FUSED AC DISCONNECT, ten ✓gni LOCKABLE,BLADE TYPE, aur xxin l+,rv� NEMA3R WIRE SVE CALCULATION 120 / 240V (UTILITY REQUIRED) INSTALL 90A 2P CB(PV) READILY ACCESSIBLE SWITCH THAT PLAINLY INDICATES WHETHER IT IS IN INSTALL AT ALTERNATE THE "OFF” OR "ON" POSITION ENERGY INPUT / 200A MAIN C/B � I If (3) #4 AWG THWN/THWN-2 (1) #8 AWG GND METER (N) GROUNDING ELECTRODE SYSTEMA -GEC e usr+•a ten ✓gni PWAIAATIUTItl6 aur xxin l+,rv� POFMICROINVERTERSIN WIRE SVE CALCULATION MICRO INV ERTE R 3R-A<ER5IZEPER (5k9ryttfrRfl+i Y1 w"R' '.r.+wx.�•.°,r .'°v,•,� zaR:.r[leRRnrs reculn:ccvux BRAN CITCIRcurral CIRC :Jfr 5.99'1.75=74975 MAXIMUM 0UTPJT B. CBCT MICROINVERTER 2 COftRENT x lily„e—,inl HOF.MiCROINVERTERS IN BRANCH CIRCUTTOTAL CURRENT, 2 MAXIMUM QUIP JE 3R--AKERSREPER BRANCH CIRCUI743 unrssrc CIRCJIT 5.99"L25=14,975 CURRENT 3. CBCT WEAr10Y 6 1 1, .:IOI:.Y[IP.RCN rS RICOIII: ir�liifA i Inlynele+nu.lwor+ nN rSo]xlurn'I BOF.MiCROINVERTERSIN BRANCH CIRCUIT TOTAL CURRENT, 1' 29 MAXIMUM ❑UTP Ji 3R-A�LER SIZE PER ;Imp 2 2 599 1,25 114.96 1 A 5,99 1 A ZP A rtcor rar a iw unc x,n. III IV Ha m vrstNrY�Auul.,•nw•!Iv Yco.n.tc+r�.. BRANCH CI RCUI T 42 1 7-77-7-777A 29 A ZP n ' •r N OFMICROI NVERTERS I N B RA NCH CI R1 -I-1 IT TOTAL CU RRENT, 1° MICRO INV ERTER PIR _AKEA SIZE PER CIRCJIT 599•t.25=7.0.875 MAM MUM C UTP J1 R. CBCT NnRe4:s ,+.r .,r.,rllr: anuli+ elan:r+f iA(Urr7 .1 RIKRr„�rrRrrxs sniNv[rtr;xt s.I:,nI1Y 11OFMICROINVER71FRSIN CIRCJrt CURRENT BRFA:CER SIZE PER 20AYIMVM 0UTPJP R. CBCT e N+rx,i a>t: ,ytnRi 1 nvy„.teSVIM +'rad, nVs iX[H1+w n L 1 I 599 1.25 1 7.49 1 A 599 1 A 20 1 A u•f,w,a asr goo+ Y c1y ,I.riw wn-n,Rl x+w, BRANCf{CIRCUIT Irl 2 1 599 1.25 14.98 A 599 1 A 20 1 A +i+allnr f.sxvil. n+cnw.I �'+sv. -5xinrteaxen, al.,u.vnrer. M:CROINVERTER ,�,-•,wnn s[ nn u[(tx:vrroa IpFICRpIRVERTER$IN BRANCH CIRCUITTOTLCVRNT,3`2, MA(IALMOU1PJr j11--A;EASIZCPCR 14i. CIRCJT 1.Z5°7,25 CURRENT (RCT W%]V nl� ! t'A x11Y W.,II• L. 2 2 1 29 1 L25 1 7.25 1 A 29 I A 1 20 1 A e usr+•a ten ✓gni r tr,lrr,l,.. ww. rxx, aur xxin l+,rv� POFMICROINVERTERSIN BRANCH CIRCUITTOTAL CURRENT, 2` MICRO INV ERTE R 3R-A<ER5IZEPER lacanov w"R' '.r.+wx.�•.°,r .'°v,•,� zaR:.r[leRRnrs reculn:ccvux CIRC :Jfr 5.99'1.75=74975 MAXIMUM 0UTPJT B. CBCT 2 COftRENT t h}?r rC•, 1 wall. 1.,r n v.iw w :w repo ................................................" ... 2 S 99 1.7.5 114.98 A 5.99 A 20 A BRANCH CIRCUI743 MICROINVERTER IntraYa r, YSl;oel i Inlynele+nu.lwor+ nN rSo]xlurn'I BOF.MiCROINVERTERSIN BRANCH CIRCUIT TOTAL CURRENT, 1' 29 MAXIMUM ❑UTP Ji 3R-A�LER SIZE PER CIRCJIT '1.25=i625 3. CBCT C,IRRENT toc4no” III IV Ha m vrstNrY�Auul.,•nw•!Iv Yco.n.tc+r�.. 1 1 7-77-7-777A 29 A ZP n ' •r BRANCIH CJRCUIT94 MICROINVERTER NnRe4:s ,+.r .,r.,rllr: anuli+ elan:r+f iA(Urr7 .1 RIKRr„�rrRrrxs sniNv[rtr;xt s.I:,nI1Y 11OFMICROINVER71FRSIN CIRCJrt BRANCH CIRtI-ITTOTAt CURREINT, 2° = 5.99•t.2514975 BRFA:CER SIZE PER 20AYIMVM 0UTPJP R. CBCT >7p, CURRENT u•f,w,a asr goo+ Y c1y ,I.riw wn-n,Rl x+w, 7 2 1 599 1.25 14.98 A 599 1 A 20 1 A .n. BRANCH ClRCUITS IOCar •? .•..�.t.....,...:.I... u[(tx:vrroa H pF MICCIRCji ERTERSIN 6RANCH CIRCUIT Ct1RREP+T,2° MICRO INV ERTE R BREq.(ER 512E PER W%]V nl� ! t'A x11Y W.,II• L. CIRCJIT 2521. 5-95' 1.25= 14,975 MAXI MUM QUIP JT B. CBCT -777-77-7A CURRENT 2 2 I—, -T 5.99 1 A 20 A a Cn,cwi+r.• Y°i1 i061 i xrmNle+lru.,+oor: xRl.rmcr 4-1 BRANCH CIRCUIT RS MICRO INV ERTE R ..,...1.,. W.'.RSSICHI Y7 wxw*vwu1.8'ow•]iio 'V1TY1'.'n.,. .,rx,u.. nr.x. FOF MICRONVERTERSIN CIRC :Jfr BRANCH CIRCUTTOTALLURREN7.1`24 '1.75-3.625 MAXI MUM ❑LJIP JI 3R _A(ER SIZE PER B. CRCT 1' w I�F ,tar: n v.rk w CURRENT RIF lu.f% A Y rNY n.a v 1 1 1 2.9 1 1.25 1 3.63 1 A 2.9 1 A 27T A YInpl.sq;R I1.V ."•1l qt unnli nRAn :t+f ACUI r} rtxt xr"rlwer-xR s.I:,n11V FROM l807f T4 PV511B PANEL RACEWAY TEMP DEBATE FACTO3{max. MORE THAN WIRE SIZE MAXIMUM HFIGHT.`ROM t7oF wntinlo�s wrrrn: d�vlded AOJI;STEb CONDUCTOR 3CCCaD15T FROM NEC gNIS 1ENTTEM FACFQR PER str Hx. CONTINUOUS vlires{# AWACITY, 25.2!0$= lo[arI•?r aR+1ar[W.n[Nn .1D['tn:v(eroCC RO4F(TEMP CI.RRENT ambient tem, FaGtpr], 1e,6j or 6C+21 FACTOR 32.75 TABLE NECTASLE 330.15Ih1[2][d1 39+17-�,6C] 0-71 =2S2A WIRE5 310 lS1h116 wYl+rrl� z1• iNl� w,,ll, 18.50 -1 W..I L86 1 011 1 Xfl A 5 1 0.V] 3L75 I A I Ur AW- 0.71 FTtUM PV SUB PANEL T4 MAIN PANEL - Ynscui +:<• --I Y TOTALtr OF TOTALA5 FROM ALL WIRE54E AMBENTTEM TEPo1P_DERATE Fl1CTORICC9IATTHE CONSIDER CONTINUOUS M.CRDINV ERT rr11CROINVERTER5, 9'S.99t4'29• , 65.51 FROMNEC FACTOR PER WALL OFTHE BiIILD NG1.8181?7;0 �.91= wt..1.,r wart;51:1Ns7 wxlsllepC'trt�l.l'n»•9V . . •. ,,,,_,.,,, „r.r .,,.,v.r•ar.u< ERY Gi.51A RL?S=91.9A 908 TABIE NECTA6,E .,„ LC.........4 10 I.— a VOW, +1.5 f0.. v ..,.....,,. 13 13 ........ ...... 5,99, 28 65,51 A 65,51 1,25 ...,,. .....�.. 81.89 A 57,9 Q9i 89,99 318151 h116 318 ]St h](2)t a} ..� d 4AWG 1) 91 CGene al Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR Ara Petrosyan ELECTRICAL 1 -LINE DIAGRAM Ll -JU O O No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Projec PV SYSTEM Date PV 04 MAY 06, 2022 Scale AS INDICATED PROPERTY INFORMATION PROPERTY ADDRESS: 80080 Vista Grande, La Quinta, CA 92253, USA A.H.J. City of La Quinta PARCEL NUMBER: 600120004 PROJECT DESCRIPTION 43 LA SOLAR 450 WATT MODULES WITH 9 HOYMILES HM-1500,4HM-700 MICROINVERTERS 1 125A PV SUB PANEL PROPERTY TYPE: Single Family Residence VICINITY MAP OWNER: 1�7�9[el�l��] X71 DATE: SYLVIA KING Rafik Avagyan MAY 06, 2022 SYSTEM RATING 19.350KW DC (16.447KW AC) STC EQUIPMENT SUMMARY 43 LA SOLAR 450 WATT MODULES WITH 9 HOYMILES HM-1500,4HM-700 MICROINVERTERS GOVERNING CODES ALL CONSTRUCTION TO COMPLY WITH THE FOLLOWING CODES: UNDERWRITERS LABORATORIES (UL) STANDARTS OSHA 29 CFR 1910.296 • 2019 California Residential Code • 2019 California Green Building Standard Code • 2019 International Property Maintenance Code • 2019 California Building Code, • 2019 California Electrical Code, • 2019 California Plumbing Code, • 2019 California Mechanical Code, • 2020 California Fire Code, • 2019 California Energy Code, • 2019 California Administrative Code. • 2020 La Quinta Municipal Code SHEET INDEX T-01 COVER PAGE PV -01 SITE MAP & PV LAYOUT PV -02 PROPERTY PLAN PV -03 GROUNDING & BONDING DETALS PV -04 ELECTRICAL 1 -LINE DIAGRAM PV -05 SYSTEM LABELING DETAIL PV -06 ATTACHMENT LAYOUT S-07 INVERTER DATA SHEET S-08 HOYMILES UL CATERIFICATE S-09 MODULE DATA SHEET S-10 MODULE CERTIFICATION S-11 RACKING SPECS S-12 RACKING CERTIFICATION AND ATTACHMENT SPECS S-13 SIEMENS MAIN PANEL WITH SOLAR INPUT SITE SPECIFICATIONS ONE STORY HOUSE CONSTRUCTION TYPE: VB OCCUPANCY GROUP: R3 90D80 Vista Grande. La Ql10%CA 92253, LISA vier - 9 des at La �jrrtta Springs STREET VIEW 01.1. r BSOL2022-0212 19.35kW SOLAR ARRAY - a9. (43) 450W LA SOLAR LS450BL PANELS W/ (9) HOYMILES HM-150ON & (4) HM-70ON MICROINVERTER, 125A PV SUBPANEL + NEW 200A SERVICE PANEL W/ 100A DEDICATED SOLAR INPUT [860SF] 2019 CALIFORNIA BUILDING CODES. CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ,,,,06/16/2022 e, 3F CONTRACTOR LAS LAR LA SOLAR GROUP, INC EMAIL: Engineering@lasolargroup.com Ara Petrosyan PHONE: (818) 373-0077 ADDRESS: 16238 B Raymer St., Van Nuys, CA 91406 LIC #: 974115 LIC TYPE: C-46, C-10, C-39 GENERAL NOTES All materials, equipment, Installation and work shall comply with the following applicable codes: 2019 CBC / 20191BC, - 2019 CRC / 2019 IRC, - 2019 CEC,- 2019 CENC, - 2019 CMC / 2019 UMC, - 2019CPC/ 2019UPC, - 2019 CFC / 20191FC, - 2019 Building Energy Efficiency Standards • Existing plumbing vents, skylights, exhaust outlets, ventilations intake air openings shall not be covered by the solar photovoltaic system. • All outdoor equipment shall be NEMA 3R rated, including all roof mounted transition boxes and switches. • All equipment shall be properly grounded and bonded In accordance with CEC article 250. • All circuits connected to more than one source shall have over current devices located so as to provide over current protection from all sources. [CEC 690.9(A)] • The utility -interactive Inverters shall automatically de -energize Its output to the connected electrical production and distribution network upon loss of voltage in the system and shall remain in that state until the electrical production and distribution network voltage has been restored.[CEC 705.40] • Single conductor cable Type USE -2 and single conductor listed and identified as PV wire shall be permitted in exposed outdoor locations in PV source circuits within the PV array. PV wire shall be installed in accordance with 338.10(B)(4)(b) and 334.30. [CEC 690.31 (C)(1)] • The module conductors must be type USE -2 or listed for photovoltaic (PV) wire. [CEC 690.31(B)(1)] • PV system circuit conductors shall be identified at all accessible points of termination, connection, and splices . [CEC 690.31 (13(1)] • All grounded conductor shall be property color identified as white. [CEC 200.6] • PV system connected on the load side of the service disconnecting means of the other source(s) at any distribution equipment on the premises shall meet the following [CEC 705.12(B)] Each source connection shall be made at a dedicated circuit breaker or fusible disconnecting means. [CEC 705.12(B)(1)] The sum of the ampere rating of the over current devices in circuits supplying power to the bus bar or conductor shall not exceed 120% of the rating of bus bar or conductor. (CEC 705.12(B)(2)(3)(b) The interconnection point shall be on the line side of all ground -fault protection equipment. [CEC 705.32] Equipment containing over current devices In circuits supplying power to a bus bar or conductor supplied from multiple sources shall be marked to Indicate the presence of all sources. [CEC 705.12(B)(3)] Circuit breaker, if back fed, shall be suitable for such operation. [CEC 705.12(B)(4)] • To minimize overheating of the bus bar In panel board, the panel board main circuit breaker and the PV power source circuit breaker shall be physically located at the opposite end of the bus bar.[CEC 705.12(B)(2)(3)(b)] • Marking and Labeling Methods and Locations. The labels or markings shall be visible after installation. The labels shall be reflective, and all letters shall be capitalized and shall be a minimum height of 9.5 mm (31 In.) in white on a red background. [CEC 690.31 (G)(4)] • Flexible, fine stranded cables shall be terminated only with terminals, lugs, devices or connector that are Identified and listed for such use. [CEC 690.31(H)] • Connectors shall be of latching or locking type. Connectors that are readily accessible and operating at over 30 volts shall require tool to open and marked "Do Not Disconnect Under Load' or 'Not For Current Interrupting". [CEC 690.33(C) & (E)(2)] • Equipment grounding conductor for PV modules smaller than 6AWG shall be protected from physical damage by a raceway or cable armor. [CEC 690.45 & 250.120(C)) • Equipment grounding conductor for PV systems without Ground Fault Protection (GFP) and installed on non -dwelling unit must have ampacity of at least 2 times the temperature and conduit fill corrected circuit conductor ampacity, [CEC 690.45(B)] • Fine -stranded cables used for battery terminals, devices, and connections requirelugs and terminals listed and marked for the use. [CEC 690.74 (A)] • " A permanent plaque or directory denoting the location of all electric power sourcedisconnecting means on or in the premises shall be installed at each service equipment location and at the location(s) of the system disconnect(S) for all electric power production sources capable of being interconnected" 2019 CEC 705.10 Directory • Fuses and Fixed -Trip Circuit Breakers. The standard ampere ratings for fuses and Inverse time circuit breakers shall be considered 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, BO, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700,100, 1030, 1200, 1600, 2000, 2500, 3000,4000, 5030, and 6000 amperes. 690.9(A) • Protection devices for PV source circuits and PV output circuits shall be in accordance with the requirements of 690.9(C) • Where single overcurrent protection devices are used to protect PV source or output circuits, all overcurrent devices shall. be placed In the same polarity for all circuits within a PV system. The overcurrent devices shall be accessible but shall not be required to be readily accessible. 690.9 (C) -Equipment that performs the rapid shut down shall be listed and identified CEC.690.12 The rapid shutdown initiation methods shall be labeled in accordance with 690.56(B) •PV source circuits and PV output circuits shall not be contained in the same raceway. cable tray. cable. outlet box. junction box, or similar fitting as conductors, feeders, branch circuits of other non -PV systems, or Inverter output circuits, unless the conductors of the different systems are separated by a partition. CEC 690.31(8) • Where PV system do circuits run inside a building, they shall be contained in metal raceways.[CEC 690.31 (G)] SOLAR MODULES N 43 LASolar 450 Watt General Notes Model#LS450BL CONTRACTOR: INVERTER INVERTER 0 LA Solar Group INVERTER TYPE: Micro: INVERTER TYPE: Micro: 9 HoyMiles 4 HoyMiles 16238 B Raymer St., Model#HM-1500N 240V S11 Model#HM-700N 240V S11 A. ALL WORK AHLL COMPLY WITH Van Nuys, CA 91406 THE CURRENT CALIFORNIA CODE Phone: (818) 373-0077 OF REGULATIONS TILTLE 24 AND LIC TYPE: C-46, C-10, C-39 MSP (N) Siemens 200A Main Service Panel - MANUFACTURERS LISTINGS. Lic#974115 With 100A Solar Input / B. PRIOR TO CALLINGFOR FINAL 3' PVA"ay5 ONSPECTION, THE CONTRACTOR JB (N)Junction Box PV A"ay4 9 LA SOLAR 450 Walt modules 2HM-i500N,iHM-700N,HOVMILES Tilt:4 Deg Azimuth: 334 De J 6 LA SOLAR 45OW modules 1HM-1500,1141A-700N HOVMILES 5 O Tilt 12 Deg 0 Azimuth: 64 De 4D SHALL: 1. BE COMPLETED WITH THE WORK. LASOLAR PV (N) 125A PV Sub Panel 3' 1'-6" \ 5 2. HAVE A LADDER IN PLACE AND ------ EMT type Conduit` ° SECURED TO THE ROOF> Ara PetrosY an 5 5 HAVE THE SYSTEMENERGIZED Fire Setback Line'1 \ READY FOR THE RUPID SHUTDOWN 3' 355 VERIFICATION ------ HM -1500 030 ° °° 1t \ 3 BY THE CITY INSPECTOR.(FAILURE , 3 TO COMPLY WITH THE ABOVE HM -700 / 3 3 a3 5/ - - ITEMS IS SUBJECT TO A 3 3 3' 5// ; 5 RE -INSPECTION FEE.) 3 4\ / 4 5 PV MODULES SHALL MAINTAIN A 0 4 4 4 MINIMUM 12" HORIZONTAL `4 '4 CLEARANCE FROM ALL PLUMBING PV Ams1 / \ 12 LA SORPV VENTS UNLESS Array3 // \ 3 HML1005HOVMILES ales Tih: 12 Deg THE VENT IS EXTENDED SO AS TO 2LAIHM 0 450 Watt 0HOYMILEStlules °o / 3 / 2 JB#2 A=�m.6.:154De BE ABOVE THE ARRAY. Tilt: 12 Deg ° Azimuth: 334D 2 ' 3' 2 2 ROOF 2 1 ACCESS' 3' working clearance in \ ° 2 1 PVAray2 1 front of equipment is SITE MAP & PV / 14 LA SOLAR 40W modules 1 1 3HM-1500,IMM-700HOYMILES Tilt: 12 Deg required by CEC 110.26 LAYOUT MSP - / Azimuth. 154 De 1 * Roof access is not located in areas that PV require placement of ground ladders over JB#1 ae exterior wall openings CRC R331.4.1. Ggar �•�Stia QROFESc No. Revision/Issue Date CITY OF LA QUINTA C 84486 BUILDING DIVISION REviODEFOR Designed By: EQUIPMENT ELEVATION COMPLIANCE`S'T CIVI �P Rafik Avagyan osn s/2ozz �, qTF OF Dpi 1F0�� Project Name and Address EXP 09/30/2023 SYLVIA KING 80080 Vista Grande, La Quints, CA 92253, USA 4Project PV SYSTEM Dale MAY O6, 2022 PV 01 0 5' 10, Scale SCALE AS INDICATED NOTE: CONDUIT SHALL BE PAINTED TO MATCH EXISTING SURFACE. A. ALL WORK AHLL COMPLY WITH THE CURRENT CALIFORNIA CODE OF REGULATIONS TILTLE 24 AND MANUFACTURERS LISTINGS. C Gene al Noles B. PRIOR TO CALLINGFOR FINAL ONSPECTION, THE CONTRACTOR SHALL: CONTRACTOR: W 1. BE COMPLETED WITH THE WORK. 2. HAVE A LADDER IN PLACE AND SECURED TO THE ROOF> W W v HAVE THE SYSTEMENERGIZED READY FOR THE RUPID SHUTDOWN W W W W W \ LA Solar Group VERIFICATION W W W W W W PROPERTY LINE 16238 B Raymer St., BY THE CITY INSPECTOR.(FAILURE TO COMPLY WITH THE ABOVE ITEMS IS �/ W W W W W W Van Nuys, CA 91406 SUBJECT TO A RE -INSPECTION FEE.) W W W W W W Phone: (818) 373-0077 PV MODULES SHALL MAINTAIN A MINIMUM 12" HORIZONTAL CLEARANCE FROM W W W W W W W W W W W W W y W W W W W W W W LIC TYPE: C-46, C-10, C-39 ALL PLUMBING VENTS UNLESS W W W W W W W W W W W W W THE VENT IS EXTENDED SO AS TO BE ABOVE THE ARRAY. W W W W W W W W W W \ Lic # 974115 LASOLAR G R O U P W W Y W W W W W W W W W W W W W W W W W W W W Q W W Ara Petrosyan •D //// //// \W W W W W W �r_l trr W W W •D W W W W W W W W W W 2' \\ W W W W W \W W W W W W W W W W W W W D Q Q Q O \ O W W W W W W W W W W W W W W W W W W W W W W W D W W W 0 0� \ W W W W W W W O PROPERTY O 5'-2" PLAN \W W O O O O O O W V W W \ O CITY OF LA QUINTA \ ® O D / / /// O D 0 BUILDING DIVISIONNo. REVIEWED FOR CODE ° °° , o o / bRIWAY / D /j Revision/Issue Date COMPLIANCE ,,06/16/2022 , \ / / DI>/ Designed By ° Rafik Avagyan MSP // // // // Project Name and Address P / / / / / / ��stiac'ta�ae SYLV IA KING 80080 Vista Grande, La Quinta, CA 92253, USA LEGEND Project PV SYSTEM MSP Main Service Panel /D /i / / MAYD6.2D22 PV 02 PV PV Sub Panel SCALE Sale AS INDICATED oGenerel Noles CONTRACTOR: LA Solar Group CZARRAY © Wm Photovoltaic Roof Mounted 16238 B Raymer St., Van Nuys, CA 91406 a a $ Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 _ GROUNDING NOTES C cpi a CD.t s 12 – – – t ca Equipment grounding Conductor EGC/ Grounding Electrode Cunductor (GEC) Lic # 974115 Z~ c+`+'2i –• _ a. Size Equipment Grounding Cunductor per NEC 250.122 J — _ °� V -V) t7 a) Module/ Racking b. Size Grounding Electrode Cunductor per NEC 250.166 Bonding see detail c. EGC & GEC May be a combined conductor Per 690.47(C) (1), (2) or (3) EGC d. All grounding and bonding of the PV system shall comply with Cit Requirements. per 250.122 g 9 9 Y P Y Y Q LASOLAR a a o u a – – a - Note: Weeb plates, washers and similar devices are not approved Ara Petrosyan 13 r- `o 0)E E Combiner Box AC UTILITY MAIN SERVICE SWITCHBOARD INVERTER DISCONNECT M _ o =� EGC per 250.122 psi o EGC J N _ r o � EC ATTACH NEW GEC TO EXISTING BY IRREVERSABLE MEAN � its ro E 8 * For grounding and bonding of module follow manufactures installation instructions listing & NEC L 4 j G 6 110.3 (B) Z ,.2 c 0 0 GROUNDING DETAILS Lay -in -Lug Listed to UL 2703 GROUNDING & I HELIO Grounding Lug Micro Inverter Installation BONDING o DETAILS c o of o � E Micro Inverter Inverter Out ut Circuits EWPM nt Grounding Conductor Trunk Cable E C ® ® ® 8 rc 2 2 9) LU o rn I 0 \ m v Lo n E = o i3 Revision/Issue Date - F 2 D1 LUw Junction Box (D 0. Za ZM \ R � Micro Inverter Goundi Standard rail rn A. System &End Connection Designed By Y e I ❑ a)o� � s o Notes Rafik Avagyan Cl U '6 1. Grounding electrode conductor shall be #6 AWG. C7 " r 2. Ironridge Integrated Grounding system. No additional ground lugs needed Pmjea Name and Addmas Q y w o 18 o E Owa 3. UL listed Ground lugs will be applied only for rail -to -rail (for parallel rails only) a N M 31 ° EC' 's fl o The Enphase M250 Microinverter delivers increased energy harvest and reduces design and installation SYLVIA KING J2 E °' C67 v complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated from ground, $0080 Vista Grande, a ❑ E `o E a 3 o :3i�s so no Ground Electrode Conductor (GEC) is Required for the Microinverter. La Quinta, CA 92253, USA ! I p ._ @ -� �� o m v Q rn W GEC shall be installed in one continuous length without a splice or joint. Splicing Pme� PV SYSTEM j shall be permitted only by irreversible compression -type connectors listed as grounding and bonding equipment or by exothermic welding process per CEC Art Date MAY 06, 2022 P V 03 250.64(C) (1) AS INDICATED SOLAR MODULES 43 LASolar 450 Watt Model#LS450BL INVERTER INVERTER INVERTER TYPE: Micro: INVERTER TYPE: Micro: 9 HoyMiles 4 HoyMiles Model#HM-1500N(240V) [S11] Model#HM-700N(240V) [S11] (6) #10 AWG THWN/THWN-2 INSTALL 90A INSTALL (5)20A PV BRANCH ° ° ° 1J' I` I — — CIRCUIT #1 MODULES 8, 2HM+1500 1 I 2 6 BRANCH(4) ° 1 I I (4) #10 AWG THWN/THWN-2 CIRCUIT #2 (1) #8 AWG GND MODULES 8, 1HM-1500,2HM-700+ 1 I ` -- 3/4" EMT. 45 FEET 1 � I ... 9 I 1 2 BRANCH °°° 1� CIRCUIT #3 MODULES 8, 2HM-1500,1 HM -700+ I J BOX #2 1 NEMA3R I 2 8 I, J BRANCH °°° 11 CIRCUIT #4 ° MODULES 8, 2HM-1500 I I I 1 2 ... 10 1 �; J BRANCH °°° CIRCUIT #5 + MODULES 10, 2HM-1500,lHM-700 ALL WIRES WILL BE CONNECTED WITH 600V RATED WIRE NUTS WITH SEALANT CONNECTORS SHALL BE LOCKING, TOOL TYPE CONNECTION TO THE INTERIOR METAL WATER PIPING SHALL BE MADE WITHIN 5FT. FROM THE POINT OF ENTRANCE. PER SECTION 250.68(C)(1). Cold Water bond wwithin 5feet and at leaste 1 supplemental electrode are required. Art. 250.50 250.53(D)(2) LAEC Article 250.104 Bonding of Piping Systems and Exposed Structural Steel CODE LANGUAGE: (A) Metal Water Piping. The metal water piping system shall be bonded as required in (A)(1), (A)(2),or (A)(3) of this section. The bonding jumper(s) shall be installed in accordance with 250.64(A), (B), and (E). The points of attachment of the bonding (1) #8 AWG GND (2) #12 AWG PV WIRE (1)#6 AWG EGC 3/4" EMT 20 FEET FREE IN THE AIR 200AMain breaker -------------� I rS RlLtllll: ir�liifA and has additional 100A space for ° • ° 8 Alternative Energy Input I I J BOX #1 CURRENT 2 ”+R �xNx{�^I L Over Head UTILITY IN M I 3 1 INSTALL 90A INSTALL (5)20A PV BRANCH ° ° ° 1J' I` I — — CIRCUIT #1 MODULES 8, 2HM+1500 1 I 2 6 BRANCH(4) ° 1 I I (4) #10 AWG THWN/THWN-2 CIRCUIT #2 (1) #8 AWG GND MODULES 8, 1HM-1500,2HM-700+ 1 I ` -- 3/4" EMT. 45 FEET 1 � I ... 9 I 1 2 BRANCH °°° 1� CIRCUIT #3 MODULES 8, 2HM-1500,1 HM -700+ I J BOX #2 1 NEMA3R I 2 8 I, J BRANCH °°° 11 CIRCUIT #4 ° MODULES 8, 2HM-1500 I I I 1 2 ... 10 1 �; J BRANCH °°° CIRCUIT #5 + MODULES 10, 2HM-1500,lHM-700 ALL WIRES WILL BE CONNECTED WITH 600V RATED WIRE NUTS WITH SEALANT CONNECTORS SHALL BE LOCKING, TOOL TYPE CONNECTION TO THE INTERIOR METAL WATER PIPING SHALL BE MADE WITHIN 5FT. FROM THE POINT OF ENTRANCE. PER SECTION 250.68(C)(1). Cold Water bond wwithin 5feet and at leaste 1 supplemental electrode are required. Art. 250.50 250.53(D)(2) LAEC Article 250.104 Bonding of Piping Systems and Exposed Structural Steel CODE LANGUAGE: (A) Metal Water Piping. The metal water piping system shall be bonded as required in (A)(1), (A)(2),or (A)(3) of this section. The bonding jumper(s) shall be installed in accordance with 250.64(A), (B), and (E). The points of attachment of the bonding IOLA[IOY :I'.lav .:F:.Y[IP.PEX rS R1L`alR: ITAT fA n•ml. •'.1. ,u m}x'c' J1 150 I'•a LAI a v.in w v e50 ]BOD ...... ............................. . [ntraaam tsl;oet i Ir,Ivnele+nu.Rwor+ ,b[nr— W.'.r—v 157 aryler [�RR[N MCOJ,.t C+iY.a MWDW). 1•e'p•115 WIRE SIkE CALCULATION BRAN CNCI RCUff R1 MICROINVERTER •'Rs,xv*+a:s'i•'I HOF �'IICROINVERTERSIN BRA NCH CIR{URTOTAL CURREilf,2' 13R--AKERSIZEPER CIRCJIT 5.99'L25=14, 975 MAXIMUM QUTP-IT CURRENT 3. CRCT NOF MICROINVERTERSIN "New main service panel has MICRO INM ERTER t0[.\rIo4 200AMain breaker WNW 6 11,-an:.1-11CN Ixx rS RlLtllll: ir�liifA and has additional 100A space for a +w uac x,m Alternative Energy Input elan:r+(iN(Urrl .I RIx Rr„yrrxrrxs CURRENT which will be used for Solar system" ”+R �xNx{�^I L Over Head UTILITY 599 A CITY OF LA QUINTA e N+rx,i a>t: BUILDING DIVISION nvy„.wSVIM +'rad, [i[nllnr RLVILWLD FOR M MAIN METER ap,u.vnre[+ CODE COMPLIANCE BRANCH CIRCUITTOTAL CVRRENT,3`2,4 MAl(IiAPJf DATE06/16/2022 F, wn-n,.lx+w, CIRCJIT "l.Z5e 7,25 INSTALL 90A 2P CB(PV) $.CRCT INSTALL AT ALTERNATE 2 I 29 125 1 7.25 1 A 29 1 A ENERGYINPUT m BRANCHCIRCUIT#3 Q 200A MAIN C/B M.CROIM ERTER j —"WO, uC0[k:W Te a P OF MI CR OI NVERTERS I N 000 _ \ MAXI -MU❑UEP Jr N PV DISTRBT. PANEL CIRC :Jfr 5.99.1.25=74975 125A, 120/24OV, R. CRCT NEMA 3R 2 S 7-F 1.7.5 T 14.98 7 A (N) GROUNDING ,t ELECTRODE SYSTEM/ I_\ (3) 44 AWG THWN/THWN-2 GEC (1) #8 AWG GND — Ca AT 1 —1 IOLA[IOY :I'.lav .:F:.Y[IP.PEX rS R1L`alR: ITAT fA n•ml. •'.1. ,u m}x'c' J1 150 I'•a LAI a v.in w v e50 ]BOD ...... ............................. . [ntraaam tsl;oet i Ir,Ivnele+nu.Rwor+ ,b[nr— W.'.r—v 157 aryler [�RR[N MCOJ,.t C+iY.a MWDW). 1•e'p•115 WIRE SIkE CALCULATION BRAN CNCI RCUff R1 MICROINVERTER •'Rs,xv*+a:s'i•'I HOF �'IICROINVERTERSIN BRA NCH CIR{URTOTAL CURREilf,2' 13R--AKERSIZEPER CIRCJIT 5.99'L25=14, 975 MAXIMUM QUTP-IT CURRENT 3. CRCT NOF MICROINVERTERSIN BRANCH CIRtUIT70TAICURRENT,1 MICRO INM ERTER t0[.\rIo4 ,'lnrssrc WNW 6 11,-an:.1-11CN Ixx rS RlLtllll: ir�liifA rtcor rar a +w uac x,m .,r.,:[II r: RI,nI. elan:r+(iN(Urrl .I RIx Rr„yrrxrrxs CURRENT NOFMICROINVERTERSIN CIRCJIT ”+R �xNx{�^I L 1 599 1.25 7.49 A 599 A 20 A e N+rx,i a>t: [yt nxi R nvy„.wSVIM +'rad, [i[nllnr I.sxvtl.. ul[I � +--rxrnr[NaxRn, ap,u.vnre[+ IOLA[IOY :I'.lav .:F:.Y[IP.PEX rS R1L`alR: ITAT fA n•ml. •'.1. ,u m}x'c' J1 150 I'•a LAI a v.in w v e50 ]BOD ...... ............................. . [ntraaam tsl;oet i Ir,Ivnele+nu.Rwor+ ,b[nr— W.'.r—v 157 aryler [�RR[N MCOJ,.t C+iY.a MWDW). 1•e'p•115 WIRE SIkE CALCULATION BRAN CNCI RCUff R1 MICROINVERTER •'Rs,xv*+a:s'i•'I HOF �'IICROINVERTERSIN BRA NCH CIR{URTOTAL CURREilf,2' 13R--AKERSIZEPER CIRCJIT 5.99'L25=14, 975 MAXIMUM QUTP-IT CURRENT 3. CRCT CGeneral Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR a R 0 LI P Ara Petrosyan ELECTRICAL 1 -LINE DIAGRAM Ll -JU O O No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Project PV SYSTEM Date PV 04 MAY 06, 2022 Scale AS INDICATED NOF MICROINVERTERSIN BRANCH CIRtUIT70TAICURRENT,1 MICRO INM ERTER RR _A:iER SIZE PER MICROINVERTER CIRCJIT 599.1.25=7.0.875 MAxI:nuM❑ EP JI R. CRCT NnRe4:s ,+.r .,r.,:[II r: RI,nI. elan:r+(iN(Urrl .I RIx Rr„yrrxrrxs CURRENT NOFMICROINVERTERSIN CIRCJIT ”+R �xNx{�^I L 1 599 1.25 7.49 A 599 A 20 A BRAryd{CIRCUIT Irl r,p, CURRENT MICRO INVERTER H QF MICRpIP1VERTER$IN BRANCH CIRCUITTOTAL CVRRENT,3`2,4 MAl(IiAPJf IMNi-A41!R $IZE PER wn-n,.lx+w, CIRCJIT "l.Z5e 7,25 RRENT CURRENT $.CRCT 2 2 I 29 125 1 7.25 1 A 29 1 A 20 A BRANCHCIRCUIT#3 BRANCH CI RC UIT HS M.CROIM ERTER .•..�r...,..:I.: • n �n<x —"WO, uC0[k:W Te a P OF MI CR OI NVERTERS I N BRANCH CIRCUITTOTAL CURRENT, Z` MAXI -MU❑UEP Jr 3R:A<ER5IZEPER CIRC :Jfr 5.99.1.25=74975 CsJRRENT R. CRCT 2 2 S 7-F 1.7.5 T 14.98 7 A S.99 I A 20 1 A BRANCH CIRCUIT#3 CIRCJIT MICROINVERTER OLNPn B. CRCT nRI s¢ulaot'I H OFWCROI INVERTERS IN BRANCH CIRC UIT TOTAL CURRENT, 1' 29 MAXIMUM OUTPJr 3R=AKER SIZE PER CIRCJIT '1.25=i625 C,IRRENT 3.CRCT CGeneral Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR a R 0 LI P Ara Petrosyan ELECTRICAL 1 -LINE DIAGRAM Ll -JU O O No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Project PV SYSTEM Date PV 04 MAY 06, 2022 Scale AS INDICATED MICROINVERTER NnRe4:s ,+.r .,r.,:[II r: RI,nI. elan:r+(iN(Urrl .I RIx Rr„yrrxrrxs sniNv[rtr;xt s.I:,nlly NOFMICROINVERTERSIN CIRCJIT BRANCH CIRtLIITTOTAt CURREINT, 2' 5.99.1.25=14975 Max11.1VM DUlri JT BR FA:CFR 512E PER R. CRCT r,p, CURRENT u•f,w,e asr goo[ N cly ,I.sien wn-n,.lx+w, 7 2 1 599 1 1.25 1 14.48 A 599 1 A 20 1 A w..rtssr.Iav BRANCH CI RC UIT HS tOCarl•?r .•..�r...,..:I.: • n �n<x —"WO, uC0[k:W Te a N pF MICRpINVERTERSIN BRANCH CIRCUITTOTAt CURREP+T,2' BR E 5 q.(ER 12E PER MICRO INV ERTE RMAXIMUM CIRCJIT 5-95' 1.25= 1a,975 OLNPn B. CRCT CURRENT Z 2 1 5.99 1 125 I 1198 I A 5.99 1 A 20 A a �e,twi+r.• tsr;oat i InHnNle+lru.,+oor: xRl.,m[r 4-1 BRANCH CIRCUIT RS W.'.RSSIC71 S7 NOF MICRONVERTERSIN BRANCH CIRCUTTOTALLURREN7.1`24 MICRO INV ERTER 3R _A(ER SiE PER ..,...I[,. wxw*vwu1.8'ow•]iiD 'V1Tr...,. .,rx,u.. nr.x. CIRC:Jfr '1.75-3.625 MAXIMUM ❑UEP JS B. CRCT 1 ' w Iry ,tar: n v.nc w CURRENT RIF lu.f% A Y rrx e[.e v E 1 1 2.9 1 1.25 1 3.63 1 A 2.9 1 A 20 1 A +RIpl.sq;R 1�.V .xr•Ilgt rnnnl� nRAn :I+f DCUI r} xx[nu•rxrrxt xrrlwer-xR s.I:,nll l: FROM l807f T+D PVSUB PANEL r+1;-1 RACEWAY TEMP MRATE FACTO3{max. MORE THAN WIRE SIZE MAXIMUM HFIGHT.`ROM 400 wntinloVs wrrrn: d�vlded AOJI;STEb CONDUCTOR 3CCCa015T FROM NEC gh181ENTTEM FACFOR PER to[arI•?r aB+1ar[W.n[Nn .ID['tn:v(eroC{ C61NTINUDUS Rtl4F(TEMP vrires{# ambient tem, FaGtpr), 1R,6j AMPA CITY, 25.21 D$= FACTOR TABLE NECTASLE 330.lSIhl[2][d1 CCRRENT 39+17-�,6C] of eC•21 0-71 =2S 32.75ZA WIRE5 31615Ih116 wYl+rrl� z1• iNl� w,,ll, 18.50 -1 W..I 186 1 011 1 Xfl A 1 5 0.W I 3L7S A Id'g1VG 0.71 FROM PV SUB PANEL T4 MAIN PANEL - �eswai e:<• --I R-Wlil�<x's. ron w.I.mwlr+iai N TONVERTE 5 FROM AIi TEPo1P_DERATE FACTOR 1091 AT THE WIREKE AMBEN7TEM CONSIDER CONTINUOUS, .LRUI LH M.{RDINMERT Ir11CROINVERTER5, 9'S.99M'29• 65.51 WALL OFTHE BiIILD NGI. B18>?7;10.91= FROMNEC FACTOR PER Sr.:1Ns7 wxlslrepC'trttI.I'n»•9V WL ,,_r,[,.r•ar.u< . . •. ERY '1.75=$1.9A 65.511 908 TABIE NEC TA 61E 111 411 '” I.0 ILlt. .i ..VOW, ...... }D.. ..v Iol+F I.— a v�ar +r.e v ..,......,. 13 13 ........ F5. 5,99,28 —65-5 IT A 65,51 1,25 ....,. w_ ..... 81.89 A 57,9 U91 84,94 d 318151 h116 -' 4AWG 318 ]St h](2)t a} 0,41 CGeneral Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR a R 0 LI P Ara Petrosyan ELECTRICAL 1 -LINE DIAGRAM Ll -JU O O No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Project PV SYSTEM Date PV 04 MAY 06, 2022 Scale AS INDICATED 690.56 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LL /_1101 SERVICE METER I CEC 690.41(A) I WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. HOTOVOLTAIC SYSTEM DISCONNECT AC OUTPUT CURRENT - 65.51 AMPS OPERATING VOLTAGE 240 VOLTS to 75 above the floor or grade !I to center of performance meters AC DISCONNECT --- METER O SERVICE — OFF CEC 5 WARNING RATED OUTPUT CURRENT 65.51 AMPS AC NORMAL OPERATING VOLTAGE 240 VOLTS CEC 705.12(B)(3) WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE 705.12.(B)(2)(3)(b) WARNING PHOTOVOLTAIC SYSTEM - DO NOT RELOCATE THIS BREAKER This lable is to be located adjacent to the PV breaker WARNING DO NOT TOUCH TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SYSTEM LABELING DETAIL PHOTOVOLTAIC REQUIREMENTS PER CALIFORNIA ELECTRICAL CODE ARTICLE 690 WARNING: THIS EQUIPMENT FED BY MULIIPLE SOURCES. Solar Source Only TOTAL RATING OFALL OVERCURRENT DEVICES No Other Loads in EXCLUDING MAIN SUPPLY OVERCURRENT This panel DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC 690.13(8) PHOTOVOLTAIC PV SUB PANEL SYSTEM DISCONNEC (if applicable) FIRE DEPARTMENT REQUIREMENTS IIIIIIIIIIIIII■�� Y COMBINER PANEL BOARD CEC 690.13(B) CEC 690.13(B) WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. INVERTER PHTVOLTAIC I I SYOTOM D SCOP (if applicable) DC DISCONNECT RAPID SHUTDOWN (if applicable) I OFF WARNING ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated. 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to W. V -3b, c" of this requirement. c. Inverters are not required to have caution markings 1. Marking is required on all interior and exterior DC conduit, raceway, enclosures, cable assemblies, and junction boxes, combiner and disconnects. 2. The materials used for marking shall be reflective, weather resistant material suitable for the environment. Minimum 3/8" letter height; all upper case letters Arial or similar font; Red background with Wight lettering. 3. Marking shall contain: WARNING: PHOTOVOLTAIC POWER SOURCE. 4. Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location were the disconnect is operated. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TLI RN RAPID SH UTDOW N SWITCH TO THE -OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. FIGURE 690.561C)111(a I Label for PV Systems that Shut Down the Array and the Conductors Leaving the Array. WARNING: PHOTOVOLTAIC POWER SOURCE COMBINER / I I I JUNCTION ARRAY — BOX WARNING DO NOT TOUCH TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CEC 690.53 Marking shall be placed on interior and exterior DC conduit, raceways, enclosures 264 V and cable assemblies every 10 ft (3048 AAXI MUM CIRCU IT CU R RENT18.60 A mm) within 1 ft (305 mm) of turns or bands and within 1 ft (305 mm) above and below OF penetrations of roof/ceiling assemblies, CONTROLLERwalls or barriers. FIR DC -TO -DC CONVERTER IF IN STALLED I WARNING PLAQUE CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE X06/16/2022 In JF SERVICE POINT & INVERTER TYPE: Micro SOLAR PHOTOVOLTAIC CGeneral Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR a R 0 LI P Ara Petrosyan SYSTEM LABELING DETAIL C C 0 No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Project PV SYSTEM MAY 06, 2022 P V 05 Scale AS INDICATED QUICK MOUNT ATTACHMENT DETAILS ITEM I DESCRIPTION ENO. ............ ...............,....,�.... ,.,...�. 3 WASHER, EALING, el18"IDX 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5116' x 4", 18-888 1 -5 STRUCTURAL SCREW, QMPV, T-3 HEX WASHER HEAD, 6110"X4-112", 1 ' y^� 18-688 �/3��� STRUCTURAL l SCREW AVAILABLE ON QMLM-ST VERSIONS ONLY —.83 73 (.75) '.93) IE i— 3.35 1 2.2t— J QMLM-ST 5/16" SS LAG BOLTS W/2.5" t J AVAILABLE IN MILL, AND BLACK FINISHES FQuick Mount PV F.QMLM & QMLM-ST: L -MOUNT, 2-1/16" SLOT FAST JACK ATTACHMENT DETAILS W8- X 314' 11 3I8" SS 5/16"SS Lag Bob Mln 2.5" O Embetl'mto framin Member 7 1 La er of RAFTER Tmgaage Pae �FjlHA&� C 84486 T CNtI- 9 OFC EXP. 09/30/2023 NnTF• MAXIMI IM ATTAC:HMFNT ni.gTANC:F R,-n- :11-9191 - '2111aA10 OIlMftl hod I - - I -a ri o' P�� ' 1-■_ I�IIIa111�I111gp ATTACHMENTS I-gI-I Materials CITY OF LA QUINTA ORION RAIL BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE ATEO6/16/2022By ,,,06/16/2022,y— TORCH DOWN SHINGLE Materials Amp/ Q.-ty Materials Q: t ARRAY DETAILS NUMBER OF MODULES NUMBER OF MODULES 9 34 Trunk Cables - Portrait 34 so.F HM-1500,HM-700 13 Tbolt 34 LBS Power Optimizer 1 0 Roof Attachments - Qbolt 51 W AC Disconnect RACKING WEIGHT 95.2 LBS Rails 164" 17 d4. PV Breaker 9dA 1 Avid clamps 66 > Quad Breaker NO LBS/SQ-F End Clamps 17 WEIGHT PER SQ FOOT 2.69 Polaris connection NO L8S Splice Bar 6 - [Performance Meter NO Ground Lugs 3 PV Sub Panel 1125AI 1 lChern Curbs If flat roof 51 TORCH DOWN SHINGLE General Notes LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR a R 0 U P Ara Petrosyan /��p ATTACHMENT LAYOUT No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Project PV SYSTEM MAY 06, 2022 )PV 0 6 Scale AS INDICATED ARRAY DETAILS ARRAY DETAILS NUMBER OF MODULES 9 ARRAY SQUARE FEET 212 so.F NUMBER OF MODULES 34 ARRAY SQUARE FEET 843 so.F MODULES WEIGHT LBS NUMBER OF MOUNTS 16 MODULES WEIGHT 1,738.9 LBS NUMBER OF MOUNTS 70 RACKING WEIGHT 95.2 LBS WEIGHT PER ATTACHMENT 35.7 LBS RACKING WErHT 359.8 LBS WEIGHT PER ATTACHMENT 30.8 LBS ;4752 INVERTERS WEIGHT NfA LBS WEIGHT PER SQ FOOT 2.69 LBS/SQ-F INVERTERS WEi--+ff NfA LBS WEIGHT PER SQ FOOT 2.69 LBS/SQ.F TOTAL WEIGHT 571.4 L8S TOTAL WEIGHT 2.158.7 LBS ROOF SPECS MODULE SPECS ROOF SPECS MODULE SPECS RAFTER SIZE 2 x 6 LA Solar 450 450 Watt RAFTER SIZE 2 x 6 LA Solar 450 450 Watt 0 C DISTANCE 24" MDDULEWIDGHT 52.9 LISS 0 C DISTANCE 24" MWIJLEVLEtGHT 52.9 LBS ROOF WTERIAL Torch Down MKHDULE LENGTH 82.3 Inch ROOF WTERIAL Shingle MODl1LE LENGTH 82.3 Inch SLOPE OF ROOF 4 1 Deg MODULE 1AADTH 41.3 Inch SLOPE OF ROOF 12 1 De MODULE VADTH 41.3 Inch NOTES NOTES ROOF TYPE 1 layer of Torch gown ROOF TYPE 1 Layer of Shingle ATTACHMENT TYPE Fast Jatk ATTACHMENT TYPE 4uick Mount LM MA>e ATTACHM DISTANCE 6 Feet MAX ATTACHM DISTANCE 6 Feet INVERTER TYPE HK4-1500,HM-760 INVERTER TYPE HNL1500,HM-700 MODULE TYPE L A Solar 450 MO D D LE TYPE LA Solar 450 PERFDRMANCE METER No PERFORMANCE METER No RACKING Orion RACKING Orion General Notes LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR a R 0 U P Ara Petrosyan /��p ATTACHMENT LAYOUT No. Revision/Issue Date Designed By: Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Project PV SYSTEM MAY 06, 2022 )PV 0 6 Scale AS INDICATED General Notes 14 The World's Safest hoymiles CONTRACTOR: Splpr solution far you and your familyLA :1fivo.miles Solar Group Model HM•1000N HM-120ON HM 1500N16238 B Raymer St., TOATE Input Dmm4Dcr Van Nuys, CA 91406 r—rur,aalm9dlap"Ka"Iwl Jtll'-?,n 74r�36n Vx),-Vrf y A.&I. vmpatlhWty 6o9nprTzralwmxpw :W 9ti e< 6aae1r.T2cYPv4rcaaed Phone: (818) 373-0077 lo,az— WIFvnihmc 2. M 21,98 29-0 M,49 LIC TYPE: C-46, C-10, C-39 s &an -m vahopeNI 22 2z 22 Oyvlplr�p W1iW9 iz'W R7 16-69 16-60 16-60 Mmn . rico vpl[oPa M. W w 60 Lic # 974115 Mm6n.im l -W civ MIN 4.10.5 i-15 4.11.3 ■ I%tput 70[o IA(:) Peakau[purpmve3[7M BOW 1260 T200 .500 '.550 Z: WY,vim'an.Yc ama>F pax4r NN 9SN _� Tar *cv ,2f6 99 IkNnrm c3nYwu, c3�.3 turas lA 5.99 CA: S 555 5- 599 4 2rdxn.p64' �' _'m.�' 2rg1 116 Mnnlid alto -a wllrlt]>Ii�iya [V; ��' ' LASOLAR N."imEffap—yjrmhedul. 6[4'55-65' 61115565' 60/55-65' G R O U P 4=0.99 Calculi 4Woe'odl -099 dowll Pow ioc..w lodjis beJ 13,551nadr¢.-ae5laggng 285 hodrg.-.0�h0P'V 0.851eodrg...065 e.} TutdID i-icdl6:piror •6t "% 61 Ara Petrosyan l MOWm,m imus pert N' 1 5 5 5 e 2 y TZ-2� Eff.. Cleney ""' LEC pear eTnenry 95.'ft 967015 M.]m6 HM-100fl N11200N11500N erki—N 9G5 % LEC 2.w; tied! ef 'A 96.50% .50.7: The Best in its Classr The Milroinverter %,MaA MP TeIllrlcw:y o9An 90 gip{ aceta, with reactive power Control for 4 solar panels Ka, �^,—mrewrallcn:mw9 Me tion Cal Data Amhlenl Tenpe—+up64C1 -w•-65 Highlights er,enssrs[wA mml M.,76y 3S • E65y In51a11atln11,Just plug and play weipet 41,131 s.fs lincl�drq x.s2m ■c cavrel Entl —ratty] G —or NEW 4IM7; • Eater mai as Leona For stranger comm an icatl on with OT[1 coaling No,-ol camectmn - Ns lone • Power fact or [adj us to b l e] 0. AS leadi ng- -.-0-85 1agg Ing Feotur6s • The highest power de nslty micro l n vert at c the market 2 -6c -n iWr—, N-fnerd�c) • Campiia nI. with CA Rule 21 & U, S. NEL 2070/2017 690.12 ra old shutdvwa wrilwing lip ,. 26 Yxaa • H1gh re 11 a hl l lty; HE MA(IP67) an C Iasu re; 6000V surge protect tun u, C—p66nte :n. ytre,ur.�,1•t sx CNo:x.�s„*n 1,+a al. a'ccninu.vur,u �[cx'e— _ Smarter MarePowerful More Reliable Pv 1&pki 5lu:dpvwl w6if��bN Pa �`s°'t B0011 uc,mw x� rm�d s,n,.n awc uxw - 5alesOhoymlies.corn ® +86.571.28056191 f* www.hoymffe5.com by miles INVERTER The so of SWolUt on for ypuland your fomlly DATA SHEET Model HM-60ON HM 704N HM -800N In Fur Got. IDC Cv+'nmdv used rmdibp uv"+, M 240-380 7&'> "c 320 -SW WAuk ccnp.tu f h 6pcely rlcm Yimuitc Iota. Y" W,s 6pctia ltre6 W mwwn6 Ytrk pa—Mm vullape-1.. Iv: 49-44 33-t6 35-66 - Sion -v witw. .fV. 22 22 22 r • • • O a•nd'3 vd!ag.' Tao lvl '6-80 16-41) 16-0 'mo," im Pvvr unlnpe IV] 60 do 67 O O Wx— rpo nrnnl i✓,1 21-1 5 2.11.5 2,12.5 Gu'put Dow iAG O O PmkaAautpi—r4vA1 6W 100 Sao _ 6,rmr m�rxnnn 6mtnn 62. 4wv CM 8 69h a6 No. Revision/Issue Date r.la—A+vnuno W at.,wl 2.44 2.84 L9 3.55 s,9 sale H,rnimi oulpL: VOILQOVWp 4v1 24g2n26c1 P]sW29' j1pYn2M' 2CW285' 2130"1264' XWS226' Y T••lol frppy yfryrenal 6arv-65' 61J5r65' 6OV56-65' .r.99 default m"9 da1Wr --aW Mw4 " v.55epdrg..e.as�rg �86mod•g.-0.86opglq caSlemn�p65hpp� Designed By: I3131 +o +Drat TW1104 •3113 d% •9% Nnlls per Oroncl'= 6 S 5 9 5 9 Lfflcie:+cy' Rafik Avagyan HM-60ON1700NI800N CECoetaW.clery 96.7011 95.70% CCL vasgh.d of -i:1—y 95.3014 96.50Y %.53% The hest r}ai5y-chain micrOinverter with fYrn n•wl MWJ c•f ryniv W.W% 90.60% "An reactive power control for 2 solar panels rAgrielepp136er,---p W;Mw) �5e •50 •5C: Project Name and Address Mechoq Cal Outs Highlights Aaei—tem W..—V tIQ-AC^•6s YLVIA KIN 1Nmen6lpr6 2.a wi.3,rm1 250x110x 28 • Eesy 1nst611at1vn,Just plug end play wep!n [Lal s.n 1rrll�ding z 5111 nc came; - External antenna For sr rongf•r comm a n lc atl on with DTD E�—rmng Owdoor N -MA 411671 80080 Vista Grande, • Powe r fat for Eadj us to h I el 0.85 I each ng -1111-0.85 I ag g ing rc-311010 rva1 in 111 mnY.n:,1nn - nn fn•,e • Compliant with CA Rule 21 & D.S. NEC 2014/2017 690.12 rapid Shutdown Fea:pre. La Quinta, CA 92253, USA - H1gh re 11 a In I Ity; NE MA(IP67) an c I osu rl; 6000Y so rge prole et ton unerti:svWn 29CHx atoll bt RFpM-da•1 Wri[arl g th4• V—bfrvp Sntm Prolecl Wif —Y lip 2.a 25 yea's A Safer Smarter More Yvwerfvl More Reliah a Laacliance 13auA.n�Efs 6649iH•rb, U.AA U-kcL 6'L2 Na. M11-., 6ct dy 4 TieC .—An PV SYSTEM am[EGxl65,c M-]+98md51cHwnd R'6crmrn ^ Date MAY 1)6, 2022 J O 7 ;~: salesiHh nymile5-[am +66-577-28Q5fi701*I www-hoymires-Cam .wrn ^� ���'F V'"•'°"•' e'"^""'�^""'°'•"" Scale AS INDICATED General Notes CONTRACTOR: LA Solar Group Hoymiles UL Certificate 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 CRA C" GROUP "CSA GROUP` 3 LASOLAR Certificate: 80017010 Master Contract: 261002 Certificate of Compliance °j = 036 9 Date Issued: 2020-03-12 Ara Petrosyan Certificate: 80017010 Master Contract: 261002 APPLICABLE REOLIIREMENTS CSA -022.2 No. 107.1-16 - Power Conversion Equipment Project: 80036969 Date Issued: 2020-03-12 *UL Std. No. 1741 - Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources (Second Edition, Revision dated February 15, 2018) Issued to: Hoymiles Converter Technology Co., Ltd. No -18 Kangjing Road, Hangzhou, Zhejiang 310015 `Note: Conformity to UL 1741 -Second Edition (February 15, 2018) includes compliance with applicable CHINA requirements of IEEE 1547-2003(R2008). IEEE 1547.1-2005 (R2011) and California Rule 21 and Supplement Attention: Xingu ao Zhang SA. The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' far US only or without either indicator far Canada only. HOYMILES UL CERTIFICATE CHIssued by: Ya of [Ta4o v) Lei, Yang (Jason) Loi C U5 JCD PRODUCTS CLASS - [531109 - POWER SUPPLIES -Distributed Generation Power Systems Equipment CLASS O O CLASS - C531189 - POWER SUPPLIES - Distributed Generation -Power Systems Equipment - Certified to U. S. Nc. RevlsloNlsaue Date Standards Grid Support Utility Interactive Inverter, Model HIM -1500, HM -1500T, HM 1200, HM -1200T, HM 1000 and HM 1000T, TTIM-1500, 1 -]Al- I500N. HILI-1500NT, H?M-1200N, M4 1200NT. H 4-100ON and HM 1000NT. Designed By rack mounted. Rafik Avagyan For details related to rating, size, configuration, etc., reference should be made to the CSA Certification Record, Certificate of Compliance Annex A, or the Descriptive Report. Project Name and Address *Note: This product is PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEG2017 Article SYLVIA KING 690.12 and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 80080 Vista Grande, La Q� uinta, CA 92253, US_J Projec PV SYSTEM 1)-L1507Rav 2019-41-30 Date ^ O /'� MAY 06, 2022 yv� 1.:-I):1) Rev -2019 -o1 -3n P '' .^c J Scale AS INDICATED Peak Power (Pmax) 450W 0 --LA G R Module Efficiency 20.5% lyJ L9 .... � L Maximum Power Voltage (Vmp) 41.00V Maximum Power Current (Imp) 10'98A Open Circuit �Voc) 49.60V Short Circuit Current (Isc) 11.53A Power Tolerance ± 3 % Maximum system 1 5o0V Voltage Nominal Operating Cell 44.4+ 2°C Temperature w * ■ Maximum Series ■ Fuse Rating 20A Cell Type 166x83 mm MONO P€RC Junction Box 1P5F Number of Cells 144 16x12+602) Connector MC4 Weight 24.okg Wire type compatible PV wire Dimension 2109x104Rx40rnm Fire Performance Type 1 � Max Load 54170 Pascals Protection C18S5' Class II (Classified as pef !�C 61940) LA SOLAR ilEMP'ERAWRE CHAR MONO MODULE L5450BL Temp. Coeff. of Isc (TK Isc) 0.04°x/"C Container 40'H0 Temp. Coeff. of Voc (TK Vac) -0.28% 1 "C Pieces per Pallet 26 Temp. Coeff. of Prnax (TK Pmax) -0,37961 "C Pieces per Container 520 Nigh conversion efficiency Excellent loading capability %. A0 h+ll�E Figoy W.IRq,�.n, 18wwrc oM►e..ww,.nq '". Outstanding low irradiation Full black design performance- s �o � 15 as n Less shading effect] Strong physical Property„ ! I I QUALIFICATIONS AND CERTIFICATES I�us iiL11ECb1215, ULIIEC6173(3 �Ih� g I ANTI -PID IEC TS 62804-`I :201 5 C�iFi Pr" _ 5U2D665 C E IS09001, IS014001, IS045001 ,M■ F 4 III Raff1 st.. Yerevan, RA � YYA'�YSYY.Ic15�a�c]["�s"1a,fi�if'�. Lntczrtczk Total Quality. Assured. MODULE CERTIFICATION Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 2104001883HA-001 Original issued. 17 -Jun -2021 Revised. None Crystalline Silicon Photovoltaic (PV) Modules Photovoltaic (PV) Module Safety Qualification - Part 1: Requirements for Construction [UL Brand name 61736-1:2017 Ed.1+R:30Apr20201 Photovoltaic (PV) Module Safety Qualification - Part 1: Requirements for Construction [CSA The product covered by this report are terrestrial used photovoltaic modules which convert C22.2061730-1:2019 Ed -2] SYLVIA KING Photovoltaic (PV) Module Safety Qualification - Part 2: Requirements for Testing [UL 61730- 80080 Vista Grande, 2:2017 Ed. 1+R.30Apr2020] consists of a laminated assembly of solar cells, which are interoonnected with conductive Photovoltaic (PV) Module Safety Qualification - Part 2: Requirements for Testing [CSA Standards) C22.2461730-2:2019 Ed -2] Projec Terrestrial Photovoltaic (Pv) Modules - Design Qualification And Type Approval - Part 1. assembly is sandwiched between a rigid transparent top fro ntsheet and an insulating Test Requirements [UL 61215-1:2017 Ed. 1] Terrestrial Photovoltaic (PV) Modules - Design Qualification And Type Approval - Part 1-1: Date MAY 06, 2022 Special Requirements For Testing of Crystalline Silicon Photovoltaic (PV) Modules [UL Field wiring connections to the module are made via a factory installed junction box with 61215-1-1.2017 Ed.11 Dcscnption Terrestrial Photovoltaic (Pv) Modules - Design Qualification And Type Approval - Part 2' Test Procedures [UL61215-2:2017 Ed. 1] Applicant La Solar LLC Manufacturer 1 La solar LLC Address Raffi 111, Yerevan, 0064 Address Raffi 111, Yerevan, 0064 Country Armenia Country Armenia Contact Garen Asrya n Contact Garen Asryan Phone +37444293999 Phone +37444293999 FAX - FAX - EmailoarenCdllasolarprouo.com Email I a aren (drfasoIarpr222 Go Page 1 of 38 Thin report Is W the exJ sive use ai Inledek's client! and tis provided pursuant to the agreement between Initrtek and its Client ani-lialCS F"ponslbillty and I -ability are limited to the leans wia oonditiona or the agreement Int&tek 05SUMee nO lieblllty tO Wry party. other ligan to the Client In socoddarce WM me agreement For any k s , @"rk a or dan rage xc ioi red by Ow u" or [tris IapcnL Only the client ie autlurlxed la parr lit cupyng a diwjkx tiun or this epurt and then only Ir its entirety. Any use at the mieneK name o< one of da marks for the sale or adverisement of the teatee maEerlal, product or servt must first be approved In writing by Intertek. The oos alions and test results in thls report are mhl arrt only Io vie sample tested This report by imel' does not GrArly that ItW material, product. V service is a has ever peen urxder i Injertak perti Lcir5w pi 9gr am Report No. 210400188SHA-001 La Solar LLC Issued: 17 -Jun -2021 Revised: None 2.0 Product Description I Date Product Crystalline Silicon Photovoltaic (PV) Modules Brand name LA SOLAR The product covered by this report are terrestrial used photovoltaic modules which convert SYLVIA KING elements of the electromagnetic spectrum to DO electrical power. The basic construction 80080 Vista Grande, consists of a laminated assembly of solar cells, which are interoonnected with conductive USA �La matria l such as rlbdons, and encapsulated within an insulating material. This encapsulated Projec assembly is sandwiched between a rigid transparent top fro ntsheet and an insulating PV SYSTEM backsheet. The laminated assembly mostly be supported by an anodized Aluminum frame. Date MAY 06, 2022 ^ Jw0 Field wiring connections to the module are made via a factory installed junction box with Scale AS INDICATED Dcscnption polarized mating cables and connectors. The modules include a weatherproof junction box with mating connectors only provided for field -connection. The modules are manufactured from the factory and shipped fully assembled. An installation manual is provided. The modules must be mounted over a fire resistant roof covering material rated for the application. Internal buss ribbon wires, and cross buss ribbon wires are enclosed within the module front cover and back substrate. Bypass diodes are provided inside the junction box. Modules are intended to be installed in accordance with the National Electrical Code, NFPA 70 and Canadian Electrical Code (CEC) respectively. LS followed by 370, 375, 380, 385, 390. 395 or 400, followed by ST. Models LS followed by 390, 395, 400, 405, 410, 495 or 420; followed by HC. LS followed by 430, 435, 440, 445 or 450; followed by HC. All models have same construction except for the different solar cells used. Models with full size 158.75mm solar cell LS followed by 370, 375, 380, 385, 390, 395 or 400, followed by ST. Model Similarity Models with havled size 158.75mm solar cell: LS followed by 390, 395, 400, 435 or 410, followed by HC. Models with havled size 166mm solar cell: LS followed by 430, 435, 440, 445 or 4517; followed by HC. Model Pmax[W) Voc (V) Isc (A) imp Vmp ystern voltage MSF (t3%) (t3%) (t3%) (V) (A) V (A) LS370ST 370 48.50 9.96 9.47 39.10 1500 20 LS375ST 375 48.60 10A1 9.52 39.40 1500 20 LS380ST 380 48.70 10.06 9.57 39.70 1500 20 LS365ST 385 48.90 10.11 9.63 40.00 1500 20 LS390ST 390 49.00 10.16 9.68 40.30 1500 20 LS395ST 395 49.20 10.21 9.73 44.60 1500 20 LS400ST 400 49.50 1026 9.78 40.90 1500 20 LS390HC 390 48.30 10.30 9.70 4025 1500 20 Ratings LS395HC 395 48.45 10.40 9.81 40.35 1540 20 LS400HC 400 48.60 10.50 9.90 40.45 1500 20 LS405HC 405 48.75 10.60 1 10.00 40.55 1 1500 20 LS410HC 410 48.90 10.70 10.10 40.65 1500 20 LS415HC 415 49.00 10.80 1020 40.70 1500 20 LS420HC 420 49.10 10.90 10.30 40.80 1500 20 LS430HC 430 48.80 11.24 10.66 40.30 1500 20 LS435HC 1 435 1 49.00 11.31 10.74 40.50 1500 20 LS440HC 440 1 49.20 11.39 10.82 40.70 1500 20 LS445HC 445 1 49.40 11.46 10.90 40.80 1500 2] LS450HC 450 49.60 11.53 10.98 41.,)o 1500 20 Front side design load = 3600 Pa, tested at safety factor 1.5. Back side design load = 1600 Pa, tested at safety factor 1.5. Proctection Class- Class IT (Classified as per IEC 61140) Other Ratings Fire Performance. Type 1 Application altitude up to 2000m. Pollution degree: 1 Maximum system voltage: 1500V E9 18.3 15 ixr,lar-2pQ 11 Mandatory General Notes LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 LASOLAR Ara Petrosyan MODULE CERTIFICATION No. I Revision/Issue I Date Designed By Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, Quinta, CA 92253, USA �La Projec PV SYSTEM Date MAY 06, 2022 ^ Jw0 - I Scale AS INDICATED RACKING SPECS General Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 *SCI_AR RACKING OSOLAR RACKING VENUS SYSTEM. 0 We Make Solar Installation VENUS SYSTEM. 0 We Make Solar Installation j f LASOLAR a a 0 u a Residential Roof System "Patent Pending Residential Root System `Patent Pending Ara Petrosyan J Grounding Mid Clamp C n R COMPOSITION SHINGLE STMOOff FLAT TIL SPANISH TILE Rails and Clamps GmundingSNlee Bar Smart Ground Cllp Product Detail: Ole RACKING SPECS Orion's Venus System is the most versatile system available. Ideal for Residential roof tops, our rail system is suitable for composition shingle, flat or Spanish tile, and even metal roofs- The Venus system has been install on pitched roofs and even flat commercial Orion Rails Grounding Splice Bar Grip Mid Clamps End cIMM roofs- We offer a number of attachments: standoffs, flashing, and adjustable tilts, all for your specific solar needs. Made from 6005 Aluminum. these rails are Our splice bars connect two Cur Md Clamps not only mount tura We can provide either Grounding End the baNborle of the system. Available in rails together and continues the MITI, Clear kudized or Black AnedLed, grounding for an easier Installation. adocent modules, but also have Integrated grounding iron both Clamps or thNersal End clamps for your solar needs. m Aluminum 6005 Roof Attachments modules to Me rails. • Available in dear or black finish • Integrated and simplified grounding • Complete roof attachment kitsDate LL O O No. Revision/Issue • Code compliant across the US "� • Fast and precise installation with pre -assembled and minimum quantity of components I Composition Shlnoje StagdoffsTile AvaliabIs in the economy or the SMART Available in 3" or 6", raise your edition, this wt provides a three-part modules to a higher standard. Hooks Metal Roo} Available for Flat or Spanldh Tl Is, these Penetate the rafter with our hooks mount to rafters without the need hanger bolts, or clamp the Designed By Rafi k Avagya n waterproofing system that will mount VI -system. to drill into the tlle. seams with our standing learn clamps. \Grounding and Accesories Project Name and Address 15 Year Warranty Twice the protection offered by competitors- Fire Rated Class A re -Assembled Type i and Type 2 1 r;bdr 5avingwv 0 � � � ` SYLVIA KING — � � 80080 Vista Grande, Integral Grounding Streamlines equipment grounding. UL Listed SRA UL2703 Buy Amer !can Act Compliant Adjustable Lens Grounding Luo These legs can adjust your Complete the grounding Micminverter-AttacUments Mount and ground your Wire �Giips Available in StainOss Steel or Black �La Quinta, CA 92253, USA Pro ec UL1703 tilt to 10-60 degrees. Warks with our smart ground clip. miereinvefter to our system with Plastic for ail your wire management PV SYSTEM easily with our system- our Star washer Assembly. needs. Data S 11 MAY 06, 2022 . � Scale AS INDICATED 020t5 prion Solar Racking, www.orionracking-CDM T (310) 4Cg-4616 F:(310)409-4617 0 02G15 Orion Solar Packing, wAw.ohnnrackirgccam T: (310) 409-4616 r:(310)409-4617 # RACKING CERTIFICATION ATTACHMENT SPECS General Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., E °��= a Van Nuys, CA 91406 CERTIFICATE OF COMPLIANCE a Phone: (818)373-0077 3 E 4 0 -2 T VLIC TYPE: C-46, C-10, C-39 Certificate Number 201506133-E469627 _ ___ - " " a s v Lic#974115 ro Report Reference E469627-20150303 _ F a d u E Issue Date 2015-JUNE-03 l " E L I « „ E a r LASOLAR E Issued to: Orion Solar Racking - r a a d 2917 Vail Ave Ara Petrosyan cri Commerce CA 900405 v= r � E ti r2 c 7- ° v o L H s � N ri This is to certify that Mounting Systems, Mounting Devices, Clamping Devices = a t a ❑ c � �� �Q,a rtL° E � representative samples of and Ground Lugs for Use with Photovoltaic Modules andr - _, w p m T N o Panels a - - a ` .T _ o USL - VenusSystem-1 The Venus System 1 achieved a system fire classification y Q .4 a N m= ; i" o g `A' for a steep-sloped roof when tested in combination with = a A . Type 1 & Type 2 modules. The system fire test method - was in accordance to Standard for Safety for Fiat-Plate - ¢ ■ • • Photovoltaic Modules and Panels, UL 1703, 3rd Edition, dated May 20, 2014. RACKING CERTIFICATION s AND ATTACHMENT Have been investigated by UL in accordance with the a� SPECS =u Standard(s) indicated on this Certificate. R Standard(s) for Safety: UL 2703, "Outline of Investigation for Mounting Systems, s " $ 1. Win �Q Mounting Devices, Clamping/Retention Devices, and a Ground Lugs for Use with Flat-Plate Photovoltaic Modules a $ a 4 gel and Panels." m ti s Additional Information: See the UL Online Certifications Directory at ' e o A 1 ti No. Revision/IssueDate wRL 7 ww.ui.comldatabase for additional information p c ` C ' �g4 s £' s Designed By O `s� nE Only those products bearing the UL Certification Mark should be considered as being covered by UL's Zs = Q Certification and Follow-Up Service. s o �P �g Rafik Avagyan oras Look for the UL Certification Mark on the product. l" = . J� T 8 Project Name and Address xR mE s>a � m .aa'€91a u 3 O g d s SYLVIA KING G� 3.c � � € E 80080 Vista Grande, OmwMahmn"I�Am-stantCnelEn�or.OWb,llnsWO— and F.� �.s a g� a_s 9 La Quinta, CA 92253, USA UL LW �r= p• [m ago Any inlemlaGen anE Deeumenution irwo3ring VL Meek services att pmriEetl on bele• of LL LLC (u!j of anyawwelee li[eniee el w For queslmre, please i+ 9E a �' £ E 1 Project canted a total u� c�smmec Sam Rep as tiv a< ntm�ird.eomrabartovincanmsr .3 L = m = PV SYSTEM _ r O Efb n 5$ Page 1 of 1r L Date S 12 L£ m! o S E g MAY 06, 2022 l Z o J E E E $ p E P ro ScaleAS INDICATED SIEMENS MAIN PANEL WITH SOLAR INPUT 100A Max Solar Input Meter -Load Center Combinations EUSERC and CA Title 24 Compliant, 1 -Phase, 3 -Wire, 120/240V AC COMING SUMMER 2014! This innovative design solution, offered only by Siemens, Coming this summer, Siemens line of feature rich "solar eliminates the need to de -rate the main breaker and take up valuable load side spaces by backfeeding on to the bussing. Ready" meter -load center combination devices will feature Currently this feature rich line of meter -load center the industries first dedicated 1 00A max alternate energy combinations can accommodate up to 60A solar input. input. These devices feature a dedicated alternative energy input so power feeds ahead of the service disconnect on the load side of the meter socket. Dedicated Adjustable flush raiis 100 Amp Max Alternate Energy Input Raised neutral bar featuring instawire OH)UG design for ease of Feed r install t � Raised basepan for ease of wiring 200 Amp Main Disconnect I � I Side hinged door EUSEFIC &CA Tide 24 Compliant Meter-LDad Center Combination, Dr Amp with Afternate Energy Input& Full Load Center Width 4 MC304OS12DOSC 30 40 35.7 21 5.1 WI -IG None Surface ECMC5J 100A MC404CS1200SC 40 4G FUSERC aCk-ritte, 24 Compliant Meter -wad center combination, 200 Amp with Aftemate Energy Input &Between Studs Width Cslde-�Slde construction) MC0816512005CT '8 16. '40.7 14.5 7.1 OHfUG None Surface ECMC5J 1o0A MC244ZS12DOSC surface 24 42 40.7 14.5 7.1 OHIUG None ECMC5J 100A MC244251200FC Flush ELISEI�: &CAritle 24 Compliant Meter -Load Center Combination, 0t Amp with Alternate Energy Input Overhead Feed Only MC204051200SZ :24 44 32.7 1.4.4. 4.3 OH None Surface EC6590-121 100A 7 General Notes CONTRACTOR: LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Lic # 974115 3 LASOLAR Ara Petrosyan SIEMENS MAIN PANEL WITH SOLARINPUT O O O O No. R-isioNlssue Date Designed By Rafik Avagyan Project Name and Address SYLVIA KING 80080 Vista Grande, La Q� uinta, CA 92253, US_J Projec PV SYSTEM Date S 13 MAY 06, 2022 Scale AS INDICATED 5/9/2022 LA Solar 16238 B Raymer St Van Nuys, CA 91406 Attn.: To Whom It May Concern re job: SYLVIA KING 80080 Vista Grande, La Quinta, CA 92253, USA Current Renewables Engineering BSOL2022-0212 CITY OF LA QUINTA BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE —106/16/2022 By 12.35kW PV SYSTEM The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Desien Criteria: Code: 2019 CBC ASCE 7-16 Live Load: 20 psf Ult Wind Speed: 130 mph Exposure Cat: C Ground Snow: 0 psf Current Renewables Engineering Inc. Professional Engineer projects@creng.solar Min Roof Snow: NA Iv1 2r C 84486 �9T CNIt 7F CAL1�� EXP. 09/3012023 1960 Chicago Ave, Suite D15, Riverside, CA 92507 www.currentrenewableseng.com 1 951.254.5655 INTEGRITY PROFESSIONALISM , CUSTOMER EXPERIENCE Job Code: SYLVIA KING Current 2 of 6 Engineering Roof Properties: Roof Type = Roof 1 Roof 2 Flat Material Shingle Roof Pitch (deg) = 4 12 Mean Roof Height (ft) = 13 13 Attachment Trib Width (ft) = 2.75 1.65 Attachment Spacing (ft) = 6 6 Framing Type = Rafter Rafter Framing Size = 2x6 2x6 Framing OC Spacing (in.) = 24 24 Section Thickness, b (in.) = 1.5 1.5 Section Depth, d (in.) = 5.5 5.5 Section Modulus, Sx (in .^3) = 7.6 7.6 Moment of Inertia, Ix (in .^4) = 20.8 20.8 Framing Span (ft) = 9 8 Deflection Limit D+L (in.) = 1.8 1.6 Deflection Limit S or W (in.) = 1.20 1.07 Framing Upgrade = Adequate Adequate Sister Size = NA NA Wood Species = SPF #2 SPF #2 Wood Fb (psi) = 875 875 Wood Fv (psi) = 135 135 Wood E (psi) = 1400000 1400000 CD (Wind) = 1.6 1.6 CD (Snow) = 1.15 1.15 CM=Ct=CL=C;= 1.0 1.0 CF = 1.3 1.3 Cf. = 1.00 1.00 Cr = 1.15 1.15 F'b_wind (psi) = 2407 2407 F'b_snow (psi) = 1730 1730 F'v_wind (psi) = 216 216 F'v_snow (psi) = 155 155 M_alIowa ble_wind (Ib -ft) = 1517 1517 M_alIowa ble_snow (Ib -ft) = 1090 1090 V_allowable_wind (Ibs) = 1188 1188 V_allowable_snow (Ibs) = 854 854 E' (psi) = 1400000 1400000 Load Calculation: 1960 Chicago Ave, Suite D15, Riverside, CA 92507 wvjw.currentrenewableseng.com 951.254.5655 INTEGRITY PROFESSIONALISM CUSTOMER EXPERIENCE Job Code: SYLVIA KING Current 3 of 6 - Engineering Dead Load Calculations: Panels Dead Load (psf) = 3.0 Directionality Factor, kd = 0.85 Roof 1 Roof 2 Roofing Weight (psf) = 2.0 3.0 Decking Weight (psf) = 2.0 2.0 Framing Weight (psf) = 0.9 0.9 Misc. Additional Weight (psf) = 1.0 1.0 Existing Dead Load (psf) = 5.9 6.9 Total Dead Load (psf) = 8.9 9.9 Wind Load Calculations: Ultimate Wind Speed (mph) = 130 Directionality Factor, kd = 0.85 Topographic Factor, kzt = 1.0 Velocity Pressure, qz (psf) = Roof 1 Roof 2 Velocity Press Exp Factor, kz = 0.85 0.85 Ground Elevation Factor, ke = 1.00 1.6 Velocity Pressure, qz (psf) = 31.2 31.2 Array Edge Factor, yE = 1.25 2.5 Solar Equalization Factor, ya = 0.70 0.70 External Pressure Up, GCp_1 = -1.6 -2 External Pressure Up, GCp_2 = -2.15 -2.6 External Pressure Up, GCp_3 = -2.9 -3.1 External Pressure Down, GCp = 0.25 0.6 Design Pressure Up, p_1 (psf) = -43.7 -54.6 Design Pressure Up, p_2 (psf) = -58.7 -71.0 Design Pressure Up, p_3 (psf) = -79.2 -84.7 Design Pressure Down, p (psf) = 16.0 16.4 Hardware Checks: Lag Screw Checks: Roof 1 Roof 2 Ref. Widthrawal Value, W (Ib/in) = 205 205 (CM = Ct = Ceg = 1.0) CD = 1.6 1.6 Adjusted Widthrawal Value, W' (Ib/in) = 328 328 Lag Penetration, p (in.) = 2.5 2.5 Allowable Widthrawal Force, W'p (Ibs) = 820 820 Applied Uplift Force (Ibs) = -668 -489 Uplift DCR = 0.81 0.60 1960 Chicago Ave, Suite D15, Riverside, CA 92507 wvjw.currentrenewableseng.com 951.254.5655 INTEGRITY PROFESSIONALISM CUSTOMER EXPERIENCE Current Engineering Ref. Lateral Value, Z (Ibs) = 250 250 (CM =Ct=Co=Ceg=1.0)CD= 0.9 0.9 Adjusted Lateral Value, Z' (Ibs) = 225 225 Applied Laeral Force (Ibs) = 3 6 Angle of Resultant Force, a (deg) = 90 89 djusted Interaction Lateral Value, Z'a (Ibs) = 820 820 Lateral DCR = 0.00 0.01 Roof Framing Checks: 1411 1420 Force Checks: 627 710 Allowable Moment (Ib -ft) = Roof 1 Roof 2 LC1: D+S 1188 1188 Applied Moment (Ib -ft) = 303 255 Applied Shear (Ibs) = 135 128 Allowable Moment (Ib -ft) = 1090 1090 Allowable Shear (Ibs) = 854 854 Moment DCR = 0.28 0.23 Shear DCR = 0.16 0.15 LC2: D+0.6W Applied Moment (Ib -ft) = 886 727 Applied Shear (Ibs) = 394 364 Allowable Moment (Ib -ft) = 1517 1517 Allowable Shear (Ibs) = 1188 1188 Moment DCR = 0.58 0.48 Shear DCR = 0.33 0.31 LC3: D+0.75(S+0.6W) Applied Moment (Ib -ft) = 740 609 Applied Shear (Ibs) = 329 305 Allowable Moment (Ib -ft) = 1517 1517 Allowable Shear (Ibs) = 1188 1188 Moment DCR = 0.49 0.40 Shear DCR = 0.28 0.26 LC4: 0.6 D+O.6 W Applied Moment (Ib -ft) = 1411 1420 Applied Shear (Ibs) = 627 710 Allowable Moment (Ib -ft) = 1517 1517 Allowable Shear (Ibs) = 1188 1188 Moment DCR = 0.93 0.94 Shear DCR = 0.53 0.60 1960 Chicago Ave, Suite D15, Riverside, CA 92507 wvjw.currentrenewableseng.com 951.254.5655 INTEGRITY PROFESSIONALISM CUSTOMER EXPERIENCE Job Code: SYLVIA KING 4of6 Deflection Checks (Service Level): LC1: D+L Current � Engineering Roof 1 Roof 2 Deflection (in.) = 0.23 0.15 Deflection Limit (in.) = 2.07 1.84 Deflection DCR = 0.11 0.08 LC2: S Deflection (in.) = 0.00 0.00 Deflection Limit (in.) = 1.38 1.23 Deflection DCR = 0.00 0.00 LC3: W (Down) Deflection (in.) = 0.20 0.13 Deflection Limit (in.) = 1.38 1.23 Deflection DCR = 0.15 0.11 LC4: W (Up) Deflection (in.) = -0.56 -0.44 Deflection Limit (in.) = 1.38 1.23 Deflection DCR = 0.40 0.36 Seismic Check: Existing Weight: Wall Weight (psf) = 17 Tributary Wall Area (ft) = 1200 Total Wall Weight (Ibs) = 20400 Roof Weight (psf) = 6 Roof Area (ft) = 3500 Total Roof Weight (Ibs) = 20809 Total Existing Weight (lbs) = 41209 Additional PV Weight: Total Additional PV Weight (lbs) = 490 Weieht Increase: (Existing W + Additional W)/(Existing W) = 101% Job Code: SYLVIA KING 5of6 The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at 1960 Chicago Ave, Suite D15, Riverside, CA 92507 wvjw.currentrenewableseng.com 951.254.5655 INTEGRITY PROFESSIONALISM CUSTOMER EXPERIENCE Job Code: SYLVIA KING ,.�.� Current 6of6 Engineering time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. 1960 Chicago Ave, Suite D15, Riverside, CA 92507 wvjw.currentrenewableseng.com 951.254.5655 INTEGRITY PROFESSIONALISM CUSTOMER EXPERIENCE